Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “system calibration”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 847 records · Page 47

Optical Interferometric Micrometrology

Resolutions in angstrom and subangstrom range sought for atomic-scale surface probes. Experimental optical micrometrological system built to demonstrate calibration of piezoelectric transducer to displacement sensitivity of few angstroms. Objective to develop relatively simple system producing and measuring translation, across surface of specimen, of stylus in atomic-force or scanning tunneling microscope. Laser interferometer used to calibrate piezoelectric transducer used in atomic-force microscope. Electronic portion of calibration system made of commercially available components.

Abel, Phillip B.↗

Remote Pulsed Laser Raman Spectroscopy System for Detecting Qater, Ice, and Hydrous Minerals

For exploration of planetary surfaces, detection of water and ice is of great interest in supporting existence of life on other planets. Therefore, a remote Raman spectroscopy system was demonstrated at NASA Langley Research Center in collaboration with University of Hawaii for detecting ice-water and hydrous minerals on planetary surfaces. In this study, a 532 nm pulsed laser is utilized as an excitation source to allow detection in high background radiation conditions. The Raman scattered signal is collected by a 4-inch telescope positioned in front of a spectrograph. The Raman spectrum is analyzed using a spectrograph equipped with a holographic super notch filter to eliminate Rayleigh scattering, and a holographic transmission grating that simultaneously disperses two spectral tracks onto the detector for higher spectral range. To view the spectrum, the spectrograph is coupled to an intensified charge-coupled device (ICCD), which allows detection of very weak Stokes line. The ICCD is operated in gated mode to further suppress effects from background radiation and long-lived fluorescence. The sample is placed at 5.6 m from the telescope, and the laser is mounted on the telescope in a coaxial geometry to achieve maximum performance. The system was calibrated using the spectral lines of a Neon lamp source. To evaluate the system, Raman standard samples such as calcite, naphthalene, acetone, and isopropyl alcohol were analyzed. The Raman evaluation technique was used to analyze water, ice and other hydrous minerals and results from these species are presented.

Garcia, Christopher S.↗

Smart Sensor Node Development, Testing and Implementation for ISHM

A main design criterion for a robust Integrated Systems Health Management (ISHM) system is summed up best by the statement "No data is better than bad data". Traditional data acquisition systems are calibrated in a controlled environment and guaranteed to perform bounded by their tested conditions. To successfully design and implement a real world ISHM system, the data acquisition and signal conditioning needs to function in an uncontrolled environment. Development and testing focuses on a design with the ability to self check in order to extend calibration times, report internal faults and drifts and notify the overall system when the data acquisition is not performing as it should. All of this will be designed in a system that is flexible, requiring little redesign to be deployed on a wide variety of systems. Development progress and testing results will be reported.

Mengers, Timothy↗

Vicarious Calibration of the Long Near Infrared Band: Cross-Sensor Differences in Sensitivity

Numerous assumptions and approximations are employed when translating satellite-derived radiance to surface remote sensing reflectance (RRS) for ocean color applications. Among these is the vicarious calibration coefficient (g) of the “long” near infrared band (NIRL) used for atmospheric correction. For this band, the prelaunch calibration has always been deemed sufficient [thus g(NIRL) = 1.00] as long as other bands are vicariously calibrated. Recent research, however, suggests that Moderate Resolution Imaging Spectroradiometer (MODIS)/Aqua RRS time series is quite sensitive to g(NIRL) (and associated vicarious gains in other bands). In this work, we assessed the sensitivity of Visible Infrared Imaging Radiometer Suite onboard the Suomi National Polar-orbiting Partnership satellite (VIIRS/SNPP) RRS to NIRL calibration and compared our results to previous MODIS/Aqua and Sea-viewing Wide Field-of-View Sensor onboard OrbView2 (SeaWiFS)/OrbView2 analysis. In doing so, we note that g(NIRL) sensitivities of mission-averaged RRS time series are lower for VIIRS and Sea-WiFS, relative to MODIS. At the scale of monthly climatologies (MCs), however, all sensors show prominent g(NIRL) sensitivity with that of SeaWiFS being the most substantial. These findings informed simulation analyses, whereby we identified signal-tonoise ratio (SNR) and radiant path geometry, as well as their interaction, as having notable impacts on g(NIRL) sensitivity. As such, g(NIRL) sensitivity is a necessary consideration for reflectance uncertainty budgets, especially for sensors with higher NIR SNR or particular prevailing radiant path geometries. Given the geometry components embedded within g(NIRL) sensitivity, such studies should be coupled with cross-sensor intercalibrations [e.g., using simultaneous same view (SSV) measurements] toward minimizing NIRL errors between satellite instruments, but such efforts will not completely remediate remaining cross-sensor biases in RRS. Index Terms—Moderate Resolution Imaging Spectroradiometer (MODIS)/Aqua, ocean color, ocean gyres, Sea-viewing Wide Field-of-View Sensor onboard OrbView2 (SeaWiFS), system vicarious calibration (SVC), Visible Infrared Imaging Radiometer Suite onboard the Suomi National Polar-orbiting Partnership satellite (VIIRS/SNPP).

MODIS↗

UV-Vis Spectroscopy as a Tool for Safeguards; Instrumentation installation and fundamental data collection

Two spectrophotometric process monitors, one optimized for high concentration (approximately 10 g/L) and one for trace levels (approximately 10 ppm),were developed at Argonne and installed at the SRS H-Canyon facility for field testing. These systems were built of Commercial-Off-The-Shelf components utilizing a custom, facility-specific hardware interface. The systems directly provide a qualitative measurement of process chemistry (i.e. valence state). With appropriate calibrations the systems could provide quantitative data. Laboratory tests were performed to determine the spectrophotometric molar absorptivity coefficients for relevant actinide and transition metals of interest.

36 MATERIALS SCIENCE↗

Analysis of radiant cooling system integrated with cooling tower for composite climatic conditions

Increased demand for cooling leads to consumption of a significant amount of energy by heating, ventilation, and air conditioning (HVAC) systems in buildings. Building envelope acts as a thermal barrier and plays a significant role in improving building energy efficiency. Radiant cooling systems often utilize building structure in the form of thermal storage and provide thermal comfort. The radiant cooling system has the potential of saving peak power in the buildings. In present study experimental and a simulation study is performed for chiller and cooling tower integrated chilled ceiling radiant cooling system for chilled water source and a parallel dedicated outdoor air system (DOAS) is used for providing latent load and fresh air requirements of the zone. Cooling tower based radiant cooling system is compared with a chiller-based radiant cooling system for achieving annual energy saving. Experiments are conducted for the chiller and cooling tower operated radiant cooling system. Based on experimental data, whole building simulation models of both cooling tower and chiller-based systems were calibrated. For both the simulation model of chiller and cooling tower operated radiant cooling system simulation were carried out for round the year. The annual simulation results show that the cooling tower operated radiant cooling system saves 14% energy as compared to the chilled water operated radiating cooling system.

Srivastava, Prateek↗

The Fiber Optic System for the Advanced Topographic Laser Altimeter System (ATLAS) Instrument

The Advanced Topographic Laser Altimeter System (ATLAS) Instrument has been in integration and testing over the past 18 months in preparation for the Ice, Cloud and Land Elevation Satellite - 2 (ICESat-2) Mission, scheduled to launch in 2017. ICESat-2 is the follow on to ICESat which launched in 2003 and operated until 2009. ATLAS will measure the elevation of ice sheets, glaciers and sea ice or the "cryosphere" (as well as terrain) to provide data for assessing the earth's global climate changes. Where ICESat's instrument, the Geo-Science Laser Altimeter (GLAS) used a single beam measured with a 70 m spot on the ground and a distance between spots of 170 m, ATLAS will measure a spot size of 10 m with a spacing of 70 cm using six beams to measure terrain height changes as small as 4 mm. The ATLAS pulsed transmission system consists of two lasers operating at 532 nm with transmitter optics for beam steering, a diffractive optical element that splits the signal into 6 separate beams, receivers for start pulse detection and a wavelength tracking system. The optical receiver telescope system consists of optics that focus all six beams into optical fibers that feed a filter system that transmits the signal via fiber assemblies to the detectors. Also included on the instrument is a system that calibrates the alignment of the transmitted pulses to the receiver optics for precise signal capture. The larger electro optical subsystems for transmission, calibration, and signal receive, stay aligned and transmitting sufficiently due to the optical fiber system that links them together. The robust design of the fiber optic system, consisting of a variety of multi fiber arrays and simplex assemblies with multiple fiber core sizes and types, will enable the system to maintain consistent critical alignments for the entire life of the mission. Some of the development approaches used to meet the challenging optical system requirements for ATLAS are discussed here.

global climate changes↗

Design Development of a Stable, Lightweight, Tall and Self-Deploying Lunar Tower

Deployable composite booms with spaceflight heritage are being investigated at the National Aeronautics and Space Administration (NASA) Langley Research Center (LaRC) and the Massachusetts Institute of Technology (MIT) Space Resources Workshop for their potential to be vertically deployed in the lunar gravity field, in support of the NASA Artemis campaign. This paper reports new design development results—after the original presentation at the NASA 2020 BIG Idea Challenge—for a 16.5-meter-tall, compact, self-deploying composite tower intended to support the exploration of lunar permanently shadowed regions by nearby robotic assets or humans. Possible applications include vertical solar arrays and the provision of elevated lines-of-sight to science or engineering payloads, in support of nearby targets operating in areas of interest that may be hard to reach. Useful elevated payloads include radio repeaters, remote sensing and imaging, navigation and power beaming systems. However, while these lightweight rollable booms have an excellent height to mass ratio, they typically exhibit axial curvature upon deployment resulting in appreciable lateral dead-load deflection of the tip mass relative to the tower base. This static deflection increases with tower height and tip mass, not only constraining the value delivered by the tower but also endangering its integrity. To develop a competitive, lightweight deployable composite boom tower, a capability to correct static deflections during and after deployment will be required. In this paper, a deployable guy wire stability system will be presented for the MIT / LaRC self-erecting composite boom lunar tower that provides real time measurements, maintains tension both actively (during deployment) and passively (post-deployment), and can serve as a reconfigurable platform to test and trade alternative stability system configurations, such as with added spreaders inspired by sailing boat masts. Using a calibrated photogrammetry system, the natural lateral deflection of the boom tip relative to the boom base at different deployed heights was recorded for different configurations. With real-time force measurements it was found that tensioned guy wires can significantly reduce the static tip deflection of a deployable composite boom under dead load and can dampen a dynamic oscillation in under a minute. It was also found that control authority is greatest where it is needed most, i.e., for the lever arm closest to being opposite the direction of deflection. For a tower height of at least 11 m and spreader length of at least 60 cm, a solution of differential tension in all three arms exists and, in principle, provides sufficient control authority to correct or significantly reduce boom tip deflections. Notably, natural deflections occur almost entirely normal to the seams of the boom cross-section, but the natural boom tip lateral deflection under dead load upon deployment was approximately 5% of boom deployed length, exceeding the manufacturing acceptance specification of 1%. Ongoing and future work includes the further investigation towards mitigating manufacture-caused lateral deflection, trading of alternative guy wire system designs, as well as the design development of a second-generation tower incorporating a more capable boom design with the learnings from the proof-of-concept system presented here.

deployable composite boom↗

Laser Tracker Calibration - Testing the Angle Measurement System -

Physics experiments at the SLAC National Accelerator Laboratory (SLAC) usually require high accuracy positioning, e. g. 100 {micro}m over a distance of 150 m or 25 {micro}m in a 10 x 10 x 3 meter volume. Laser tracker measurement systems have become one of the most important tools for achieving these accuracies when mapping components. The accuracy of these measurements is related to the manufacturing tolerances of various individual components, the resolutions of measurement systems, the overall precision of the assembly, and how well imperfections can be modeled. As with theodolites and total stations, one can remove the effects of most assembly and calibration errors by measuring targets in both direct and reverse positions and computing the mean to obtain the result. However, this approach does not compensate for errors originating from the encoder system. In order to improve and gain a better understanding of laser tracker angle measurement tolerances we extended our laboratory's capabilities with the addition of a horizontal angle calibration test stand. This setup is based on the use of a high precision rotary table providing an angular accuracy of better than 0.2 arcsec. Presently, our setup permits only tests of the horizontal angle measurement system. A test stand for vertical angle calibration is under construction. Distance measurements (LECOCQ & FUSS, 2000) are compared to an interferometer bench for distances of up to 32 m. Together both tests provide a better understanding of the instrument and how it should be operated. The observations also provide a reasonable estimate of covariance information of the measurements according to their actual performance for network adjustments.

43 PARTICLE ACCELERATORS↗

Instrumentation and First Results of the Reflected Solar Demonstration System for the Climate Absolute Radiance and Refractivity Observatory

The Climate Absolute Radiance and Refractivity Observatory (CLARREO) mission key goals include enabling observation of high accuracy long-term climate change trends, use of these observations to test and improve climate forecasts, and calibration of operational and research sensors. The spaceborne instrument suites include a reflected solar spectroradiometer, emitted infrared spectroradiometer, and radio occultation receivers. The requirement for the RS instrument is that derived reflectance must be traceable to Sl standards with an absolute uncertainty of <0.3% and the error budget that achieves this requirement is described in previo1L5 work. This work describes the Solar/Lunar Absolute Reflectance Imaging Spectroradiometer (SOLARIS), a calibration demonstration system for RS instrument, and presents initial calibration and characterization methods and results. SOLARIS is an Offner spectrometer with two separate focal planes each with its own entrance aperture and grating covering spectral ranges of 320-640, 600-2300 nm over a full field-of-view of 10 degrees with 0.27 milliradian sampling. Results from laboratory measurements including use of integrating spheres, transfer radiometers and spectral standards combined with field-based solar and lunar acquisitions are presented. These results will be used to assess the accuracy and repeatability of the radiometric and spectral characteristics of SOLARIS, which will be presented against the sensor-level requirements addressed in the CLARREO RS instrument error budget.

McCorkel, Joel↗

Online elemental analysis of process gases with ICP-OES: A case study on waste wood combustion

Highlights: Black-Right-Pointing-Pointer Simultaneous measurements of 23 elements in process gases of a waste wood combustor. Black-Right-Pointing-Pointer Mobile ICP spectrometer allows measurements of high quality at industrial plants. Black-Right-Pointing-Pointer Continuous online measurements with high temporal resolution. Black-Right-Pointing-Pointer Linear correlations among element concentrations in the raw flue gas were detected. Black-Right-Pointing-Pointer Novel sampling and calibration methods for ICP-OES analysis of process gases. - Abstract: A mobile sampling and measurement system for the analysis of gaseous and liquid samples in the field was developed. An inductively coupled plasma optical emission spectrometer (ICP-OES), which is built into a van, was used as detector. The analytical system was calibrated with liquid and/or gaseous standards. It was shown that identical mass flows of either gaseous or liquid standards resulted in identical ICP-OES signal intensities. In a field measurement campaign trace and minor elements in the raw flue gas of a waste wood combustor were monitored. Sampling was performed with a highly transport efficient liquid quench system, which allowed to observe temporal variations in the elemental process gas composition. After a change in feedstock an immediate change of the element concentrations in the flue gas was detected. A comparison of the average element concentrations during the combustion of the two feedstocks showed a high reproducibility for matrix elements that are expected to be present in similar concentrations. On the other hand elements that showed strong differences in their concentration in the feedstock were also represented by a higher concentration in the flue gas. Following the temporal variations of different elements revealed strong correlations between a number of elements, such as chlorine with sodium, potassium and zinc, as well as arsenic with lead, and calcium with strontium.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

TH-AB-202-11: Spatial and Rotational Quality Assurance of 6DOF Patient Tracking Systems

Purpose: External tracking systems used for patient positioning and motion monitoring during radiotherapy are now capable of detecting both translations and rotations (6DOF). In this work, we develop a novel technique to evaluate the 6DOF performance of external motion tracking systems. We apply this methodology to an infrared (IR) marker tracking system and two 3D optical surface mapping systems in a common tumor 6DOF workspace. Methods: An in-house designed and built 6DOF parallel kinematics robotic motion phantom was used to follow input trajectories with sub-millimeter and sub-degree accuracy. The 6DOF positions of the robotic system were then tracked and recorded independently by three optical camera systems. A calibration methodology which associates the motion phantom and camera coordinate frames was first employed, followed by a comprehensive 6DOF trajectory evaluation, which spanned a full range of positions and orientations in a 20×20×16 mm and 5×5×5 degree workspace. The intended input motions were compared to the calibrated 6DOF measured points. Results: The technique found the accuracy of the IR marker tracking system to have maximal root mean square error (RMSE) values of 0.25 mm translationally and 0.09 degrees rotationally, in any one axis, comparing intended 6DOF positions to positions measured by the IR camera. The 6DOF RSME discrepancy for the first 3D optical surface tracking unit yielded maximal values of 0.60 mm and 0.11 degrees over the same 6DOF volume. An earlier generation 3D optical surface tracker was observed to have worse tracking capabilities than both the IR camera unit and the newer 3D surface tracking system with maximal RMSE of 0.74 mm and 0.28 degrees within the same 6DOF evaluation space. Conclusion: The proposed technique was effective at evaluating the performance of 6DOF patient tracking systems. All systems examined exhibited tracking capabilities at the sub-millimeter and sub-degree level within a 6DOF workspace.

60 APPLIED LIFE SCIENCES↗

Demonstrating the Error Budget for the Climate Absolute Radiance and Refractivity Observatory Through Solar Irradiance Measurements

The Climate Absolute Radiance and Refractivity Observatory (CLARREO) mission addresses the need to observe highaccuracy, long-term climate change trends and to use decadal change observations as a method to determine the accuracy of climate change. A CLARREO objective is to improve the accuracy of SI-traceable, absolute calibration at infrared and reflected solar wavelengths to reach on-orbit accuracies required to allow climate change observations to survive data gaps and observe climate change at the limit of natural variability. Such an effort will also demonstrate National Institute of Standards and Technology (NIST) approaches for use in future spaceborne instruments. The current work describes the results of laboratory and field measurements with the Solar, Lunar for Absolute Reflectance Imaging Spectroradiometer (SOLARIS) which is the calibration demonstration system (CDS) for the reflected solar portion of CLARREO. SOLARIS allows testing and evaluation of calibration approaches, alternate design and/or implementation approaches and components for the CLARREO mission. SOLARIS also provides a test-bed for detector technologies, non-linearity determination and uncertainties, and application of future technology developments and suggested spacecraft instrument design modifications. Results of laboratory calibration measurements are provided to demonstrate key assumptions about instrument behavior that are needed to achieve CLARREO's climate measurement requirements. Absolute radiometric response is determined using laser-based calibration sources and applied to direct solar views for comparison with accepted solar irradiance models to demonstrate accuracy values giving confidence in the error budget for the CLARREO reflectance retrieval.

CLARREO↗

Radiation Budget Instrument On-Board Solar Calibration Target – Concept and Operation

The Radiation Budget Instrument (RBI) on-board Solar Calibration Target (SCT) concept and operation are presented in this paper. The SCT used during solar calibration of RBI is based on reflection properties of sintered Polytetrafluoroethylene (PTFE), an extremely stable, near perfect, Lambertian diffuser. The SCT incorporates three identical space grade sintered PTFE diffusers for on-orbit degradation monitoring. The SCT is used for calibration of the Shortwave (0.3 – 2.5 μm) and Total (0.3 – 100+ μm) channels of RBI. System level calibration test design and pre-flight calibration of each diffuser is also presented.

Georgiev, G.↗

Using Scattered Light From Nadir Port to Aid the Terra and Aqua MODIS Reflective Solar Band Calibration

The MODIS instruments on the Terra and Aqua spacecraft employ a solar diffuser (SD) and a solar diffuser stability monitor (SDSM) system to calibrate their reflective solar bands (RSBs), covering a spectral range from 0.4 to 2.1 µm. The UV exposure of the SD, from its sun-view port as well as the scattered light (sunlight reflected from top-of-atmosphere), has led to a wavelength dependent degradation of the SD, with larger degradation observed at shorter wavelengths. The scatter off the diffuser onto the scan mirror is in the forward direction, whereas the scatter off the diffuser onto the SDSM fold mirror is in the backward direction. Since the outgoing angles (viewed by MODIS detectors) are the same as the scheduled SD calibration, the gain derived from scattering light facilitates monitoring the dependence of the SD’s degradation on incident angles. In this paper, we present a method that uses multiple orbits over each mission to obtain a SD response to the nadir port illumination. The SD degradation estimated from the nadir port illumination is compared with the degradation derived from the sun-illuminated SD. As both Terra and Aqua spacecraft continue to drift from their nominal orbits, the SD calibration mechanism has been adapted to these drifts, especially in terms of characterizing the transmission screen function. This paper also presents the utility of this scattering light data to support the RSB calibration in the post-nominal orbit drift era of operations.

MODIS↗

Phase Calibration for the Block 1 VLBI System

Very Long Baseline Interferometry (VLBI) in the DSN provides support for spacecraft navigation, Earth orientation measurements, and synchronization of network time and frequency standards. An improved method for calibrating instrumental phase shifts has recently been implemented as a computer program in the Block 1 system. The new calibration program, called PRECAL, performs calibrations over intervals as small as 0.4 seconds and greatly reduces the amount of computer processing required to perform phase calibration.

Roth, M. G.↗

Cloud Optical Depth Measured with Ground-Based, Uncooled Infrared Imagers

Recent advances in uncooled, low-cost, long-wave infrared imagers provide excellent opportunities for remotely deployed ground-based remote sensing systems. However, the use of these imagers in demanding atmospheric sensing applications requires that careful attention be paid to characterizing and calibrating the system. We have developed and are using several versions of the ground-based "Infrared Cloud Imager (ICI)" instrument to measure spatial and temporal statistics of clouds and cloud optical depth or attenuation for both climate research and Earth-space optical communications path characterization. In this paper we summarize the ICI instruments and calibration methodology, then show ICI-derived cloud optical depths that are validated using a dual-polarization cloud lidar system for thin clouds (optical depth of approximately 4 or less).

remote sensing↗

NASA metrology information system: A NEMS subsystem

the NASA Metrology Information Systems (NMIS) is being developed as a standardized tool in managing the NASA field Center's instrument calibration programs. This system, as defined by the NASA Metrology and Calibration Workshop, will function as a subsystem of the newly developed NASA Equipment Management System (NEMS). The Metrology Information System is designed to utilize and update applicable NEMS data fields for controlled property and to function as a stand alone system for noncontrolled property. The NMIS provides automatic instrument calibration recall control, instrument historical performance data storage and analysis, calibration and repair labor and parts cost data, and instrument user and location data. Nineteen standardized reports were developed to analyze calibration system operations.

German, E. S., Jr.↗