Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “synchrotrons”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 847 records · Page 47

Multiscale X-ray phase contrast imaging of human cartilage for investigating osteoarthritis formation

The evolution of cartilage degeneration is still not fully understood, partly due to its thinness, low radio-opacity and therefore lack of adequately resolving imaging techniques. X-ray phase-contrast imaging (X-PCI) offers increased sensitivity with respect to standard radiography and CT allowing an enhanced visibility of adjoining, low density structures with an almost histological image resolution. This study examined the feasibility of X-PCI for high-resolution (sub-) micrometer analysis of different stages in tissue degeneration of human cartilage samples and compare it to histology and transmission electron microscopy. Ten 10%-formalin preserved healthy and moderately degenerated osteochondral samples, post-mortem extracted from human knee joints, were examined using four different X-PCI tomographic set-ups using synchrotron radiation the European Synchrotron Radiation Facility (France) and the Swiss Light Source (Switzerland). Volumetric datasets were acquired with voxel sizes between 0.7 × 0.7 × 0.7 and 0.1 × 0.1 × 0.1 µm 3 . Data were reconstructed by a filtered back-projection algorithm, post-processed by ImageJ, the WEKA machine learning pixel classification tool and VGStudio max. For correlation, osteochondral samples were processed for histology and transmission electron microscopy. X-PCI provides a three-dimensional visualization of healthy and moderately degenerated cartilage samples down to a (sub-)cellular level with good correlation to histologic and transmission electron microscopy images. X-PCI is able to resolve the three layers and the architectural organization of cartilage including changes in chondrocyte cell morphology, chondrocyte subgroup distribution and (re-)organization as well as its subtle matrix structures. X-PCI captures comprehensive cartilage tissue transformation in its environment and might serve as a tissue-preserving, staining-free and volumetric virtual histology tool for examining and chronicling cartilage behavior in basic research/laboratory experiments of cartilage disease evolution.

3D analysis↗

Data processing methods and data acquisition for samples larger than the field of view in parallel-beam tomography

Parallel-beam tomography systems at synchrotron facilities have limited field of view (FOV) determined by the available beam size and detector system coverage. Scanning the full size of samples bigger than the FOV requires various data acquisition schemes such as grid scan, 360-degree scan with offset center-of-rotation (COR), helical scan, or combinations of these schemes. Though straightforward to implement, these scanning techniques have not often been used due to the lack of software and methods to process such types of data in an easy and automated fashion. The ease of use and automation is critical at synchrotron facilities where using visual inspection in data processing steps such as image stitching, COR determination, or helical data conversion is impractical due to the large size of datasets. Here, we provide methods and their implementations in a Python package, named Algotom, for not only processing such data types but also with the highest quality possible. The efficiency and ease of use of these tools can help to extend applications of parallel-beam tomography systems.

36 MATERIALS SCIENCE↗

Refractive axicon for X-ray microscopy applications: design, optimization, and experiment

In a full-field transmission X-ray microscopy (TXM) setup, a condenser X-ray optical element is used to illuminate the sample by condensing the X-ray beam delivered by the synchrotron storage ring. On-going and future upgrades of synchrotron facilities to diffraction-limited storage rings will pose new challenges to these TXM setups, such as much smaller X-ray beams on the condenser. Here, we demonstrate that a refractive axicon can be used as an X-ray beam shaper to match the ring-shaped aperture of the condenser. Aiming at more efficient use of the incoming X-ray intensity, we explore several axicon designs both analytically and with numerical simulations. The axicons were produced by two-photon polymerization 3D printing on thin silicon nitride membrane substrates. The first characterization of the axicon was carried out at the TOMCAT beamline of the Swiss Light Source (Switzerland).

47 OTHER INSTRUMENTATION↗

AutoFocus: AI/ML-driven real-time wavefront diagnostics to autonomously align and optimize X-ray optics

We present an integrated system that combines advanced wavefront diagnostics with artificial intelligence (AI) to automate and optimize X-ray optics at synchrotron beamlines. This system couples real-time wavefront sensing with AI-driven control algorithms to achieve precise beam alignment, stabilization, and performance optimization. A key feature is the use of multi-fidelity transfer learning, which enables knowledge gained from both real-world beamline optimizations and ultra-realistic digital twin simulations to be effectively applied to in situ optimization. By leveraging multi-objective bayesian optimization, the system continuously refines its performance, reducing optimization time and minimizing the need for manual adjustments. Designed for seamless deployment, it operates with existing beamline hardware and provides an intuitive graphical interface. Initial deployments at the advanced photon source beamlines have demonstrated its ability to enhance beam stability, improve reproducibility, and significantly streamline alignment procedures. This AI-enhanced control framework represents a significant step toward fully autonomous beamline operation in next-generation synchrotron facilities.

Rebuffi, Luca [Argonne National Laboratory (ANL), ↗

Incident excitation effects on ZnO-based photoluminescence

Zinc oxide (ZnO) is an attractive semiconductor material owing to a wide band gap, large exciton binding energy, and strong luminescent properties. Two distinct spectral regions are present in the room temperature emission of this material: a narrow line in the UV/near-UV region that is excitonic in nature and a lower energy broad emission band centered in the green/yellow region. Commercially available ZnO particles containing excess Zn and oxygen vacancy defect sites (referred to as ZnO:Zn) were excited using three light sources to study different radiative recombination regimes of the as-received powders. First, a UV LED at a center wavelength of 365 nm provided low irradiance (0.02–0.08 W/cm 2 ) with varying pulse widths (continuous operation to 16 ns). Second, the third harmonic of a pulsed Nd:YAG laser provided high irradiances (∼10 4 –10 6 W/cm 2 ) at a fixed nominal pulse width of 5 ns. Finally, a continuous polychromatic synchrotron X-ray source was also used to excite the ZnO:Zn powders. During UV LED excitation, a low number of carriers are created in the material, leading to an anticipated linear relationship between luminescence and irradiance. This held true for defect luminescence; however, there was an observed enhancement of exciton emission relative to the UV LED intensity as the pulse width was decreased, independent of irradiance. During UV laser excitation, the number of carriers was significantly increased, raising the material into a bimolecular recombination regime, which produced exciton emission much stronger than visible band emission. Finally, spectra obtained during synchrotron X-ray excitation, whose continuous illumination and higher penetration depth yielded higher emission from defect sites relative to exciton emission. A redshift in the exciton emission was also observed as excitation pulse width and sample temperature were varied, and is discussed.

Westphal, Eric Robert [Sandia National Lab. (SNL-N↗

Disentangling x-ray dichroism and birefringence via high-purity polarimetry

High-brilliance synchrotron radiation sources have opened new avenues for x-ray polarization analysis that go far beyond conventional polarimetry in the optical domain. With linear x-ray polarizers in a crossed setting, polarization extinction ratios down to 10 -10 can be achieved. This renders the method sensitive to probe the tiniest optical anisotropies that would occur, for example, in strong-field quantum electrodynamics due to vacuum birefringence and dichroism. Here we show that high-purity polarimetry can be employed to reveal electronic anisotropies in condensed matter systems with utmost sensitivity and spectral resolution. Taking CuO and La 2 CuO 4 as benchmark systems, we present a full characterization of the polarization changes across the Cu K-absorption edge and their separation into dichroic and birefringent contributions. At diffraction-limited synchrotron radiation sources and x-ray lasers, where polarization extinction ratios of 10 -12 can be achieved, our method has the potential to assess birefringence and dichroism of the quantum vacuum in extreme electromagnetic fields.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

X-Ray Diffraction and Electron Microscopy Studies of the Size Effects on Pressure-Induced Phase Transitions in CdS Nanocrystals

In recent years, investigations of the phase transition behavior of semiconducting nanoparticles under high pressure has attracted increasing attention due to their potential applications in sensors, electronics, and optics. However, current understanding of how the size of nanoparticles influences this pressure-dependent property is somewhat lacking. In particular, phase behaviors of semiconducting CdS nanoparticles under high pressure have not been extensively reported. Therefore, in this work, CdS nanoparticles of different sizes are used as a model system to investigate particle size effects on high-pressure-induced phase transition behaviors. In particular, 7.5, 10.6, and 39.7 nm spherical CdS nanoparticles are synthesized and subjected to controlled high pressures up to 15 GPa in a diamond anvil cell. Analysis of all three nanoparticles using in-situ synchrotron wide-angle X-ray scattering (WAXS) data shows that phase transitions from wurtzite to rocksalt occur at higher pressures than for bulk material. Bulk modulus calculations not only show that the wurtzite CdS nanomaterial is more compressible than rocksalt, but also that the compressibility of CdS nanoparticles depends on their particle size. Furthermore, sintering of spherical nanoparticles into nanorods was observed for the 7.5 nm CdS nanoparticles. Our results provide new insights into the fundamental properties of nanoparticles under high pressure that will inform designs of new nanomaterial structures for emerging applications.

Meng, Lingyao↗

Accelerated microwave-assisted synthesis and in situ X-ray scattering of tungsten-substituted vanadium dioxide (V 1-x W x O 2 )

Vanadium dioxide (VO 2 ) has been widely studied due to its metal-insulator phase transition at 68°C, below which it is a semiconducting monoclinic phase, P2 1 /c, and above it is a metallic tetragonal phase, P4 2 /mnm. Substituting vanadium with transition metals allows transition temperature tunability. An accelerated microwave-assisted synthesis for VO 2 and 5d tungsten substituted VO 2 presented herein decreased synthesis time by three orders of magnitude while maintaining phase purity, particle size, and transition character. Tungsten substitution amount was determined using inductively coupled plasma-optical emission spectroscopy. Differential scanning calorimetry, superconducting quantum interference device measurements, and in-situ heating and cooling experiments monitored through synchrotron x-ray diffraction (XRD) confirmed the transition temperature decreased with increased tungsten substitution. Scanning electron microscopy analyzed through the line-intercept method produced an average particle size of 3 – 5 μm. Average structure and local structure phase purity was determined through Rietveld analysis of synchrotron XRD and least-squares refinement of pair-distribution function data.

36 MATERIALS SCIENCE↗

Transverse Beam Emittance Measurement by Undulator Radiation Power Noise

Generally, turn-to-turn power fluctuations of incoherent spontaneous synchrotron radiation in a storage ring depend on the 6D phase-space distribution of the electron bunch. In some cases, if only one parameter of the distribution is unknown, this parameter can be determined from the measured magnitude of these power fluctuations. In this contribution, we report the results of our experiment at the Integrable Optics Test Accelerator (IOTA) storage ring, where we carried out an absolute measurement (no free parameters or calibration) of a small vertical emittance (5–15 nm rms) of a flat beam by this new method, under conditions, when the small vertical emittance is unresolvable by a conventional synchrotron light beam size monitor.

43 PARTICLE ACCELERATORS↗

Observation of Undulator Radiation Generated by a Single Electron Circulating in a Storage Ring and Possible Applications

An experimental study into the undulator radiation, generated by a single electron was carried out at the Integrable Optics Test Accelerator (IOTA) storage ring at Fermilab. The individual photons were detected by a Single Photon Avalanche Diode (SPAD) at an average rate of 1 detection per 300 revolutions in the ring. The detection events were continuously recorded by a picosecond event timer for as long as 1 minute at a time. The collected data were used to test if there is any deviation from the classically predicted Poissonian photostatistics. It was motivated by the observation * of sub-Poissonian statistics in a similar experiment. The observation * could be an instrumentation effect related to low detection efficiency and long detector dead time. In our experiment, the detector (SPAD) has a much higher efficiency (65%) and a much lower dead time. In addition, we show that the collected data (recorded detection times) can be used to study the synchrotron motion of a single electron and infer some parameters of the ring. For example, by comparing the results of simulation and measurement for the synchrotron motion we were able to estimate the magnitude of the RF phase jitter.

43 PARTICLE ACCELERATORS↗

Further Measurements of Beam-Beam Interactions in a Gear-Changing System in DESIREE

In this work we detail experiments performed on a gear-changing system using the Double ElectroStatic Ion Ring ExpEriment (DESIREE). A gear-changing system is one where there are different harmonic numbers in each ring. This experiment used carbon and nitrogen beams in a 4 on 3 gear-changing arrangement, with the last bunch of each left off. The bunch length can be measured and synchrotron motion detected. We performed this measurement on three different values of carbon current, and present the differences in the bunch length frequency spectrum here, which correspond to twice the synchrotron frequencies.

Nissen, E. A.↗

Modeling of standing wave RF cavities for tracking through multi-pass energy recovery linac

Short bunches, high current and multiple linac pass are all characteristics of Energy Recovery Linacs (ERLs), which may result in collective effects. They in turn, may affect the beam, degrading its quality, or even yield to instabilities causing a beam loss. To study and mitigate these effects one needs a numerical simulation code, that can take into account both the collective effects, as well as, particular ERL features, such as a multi-turn design that does not reach a steady state or the multiple passages of the beam through Radio-Frequency (RF) cavities at different energies. CODAL [1], a code developed by SOLEIL in collaboration with IJCLab, enables such studies. It is a 6 dimensional (6D) tracking code applying 'kicks' based on the integration of the local Hamiltonian for each element of the lattice. It is also capable of simulating space charge, wakefields and coherent synchrotron radiation. However, to correctly take into account the ERL dynamics, an upgrade had to be made to include the effect of a standing wave RF cavity in 6D. In this paper, we will concentrate on the implementation and benchmarking (with DESY’s tracking code ASTRA [2]) of both the longitudinal and the transverse models (by J.B. Rosenzweig and L. Serafini [3]), which we use to carry out tracking of fully analytical 6D RF cavity.

Bogacz, A.↗

Experimental 4D Tracking of a Single Electron in IOTA

We present the results of the first experiments on 4-dimensional phase-space tracking of a single electron in a storage ring, using a linear multi-anode photomultiplier tube for simultaneously measuring transverse coordinates and arrival times of synchrotron-radiation pulses. During the next few months, full 6D tracking will be implemented. This technology makes it possible to characterize the motion of a single particle, i.e. simultaneously tracking of amplitudes and phases for slow synchrotron oscillations and fast betatron oscillations. Complete tracking of a single particle enables the first direct measurements of dynamical properties, including invariants, amplitude-dependent tunes, and chaotic behavior.

43 PARTICLE ACCELERATORS↗

Status of 22 GeV CEBAF Upgrade Using FFA Arcs

Jefferson Lab is exploring an upgrade to extend CEBAF’s energy to ~22 GeV within the existing tunnel by incorporating Fixed-Field Alternating-Gradient (FFA) arcs. In this scheme, the two lowest-energy electromagnetic arcs are removed, the remaining arcs are reassigned to lower energies, and a new pair of high-energy FFA arcs enables six additional recirculations using the existing SRF linacs. The non-scaling FFA lattice employs Halbach-derived permanent magnets with provisions for dipole, quadrupole, and higher-order components, offering large momentum acceptance and reduced operating cost. Implementing this concept requires updated linac optics, modifications to the remaining arcs, and a redesigned electromagnetic switchyard. Ongoing beam-dynamics studies address synchrotron-radiation–induced energy loss and emittance growth, along with strategies for their mitigation.

Ogur, S. [Thomas Jefferson National Accelerator Fa↗

Experimental Phase-Space Tracking of a Single Electron in a Storage Ring

This paper presents the results of the first ever experimental tracking of the betatron and synchrotron phases for a single electron in the Fermilab’s IOTA ring. The reported technology makes it is possible to fully track a single electron in a storage ring, which requires tracking of amplitudes and phases for both, slow synchrotron and fast betatron oscillations.

43 PARTICLE ACCELERATORS↗

Galaxy Clusters Discovered via the Thermal Sunyaev-Zel’dovich Effect in the 500-square-degree SPTpol Survey

We present a catalog of 689 galaxy cluster candidates detected at significance ξ > 4 via their thermal Sunyaev-Zel’dovich (SZ) effect signature in 95 and 150 GHz data from the 500-square-degree SPTpol survey. We use optical and infrared data from the Dark Energy Camera and the Wide-field Infrared Survey Explorer (WISE) and Spitzer satellites, to confirm 544 of these candidates as clusters with ~ 94% purity. The sample has an approximately redshift-independent mass threshold at redshift z > 0.25. The confirmed sample spans 1.5 × 10 14 < M 500 c < 9 × 10 14 M ⊙ /h 70 and 0.03 < z ≲ 1.6 in mass and redshift, respectively, with a median mass of 2.5×10 14 M ⊙ /h 70 and median redshift z = 0.7; 21% of the confirmed clusters are at z > 1. We use external radio data from the Sydney University Molonglo Sky Survey (SUMSS) to estimate contamination to the SZ signal from synchrotron sources. The contamination reduces the recovered ξ by a median value of 0.032, or ~ 0.8% of the ξ = 4 threshold value, and ~ 7% of candidates have a predicted contamination greater than Δξ = 1. With the exception of a small number of systems (< 1%), an analysis of clusters detected in single-frequency 95 and 150 GHz data shows no significant contamination of the SZ signal by emission from dusty or synchrotron sources. This cluster sample, representing the deepest SZ-selected cluster sample to date, will be a key component in upcoming astrophysical and cosmological analyses of clusters. In addition to the cluster catalog, we also release the millimeter-wave maps and associated data products used to produce this sample. These maps have depths of 5.3 (11.7) µK CMB -arcmin at 150 (95) GHz and an effective angular resolution of 1. '2 (1. '7). The SPTpol products are available at https:// pole.uchicago.edu/public/data/sptpol_500d_clusters/index.html, and the NASA LAMBDA website. An interactive sky server with the SPTpol maps and Dark Energy Survey data release 2 images is also available at NCSA https://skyviewer.ncsa.illinois.edu.

79 ASTRONOMY AND ASTROPHYSICS↗

Compact, Achromatic Non-scaling FFAG Accelerator for HEP, Commercial and Medical Applications (CRADA FRA-2008-0005 Final Report)

Proton and light-ion accelerators have many research and medical applications, but the current state of technology in accelerators severely limits their widespread use: (1) synchrotrons have an intrinsic low duty cycle and become quite large for light ions; and (2) cyclotrons do not have energy variability and require complex superconducting magnets for high energy. A new concept in non-scaling Fixed-Field Alternating-Gradient (FFAGs) has been invented that incorporates both the energy variability of the synchrotron and the high duty cycle of the cyclotron. The concept uses normal-conducting, combined-function magnets that apply only constant (dipole) and linear-gradient (quadrupole) fields to stabilize the accelerator. This project will develop an optimized design for a new non-scaling and cost-effective innovation in FFAG accelerators. The accelerator design will have optics that can stably accelerate protons to 250 MeV (or higher) and carbon ions to =200 MeV, an energy considered ideal for radiation therapy. Phase I will optimize, fully simulate, and demonstrate the feasibility of this accelerator. Commercial Applications and other Benefits as described by the awardee: The fixed-field acceleration concept should eliminate some of the most pronounced technical difficulties, expense, maintenance, and required expertise faced in conventional proton and light-ion accelerators. In addition to the application for high energy physics, these accelerators should have application in cancer treatment, radiopharmaceuticals, and medical isotope production, and materials science.

43 PARTICLE ACCELERATORS↗