Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “spectral methods”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 847 records · Page 47

Images and Spectral Performance of WFC3 Interference Filters

The Wide Field Camera 3 (WFC3) is a panchromatic imager that will be deployed in the Hubble Space Telescope (HST). The mission of the WFC3 is to enhance HST1s imaging capability in the ultraviolet, visible and near-infrared spectral regions. Together with a wavelength coverage spanning 2000A to 1.7 micron, the WFC3 high sensitivity, high spatial resolution, and large field-of-view provide the astronomer with an unprecedented set of tools for exploring all types of exciting astrophysical terrain and for addressing many key questions in astronomy today. The filter compliment, which includes broad, medium, and narrow band filters, naturally reflects the diversity of astronomical programs to be targeted with WFC3. The WFC3 holds 61 UVIS filters elements, 14 IR filters, and 3 dispersive elements. During ground testing, the majority of the UVIS filters were found to exhibit excellent performance consistent with or exceeding expectations; however, a subset of filters showed considerable ghost images; some with relative intensity as high as 10-15%. Replacement filters with band-defining coatings that substantially reduce these ghost images were designed and procured. A state-of-the-art characterization setup was developed to measured the intensity of ghost images, focal shift, wedge direction , transmitted uniformity and surface feature of filters that could effect uniform flat field images. We will report on this new filter characterization methods, as well as the spectral performance measurements of the in-band transmittance and blocking.

Quijada, Manuel A.↗

A new spectral synthesis procedure for multivariable regulators

A method for selecting a multivariable state feedback controller that simultaneously achieves an a priori specification on closed loop eigenvalues and good mode mixing is presented. The problem is solved by projecting a desired modal matrix onto a constraint set containing the null space of the closed-loop state matrix, while assuring that the projection is in the null space. The feedback matrix follows immediately in the formulation. An example involving a helicopter hover controller is presented.

Maynard, R. A.↗

Effect of spectral shape on acoustic fatigue life estimates

Methods for estimating fatigue life due to random loading are briefly reviewed. These methods include a probabilistic approach in which the expected value of the rate of damage accumulation is computed by integrating over the probability density of damaging events and a method which consists of analyzing the response time history to count damaging events. It is noted that it is necessary to employ a time domain approach to perform Rainflow counting, while simple peak counting may be accomplished using the probabilistic method. Data obtained indicate that Rainflow counting produces significantly different fatigue life predictions than other methods that are commonly used in acoustic fatigue predictions. When low-frequency oscillations are present in a signal along with high-frequency components, peak counting will produce substantially shorter fatigue lives than Rainflow counting. It is concluded that Rainflow counting is capable of providing reliable fatigue life predictions for acoustic fatigue studies.

Miles, R. N.↗

Spectral interpolation - Zero fill or convolution

Zero fill, or augmentation by zeros, is a method used in conjunction with fast Fourier transforms to obtain spectral spacing at intervals closer than obtainable from the original input data set. In the present paper, an interpolation technique (interpolation by repetitive convolution) is proposed which yields values accurate enough for plotting purposes and which lie within the limits of calibration accuracies. The technique is shown to operate faster than zero fill, since fewer operations are required. The major advantages of interpolation by repetitive convolution are that efficient use of memory is possible (thus avoiding the difficulties encountered in decimation in time FFTs) and that is is easy to implement.

Forman, M. L.↗

Hyperspectral Remote Sensing and Ecological Modeling Research and Education at Mid America Remote Sensing Center (MARC): Field and Laboratory Enhancement

The purpose of this project was to establish a new hyperspectral remote sensing laboratory at the Mid-America Remote sensing Center (MARC), dedicated to in situ and laboratory measurements of environmental samples and to the manipulation, analysis, and storage of remotely sensed data for environmental monitoring and research in ecological modeling using hyperspectral remote sensing at MARC, one of three research facilities of the Center of Reservoir Research at Murray State University (MSU), a Kentucky Commonwealth Center of Excellence. The equipment purchased, a FieldSpec FR portable spectroradiometer and peripherals, and ENVI hyperspectral data processing software, allowed MARC to provide hands-on experience, education, and training for the students of the Department of Geosciences in quantitative remote sensing using hyperspectral data, Geographic Information System (GIS), digital image processing (DIP), computer, geological and geophysical mapping; to provide field support to the researchers and students collecting in situ and laboratory measurements of environmental data; to create a spectral library of the cover types and to establish a World Wide Web server to provide the spectral library to other academic, state and Federal institutions. Much of the research will soon be published in scientific journals. A World Wide Web page has been created at the web site of MARC. Results of this project are grouped in two categories, education and research accomplishments. The Principal Investigator (PI) modified remote sensing and DIP courses to introduce students to ii situ field spectra and laboratory remote sensing studies for environmental monitoring in the region by using the new equipment in the courses. The PI collected in situ measurements using the spectroradiometer for the ER-2 mission to Puerto Rico project for the Moderate Resolution Imaging Spectrometer (MODIS) Airborne Simulator (MAS). Currently MARC is mapping water quality in Kentucky Lake and vegetation in the Land-Between-the Lakes (LBL) using Landsat-TM data. A Landsat-TM scene of the same day was obtained to relate ground measurements to the satellite data. A spectral library has been created for overstory species in LBL. Some of the methods, such as NPDF and IDFD techniques for spectral unmixing and reduction of effects of shadows in classifications- comparison of hyperspectral classification techniques, and spectral nonlinear and linear unmixing techniques, are being tested using the laboratory.

Cetin, Haluk↗

Influence of the atmosphere on spectral radiance and contrasts of natural formations measured from space

The method of transfer functions is discussed that enable the elimination of atmospheric effects from spectral photometric data measured from spacecraft. Soyuz 7, 9 and Salyut spacecraft data were used. The results made it possible to estimate the variations in the transfer functions in the visible spectral region depending on the albedo of the underlying surface both for the uniform surfaces and near the boundary between two uniform underlying surfaces.

Kondratyev, K. Y.↗

Worldwide variations in atmospheric transmission. I - Baseline results from Smithsonian observations.

The spectrobolometer used in the studies is discussed, giving attention to instrument design, the method of recording, and the spectral resolution. The atmospheric transmission for each wavelength was determined by making observations over a range of air masses. The precipitable water vapor values were found from the spectrobolograms by measurement of the depths of water vapor bands at 0.935, 1.13, and 1.47 microns. The results of the studies are discussed together with seasonal variations, long term trends, and the nature of the aerosols.

Roosen, R. G.↗

Iodine imaging using spectral analysis

Existing radiographic imaging systems provide images which represent an integration or averaging over the energy spectrum. In order to provide noninvasive angiography it is necessary to image the relatively small amounts of iodine which are available following an intravenous administration. This is accomplished by making use of the special spectral characteristics of iodine. Two methods will be presented. One involves a special grating for encoding the iodine information in the form of a fine line pattern. This is subsequently decoded to provide images of iodinated structures which are otherwise almost invisible. The second method utilizes a scanned X-ray beam which is rapidly switched in the high energy region. In this region, iodine experiences significant variations in the attenuation coefficient while bone and soft tissue do not. An efficient and accurate X-ray detector can be used with scanned X-ray beams. This provides a high degree of sensitivity enabling the visualization of small vessels containing relatively dilute iodine.

Macovski, A.↗

The estimation of decay coefficient in pulsed transient data

The problem of estimation and interpretation of a decay coefficient in a pulsed transient signal is considered. Two methods are proposed in estimating the decay coefficient of pulsed decay transient data. The methods are derived through a spectral analysis for a parametric model of impulse response function of signal frequency. The several pulsed response data from T burner tests as well as some synthesized data are analyzed and the performance of the estimation procedures are examined. Suggestions for further research in this area are offered. The estimation procedures presented can be extended to the case of multiple frequencies in pulse response function and time dependent decay or growth coefficients.

Park, T. W.↗

LANDSAT-4 multispectral scanner (MSS) subsystem radiometric characterization

The multispectral band scanner (mass) and its spectral characteristics are described and methods are given for relating video digital levels on computer compatible tapes to radiance into the sensor. Topics covered include prelaunch calibration procedures and postlaunch radiometric processng. Examples of current data resident on the MSS image processing system are included. The MSS on LANDSAT 4 is compared with the scanners on earlier LANDSAT satellites.

Alford, W.↗

Hot DA white dwarfs seen with Einstein, an ultrahot H- and He-poor white dwarf, and Zanstra temperatures of planetary nebula nuclei

Einstein observations of hot DA white dwarfs are analyzed using model atmospheres. It is found that, for a relatively limited sample of stars, that hot He-poor stars like HZ 43 are indeed the exception, and that there is an apparent correlation between He/H ratio and increasing temperature. The seventh brightest soft X-ray source in the HEAO-A1 catalog, H1504+65, turns out to be an ultrahot white dwarf star, with a temperature of approximately 160,000 K, showing spectral features of the Zanstra method for determining the temperatures of central stars of planetary nebulae demonstrates that the H I Zanstra temperatures are indeed reliable and suggests that a substantial fraction of these central stars have He/H ratios which are considerably less than the solar value.

Shipman, Harry L.↗

Model reductions using a projection formulation

A new methodology for model reduction of MIMO systems exploits the notion of an oblique projection. A reduced model is uniquely defined by a projector whose range space and orthogonal to the null space are chosen among the ranges of generalized controllability and observability matrices. The reduced order models match various combinations (chosen by the designer) of four types of parameters of the full order system associated with (1) low frequency response, (2) high frequency response, (3) low frequency power spectral density, and (4) high frequency power spectral density. Thus, the proposed method is a computationally simple substitute for many existing methods, has an extreme flexibility to embrace combinations of existing methods and offers some new features.

De Villemagne, Christian↗

Improved evaluation of optical depth components from Langley plot data

A simple, iterative procedure to determine the optical depth components of the extinction optical depth measured by a solar radiometer is presented. Simulated data show that the iterative procedure improves the determination of the exponent of a Junge law particle size distribution. The determination of the optical depth due to aerosol scattering is improved as compared to a method which uses only two points from the extinction data. The iterative method was used to determine spectral optical depth components for June 11-13, 1988 during the MAC III experiment.

Biggar, S. F.↗

Multiwavelength pyrometry for nongray surfaces in the presence of interfering radiation

A NASA developed multiwavelength pyrometry technique for nongray surfaces was extended to also measure surface temperature in the presence of interfering radiation. This radiation is produced by heat lamps used to raise the temperature of the surface. The necessary instruments are a spectral radiometer, an auxiliary radiation source, and a computer. Four radiation spectra are recorded: (1) the unobstructed spectrum characterizing an auxiliary radiation source; (2) the unobstructed spectrum characterizing the interfering radiation; (3) the radiation spectrum consisting of surface emission plus the interfering radiation; and (4) a spectrum consisting of the radiations of (3) plus the reflected radiation due to the incidence of the auxiliary radiation source on this surface. With these spectra, application of two variable, nonlinear, least squares, curve fitting computer software determines the surface temperature and the spectral emissivity. Use of the method to measure the surface temperature of silicon carbide under a simulated interference condition is shown at a low temperature just above ambient. The instrumentation necessary to extend the method to elevated temperatures is discussed.

Ng, Daniel↗

Viscous and inviscid instabilities of a trailing vortex

The linear stability of the trailing line vortex model of Batchelor (1964) is studied using a spectral collocation and matrix eigenvalue method. The entire unstable region in the swirl/axial wavenumber parameter space is mapped out for various azimuthal wavenumbers for both the inviscid and viscous stability problem. The results of the study provide a direct numerical validation of the large-azimuthal-wavenumber asymptotic analysis of Leibovich and Stewartson (1983). It is shown that accurate results are obtained up to azimuthal wavenumbers of 10,000 and greater, and the agreement with the asymptotic theory is excellent.

Mayer, Ernst W.↗

Broad-band linear polarization in cool stars. II - Amplitude and wavelength dependence for magnetic and scattering regions

We have developed a model to estimate the amplitude and wavelength dependence of broad-band linear polarization (BLP) from magnetic regions on cool stars. The model includes corrections both for line blends and for the partial cancellation of polarization in the vector sum over the stellar disk. Our results agree with recent calculations of BLP in the red, but show larger amplitudes and a different wavelength dependence in the blue. We find that the detailed wavelength dependence of the polarization is complex and varies with effective temperature and gravity due to changes in line blanketing. The BLP amplitudes depend strongly on field strength, blanketing, and magnetic region filling factor and geometry. We make rough estimates of the maximum BLP for stars of various spectral types and demonstrate a method for deriving a lower limit to the filling factor from the maximum observed BLP. This lower limit is related to the fractional area covered by the spatially asymmetric component of magnetic regions.

Saar, Steven H.↗