At least 847 records · Page 47

Two X-ray-selected BL Lacertae objects observed with the HEAO 1 scanning modulation collimator

Two 16th magnitude BL Lac objects, H1101 - 232 and H1426 + 428, have been discovered. Each is a persistent and relatively bright X-ray source. A 2.7 percent linear polarization is measured in the optical emission or H101 - 232. The X-ray identification of H1426 + 428 is confirmed in an Exosat observation. The X-ray spectrum is well-modeled by a power law with an energy index of 1.19. Both BL Lac objects exhibit high f(x)/f(opt) ratios and they show a distinct resemblance to other X-ray selected BL Lac objects. The host galaxies are about 18th mag with angular diameters of about 20 arcsec and each may be the dominant member of a cluster of galaxies. Additional wide-slit spectroscopy reveals faint absorption features with redshifts of 0.129 for H1426 + 428 and 0.186 for H1101 - 232. The implied X-ray and optical luminosities exceed 10 to the 45th ergs/s for both BL Lac nuclei, assuming isotropic emission.

Remillard, R. A.↗

In situ CF3 Detection in Low Pressure Inductive Discharges by Fourier Transform Infrared Spectroscopy

The detection of CF(x) (x=1-3) radicals in low pressure discharges using source gases such as CF4 and CHF3 is of importance to the understanding of their chemical structure and relevance in plasma based etching processes. These radicals are known to contribute to the formation of fluorocarbon polymer films, which affect the selectivity and anisotropy of etching. In this study, we present preliminary results of the quantitative measurement of trifluoromethyl radicals, CF3, in low pressure discharges. The discharge studied here is an inductively (transformer) coupled plasma (ICP) source in the GEC reference cell, operating on pure CF4 at pressures ranging from 10 - 100 mTorr, This plasma source generates higher electron number densities at lower operating pressures than obtainable with the parallel-plate capacitively coupled version of the GEC reference cell. Also, this expanded operating regime is more relevant to new generations of industrial plasma reactors being used by the microelectronics industry. Fourier transform infrared (FTIR) spectroscopy is employed to observe the absorption band of CF3 radicals in the electronic ground state X2Al in the region of 1233-1270/cm. The spectrometer is equipped with a high sensitivity HgCdTe (MCT) detector and has a fixed resolution of 0.125/cm. The CF3 concentrations are measured for a range of operating pressures and discharge power levels.

Kim, J. S.↗

Pulling Results Out of Thin Air: Four Years of Ozone and Greenhouse Gas Measurements by the Alpha Jet Atmospheric Experiment (AJAX)

The Alpha Jet Atmospheric eXperiment (AJAX) has been measuring atmospheric ozone, carbon dioxide, methane and meteorological parameters from near the surface to 8000 m since January 2011. The main goals are to study photochemical ozone production and the impacts of extreme events on western US air quality, provide data to support satellite observations and aid in the quantification of emission sources e.g. wildfires, urban outflow, diary and oil and gas. The aircraft is based at Moffett Field and flies multiple times a month to sample vertical profiles at selected sites in California and Nevada, providing long-term data records at these sites. AJAX is also uniquely positioned to launch with short notice sampling flights in rapid response to extreme events e.g. the 2013 Yosemite Rim fire. This talk will focus on the impacts of vertical transport on surface air quality, and investigation of emission sources from diaries and wildfires.

AJAX↗

The Kepler Full Frame Images

NASA's exoplanet discovery mission Kepler provides uninterrupted 1-min and 30-min optical photometry of a 100 square degree field over a 3.5 yr nominal mission. Downlink bandwidth is filled at these short cadences by selecting only detector pixels specific to 105 preselected stellar targets. The majority of the Kepler field, comprising 4 x 10(exp 6) m_v < 20 sources, is sampled at much lower 1-month cadence in the form of a full-frame image. The Full Frame Images (FFIs) are calibrated by the Science Operations Center at NASA Ames Research Center. The Kepler Team employ these images for astrometric and photometric reference but make the images available to the astrophysics community through the Multimission Archive at STScI (MAST). The full-frame images provide a resource for potential Kepler Guest Observers to select targets and plan observing proposals, while also providing a freely-available long-cadence legacy of photometric variation across a swathe of the Galactic disk.

Dotson, Jessie L.↗

Contributions of low-luminosity sources to the X-ray background

We have exploited the HEAO 1 A-2 data base to determine hard X-ray fluxes, or upper limits, for complete optically selected samples of active and normal galaxies, in order to estimate or to constrain their local X-ray luminosity functions. We find that the luminosity function of Seyfert nuclei must flatten down drastically shortly below the observational limit of Piccinotti et al.; little can be added by dwarf active nuclei hidden in otherwise normal galaxies. We also analyze the possible contribution to the X-ray background from galaxies with strong star formation activity, in the light of the possibility of a substantial cosmological evolution suggested by recent radio and IRAS data.

Nuclei galaxies↗

On the surface density of X-ray selected BL Lacertae objects

Only a handful of BL Lac objects have been found as a result of systematic optical identification of serendipitous Einstein X-ray sources. By combining the data from two flux-limited complete X-ray surveys (the HEAO 1 A-2 and the Einstein Observatory Medium Sensitivity Survey) the surface density of X-ray emitting BL Lac objects is evaluated as a function of their X-ray flux. It is found that a single power law is not an acceptable representation of the BL Lac objects' X-ray log N-log S. The number-flux relationship is consistent with the Euclidean slope at 'high' flux levels but shows a drastic flattnring below fluxes of the order of 10 to the -12th ergs per sq cm/s. The implications of this result are briefly discussed with respect to the luminosity function, the cosmological evolution, and the X-ray to optical flux ratio in BL Lac objects.

Maccacaro, T.↗

The Control of Float Zone Interfaces by the Use of Selected Boundary Conditions

Since the float zone process involves two solid-melt interfaces, possible gas interfaces, heat and mass transfers, various driving forces and complex heating sources, an analysis of the entire process would be very complex. For an initial investigation, a more feasible approach is to examine each component of the process separately. The three principal components are: (1) the shapes of the melt and solid-melt interfaces, (2) the heat and mass transfers, and (3) the heating and cooling sources. This study combined facets of all three components. The purpose of this effort was to study and compute the surface boundary conditions required to give flat (float zone) FZ solid-melt interfaces. This study was undertaken in two phases. The first phase was to investigate the solid zones surface boundary conditions required for flat solid-melt interfaces when given the melt zone surface boundary conditions. The second phase complemented the first and was to investigate the melt zone surface boundary conditions required for flat solid-melt interfaces if given the solid zones surface boundary conditions. Dual integral transform methods were used in both phases; in addition, the use of various numerical methods for differential equations and linear systems of equations were required.

Foster, L. M.↗

Multispectral linear array multiband selection device

An apparatus for detecting multiple spectral bands, individually or concurrently, using linear detector arrays is described. The system employs a beamsplitter to divide the optical source into two or more optical beams which are directed at the linear detector arrays. Filter trays are positioned in the focal planes of the optical beams so that the beams pass through the filter trays prior to impinging upon the detector arrays. Multiple filters are placed on the filter trays. Linear actuators positioned adjacent the filter trays translate the trays across the focal planes of the optical beams so that individual filters are positioned in the path of beams such that those frequencies of the beams that fall within the spectral ranges of the individual bandpass filter through which it passes may be detected by the detector arrays for further examination and analysis.

Richard, H. L.↗

Image quality against metric capability of an aerial camera

Glass plate targets containing multiple contrast three bar patterns and a military standard resolution target were photographed through a light-source collimator-camera system. The glass plate targets and images were then scanned. Through a computer plotting program selected portions of the scanned items were presented. The plots were then measured and analyzed to obtain information of image quality parameters and effects. The measurement errors are discussed together with aspects of resolution determination.

Ghosh, S. K.↗

A study of application of remote sensing to river forecasting. Volume 2: Detailed technical report, NASA-IBM streamflow forecast model user's guide

The Model is described along with data preparation, determining model parameters, initializing and optimizing parameters (calibration) selecting control options and interpreting results. Some background information is included, and appendices contain a dictionary of variables, a source program listing, and flow charts. The model was operated on an IBM System/360 Model 44, using a model 2250 keyboard/graphics terminal for interactive operation. The model can be set up and operated in a batch processing mode on any System/360 or 370 that has the memory capacity. The model requires 210K bytes of core storage, and the optimization program, OPSET (which was used previous to but not in this study), requires 240K bytes. The data band for one small watershed requires approximately 32 tracks of disk storage.

Source record↗

Comparison of layer thickness as observed by Nimbus E microwave spectrometer and by radiosonde

Atmospheric layer thicknesses observed by the microwave spectrometer of the Nimbus E satellite are compared with radiosonde-derived thicknesses for selected short periods. An average 45 m rms discrepancy is found for the 100-50 kPa layer, and several sources of this discrepancy are quantified in the following way. Correlation coefficients between pairs of spectrometer observations and between pairs of radiosonde observations are each extrapolated to zero separation distance to provide measures of instrument noise. Microwave spectrometer noise is found to be 16 m rms and radiosonde noise 23 m rms. Estimates are also made of those portions of the total discrepancy which are due to different resolution of the sensors (about 15 m rms) and real spatial and temporal variation of the atmosphere between observations (about 17 m rms).

Wilcox, R. W.↗

Cable-fault locator

Inexpensive system automatically indicates location of short-circuited section of power cable. Monitor does not require that cable be disconnected from its power source or that test signals be applied. Instead, ground-current sensors are installed in manholes or at other selected locations along cable run. When fault occurs, sensors transmit information about fault location to control center. Repair crew can be sent to location and cable can be returned to service with minimum of downtime.

Cason, R. L.↗

Block 4 solar cell module design and test specification for residential applications

Near-term design, qualification and acceptance requirements are provided for terrestrial solar cell modules suitable for incorporation in photovoltaic power sources (2 kW to 10 kW) applied to single family residential installations. Requirement levels and recommended design limits for selected performance criteria are specified for modules intended principally for rooftop installations. Modules satisfying the requirements of this specification fall into one of two categories, residential panel or residential shingle, both meeting general performance requirements plus additional category peculiar constraints.

Source record↗

Photofragmentation-laser induced fluorescence - A new method for detecting atmospheric trace gases

A new method for the in situ detection of nonfluorescing molecular species is proposed: photofragmentation-laser induced fluorescence (PF-LIF). In this approach, the species to be detected is first laser photolyzed at a wavelength lambda (1), producing one or more vibrationally excited photofragments. Before vibrational relaxation occurs, one of these photofragments is pumped into a bonding excited state by a second laser pulse centered at wavelength lambda (2). Fluorescence is sampled at a wavelength lambda (3), where lambda (3) is less then lambda (2) and lambda (1). This pumping configuration thus permits massive discrimination against Rayleigh and Raman scattering as well as white noise fluorescence from the laser wavelengths lambda (1) and lambda (2). The technique should be both highly sensitive and selective for numerous atmospheric trace gases. Specific sampling schemes for detecting NO2, NO3, and HNO2 are proposed. Various noise sources and chemical interferences are discussed. Specific calculations that estimate the sensitivity of the PF-LIF system for detecting NO2, NO3, and HNO2 are given.

Rodgers, M. O.↗

Automatic thermal control switches

Two automatic, flexible connection thermal control switches have been designed and tested in a thermal vacuum facility and in the Get Away Special (GAS) container flown on the third Shuttle flight. The switches are complementary in that one switch passes heat when the plate on which it is mounted exceeds some selected temperature and the other switch will pass heat only when the mounting plate temperature is below the selected value. Both switches are driven and controlled by phase-change capsule motors and require no other power source or thermal sensors.

Wing, L. D.↗

Measuring Excess Noise in SDL's

New instrument gives quantitive information on "excess noise" in semiconductor-diode laser (SDL's). By proper selection of detector, instrument tests any SDL from visible wavelengths through thermal infrared. Lasers determine excess noise in SKL source by measuring photocurrent generated in photodetector exposed first to reference laser then to SKL under test.

Katzberg, S. J.↗

Ionosphere

The original interest in an ionosphere on Jupiter was generated by the discovery of strong radio-frequency emissions at approximately 20 MHz which were thought to be plasma frequencies associated with Jupiter's ionosphere. The ionosphere of Jupiter provides a means to couple the magnetosphere to the atmosphere by virtue of its high conductivity and collisional interaction with the neutral atmosphere. The Pioneer and Voyager have provided direct measurements of profiles of electron concentration at selected locations on Jupiter. Attention is given to basic principles regarding the characteristics of the Jovian ionosphere, the ionization sources, aspects of ion recombination, ion chemistry, observations of Jupiter's ionosphere, the structure of Jupiter's upper atmosphere, and questions of ionospheric modeling. On the basis of the Pioneer and Voyager observations it appears that Jupiter's ionosphere and thermosphere undergo significant solar cycle changes.

Strobel, D. F.↗