Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “soft materials”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 847 records · Page 47

Property Measurements of the NaCl-PuCl 3 Molten Salt System

Thermal properties of several compositions of the binary NaCl-PuCl 3 salt were measured to confirm the eutectic composition and provide high quality data for use by MSR developers. The PuCl 3 was generated by reducing PuO 2 to plutonium metal in the presence of calcium metal and then chlorinating the metallic plutonium with NH 4 Cl. The resulting PuCl 3 was used to make seven binary NaCl-PuCl 3 compositions with between 59.9 mol % PuCl 3 (Salt 1) and 20.0 mol % PuCl 3 (Salt 7). The eutectic temperature was measured to be 457 ± 4 °C by onset determination in DSC analyses of the seven mixtures, which is consistent with the values in the literature. Additional transitions were observed at approximately 332 and 363 °C in analyses of the PuCl 3 -rich compositions (Salts 1-3) at about 376 and 439 °C in analyses the Na-rich compositions (Salts 4-7). The solid state heat capacity decreased with increasing PuCl 3 content. The liquid state heat capacity was measured for Salt 3 (37.4 mol % PuCl 3 ) and Salt 4 (38.3 mol % PuCl 3 ). A higher heat capacity was measured for Salt 4 and measurements with both salts showed a positive correlation with temperature between 520 and 730 °C. Cells fabricated from nickel and molybdenum for use in DSC measurements at high temperatures could not be adequately sealed because these materials are not sufficiently malleable, even after high temperature annealing. It is recommended that future development focus on corrosion-resistant materials that have mechanical and thermal properties similar to the commercially available gold cells, such as Pt-Rh (80–20) and pure platinum. Those materials are chemically inert, soft, and malleable like gold, but have melting temperatures higher than 1000 °C (Rakhtsaum, 2013). Use of the Pt-Rh alloy should be evaluated first based on superior machinability for making precision parts and its current use in commercial DSC high temperature crucibles. The commercial Pt-Rh cells are not hermetically sealable, but it is expected that cells made from thinner stock can be sealed.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Large-Scale Reactive Extrusion Deposition of Sparse Infill Structures with Solid Perimeters

Large-scale additive manufacturing of reactive polymer systems offers significant improvements over thermoplastics through improved mechanical properties, faster deposition rates, and deposition at ambient temperatures. At ambient temperatures, the resin exists as a viscoelastic liquid which require additional additives for improved rigidity and bead stability. These filler-reinforced resins, or yield stress fluids, are soft solid-like materials able to withstand compressive forces from successive layer deposition until curing leads to bead solidification. When bead deposition is unsupported by previous layers, as is the case when bridging a gap, the creep due to gravitational loading can lead to bead instabilities which result in excessive sagging or bead breakage. These bead instabilities are material dependent and susceptible to changes in filler composition and temperature rises due to exothermic reactions. This work implements a design solution for bridging sparse infill patterns in additively manufactured parts which are essential in the reduction of weight. A series of span tests over a range of distances, as multiples of nozzle diameter, were conducted to determine the critical distance where a bead would break. Additional layer depositions determined the number of layers needed to recover from sagging effects. This recovery was essential in the transition of sparse infill to solid infill printing, where solid infill is milled for a smooth surface finish. Without the capability of sparse-solid transition, additively manufactured parts would require further surface treatments such as spray coating, adding to cost and increasing production time. A standard domed-mold geometry is presented to show the success of this printing process.

Hershey, Christopher↗

Development of a Stress Sensor for In-Situ High-Pressure Deformation Experiments Using Radial X-Ray Diffraction

We developed a stress sensor for in-situ deformation experiments using synchrotron radial X-ray diffraction. This stress sensor provided nearly diffraction-plane-independent stress that, when used in series with a sample, reduced the uncertainty of the average stress estimation acting on a sample. Here, we present the results of a study where pyrope was used as a stress sensor. Using a Deformation-DIA (D-DIA) high-pressure deformation apparatus, pyrope, olivine and alumina were deformed in the same run/cell assembly placed in series along the compression direction. Deformation experiments were conducted at pressures between 4 and 5 GPa and temperatures between 730 and 1273 K with strain-rates between 10 –5 and 10 –6 s –1 . Stresses estimated from various (hkl) planes in pyrope were nearly the same; i.e., pyrope is plastically isotropic with ≤10 % variation with (hkl). However, stresses from various (hkl) planes in olivine and alumina varied by approximately a factor of 3. Comparisons between average stresses inferred from pyrope and those from different diffraction planes in olivine and alumina showed that the average stress in these materials evolved from low-end stress, estimated from various (hkl) planes at small strain, to high-end stress at a large strain. This suggests that the rate-controlling slip system in these materials changes from the soft to the hard slip system with strain.

58 GEOSCIENCES↗

Wrinkling phenomenon in structures. II - Wrinkling criteria

The wrinkling phenomenon in elasticity is mathematically defined and described as a special type of instability associated with the loss of hyperbolicity of the governing equations when some of the characteristic speeds of elastic wave propagation become imaginary. The developed criteria of wrinkling are applied to such structural elements as membranes, strings, soft shells, soft rods, and laminated material. The cause of wrinkling in these elements is due to compression in longitudinal directions that exceeds the through-the-thickness shear modulus. For elements with internal fluid flow the critical compression is reduced due to the destabilizing effect of the flow. The most effective mathematical analysis technique is a combination of tensor analysis and index notations.

Zak, M.↗

Noise transmission of double wall composite shells

This paper describes analytical studies of noise transmission of double wall laminated composite cylindrical shells of finite extent. The main objective is to estimate structureborne noise generated by the concentrated random forces. The theoretical solutions of the governing acoustic-structural equations are obtained utilizing modal decomposition. Results indicate that from the viewpoint of noise attenuation the composite shell does not seem to offer advantage over an aluminum shell. However, the orientation of the fibers and the material characteristics of the soft viscoelastic core can be tailored to meet the specific needs of noise attenuation.

Vaicaitis, R.↗

Nanostructure and compositional segregation of soft magnetic FeNi-based nanocomposites with multiple nanocrystalline phases

Soft magnetic metal amorphous nanocomposite alloys are produced through rapid solidification and thermal annealing yielding nanocrystals embedded within an amorphous precursor. Similar free energies in Co-rich and FeNi-based alloy systems result in multiple nanocrystalline phases being formed during devitrification. Studies of multi-phase crystallization processes have been reported for Co-rich alloys but relatively few have investigated FeNi-based systems. A detailed characterization of compositional partitioning and microstructure of an optimally annealed FeNi-based MANC (Fe70Ni30)80Nb4Si2B14 alloy is presented through complementary high-resolution transmission electron microscopy (HRTEM) and atom probe tomography (APT). HRTEM demonstrates orientation relationships between FCC and BCC nanocrystals, suggesting heterogeneous nucleation of nanocrystals in the amorphous matrix or a cooperative mechanism of nucleation between BCC and FCC nanocrystallites. APT results show evidence for (i) the segregation of Fe and Ni between nanocrystals of different phases, (ii) B partitioning to the amorphous phase, and (iii) an Nb-enriched shell surrounding nanocrystals.

soft magnetic materials↗

Magnetic Anisotropy and Stress Dependent Epoxy Wetting in FeNi-based Metal Amorphous Nanocomposite

Recently developed FeNi-based metal amorphous nanocomposites (MANCs) used in high-speed motors (HSMs) exhibit reduced eddy current losses while maintaining good mechanical properties and glass-forming abilities. Magnetic anisotropy in (Fe 70 Ni 30 ) 80 Nb 4 B 14 Si 2 amorphous magnetic ribbon (AMR) in the as-cast state and upon conventional (T CA ) and strain (T SA ) annealing heat treatment is investigated. From ribbon samples in as-cast condition, quenched in stress from planar flow casting (PFC) induced as-cast curvature derived uniaxial magnetic anisotropy. Stress relief by conventional furnace annealing at T CA > 350 °C achieved isotropic properties in the bulk. Annealing about the primary crystallization temperature, T CA ~ 450 °C, resulted in the formation of both FCC and BCC nanocrystallites and evolution to isotropic bulk magnetic properties confirming the random anisotropy model. In samples strain annealed at T SA = 440 °C at various tensions, relatively large controlled induced uniaxial anisotropy is achieved. The largest magnetic anisotropy occurs in annealing under the stress of 250 MPa yielding an anisotropy field of 7.1 x 10 4 A/m. Surface anisotropy observed by MOKE differs from bulk anisotropy due to image contrast from closure domains. Epoxy coatings are important for improved bonding, mechanical properties, and resistivity in tape-wound MANC cores for HSMs. Using a sessile droplet method, the equilibrium contact angle of an epoxy droplet on a tensile stress annealed MANC exhibits stress dependent surface energies. Anisotropic wetting in FeNi-based MANC heat treated at T CA = 440 °C mimics surface magnetic anisotropy observed by MOKE.

soft magnetic materials↗

Helium Ion Microscopy

Nanotechnology research led to the development of various instruments to be used for imaging or fabrication. The helium ion microscope (HIM) became available in 2006 but quickly gained popularity. Its unique gas field ion source enables high-resolution imaging, nanofabrication, direct write, and the recent combination with a secondary ion mass spectrometer offers chemical imaging with ~15 nm resolution. Particularly attractive are the small interaction volume of He and Ne (the two gases offered), small beam spot size, and a moderate sputtering rate. Additionally, the HIM is an excellent imaging tool for insulating samples in soft, polymeric, and biological materials. It can be expected that helium ion microscopy will continue to have a strong influence on broad range of scientific disciplines, including chemistry, materials science, and biology.This chapter aims at providing an overview of the current status of HIM for imaging, analysis, and nanofabrication. It introduces the reader to key components of the instrument, theoretical background, and latest results in the areas of imaging, material fabrication, and chemical analysis capabilities of helium ion microscopy.

Belianinov, Alex↗

Extended Sleeve Products Allow Control and Monitoring of Process Fluid Flows Inside Shielding, Behind Walls and Beneath Floors - 13041

Throughout power generation, delivery and waste remediation, the ability to control process streams in difficult or impossible locations becomes increasingly necessary as the complexity of processes increases. Example applications include radioactive environments, inside concrete installations, buried in dirt, or inside a shielded or insulated pipe. In these situations, it is necessary to implement innovative solutions to tackle such issues as valve maintenance, valve control from remote locations, equipment cleaning in hazardous environments, and flow stream analysis. The Extended Sleeve family of products provides a scalable solution to tackle some of the most challenging applications in hazardous environments which require flow stream control and monitoring. The Extended Sleeve family of products is defined in three groups: Extended Sleeve (ESV), Extended Bonnet (EBV) and Instrument Enclosure (IE). Each of the products provides a variation on the same requirements: to provide access to the internals of a valve, or to monitor the fluid passing through the pipeline through shielding around the process pipe. The shielding can be as simple as a grout filled pipe covering a process pipe or as complex as a concrete deck protecting a room in which the valves and pipes pass through at varying elevations. Extended Sleeves are available between roughly 30 inches and 18 feet of distance between the pipeline centerline and the top of the surface to which it mounts. The Extended Sleeve provides features such as ± 1.5 inches of adjustment between the pipeline and deck location, internal flush capabilities, automatic alignment of the internal components during assembly and integrated actuator mounting pads. The Extended Bonnet is a shorter fixed height version of the Extended Sleeve which has a removable deck flange to facilitate installation through walls, and is delivered fully assembled. The Instrument Enclosure utilizes many of the same components as an Extended Sleeve, yet allows the installation of process monitoring instruments, such as a turbidity meter to be placed in the flow stream. The basis of the design is a valve body, which, rather than having a directly mounted bonnet has lengths of concentric pipe added, which move the bonnet away from the valve body. The pipe is conceptually similar to an oil field well, with the various strings of casing, and tubing installed. Each concentric pipe provides a required function, such as the outermost pipes, the valve sleeve and penetration sleeve, which provide structural support to the deck flange. For plug valve based designs, the next inner pipe provides compression on the environmental seals at the top of the body to bonnet joint, followed by the innermost pipe which provides rotation of the plug, in the same manner as an extended stem. Ball valve ESVs have an additional pipe to provide compressive loading on the stem packing. Due to the availability of standard pipe grades and weights, the product can be configured to fit a wide array of valve sizes, and application lengths, with current designs as short as seven inches and as tall as 18 feet. Central to the design is the requirement for no special tools or downhole tools to remove parts or configure the product. Off the shelf wrenches, sockets or other hand tools are all that is required. Compared to other products historically available, this design offers a lightweight option, which, while not as rigidly stiff, can deflect compliantly under extreme seismic loading, rather than break. Application conditions vary widely, as the base product is 316 and 304 stainless steel, but utilizes 17-4PH, and other allows as needed based on the temperature range and mechanical requirements. Existing designs are installed in applications as hot as 1400 deg. F, at low pressure, and separately in highly radioactive environments. The selection of plug versus ball valve, metal versus soft seats, and the material of the seals and seats is all dependent on the application requirements. The design of the Extended Sleeve family of products provides a platform which solves a variety of accessibility problems associated with controlling process flow streams in remote, hard to reach locations in harsh environments. Installation of the equipment described has shown to allow access to flow streams that otherwise would require exceptional means to access and control. The Extended Sleeve family of products provides a scalable solution to both control and monitor process fluid flow through shielding, walls or floors when direct connection is advantageous. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Material separation in x-ray CT with energy resolved photon-counting detectors

Purpose: The objective of the study was to demonstrate that, in x-ray computed tomography (CT), more than two types of materials can be effectively separated with the use of an energy resolved photon-counting detector and classification methodology. Specifically, this applies to the case when contrast agents that contain K-absorption edges in the energy range of interest are present in the object. This separation is enabled via the use of recently developed energy resolved photon-counting detectors with multiple thresholds, which allow simultaneous measurements of the x-ray attenuation at multiple energies. Methods: To demonstrate this capability, we performed simulations and physical experiments using a six-threshold energy resolved photon-counting detector. We imaged mouse-sized cylindrical phantoms filled with several soft-tissue-like and bone-like materials and with iodine-based and gadolinium-based contrast agents. The linear attenuation coefficients were reconstructed for each material in each energy window and were visualized as scatter plots between pairs of energy windows. For comparison, a dual-kVp CT was also simulated using the same phantom materials. In this case, the linear attenuation coefficients at the lower kVp were plotted against those at the higher kVp. Results: In both the simulations and the physical experiments, the contrast agents were easily separable from other soft-tissue-like and bone-like materials, thanks to the availability of the attenuation coefficient measurements at more than two energies provided by the energy resolved photon-counting detector. In the simulations, the amount of separation was observed to be proportional to the concentration of the contrast agents; however, this was not observed in the physical experiments due to limitations of the real detector system. We used the angle between pairs of attenuation coefficient vectors in either the 5-D space (for non-contrast-agent materials using energy resolved photon-counting acquisition) or a 2-D space (for contrast agents using energy resolved photon-counting acquisition and all materials using dual-kVp acquisition) as a measure of the degree of separation. Compared to dual-kVp techniques, an energy resolved detector provided a larger separation and the ability to separate different target materials using measurements acquired in different energy window pairs with a single x-ray exposure. Conclusions: We concluded that x-ray CT with an energy resolved photon-counting detector with more than two energy windows allows the separation of more than two types of materials, e.g., soft-tissue-like, bone-like, and one or more materials with K-edges in the energy range of interest. Separating material types using energy resolved photon-counting detectors has a number of advantages over dual-kVp CT in terms of the degree of separation and the number of materials that can be separated simultaneously.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Theoretical Studies on the Electronic Structures and Properties of Complex Ceramic Crystals and Novel Materials

This project is a continuation of a long program supported by the Office of Basic Energy Science in the Office of Science of DOE for many years. The final three-year continuation started on November 1, 2005 with additional 1 year extension to October 30, 2009. The project was then granted a two-year No Cost Extension which officially ended on October 30, 2011. This report covers the activities within this six year period with emphasis on the work completed within the last 3 years. A total of 44 papers with acknowledgement to this grant were published or submitted. The overall objectives of this project are as follows. These objectives have been evolved over the six year period: (1) To use the state-of-the-art computational methods to investigate the electronic structures of complex ceramics and other novel crystals. (2) To further investigate the defects, surfaces/interfaces and microstructures in complex materials using large scale modeling. (3) To extend the study on ceramic materials to more complex bioceramic crystals. (4) To initiate the study on soft condensed matters including water and biomolecules. (5) To focus on the spectroscopic studies of different materials especially on the ELNES and XANES spectral calculations and their applications related to experimental techniques. (6) To develop and refine computational methods to be effectively executed on DOE supercomputers. (7) To evaluate mechanical properties of different crystals and those containing defects and relate them to the fundamental electronic structures. (8) To promote and publicize the first-principles OLCAO method developed by the PI (under DOE support for many years) for applications to large complex material systems. (9) To train a new generation of graduate students and postdoctoral fellows in modern computational materials science and condensed matter physics. (10) To establish effective international and domestic collaborations with both experimentalists and theorists in materials research. Because of the large amount of work accomplished, a diverse class of materials covered and the desire for an easier reporting process, this report will list six categories (A to F) of major accomplishments and findings under the following headings with references to the published papers under DOE support. These six categories obviously have heavy overlaps. A complete list of published papers follows the brief description on each category. Each paper also indicates to which of the six categories the main accomplishment it belongs to. A. Electronic structure of complex and novel crystals B. Impurities, surfaces, interfaces and microstructures in ceramics C. Structures and properties of complex bioceramics D. Soft condensed matters E. Spectroscopic characterizations, XANES and ELNES spectroscopy F. Large-scale simulations.

36 MATERIALS SCIENCE↗

Should I stay or should I flow? An exploration of phase‐separated metallosupramolecular liquid crystal polymers

Abstract Dynamic liquid crystalline polymers (dLCPs) incorporate both liquid crystalline mesogens and dynamic bonds into a single polymeric material. These dual functionalities impart order‐dependent thermo‐responsive mechano‐optical properties and enhanced reprocessability/programmability enabling their use as soft actuators, adaptive adhesives, and damping materials. While many previous works studying dynamic LCPs utilize dynamic covalent bonds, metallosupramolecular bonds provide a modular platform where a series of materials can be accessed from a single polymeric feedstock through the variation of the metal ion used. A series of dLCPs were prepared by the addition of metal salts to a telechelic 2,6‐bisbenzimidazolylpyridine (Bip) ligand endcapped LCP to form metallosupramolecular liquid crystal polymers (MSLCPs). The resulting MSLCPs were found to phase separate into hard and soft phases which aids in their mechanical robustness. Variations of the metal salts used to access these materials allowed for control of the thermomechanical, viscoelastic, and adhesive properties with relaxations that can be tailored independently of the mesogenic transition. This work demonstrates that by accessing phase separation through the incorporation of metallosupramolecular moieties, highly processable yet robust MSLCP materials can be realized. This class of materials opens the door to LCPs with bulk flow behavior that can also be utilized as multi‐level adhesives.

Chemistry↗

Design Tool for Cryogenic Thermal Insulation Systems

Thermal isolation of low-temperature systems from ambient environments is a constant issue faced by practitioners of cryogenics. For energy-efficient systems and processes to be realized, thermal insulation must be considered as an integrated system, not merely an add-on element. A design tool to determine the performance of insulation systems for comparative trade-off studies of different available material options was developed. The approach is to apply thermal analysis to standard shapes (plane walls, cylinders, spheres) that are relatively simple to characterize with a one-dimensional analytical or numerical model. The user describes the system hot and cold boundary geometry and the operating environment. Basic outputs such as heat load and temperature profiles are determined. The user can select from a built-in insulation material database or input user defined materials. Existing information has been combined with the new experimental thermal conductivity data produced by the Cryogenics Test Laboratory for cryogenic and vacuum environments, including high vacuum, soft vacuum, and no vacuum. Materials in the design tool include multilayer insulation, aerogel blankets, aerogel bulk-fill, foams, powders, composites, and other insulation system constructions. A comparison of the design tool to a specific composite thermal insulation system is given.

aerogels↗

Uniformity and transmission of proportional counter window materials for use with AXAF

The X-ray detection system used to calibrate the Advanced X-ray Astrophysics Facility (AXAF) mirrors will include gas flow and sealed proportional counters. To meet the ultimate 1 percent goal of the calibration project, the transmission and uniformity of the windows must be well known for the soft X-ray wavelengths involved. Various window materials for use with proportional counters are examined for transmission at X-ray wavelengths in the range of 0.1 to 5.9 keV. These include the usual window materials (polypropylene and beryllium), as well as materials only recently employed for detector applications (polyimide and diamond). The transmission uniformity of beryllium at 1.49 keV is examined with a microchannel plate detector, producing a 'shadowgraph' of the window material illuminated with soft X-rays. This technique allows us to investigate nonuniformities on a spatial scale of about .2 mm.

Flanagan, K.↗

Soft Robotics

This description of “soft robotics” is not intended to be a conventional review, in the sense of a comprehensive technical summary of a developing field. Rather, its objective is to describe soft robotics as a new field—one that offers opportunities to chemists and materials scientists who like to make “things” and to work with macroscopic objects that move and exert force. It will give one (personal) view of what soft actuators and robots are, and how this class of soft devices fits into the more highly developed field of conventional “hard” robotics. It will also suggest how and why soft robotics is more than simply a minor technical “tweak” on hard robotics and propose a unique role for chemistry, and materials science, in this field. Finally, soft robotics is, at its core, intellectually and technologically different from hard robotics, both because it has different objectives and uses and because it relies on the properties of materials to assume many of the roles played by sensors, actuators, and controllers in hard robotics.

47 OTHER INSTRUMENTATION↗

Initial Results of Image-Guided Percutaneous Ablation as Second-Line Treatment for Symptomatic Vascular Anomalies

PurposeThe purpose of this study was to determine the feasibility, safety, and early effectiveness of percutaneous image-guided ablation as second-line treatment for symptomatic soft-tissue vascular anomalies (VA).Materials and MethodsAn IRB-approved retrospective review was undertaken of all patients who underwent percutaneous image-guided ablation as second-line therapy for treatment of symptomatic soft-tissue VA during the period from 1/1/2008 to 5/20/2014. US/CT- or MRI-guided and monitored cryoablation or MRI-guided and monitored laser ablation was performed. Clinical follow-up began at one-month post-ablation.ResultsEight patients with nine torso or lower extremity VA were treated with US/CT (N = 4) or MRI-guided (N = 2) cryoablation or MRI-guided laser ablation (N = 5) for moderate to severe pain (N = 7) or diffuse bleeding secondary to hemangioma–thrombocytopenia syndrome (N = 1). The median maximal diameter was 9.0 cm (6.5–11.1 cm) and 2.5 cm (2.3–5.3 cm) for VA undergoing cryoablation and laser ablation, respectively. Seven VA were ablated in one session, one VA initially treated with MRI-guided cryoablation for severe pain was re-treated with MRI-guided laser ablation due to persistent moderate pain, and one VA was treated in a planned two-stage session due to large VA size. At an average follow-up of 19.8 months (range 2–62 months), 7 of 7 patients with painful VA reported symptomatic pain relief. There was no recurrence of bleeding at five-year post-ablation in the patient with hemangioma–thrombocytopenia syndrome. There were two minor complications and no major complications.ConclusionImage-guided percutaneous ablation is a feasible, safe, and effective second-line treatment option for symptomatic VA.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

EFFECT OF ENDOSPERM HARDNESS ON AN ETHANOL PROCESS USING A GRANULAR STARCH HYDROLYZING ENZYME

Granular starch hydrolyzing enzymes (GSHE) can hydrolyze starch at low temperature (32°C). The dry grind process using GSHE (GSH process) has fewer unit operations and no changes in process conditions (pH 4.0 and 32°C) compared to the conventional process because it dispenses with the cooking and liquefaction step. In this study, the effects of endosperm hardness, protease, urea, and GSHE levels on GSH process were evaluated. Ground corn, soft endosperm, and hard endosperm were processed using two GSHE levels (0.1 and 0.4 mL per 100 g ground material) and four treatments of protease and urea addition. Soft and hard endosperm materials were obtained by grinding and sifting flaking grits from a dry milling pilot plant; classifications were confirmed using scanning electron microscopy. During 72 h of simultaneous granular starch hydrolysis and fermentation (GSHF), ethanol and glucose profiles were determined using HPLC. Soft endosperm resulted in higher final ethanol concentrations compared to ground corn or hard endosperm. Addition of urea increased final ethanol concentrations for soft and hard endosperm. Protease addition increased ethanol concentrations and fermentation rates for soft endosperm, hard endosperm, and ground corn. The effect of protease addition on ethanol concentrations and fermentation rates was most predominant for soft endosperm, less for hard endosperm, and least for ground corn. Samples (soft endosperm, hard endosperm, or corn) with protease resulted in higher (1.0% to 10.5% v/v) ethanol concentration compared to samples with urea. The GSH process with protease requires little or no urea addition. For fermentation of soft endosperm, GSHE dose can be reduced. Due to nutrients (lipids, minerals, and soluble proteins) present in corn that enhance yeast growth, ground corn fermented faster at the beginning than hard and soft endosperm.

09 BIOMASS FUELS↗