Analysis Methodology for Balancing Authority Cooperation in High Penetration of Variable Generation

With the rapidly growing penetration level of wind and solar generation, the challenges of managing variability and the uncertainty of intermittent renewable generation become more and more significant. The problem of power variability and uncertainty gets exacerbated when each balancing authority (BA) works locally and separately to balance its own subsystem. The virtual BA concept means various forms of collaboration between individual BAs must manage power variability and uncertainty. The virtual BA will have a wide area control capability in managing its operational balancing requirements in different time frames. This coordination results in the improvement of efficiency and reliability of power system operation while facilitating the high level integration of green, intermittent energy resources. Several strategies for virtual BA implementation, such as ACE diversity interchange (ADI), wind only BA, BA consolidation, dynamic scheduling, regulation and load following sharing, extreme event impact study are discussed in this report. The objective of such strategies is to allow individual BAs within a large power grid to help each other deal with power variability. Innovative methods have been developed to simulate the balancing operation of BAs. These methods evaluate the BA operation through a number of metrics — such as capacity, ramp rate, ramp duration, energy and cycling requirements — to evaluate the performances of different virtual BA strategies. The report builds a systematic framework for evaluating BA consolidation and coordination. Results for case studies show that significant economic and reliability benefits can be gained. The merits and limitation of each virtual BA strategy are investigated. The report provides guidelines for the power industry to evaluate the coordination or consolidation method. The application of the developed strategies in cooperation with several regional BAs is in progress for several off-spring projects.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Calendar Year 2008 Groundwater Monitoring Report, U.S. Department of Energy Y-12 National Security Complex, Oak Ridge, Tennessee

This report contains the groundwater and surface water monitoring data that were obtained during calendar year (CY) 2008 at the U.S. Department of Energy (DOE) Y-12 National Security Complex (hereafter referenced as Y-12) on the DOE Oak Ridge Reservation (ORR) in Oak Ridge, Tennessee. The CY 2008 monitoring data were obtained from wells, springs, and surface water sampling locations in three hydrogeologic regimes at Y-12 (Figure A.1). The Bear Creek Hydrogeologic Regime (Bear Creek Regime) encompasses a section of Bear Creek Valley (BCV) between the west end of Y-12 and the west end of the Bear Creek Watershed (directions are in reference to the Y-12 grid system). The Upper East Fork Poplar Creek Hydrogeologic Regime (East Fork Regime) encompasses the Y-12 industrial facilities and support structures in BCV. The Chestnut Ridge Hydrogeologic Regime (Chestnut Ridge Regime) encompasses a section of Chestnut Ridge directly south of Y-12. Section 2 of this report provides background information pertinent to groundwater and surface water quality monitoring in each hydrogeologic regime, including the topography and bedrock geology, surface water drainage, groundwater system, and extent of groundwater contamination. The CY 2008 groundwater and surface water monitoring data in this report were obtained from sampling and analysis activities implemented under the Y-12 Groundwater Protection Program (GWPP) managed by Babcock & Wilcox Technical Services Y-12, LLC (B&W Y-12) and from sampling and analysis activities implemented under several monitoring programs managed by Bechtel Jacobs Company LLC (BJC). Cooperative implementation of the monitoring programs directed by the Y-12 GWPP and BJC (i.e., coordinating sample collection and sharing data) ensures that the CY 2008 monitoring results fulfill requirements of all the applicable monitoring drivers with no duplication of sampling and analysis efforts. Section 3 of this report contains a summary of information regarding the groundwater and surface water sampling and analysis activities implemented under the Y-12 GWPP including sampling locations and frequency; quality assurance (QA)/quality control (QC) sampling; sample collection and handling; field measurements and laboratory analytes; data management and data quality objective (DQO) evaluation; and groundwater elevation monitoring. However, this report does not include equivalent QA/QC or DQO evaluation information regarding the groundwater and surface water sampling and analysis activities associated with the monitoring programs implemented by BJC. Such details are deferred to the respective programmatic plans and reports issued by BJC (see Section 3.0).

54 ENVIRONMENTAL SCIENCES↗

The Modern Research Data Portal: A Design Pattern for Networked, Data-Intensive Science

Here we describe best practices for providing convenient, high-speed, secure access to large data via research data portals. We capture these best practices in a new design pattern, the Modern Research Data Portal, that disaggregates the traditional monolithic web-based data portal to achieve orders-of-magnitude increases in data transfer performance, support new deployment architectures that decouple control logic from data storage, and reduce development and operations costs. We introduce the design pattern; explain how it leverages high-performance Science DMZs and cloud-based data management services; review representative examples at research laboratories and universities, including both experimental facilities and supercomputer sites; describe how to leverage Python APIs for authentication, authorization, data transfer, and data sharing; and use coding examples to demonstrate how these APIs can be used to implement a range of research data portal capabilities. Sample code at a companion web site, https://docs.globus.org/mrdp, provides application skeletons that readers can adapt to realize their own research data portals.

96 KNOWLEDGE MANAGEMENT AND PRESERVATION↗

The Modern Research Data Portal: a design pattern for networked, data-intensive science

We describe best practices for providing convenient, high-speed, secure access to large data via research data portals. Here, we capture these best practices in a new design pattern, the Modern Research Data Portal, that disaggregates the traditional monolithic web-based data portal to achieve orders-of-magnitude increases in data transfer performance, support new deployment architectures that decouple control logic from data storage, and reduce development and operations costs. We introduce the design pattern; explain how it leverages high-performance data enclaves and cloud-based data management services; review representative examples at research laboratories and universities, including both experimental facilities and supercomputer sites; describe how to leverage Python APIs for authentication, authorization, data transfer, and data sharing; and use coding examples to demonstrate how these APIs can be used to implement a range of research data portal capabilities. Sample code at a companion web site, https://docs.globus.org/mrdp , provides application skeletons that readers can adapt to realize their own research data portals.

97 MATHEMATICS AND COMPUTING↗

A dynamic model of once-through steam generator (OTSG) for prototypical advanced reactor - 374

new design of Small Modular Reactor, the Prototypical Advanced Reactor (PAR), features two sodium primary systems each connected to dedicated steam generators (SGs) and sharing a balance of plant (BOP) system. PAR adopts once-through steam generators (OTSG) for its compact structure. The existence of superheated steam in a OTSG improves turbine design by eliminating the need of bulky moisture separator in SG. The two cores and SGs' design enable PAR to adjust power flexibly, as a result, introduce more challenges to the control. Therefore, a fast simulation model with high accuracy OTSG model is needed. In this paper, a dynamic model is built for OTSG of PAR based on the conservation of mass, momentum, and energy. The OTSG is simulated as lumped pipe and divided into subcooled, evaporating, and superheated regions by moving boundaries. SIMULINK is adopted to this OTSG simulation to be merged into existing PAR system models easily. The steady state results show that key parameters are rational. The 5% step increase of feedwater enthalpy transient demonstrates that the model is capable to respond to the perturbations. Since the basic laws and algebraic method used in this paper are suitable for other fluids, the model can be easily applied to any other OTSG. Future work will also focus on model optimization, merging and improved control. The final aim is to perform full scope realtime simulations for PAR under normal operational transients. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Multi-core processing and scheduling performance in CMS

Commodity hardware is going many-core. We might soon not be able to satisfy the job memory needs per core in the current single-core processing model in High Energy Physics. In addition, an ever increasing number of independent and incoherent jobs running on the same physical hardware not sharing resources might significantly affect processing performance. It will be essential to effectively utilize the multi-core architecture. CMS has incorporated support for multi-core processing in the event processing framework and the workload management system. Multi-core processing jobs share common data in memory, such us the code libraries, detector geometry and conditions data, resulting in a much lower memory usage than standard single-core independent jobs. Exploiting this new processing model requires a new model in computing resource allocation, departing from the standard single-core allocation for a job. The experiment job management system needs to have control over a larger quantum of resource since multi-core aware jobs require the scheduling of multiples cores simultaneously. CMS is exploring the approach of using whole nodes as unit in the workload management system where all cores of a node are allocated to a multi-core job. Whole-node scheduling allows for optimization of the data/workflow management (e.g. I/O caching, local merging) but efficient utilization of all scheduled cores is challenging. Dedicated whole-node queues have been setup at all Tier-1 centers for exploring multi-core processing workflows in CMS. We present the evaluation of the performance scheduling and executing multi-core workflows in whole-node queues compared to the standard single-core processing workflows.

Hernandez, J. M.↗

Modular Controllable Transformers (MCT)

Large Power Transformers (LPTs) are at the heart of the electricity infrastructure and are critical pieces in today’s grid. Aging assets, long turn-around times, transportation delays and dependence on foreign manufacturing for these components have created conditions for points of failure across the system. Moreover, there is no available dynamic control on these passive sections of the grid. For all the automation embedded on the low voltage side of the low voltage side of the system there is absolutely no flexibility on the high voltage side. Changes in power flow patterns are brought about by altering dispatch patterns for generators which requires a coordinated effort and is often time consuming. Traditional FACTS based approaches such as UPFC or HVDC light involve massive modifications to the existing infrastructure. Recent instances of physical attacks on LPTs and the slow recovery process associated with fixing or replacing these damaged units has created an increased awareness for this issue. LPT designs are highly customized owing to specific field requirements. Long lead times coupled with transportation delays make procuring and installing LPTs a lengthy process. In an attempt to minimize the recovery time following an LPT failure, transformer manufacturers have developed mobile transformer units. These units typically consist of either a single-phase or three-phase transformer mounted on a truck and characterized by compact form factors. By reducing the assembly time and transport time these units offer a fast and temporary solution to LPT failures. Several efforts led by DOE, Edison Electric Company (EEI) and North American Electric Reliability Corporation (NERC) have led to the RecX program. RecX transformers consist of single phase transformers transported on specialized assemblies to enable fast restoration and minimal installation time. NERC and EEI have instituted transformer sharing programs like Spare Equipment Database (SED) as well as Spare Transformer Equipment Database (STEP) which encourage utilities to maintain and share a fleet of LPTs. Mobile transformers are typically limited to less than 100 MVA to enable transportation on a trailer. Also, the efficiency of mobile transformer units and RecX transformers is lower since they are temporary solutions. The ideal replacement solution would be one that could utilize a set of standardized transformers while incorporating flexibility to influence metrics like power flow, apparent impedance and voltage profiles. In view of these issues the team at Georgia Tech proposed a concept called Modular Controllable Transformers (MCTs). This project was commissioned as a part of DOE’s Transformer Resiliency and Advance Component (TRAC) program. The approach consists of splitting one large unit rated upwards of 100 MVA with smaller modular, standardized units. Each of these smaller units are augmented with a converter to add power flow, voltage and impedance control. Splitting the power level into multiple units has two important implications. By making smaller units, the transportation times can be reduced drastically. Moreover, even though these units have very specific impedance and other parameters, the augmented converters can make it emulate the unit being replaced. Thus, faster replacement times and added controls are achieved making this an extremely resilient approach. In the event of one modular units failure, the other two controllable units can operate in the most resilient fashion keeping the net system overloads to a minimum. Moreover, for the same probability of failure only a fraction of the system capacity is lost. The converter is augmented on to the tertiary winding of the transformer making it retrofittable in the field without massive modifications to the system. The material proposed in this report highlights design considerations to minimize recovery time as well as results displaying overall improvement in resiliency. The cost analysis of this approach shows significant savings compared to UPFC and HVDC lite based approaches. Extensive analysis was conducted on numerous aspects of this project over the course of this project. Simulation studies were conducted to prove the 5MVA converter design. Challenging BIL constraints and transient issues were addressed over the course of this project. Simulations on EMTP platform presented in consequent sections were used to finely tune the control for the same. A final design for a back-to-back 5MVA neutral-point-clamped (NPC) converter was completed in this project. Furthermore, switching components like high power IGBTs from IXYS Westcode Press-Pack series and ABB Stackpack series were identified for this application. These devices exhibit a blocking voltage of 6.5 kV and a nominal collector current of 900 A. Potential housing options as well as existing commercial option were identified for this converter design. A 56 MVA modular transformer unit was designed with Delta Star Inc. with consultation and inputs from all project members. The transformer cooling systems were chosen to be Oil Natural Air Forced (ONAF) to optimize ease of transport. A full Product Requirement Document (PRD) for the converter and the transformer was generated. The team also investigated key aspects of resiliency and how to quantify the same. A metric was developed to analyze resiliency and numerous simulation cases were presented. Increased (N-1) resiliency and outage resistance was showcased through simulation on the Texas Large scale power system. Dynamic control capabilities were also showcased on numerous system level simulations. An IEEE 30 bus system was used to show the ability of the MCT approach to reduce line congestion. Power flow control; a part of the MCTs abilities, showcased a 29% reduction in transformer loading on the same system. Full control over tie line flows was demonstrated on a modified IEEE 13 bus system. Dynamic LTC capabilities were shown through simulation and were compared to traditional LTCs. Furthermore, the ability of the MCTs to alter apparent transformer impedance was simulated to promote standardization of modular transformer units while retaining the ability to emulate a varied range of impedance characteristics. Thus granular control over power flow, voltages, impedances and was presented. Regulatory analysis conducted by Oak Ridge National Laboratory (ORNL) further bolstered the efficacy of the MCT approach and verified the added resiliency achieved due to this approach. As a conclusion, it was proved that the resilience improvement obtained from using the MCT approach is justified by just one failure in a 30-year period. This means that the benefits obtained from using the MCT approach far outweigh the cost of setting this approach up. As a part of the future efforts, the team is proposing building a (12.47-24) kV/400 kVA scaled down unit to control 5MVA of power flows. Emphasis would be laid on using commercial components to speed up the build of these units. Further the actual transport of the modular transformer unit would be a part of this operation and would provide insight into transportation issues. The approach shows much promise and adds key dynamic control on passive sub transmission and transmission sectors.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Surface Engineering of Nanostructured Energy Materials

All nanostructures share a common feature of large surface-to-volume ratio, which makes surface engineering a vital tool for exploring their new and important applications in many different areas. Particularly, inorganic nanostructures represent a class of intriguing catalysts that can find wide uses in energy conversion, energy storage, and environmental remediation. In this work, a number of surface engineering strategies, including morphology control, defect incorporation, and interface manipulation for tailoring the shape, facet, defect, interfacial property, and composition of nanostructures, aiming at controlling the chemical and physical properties such as energy bandgap and surface energy toward great enhancement in catalytic performance, are discussed.

36 MATERIALS SCIENCE↗

Wild bees and natural enemies prefer similar flower species and respond to similar plant traits

Designing wildflower habitats to support beneficial insects providing pollination and pest control services is important for supporting sustainable crop production. It is often desirable to support both groups of insects, making the selection of resource plants for insect conservation programs more challenging. Moreover, the process of selecting resource plants is complicated by the array of possible options in each region, and the need to provide resources over the entire growing season. Identifying traits shared by resource plants that are attractive to both bees and natural enemies can reduce the need to evaluate new plants in each region, by providing a guide for the types of plants expected to be rewarding to these insects. Using insect visitation data collected from replicated common garden plantings of native wildflower and shrub species from the Great Lakes region of the United States, we found a high degree of correlation between the abundance of bees and natural enemies visiting native plant species. These results were used to identify a set of 15 plant species that can provide resources for these insects throughout the summer. Across all tested species, pollen quantity per flower and the week of bloom were positively correlated with some, but not all, taxonomic groupings of beneficial insects. In contrast, floral area was consistently positively associated with visitation of both natural enemies and wild bees. This trait is easy to document and can allow for efficient local testing of potential resource plants, providing a faster path to implementing insect conservation in working landscapes.

54 ENVIRONMENTAL SCIENCES↗

Improving Primary Frequency Response in Networked Microgrid Operations using Multilayer Perceptron-Driven Reinforcement Learning

Individual microgrids can improve the reliability of power grids during extreme events, and networked microgrids can further improve efficiency through resource sharing and increase the resilience of critical end-use loads. However, networked microgrid operations are subject to large switching transients, which can cause dynamic instability and lead to system collapse. These transients are especially prevalent in microgrids with high penetrations of inverter-connected renewable energy resources, which do not provide the system inertia needed to mitigate the transients. Existing generator controls can be modified to invoke a drop in terminal voltage in response to a frequency deviation, thereby reducing load and improving frequency response. This paper investigates the use of a reinforcement-learning--based controller trained over several switching transient scenarios to modify generator controls during large frequency deviations. Compared to previously used proportional integral controllers, the proposed controller can improve primary frequency response while adapting to changes in system topologies and events.

Radhakrishnan, Nikitha↗

Multiport Converter based Auxiliary Power Supply for Heavy Duty Fuel Cell Power Train

This paper presents a multiport converter (MPC) based power supply to charge the 12 V and 24 V auxiliary batteries in heavy duty (HD) fuel cell (FC) electric vehicle (EV) power train. Compared to conventional auxiliary power supply architectures, the proposed architecture shares the power electronic components of the main power train yet preserves the isolation and all other desirable features of auxiliary power supplies. The proposed auxiliary power supply architecture reduces the requirements of the devices, gate drivers and thermal requirements thereby having potential benefits towards improving the power density, cost and weight of the overall power train. The topology, design parameters and control methodology are discussed, and results are presented to validate the proposed architecture.

Mukherjee, Subho↗

Assessing Inverter-Based Resources Modeling Gaps in Commonly Used Short-Circuit Programs

Future bulk power systems are expected to operate with a high penetration of inverter-based resources (IBR). This is anticipated to fundamentally change the system’s short-circuit behaviors and demand a change in existing transmission line protection settings or schemes. Phasor-domain short circuit programs (e.g., ASPEN, CAPE, and CYME) remain the mainstream tools for developing protection settings. However, the system protection community has shared concerns about the accuracy of IBR models in short-circuit programs. This report compares the performance of existing generic IBR models in short-circuit programs with detailed electro-magnetic transient (EMT) models provided by several different IBR manufacturers in PSCAD, to quantify the short-circuit program’s IBR model accuracy, assess their ability to replicate individual IBR controls such as negative sequence current injections, and identify specific gaps in the existing generic phasor-domain IBR models that are currently available.

42 ENGINEERING↗

Light Regulation of Phytoplankton Growth in San Francisco Bay Studied Using a 3D Sediment Transport Model

In San Francisco Bay (SFB), light availability is largely determined by the concentration of suspended particulate matter (SPM) in the water column. SPM exhibits substantial variation with time, depth, and location. To study how SPM influences light and phytoplankton growth, we coupled a sediment transport model with a hydrodynamic model and a biogeochemical model. The coupled models were used to simulate conditions for the year of 2011 with a focus on northern SFB. For comparison, two simulations were conducted with ecosystem processes driven by SPM concentrations supplied by the sediment transport model and by applying a constant SPM concentration of 20 mg l –1 . The sediment transport model successfully reproduced the general pattern of SPM variation in northern SFB, which improved the chlorophyll-a simulation resulting from the biogeochemical model, with vertically integrated primary productivity varying greatly, from 40 g[C] m –2 year –1 over shoals to 160 g[C] m –2 year –1 in the deep channel. Primary productivity in northern SFB is influenced by euphotic zone depth ( Ze ). Our results show that Ze in shallow water regions (<2 m) is mainly determined by water depth, while Ze in deep water regions is controlled by SPM concentration. As a result, Ze has low (high) values in shallow (deep) water regions. Large (small) differences in primary productivity exist between the two simulations in deep (shallow) water regions. Furthermore, we defined a new parameter F light for “averaged light limitation” in the euphotic zone. The averaged chlorophyll-a concentration in the euphotic zone and F light share a similar distribution such that both have high (low) values in shallow (deep) water regions. Our study demonstrates that light is a critical factor in regulating the phytoplankton growth in northern SFB, and a sediment transport model improves simulation of light availability in the water column.

54 ENVIRONMENTAL SCIENCES↗

Progress on Optimizing Wind Farms and Rotor Designs Using Adjoints

Modern wind plants are increasingly tasked with multiple performance objectives. In addition to designing plants that maximize power output and minimize the levelized cost of energy (LCOE), the design and operation of wind plants is increasingly influenced by challenges regarding grid integration of variable generation renewables. This places a growing emphasis on making wind plants more controllable and predictable. WindSE is a Reynolds-averaged Navier-Stokes (RANS) model designed around analytical gradient and adjoint methods, with the ability to capture terrain-induced effects, as shown in Figure 1. The recent addition of an unsteady solver with an actuator line method (ALM) and ongoing work to enable massively parallel optimizations gives it a unique niche to explore coupled plant-level controls and design problems. This code is an open source python package built on the FEniCS framework that utilizes fast, parallel PETSc solvers to model fluid flow throughout wind-farm scale domains. Two recent studies performed using WindSE demonstrate the capability to optimize under a wide variety of flow conditions and objective functions. In the first, we present an optimization focused on modifying the layout of a wind farm with a fixed number of turbines for maximum total power output [1]. This study highlights the ability to quickly perform simulations using the steady Navier-Stokes solver combined with rotors represented as actuator disks while also stressing the importance of capturing terrain-induced effects. Gradient-based optimization using the RANS equations is viable due to the inclusion of efficiently computed adjoint derivatives. We interpret the physical results of the optimal layout and also discuss the computational cost of scaling to larger problems. In the second study, we present the capabilities of the unsteady Navier-Stokes solver, where rotor-blade profiles represented by actuator lines are optimized to enhance wake steering effects and overall power production [2]. We quantify the wind plant performance gains obtained from this type of simultaneous control co-design optimization as compared to optimizing the blade design and yaw independently. Figure 2 shows the differences between a baseline two-turbine system and an optimized system where we fine-tune the blade chord profile. Results and challenges from each study are quickly summarized and used to motivate the current development efforts within WindSE. Current and future work is focused on enabling higher-resolution studies with more degrees of freedom through parallelization of both the simulation and optimization algorithms. We present benchmarking results to show that WindSE performs well in both weak- and strong-scaling tests and further demonstrate that the optimizer obtains the same convergence rates in both shared- and distributed-memory environments. Using larger wind farms, we can study deep-array effects within an optimization context, allowing the use of objective functions that have been previously unstudied. As an example, we present ongoing work on a blockage metric which characterizes the loss of available kinetic energy due to wake effects from multiple upstream turbines.

adjoint optimization↗

Well-to-wheels energy use and greenhouse gas emissions analysis of plug-in hybrid electric vehicles.

Researchers at Argonne National Laboratory expanded the Greenhouse gases, Regulated Emissions, and Energy use in Transportation (GREET) model and incorporated the fuel economy and electricity use of alternative fuel/vehicle systems simulated by the Powertrain System Analysis Toolkit (PSAT) to conduct a well-to-wheels (WTW) analysis of energy use and greenhouse gas (GHG) emissions of plug-in hybrid electric vehicles (PHEVs). The WTW results were separately calculated for the blended charge-depleting (CD) and charge-sustaining (CS) modes of PHEV operation and then combined by using a weighting factor that represented the CD vehicle-miles-traveled (VMT) share. As indicated by PSAT simulations of the CD operation, grid electricity accounted for a share of the vehicle's total energy use, ranging from 6% for a PHEV 10 to 24% for a PHEV 40, based on CD VMT shares of 23% and 63%, respectively. In addition to the PHEV's fuel economy and type of on-board fuel, the marginal electricity generation mix used to charge the vehicle impacted the WTW results, especially GHG emissions. Three North American Electric Reliability Corporation regions (4, 6, and 13) were selected for this analysis, because they encompassed large metropolitan areas (Illinois, New York, and California, respectively) and provided a significant variation of marginal generation mixes. The WTW results were also reported for the U.S. generation mix and renewable electricity to examine cases of average and clean mixes, respectively. For an all-electric range (AER) between 10 mi and 40 mi, PHEVs that employed petroleum fuels (gasoline and diesel), a blend of 85% ethanol and 15% gasoline (E85), and hydrogen were shown to offer a 40-60%, 70-90%, and more than 90% reduction in petroleum energy use and a 30-60%, 40-80%, and 10-100% reduction in GHG emissions, respectively, relative to an internal combustion engine vehicle that used gasoline. The spread of WTW GHG emissions among the different fuel production technologies and grid generation mixes was wider than the spread of petroleum energy use, mainly due to the diverse fuel production technologies and feedstock sources for the fuels considered in this analysis. The PHEVs offered reductions in petroleum energy use as compared with regular hybrid electric vehicles (HEVs). More petroleum energy savings were realized as the AER increased, except when the marginal grid mix was dominated by oil-fired power generation. Similarly, more GHG emissions reductions were realized at higher AERs, except when the marginal grid generation mix was dominated by oil or coal. Electricity from renewable sources realized the largest reductions in petroleum energy use and GHG emissions for all PHEVs as the AER increased. The PHEVs that employ biomass-based fuels (e.g., biomass-E85 and -hydrogen) may not realize GHG emissions benefits over regular HEVs if the marginal generation mix is dominated by fossil sources. Uncertainties are associated with the adopted PHEV fuel consumption and marginal generation mix simulation results, which impact the WTW results and require further research. More disaggregate marginal generation data within control areas (where the actual dispatching occurs) and an improved dispatch modeling are needed to accurately assess the impact of PHEV electrification. The market penetration of the PHEVs, their total electric load, and their role as complements rather than replacements of regular HEVs are also uncertain. The effects of the number of daily charges, the time of charging, and the charging capacity have not been evaluated in this study. A more robust analysis of the VMT share of the CD operation is also needed.

01 COAL, LIGNITE, AND PEAT↗

A Case Study about Energy and Cost Impacts for Different Community Scenarios Using a Community-Scale Building Energy Modeling Tool

The United States building sector consumed approximately 75% of electricity in 2019. By implementing renewable energy technologies and control strategies into buildings, future buildings will serve as energy generators as well as consumers. To accommodate this transition, communications among buildings and between buildings and the grid could provide more possibilities to optimize the energy performance of buildings. This paper develops a community-scale building energy model tool and conducts a case study adopting behind-the-meter distributed energy resources, sharing energy in different buildings, and using different electricity tariff structures. Three scenarios are studied: (1) electricity only supplied by the grid, (2) photovoltaic (PV) panels installed on and available to some but not all buildings, and (3) a connected community. To consider the impacts of locations and energy tariffs, this paper selects four cities and three electricity tariffs to evaluate the energy and cost performances of these three scenarios. The results show that the PV panels in Scenario 2 reduce 25% to 33% of the community-level electricity consumption and 20% to 30% of the community-level electricity cost compared with Scenario 1 in all studied locations and energy tariffs. By considering power management in the connected community (Scenario 3), the electricity consumption and cost can be further reduced by 6% to 7% and 5% to 11%, respectively, compared with Scenario 2.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Improving Area Control Error Diversity Interchange (ADI) Program by Incorporating Congestion Constraints

The area control error (ACE) determines how much a balancing authority (BA) needs to move its regulating units to meet mandatory control performance standard requirements. Regulation is an expensive resource that could cost several hundred million dollars a year for a BA. The amount of regulation needed in a system is increasing with more intermittent generation resources added to the system. The ACE diversity interchange (ADI) program provides a tool for reducing the regulation requirement by combining ACEs from several participating BAs followed by sharing the total ACE among all participating balancing areas. The effect is achieved as a result of the low statistical correlation between the original ACEs of participating BAs. A rule-based ADI approach has already been put into practice in the US Western Interconnection. The degree of actual ACE sharing is artificially limited because of the unknown redistribution of power flows and possible system congestion (these factors are not monitored in the existing ADI). This paper proposes a two-step linear programming (LP) ADI approach that incorporates congestion constraints. In the first step of the proposed LP ADI, the line transmission limits are enforced by setting up corresponding constraints. In the second step, the business fairness is pursued. Simulation is performed to compare the properties of the proposed LP ADI and the existing rule-based ADI. Favorable features, such as avoiding line limit violations and increasing the degree of possible ACE sharing, are observed for the proposed LP ADI.

99 GENERAL AND MISCELLANEOUS↗

An Evaluation of Representation Learning Methods in Particle Physics Foundation Models

We present a systematic evaluation of representation learning objectives for particle physics within a unified framework. Our study employs a shared transformer-based particle-cloud encoder with standardized preprocessing, matched sampling, and a consistent evaluation protocol on a jet classification dataset. We compare contrastive (supervised and self-supervised), masked particle modeling, and generative reconstruction objectives under a common training regimen. In addition, we introduce targeted supervised architectural modifications that achieve state-of-the-art performance on benchmark evaluations. This controlled comparison isolates the contributions of the learning objective, highlights their respective strengths and limitations, and provides reproducible baselines. We position this work as a reference point for the future development of foundation models in particle physics, enabling more transparent and robust progress across the community.

Chen, Michael [Caltech]↗