Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “sensor arrays”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 847 records · Page 47

Field Micrometeorological Measurements, Process-Level Studies and Modeling of Methane and Carbon Dioxide Fluxes in a Boreal Wetland Ecosystem

The main instrumentation platform consisted of eddy correlation sensors mounted on a scaffold tower at a height of 4.2 m above the peat surface. The sensors were attached to a boom assembly which could be rotated into the prevailing winds. The boom assembly was mounted on a movable sled which, when extended, allowed sensors to be up to 2 m away from the scaffolding structure to minimize flow distortion. When retracted, the sensors could easily be installed, serviced or rotated. An electronic level with linear actuators allowed the sensors to be remotely levelled once the sled was extended. Two instrument arrays were installed. A primary (fast-response) array consisted of a three-dimensional sonic anemometer, a methane sensor (tunable diode laser spectrometer), a carbon dioxide/water vapor sensor, a fine wire thermocouple and a backup one-dimensional sonic anemometer. The secondary array consisted of a one-dimensional sonic anemometer, a fine wire thermocouple and a Krypton hygrometer. Descriptions of these sensors may be found in other reports (e.g., Verma; Suyker and Verma). Slow-response sensors provided supporting measurements including mean air temperature and humidity, mean horizontal windspeed and direction, incoming and reflected solar radiation, net radiation, incoming and reflected photosynthetically active radiation (PAR), soil heat flux, peat temperature, water-table elevation and precipitation. A data acquisition system (consisting of an IBM compatible microcomputer, amplifiers and a 16 bit analog-to-digital converter), housed in a small trailer, was used to record the fast response signals. These signals were low-pass filtered (using 8-pole Butterworth active filters with a 12.5 Hz cutoff frequency) and sampled at 25 Hz. Slow-response signals were sampled every 5 s using a network of CR21X (Campbell Scientific, Inc., Logan Utah) data loggers installed in the fen. All signals were averaged over 30-minute periods (runs).

Verma, S. B.↗

Development of Fast, Background-Limited Transition-Edge Sensors for the Background-Limited Infrared/Sub-mm Spectrograph (BLISS) for SPICA

We report experimental progress toward demonstrating background-limited arrays of membrane-isolated transition-edge sensors (TESs) for the Background Limited Infrared/Sub-mm Spectrograph (BLISS). BLISS is a space-borne instrument with grating spectrometers for wavelengths lambda=35-435 micron and with R=lambda/delta lambda approximately equals 500. The goals for BLISS TESs are: noise equivalent power (NEP) = 5x10 (sup -20) W/Hz(exp 1/2) and response time tau <30ms. We expect background-limited performance from bilayers TESs with T(sub c) = 65mK and G=15fW/K. However, such TESs cannot be operated at 50mK unless stray power on the devices, or dark power P(sub D), is less than 200aW. We describe criteria for measuring P(sub D) that requires accurate knowledge of TC. Ultimately, we fabricated superconducting thermistors from Ir (T(sub c) >= 135mK) and Mo/Cu proximitized bilayers, where T(sub c) is the thermistor transition temperature. We measured the Ir TES arrays in our 50mK adiabatic demagnetization refrigerator test system, which can measure up to eight 1x32 arrays simultaneously using a time-division multiplexer, as well as our single-pixel test system which can measure down to 15mK. In our previous Ir array measurements our best reported performance was NEP=2.5x10(exp -19) W/Hz(sub 1/2) and Tau approximately equals 5ms for straight-beam TESs. In fact, we expected NEP approximately equals 1.5x10(exp -19)?W/Hz(sup 1/2) for meander beam TESs, but did not achieve this previously due to 1/f noise. Here, we detail improvements toward measuring the expected NEP and demonstrate NEP=(1.3+0.2)x10 (sup -19)W/Hz(exp 1/2) in our single-pixel test system and NEP=(1.6+/-0.3)x10(sup -19)W/Hz(sup 1/2) in our array test system.

infrared spectrometer↗

The MLA program at NASA

The Thematic Mapper (TM) on Landsat-D represents a significant improvement compared to the Multispectral Scanner (MSS) of the current Landsat satellites. However, there is a need for even higher spatial and spectral resolution. Such developments would, for instance, provide a significantly greater capability for mineral identification and the detection of vegetation stress. The pushbroom mode of imaging utilizing solid state linear or area arrays is widely regarded as the best approach to overcome the inherent limitations of a scanning type system. The Multispectral Linear Array (MLA) has become the generic term for the sensor concept and the technology associated with solid state electronically scanned arrays operating in the pushbroom mode. A brief review is provided of the MLA instrument concepts, associated technology developments, program status, and future plans.

Ando, K. J.↗

Multiabsorber Transition-Edge Sensors for X-Ray Astronomy

We are developing arrays of position-sensitive microcalorimeters for future x-ray astronomy applications. These position-sensitive devices commonly referred to as hydras consist of multiple x-ray absorbers, each with a different thermal coupling to a single-transition-edge sensor microcalorimeter. Their development is motivated by a desire to achieve very large pixel arrays with some modest compromise in performance. We report on the design, optimization, and first results from devices with small pitch pixels (<75 μm) being developed for a high-angular and energy resolution imaging spectrometer for Lynx. The Lynx x-ray space telescope is a flagship mission concept under study for the National Academy of Science 2020 decadal survey. Broadband full-width-half-maximum (FWHM) resolution measurements on a 9-pixel hydra have demonstrated ΔE(FWHM) = 2.23 ± 0.14 eV at Al-Kα, ΔE(FWHM) = 2.44 ± 0.29 eV at Mn-Kα, and ΔE(FWHM) = 3.39 ± 0.23 eV at Cu-Kα. Position discrimination is demonstrated to energies below <1 keV and the device performance is well-described by a finite-element model. Results from a prototype 20-pixel hydra with absorbers on a 50-μm pitch have shown ΔE(FWHM) = 3.38 ± 0.20 eV at Cr-Kα1. We are now optimizing designs specifically for Lynx and extending the number of absorbers up to 25/hydra. Numerical simulation suggests optimized designs could achieve ∼3 eV while being compatible with the bandwidth requirements of the state-of-the art multiplexed readout schemes, thus making a 100,000 pixel microcalorimeter instrument a realistic goal.

Smith, Stephen J.↗

Ambient Noise Attenuation Tomography Reveals an Asymmetric Damage Zone Across San Jacinto Fault Near Anza, California

Here, we perform seismic attenuation tomography of the shallow structure for the San Jacinto Fault in the Ramona Reservation of southern California. The study uses ambient seismic noise recorded by a linear array of 65 3-C sensors across the fault. We extract amplitude decay information, with uncertainty, from noise interferometry functions. To account for strong heterogeneities in the complex shallow fault zone structure, we apply a frequency-dependent amplitude correction for focusing/defocusing effects using inverted phase velocity maps obtained by solving the transport equation. We then estimate the attenuation structure based on the linear station-triplet method for both Love and Rayleigh waves. The attenuation tomography indicates strong attenuation correlated with known San Jacinto Fault surface traces. The Love wave attenuation tomography reveals an asymmetric damage zone that exists primarily on the fault side with faster seismic velocity, consistent with earthquake ruptures on a fault bimaterial interface with preferred propagation direction to the northwest.

58 GEOSCIENCES↗

Signal processing and spectral modeling for the BeEST experiment

The Beryllium Electron capture in Superconducting Tunnel junctions (BeEST) experiment searches for evidence of heavy neutrino mass eigenstates in the nuclear electron capture decay of 7 Be by precisely measuring the recoil energy of the 7 Li daughter. In Phase III, the BeEST experiment has been scaled from a singl superconducting tunnel junction (STJ) sensor to a 36-pixel array to increase sensitivity and mitigate gamma-induced backgrounds. Phase III also uses a new continuous data acquisition system that greatly increases the flexibility for signal processing and data cleaning. Here, we have developed procedures for signal processing and spectral fitting that are sufficiently robust to be automated for large datasets. Furthermore, this article presents the optimized procedures before unblinding the majority of the Phase III dataset to search for physics beyond the standard model.

6 ≤ A ≤ 19↗

Distributed Acoustic Sensing (DAS) on Opportunistic Networks_ A Feasibility Study Utilizing Fiber Optic Infrastructure at NEON Sites for DAS

This study demonstrates the feasibility of using Distributed Acoustic Sensing (DAS) on the opportunistic optical fiber infrastructure presented by NEON (National Ecological Observatory Network) sites. The test took place at the NEON Terrestrial Site designated D10 CPER. Unlit portions of the local fiber network were successfully spliced together and optimized for length and a Silixa iDAS sensor was installed. The resulting array (composed of 12 spliced fiber runs) totaled 875m in length. Over a period of 2 weeks, we gathered a high spatial and temporal resolution data set to characterize discernable signals and understand background noise. The data set was reviewed to extract wave signatures of identifiable origin, both anthropogenic and otherwise. Continent wide distribution of these sites makes them an interesting candidate for DAS and identifying measurable signal sources informs future DAS application on opportunistic fiber networks. These observations validate the utility of both the NEON and similarly small fiber networks (<1km) for geoscience, environmental, and security DAS applications and indicate possibilities for further inquiry in methods for DAS data collection and analysis.

42 ENGINEERING↗

Creating a Digital Twin for a Hydropower System through 3D Object Modeling: Alder Dam FY23

Hydropower stands as the world's leading source of renewable electricity, with hydropower plants spanning the globe. A typical hydropower plant comprises essential components including the governor, excitation system, generator, thrust bearing, hydraulic turbine, transformer, main lead, metering and control devices, tailwater depression system, and dissolved oxygen monitoring. Each of these components undergoes various measures and monitoring procedures. These measurements are collected through a diverse array of systems, encompassing standalone sensors, programmable logic controllers (PLCs), Supervisory Control and Data Acquisition (SCADA) systems, Internet of Things (IoT) devices, and data acquisition and integration platforms like OSI/PI.

13 HYDRO ENERGY↗

Hyperspectral x-ray imaging mapping capabilities for nuclear forensics

Nuclear forensics relies on the integration of complementary signatures to constrain the origins and history of materials. Outcomes benefit from the timeliness and precision of the disparate methods that form typical analysis chains. Sample forms are often either minute in quantity or contain signatures like morphology or composition heterogeneity encoded on a microscale, so many analysis techniques focus on resolving signatures on ever-smaller length scales. The new hyperspectral x-ray imaging (HXI) instrument developed at Los Alamos National Laboratory seeks to improve the information available from scanning electron microscopy (SEM) x-ray spectrum analysis through superior spectral energy resolution vs. typical energy dispersive spectroscopy (EDS) systems in common use in nuclear forensics and other microanalysis fields. Based on arrays of transition-edge sensor (TES) microcalorimeter detectors, this instrument achieves a typical energy resolution of 7 eV full-width at half-maximum (FWHM) at 2 keV, opening new possibilities in trace element detection/analysis and chemical state determination through spectral shape shifts. We present here some of the first applications of the HXI instrument to actinide samples and discuss potential maturation of this nascent technology for future analysis pipelines.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Historical Bolide Infrasound Dataset (1960–1972)

We present the first fully curated, publicly accessible archive of infrasonic records from ten large bolide events documented by the U.S. Air Force Technical Applications Center’s global microbarometer network between 1960 and 1972. Captured on analog strip-chart paper, these waveforms predate modern digital arrays and space-based sensors, making them a unique window on meteoroid activity in the mid-twentieth century. Prior studies drew important scientific conclusions from the records but released only limited artifacts, chiefly period–amplitude tables and unprocessed scans, leaving the underlying data inaccessible for independent study. The present release transforms those limited excerpts into a research-ready resource. By capturing ten large events in the mid-20th century, the dataset constitutes a critical reference point for assessing bolide activity before the advent of modern space-based and digital ground-based monitoring. The multi-year coverage and worldwide distribution of events provide a valuable reference for comparing past and more recent detections, facilitating assessments of long-term flux and the dynamics of acoustic wave propagation in Earth’s atmosphere. The dataset’s availability in a consolidated format ensures straightforward access to waveforms and derived measurements, supporting a wide range of scientific inquiries into bolide physics and infrasound monitoring. By preserving these historical acoustic observations, the collection maintains a significant record of mid-20th-century meteoroid entries. It thereby establishes a basis for further refinement of impact hazard evaluations, contributes to historical continuity in atmospheric observation, and enriches the study of meteoroid-generated infrasound signals on a global scale.

79 ASTRONOMY AND ASTROPHYSICS↗

A review of electron bombardment thruster systems/spacecraft field and particle interfaces

Information on the field and particle interfaces of electron bombardment ion thruster systems was summarized. Major areas discussed were the nonpropellant particles, neutral propellant, ion beam, low energy plasma, and fields. Spacecraft functions and subsystems reviewed were solar arrays, thermal control systems, optical sensors, communications, science, structures and materials, and potential control.

Byers, D. C.↗

A review of electron bombardment thruster systems/spacecraft field and particle interfaces

This paper collates and summarizes information on the field and particle interfaces of electron bombardment ion thruster systems. Major areas discussed are the nonpropellant particles, neutral propellant, ion beam, low energy plasma, and fields. Spacecraft functions and subsystems reviewed are solar arrays, thermal control systems, optical sensors, communications, science, structures and materials, and potential control. An appendix is included to facilitate identification of specific interaction areas.

Byers, D. C.↗

Rationale for an experimental test for flexible space structure attitude control

The problems of large flexible spacecraft control are characterized by the infinite bandwidth of structural vibrations, which cannot be accounted for in the dynamic design model. This may lead to instability even, if ideal control hardware is assumed, which can be concluded from preceding numerical investigations. Additional performance limitations are expected to occur due to hardware constraints. A laboratory experiment is proposed to investigate the key problems in more detail. The test setup requirements being defined by the idealized control system are extremely high demanding a high speed processor and special hardware component developments. The test element is a wire suspended plate being controlled by an array processor via high performance sensors and actuators. First tests on component level indicate the feasibility of the system presently being developed.

Lange, T.↗

Visible and shortwave infrared focal planes for remote sensing instruments

The development of solid-state sensor technology for multispectral linear array (MLA) instruments is described. A buttable four-spectral-band linear-format CCD and a buttable two-spectral band linear-format short-wave IR CCD have been designed, and first samples have been demonstrated. In addition, first-sample four-band interference filters have been fabricated, and hybrid packaging technology is being developed. Based on this development work, the design and construction of focal planes for a Shuttle sortie MLA instrument have begun. This work involves a visible and near-IR focal plane with 2048 pixels x 4 spectral bands and a short-wave IR focal plane with 1024 pixels x 2 spectral bands.

Tower, J. R.↗

Recycling isotachophoresis - A novel approach to preparative protein fractionation

The concept of automated recycling isotachophoresis (RITP) as a purification methodology is discussed, in addition to a description of the apparatus. In the present automated RITP, the computer system follows the achievement of steady state using arrays of universal and specific sensors, monitors the position of the front edge of the zone structure, activates the counterflow if the leading boundary passes a specified position along the separation axis, or changes the applied current, accordingly. The system demonstrates high resolution, in addition to higher processing rates than are possible in zone electrophoresis or isoelectric focusing.

Sloan, Jeffrey E.↗

Surface temperature measurements using a thin film thermal array

A thin film device was designed and fabricated to measure surface temperatures. An array of eight integrated thermal sensors are mounted on a 0.002 inch (0.05 mm) Kapton film and multiplexed to obtain an area thermal measurement. The device was tested on a flat plate airfoil and demonstrated a temperature variation of 0.55 C maximum and 0.05 C minimum compared to embedded thermocouples. Future improvements are also discussed.

Dillon-Townes, L. A.↗

Earth Science Geostationary Platform Technology

The objective of the workshop was to address problems in science and in four technology areas (large space antenna technology, microwave sensor technology, electromagnetics-phased array adaptive systems technology, and optical metrology technology) related to Earth Science Geostationary Platform missions.

Wright, Robert L.↗