Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “sensitivity study”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 847 records · Page 47

TU-C-BRE-08: IMRT QA: Selecting Meaningful Gamma Criteria Based On Error Detection Sensitivity

Purpose: To develop a strategy for defining meaningful tolerance limits and studying the sensitivity of IMRT QA gamma criteria by inducing known errors in QA plans. Methods: IMRT QA measurements (ArcCHECK, Sun Nuclear) were compared to QA plan calculations with induced errors. Many (>24) gamma comparisons between data and calculations were performed for each of several kinds of cases and classes of induced error types with varying magnitudes (e.g. MU errors ranging from -10% to +10%), resulting in over 3,000 comparisons. Gamma passing rates for each error class and case were graphed against error magnitude to create error curves in order to represent the range of missed errors in routine IMRT QA using various gamma criteria. Results: This study demonstrates that random, case-specific, and systematic errors can be detected by the error curve analysis. Depending on location of the peak of the error curve (e.g., not centered about zero), 3%/3mm threshold=10% criteria may miss MU errors of up to 10% and random MLC errors of up to 5 mm. Additionally, using larger dose thresholds for specific devices may increase error sensitivity (for the same X%/Ymm criteria) by up to a factor of two. This analysis will allow clinics to select more meaningful gamma criteria based on QA device, treatment techniques, and acceptable error tolerances. Conclusion: We propose a strategy for selecting gamma parameters based on the sensitivity of gamma criteria and individual QA devices to induced calculation errors in QA plans. Our data suggest large errors may be missed using conventional gamma criteria and that using stricter criteria with an increased dose threshold may reduce the range of missed errors. This approach allows quantification of gamma criteria sensitivity and is straightforward to apply to other combinations of devices and treatment techniques.

60 APPLIED LIFE SCIENCES↗

Magnetic, dielectric, magnetoelectric, and microstructural studies demonstrating improved magnetoelectric sensitivity in three-phase BaTiO{sub 3}-CoFe{sub 2}O{sub 4}-poly(vinylidene-fluoride) composite

A three-phase BaTiO{sub 3}-CoFe{sub 2}O{sub 4}-poly(vinylidene-fluoride) (BT-CF-PVDF) particulate composite showing a maximum magnetoelectric voltage coefficient alpha{sub E33}approx26 mV/cm Oe, at a small applied magnetic field H{sub DC}=263 Oe, has been demonstrated in this work. Large magnetoelectric response in this composite (particulate BT-CF embedded in PVDF matrix) is possibly a result of the effective mechanical interaction between CF and BT through the PVDF matrix. Processing temperatures for composite preparation are low, ensuring no chemical reaction or interdiffusion between the atoms of piezoelectric and magnetostrictive phases, leading to large value of magnetoelectric voltage coefficient. Detailed measurements of dielectric, magnetic, and static magnetoelectric data are reported. Peak in the dielectric spectrum is shown to correlate with the buildup of magnetization in the composite. Although the M-H loop gives M{sub s}, M{sub r}, and H{sub c} (=37.2 emu/g, 16.4 emu/g, and 830 Oe, respectively) in accordance with the expected values (wt % of CF in the composite is 52.5%), the overall magnetic behavior of the composite is identified as 'spin glass'.

36 MATERIALS SCIENCE↗

Modeling the Residual Stresses in Reactive Resins-Based Materials: a Case Study of Photo-Sensitive Composites for Dental Applications

Residual stresses in reactive resins-based composites are associated to the net volumetric contraction (shrinkage) arising during the cross-linking reactions. Depending on the restoration geometry (the ratio of the free surface area to the volume of the cavity) the frozen-in stresses can be as high as the strength of the dental composites. This is the main reason why the effectiveness and then the durability of restorations with composites remains quite lower than those realized with metal alloys based materials. In this paper we first explore the possibility to circumvent the mathematical complexity arising from the determination of residual stresses in reactive systems three-dimensionally constrained. Then, the results of our modeling approach are applied to a series of commercially available composites showing that almost all samples develop residual stresses such that the restoration undergoes failure as soon as it is realized.

36 MATERIALS SCIENCE↗

High-Sensitivity Nuclear-Structure Studies of Rare Isotopes and Few-Electron Systems

This final technical report presents the work that was completed during the award period for DE-SC0017649 related to the structure of nuclei for both astrophysics and tests of the Standard Model, namely: Using trapped bare (and few-electron) radioactive ions to probe the nature of elec- troweak decay modes under extreme conditions for structure and astrophysics, Providing experimental nuclear structure guidance to nuclear theory in systems relevant for testing the Standard Model, and Working with the HPGe sub-group of the FRIB decay station collaboration, which includes the technical development of a next-generation γ-ray spectrometer.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Quantifying the Resolution Sensitivity of the Kain–Fritsch Scheme Across the Gray Zone by Isolating Interactions: A TWP‐ICE Case Study

The resolution sensitivity of the Kain–Fritsch (KF) convection scheme and the role of interactions between the physics and dynamics within the gray zone (<10 km) were investigated using the Separate Physics and Dynamics Experiment (SPADE) framework. Two groups of experiments were conducted using the Weather Research and Forecasting (WRF) model via traditional (Tradition) runs and SPADE runs with resolutions of 1, 2, 4, and 8 km during the wet period of the Tropical Warm Pool–International Cloud Experiment (TWP‐ICE). Results show that the KF scheme simulates the weakened convective processes well as the resolution increases in both groups, and the changes in the convective variables with resolution in SPADE are smaller than in the Tradition group. This indicates the important effects of interactions between model components on convection parameterizations as the resolution changes. Additionally, the microphysics variables remain nearly unchanged with resolution in SPADE and weaken slightly in Tradition as the resolution decreases, suggesting the relatively weaker influences of model interactions for the resolved‐cloud parameterization. Therefore, the scale‐aware behavior of KF scheme is further strengthened in Tradition runs, primarily through inhibiting the strength of stratiform processes through physics–dynamics interactions and physical components.

54 ENVIRONMENTAL SCIENCES↗

An isotope identification injection study with GammaTracker

GammaTracker is a portable handheld radioisotope identifier using position sensitive CdZnTe detectors. High confidence isotope identification is possible on GammaTracker owing to the system's relatively high energy resolution and count rate sensitivity. A study was undertaken to evaluate the isotope identification performance of a prototype unit. Background and source spectra for various nuclides were measured and then randomly sampled to simulate various integration times and source intensities. The resulting spectral data sets were then run through the isotope identification algorithm to determine the probability of detection and the false alarm rate for each nuclide. The process was repeated for various isotope identification input parameters until an optimized set was achieved. This paper presents results from the injection study.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Accuracy and Usefulness of Select Methods for Assessing Complete Collection of 24‐Hour Urine: A Systematic Review

Twenty‐four–hour urine collection is the recommended method for estimating sodium intake. To investigate the strengths and limitations of methods used to assess completion of 24‐hour urine collection, the authors systematically reviewed the literature on the accuracy and usefulness of methods vs para‐aminobenzoic acid ( PABA ) recovery (referent). The percentage of incomplete collections, based on PABA , was 6% to 47% (n=8 studies). The sensitivity and specificity for identifying incomplete collection using creatinine criteria (n=4 studies) was 6% to 63% and 57% to 99.7%, respectively. The most sensitive method for removing incomplete collections was a creatinine index <0.7. In pooled analysis (≥2 studies), mean urine creatinine excretion and volume were higher among participants with complete collection ( P <.05); whereas, self‐reported collection time did not differ by completion status. Compared with participants with incomplete collection, mean 24‐hour sodium excretion was 19.6 mmol higher (n=1781 specimens, 5 studies) in patients with complete collection. Sodium excretion may be underestimated by inclusion of incomplete 24‐hour urine collections. None of the current approaches reliably assess completion of 24‐hour urine collection.

John, Katherine A.↗

Flow boiling transient critical heat flux tests with stainless steel and FeCrAl: Transient correlation implementation, model calibration, and sensitivity analysis

In this study, steady-state and transient internal-flow critical heat flux (CHF) experiments were carried out under two flow conditions, at atmospheric pressure, on 316 stainless steel (316-SS) and iron-chromium-aluminum (FeCrAl) tubes. Slow power transients at a low mass flow (300 kg/m 2 - s) with very low subcooling (X e =-0.0054) generated premature CHFs, which were prevented by faster power transients and high mass flow (1000 kg/m 2 - s). The measured transient CHFs increased linearly with increasing power transients, compared with the steady-state CHF. Yet, the wall superheat at the CHFs decreased with faster power transients. Transient CHF correlations highlighting heterogeneous spontaneous nucleation were calibrated to the measured CHFs and compared with other existing correlations. Transient CHF multipliers were acquired from pool and flow boiling empirical CHF correlations that were generated. The multipliers were applied to the RELAP5-3D nuclear system code to analyze the discrepancies between the measured data and the predicted CHF and post-CHF behavior, which improved peak cladding temperature predictions by 24.6%. A variance-based global sensitivity study perturbing the experimental uncertainties and cladding material thermal properties showed the diminishing influence of flow boiling heat transfer with increasing power transients, highlighting the significance of the volumetric heat capacity for the cladding integrity during transients. Transient CHF correlations were applied to the most limiting design basis accident: a hot-zero-power reactivity-initiated accident on a generic pressurized water reactor RELAP5-3D model.

36 MATERIALS SCIENCE↗

Sensitivity of CUORE to Neutrinoless Double-Beta Decay

In this paper, we study the sensitivity of CUORE, a bolometric double-beta decay experiment under construction at the Laboratori Nazionali del Gran Sasso in Italy. Two approaches to the computation of experimental sensitivity are discussed and compared, and the formulas and parameters used in the sensitivity estimates are provided. Assuming a background rate of 10{sup -2} cts/(keV kg y), we find that, after 5 years of live time, CUORE will have a 1 {sigma} sensitivity to the neutrinoless double-beta decay half-life of {caret T{sup 0{nu}}{sub 1/2}}(1{sigma} ) = 1.6x 10{sup 26} y and thus a potential to probe the effective Majorana neutrino mass down to 41-95 meV; the sensitivity at 1.64{sigma} , which corresponds to 90% C.L., will be {caret T{sup 0{nu}}{sub 1/2}(1.64{sigma} }) = 9.5x10{sup 25} y. This range is compared with the claim of observation of neutrinoless double-beta decay in {sup 76}Ge and the preferred range in the neutrino mass parameter space from oscillation results.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Experimental and theoretical studies of the characteristics of position-sensitive photodetectors based on n-CdSe/mica epitaxial layers

The experimental results of studying the output characteristics of four-contact semiconductor position-sensitive photodetectors fabricated on the basis of photosensitive n-CdSe/mica epitaxial layers are presented. The position sensitivity of layers was theoretically analyzed based on elementary current flow theory and the electric dipole model. It is found that the theoretical characteristics of the coordinate sensitivity of the studied position-sensitive photodetectors correlate with the experimental dependences in terms of both curve shape and positions of the maxima. The results of determining the specific spectral sensitivity indicate the prospects for n-CdSe layers as position-sensitive photodetectors.

36 MATERIALS SCIENCE↗

Planck intermediate results: XL. The Sunyaev-Zeldovich signal from the Virgo cluster

The Virgo cluster is the largest Sunyaev-Zeldovich (SZ) source in the sky, both in terms of angular size and total integrated flux. Planck’s wide angular scale and frequency coverage, together with its high sensitivity, enable a detailed study of this big object through the SZ effect. Virgo is well resolved by Planck, showing an elongated structure that correlates well with the morphology observed from X-rays, but extends beyond the observed X-ray signal. We find good agreement between the SZ signal (or Compton parameter, y c ) observed by Planck and the expected signal inferred from X-ray observations and simple analytical models. Owing to its proximity to us, the gas beyond the virial radius in Virgo can be studied with unprecedented sensitivity by integrating the SZ signal over tens of square degrees. In this paper, we study the signal in the outskirts of Virgo and compare it with analytical models and a constrained simulation of the environment of Virgo. Planck data suggest that significant amounts of low-density plasma surround Virgo, out to twice the virial radius. We find the SZ signal in the outskirts of Virgo to be consistent with a simple model that extrapolates the inferred pressure at lower radii, while assuming that the temperature stays in the keV range beyond the virial radius. The observed signal is also consistent with simulations and points to a shallow pressure profile in the outskirts of the cluster. This reservoir of gas at large radii can be linked with the hottest phase of the elusivewarm/hot intergalactic medium. Taking the lack of symmetry of Virgo into account, we find that a prolate model is favoured by the combination of SZ and X-ray data, in agreement with predictions. In conclusion, based on the combination of the same SZ and X-ray data, we constrain the total amount of gas in Virgo. Under the hypothesis that the abundance of baryons in Virgo is representative of the cosmic average, we also infer a distance for Virgo of approximately 18 Mpc, in good agreement with previous estimates.

79 ASTRONOMY AND ASTROPHYSICS↗

Effect of pulsed hollow electron-lens operation on the proton beam core in LHC

Collimation with hollow electron beams is currently one of the most promising concepts for active halo control in the HL-LHC. In order to further increase the diffusion rates for a fast halo removal as e.g. desired before the squeeze, the electron lens (e-lens) can be operated in pulsed mode. In case of profile imperfections in the electron beam the pulsing of the e-lens induces noise on the proton beam which can, depending on the frequency content and strength, lead to emittance growth. In order to study the sensitivity to the pulsing pattern and the amplitude, a beam study (machine development MD) at the LHC has been proposed for August 2016 and we present in this note the preparatory simulations and estimates.

43 PARTICLE ACCELERATORS↗

Numerical Modeling of the Sensitivity of X-Ray Driven Implosions to Low-Mode Flux Asymmetries

In this study, the sensitivity of inertial confinement fusion implosions of the type performed on the National Ignition Facility (NIF) [1] to low-mode flux asymmetries has been investigated numerically. It is shown that large-amplitude, low-order mode shapes (Legendre polynomial P4), resulting from associated low order flux asymmetries, cause spatial variations in capsule and fuel momentum that prevent the DT “ice” layer from being decelerated uniformly by the hot spot pressure. This reduces the transfer of kinetic to internal energy of the central hot spot, thus reducing neutron yield. Furthermore, synthetic gated x-ray images indicate that the P4 component of hot spot self-emission shape is insensitive to P4 hot spot shapes, and a positive P4 asymmetry aliases itself as a negative or oblate P2 in these images. Correction of this apparent P2 distortion can further distort the implosion while creating a round x-ray image. Long wavelength asymmetries may be playing a significant role in the observed yield reduction of NIF DT implosions relative to detailed post-shot 2D simulations.

42 ENGINEERING↗

Sensitivity analysis for dose deposition in radiotherapy via a Fokker–Planck model

In this paper, we study the sensitivities of electron dose calculations with respect to stopping power and transport coefficients. We focus on the application to radiotherapy simulations. We use a Fokker–Planck approximation to the Boltzmann transport equation. Equations for the sensitivities are derived by the adjoint method. The Fokker–Planck equation and its adjoint are solved numerically in slab geometry using the spherical harmonics expansion (P N ) and an Harten-Lax-van Leer finite volume method. Our method is verified by comparison to finite difference approximations of the sensitivities. Finally, we present numerical results of the sensitivities for the normalized average dose deposition depth with respect to the stopping power and the transport coefficients, demonstrating the increase in relative sensitivities as beam energy decreases. In conclusion, this in turn gives estimates on the uncertainty in the normalized average deposition depth, which we present.

59 BASIC BIOLOGICAL SCIENCES↗

Sensitivity analysis of a geometric calibration method using projection matrices for digital tomosynthesis systems

Purpose: To study the sensitivity of a geometric calibration method using projection matrices for digital tomosynthesis systems. Methods: A generic geometric calibration method for tomographic imaging systems has been presented in our previous work. The method involves a scan of a calibration phantom with multiple markers. Their locations in projection images are detected and are associated with their 3D coordinates to compute 3x4 projection matrices, which can be used in subsequent image reconstruction. The accuracy of geometric calibration may be affected by errors in the input data of marker positions. The effects of errors may depend on the number of markers and the volume surrounded by them in 3D space. This work analyzed the sensitivity of the calibration method to the above factors. A 6 cm CIRS breast research phantom and a prototype breast tomosynthesis system were used for our tests. A high contrast ring and two small speck groups were reconstructed in various testing cases for comparison. To achieve quantitative assessment, a 15x15 point detection mask was adopted for detecting signals and for computing changes between testing cases and the regular geometric calibration. Results: When 3D coordinates and 2D projections of markers were accurate, all tested numbers of markers, 6-44, provided similar high quality reconstructions of the ring and the two speck groups. Errors in marker positions resulted in image degradations and signal changes, which increased with fewer markers and smaller volume surrounded by markers in the 3D object space. Signal changes of small specks were more significant than those of the ring. Errors in marker projections produced drastic image degradations. Coplanar marker placement caused a failure in projection matrix computation. Conclusions: For practical geometric calibration phantom design, ample markers are desired. They need to have a large volumetric coverage in the 3D space and be far from being coplanar. Precise determination of marker projections on detector planes is crucial for accurate geometric calibration and for small object detection using the reconstructed images.

60 APPLIED LIFE SCIENCES↗

A non-linear k-{epsilon} turbulent model sensitivity analysis for flow across a PWR spacer grid with mixing vanes

In this work we studied the sensitivity of different computational fluid dynamics (CFD) numerical solutions on turbulence model, domain discretization mesh type, and inlet boundary conditions. The case under examination is a turbulent one-phase flow (water) through a scaled nuclear pressurized water reactor (PWR) fuel assembly. The main feature of this geometrical configuration is the presence of a spacer grid with mixing vanes. The design of a spacer grid with mixing vanes plays a key role for the core heat transfer efficiency, increasing the coolant heat transfer coefficient. The main reason for this is the introduction of the top mixing vanes, which consist of an ordered repetitive succession of wings that generate secondary swirling flows. The increase of heat transfer efficiency also increases the critical heat flux (CHF), making it possible to increase the design and operational limits, far from boiling crises (departure of nucleate boiling in case of a PWR). The main focus of this work was to analyze the simulation capabilities of Reynolds-averaged Navier-Stokes (RANS) models (a cubic non-linear k-epsilon model formulation) for this complex flow geometry. The CFD code used was CD-Adapco STAR-CCM+.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗