Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “scintillator”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 847 records · Page 47

CLARION2-TRINITY: A Compton-suppressed HPGe and GAGG:Ce-Si-Si array for absolute cross-section measurements with heavy ions

The design and performance of a new Compton-suppressed HPGe and charged-particle array, CLARION2-TRINITY, are described. The TRINITY charged-particle array is comprised of 64 Cerium-doped Gadolinium Aluminum Gallium Garnet (GAGG:Ce) crystals configured into five rings spanning 7–54 degrees, and two annular silicon detectors that can shadow or extend the angular coverage to backward angles with minimal $\gamma$-ray attenuation. GAGG:Ce is a non-hygroscopic, bright, and relatively fast scintillator with a light distribution well matched to SiPMs. Count rates up to 40 kHz per crystal are sustainable. Fundamental characteristics of GAGG:Ce are measured and presented, including light- and heavy-ion particle identification (PID) capability, pulse-height defects, radiation hardness, and emission spectra. The CLARION2 array consists of up to 16 Compton-suppressed HPGe Clover detectors (efficiency at 1 MeV) configured into four rings (eight HPGe crystal rings) using a non-Archimedean geometry that suppresses back-to-back coincident 511-keV gamma rays. The entire array is instrumented with 100- and 500-MHz (14 bit) waveform digitizers which enable triggerless operation, pulse-shape discrimination, fast timing, and pileup correction. Lastly, two examples of experimental data taken during the commissioning of the CLARION2-TRINITY system are given: a PID spectrum from 16 O + 18 O fusion-evaporation, and PID and Doppler-corrected -ray spectra from 48 Ti + 12 C Coulomb excitation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Advancements of the nSpec system

For this study, a new characterization of the detector response for the EJ301 liquid scintillator based nSpec system has been conducted at the Los Alamos Neutron Science Center. The new characterization was accomplished in two orders of magnitude less time and with better statistics than the previous characterization. The new and old characterization methods were compared by conducting both types of characterization on two detectors (one EJ301 and one EJ301D). The two methods show consistent results and compare well to results previously published in the literature; however, the results from the characterization of the original nSpec detector show discrepancies that have been identified as being caused by oxygen being absorbed into the detector due to a leak. The new characterized detector response shows improved spectrum unfolding performance than the previous characterization. The cross talk of the detector system was also characterized as a function of incident neutron energy and found to have a negligible impact on spectrum unfolding results. Alternative materials (EJ301D and stilbene) were also characterized in a first step towards an upgraded system. The different materials show little difference in unfolding performance, but the comparison is ongoing. A SiPM based stilbene detector was used to evaluate the use of SiPMs in a future system upgrade. The SiPM provides adequate performance, but the custom SiPM readout results in a much longer pulse width than PMT based systems. The measured light output of the SiPM based stilbene compares well with the results in literature. Future work will look at additional materials (deuterated stilbene and organic glass) and optimizing the SiPM readout to decrease the pulse width.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Systematic evaluation of fast neutron sensing with Cesium Hafnium Chloride

Cesium Hafnium Chloride (CHC) is a promising new scintillator for dual mode sensing of both neutrons and gamma-rays. The high chlorine content allows for both 35 Cl(n,p) 35 S and 35 Cl(n,α) 32 P reaction channels leading to reliable detection of fast neutrons. By utilizing pulse shape discrimination (PSD), these neutron interactions may be reliably separated from gamma-ray signals with a high figure-of-merit (FOM) after optimization of the PSD algorithm. Here, in this study, the PSD algorithm settings for CHC were systematically investigated using a bare 252 Cf and a lead shielded plutonium beryllium neutron source. It was found that the PSD algorithm settings affects both the FOM and the neutron detection efficiency, but a FOM as high as 4.5 for alpha particles was observed in one data processing scenario. Further, an intrinsic 5 parts per million alpha emitting contamination was observed in the sample, which we attribute to natural uranium.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Determination of energy-dependent neutron backgrounds using shadow bars

Understanding the neutron background is essential for determining the neutron yield from nuclear reactions. Here, the neutron backgrounds were determined for heavy-ion collision experiment using the shadow-bar method, where beams of 40,48 Ca at 56, 140 MeV/u impinged on targets of 58,64 Ni and 112,124 Sn. In the analysis presented here, brass shadow bars are placed in front of organic liquid scintillator neutron detectors to determine the energy-dependent neutron background fractions. The measurement of neutron spectra with and without shadow bars is important to determine the neutron background more accurately. The neutron background, along with its sources and systematic uncertainties, are explored with a focus on the impact of background models and their dependence on neutron energy.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Development of a compact fast-neutron spectrometer for nuclear emergency response applications

We have developed a Compact Fast Neutron Spectrometer (CFNS) for passive assay of special nuclear material (SNM) through the observation of fast neutrons. The CFNS consists of eight organic glass scintillators (OGS) coupled to silicon photomultipliers and a waveform digitizer, which are integrated within a human-portable box. The CFNS determines the neutron energy profile by spectrum unfolding using the Maximum-Likelihood Expectation Maximization method. The detector acquisition system was optimized to have a dynamic range of up to 10 MeV neutron energy. Bulk special nuclear material (SNM) measurements from the National Criticality Experiments Research Center were analyzed for SNM validation/examination. Additionally, the results show that the CFNS can be used to distinguish between fission and (α, n) neutron emitters, regardless of intervening material type (Cu and polyethylene) and thickness, by taking the ratio of neutron counts at different regions in the unfolded energy spectrum. Additionally, by fitting an exponential curve to the unfolded energy spectrum of PuO 2 and Pu neutron emitters, the CFNS showed the ability of distinguishing between pure Pu oxide, pure Pu metal and mixed oxide-metal configurations.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Sub-millimeter resolution SiPM-based neutron anger camera

Thermal and cold neutron beamlines require detector systems that have a high neutron efficiency, large active area, and good spatial resolution. One type of detector that has been implemented at beamlines at the Spallation Neutron Source (SNS) is a scintillator-based Anger camera that utilizes photomultiplier tubes (PMTs) as photodetectors. In this work, we present a new Anger camera design that replaces PMTs with silicon photomultipliers (SiPMs). This new design offers better resolution, less distortion, and more compactness than the previous cameras. A camera with active area of ~100 cm 2 was shown to have a spatial resolution better than 0.5 mm. Additionally, the use of SiPMs allows for use in strong magnetic fields, opening the possibility of additional experimental capabilities. In conclusion, prototype has been built that demonstrates vacuum-compatibility, as required for a proposed beamline for the Second Target Station at SNS.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Quantification of the light output anistropy in deuterated stilbene

Deuterated stilbene is an organic scintillator that is a desirable material for fast neutron spectroscopy using spectrum unfolding techniques without requiring time-of-flight information. Due to the crystal structure of the material, some anisotropy of the light output exists, which is dependent on the direction of heavy charged particle recoil relative to the crystal structure. The anisotropy of trans-stilbene (hereafter referred to as stilbene) has been well characterized in previous work, but for deuterated stilbene, the anisotropy has only been partially characterized along the a and b crystal axes, while the artificial c' axis, which shows the largest anisotropy in stilbene, has not been characterized until this publication. Here, in this work, two deuterated stilbene crystals were characterized with neutron energies up to 35 MeV at the Los Alamos Neutron Science Center. For one of the crystals, the response is characterized along the a, b, and c' axes. This characterization shows a distinct anisotropy along the axes in deuterated stilbene, which is very similar to that found in regular stilbene, such that the a axis is the brightest, while the b' and c' axes are approximately 3% and 20%–35% lower relative to the a axis.

36 MATERIALS SCIENCE↗

Evaluation of the performance of event reconstruction algorithms in the JSNS 2 experiment using a 252 Cf calibration source

JSNS 2 investigates short-baseline neutrino oscillations using a 24-meter baseline and a 17-tonne Gd-loaded liquid scintillator target. Accurate event-reconstruction algorithms are crucial for analyzing experimental data. The algorithms undergo meticulous validation through calibration with a 252 Cf source. This paper outlines the methodology and evaluates the reconstruction performance, focusing on neutrino interactions up to approximately 50 MeV for sterile neutrino searches. Both 252 Cf and Michel electron events are studied to evaluate reconstruction accuracy. The analysis concludes that the uncertainty of the fiducial volume, with an appropriate correction, is much less than the requirement of JSNS 2 requirement (10%). Furthermore, the energy resolution is measured to be 3.3 ± 0.1% for the Michel electron endpoint and 4.3 ± 0.1% for the n-Gd peak in the central region.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Thermal neutron imaging detector with wavelength shifting fiber and digital readout

Here, we developed a large area, digital thermal neutron imaging detector. The detector uses a 6 LiF/ZnS(Ag) neutron-sensitive scintillator combined with wavelength shifting fiber technology. The signals from fiber channels are amplified, integrated, and digitized using individual analog-to-digital converters for each channel. The neutron position is determined from the digitized signal using a least-squares gaussian-fitting algorithm. The detector size was 77 × 38 cm 2 (2926 cm 2 ), it provided 1.3 mm resolution, and its resolution can further be improved. The detector was designed for a powder diffraction neutron scattering beamline and provided substantial improvement of d-space resolution compared with existing detectors. This detector may have broader applications due to its large area and high spatial resolution extended over its large area.

6LiF/ZnS(Ag) scintillator↗

Multiple Coulomb scattering in acrylic of a 221.3 MeV therapeutic proton beam

Measurements of multiple Coulomb scattering (MCS) distributions for 221.3 MeV therapeutic protons are presented using a novel detector system comprised of a thin scintillator, a pellicle mirror, and a digital camera. The MCS distributions were characterized for three acrylic phantoms of varying lengths and for two biological density-equivalent phantoms simulating bone and muscle. Additionally, beam profiles were measured across an energy range of 80.3–221.3 MeV in 20 MeV increments. The observed energy dependence of the photon yields is consistent with the tabulated stopping power values. Finally, the experimental results are benchmarked against Geant4 simulations, demonstrating consistent agreement and validating the capability of the detector system for radiology measurements.

Digital camera↗

Evaluating Brightness and Stability of Cathodoluminescence from Colloidal Semiconductor Nanocrystals

Cathodoluminescence offers promise as a technique for correlation of atomic structure with electronic structure at the level of individual nanoparticles or even defects, with the ability to analyze complex nanostructures at length-scales far below those typically available to optical spectroscopy. Unlike other forms of electron microscopy, cathodoluminescence offers direct insights into the electronic structure of the visualized sample. Despite reports more than 10 years ago of individual nanoparticle cathodoluminescence, effective cathodoluminescence collection from colloidal semiconductor materials is relatively rare and remains challenging due to the instability of materials under the conditions of electron beam irradiation. In this work, to clarify the roadblocks for cathodoluminescence analysis of colloidal nanocrystals, we attempt a comprehensive study of the cathodoluminescence properties of semiconductor quantum shells, which have a thin concentric CdSe shell surrounding CdS nanoparticles, then surrounded by a further concentric CdS shell. These same materials were recently demonstrated to show promising scintillation performance in radioluminescence measurements, including high brightness (up to 100 ph/keV) and excellent durability. Comparative quantum yield measurements are designed to assess the brightness of semiconductor nanocrystal films, which show that the quantum shells are much less bright under electron irradiation compared to X-ray photons. Instability of CL emission is assigned to charging effects on the samples—and not thermal effects—through a series of voltage, current, dwell time, and atmospheric pressure experiments.

cathodoluminescence↗

Effects of Quantum Dot Loading on the Radioluminescence Efficiency in Quantum-Dot-Embedded Composites

Nanoparticle-embedded plastic scintillators are an emerging technology for fast, large-area, high-resolution radiation detection and imaging. Here, this study investigates the properties of such composites, focusing on the effects of the quantum dot (QD) concentration on the radioluminescence (RL) intensity, spectra, and dynamics. Experiments using CdSe/CdS QDs in a polymer reveal a superlinear increase in RL with the QD concentration despite optical losses from inner filtering and interparticle interactions. When corrected for inner filtering, RL shows a quadratic concentration dependence, consistent with simple analytical models of improving the secondary electron capture. Practically, the benefits of high QD concentrations are muted by optical losses, but the findings apply to other systems with insulating hosts. In addition to manipulating emission for large effective Stokes shifts, future improvements may come from hosts with higher stopping power and better charge transport, which enable more effective funneling of excitations but without concomitant optical losses associated with high nanoparticle concentrations.

Auger recombination↗

The Path to Enlightenment: Progress and Opportunities in High Efficiency Halide Perovskite Light-Emitting Devices

Besides the flourishment in photovoltaics, halide perovskites hold great promise to compete with leading contenders among solution-processed emitters, such as organics and semiconductor colloidal nanocrystals, in the field of light emission. Halide perovskites exhibit outstanding optoelectronic properties, including high photoluminescence quantum yields, facile bandgap tunability, narrow emission line widths, and respectable carrier mobilities, promoting them to thrive in versatile light-emitting applications such as light-emitting diodes, lasers, X-ray scintillators, and circularly polarized light sources. Herein, we discuss the underlying physics of light emission in state-of-the-art perovskite light-emitting devices and focus on promising strategies for further improvement of device performance.

42 ENGINEERING↗

Quantum Shell in a Shell: Engineering Colloidal Nanocrystals for a High-Intensity Excitation Regime

Many optoelectronic processes in colloidal semiconductor nanocrystals (NCs) suffer an efficiency decline under high-intensity excitation. This issue is caused by Auger recombination of multiple excitons, which converts the NC energy into excess heat, reducing the efficiency and life span of NC-based devices, including photodetectors, X-ray scintillators, lasers, and high-brightness light-emitting diodes (LEDs). Recently, semiconductor quantum shells (QSs) have emerged as a promising NC geometry for the suppression of Auger decay; however, their optoelectronic performance has been hindered by surface-related carrier losses. Here, we address this issue by introducing quantum shells with a CdS–CdSe–CdS–ZnS core–shell–shell–shell multilayer structure. Further, the ZnS barrier inhibits the surface carrier decay, which increases the photoluminescence (PL) quantum yield (QY) to 90% while retaining a high biexciton emission QY of 79%. The improved QS morphology allows demonstrating one of the longest Auger lifetimes reported for colloidal NCs to date. The reduction of nonradiative losses in QSs also leads to suppressed blinking in single nanoparticles and low-threshold amplified spontaneous emission. We expect that ZnS-encapsulated quantum shells will benefit many applications exploiting high-power optical or electrical excitation regimes.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

A multi-channel x-ray temporal diagnostic for measurement of time-resolved electron temperature in cryogenic deuterium–tritium implosions at OMEGA

Electron-temperature (T e ) measurements in implosions provide valuable diagnostic information, as Te is unaffected by residual flows and other non-thermal effects unlike ion temperature inferred from a fusion product spectrum. In OMEGA cryogenic implosions, measurement of T e (t) can be used to investigate effects related to time-resolved hot-spot energy balance. The proposed diagnostic utilizes five fast-rise (~15 ps) scintillator channels with distinct x-ray filtering. Furthermore, titanium and stepped aluminum filtering were chosen to maximize detector sensitivity in the 10 keV–20 keV range, as it has been shown that these x rays have similar density and temperature weighting to the emitted deuterium–tritium fusion neutrons. Initial data collected using a prototype nosecone on the existing neutron temporal diagnostic demonstrate the validity of this diagnostic technique. The proposed system will be capable of measuring spatially integrated T e (t) with 20 ps time resolution and <10% uncertainty at peak emission in cryogenic DT implosions.

47 OTHER INSTRUMENTATION↗

Thermonuclear neutron emission from a sheared-flow stabilized Z-pinch

We report the fusion Z-pinch experiment (FuZE) is a sheared-flow stabilized Z-pinch designed to study the effects of flow stabilization on deuterium plasmas with densities and temperatures high enough to drive nuclear fusion reactions. Results from FuZE show high pinch currents and neutron emission durations thousands of times longer than instability growth times. While these results are consistent with thermonuclear neutron emission, energetically resolved neutron measurements are a stronger constraint on the origin of the fusion production. This stems from the strong anisotropy in energy created in beam-target fusion, compared to the relatively isotropic emission in thermonuclear fusion. In dense Z-pinch plasmas, a potential and undesirable cause of beam-target fusion reactions is the presence of fast-growing, “sausage” instabilities. This work introduces a new method for characterizing beam instabilities by recording individual neutron interactions in plastic scintillator detectors positioned at two different angles around the device chamber. Histograms of the pulse-integral spectra from the two locations are compared using detailed Monte Carlo simulations. These models infer the deuteron beam energy based on differences in the measured neutron spectra at the two angles, thereby discriminating beam-target from thermonuclear production. An analysis of neutron emission profiles from FuZE precludes the presence of deuteron beams with energies greater than 4.65 keV with a statistical uncertainty of 4.15 keV and a systematic uncertainty of 0.53 keV. This analysis demonstrates that axial, beam-target fusion reactions are not the dominant source of neutron emission from FuZE. These data are promising for scaling FuZE up to fusion reactor conditions.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

The hard x-ray nanotomography microscope at the advanced light source

Beamline 11.3.1 at the Advanced Light Source is a tender/hard (6–17 keV) x-ray bend magnet beamline recently re-purposed with a new full-field, nanoscale transmission x-ray microscope. The microscope is designed to image composite and porous materials possessing a submicrometer structure and compositional heterogeneity that determine materials’ performance and geologic behavior. The theoretical and achieved resolutions are 55 and <100 nm, respectively. The microscope is used in tandem with a <25 nm eccentricity rotation stage for high-resolution volume imaging using nanoscale computed tomography. The system also features a novel bipolar illumination condenser for the illumination of an ~100 μm spot of interest on the sample, followed by a phase-type zone plate magnifying objective of ~52 µm field of view and a phase detection ring. The zone plate serves as the system objective and magnifies the sample with projection onto an indirect x-ray detection system, consisting of a polished single crystal CsI(Tl) scintillator and a range of high-quality Plan Fluorite visible light objectives. The objectives project the final visible light image onto a water-cooled CMOS 2048 × 2048-pixel 2 detector. Here, in this paper, we will discuss the salient features of this instrument and describe early results from imaging the internal three-dimensional microstructure and nanostructure of target materials, including fiber-reinforced composites and geomaterials.

47 OTHER INSTRUMENTATION↗

Online charge measurement for petawatt laser-driven ion acceleration

Laser-driven ion beams have gained considerable attention for their potential use in multidisciplinary research and technology. Preclinical studies into their radiobiological effectiveness have established the prospect of using laser-driven ion beams for radiotherapy. In particular, research into the beneficial effects of ultrahigh instantaneous dose rates is enabled by the high ion bunch charge and uniquely short bunch lengths present for laser-driven ion beams. Such studies require reliable, online dosimetry methods to monitor the bunch charge for every laser shot to ensure that the prescribed dose is accurately applied to the biological sample. In this paper, we present the first successful use of an Integrating Current Transformer (ICT) for laser-driven ion accelerators. This is a noninvasive diagnostic to measure the charge of the accelerated ion bunch. It enables online estimates of the applied dose in radiobiological experiments and facilitates ion beam tuning, in particular, optimization of the laser ion source, and alignment of the proton transport beamline. We present the ICT implementation and the correlation with other diagnostics, such as radiochromic films, a Thomson parabola spectrometer, and a scintillator.

47 OTHER INSTRUMENTATION↗