Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “scan report”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 847 records · Page 47

Ruthenium oxide nanostring clusters anchored Graphene oxide nanocomposites for high-performance supercapacitors application

Highlights: • GO-RuO{sub 2} nanocomposites were synthesized by simple hydrothermal method. • GO-RuO{sub 2} nanocomposites were characterized by XRD, SEM, TEM and EDS. • GO-RuO{sub 2} nanostring composite has shown a maximum specific capacitance of 859 Fg{sup −1} at the scan rate of 5 mVs{sup −1}. • GO-RuO{sub 2} nanostring composite electrode exhibits tremendous cyclic stability. - Abstract: Here, we report simple hydrothermal method for the preparation of Graphene oxide (GO) is embellished with nanostring clusters of ruthenium oxide (GO-RuO{sub 2}). The structure of the nanocomposite material was ascertained using X-ray diffraction (XRD), Raman spectroscopy, Scanning electron spectroscopy (SEM), Energy dispersive spectroscopy (EDS) and Transmission spectroscopy (TEM). The supercapacitor performance of the nanocomposites was investigated in acidic electrolyte, 1.0 M H{sub 2}SO{sub 4}, in a three-electrode setup. GO-RuO{sub 2} nanostring composite has shown a maximum specific capacitance of 859 Fg{sup −1} at the scan rate of 5 mVs{sup −1} using Cyclic voltammetry (CV) and by using Chronopotentiometry (CP) the specific capacitance towered up to 512 Fg{sup −1} at a current density of 2.5 Ag{sup −1}. Further, the material also possesses a high energy density of 246 Wh kg{sup -1}with a maximum power density of 1028 W kg{sup -1}. GO-RuO{sub 2} nanostring composite electrode exhibits tremendous cyclic stability with the specific capacitance retention of nearly 99% of the initial capacitance.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Self-Assembly of Metallo-Supramolecules with Dissymmetrical Ligands and Characterization by Scanning Tunneling Microscopy

Asymmetrical and dissymmetrical structures are widespread and play a critical role in nature and life systems. In the field of metallo-supramolecular assemblies, it is still in its infancy for constructing artificial architectures using dissymmetrical building blocks. Herein, we report the self-assembly of supramolecular systems based on two dissymmetrical double-layered ligands. With the aid of ultra-high-vacuum, low-temperature scanning tunneling microscopy (UHV-LT-STM), we were able to investigate four isomeric structures corresponding to four types of binding modes of ligand LA with two major conformations complexes A. The distribution of isomers measured by STM and total binding energy of each isomer obtained by density functional theory (DFT) calculations suggested that the most abundant isomer could be the most stable one with highest total binding energy. Lastly, through shortening the linker between inner and outer layers and the length of arms, the arrangement of dissymmetrical ligand LB could be controlled within one binding mode corresponding to the single conformation for complexes B.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Exploring Physics of Ferroelectric Domain Walls in Real Time: Deep Learning Enabled Scanning Probe Microscopy

The functionality of ferroelastic domain walls in ferroelectric materials is explored in real-time via the in situ implementation of computer vision algorithms in scanning probe microscopy (SPM) experiment. The robust deep convolutional neural network (DCNN) is implemented based on a deep residual learning framework (Res) and holistically nested edge detection (Hed), and ensembled to minimize the out-of-distribution drift effects. The DCNN is implemented for real-time operations on SPM, converting the data stream into the semantically segmented image of domain walls and the corresponding uncertainty. Further the pre-defined experimental workflows perform piezoresponse spectroscopy measurement on thus discovered domain walls, and alternating high- and low-polarization dynamic (out-of-plane) ferroelastic domain walls in a PbTiO 3 (PTO) thin film and high polarization dynamic (out-of-plane) at short ferroelastic walls (compared with long ferroelastic walls) in a lead zirconate titanate (PZT) thin film is reported. This work establishes the framework for real-time DCNN analysis of data streams in scanning probe and other microscopies and highlights the role of out-of-distribution effects and strategies to ameliorate them in real time analytics.

36 MATERIALS SCIENCE↗

Application Of Laser Induced Breakdown Spectroscopy (LIBS) Technique In Investigation Of Historical Metal Threads

Analysis of the composition of an object is a necessary step in the documentation of the properties of this object for estimating its condition. Also this is an important task for establishing an appropriate conservation treatment of an object or to follow up the result of the application of the suggested treatments. There has been an important evolution in the methods used for analysis of metal threads since the second half of the twentieth century. Today, the main considerations of selecting a method are based on the diagnostic power, representative sampling, reproducibility, destructive nature/invasiveness of analysis and accessibility to the appropriate instrument. This study aims at evaluating the usefulness of the use of Laser Induced Breakdown Spectroscopy (LIBS) Technique for analysis of historical metal threads. In this study various historical metal threads collected from different museums were investigated using (LIBS) technique. For evaluating usefulness of the suggested analytical protocol of this technique, the same investigated metal thread samples were investigated with Scanning Electron Microscope (SEM) with energy-dispersive x-ray analyzer (EDX) which is reported in conservation field as the best method, to determine the chemical composition, and corrosion of investigated metal threads. The results show that all investigated metal threads in the present study are too dirty, strongly damaged and corroded with different types of corrosion products. Laser Induced Breakdown Spectroscopy (LIBS) Technique is considered very useful technique that can be used safely for investigating historical metal threads. It is, in fact, very useful tool as a noninvasive method for analysis of historical metal threads. The first few laser shots are very useful for the investigation of the corrosion and dirt layer, while the following shots are very useful and effective for investigating the coating layer. Higher number of laser shots are very useful for the main composition of the metal thread. There is a necessity to carry out further research to investigate and determine the most appropriate and effective approaches and methods for conservation of these metal threads.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

An improved phase shift reconstruction algorithm of fringe scanning technique for X-ray microscopy

The X-ray phase imaging method has been applied to observe soft biological tissues, and it is possible to image the soft tissues by using the benefit of the so-called “Talbot effect” by an X-ray grating. One type of the X-ray phase imaging method was reported by combining an X-ray imaging microscope equipped by a Fresnel zone plate with a phase grating. Using the fringe scanning technique, a high-precision phase shift image could be obtained by displacing the grating step by step and measuring dozens of sample images. The number of the images was selected to reduce the error caused by the non-sinusoidal component of the Talbot self-image at the imaging plane. A larger number suppressed the error more but increased radiation exposure and required higher mechanical stability of equipment. In this paper, we analyze the approximation error of fringe scanning technique for the X-ray microscopy which uses just one grating and proposes an improved algorithm. We compute the approximation error by iteration and substitute that into the process of reconstruction of phase shift. This procedure will suppress the error even with few sample images. The results of simulation experiments show that the precision of phase shift image reconstructed by the proposed algorithm with 4 sample images is almost the same as that reconstructed by the conventional algorithm with 40 sample images. We also have succeeded in the experiment with real data.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Percutaneous Cryotherapy for Treatment of Chondroblastoma: Early Experience

Surgical curettage is currently the standard of care for the chondroblastoma, but in peri-articular tumors it is limited by its morbidity. In this preliminary report, we evaluate the feasibility of percutaneous cryotherapy as an alternative ablative treatment for chondroblastoma. Three patients with a chondroblastoma treated by CT scan-guided cryotherapy are presented in this article. Pain permanently disappeared 2 days after the procedure. No local tumor recurrence or cartilage damage was observed by MRI performed 1 year after the intervention. This preliminary case report suggests that percutaneous cryotherapy may be a possible alternative to the current standard of care in chondroblastoma. Further studies are needed to evaluate if this technique offers similar anti-tumoral efficacy while providing better pain relief and less morbidity than curettage.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Single-step electrochemical method for producing very sharp Au scanning tunneling microscopy tips

A single-step electrochemical method for making sharp gold scanning tunneling microscopy tips is described. 3.0M NaCl in 1% perchloric acid is compared to several previously reported etchants. The addition of perchloric acid to sodium chloride solutions drastically shortens etching times and is shown by transmission electron microscopy to produce very sharp tips with a mean radius of curvature of 15 nm.

36 MATERIALS SCIENCE↗

Armstrong well

Computed tomography and multi-sensor core logger data for the Armstrong well, primarily Marcellus shale, described in Paronish, T.; Mackey, P.; Crandall, D.; Moore, J.; Brown, S.; Carr, T.; Dinterman, P; Jarvis, K. Computed Tomography Scanning and Geophysical Measurements of the Marcellus Formation from the Armstrong #1 Well; NETL-TRS-17-2018; NETL Technical Report Series; U.S. Department of Energy, National Energy Technology Laboratory: Morgantown, WV, 2018; p 60. DOI: 10.18141/1471662.

Core logging↗

Comprehensive Performance Calibration Guidance for Perovskites and Other Emerging Solar Cells

Emerging photovoltaic (PV) technologies (e.g., organic, perovskite, and solution processed quantum dot) have attracted remarkable attention with the rapid growth of their efficiencies, and their transition toward commercialization. Accurate and reliable efficiency measurements of these PV technologies are crucial, yet much more complicated than for conventional PV technologies due to the former's pronounced dynamic responses to changes in measurement conditions (e.g., current–voltage (I–V) scan rate and preconditioning) and their susceptibility to degradation. Adjustments to the measurement procedures are therefore necessary so that a reproducible “steady state” is reached during measurement. Furthermore, given the small size of many emerging cells, inappropriate device area definition and solar simulator setup can lead to measurement errors. Here, comprehensive efficiency calibration guidance is offered for emerging solar cells, including area measurement; spectral irradiance translation to standard test conditions; and steady-state electrical performance. The necessity of reporting steady-state efficiency is justified with a statistical performance comparison between conventional and steady-state I–V scans over hundreds of cells the group has received globally for efficiency certifications. The procedures described here do not require specialized measurement instrumentation; what matters most are changes to the measurement protocols. These described changes aim to enable better comparisons between reported efficiencies.

14 SOLAR ENERGY↗

Orientation epitaxy of Ge 1–x Sn x films grown on single crystal CaF 2 substrates

Ge 1–x Sn x films were grown via physical vapor deposition below the crystallization temperature of Ge on single crystal (111) and (100) CaF 2 substrates to assess the role of Sn alloying in Ge crystallization. By studying samples grown at several growth temperatures ranging from 250 °C to 400 °C we report temperature-dependent trends in several of the films' properties. X-ray diffraction theta vs. two-theta (θ/2θ) scans indicate single orientation Ge 1–x Sn x (111) films are grown on CaF 2 (111) substrates at each temperature, while a temperature-dependent superposition of (111) and (100) orientations are exhibited in films grown on CaF2(100) above 250 °C. This is the first report of (111) oriented Ge 1–x Sn x grown on a (100) oriented CaF 2 substrate, which is successfully predicted by a superlattice area matching model. These results are confirmed by X-ray diffraction pole figure analysis. θ/2θ results indicate substitutional Sn alloying in each film of about 5%, corroborated by energy dispersive spectroscopy. In addition, morphological and electrical properties are measured by scanning electron microscopy, atomic force microscopy and Hall mobility measurements and are also shown to be dependent upon growth temperature.

36 MATERIALS SCIENCE↗

Mechanism of Electron-Induced Hydrogen Desorption from Hydroxylated Rutile TiO2 (110)

The mechanism of hydrogen desorption from rutile TiO{sub 2}(110)-(1 x 1) was studied by injecting electrons with controlled energy and flux into single surface hydroxyls (OH) in cryogenic scanning tunneling microscopy (STM). Desorption proceeds without a clear threshold already at much lower energies than reported previously. Our analysis identifies a transfer of H atoms from the TiO{sub 2} surface to the STM tip, triggered by vibrational heating due to inelastic electron tunneling, as the desorption mechanism. The reversible H-atom transfer between sample and tip can be used as a tool to discriminate OH from other surface species on TiO{sub 2} and to control the density and configuration of OH by selective removal and redeposition of H atoms on the oxide surface.

08 HYDROGEN↗

Comparative dose evaluations between XVI and OBI cone beam CT systems using Gafchromic XRQA2 film and nanoDot optical stimulated luminescence dosimeters

Purpose: To investigate the effect of energy (kVp) and filters (no filter, half Bowtie, and full Bowtie) on the dose response curves of the Gafchromic XRQA2 film and nanoDot optical stimulated luminescence dosimeters (OSLDs) in CBCT dose fields. To measure surface and internal doses received during x-ray volume imager (XVI) (Version R4.5) and on board imager (OBI) (Version 1.5) CBCT imaging protocols using these two types of dosimeters. Methods: Gafchromic XRQA2 film and nanoDot OSLD dose response curves were generated at different kV imaging settings used by XVI (software version R4.5) and OBI (software version 1.5) CBCT systems. The settings for the XVI system were: 100 kVp/F0 (no filter), 120 kVp/F0, and 120 kVp/F1 (Bowtie filter), and for the OBI system were: 100 kVp/full fan, 125 kVp/full fan, and 125 kVp/half fan. XRQA2 film was calibrated in air to air kerma levels between 0 and 11 cGy and scanned using reflection scanning mode with the Epson Expression 10000 XL flat-bed document scanner. NanoDot OSLDs were calibrated on phantom to surface dose levels between 0 and 14 cGy and read using the inLight{sup TM} MicroStar reader. Both dosimeters were used to measure in field surface and internal doses in a male Alderson Rando Phantom. Results: Dose response curves of XRQA2 film and nanoDot OSLDs at different XVI and OBI CBCT settings were reported. For XVI system, the surface dose ranged between 0.02 cGy in head region during fast head and neck scan and 4.99 cGy in the chest region during symmetry scan. On the other hand, the internal dose ranged between 0.02 cGy in the head region during fast head and neck scan and 3.17 cGy in the chest region during chest M20 scan. The average (internal and external) dose ranged between 0.05 cGy in the head region during fast head and neck scan and 2.41 cGy in the chest region during chest M20 scan. For OBI system, the surface dose ranged between 0.19 cGy in head region during head scan and 4.55 cGy in the pelvis region during spot light scan. However, the internal dose ranged between 0.47 cGy in the head region during head scan and 5.55 cGy in the pelvis region during spot light scan. The average (internal and external) dose ranged between 0.45 cGy in the head region during head scan and 3.59 cGy in the pelvis region during spot light scan. Both Gafchromic XRQA2 film and nanoDot OSLDs gave close estimation of dose (within uncertainties) in many cases. Though, discrepancies of up to 20%-30% were observed in some cases. Conclusions: Dose response curves of Gafchromic XRQA2 film and nanoDot OSLDs indicated that the dose responses of these two dosimeters were different even at the same photon energy when different filters were used. Uncertainty levels of both dosimetry systems were below 6% at doses above 1 cGy. Both dosimetry systems gave almost similar estimation of doses (within uncertainties) in many cases, with exceptions of some cases when the discrepancy was around 20%-30%. New versions of the CBCT systems (investigated in this study) resulted in lower imaging doses compared with doses reported on earlier versions in previous studies.

61 RADIATION PROTECTION AND DOSIMETRY↗

Characterization of Laboratory Prepared Concrete Pastes Exposed to High Alkaline and High Sodium Salt Solutions

The objective of this study was to identify potential chemical degradation mechanisms for the Saltstone Disposal Unit (SDU) concretes, which over the performance life of the structures may be exposed to highly alkaline sodium salt solutions containing sulfate, hydroxide, and other potentially corrosive chemicals in salt solution and saltstone flush water, drain water, leachate and / or pore solution. The samples analyzed in this study were cement pastes prepared in the SIMCO Technologies, Inc. concrete laboratory. They were based on the paste fractions of the concretes used to construct the Saltstone Disposal Units (SDUs). SDU 1 and 4 concrete pastes were represented by the PV1 test specimens. The paste in the SDU 2, 3, 5, and 6 concrete was represented by the PV2 test specimens. SIMCO Technologies, Inc. selected the chemicals and proportions in the aggressive solutions to approximate proportions in the saltstone pore solution [2, 3, 5, and 6]. These test specimens were cured for 56 days in curing chamber before being immersed in aggressive solutions. After exposure, the samples were frozen to prevent additional chemical transport and reaction. Selected archived (retrieved from the freezer) samples were sent to the Savannah River National Laboratory (SRNL) for additional characterization using x-ray diffraction (XRD), scanning electron microscopy (SEM), and energy dispersive x-ray (EDX) spectroscopy. Characterization results are summarized in this report. In addition, a correlation between the oxide composition of the pastes and their chemical durability in the alkaline salt solutions is provided.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Environmental Characterization Scans Using Sodium-Iodide Gamma Spectroscopy to Determine Ra-226 Concentration in Surface Soil - 16326

The recent natural gas drilling boom has brought heightened attention to the issue of TENORM waste management. Radioactive residues from the extraction, treatment, and purification of materials containing uranium and thorium, or their progeny, pose a public health hazard primarily in the form of ground water contamination. Hydraulic fracturing can liberate formation waters from shale; the high salinity of which can cause radium to move with the water to the surface. The disposal and handling of this water has been a subject of public controversy. For soil remediation projects, radium-226 is generally one of the radionuclides of concern due to its alpha emissions. However performing a survey scan for Ra-226 is difficult because its photon emissions are low energy and have minimal probability of emission per decay (186.2 keV, 3.3% abundance). Additionally resolving its emission from U-235 (185.7 keV, 57% abundance) with field instrumentation is not feasible. Therefore detection of Ra-226 relies on the presence and photon emissions of its progeny. This paper outlines methodology for calculating the minimum detectable concentration of Ra-226 in characterization scans using a sodium-iodide detector array coupled with a multi-channel analyzer. Using progeny ingrowth as a detection proxy requires knowing decay time in order to determine progeny emission rates. Knowledge of site history, process, and prior survey results can be key in determining an accurate decay time. However in the absence of such information in-situ measurements can be used to estimate decay time by comparing observed progeny emission ratios against established values. These values are determined using Oak Ridge National Laboratory's ORIGEN-ARP program to generate photon energy spectra for Ra-226 and its progeny at specified time intervals. Once decay time is established, the detector's minimum detectable concentration can be calculated by synthesizing the expected emission spectra and Los Alamos National Laboratory's Monte Carlo N-Particle transport code to simulate detector response. Traditionally, one of the steps in calculating a system's minimum detectable concentration is to place an appropriate button source under the detector, record the response, and then move the source by a specified increment. This process is repeated until the detector's spatial efficiency has been mapped. Due to the impracticality of performing this with Ra-226 button sources of varying decay times, Monte Carlo N-Particle transport code was utilized to determine the detector's spatial efficiency. A dime sized source with the established emission spectra was placed into the center of a rectangle of soil. This rectangle, including the source, was used as a lattice element to fill the region of space below the detector. The simulation was designed to track the energy distribution of pulses created in the sodium iodide crystal using the F8 tally, and was setup to isolate each source; thereby correlating detector response to source position. The simulation output required post-processing to determine conversion factors from counts per second to disintegrations per second. Post-processing accounted for subtraction of the Compton continuum, and average the data over the scanning pattern to obtain the expected spatial sensitivity during a characterization study. This was performed for the following photo-peaks: 609 keV (Bi-214), and 1764 keV (Bi-214). For calculation of the scan minimum detectable concentration, the surveyor efficiency coefficient from NUREG 1507 was supplanted in favor of a scan speed deviation factor. This was used because the detector utilizes computerized data collection (spatial and spectral). This report finds that, for two shielded 10.16 cm x 10.16 cm x 40.64 cm sodium-iodide crystals with integrated multi-channel analyzers, the minimum detectable concentration in surface soils is less than 1 pCi per gram Ra-226 for a 1 second survey measurement. These results assume a volumetric source with a maximum depth of 15.24 cm and a minimum decay time of 21 days. Verification of the system's capabilities was performed by sending soil samples from scanned areas, and locations where in-situ measurements were performed, to an independent laboratory for analysis. The laboratory results demonstrated that scanned area was principally comprised of soil containing less than 1 pCi per gram Ra-226. This borders the system MDC and it underestimated the concentration of radium in the soil. The probable causes of this is escape of radon gas from the surface soil. Radon is the daughter of radium, and has a high mobility in soil. If the gas escapes, then the progeny used as the detection proxy will be present in lower than expected concentrations. Radionuclide identification using high volume sodium-iodide crystals in low level characterization scans is demonstrated to be possible. Further system refinement will focus on developing a methodology to estimate a radon escape factor for site specific use. Accounting for radon escape in the top 15.24 cm of soil will allow the system to better estimate Ra-226 concentrations in soil. This is a significant advancement over the gross counting statistics used in most studies to satisfy MARSSIM survey requirements, because it will increase stakeholder confidence. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

FY17 ISCR Scholar End-of-Assignment Report - Robbie Sadre

Throughout this internship assignment, I did various tasks that contributed towards the starting of the SASEDS (Safe Active Scanning for Energy Delivery Systems) and CES-21 (California Energy Systems for the 21st Century) projects in the SKYFALL laboratory. The goal of the SKYFALL laboratory is to perform modeling and simulation verification of transmission power system devices, while integrating with high-performance computing. The first thing I needed to do was acquire official Online LabVIEW training from National Instruments. Through these online tutorial modules, I learned the basics of LabVIEW, gaining experience in connecting to NI devices through the DAQmx API as well as LabVIEW basic programming techniques (structures, loops, state machines, front panel GUI design etc).

24 POWER TRANSMISSION AND DISTRIBUTION↗

Development and investigation of single-scan TV radiography for the acquisition of dynamic physiologic data

Research data obtained by the low dose electronic radiography system are reported. Data cover: (1) localization and tracking of Ta screws implanted in the inner wall of the right ventrical of the heart, (2) use of cross hairs to outline inner or outer heart wall contours, (3) quantitative measure of anatomical components which are stationary in size or change size dynamically, and (4) study of dynamic quantitative data from roentenologic or fluoroscopic procedures.

Baily, N. A.↗