Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “room temperature”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 847 records · Page 47

The Preparation Conditions of Chromium Doped ZnSe and Their Effect on The Infrared Luminescence Properties

We report the investigation by photoluminescence lifetime measurements of the near-IR emissions from a series of chromium-doped ZnSe samples, correlated to their preparation conditions. The samples were polycrystalline or single crystals prepared by post growth diffusion doping or single crystals doped during growth by the Physical Vapor Transport method. Room temperature lifetime values between 6 and 8 microseconds were measured for samples with Cr (2+) concentrations from low 10 (exp 17) to high 10 (exp 18) per cubic centimeter range. Lifetime data taken down to 78 K was found to be rather temperature independent, reconfirming previous reports indicating a quantum yield of the corresponding emission of close to 100% at room temperature. A strong decrease in the room temperature lifetime was found for chromium concentrations higher than 10 (exp 19) per cubic centimeter.

Burger, A.↗

The Preparation Conditions of Chromium Doped ZnSe and Their Effect on the Infrared Luminescence Properties

We report the investigation by photoluminescence lifetime measurements of the near-IR emissions from a series of chromium-doped ZnSe samples, correlated to their preparation conditions. The samples were polycrystalline or single crystals prepared by post growth diffusion doping or single crystals doped during growth by the physical vapor transport method. Room temperature lifetime values between 6 and 8 micro seconds were measured for samples with Cr2+ from low 10(exp 17) to high 10(exp 18) / cubic cm range. Lifetime data taken down to 78 K was found to be rather temperature independent, reconfirming previous reports indicating a quantum yield of the corresponding emission of close to 100% at room temperature. A strong decrease in the room temperature lifetime was found for chromium concentrations higher than 10(exp 19) / cubic CM.

Burger, A.↗

Semihard magnetic properties of TiFe 2.5 iron-rich Laves phase and the effect of 4d- and 5d-element-substitutions for Ti

Rare-earth-free compounds exhibiting modest intrinsic hard magnetic properties may still yield viable permanent magnets if their constituent elements are abundant and inexpensive, and the properties are at least comparable to those of the hard ferrites. In this study, one such compound, the off-stoichiometric TiFe 2.5 Laves phase with the hexagonal C14 crystal structure, was found to exhibit – in addition to the already known room-temperature ferromagnetism – a uniaxial, albeit weak, magnetic anisotropy. With a Curie temperature of 422 K, saturation magnetization of 55.3 Am 2 /kg and magnetic hardness parameter of 0.97 this semihard compound is just below the threshold for being of interest for the development into permanent magnets. Replacing a small fraction of Ti with the 4d Nb and Mo or with the 5d Ta or W increases the anisotropy field, but only below room temperature. Replacing Ti with Zr or Hf increases the Curie temperature and leads to a spin reorientation below 200 K. All these substitutions, as well as combined (Zr,W) and (Nb,W) substitutions, fail to improve the room-temperature intrinsic hard magnetic properties of the Fe-rich Laves phase. Furthermore, an attempt to develop a room-temperature coercivity through high-energy ball-milling yielded a value of 0.026 T, an unusually small 2.9% fraction of the anisotropy field. Here, defects inherent in the C14 crystal lattice may be responsible for the underperformance.

36 MATERIALS SCIENCE↗

Microstructure and property characterization of sintered Si3N4, SiC, and SiAlON

Commercially-produced, pressureless sintered Si3N4, SiC, and SiAlON were characterized with respect to density, phases present, bend strength, and oxidation resistance. The room-temperature bend strengths of sintered Si3N4, SiC, and SiAlON are comparable. However, the room-temperature strengths are much lower (approximately 40 to 50%) than the room-temperature strength of hot-pressed Si3N4 (NC-132). The strength loss in Si3N4 and SiAlON materials at high temperature was attributed to a viscous grain-boundary phase, retained during cooling from the sintering temperature. The oxidation resistance of sintered alpha-SiC was the best of any materials tested.

Dutta, S.↗

Pyroelectric detectors

The multi-agency, long-term Global Change programs, and specifically NASA's Earth Observing system, will require some new and advanced photon detector technology which must be specifically tailored for long-term stability, broad spectral range, cooling constraints, and other parameters. Whereas MCT and GaAs alloy based photovoltaic detectors and detector arrays reach most impressive results to wavelengths as long as 12 microns when cooled to below 70 K, other materials, such as ferroelectrics and pyroelectrics, appear to offer special opportunities beyond 12 microns and above 70 K. These materials have found very broad use in a wide variety of room temperature applications. Little is known about these classes of materials at sub-room temperatures and no photon detector results have been reported. From the limited information available, researchers conclude that the room temperature values of D asterisk greater than or equal to 10(exp 9) cm Hz(exp 1/2)/W may be improved by one to two orders of magnitude upon cooling to temperatures around 70 K. Improvements of up to one order of magnitude appear feasible for temperatures achievable by passive cooling. The flat detector response over a wavelength range reaching from the visible to beyond 50 microns, which is an intrinsic advantage of bolometric devices, makes for easy calibration. The fact that these materials have been developed for reduced temperature applications makes ferro- and pyroelectric materials most attractive candidates for serious exploration.

Haller, Eugene E.↗

Exploring transport mechanisms in atomic precision advanced manufacturing enabled pn junctions

We investigate the different transport mechanisms that can occur in pn junction devices made using atomic precision advanced manufacturing at temperatures ranging from cryogenic to room temperature. We first elucidate the potential cause of the anomalous behavior observed in the forward-bias response of these devices in recent cryogenic temperature measurements, which deviates from the theoretical response of a silicon Esaki diode. These anomalous behaviors include current suppression at low voltages in the forward-bias response and a much lower valley voltage at cryogenic temperatures than theoretically expected for a silicon diode. To investigate the potential causes of these anomalies, we studied the effects of a few possible transport mechanisms, including band-to-band tunneling, bandgap narrowing, potential impact of non-Ohmic contacts, band quantization, impact of leakage, and inelastic trap-assisted tunneling, through semi-classical simulations. We find that a combination of two sets of band-to-band tunneling (BTBT) parameters can qualitatively approximate the shape of the tunneling current at low bias. This can arise from band quantization and realignment due to the strong potential confinement in δ-layers. We also find that the lower-than-theoretically-expected valley voltage can be attributed to modifications in the electronic band structure within the δ-layer regions, leading to a significant bandgap narrowing induced by the high density of dopants. Finally, we extend our analyses to room temperature operation and predict that trap-assisted tunneling (TAT) facilitated by phonon interactions may become significant, leading to a complex superposition of BTBT and TAT transport mechanisms in the electrical measurements.

band gap↗

Temperature dependence of viscoelastic Poisson’s ratio of cement mortar

Abstract Concrete creep research has focused primarily on uniaxial response. However, biaxially prestressed concrete structures are common, resulting in a multiaxial stress state that can complicate the behavior of a viscoelastic material like concrete. Significant creep strains may be induced in directions transverse to each principle stress due to Poisson’s effect. Past research is unclear regarding the viscoelastic or viscoplastic properties of concrete outside of uniaxial response. It has been reported in separate studies that concrete viscoelastic/viscoplastic Poisson’s ratio (VPR) is an increasing, decreasing and constant function with time, with all reported measurements performed at room temperature. In this paper, the 3D basic creep response of mature cement mortar is examined using a confined compression experiment that allows direct determination of the full stress and infinitesimal strain tensors in a single test, which enables the determination of VPR under a multiaxial stress state. For this purpose, a unique, miniature version of the standardized concrete creep frame is designed that is amenable to placing in climate chambers and temperature ovens. The experimental results indicate that the VPR of sealed, mature cement mortar is nearly constant and equal to the elastic at room temperature, while the VPR gradually increases with time when measured at 60 °C.

Construction & Building Technology↗

Bend strengths of reaction bonded silicon nitride prepared from dry attrition milled silicon powder

Dry attrition milled silicon powder was compacted, sintered in helium, and reaction bonded in nitrogen-4 volume percent hydrogen. Bend strengths of bars with as-nitrided surfaces averaged as high as 210 MPa at room temperature and 220 MPa at 1400 C. Bars prepared from the milled powder were stronger than those prepared from as-received powder at both room temperature and at 1400 C. Room temperature strength decreased with increased milling time and 1400 C strength increased with increased milling time.

Herbell, T. P.↗

Depicting the roles of CuO secondary phase and heat treatment in driving the magnetic and magnetocaloric features of Pr 2/3 Sr 1/3 MnO 3 manganite

In this work, we report a detailed experimental study regarding the impact of copper oxide (CuO) secondary phase and heat treatments on the structural, magnetic, and magnetocaloric properties of the near-room temperature Pr 2/3 Sr 1/3 MnO 3 (PSMO) magnetic refrigerant. Our investigations are carried out by using structural and microstructural analyses, alongside magnetization measurements. Here, the analysis of X-ray diffraction data of PSMO(95%)-CuO(5%) (PSMO-CuO) samples shows the coexistence of both CuO and PSMO phases. Further, the microstructural analysis of PSMO-CuO reveals that the addition of CuO significantly enhances the grains size. On the other hand, the added secondary phase markedly reduces the Curie temperature (T c ) from 293 K for PSMO to about 273 K for PSMO-CuO composite while increasing the magnetocaloric effect. This decrease in T c is associated with a significant change from 162° to about 156° in the Mn-OII-Mn bond angle respectively. Moreover, performed investigations regarding the role of heat treatments unveil that the observed changes in the structural and magnetic features are mainly driven by the secondary phase that modify grains size and double-exchange interactions in the PSMO compound. Interestingly, our findings demonstrate that the Curie temperature of the PSMO and accordingly its magnetocaloric effect can be tailored by adding small amounts of CuO without need to substitution on cation sites. In the light of obtained results, a multilayered refrigerant composed of PSMO and PSMO-CuO is proposed to cover the magnetic cooling temperature range close to room-temperature. The resulting entropy change remains practically constant between 273 K and 293 K. Such a behavior is highly appreciated from a practical point of view, particularly in cases where the cooling process is carried out by using the AMR and Ericsson cycles.

36 MATERIALS SCIENCE↗

Cryogenic Transport of High-Pressure-System Recharge Gas

A method of relatively safe, compact, efficient recharging of a high-pressure room-temperature gas supply has been proposed. In this method, the gas would be liquefied at the source for transport as a cryogenic fluid at or slightly above atmospheric pressure. Upon reaching the destination, a simple heating/expansion process would be used to (1) convert the transported cryogenic fluid to the room-temperature, high-pressure gaseous form in which it is intended to be utilized and (2) transfer the resulting gas to the storage tank of the system to be recharged. In conventional practice for recharging high-pressure-gas systems, gases are transported at room temperature in high-pressure tanks. For recharging a given system to a specified pressure, a transport tank must contain the recharge gas at a much higher pressure. At the destination, the transport tank is connected to the system storage tank to be recharged, and the pressures in the transport tank and the system storage tank are allowed to equalize. One major disadvantage of the conventional approach is that the high transport pressure poses a hazard. Another disadvantage is the waste of a significant amount of recharge gas. Because the transport tank is disconnected from the system storage tank when it is at the specified system recharge pressure, the transport tank still contains a significant amount of recharge gas (typically on the order of half of the amount transported) that cannot be used. In the proposed method, the cryogenic fluid would be transported in a suitably thermally insulated tank that would be capable of withstanding the recharge pressure of the destination tank. The tank would be equipped with quick-disconnect fluid-transfer fittings and with a low-power electric heater (which would not be used during transport). In preparation for transport, a relief valve would be attached via one of the quick-disconnect fittings (see figure). During transport, the interior of the tank would be kept at a near-ambient pressure far below the recharge pressure. As leakage of heat into the tank caused vaporization of the cryogenic fluid, the resulting gas would be vented through the relief valve, which would be set to maintain the pressure in the tank at the transport value. Inasmuch as the density of a cryogenic fluid at atmospheric pressure greatly exceeds that of the corresponding gas in a practical high-pressure tank at room temperature, a tank for transporting a given mass of gas according to the proposed method could be smaller (and, hence, less massive) than is a tank needed for transporting the same mass of gas according to the conventional method.

Ungar, Eugene K,↗

Ductility in rapidly solidified NiAl

An attempt is made to refine the grain structure of equiatomic NiAl by means of rapid solidification processing, and to examine the effect of small grain size on room temperature ductility. Free melt spinning was used to produce the rapidly solidified material. Room temperature bend testing of both as-spun and heat-treated NiAl ribbon was conducted by free bending the ribbon around a mandrel of successively smaller diameter until failure occurred. Room-temperature plastic deformation was exhibited both before and after a 1-h heat treatment at 1000 C. Heat treatment increased the observed ductility.

Gaydosh, D. J.↗

Lifetimes of bacteriochlorophyll fluorescence in Rhodopseudomonas viridis and Heliobacterium chlorum at low temperatures

Fluorescence lifetimes of isolated membranes of Rhodopseudomonas viridis were measured in the temperature range of 77 K to 25 K. At room temperature, the main component of the fluorescence decay of bacteriochlorophyll (BChl) b had a time constant of 50 ps. In contrast to other purple bacteria, the emission at low temperature was spectrally homogeneous and showed essentially single lifetimes of 140 ps at 77 K and 180 ps at 25 K, with the primary electron donor in the oxidized state. Taking into account the relative fluorescence yields with open and closed reaction centers, we arrive at numbers of 125 ps and 215 ps, respectively, for open reaction centers. These numbers are significantly smaller than expected on the basis of measurements of the efficiency of charge separation, perhaps suggesting that the excitation decay in the absence of reaction centers is considerably faster at low temperature than at room temperature. At least four different spectral components with different lifetimes were observed at 25 K in the emission of Heliobacterium chlorum, a short-wavelength component of about 30 ps and three longer-wavelength components of about 100 ps, 300 ps, and 900 ps. This indicates a strong heterogeneity in the emitting pigment, BChl g-808. The component with the shortest lifetime does not appear to be affected by the redox state of the reaction center and might reflect energy transfer to BChl g species which are connected to the reaction center.

NASA Discipline Number 52-30↗

Quantitative Microstructural Characterization of Plutonium Oxalate Auto-Degradation and Evidence for PuO2 Nanocrystal Formation

It has been known since the 1950s that plutonium oxalate powders change color and lose mass over time when stored at room temperature in air. Despite several studies monitoring these changes, there are still discrepancies in the literature regarding the speciation of intermediate and final products that result from this decomposition. Presented here for the first time is a comprehensive series of time-resolved powder X-ray diffraction experiments coupled with solid-state optical spectroscopy and electron microscopy of aged plutonium (III) and (IV) oxalate powders. These data provide fresh insight into the chemical and structural changes that occur in these solids over time at room temperature and represent new evidence suggesting both plutonium (III) and plutonium (IV) oxalates decompose to form nanocrystalline plutonium oxide in the solid state.

Corbey, Jordan F.↗

Conceptual design of the modular detector and readout system for the CMB-S4 survey experiment

We present the conceptual design of the modular detector and readout system for the Cosmic Microwave Background – Stage four (CMB-S4) ground-based survey experiment. CMB-S4 will map the cosmic microwave background (CMB) and the millimeter-wave sky to unprecedented sensitivity, using 500,000 superconducting detectors observing from Chile and Antarctica to map over 60% of the sky. The fundamental building block of the detector and readout system is a detector module package operated at 100 mK, which is connected to a readout and amplification chain that carries signals out to room temperature. It uses arrays of feedhorn-coupled orthomode transducers (OMT) that collect optical power from the sky onto dc-voltage-biased transition-edge sensor (TES) bolometers. The resulting current signal in the TESs is then amplified by a two-stage cryogenic Superconducting Quantum Interference Device (SQUID) system with a time-division multiplexer to reduce wire count, and matching room-temperature electronics to condition and transmit signals to the data acquisition system. Sensitivity and systematics requirements are being developed for the detector and readout system over wide range of observing bands (20 to 300 GHz) and optical powers to accomplish CMB-S4’s science goals. While the design incorporates the successes of previous generations of CMB instruments, CMB-S4 requires an order of magnitude more detectors than any prior experiment. This requires fabrication of complex superconducting circuits on over 10 m2 of silicon, as well as significant amounts of precision wiring, assembly and cryogenic testing

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Role of Zeolite Structural Properties toward Iodine Capture: A Head-to-head Evaluation of Framework Type and Chemical Composition

This study evaluated zeolite-based sorbents for iodine gas [I2(g)] capture. Based on the framework structures and porosities, five zeolites, including two faujasite (FAU), one ZSM-5 (MFI), one mesoMFI, one ZSM-22 (TON), as well as two mesoporous materials, were evaluated for I2(g) capture at room temperature and 150 °C in an iodine-saturated environment. From these preliminary studies, the three best-performing zeolites were ion-exchanged with Ag+ and evaluated for I2(g) capture under similar conditions. Energy-dispersive X-ray spectroscopy data suggest that Ag-FAU frameworks were the materials with the highest capacity for I2(g) in this study, showing ~3× higher adsorption compared to Ag-mordenite (Ag-MOR) at room temperature, but X-ray diffraction measurements show that the faujasite structure collapsed during the adsorption studies because of dealumination. The Ag-MFI zeolites are decent sorbents in real-life applications, showing both good sorption capacities and higher stability. In-depth analyses and characterizations, including synchrotron X-ray absorption spectroscopy, revealed the influence of structural and chemical properties of zeolites on the performance for iodine adsorption from the gas phase.

aluminosilicate zeolites, iodine, porosity, acidit↗

Preliminary Modeling of CH3D From 4000 to 4550 cm (exp-1)

A new study of 12CH3D line positions and intensities was performed for the upper portion of the Enneadecad polyad between 4000 and 4550/cm. For this, FTIR spectra were recorded with D-enriched methane samples (at 80 K with a Bruker 125 IFS at 0.005/cm resolution and at 291 K with the McMath-Pierce FTS at 0.011/cm resolution, respectively). Line positions and intensities were retrieved by least square curve-fitting procedures and analyzed using the effective Hamiltonian and the effective dipole moment expressed in terms of irreducible tensor operators adapted to symmetric top molecules. Initially, only the cold spectrum was used to identify quantum assignments and predict 12CH3D relative intensities in this region. To assign higher quanta up to J equal 14, additional line positions and intensities were obtained from two room temperature spectra. In the final stage, measured intensities from both the cold and the room temperature data were normalized to corresponding values at 296 K and then averaged. Combining the two temperature datasets confirmed the assumed quantum assignments and also demonstrated the relative accuracies to be better than 70.0002/cm for line positions and at least +/-6% for intensities so that approx.1160 features were selected. Including additional assignments from the room temperature spectra alone permitted 1362 line intensities of 11 bands (involving 23 vibrational symmetry components) to be reproduced with an RMS of 9%. Over 4085 selected positions for 12 bands were modeled to 0.008/cm. Nevertheless a number of known assignments could not be modeled to within our experimental precisions. More work is needed to obtain a complete characterization of this complex polyad.

Nikitin, A. V.↗

Low-temperature operation of a Buck DC/DC converter

Low-temperature (77 K) operation of a 42/28 V, 175 W, 50 kHz PWM Buck DC/DC converter designed with commercially available components is reported. Overall, the converter losses decreased at 77 K compared to room temperature operation. A full-load efficiency of 97 percent was recorded at liquid-nitrogen temperature, compared to 95.8 percent at room temperature. Power MOSFET operation improved significantly where as the output rectifier operation deteriorated at low-temperature. The performance of the output filter inductor and capacitor did not change significantly at 77 K compared to room temperature performance. It is possible to achieve high-density and high efficiency power conversion at low-temperatures due to improved electronic, electrical and thermal properties of materials.

Ray, Biswajit↗

Evaluation results of the 700 deg C Chinese strain gauges

Gauges fabricated from specially developed Fe-Cr-Al-V-Ti-Y alloy wire in the Republic of China were evaluated for use in static strain measurement of hot gas turbine engines. Gauge factor variation with temperature, apparent strain, and drift were included. Results of gauge factor versus temperature tests show gauge factor decreasing with increasing temperature. The average slope is -3-1/2 percent/100 K, with an uncertainty band of + or - 8 percent. Values of room temperature gauge factor for the Chinese and Kanthal A-1 gauges averaged 2.73 and 2.12, respectively. The room temperature gauge factor of the Chinese gauges was specified to be 2.62. The apparent strain data for both the Chinese alloy and Kanthal A-1 showed large cycle to cycle nonrepeatability. All apparent strain curves had a similar S-shape, first going negative and then rising to positive value with increasing temperatures. The mean curve for the Chinese gauges between room temperature and 100 K had a total apparent strain of 1500 microstrain. The equivalent value for Kanthal A-1 was about 9000 microstrain. Drift tests at 950 K for 50 hr show an average drift rate of about -9 microstrain/hr. Short-term (1 hr) rates are higher, averaging about -40 microstrain for the first hour. In the temperature range 700 to 870 K, however, short-term drift rates can be as high as 1700 microstrain for the first hour. Therefore, static strain measurements in this temperature range should be avoided.

Hobart, H. F.↗