Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “radiation testing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 847 records · Page 47

Three-body collisions in a plasma in a strong laser field

Electron-ion collisions in a high-density plasma in strong electromagnetic fields are considered. The applicability condition for the approximate model of pair collisions in strong fields are determined. It is shown that this condition is identical to the condition for the plasma to be transparent. Investigations were carried out by the test particle method generalized to the case of several scattering centers. An accurate calculation of short-range collisions is provided by a 'jump' method that is based on the exact solution to the problem of the motion of a particle in a Coulomb potential. This method can also be applied in other approaches to simulating a collisional plasma (such as particle-in-cell and molecular dynamics methods).

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Characterization of the neutron flux during production of 18 F at a medical cyclotron and evaluation of the incidental neutron spectrum for neutron damage studies

The fast neutron spectrum was measured an irradiation position adjacent to two 18 F (fluorine-18) production targets at a medical cyclotron. The neutron spectrum was modeled using MCNP6 and experimentally determined using activation foils. A three-group neutron spectrum was determined using an over-determined least squares fitting method. The MCNP6 model results and measurements of the activation foils were used as input to unfold the neutron spectrum using the PNNL-STAYSL code. The neutron spectrum adjacent to the 18 F production target was evaluated for use in incidental experiments to evaluate neutron induced radiolysis of polyurethane and radiation hardness testing of electronics. The fast neutron flux near the 18 F target between the energies of 0.4 – 16.5 MeV was 1.8 – 3.0x10 9 n cm -2 s -1 . The neutron dose rate in polyurethane at the irradiation position was 2.8 cGy s -1 – 5.8 cGys -1 . The 1 MeV equivalent neutron flux was 2.4x10 9 n cm -2 s -1 – 4.0x10 9 n cm -2 s -1 .

18F-fluorodeoxyglucose↗

Effects of incandescent radiation on photosynthesis, growth rate and yield of 'Waldmann's Green' leaf lettuce

Effects of different ratios incandescent (ln) to fluorescent (Fl) radiation were tested on growth of 'Waldmann's Green' leaf lettuce (Lactuca sativa L.) in a controlled environment. After 4 days of treatment, dry weight, leaf area, relative growth rate (RGR), net assimilation rate (NAR), leaf area ratio (LAR) and photosynthetic rate (Pn) were greater for plants grown at 84 rather than 16% of total irradiance (82 W m-2) from ln lamps. Although leaf dry weight and area were 12-17% greater at 84% ln after the first 8 days of treatment, there were no differences in RGR or Pn between treatments during the last 4 days. If 84% ln was compared with 50% ln, all cumulative growth parameters, RGR, NAR and Pn were greater for 84% ln during the first 4 days of treatment. However, during the second 4 days, RGR was greater for the 50% ln treatment, resulting in no net difference in leaf dry weight or area between treatments. Shifting from 84 to 50% ln radiation between the first and second 4 days of treatment increased plant dry weight, leaf area, RGR and NAR relative to those under 84% ln for 8 days continuously.

NASA Program CELSS↗

Breakdown in Tantalum Capacitors

Failures in tantalum capacitors can be considered as a time-dependent-breakdown and reliability of all types of capacitors, including wet, MnO2 and polymer cathode parts, depends on the efficiency of self-healing that can mend parts after breakdown. A mechanism of self-healing in MnO2 capacitors is associated with oxygen reduction in the cathode layer and isolation of the breakdown site with high-resistive Mn2O3/Mn3O4 compositions. Although this mechanism is commonly accepted, details of self-healing have not been analyzed sufficiently yet, and the effects of scintillations on behavior of the parts has not been fully understood. There is a lack of data on the self-healing efficiency in different lots of capacitors. Even less is known about self-healing in polymer tantalum capacitors. In this work, different types of polymer and MnO2 capacitors have been tested for scintillation breakdown using a constant current stress (CCS) technique modified to allow detection of the amplitudes and durations of current spikes during breakdown. Characteristics of the parts and in particular leakage currents were measured to assess the efficiency of self-healing and improve screening processes for tantalum capacitors. Damaged sites were localized using infrared camera and their appearance analyzed after deprocessing and crosssectioning. Thermal effects during scintillations have been modeled, self-healing processes in polymer and MnO2 cathode capacitors discussed, and mechanisms of breakdown based on the growth of conductive filaments in the dielectric suggested.

tantalum polymer capacitors↗

Effects of incandescent radiation on photosynthesis, growth rate and yield of 'Waldmann's Green' leaf lettuce

Effects of different ratios of incandescent (ln) to fluorescent (Fl) radiation were tested on growth of 'Waldmann's Green' leaf lettuce in a controlled environment. After 4 days of treatment, dry weight, leaf area, relative growth rate (RGR), net assimilation rate (NAR), leaf area ratio (LAR) and photosynthetic rate (Pn) were greater for plants grown at 84 rather than 16 percent of total irradiance (82 W/sq m) from ln lamps. Although leaf dry weight and area were 12-17 percent greater at 84 percent ln after the first 8 days of treatment, there were no differences in RGR or Pn between treatments during the last 4 days. If 84 percent ln was compared with 50 percent ln, all cumulative growth parameters, RGR, NAR and Pn were greater for 84 percent ln during the first 4 days of treatment. However, during the second 4 days, RGR was greater for the 50 percent ln treatment, resulting in no net difference in leaf dry weight or area between treatments. Shifting from 84 to 50 percent ln radiation between the first and second 4 days of treatment increased plant dry weight, leaf area, RGR and NAR relative to those under 84 percent ln for 8 days continuously.

Knight, Sharon L.↗

Fractionated External Beam Radiotherapy as a Suitable Preparative Regimen for Hepatocyte Transplantation After Partial Hepatectomy

Purpose: Hepatocyte transplantation is strongly considered to be a promising option to correct chronic liver failure through repopulation of the diseased organ. We already reported on extensive liver repopulation by hepatocytes transplanted into rats preconditioned with 25-Gy single dose selective external beam irradiation (IR). Herein, we tested lower radiation doses and fractionated protocols, which would be applicable in clinical use. Methods and Material: Livers of dipeptidylpeptidase IV (DPPIV)-deficient rats were preconditioned with partial liver external beam single dose IR at 25 Gy, 8 Gy, or 5 Gy, or fractionated IR at 5 x 5 Gy or 5 x 2 Gy. Four days after completion of IR, a partial hepatectomy (PH) was performed to resect the untreated liver section. Subsequently, 12 million wild-type (DPPIV{sup +}) hepatocytes were transplanted via the spleen into the recipient livers. The degree of donor cell integration and liver repopulation was studied 16 weeks after transplantation by means of immunofluorescence and DPPIV-luminescence assay. Results: Donor hepatocyte integration and liver repopulation were more effective in the irradiated livers following pretreatment with the IR doses 1 x 25 Gy and 5 x 5 Gy (formation of large DPPIV-positive cell clusters) than single-dose irradiation at 8 Gy or 5 Gy (DPPIV-positive clusters noticeably smaller and less frequent). Quantitative analysis of extracted DPPIV revealed signals exceeding the control level in all transplanted animals treated with IR and PH. Compared with the standard treatment of 1 x 25 Gy, fractionation with 5 x 5 Gy was equally efficacious, the Mann-Whitney U test disclosing no statistically significant difference (p = 0.146). The lower doses of 1 x 5 Gy, 1 x 8 Gy, and 5 x 2 Gy were significantly less effective with p < 0.05. Conclusion: This study suggests that fractionated radiotherapy in combination with PH is a conceivable pretreatment approach to prime the host liver for hepatocyte transplantation, thus bringing the experimental model a step closer to clinical application.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Integrated Advanced Microwave Sounding Unit-A (AMSU-A). Test Report, Electromagnetic Interference (EMI)/Electromagnetic Radiation(EMR) and Electromagnetic Capability (EMC) for the EOS/AMSU-A1

This document contains the procedure and the test results of the Advanced Microwave Sounding Unit-A (AMSU-A) Earth Observing System (EOS) Project, assembly part number 1356008-1, serial number 202, Electromagnetic Interference (EMI) and Electromagnetic Susceptibility (EMC) qualification test. The test was conducted in accordance with the approved EMI/EMC Test Plan/Procedure, Specification number AE-26151/8B, dated 10 September 1998. Aerojet intends that the presentation and submittal of this document, prepared in accordance with the objectives established by the aforementioned Test Plan/Procedure, document number AE-26151/8B, will satisfy the data requirement with respect to the AMSU-A/EOS instrument operational compliance of the EMI/EMC test requirement. Test for the AMSU-A/EOS instrument have been completed and all the requirements per General Interface Requirement Document (GIRD), GSFC 422-11-12-01, for EOS Common Spacecraft/Instruments, paragraph 10.11, were met with the exceptions of the test methods CE03, RE01, and RE02, as described in this document.

Paliwoda, L.↗

Comparison of MCNP and Experimental Measurements for an HPGe-based Spectroscopy Portal Monitor.

The necessity to monitor international commercial transportation for illicit nuclear materials resulted in the installation of many nuclear radiation detection systems in Portal Monitors. These were mainly gross counters which alarmed at any indication of high radioactivity in the shipment, the vehicle or even the driver. The innocent alarm rate, due to legal shipments of sources and NORM, or medical isotopes in patients, caused interruptions and delays in commerce while the legality of the shipment was verified. To overcome this difficulty, Department of Homeland Security (DHS) supported the writing of the ANSI N42.38 standard (Performance Criteria for Spectroscopy-Based Portal Monitors used for Homeland Security) to define the performance of a Portal Monitor with nuclide identification capabilities, called a Spectroscopy Portal Monitor. This standard defines detection levels and response characteristics for the system for energies from 25 keV to3. MeV. To accomplish the necessary performance, several different HPGe detector configurations were modeled using MCNP for the horizontal field of view (FOV) and vertical linearity of response over the detection zone of 5 meters by 4.5 meters for 661 keV as representative of the expected nuclides of interest. The configuration with the best result was built and tested. The results for the FOV as a function of energy and the linearity show good agreement with the model and performance exceeding the requirements of N42.38.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Optimization of spectroscopic surveys for testing non-Gaussianity

We investigate optimization strategies to measure primordial non-Gaussianity with future spectroscopic surveys. We forecast measurements coming from the 3D galaxy power spectrum and compute constraints on primordial non-Gaussianity parameters f{sub NL} and n{sub NG}. After studying the dependence on those parameters upon survey specifications such as redshift range, area, number density, we assume a reference mock survey and investigate the trade-off between number density and area surveyed. We then define the observational requirements to reach the detection of f{sub NL} of order 1. Our results show that power spectrum constraints on non-Gaussianity from future spectroscopic surveys can improve on current CMB limits, but the multi-tracer technique and higher order correlations will be needed in order to reach an even better precision in the measurements of the non-Gaussianity parameter f{sub NL}.

79 ASTRONOMY AND ASTROPHYSICS↗

Langmuir probes for SPIDER (source for the production of ions of deuterium extracted from radio frequency plasma) experiment: Tests in BATMAN (Bavarian test machine for negative ions)

A prototype system of the Langmuir probes for SPIDER (Source for the production of Ions of Deuterium Extracted from RF plasma) was manufactured and experimentally qualified. The diagnostic was operated in RF (Radio Frequency) plasmas with cesium evaporation on the BATMAN (BAvarian Test MAchine for Negative ions) test facility, which can provide plasma conditions as expected in the SPIDER source. A RF passive compensation circuit was realised to operate the Langmuir probes in RF plasmas. The sensors’ holder, designed to better simulate the bias plate conditions in SPIDER, was exposed to a severe experimental campaign in BATMAN with cesium evaporation. No detrimental effect on the diagnostic due to cesium evaporation was found during the exposure to the BATMAN plasma and in particular the insulation of the electrodes was preserved. The paper presents the system prototype, the RF compensation circuit, the acquisition system (as foreseen in SPIDER), and the results obtained during the experimental campaigns.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

An interactive ontology-driven information system for simulating background radiation and generating scenarios for testing special nuclear materials detection algorithms

This paper describes an original approach to generating scenarios for the purpose of testing the algorithms used to detect special nuclear materials (SNM) that incorporates the use of ontologies. Separating the signal of SNM from the background requires sophisticated algorithms. To assist in developing such algorithms, there is a need for scenarios that capture a very wide range of variables affecting the detection process, depending on the type of detector being used. To provide such a cpability, we developed an ontology-driven information system (ODIS) for generating scenarios that can be used in creating scenarios for testing of algorithms for SNM detection. The ontology-driven scenario generator (ODSG) is an ODIS based on information supplied by subject matter experts and other documentation. The details of the creation of the ontology, the development of the ontology-driven information system, and the design of the web user interface (UI) are presented along with specific examples of scenarios generated using the ODSG. We demonstrate that the paradigm behind the ODSG is capable of addressing the problem of semantic complexity at both the user and developer levels. Compared to traditional approaches, an ODIS provides benefits such as faithful representation of the users' domain conceptualization, simplified management of very large and semantically diverse datasets, and the ability to handle frequent changes to the application and the UI. Furthermore, the approach makes possible the generation of a much larger number of specific scenarios based on limited user-supplied information

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Improvements in the Method of Radiation Anomaly Detection by Spectral Comparison Ratios

Algorithms for detecting illicit gamma radiation sources must respond to a wide variety of threat signatures and ignore a wider variety of clutter. Previously, we described the Nuisance-rejection Spectral Comparison Ratio Anomaly Detection (N-SCRAD) method for indicating the presence of threat sources during mobile search operations. Our method relies on the formulation of radiation alarm test statistics applied to detector counts in numerous spectral regions of interest and our test statistics are standardized by local estimates of background variability. In this work we present a new automated procedure for selecting test statistics and specifying the regions of interest based on minimizing detectable count rates of prototype threat spectra at a specified false positive rate using simulated annealing. The new procedure can be applied to configuring the detection algorithm when the prototype threats are many and diverse without significantly compromising the detection sensitivity to any one of them. N-SCRAD makes use of estimates of background variability obtained during a search from prior measurements of background. In applications such estimates made purely from past measurements sometimes do not extrapolate well to current conditions. In this work we present a new method for correcting those estimates to current conditions of the total count rate. We demonstrate that the correction lowers detection thresholds for a specified false positive rate, enabling greater sensitivity to targets. The two proposed improvements to N-SCRAD maximize detection power for the expected variety of possible threats while reducing or maintaining the false positive rate.

Anomaly detection, Gamma-ray spectroscopy, Radiati↗

Advanced ion beam calorimetry for the test facility ELISE

The negative ion source test facility ELISE (Extraction from a Large Ion Source Experiment) is in operation since beginning of 2013 at the Max-Planck-Institut für Plasmaphysik (IPP) in Garching bei München. The large radio frequency driven ion source of ELISE is about 1×1 m{sup 2} in size (1/2 the ITER source) and can produce a plasma for up to 1 h. Negative ions can be extracted and accelerated by an ITER-like extraction system made of 3 grids with an area of 0.1 m{sup 2}, for 10 s every 3 minutes. A total accelerating voltage of up to 60 kV is available, i.e. a maximum ion beam power of about 1.2 MW can be produced. ELISE is equipped with several beam diagnostic tools for the evaluation of the beam characteristics. In order to evaluate the beam properties with a high level of detail, a sophisticated diagnostic calorimeter has been installed in the test facility at the end of 2013, starting operation in January 2014. The diagnostic calorimeter is split into 4 copper plates with separate water calorimetry for each of the plates. Each calorimeter plate is made of 15×15 copper blocks, which act as many separate inertial calorimeters and are attached to a copper plate with an embedded cooling circuit. The block geometry and the connection with the cooling plate are optimized to accurately measure the time-averaged power of the 10 s ion beam. The surface of the blocks is covered with a black coating that allows infrared (IR) thermography which provides a 2D profile of the beam power density. In order to calibrate the IR thermography, 48 thermocouples are installed in as many blocks, arranged in two vertical and two horizontal rows. The paper describes the beam calorimetry in ELISE, including the methods used for the IR thermography, the water calorimetry and the analytical methods for beam profile evaluation. It is shown how the maximum beam inhomogeneity amounts to 13% in average. The beam divergence derived by IR thermography ranges between 1° and 4° and correlates relatively well with the values measured by beam emission spectroscopy with up to 30% difference. It has also been observed that the beam inhomogeneity decreases with lower beam divergence.

43 PARTICLE ACCELERATORS↗

Absolute Dosimetry Model of the University of Washington Clinical Neutron Therapy System (CNTS)

The University of Washington (UW) Clinical Neutron Therapy System (CNTS) generates a fast neutron beam using 50.5 MeV protons incident on a beryllium target. The CNTS is mainly used for fast neutron therapy in the treatment of cancer but is also used for radiation effects testing and the production of rare isotopes, or isotopes with a short half-life, for medical imaging and therapy. The accelerator and treatment head is modeled using the MCNP6 Monte Carlo code to enable beam characterization (neutron and photon fluence, linear energy transfer, secondary particle production), study the behavior of neutron dosimeters and ionization chamber (IC) responses, and to conduct first principle studies of the relative biological effectiveness (RBE) of fast neutrons compared to {sup 60}Co γ-rays. Measurements of neutron dose in selected CNTS fields were made using a model-17 ion chamber (IC-17) flowing methane-based, tissue-equivalent (TE) gas. As a first approximation, we compared IC-17 measurements to the MCNP calculated dose in a thin layer of water at selected locations along the central axis of the beam. To examine the impact of the composition of the chamber fill-gas and the chamber design characteristics, we also developed a high-resolution (∼ 50 μm) MCNP model of the IC-17 from a computerized tomography (CT) scan. Initial results indicate that the dose response of the IC-17 ion chamber is up to 30% larger (smaller?) compared to the dose to water for neutrons with energies >20 MeV. Differences in chamber and water response as large as 800% occur for neutrons with kinetic energies below 1 keV. The simulations of IC-17 response (and dose to water) for CNTS fast neutron spectra match measured doses within 4.6% for all field sizes and irradiation geometries considered. This reported studies provide additional evidence establishing use of the IC-17 ion chamber model or a thin layer of water as a reasonable surrogate for CNTS fast neutron dose calculations.

61 RADIATION PROTECTION AND DOSIMETRY↗

Correction of Cloud Optical Thickness Retrievals from Nadir Reflectances in the Presence of 3D Radiative Effects. Part I: Concept and Tests on 3D RT Simulations

3D effects cause substantial underestimation of cloud optical thickness (COT) in airborne and satellite retrievals based on 1D radiative transfer computations (such as in the case of widely used bispectral technique). For a single-layer isolated cloud we propose a simple linear correction of the retrieved COT with the renormalization factor dependent on the cloud’s aspect ratio (the ratio between vertical and horizontal dimensions of the cloud). This is an empirical assumption which we successfully test using synthetic 3D RT data. We introduce a heuristic “block model” of 3D radiative effects and show that the functional form of the renormalization factor is consistent with the process of radiation escape from cloud sides in an essentially 3D geometry. We also extend the block model to the case of single-layer broken cloud field with radiative interaction between the neighboring clouds. In this case the renormalization factor depends also on the distance between clouds.

cloud optical thickness↗

Validating a Model for Welding Induced Residual Stress Using High-Energy X-ray Diffraction

Integrated computational materials engineering (ICME) provides a pathway to advance performance in structures through the use of physically-based models to better understand how manufacturing processes influence product performance. As one particular challenge, consider that residual stresses induced in fabrication are pervasive and directly impact the life of structures. For ICME to be an effective strategy, it is essential that predictive capability be developed in conjunction with critical experiments. In the present paper, simulation results from a multi-physics model for gas metal arc welding are evaluated through x-ray diffraction using synchrotron radiation. A test component was designed with intent to develop significant gradients in residual stress, be representative of real-world engineering application, yet remain tractable for finely spaced strain measurements with positioning equipment available at synchrotron facilities. Finally, the experimental validation lends confidence to model predictions, facilitating the explicit consideration of residual stress distribution in prediction of fatigue life.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Identification of ATIC as a Novel Target for Chemoradiosensitization

Mutations in the gene encoding 5-aminoimidazole-4-carboxamide ribonucleotide formyltransferase/IMP cyclohydrolase (ATIC), a bifunctional enzyme that catalyzes the final 2 steps of the purine de novo biosynthetic pathway, were identified in a subject referred for radiation sensitivity testing. Functional studies were performed to determine whether ATIC inhibition was radiosensitizing and, if so, to elucidate the mechanism of this effect and determine whether small molecule inhibitors of ATIC could act as effective radiosensitizing agents.

62 RADIOLOGY AND NUCLEAR MEDICINE↗