Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “plan”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 847 records · Page 47

Generative large language models for predictive maintenance planning

Maintenance planning and the generation of necessary components for tasks can prove time-consuming and complex. Automating the creation of recurring or similar tasks by leveraging previous planning packages and data, while uncovering insights to automate planning package generation, presents an opportunity to conserve valuable time and resources. This work aims to harness the textual and probabilistic capabilities of large language models (LLMs) to automate the generation of planning packages. Utilizing diverse data sources ranging from raw data to handwritten text, both singular and collaborative LLMs are trained and tested. Results demonstrate their capability to generate essential planning package components, effectively replicating the statistical patterns in the data. This demonstrates the use of these tools inside a digital asset for automated planning. This work outlines a methodology for constructing datasets, a training suite, and evaluation methods for LLM-based textual and conversational planning tools utilized in an asset digital twin. Results indicate that the fine-tuned models generate estimated planning information within the statistical ranges observed in real maintenance data. The models achieve high accuracy (>90%) in document question-answering and instruction generation tasks. Furthermore, the conversational retrieval-augmented generation (RAG) assistant system achieves 100% document retrieval accuracy, while conversational information capture exceeds 98% across the majority of work-package assistant modules.

97 MATHEMATICS AND COMPUTING↗

Incorporate Imaging Characteristics Into an Arteriovenous Malformation Radiosurgery Plan Evaluation Model

Purpose: To integrate imaging performance characteristics, specifically sensitivity and specificity, of magnetic resonance angiography (MRA) and digital subtraction angiography (DSA) into arteriovenous malformation (AVM) radiosurgery planning and evaluation. Methods and Materials: Images of 10 patients with AVMs located in critical brain areas were analyzed in this retrospective planning study. The image findings were first used to estimate the sensitivity and specificity of MRA and DSA. Instead of accepting the imaging observation as a binary (yes or no) mapping of AVM location, our alternative is to translate the image into an AVM probability distribution map by incorporating imagers' sensitivity and specificity, and to use this map as a basis for planning and evaluation. Three sets of radiosurgery plans, targeting the MRA and DSA positive overlap, MRA positive, and DSA positive were optimized for best conformality. The AVM obliteration rate (ORAVM) and brain complication rate served as endpoints for plan comparison. Results: In our 10-patient study, the specificities and sensitivities of MRA and DSA were estimated to be (0.95, 0.74) and (0.71, 0.95), respectively. The positive overlap of MRA and DSA accounted for 67.8% {+-} 4.9% of the estimated true AVM volume. Compared with plans targeting MRA and DSA-positive overlap, plans targeting MRA-positive or DSA-positive improved ORAVM by 4.1% {+-} 1.9% and 15.7% {+-} 8.3%, while also increasing the complication rate by 1.0% {+-} 0.8% and 4.4% {+-} 2.3%, respectively. Conclusions: The impact of imagers' quality should be quantified and incorporated in AVM radiosurgery planning and evaluation to facilitate clinical decision making.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Dosimetric Comparison of 3-Dimensional Planning Techniques Using an Intravaginal Multichannel Balloon Applicator for High-Dose-Rate Gynecologic Brachytherapy

Purpose: To study the dosimetric differences of various channel combinations of the Capri vaginal applicator. Methods and Materials: The Capri consists of a single central channel (R1), an inner array of 6 channels (R2), and an outer array of 6 channels (R3). Three-dimensional plans were simulated for 6 channel arrangements (R1, R2, R12, R13, R23, and R123). Treatment plans were optimized to the applicator surface or 5-mm depth while minimizing dose to organs at risk (OARs: bladder, rectum, sigmoid, and urethra). The clinical target volume (CTV) was defined as a 5-mm circumferential shell extending 4 cm in length around the applicator. Clinical target volume coverage (D{sub mean}, D{sub 90}, V{sub 100}, and V{sub 150}) and OAR doses (D{sub 0.1} {sub cm{sup 3}}, D{sub 1} {sub cm{sup 3}}, D{sub 2} {sub cm{sup 3}}, and D{sub mean}) were compared. A comparison between the Capri (R123) and a conventional single-channel applicator was also done. Statistical significance (P value <.05) was evaluated with a 2-tailed t test. Results: When prescribing to 5-mm depth, CTV coverage using all 13 channels (R123) versus a single channel (R1) was similar; however, when prescribing to the surface there were differences (P<.0001) in all CTV metrics except for the V{sub 150}. The R1 plans had higher doses to all OARs compared with R123 plans (P<.007). Doses to OARs were not significantly different between R23 and R123 plans (P=.05-.95), and CTV coverage differences were on the order of 1%. Capri R123 plans provided slightly lower CTV D{sub 90} and D{sub mean} but equivalent OAR doses with smaller standard deviations compared with conventional cylinder plans for both prescriptions. Conclusions: The Capri multichannel applicator provides equivalent target coverage at 5-mm depth, with significantly reduced dose to OARs relative to using a single channel. Optimal plans can be achieved using R12 (lowest V{sub 150}) or R123 or R23 (lowest OAR doses)

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Head and Neck Margin Reduction With Adaptive Radiation Therapy: Robustness of Treatment Plans Against Anatomy Changes

Purpose: We set out to investigate loss of target coverage from anatomy changes in head and neck cancer patients as a function of applied safety margins and to verify a cone beam computed tomography (CBCT)–based adaptive strategy with an average patient anatomy to overcome possible target underdosage. Methods and Materials: For 19 oropharyngeal cancer patients, volumetric modulated arc therapy treatment plans (2 arcs; simultaneous integrated boost, 70 and 54.25 Gy; 35 fractions) were automatically optimized with uniform clinical target volume (CTV)–to–planning target volume margins of 5, 3, and 0 mm. We applied b-spline CBCT–to–computed tomography (CT) deformable registration to allow recalculation of the dose on modified CT scans (planning CT deformed to daily CBCT following online positioning) and dose accumulation in the planning CT scan. Patients with deviations in primary or elective CTV coverage >2 Gy were identified as candidates for adaptive replanning. For these patients, a single adaptive intervention was simulated with an average anatomy from the first 10 fractions. Results: Margin reduction from 5 mm to 3 mm to 0 mm generally led to an organ-at-risk (OAR) mean dose (D{sub mean}) sparing of approximately 1 Gy/mm. CTV shrinkage was mainly seen in the elective volumes (up to 10%), likely related to weight loss. Despite online repositioning, substantial systematic errors were present (>3 mm) in lymph node CTV, the parotid glands, and the larynx. Nevertheless, the average increase in OAR dose was small: maximum of 1.2 Gy (parotid glands, D{sub mean}) for all applied margins. Loss of CTV coverage >2 Gy was found in 1, 3, and 7 of 73 CTVs, respectively. Adaptive intervention in 0-mm plans substantially improved coverage: in 5 of 7 CTVs (in 6 patients) to <2 Gy of initially planned. Conclusions: Volumetric modulated arc therapy head and neck cancer treatment plans with 5-mm margins are robust for anatomy changes and show a modest increase in OAR dose. Margin reduction improves OAR sparing with approximately 1 Gy/mm at the expense of target coverage in a subgroup of patients. Patients at risk of CTV underdosage >2 Gy in 0-mm plans may be identified early in treatment using dose accumulation. A single intervention with an average anatomy derived from CBCT effectively mitigates discrepancies.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

IMRT vs. 3D Noncoplanar Treatment Plans for Maxillary Sinus Tumors: A New Tool for Quantitative Evaluation

We compared 9-field, equispaced intensity modulated radiation therapy (IMRT), 4- to 5-field, directionally optimized IMRT, and 3-dimensional (3D) noncoplanar planning approaches for tumors of the maxillary sinus. Ten patients were planned retrospectively to compare the different treatment techniques. Prescription doses were 60 to 70 Gy. Critical structures contoured included optic nerves and chiasm, lacrimal glands, lenses, and retinas. As an aid for plan assessment, we introduced a new tool: Critical Organ Scoring Index (COSI), which allows quantitative evaluation of the tradeoffs between target coverage and critical organ sparing. This index was compared with other, commonly used conformity indices. For a reliable assessment of both tumor coverage and dose to critical organs in the different planning techniques, we introduced a 2D, graphical representation of COSI vs. conformity index (CI). Dose-volume histograms and mean, maximum, and minimum organ doses were also compared. IMRT plans delivered lower doses to ipsilateral structures, but were unable to spare them. 3D plans delivered less dose to contralateral structures, and were more homogeneous, as well. Both IMRT approaches gave similar results. In cases where choice of optimal plan was difficult, the novel 2D COSI-CI representation gave an accurate picture of the tradeoffs between target coverage and organ sparing, even in cases where other conformity indices failed. Due to their unique anatomy, maxillary sinus tumors may benefit more from a noncoplanar approach than from IMRT. The new graphical representation proposed is a quick, visual, reliable tool, which may facilitate the physician's choice of best treatment plan for a given patient.

61 RADIATION PROTECTION AND DOSIMETRY↗

Dosimetric Comparison of Helical Tomotherapy and Linac-IMRT Treatment Plans for Head and Neck Cancer Patients

The rapid development and clinical implementation of external beam radiation treatment technologies continues. The existence of various commercially available technologies for intensity-modulated radiation therapy (IMRT) has stimulated interest in exploring the differential potential advantage one may have compared with another. Two such technologies, Hi-Art Helical Tomotherapy (HT) and conventional medical linear accelerator-based IMRT (LIMRT) have been shown to be particularly suitable for the treatment of head and neck cancers. In this study, 23 patients who were diagnosed with stages 3 or 4 head and neck cancers, without evidence of distance metastatic disease, were treated in our clinic. Treatment plans were developed for all patients simultaneously on the HT planning station and on the Pinnacle treatment planning system for step-and-shoot IMRT. Patients were treated only on the HT unit, with the LIMRT plan serving as a backup in case the HT system might not be available. All plans were approved for clinical use by a physician. The prescription was that patients receive at least 95% of the planning target volume (PTV), which is 66 Gy at 2.2 Gy per fraction. Several dosimetric parameters were computed: PTV dose coverage; PTV volume conformity index; the normalized total dose (NTD), where doses were converted to 2 Gy per fraction to organs at risk (OAR); and PTV dose homogeneity. Both planning systems satisfied our clinic's PTV prescription requirements. The results suggest that HT plans had, in general, slightly better dosimetric characteristics, especially regarding PTV dose homogeneity and normal tissue sparing. However, for both techniques, doses to OAR were well below the currently accepted normal tissue tolerances. Consequently, factors other than the dosimetric parameters studied here may have to be considered when making a choice between IMRT techniques.

61 RADIATION PROTECTION AND DOSIMETRY↗

A Comparison of Clinical and Dosimetric Outcomes in Patients Receiving Partial Breast Irradiation with Photon-Only versus Mixed Photon/Electron Treatment Plans

Several series evaluating external-beam partial breast irradiation (PBI) have linked negative cosmetic outcomes to large normal tissue treatment volumes. We compared patients treated with PBI whose treatment plans included only photons to those whose plans incorporated electrons. Twenty-seven patients were identified: median age 67 years, pT1 82%, pN0 56%, margin negative 100%. All received 38.5 Gy using 3-5 noncoplanar photon beams (6-15X). Electrons (9-20 MeV) were included in 59%. Median follow-up was 22 months. Ninety percent experienced good/excellent cosmetic outcomes. Two patients had fair cosmesis, and both were treated with a mixed photon/electron approach. Median conformity index for photon-only treatment plans was 1.7 (range, 0.9-2.0) and for photon/electron plans, 1.0 (0.3-1.4). Median percent ipsilateral breast volume receiving 100% and 50% of prescription dose was 19 and 50 for photon-only plans vs. 10 and 38 for photon/electron plans (p < 0.05). Median percent target volume receiving 100% and 95% of prescription dose was 93 and 98 for photon-only plans vs. 75 and 94 for photon/electron plans (p < 0.05). A mixed photon/electron, noncoplanar technique decreases the volume of treated normal breast tissue at the cost of slightly decreased tumor bed coverage. Further study is needed to determine whether this results in a more favorable therapeutic ratio than photon-only approaches.

61 RADIATION PROTECTION AND DOSIMETRY↗

A multicriteria framework with voxel-dependent parameters for radiotherapy treatment plan optimization

Purpose: To establish a new mathematical framework for radiotherapy treatment optimization with voxel-dependent optimization parameters. Methods: In the treatment plan optimization problem for radiotherapy, a clinically acceptable plan is usually generated by an optimization process with weighting factors or reference doses adjusted for a set of the objective functions associated to the organs. Recent discoveries indicate that adjusting parameters associated with each voxel may lead to better plan quality. However, it is still unclear regarding the mathematical reasons behind it. Furthermore, questions about the objective function selection and parameter adjustment to assure Pareto optimality as well as the relationship between the optimal solutions obtained from the organ-based and voxel-based models remain unanswered. To answer these questions, the authors establish in this work a new mathematical framework equipped with two theorems. Results: The new framework clarifies the different consequences of adjusting organ-dependent and voxel-dependent parameters for the treatment plan optimization of radiation therapy, as well as the impact of using different objective functions on plan qualities and Pareto surfaces. The main discoveries are threefold: (1) While in the organ-based model the selection of the objective function has an impact on the quality of the optimized plans, this is no longer an issue for the voxel-based model since the Pareto surface is independent of the objective function selection and the entire Pareto surface could be generated as long as the objective function satisfies certain mathematical conditions; (2) All Pareto solutions generated by the organ-based model with different objective functions are parts of a unique Pareto surface generated by the voxel-based model with any appropriate objective function; (3) A much larger Pareto surface is explored by adjusting voxel-dependent parameters than by adjusting organ-dependent parameters, possibly allowing for the generation of plans with better trade-offs among different clinical objectives. Conclusions: The authors have developed a mathematical framework for radiotherapy treatment optimization using voxel-based parameters. The authors can improve the plan quality by adjusting voxel-based weighting factors and exploring the unique and large Pareto surface which include all the Pareto surfaces that can be generated by organ-based model using different objective functions.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-E-T-131: Dosimetric Impact and Evaluation of Different Heterogenity Algorithm in Volumetric Modulated Arc Therapy Plan for Stereotactic Ablative Radiotherapy Lung Treatment with the Flattening Filter Free Beam

Purpose: The present study aimed to investigate the dosimetric impacts of the anisotropic analytic algorithm (AAA) and the Acuros XB (AXB) plan for lung stereotactic ablative radiation therapy using flattening filter-free (FFF) beam. We retrospectively analyzed 10 patients. Methods: We retrospectively analyzed 10 patients. The dosimetric parameters for the target and organs at risk (OARs) from the treatment plans calculated with these dose calculation algorithms were compared. The technical parameters, such as the computation times and the total monitor units (MUs), were also evaluated. Results: A comparison of DVHs from AXB and AAA showed that the AXB plan produced a high maximum PTV dose by average 4.40% with a statistical significance but slightly lower mean PTV dose by average 5.20% compared to the AAA plans. The maximum dose to the lung was slightly higher in the AXB compared to the AAA. For both algorithms, the values of V5, V10 and V20 for ipsilateral lung were higher in the AXB plan more than those of AAA. However, these parameters for contralateral lung were comparable. The differences of maximum dose for the spinal cord and heart were also small. The computation time of AXB was found fast with the relative difference of 13.7% than those of AAA. The average of monitor units (MUs) for all patients was higher in AXB plans than in the AAA plans. These results indicated that the difference between AXB and AAA are large in heterogeneous region with low density. Conclusion: The AXB provided the advantages such as the accuracy of calculations and the reduction of the computation time in lung stereotactic ablative radiotherapy (SABR) with using FFF beam, especially for VMAT planning. In dose calculation with the media of different density, therefore, the careful attention should be taken regarding the impacts of different heterogeneity correction algorithms. The authors report no conflicts of interest.

60 APPLIED LIFE SCIENCES↗

SU-E-T-148: Efficient Verification Method for Modulated Electron Radiotherapy Treatment Plans

Purpose: For shallow tumors, modulated electron radiotherapy (MERT) promises a reduction of dose to distal organs at risk. At our institution a framework was developed in order to create treatment plans for MERT employing both forward and inverse optimization. In this work, an efficient quality assurance (QA) process is established. Methods: Treatment plans for three different tumor sites were created using an inverse optimization. These plans consist of 6–12 segments and energies between 6 and 18 MeV. An already established QA process for photon IMRT plans is now extended to additionally handle MERT plans. First, the dose distributions are calculated in a homogenous water phantom. For this task a dedicated Monte Carlo (MC) framework for MERT is used. Second, the segments are applied on a stand-alone amorphous silicon electronic portal imaging device (EPID) using a source-to-surface distance of 70 cm. This device was calibrated for electron beams in a previous work. An in-house developed analysis software, is then utilized for comparisons and evaluation of the measured and calculated dose distributions. Results: For all three plans the calculated dose distributions agree well with the measured ones. Using a 2D gamma comparison (2% of dose max/2 mm and 10% dose threshold) passing rates >98% are achieved.The dose calculation for each plan on the water phantom, using voxels of 0.2×0.2×0.2 cm{sup 3}, takes at maximum 30 min on a single core Pentium 2.66 GHz system with 6 GB RAM, to reach a statistical uncertainty of 2% (1 std. dev.). Conclusion: An already established QA procedure for IMRT photon plans was applied for MERT. The dedicated MC framework and the use of EPID measurements allow an efficient QA procedure in a clinical environment. This work was supported by Varian Medical Systems.

60 APPLIED LIFE SCIENCES↗

SU-E-T-489: Plan Comparisons of Re-Irradiation Treatment of Three Intensity Modulated Techniques

Purpose: There have been controversial reports on the comparison of dosimetric quality of TomoTherapy (Tomo), VMAT and IMRT. One of the main reasons is the sampled cases are often not dosimetrically challenging enough to test the limit of optimization/delivery modalities. We chose difficult re-irradiation cases when certain organ at risk (OAR) requires extremely low dose to examine the ability of OAR sparing of three main intensity modulated techniques. Methods: Three previous treated patients with disease site on head and neck (HN), brain and lung are planned for reirradiation treatment. The Tomo planning used jaw 2.5cm and pitch 0.3. VMAT and IMRT were planned on Pinnacle for a Varian 21iX Linac with MLC leaf width 5mm. VMAT plan used 2 Arcs and IMRT plan had beams 11–13. The dosimetric endpoints and treatment time were compared for each technique of each patient. Results: Plans of three techniques cover PTV similarly. The HN case requires PTV dose 60Gy but to limit dose of cord which is 8mm away <12Gy. The cord dose of Tomo, VMAT and IMRT plan is 11.6Gy, 11.3Gy and 11.0Gy, respectively. The brain case has PTV prescription 50.4 Gy while requiring the dose of brainstem < 28Gy. Tomo, VMAT and IMRT plan generate brainstem dose 27.6Gy, 27.6Gy and 27.1Gy respectively. For the lung case, PTV was prescribed 42.5Gy but cord dose constraint was 22.5Gy. The cord dose is optimized to 22.3Gy, 20.8Gy and 21.4Gy by Tomo, VMAT and IMRT, respectively. The delivery time if normalized to Tomo is 47.0%/145.6% (VMAT/IMRT), 33.3%/106.3% and 74.1%/245.4% for HN, brain and lung case, respectively. Conclusion: Difficult re-irradiation cases were used to test the limit of three intensity modulated techniques. Tomo, VMAT and IMRT show similar dosimetry while VMAT is the most efficient one and IMRT is the least.

60 APPLIED LIFE SCIENCES↗

SU-E-T-504: Usefulness of CT-MR Fusion in Radiotherapy Planning for Prostate Cancer Patient with Bilateral Hip Replacements

Purpose: Target localization of prostate for Intensity Modulated Radiation Therapy (IMRT) in patients with bilateral hip replacements is difficult due to artifacts in Computed Tomography (CT) images generated from the prostheses high Z materials. In this study, Magnetic Resonance (MR) images fused with CT images are tested as a solution. Methods: CT images of 2.5 mm slice thickness were acquired on a GE Lightspeed scanner with a flat-topped couch for a prostate cancer patient with bilateral hip replacements. T2 weighted images of 5 mm separation were acquired on a MR Scanner. After the MR-CT registration on a radiotherapy treatment planning system (Eclipse, Varian), the target volumes were defined by the radiation oncologists on MR images and then transferred to CT images for planning and dose calculation. The CT Hounsfield Units (HU) was reassigned to zero (as water) for artifacts. The Varian flat panel treatment couch was modeled for dose calculation accuracy with heterogeneity correction. A Volume Matrix Arc Therapy (VMAT) and a seven-field IMRT plans were generated, each avoiding any beam transversing the prostheses; the two plans were compared. The superior VMAT plan was used for treating the patient. In-vivo dosimetry was performed using MOSFET (Best Canada) placed in a surgical tube inserted into the patient rectum during therapy. The measured dose was compared with planned dose for MOSFET location. Results: The registration of MR-CT images and the agreement of target volumes were confirmed by three physicians. VMAT plan was deemed superior to IMRT based on dose to critical nearby structures and overall conformality of target dosing. In-vivo measured dose compared with calculated dose was -4.5% which was likely due to attenuation of the surgical tube surrounding MOSFET. Conclusion: When artifacts are present on planning CT due to bilateral hip prostheses, MR-CT image fusion is a feasible solution for target delineation.

60 APPLIED LIFE SCIENCES↗

SU-E-T-546: Use of Implant Volume for Quality Assurance of Low Dose Rate Brachytherapy Treatment Plans

Purpose: To analyze the application of volume implant (V100) data as a method for a global check of low dose rate (LDR) brachytherapy plans. Methods: Treatment plans for 335 consecutive patients undergoing permanent seed implants for prostate cancer and for 113 patients treated with plaque therapy for ocular melanoma were analyzed. Plaques used were 54 COMS (10 to 20 mm, notched and regular) and 59 Eye Physics EP917s with variable loading. Plots of treatment time x implanted activity per unit dose versus v100 ^.667 were made. V100 values were obtained using dose volume histograms calculated by the treatment planning systems (Variseed 8.02 and Plaque Simulator 5.4). Four different physicists were involved in planning the prostate seed cases; two physicists for the eye plaques. Results: Since the time and dose for the prostate cases did not vary, a plot of implanted activity vs V100 ^.667 was made. A linear fit with no intercept had an r{sup 2} = 0.978; more than 94% of the actual activities fell within 5% of the activities calculated from the linear fit. The greatest deviations were in cases where the implant volumes were large (> 100 cc). Both COMS and EP917 plaque linear fits were good (r{sup 2} = .967 and .957); the largest deviations were seen for large volumes. Conclusions: The method outlined here is effective for checking planning consistency and quality assurance of two types of LDR brachytherapy treatment plans (temporary and permanent). A spreadsheet for the calculations enables a quick check of the plan in situations were time is short (e.g. OR-based prostate planning)

07 ISOTOPE AND RADIATION SOURCES↗

SU-E-T-632: A Dosimetric Comparison of the 3D-CRT Planning of Chest Wall in Post-Mastectomy Breast Cancer Patients, with and Without Breast Board Setup

Purpose: Breast boards are used in breast radiation which increases normal lung and heart doses, when supraclavicular field is included. Therefore, in this study through dose volume histogram (DVHs), lung and heart doses comparison was done between two different setups i.e. with and without breast board, for the treatment of left chest wall and supraclavicular fossa in postmastectomy left breast cancer. Methods: In this study, CT-Simulation scans of ten breast cancer patients were done with and without breast board, at Shifa International Hospitals Islamabad, to investigate the differences between the two different setups of the irradiation of left chest wall in terms of lung and heart doses. For immobilization, support under the neck, shoulders and arms was used. Precise PLAN 2.15 treatment planning system (TPS) was used for 3D-CRT planning. The total prescribed dose for both the plans was 5000 cGy/25 fractions. The chest wall was treated with a pair of tangential photon fields and the upper supraclavicular nodal regions were treated with an anterior photon field. A mono-isocentric technique was used to match the tangential fields with the anterior field at the isocentre. The dose volume histogram was used to compare the doses of heart and ipsilateral lung. Results: Both the plans of each patient were generated and compared. DVH results showed that for the same PTV dose coverage, plans without breast board resulted in a reduction of lung and heart doses compared with the plans with breast board. There was significant reductions in V20, V<25 and mean doses for lung and V<9 and mean doses for heart. Conclusion: In comparison of both the plans, setup without breast board significantly reduced the dose-volume of the ipsilateral lung and heart in left chest wall patients. Waived registration request has been submitted.

60 APPLIED LIFE SCIENCES↗

TU-C-BRE-07: Quantifying the Clinical Impact of VMAT Delivery Errors Relative to Prior Patients’ Plans and Adjusted for Anatomical Differences

Purpose: There is increased interest in the Radiation Oncology Physics community regarding sensitivity of pre-treatment IMRT/VMAT QA to delivery errors. Consequently, tools mapping pre-treatment QA to the patient DVH have been developed. However, the quantity of plan degradation that is acceptable remains uncertain. Using DVHs adapted from prior patients’ plans, we developed a technique to determine the magnitude of various delivery errors required to degrade a treatment plan to outside the clinically accepted range. Methods: DVHs for relevant organs at risk were adapted from a population of prior patients’ plans using a machine learning algorithm to establish the clinically acceptable DVH range specific to the patient’s anatomy. We applied this technique to six low-risk prostate cancer patients treated with single-arc VMAT and compared error-induced DVH changes to the adapted DVHs to determine the magnitude of error required to push the plan outside of the acceptable range. The procedure follows: (1) Errors (systematic ' random shift of MLCs, gantry-MLC desynchronization, dose rate fluctuations, etc.) were simulated and degraded DVHs calculated using the Varian Eclipse TPS. (2) Adapted DVHs and acceptable ranges for DVHs were established. (3) Relevant dosimetric indices and corresponding acceptable ranges were calculated from the DVHs. Key indices included NTCP (Lyman-Kutcher-Burman Model) and QUANTEC’s dose-volume Objectives: s of V75Gy≤0.15 for the rectum and V75Gy≤0.25 for the bladder. Results: Degradations to the clinical plan became “unacceptable” for 19±29mm and 1.9±2.0mm systematic outward shifts of a single leaf and leaf bank, respectively. All other simulated errors fell within the acceptable range. Conclusion: Utilizing machine learning and prior patients’ plans one can predict a clinically acceptable range of DVH degradation for a specific patient. Comparing error-induced DVH degradations to this range, it is shown that single-arc VMAT plans for low-risk prostate are relatively insensitive to many potential delivery errors.

60 APPLIED LIFE SCIENCES↗

SU-E-J-244: Development and Validation of a Knowledge Based Planning Model for External Beam Radiation Therapy of Locally Advanced Non-Small Cell Lung Cancer

Purpose: The study aims to develop and validate a knowledge based planning (KBP) model for external beam radiation therapy of locally advanced non-small cell lung cancer (LA-NSCLC). Methods: RapidPlan™ technology was used to develop a lung KBP model. Plans from 65 patients with LA-NSCLC were used to train the model. 25 patients were treated with VMAT, and the other patients were treated with IMRT. Organs-at-risk (OARs) included right lung, left lung, heart, esophagus, and spinal cord. DVH and geometric distribution DVH were extracted from the treated plans. The model was trained using principal component analysis and step-wise multiple regression. Box plot and regression plot tools were used to identify geometric outliers and dosimetry outliers and help fine-tune the model. The validation was performed by (a) comparing predicted DVH boundaries to actual DVHs of 63 patients and (b) using an independent set of treatment planning data. Results: 63 out of 65 plans were included in the final KBP model with PTV volume ranging from 102.5cc to 1450.2cc. Total treatment dose prescription varied from 50Gy to 70Gy based on institutional guidelines. One patient was excluded due to geometric outlier where 2.18cc of spinal cord was included in PTV. The other patient was excluded due to dosimetric outlier where the dose sparing to spinal cord was heavily enforced in the clinical plan. Target volume, OAR volume, OAR overlap volume percentage to target, and OAR out-of-field volume were included in the trained model. Lungs and heart had two principal component scores of GEDVH, whereas spinal cord and esophagus had three in the final model. Predicted DVH band (mean ±1 standard deviation) represented 66.2±3.6% of all DVHs. Conclusion: A KBP model was developed and validated for radiotherapy of LA-NSCLC in a commercial treatment planning system. The clinical implementation may improve the consistency of IMRT/VMAT planning.

60 APPLIED LIFE SCIENCES↗

SU-E-T-130: Are Proton Gantries Needed? An Analysis of 4332 Patient Proton Gantry Treatment Plans From the Past 10 Years

Purpose: To ascertain the necessity of a proton gantry, as compared to the feasibility of using a horizontal fixed proton beam-line for treatment with advanced technology. Methods: To calculate the percentage of patients that can be treated with a horizontal fixed beam-line instead of a gantry, we analyze the distributions of beam orientations of our proton gantry patients treated over the past 10 years. We identify three horizontal fixed beam geometries (FIXED, BEND and MOVE) with the patient in lying and/or sitting positions. The FIXED geometry includes only table/chair rotations and translations. In BEND, the beam can be bent up/down for up to 20 degrees. MOVE allows for patient head/body angle adjustment. Based on the analysis, we select eight patients whose plan involves beams which are still challenging to achieve with a horizontal fixed beam. These beams are removed in the pencil beam scanning (PBS) plan optimized for the fixed beam-line (PBS-fix). We generate non-coplanar PBS-gantry plans for comparison, and perform a robustness analysis. Results: The percentage of patients with head-and-neck/brain tumors that can be treated with horizontal fixed beam is 44% in FIXED, 70% in 20-degrees BEND, and 100% in 90-degrees MOVE. For torso regions, 99% of the patients can be treated in 20-degree BEND. The target coverage is more homogeneous with PBS-fix plans compared to the clinical scattering treatment plans. The PBS-fix plans reduce the mean dose to organs-at-risk by a factor of 1.1–28.5. PBS-gantry plans are as good as PBS-fix plans, sometimes marginally better. Conclusion: The majority of the beam orientations can be realized with a horizontal fixed beam-line. Challenging non-coplanar beams can be eliminated with PBS delivery. Clinical implementation of the proposed fixed beam-line requires use of robotic patient positioning, further developments in immobilization, and image guidance. However, our results suggest that fixed beam-lines can be as effective as gantries.

60 APPLIED LIFE SCIENCES↗

SU-E-T-493: Influence of Filtered and Flatting Filter Free Photon Beam of 10 Megavolts Energy On Rapid Arc Radiotherapy Planning for Cervix Carcinoma

Purpose: Aim of this study is to determine the dosimetric influence of Filtered and Flatting Filter Free Photon Beam of 10 MV energy on RA planning for Ca. Cervix. Methods: CT data sets of eleven patients reported with carcinoma cervix were used for RA planning for 10MV -FFB and 10MV-FFFB. RA plans were generated using two full arcs.All RA plans were generated to deliver a dose of 50.4Gy in 28 fractions for PTV and ALARA for OAR’s. All plans were analysed for PTV Coverage, conformity Index, homogeneity index, dose to OAR’s, integral dose to normal tissue and total monitor units were studied. Results: DVH was used to evaluate RA plans for both 10MV-FFB and 10MV-FFFB photon beam. Planning results show a comparable PTV coverage for both energies. Results shows volume of PTV receiving prescription dose were 95.10+ 0.09% and 95.09 +0.11%, and volume of PTV receiving a dose of 107% is 0.45+0.96% and 5.25+8.9%, homogeneity index (HI) were 1.051+0.007 and 1.066+0.008, Conformity Index(CI) were 1.003+0.019 and 1.012+0.013, Mean Integral dose were 2.65+0.34 and 2.60+0.33(*10−5Gy.cm3) for 10MV-FFB and 10MV-FFFB respectively. 10MV-FB shows statistically significant (p<0.05) improvement in mean doses to bladder, rectum, bowel and mean total number of MU’s and also shows remarkable decrease in mean total no. of MU’s by 43.7% in comparison to 10MV-FFFB. There is statistically significant (p<0.05) difference found in CI and HI for 10MV-FB in comparison to 10MV -FFF beam. 10MV-FFFB shows statistically significant (p<0.05) for mean NTID and delivers 1.65 % less NTID in comparison to 10 MV- FB. Conclusion: 10MV-FB is superior to 10MV-FFFB for rapid arc planning in case of Cervix carcinomas, it offers better target coverage and OAR’s sparing, comparable mean Integral dose to normal tissues and 10 MV- FB also produced highly conformal and homogeneous dose distribution in comparison to 10MV-FFFB.

60 APPLIED LIFE SCIENCES↗