Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “permitting”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 847 records · Page 47

FAST $\mathrm{G}$ AP $\mathrm{F}$ ILL : efficient gap filling in metabolic networks

Genome-scale metabolic reconstructions summarize current knowledge about a target organism in a structured manner and as such highlight missing information. Such gaps can be filled algorithmically. Scalability limitations of available algorithms for gap filling hinder their application to compartmentalized reconstructions. We present fastGapFill, a computationally efficient tractable extension to the COBRA toolbox that permits the identification of candidate missing knowledge from a universal biochemical reaction database (e.g. Kyoto Encyclopedia of Genes and Genomes) for a given (compartmentalized) metabolic reconstruction. The stoichiometric consistency of the universal reaction database and of the metabolic reconstruction can be tested for permitting the computation of biologically more relevant solutions. We demonstrate the efficiency and scalability of fastGapFill on a range of metabolic reconstructions.

59 BASIC BIOLOGICAL SCIENCES↗

The Physical and Engineering Limits of Coupled In situ TEM Experiments

Almost all future energy systems (advanced nuclear reactors, fusion energy system, concentrating solar-thermal power (CSP), and wind technologies) are limited by degradation of key material systems exposed to multiple environmental stressors. The degradation during exposure to high temperatures, radiation, mechanical loading, and chemical attack is often dictated by mechanisms active at the microstructural level. The nature of these mechanisms and the associated variations between sequential and concurrent interplay can be explored if the transmission electron microscope (TEM) is utilized as a toolbox for exploration [1]. One such tool developed at Sandia National Laboratories to couple several of these environments is the In situ Ion Irradiation TEM (I3TEM) [2]. Several studies over the last decade utilizing this tool have shown that the scientific intuition developed over decades of sequential experiments is not always a good indicator of concurrent mechanisms or failure routes. This presentation will highlight the recent and planned additions into the I3TEM facility of a Waviks gas injection system and Raman system, respectively, as can be seen in Fig. 1, permitting environmental degradation from gas species leaked into the pole piece region during quantitative mechanical loading (indentation, monotonic loading, high temperature creep, irradiation induced creep, and high-cycle fatigue); multi-beam ion irradiation (energies ranging from 1 keV to 48 MeV and species from H to Au); laser exposure (20 W and 1064 nm), or various combinations thereof that are already possible [3]. This addition permits the facility to explore both sequential or concurrently the four axes of stressors: thermal, mechanical, radiation, and chemical. This information can be directly coupled to modeling, expediting the refinement and validation of both atomistic and mesoscale models.

degradation↗

Shedding far-ultraviolet light on the donor star and evolutionary state of the neutron-star LMXB Swift J1858.6−0814

ABSTRACT The evolution of accreting X-ray binary systems is closely coupled to the properties of their donor stars. Consequently, we can constrain the evolutionary track a system is by establishing the nature of its donor. Here, we present far-ultraviolet (far-UV) spectroscopy of the transient neutron-star low-mass X-ray binary J1858 in different accretion states (low-hard, high-hard, and soft). All of these spectra exhibit anomalous N v, C iv, Si iv, and He ii lines, suggesting that its donor star has undergone CNO processing. We also determine the donor’s effective temperature, Td ≃ 5700 K, and radius, Rd ≃ 1.7 R⊙, based on photometric observations obtained during quiescence. Lastly, we leverage the transient nature of the system to set an upper limit of $\dot{M}_{\rm acc} \lesssim 10^{-8.5}~{\rm M}_{\odot }~\mathrm{ yr}^{-1}$ on the present-day mass-transfer rate. Combining these with the orbital period of the system, Porb = 21.3 h, we search for viable evolution paths. The initial donor masses in the allowed solutions span the range 1 M⊙ ≲ Md,i ≲ 3.5 M⊙. All but the lowest masses in this range are consistent with the strong CNO-processing signature in the UV line ratios. The present-day donor mass in the permitted tracks are 0.5 M⊙ ≲ Md,obs ≲ 1.3 M⊙, higher than suggested by eclipse modelling. Since Porb is close to the so-called bifurcation period, both converging and diverging binary tracks are permitted. If the former is confirmed, J1858 will end its life as an ultracompact system with a substellar donor.

Castro Segura, N. (ORCID:0000000258700443)↗

Location Modification Factors for Potential Dose Estimation

A Department of Energy facility must comply with the National Emission Standard for Hazardous Air Pollutants for radioactive air emissions. The standard is an effective dose of less than 0.1 mSv yr-1 to the maximum public receptor. Additionally, a lower dose level may be assigned to a specific emission point in a State issued permit. A method to efficiently estimate the expected dose for future emissions is described. This method is most appropriately applied to a research facility with several emission points with generally low emission levels of numerous isotopes.

Radiation, radionuclide NESHAPs, Dose, 40CFR61 Sub↗

Independence of the spin current from the Néel vector orientation in antiferromagnet CoO

Spin pumping from ferromagnetic Fe into antiferromagnetic CoO across a Ag spacer layer was studied using ferromagnetic resonance (FMR) in Py/CoO/Ag/Fe/Ag(001). The thin Py film on top of CoO permits an alignment of the CoO Neél vector through field cooling in two otherwise equivalent [110] and [110] crystalline axes which are parallel and perpendicular to the Fe magnetization direction, respectively. Fe FMR linewidth is measured as a function of Ag thickness in 10-20-GHz frequency range and in 180-330 K temperature range. Furthermore, we find that there exists an anisotropy in the Fe FMR damping for parallel and perpendicular alignment of the Fe and CoO spins. However, such anisotropic damping exists only at thin Ag thickness where there exists a magnetic interlayer coupling between Fe and CoO, and vanishes at thick Ag thickness where the interlayer coupling becomes negligible but permitting spin-current transmission into CoO. Our result indicates the absence of anisotropic spin current for parallel and perpendicular alignment of the Fe and CoO spin axes.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Soluble limit and criticality of fermions in $\mathbb Z_2$ gauge theories

Quantum information theory and strongly correlated electron systems share a common theme of macroscopic quantum entanglement. In both topological error correction codes and theories of quantum materials (spin liquid, heavy fermion and high-$T_c$ systems), entanglement is implemented by means of an emergent gauge symmetry. Inspired by these connections, in this paper we introduce a simple model for fermions moving in the deconfined phase of a $\mathbb Z_2$ gauge theory by coupling Kitaev's toric code to mobile fermions. This permits us to exactly solve the ground state of this system and map out its phase diagram. Reversing the sign of the plaquette term in the toric code permits us to tune the ground state between an orthogonal metal and an orthogonal semimetal in which gapless quasiparticles survive despite a gap in the spectrum of original fermions. The small-to-large Fermi surface transition between these two states occurs in a stepwise fashion with multiple intermediate phases. By using a diagrammatic technique, we are able to explore physics beyond the integrable point to examine various instabilities of the deconfined phase and to derive the critical theory at the transition between deconfined and confined phases. We outline how the fermionic toric code can be implemented as a quantum circuit, thus providing an important link between quantum materials and quantum information theory.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Accurate localization of Kosterlitz-Thouless-type quantum phase transitions for one-dimensional spinless fermions

We investigate the charge-density wave (CDW) transition for one-dimensional spinless fermions at half band filling with nearest-neighbor electron transfer amplitude t and interaction V. The model is equivalent to the anisotropic XXZ Heisenberg model for which the Bethe Ansatz provides an exact solution. For V>V c =2t, the CDW order parameter and the single-particle gap are finite but exponentially small, as is characteristic for a Kosterlitz-Thouless transition. It is notoriously difficult to locate such infinite-order phase transitions in the phase diagram using approximate analytical and numerical approaches. Second-order Hartree-Fock theory is qualitatively applicable for all interaction strengths, and predicts the CDW transition to occur at V$^{(2)}_{c,2}$≈1.5t. Second-order Hartree Fock theory is almost variational because the density of quasiparticle excitations is small. We apply the density-matrix renormalization group (DMRG) for periodic boundary conditions for system sizes up to 514 sites, which permits a reliable extrapolation of all physical quantities to the thermodynamic limit, apart from the critical region. We investigate the ground-state energy, the gap, the order parameter, the momentum distribution, the quasiparticle density, and the density-density correlation function to locate V c from the DMRG data. In conclusion, tracing the breakdown of the Luttinger liquid and the peak in the quasiparticle density at the band edge permits us to reproduce V c with an accuracy of one percent.

1-dimensional spin chains↗

A novel inert crystal delivery medium for serial femtosecond crystallography

Serial femtosecond crystallography (SFX) has opened a new era in crystallography by permitting nearly damage-free, room-temperature structure determination of challenging proteins such as membrane proteins. In SFX, femtosecond X-ray free-electron laser pulses produce diffraction snapshots from nanocrystals and microcrystals delivered in a liquid jet, which leads to high protein consumption. A slow-moving stream of agarose has been developed as a new crystal delivery medium for SFX. It has low background scattering, is compatible with both soluble and membrane proteins, and can deliver the protein crystals at a wide range of temperatures down to 4°C. Using this crystal-laden agarose stream, the structure of a multi-subunit complex, phycocyanin, was solved to 2.5Å resolution using 300µg of microcrystals embedded into the agarose medium post-crystallization. The agarose delivery method reduces protein consumption by at least 100-fold and has the potential to be used for a diverse population of proteins, including membrane protein complexes.

Conrad, Chelsie E.↗

Balancing Participation and Speed: A Polycentric Governance Lens on Renewable‐Energy Siting

Siting and permitting for renewable projects vary in process and authority structures. Such variation can create coordination challenges and inconsistent public participation processes. We develop a Governance Trade-Off Matrix to classify permitting processes by (1) authority structure (polycentric vs. monocentric) and (2) procedural extensiveness (minimal vs. extensive). The matrix shows when jurisdictional dispersion enables timely implementation and when it creates coordination breakdowns. We propose testable hypotheses on how governance design affects project timelines, conflict escalation, and local acceptance. Here, the framework highlights design levers, like single lead agencies, structured public involvement, and statutory shot clocks, to reconcile meaningful local input with urgent climate imperatives.

14 SOLAR ENERGY↗

Thermal Assessment and In-Situ Monitoring of Insulated Gate Bipolar Transistors in Power Electronic Modules: Preprint

Insulated gate bipolar transistor (IGBT) power modules are devices commonly used for switching of high voltages and currents. Usage and environmental conditions can cause these power modules to degrade over time, and this gradual process may eventually lead to catastrophic failure of the device. This degradation process may cause some early performance symptoms related to the state of health of the power module, making it possible to detect reliability degradation of the IGBT module. Testing can be used to accelerate this process, permitting a rapid determination of whether specific declines in device reliability can be characterized. In this study, thermal cycling was conducted on multiple power modules simultaneously in order to assess the effect of thermal cycling on the degradation of the power module. In-situ monitoring of temperature was performed from inside each power module using high temperature thermocouples. Device imaging and characterization was performed along with temperature data analysis, to assess failure modes and mechanisms within the power modules. While the experiment was aimed to assess the potential damage effects of thermal cycling on die attach, results indicated that wirebond degradation was the life limiting failure mechanism.

33 ADVANCED PROPULSION SYSTEMS↗

Design optimization of MR-compatible rotating anode x-ray tubes for stable operation

Purpose: Hybrid x-ray/MR systems can enhance the diagnosis and treatment of endovascular, cardiac, and neurologic disorders by using the complementary advantages of both modalities for image guidance during interventional procedures. Conventional rotating anode x-ray tubes fail near an MR imaging system, since MR fringe fields create eddy currents in the metal rotor which cause a reduction in the rotation speed of the x-ray tube motor. A new x-ray tube motor prototype has been designed and built to be operated close to a magnet. To ensure the stability and safety of the motor operation, dynamic characteristics must be analyzed to identify possible modes of mechanical failure. In this study a 3D finite element method (FEM) model was developed in order to explore possible modifications, and to optimize the motor design. The FEM provides a valuable tool that permits testing and evaluation using numerical simulation instead of building multiple prototypes.Methods: Two experimental approaches were used to measure resonance characteristics: the first obtained the angular speed curves of the x-ray tube motor employing an angle encoder; the second measured the power spectrum using a spectrum analyzer, in which the large amplitude of peaks indicates large vibrations. An estimate of the bearing stiffness is required to generate an accurate FEM model of motor operation. This stiffness depends on both the bearing geometry and adjacent structures (e.g., the number of balls, clearances, preload, etc.) in an assembly, and is therefore unknown. This parameter was set by matching the FEM results to measurements carried out with the anode attached to the motor, and verified by comparing FEM predictions and measurements with the anode removed. The validated FEM model was then used to sweep through design parameters [bearing stiffness (1×10{sup 5}–5×10{sup 7} N/m), shaft diameter (0.372–0.625 in.), rotor diameter (2.4–2.9 in.), and total length of motor (5.66–7.36 in.)] to increase the fundamental frequency past the operating range at 50 Hz.Results: The first large vibration during the prototype motor operation was obtained at 21.64±0.68 Hz in the power spectrum. An abrupt decrease in acceleration occurred at 21.5 Hz due to struggling against the resonance vibrations. A bearing stiffness of 1.2×10{sup 5} N/m in the FEM simulation was used to obtain a critical speed of 21.4 Hz providing 1.1% error. This bearing stiffness value and the 3D model were then confirmed by the experiments with the anode removed, demonstrating an agreement within 6.4% between simulation results and measurements. A calculated first critical frequency (fundamental frequency) of 68.5 Hz was obtained by increasing the bearing stiffness to 1×10{sup 7} N/m and increasing the shaft diameter by 68.0%. Reducing the number of bearings in the design permits decreasing the total length of the motor by 1.7 in., and results in a fundamental frequency of 68.3 Hz in concert with additional changes (shaft diameter of 0.625 in., rotor diameter of 2.4 in., and bearing stiffness of 1×10{sup 6} N/m).Conclusions: An FEM model of the x-ray tube motor has been implemented and experimentally validated. A fundamental frequency above the operational rotation speed can be achieved through modification of multiple design parameters, which allows the motor to operate stably and safely in the MR environment during the repeated acceleration/deceleration cycles required for an interventional procedure. The validated 3D FEM model can now be used to investigate trade-offs between generated torque, maximum speed, and motor inertia to further optimize motor design.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

{sup 103}Pd strings: Monte Carlo assessment of a new approach to brachytherapy source design

Purpose: A new type of{sup 103}Pd source (CivaString and CivaThin by CivaTech Oncology, Inc.) is examined. The source contains {sup 103}Pd and Au radio-opaque marker(s), all contained within low-Z{sub eff} organic polymers that permit source flexibility. The CivaString source is available in lengths L of 10, 20, 30, 40, 50, and 60 mm, and referred to in the current study as CS10–CS60, respectively. A thinner design, CivaThin, has sources designated as CT10–CT60, respectively. The CivaString and CivaThin sources are 0.85 and 0.60 mm in diameter, respectively. The source design is novel and offers an opportunity to examine its interesting dosimetric properties in comparison to conventional {sup 103}Pd seeds. Methods: The MCNP5 radiation transport code was used to estimate air-kerma rate and dose rate distributions with polar and cylindrical coordinate systems. Doses in water and prostate tissue phantoms were compared to determine differences between the TG-43 formalism and realistic clinical circumstances. The influence of Ti encapsulation and 2.7 keV photons was examined. The accuracy of superposition of dose distributions from shorter sources to create longer source dose distributions was also assessed. Results: The normalized air-kerma rate was not highly dependent onL or the polar angle θ, with results being nearly identical between the CivaString and CivaThin sources for common L. The air-kerma strength was also weakly dependent on L. The uncertainty analysis established a standard uncertainty of 1.3% for the dose-rate constant Λ, where the largest contributors were μ{sub en}/ρ and μ/ρ. The Λ values decreased with increasing L, which was largely explained by differences in solid angle. The radial dose function did not substantially vary among the CivaString and CivaThin sources for r ≥ 1 cm. However, behavior for r < 1 cm indicated that the Au marker(s) shielded radiation for the sources having L = 10, 30, and 50 mm. The 2D anisotropy function exhibited peaks and valleys that corresponded to positions adjacent to {sup 103}Pd wells and Au markers, respectively. Dose distributions of both source types had minimal anisotropy in comparison to conventional {sup 103}Pd seeds. Contributions by 2.7 keV photons comprised ≤0.1% of the dose from all photons at positions farther than 0.13 mm from the polymer source surface. Differences between absorbed dose to water and prostate became more substantial as distance from the sources increased, with prostate dose being about 13% lower for r = 5 cm. Using a cylindrical coordinate system, dose superposition of small length sources to replicate the dose distribution for a long length source proved to be a robust technique; a 2.0% tolerance compared with the reference dose distribution did not exceed 0.1 cm{sup 3} for any of the examined source combinations. Conclusions: By design, the CivaString and CivaThin sources have novel dosimetric characteristics in comparison to Ti-encapsulated{sup 103}Pd seeds. The dosimetric characterization has determined the reasons for these differences through analysis using Monte Carlo-based radiation transport simulations.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Toward optimal organ at risk sparing in complex volumetric modulated arc therapy: An exponential trade-off with target volume dose homogeneity

Purpose: Conventional radiotherapy typically aims for homogenous dose in the planning target volume (PTV) while sparing organs at risk (OAR). The authors quantified and characterized the trade-off between PTV dose inhomogeneity (IH) and OAR sparing in complex head and neck volumetric modulated arc therapy plans. Methods: Thirteen simultaneous integrated boost plans were created per patient, for ten patients. PTV boost{sub (B)}/elective{sub (E)} optimization priorities were systematically increased. IH{sub B} and IH{sub E}, defined as (100% − V95%) + V107%, were evaluated against the average of the mean dose to the combined composite swallowing and combined salivary organs (D-OAR{sub comp}). To investigate the influence of OAR size and position with respect to PTV{sub B/E}, OAR dose was evaluated against a modified Euclidean distance (DM{sub B}/DM{sub E}) between OAR and PTV. Results: Although the achievable D-OAR{sub comp} for a given level of PTV IH differed between patients, excellent logarithmic fits described the D-OAR{sub comp}/IH{sub B} and IH{sub E} relationship in all patients (mean R{sup 2} of 0.98 and 0.97, respectively). Allowing an increase in average IH{sub B} and IH{sub E} over a clinically acceptable range, e.g., from 0.4% ± 0.5% to 2.0% ± 2.0% and 6.9% ± 2.8% to 14.8% ± 2.7%, respectively, corresponded to a decrease in average dose to the composite salivary and swallowing structures from 30.3 ± 6.5 to 23.6 ± 4.7 Gy and 32.5 ± 8.3 to 26.8 ± 9.3 Gy. The increase in PTV{sub E} IH was mainly accounted for by an increase in V107, by on average 5.9%, rather than a reduction in V95, which was on average only 2%. A linear correlation was found between the OAR dose to composite swallowing structures and contralateral parotid and submandibular gland, with DM{sub E} (R{sup 2} = 0.83, 0.88, 0.95). Only mean ipsilateral parotid dose correlated with DM{sub B} (R{sup 2} = 0.87). Conclusions: OAR sparing is highly dependent on the permitted PTV{sub B/E} IH. PTV{sub E} IH substantially influences OAR doses. These results are relevant for clinical practice and for future automated treatment-planning strategies.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-E-T-77: Comparison of 2D and 3D Gamma Analysis in Patient-Specific QA for Prostate VMAT Plans

Purpose: Patient-specific QA procedures for IMRT and VMAT are traditionally performed by comparing TPS calculations with measured single point values and plane dose distributions by means of gamma analysis. New QA devices permit us to calculate 3D dose distributions on patient anatomy as redundant secondary check and reconstruct it from measurements taken with 2D and 3D detector arrays. 3D dose calculations allow us to perform DVH-based comparisons with clinical relevance, as well as 3D gamma analysis. One of these systems (Compass, IBA Dosimetry) combines traditional 2D with new anatomical-based 3D gamma analysis. This work shows the ability of this system by comparing 2D and 3D gamma analysis in pre-treatment QA for several VMAT prostate plans. Methods: Compass is capable of calculating dose as secondary check from DICOM TPS data and reconstructing it from measurements taken by a 2D ion chamber array (MatriXX Evolution, IBA Dosimetry). Both 2D and 3D gamma tests are available to compare calculated and reconstructed dose in Compass with TPS RT Dose. Results: 15 VMAT prostate plans have been measured with Compass. Dose is reconstructed with Compass for these plans. 2D gamma comparisons can be done for any plane from dose matrix. Mean gamma passing rates for isocenter planes (axial, coronal, sagittal) are (99.7±0.2)%, (99.9±0.1)%, (99.9±0.1)% for reconstructed dose planes. 3D mean gamma passing rates are (98.5±1.7)% for PTVs, (99.1±1.5)% for rectum, (100.0±0.0)% for bladder, (99.6±0.7)% for femoral heads and (98.1±4.1)% for penile bulb. Conclusion: Compass is a powerful tool to perform a complete pre-treatment QA analysis, from 2D techniques to 3D DVH-based techniques with clinical relevance. All reported values for VMAT prostate plans are in good agreement with TPS values. This system permits us to ensure the accuracy in the delivery of VMAT treatments completing a full patient-specific QA program.

60 APPLIED LIFE SCIENCES↗

Harmonic analysis for the characterization and correction of geometric distortion in MRI

Purpose: Magnetic resonance imaging (MRI) is gaining widespread use in radiation therapy planning, patient setup verification, and real-time guidance of radiation delivery. Successful implementation of these technologies relies on the development of simple and efficient methods to characterize and monitor the geometric distortions arising due to system imperfections and gradient nonlinearities. To this end, the authors present the theory and validation of a novel harmonic approach to the quantification of system-related distortions in MRI. Methods: The theory of spatial encoding in MRI is applied to demonstrate that the 3D distortion vector field (DVF) is given by the solution of a second-order boundary value problem (BVP). This BVP is comprised of Laplace’s equation and a limited measurement of the distortion on the boundary of a specified region of interest (ROI). An analytical series expansion solving this BVP within a spherical ROI is obtained, and a statistical uncertainty analysis is performed to determine how random errors in the boundary measurements propagate to the ROI interior. This series expansion is then evaluated to obtain volumetric DVF mappings that are compared to reference data obtained on a 3 T full-body scanner. This validation is performed within two spheres of 20 cm diameter (one centered at the scanner origin and the other offset +3 cm along each of the transverse directions). Initially, a high-order mapping requiring measurements at 5810 boundary points is used. Then, after exploring the impact of the boundary sampling density and the effect of series truncation, a reduced-order mapping requiring measurements at 302 boundary points is evaluated. Results: The volumetric DVF mappings obtained from the harmonic analysis are in good agreement with the reference data. Following distortion correction using the high-order mapping, the authors estimate a reduction in the mean distortion magnitude from 0.86 to 0.42 mm and from 0.93 to 0.39 mm within the central and offset ROIs, respectively. In addition, the fraction of points with a distortion magnitude greater than 1 mm is reduced from 35.6% to 2.8% and from 40.4% to 1.5%, respectively. Similarly, following correction using the reduced-order mapping, the mean distortion magnitude reduces to 0.45–0.42 mm within the central and offset ROIs, and the fraction of points with a distortion magnitude greater than 1 mm is reduced to 2.8% and 1.5%, respectively. Conclusions: A novel harmonic approach to the characterization of system-related distortions in MRI is presented. This method permits a complete and accurate mapping of the DVF within a specified ROI using a limited measurement of the distortion on the ROI boundary. This technique eliminates the requirement to exhaustively sample the DVF at a dense 3D array of points, thereby permitting the design of simple, inexpensive phantoms that may incorporate additional modules for auxiliary quality assurance objectives.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

WE-B-210-00: Carson/Zagzebski Distinguished Lectureship

In the last fifteen years, the introduction of plane or diverging wave transmissions rather than line by line scanning focused beams has broken the conventional barriers of ultrasound imaging. By using such large field of view transmissions, the frame rate reaches the theoretical limit of physics dictated by the ultrasound speed and an ultrasonic map can be provided typically in tens of micro-seconds (several thousands of frames per second). Interestingly, this leap in frame rate is not only a technological breakthrough but it permits the advent of completely new ultrasound imaging modes, including shear wave elastography, electromechanical wave imaging, ultrafast doppler, ultrafast contrast imaging, and even functional ultrasound imaging of brain activity (fUltrasound) introducing Ultrasound as an emerging full-fledged neuroimaging modality. At ultrafast frame rates, it becomes possible to track in real time the transient vibrations – known as shear waves – propagating through organs. Such “human body seismology” provides quantitative maps of local tissue stiffness whose added value for diagnosis has been recently demonstrated in many fields of radiology (breast, prostate and liver cancer, cardiovascular imaging, …). Today, Supersonic Imagine company is commercializing the first clinical ultrafast ultrasound scanner, Aixplorer with real time Shear Wave Elastography. This is the first example of an ultrafast Ultrasound approach surpassing the research phase and now widely spread in the clinical medical ultrasound community with an installed base of more than 1000 Aixplorer systems in 54 countries worldwide. For blood flow imaging, ultrafast Doppler permits high-precision characterization of complex vascular and cardiac flows. It also gives ultrasound the ability to detect very subtle blood flow in very small vessels. In the brain, such ultrasensitive Doppler paves the way for fUltrasound (functional ultrasound imaging) of brain activity with unprecedented spatial and temporal resolution compared to fMRI. Combined with contrast agents, our group demonstrated that Ultrafast Ultrasound Localization could provide a first in vivo and non invasive imaging modality at microscopic scales deep into organs. Many of these ultrafast modes should lead to major improvements in ultrasound screening, diagnosis, and therapeutic monitoring. Learning Objectives: Achieve familiarity with recent advances in ultrafast ultrasound imaging technology. Develop an understanding of potential applications of ultrafast ultrasound imaging for diagnosis and therapeutic monitoring. Dr. Tanter is a co-founder of Supersonic Imagine,a French company positioned in the field of medical ultrasound imaging and therapy.

60 APPLIED LIFE SCIENCES↗

WE-B-210-01: Introduction

In the last fifteen years, the introduction of plane or diverging wave transmissions rather than line by line scanning focused beams has broken the conventional barriers of ultrasound imaging. By using such large field of view transmissions, the frame rate reaches the theoretical limit of physics dictated by the ultrasound speed and an ultrasonic map can be provided typically in tens of micro-seconds (several thousands of frames per second). Interestingly, this leap in frame rate is not only a technological breakthrough but it permits the advent of completely new ultrasound imaging modes, including shear wave elastography, electromechanical wave imaging, ultrafast doppler, ultrafast contrast imaging, and even functional ultrasound imaging of brain activity (fUltrasound) introducing Ultrasound as an emerging full-fledged neuroimaging modality. At ultrafast frame rates, it becomes possible to track in real time the transient vibrations – known as shear waves – propagating through organs. Such “human body seismology” provides quantitative maps of local tissue stiffness whose added value for diagnosis has been recently demonstrated in many fields of radiology (breast, prostate and liver cancer, cardiovascular imaging, …). Today, Supersonic Imagine company is commercializing the first clinical ultrafast ultrasound scanner, Aixplorer with real time Shear Wave Elastography. This is the first example of an ultrafast Ultrasound approach surpassing the research phase and now widely spread in the clinical medical ultrasound community with an installed base of more than 1000 Aixplorer systems in 54 countries worldwide. For blood flow imaging, ultrafast Doppler permits high-precision characterization of complex vascular and cardiac flows. It also gives ultrasound the ability to detect very subtle blood flow in very small vessels. In the brain, such ultrasensitive Doppler paves the way for fUltrasound (functional ultrasound imaging) of brain activity with unprecedented spatial and temporal resolution compared to fMRI. Combined with contrast agents, our group demonstrated that Ultrafast Ultrasound Localization could provide a first in vivo and non invasive imaging modality at microscopic scales deep into organs. Many of these ultrafast modes should lead to major improvements in ultrasound screening, diagnosis, and therapeutic monitoring. Learning Objectives: Achieve familiarity with recent advances in ultrafast ultrasound imaging technology. Develop an understanding of potential applications of ultrafast ultrasound imaging for diagnosis and therapeutic monitoring. Dr. Tanter is a co-founder of Supersonic Imagine,a French company positioned in the field of medical ultrasound imaging and therapy.

60 APPLIED LIFE SCIENCES↗

WE-B-210-02: The Advent of Ultrafast Imaging in Biomedical Ultrasound

In the last fifteen years, the introduction of plane or diverging wave transmissions rather than line by line scanning focused beams has broken the conventional barriers of ultrasound imaging. By using such large field of view transmissions, the frame rate reaches the theoretical limit of physics dictated by the ultrasound speed and an ultrasonic map can be provided typically in tens of micro-seconds (several thousands of frames per second). Interestingly, this leap in frame rate is not only a technological breakthrough but it permits the advent of completely new ultrasound imaging modes, including shear wave elastography, electromechanical wave imaging, ultrafast doppler, ultrafast contrast imaging, and even functional ultrasound imaging of brain activity (fUltrasound) introducing Ultrasound as an emerging full-fledged neuroimaging modality. At ultrafast frame rates, it becomes possible to track in real time the transient vibrations – known as shear waves – propagating through organs. Such “human body seismology” provides quantitative maps of local tissue stiffness whose added value for diagnosis has been recently demonstrated in many fields of radiology (breast, prostate and liver cancer, cardiovascular imaging, …). Today, Supersonic Imagine company is commercializing the first clinical ultrafast ultrasound scanner, Aixplorer with real time Shear Wave Elastography. This is the first example of an ultrafast Ultrasound approach surpassing the research phase and now widely spread in the clinical medical ultrasound community with an installed base of more than 1000 Aixplorer systems in 54 countries worldwide. For blood flow imaging, ultrafast Doppler permits high-precision characterization of complex vascular and cardiac flows. It also gives ultrasound the ability to detect very subtle blood flow in very small vessels. In the brain, such ultrasensitive Doppler paves the way for fUltrasound (functional ultrasound imaging) of brain activity with unprecedented spatial and temporal resolution compared to fMRI. Combined with contrast agents, our group demonstrated that Ultrafast Ultrasound Localization could provide a first in vivo and non invasive imaging modality at microscopic scales deep into organs. Many of these ultrafast modes should lead to major improvements in ultrasound screening, diagnosis, and therapeutic monitoring. Learning Objectives: Achieve familiarity with recent advances in ultrafast ultrasound imaging technology. Develop an understanding of potential applications of ultrafast ultrasound imaging for diagnosis and therapeutic monitoring. Dr. Tanter is a co-founder of Supersonic Imagine,a French company positioned in the field of medical ultrasound imaging and therapy.

60 APPLIED LIFE SCIENCES↗