Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “performance improvement”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 847 records · Page 47

Physics-based seismic hazard analysis on petascale heterogeneous supercomputers, In: SC '13 Proceedings of the International Conference on High Performance Computing, Networking, Storage and Analysis

We have developed a highly scalable and efficient GPU-based finite-difference code (AWP) for earthquake simulation that implements high throughput, memory locality, communication reduction and communication/computation overlap and achieves linear scalability on Cray XK7 Titan at ORNL and NCSA's Blue Waters system. We simulate realistic 0-10 Hz earthquake ground motions relevant to building engineering design using high-performance AWP. Moreover, we show that AWP provides a speedup by a factor of 110 in key strain tensor calculations critical to probabilistic seismic hazard analysis (PSHA). These performance improvements to critical scientific application software, coupled with improved co-scheduling capabilities of our workflow-managed systems, make a statewide hazard model a goal reachable with existing supercomputers. The performance improvements of GPU-based AWP are expected to save millions of core-hours over the next few years as physics-based seismic hazard analysis is developed using heterogeneous petascale supercomputers.

Computer Science↗

Performance of a Laser Ignited Multicylinder Lean Burn Natural Gas Engine

Market demands for lower fueling costs and higher specific powers in stationary natural gas engines has engine designs trending towards higher in-cylinder pressures and leaner combustion operation. However, Ignition remains as the main limiting factor in achieving further performance improvements in these engines. Addressing this concern, while incorporating various recent advances in optics and laser technologies, laser igniters were designed and developed through numerous iterations. Final designs incorporated water-cooled, passively Q-switched, Nd:YAG micro-lasers that were optimized for stable operation under harsh engine conditions. Subsequently, the micro-lasers were installed in the individual cylinders of a lean-burn, 350 kW, inline 6-cylinder, open-chamber, spark ignited engine and tests were conducted. To the best of our knowledge, this is the world’s first demonstration of a laser ignited multi-cylinder natural gas engine. The engine was operated at high-load (298 kW) and rated speed (1800 rpm) conditions. Ignition timing sweeps and excess-air ratio (λ) sweeps were performed while keeping the NOx emissions below the USEPA regulated value (BSNOx < 1.34 g/kW-hr), and while maintaining ignition stability at industry acceptable values (COV_IMEP <5 %). Through such engine tests, the relative merits of (i) standard electrical ignition system, and (ii) laser ignition system were determined. In conclusion, a rigorous combustion data analysis was performed and the main reasons leading to improved performance in the case of laser ignition were identified.

33 ADVANCED PROPULSION SYSTEMS↗

Improved Saturation Performance in High Speed Waveguide Photodetectors at 1.3 ??sing an Asymmetric InA1GaAs/InGaAsP Structure

Waveguide photodetector (WGPD) results have recently been presented demonstrating the very large bandwidth-efficiency product potential of these devices. Improved saturation and linearity characteristics are realized in waveguide p-i-n photodetectors at 1.3 ??y using an asymmetric cladding structure with InA1GaAs/InGaAsP in the anode and InGaAsP in the cathode.

multi-mode structures photocurrent saturation wave↗

Smart monitoring system based on adaptive current control for superconducting cable test

A smart monitoring system for superconducting cable test is proposed with an adaptive current control of a superconducting transformer secondary. The design, based on Fuzzy Gain Scheduling, allows the controller parameters to adapt continuously, and finely, to the working variations arising from transformer nonlinear dynamics. The control system is integrated in a fully digital control loop, with all the related benefits, i.e., high noise rejection, ease of implementation/modification, and so on. In particular, an accurate model of the system, controlled by a Fuzzy Gain Scheduler of the superconducting transformer, was achieved by an experimental campaign through the working domain at several current ramp rates. The model performance was characterized by simulation, under all the main operating conditions, in order to guide the controller design. Finally, the proposed monitoring system was experimentally validated at European Organization for Nuclear Research (CERN) in comparison to the state-of-the-art control system [P. Arpaia, L. Bottura, G. Montenero, and S. Le Naour, “Performance improvement of a measurement station for superconducting cable test,” Rev. Sci. Instrum.83, 095111 (2012)] of the Facility for the Research on Superconducting Cables, achieving a significant performance improvement: a reduction in the system overshoot by 50%, with a related attenuation of the corresponding dynamic residual error (both absolute and RMS) up to 52%.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

System structural test results - Six PODS III supports

Passive orbital disconnect struts can potentially reduce the support conductance a factor of 10 over state-of-the-art tension band nondisconnect supports and cut helium dewar weights in half for the same lifetime. A series of thermal and structural tests were performed to verify that this performance improvement is real. Structural tests on a PODS-III support system (consisting of six struts) is reported here. The results show the predicted performance improvements can be achieved and the PODS-III supports are ready for flight applications. For large tankage systems requiring higher side load capability, a PODS-IV version is currently being developed.

Parmley, Richard T.↗

SU-C-BRA-04: Automated Segmentation of Head-And-Neck CT Images for Radiotherapy Treatment Planning Via Multi-Atlas Machine Learning (MAML)

Purpose: Accurate image segmentation is a crucial step during image guided radiation therapy. This work proposes multi-atlas machine learning (MAML) algorithm for automated segmentation of head-and-neck CT images. Methods: As the first step, the algorithm utilizes normalized mutual information as similarity metric, affine registration combined with multiresolution B-Spline registration, and then fuses together using the label fusion strategy via Plastimatch. As the second step, the following feature selection strategy is proposed to extract five feature components from reference or atlas images: intensity (I), distance map (D), box (B), center of gravity (C) and stable point (S). The box feature B is novel. It describes a relative position from each point to minimum inscribed rectangle of ROI. The center-of-gravity feature C is the 3D Euclidean distance from a sample point to the ROI center of gravity, and then S is the distance of the sample point to the landmarks. Then, we adopt random forest (RF) in Scikit-learn, a Python module integrating a wide range of state-of-the-art machine learning algorithms as classifier. Different feature and atlas strategies are used for different ROIs for improved performance, such as multi-atlas strategy with reference box for brainstem, and single-atlas strategy with reference landmark for optic chiasm. Results: The algorithm was validated on a set of 33 CT images with manual contours using a leave-one-out cross-validation strategy. Dice similarity coefficients between manual contours and automated contours were calculated: the proposed MAML method had an improvement from 0.79 to 0.83 for brainstem and 0.11 to 0.52 for optic chiasm with respect to multi-atlas segmentation method (MA). Conclusion: A MAML method has been proposed for automated segmentation of head-and-neck CT images with improved performance. It provides the comparable result in brainstem and the improved result in optic chiasm compared with MA. Xuhua Ren and Hao Gao were partially supported by the NSFC (#11405105), the 973 Program (#2015CB856000), and the Shanghai Pujiang Talent Program (#14PJ1404500).

60 APPLIED LIFE SCIENCES↗

MFIX DEM Enhancement for Industry-Relevant Flows (Final Report)

The overall goal of this two-phase project is to implement performance improvements of the Multiphase Flow with Interphase Exchanges (MFIX) Discrete Element Model (DEM) code that enable a transformative shift for industrial use. Prior to this effort, the largest simulations performed using MFIX are O(10 7 ) particles. This falls short of the O(10 9 ) particle simulations that must be completed on a timescale of days or weeks (vs. months or years) to enable simulations with physically-relevant domain sizes to be incorporated into industrial design cycles within five years. This was accomplished by tailoring best-in-class practices to bear on the unique challenges posed by the MFIX-DEM algorithm and code base. Scientific simulations (e.g., in cosmology, turbulent combustion) routinely use massively parallel computing to update far more particles in short wall clock times. Results from Phase 1 (1.5 years in duration) indicated significant gains in speed were possible for a wide range of benchmark cases. Moreover, a survey sent to >35 companies indicates that the timing is ideal for such an enhanced tool, with >80% of the respondents indicating that DEM is already value-added or will be within the next 5 years, and >70% of the respondents indicating that improved speed is the top computational priority. In Phase 2 (3.5 years in duration), the two major barriers that hinder industry from effectively using multiphase Computational Fluid Dynamics (CFD) to cut costs and improve performance, namely computational overhead and confidence in predictions, continued to be addressed. Regarding the former, the results from Phase 1 to guide the effort, with enhancements focused on an improved time-stepping algorithm and particle sorting. Four target problems of 1 billion particles each and increasing complexity were identified: homogeneous cooling, tumbler with continuous particle size distribution, discharge from a rectangular hopper and a cylindrical riser. Each of these were successfully simulated for relevant time scales (on order of seconds) using less than 24 hours of wall clock time. These represent the first 1-billion particle DEM simulations performed with MFIX, namely using the MFIX-Exa code. This code is currently under development at NETL in collaboration with Lawrence Berkeley National Laboratory. Regarding the second barrier on predictive uncertainty, experiments from Phase 1 (interacting nozzles - hydrodynamics only) and Phase 2 (very small-scale segregation experiments) were used to demonstrate the ability of two simplified approaches to uncertainty quantification (UQ). By limiting the number of particles, UQ based on the simplified treatment was compared to standard UQ, which was shown to have much higher computational demands. Experiments were also performed on a pilot-scale stripper unit to provide validation data for future CFD-DEM simulations and UQ.

20 FOSSIL-FUELED POWER PLANTS↗

Performance Assessments of Demand Flexibility from Grid-Interactive Efficient Buildings: Issues and Considerations

This SEE Action Network report explains basic concepts and fundamental considerations for assessing the actual demand flexibility performance of buildings participating in demand flexibility programs and responding to time-varying retail rates. Demand flexibility is the capability of distributed energy resources (DERs) to adjust a building’s load profile across different timescales. Assessments determine the timing, location, quantity, and quality of grid services provided. The results can be used for financial settlements and to improve performance of demand flexibility, support its consideration in resource potential studies and electricity system planning, and contribute to cost-effectiveness evaluations. While practitioners and regulators regularly find opportunities to improve performance assessments of demand-related services, to a large degree current best practices are sufficient for basic service offerings as demand flexibility is implemented today. However, advances in assessment practices will be required in a future with grid-interactive efficient buildings (GEBs) that provide continuous demand flexibility by integrating multiple DERs and flexibility modes (load shed, load shift, modulate, and generate). Example practices include using new baseline constructs—including whether baselines are even required for certain building flexibility modes or configurations, deploying more advanced metering and analytics, further developing cybersecurity standards, improving communication standards for increased interoperability, and establishing performance metrics and assessment procedures for load modulation as it is more fully defined and implemented. This report provides information on prioritizing and designing performance assessment elements for demand flexibility programs and time-varying retail rates, assessment protocols, and research and development needs. Additional research sponsored by DOE’s Building Technologies Office offers more detailed technical information on assessing performance of demand flexibility, including definition of performance metrics.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Advanced Energy Retrofit Guide: Practical Ways to Improve Energy Performance; Grocery Stores (Revised) [Book]

The U.S. Department of Energy developed the Advanced Energy Retrofit Guides (AERGs) to provide specific methodologies, information, and guidance to help energy managers and other stakeholders successfully plan and execute energy efficiency improvements. Detailed technical discussion is fairly limited in these guides. Instead, we emphasize actionable information, practical methodologies, diversecase studies, and unbiased evaluations of the most promising retrofit measures for each building type. A series of AERGs is under development, addressing key segments of the commercial building stock. Grocery stores were selected as one of the highest priority sectors, because they represent one of the most energy-intensive market segments.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Adapting Wave-front Algorithms to Efficiently Utilize Systems with Deep Communication Hierarchies

Large-scale systems increasingly exhibit a differential between intra-chip and inter-chip communication performance especially in hybrid systems using accelerators. Processorcores on the same socket are able to communicate at lower latencies, and with higher bandwidths, than cores on different sockets either within the same node or between nodes. A key challenge is to efficiently use this communication hierarchy and hence optimize performance. We consider here the class of applications that contains wavefront processing. In these applications data can only be processed after their upstream neighbors have been processed. Similar dependencies result between processors in which communication is required to pass boundary data downstream and whose cost is typically impacted by the slowest communication channel in use. In this work we develop a novel hierarchical wave-front approach that reduces the use of slower communications in the hierarchy but at the cost of additional steps in the parallel computation and higher use of on-chip communications. This tradeoff is explored using a performance model. An implementation using the Reverse-acceleration programming model on the petascale Roadrunner system demonstrates a 27% performance improvement at full system-scale on a kernel application. The approach is generally applicable to large-scale multi-core and accelerated systems where a differential in system communication performance exists.

43 PARTICLE ACCELERATORS↗

Long-Term Heating to Improve Receiver Performance

The buildup of hydrogen in the heat transfer fluid (HTF) that circulates through components of parabolic trough power plants decreases receiver thermal efficiency, and ultimately, it decreases plant performance and electricity output. The generation and occurrence of hydrogen in the HTF provides the driving force for hydrogen to permeate from the HTF through the absorber tube wall and into the receiver annulus. Getters adsorb hydrogen from the annulus volume until they saturate and are no longer able to maintain low hydrogen pressure. The increase in hydrogen pressure within the annulus significantly degrades thermal performance of the receiver and decreases overall power-plant efficiency. NREL and Acciona Energy North America (Acciona) are developing a method to control the levels of dissolved hydrogen in the circulating HTF. The basic approach is to remove hydrogen from the expansion tanks of the HTF subsystem at a rate that maintains hydrogen in the circulating HTF to a target level. Full-plant steady-state models developed by the National Renewable Energy Laboratory (NREL) predict that if hydrogen is removed from the HTF within the expansion tanks, the HTF that circulates through the collector field remains essentially free of hydrogen until the HTF returns to the power block in the hot headers. One of the key findings of our modeling is the prediction that hydrogen will reverse-permeate out of the receiver annulus if dissolved hydrogen in the HTF is kept sufficiently low. To test this prediction, we performed extended heating of an in-service receiver that initially had high levels of hydrogen in its annulus. The heating was performed using NREL's receiver test stand. Results of our testing showed that receiver heat loss steadily decreased with daily heating, resulting in a corresponding improvement in receiver thermal efficiency.

14 SOLAR ENERGY↗

I/O Parallelization for the Goddard Earth Observing System Data Assimilation System (GEOS DAS)

The National Aeronautics and Space Administration (NASA) Data Assimilation Office (DAO) at the Goddard Space Flight Center (GSFC) has developed the GEOS DAS, a data assimilation system that provides production support for NASA missions and will support NASA's Earth Observing System (EOS) in the coming years. The DAO's support of the EOS project along with the requirement of producing long-term reanalysis datasets with an unvarying system levy a large I/O burden on the future system. The DAO has been involved in prototyping parallel implementations of the GEOS DAS for a number of years and is now converting the production version from shared-memory parallelism to distributed-memory parallelism using the portable Message-Passing Interface (MPI). If the MPI-based GEOS DAS is to meet these production requirements, we must make I/O from the parallel system efficient. We have designed a scheme that allows efficient I/O processing while retaining portability, reducing the need for post-processing, and producing data formats that are required by our users, both internal and external. The first phase of the GEOS DAS Parallel I/O System (GPIOS) will expand upon the common method of gathering global data to a Single PE for output. Instead of using a PE also tasked with primary computation, a number of PEs will be dedicated to I/O and its related tasks. This allows the data transformations and formatting required prior to output to take place asynchronously with respect to the GEOS DAS assimilation cycle, improving performance and generating output data sets in a format convenient for our users. I/O PEs can be added as needed to handle larger data volumes or to meet user file specifications. We will show I/O performance results from a prototype MPI GCM integrated with GPIOS. Phase two of GPIOS development will examine ways of integrating new software technologies to further improve performance and build scalability into the system. The maturing of MPI-IO implementations and other supporting libraries such as parallel HDF should provide performance gains while retaining portability.

Lucchesi, R.↗

Improvements and Performance of the Fermilab Solenoid Test Facility

Here, the Solenoid Test Facility at Fermilab was built using a large vacuum vessel for testing of conduction-cooled superconducting solenoid magnets, and was first used to determine the performance of the MICE Coupling Coil. The facility was modified recently to enable testing of solenoid magnets for the Mu2e experiment, which operate at much higher current than the Coupling Coil. One pair of low current conduction-cooled copper and NbTi leads was replaced with two pairs of 10 kA HTS leads cooled by heat exchange with liquid nitrogen and liquid helium. The new design, with additional control and monitoring capability, also provides helium cooling of the superconducting magnet leads by conduction. A high current power supply with energy extraction was added, and several improvements to the quench protection and characterization system were made. Here we present details of these changes and report on performance results from a test of the Mu2e prototype Transport Solenoid (TS) module. Progress on additional improvements in preparation for production TS module testing will be presented.

43 PARTICLE ACCELERATORS↗

Advanced Energy Retrofit Guide: Practical Ways to Improve Energy Performance, K-12 Schools (Book)

The U.S. Department of Energy developed the K-12 Advanced Energy Retrofit Guide to provide specific methodologies, information, and guidance to help energy managers and other stakeholders plan and execute energy efficiency improvements. We emphasize actionable information, practical methodologies, diverse case studies, and unbiased evaluation of the most promising retrofit measure for each building type. K-12 schools were selected as one of the highest priority building sectors, because schools affect the lives of most Americans. They also represent approximately 8% of the energy use and 10% of the floor area in commercial buildings.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Measured performance of a tip-controlled, teetered rotor with an NACA 64 sub 3-618 tip airfoil

Tests were conducted on the Mod-O 100 kW Wind Turbine to determine the performance of a tip-controlled rotor having an NACA 64 sub-618 airfoil over the moveable outboard 30% of the blade, while operating at nominal rotor speeds of 21 and 31 rpm. Tests were conducted at two rotor speeds to assess the performance improvement which could be realized with 2-speed operation. Test data are compared with analytical predictions and concluding remarks are presented. The results indicate a clear performance improvement for the 2-speed operation.

Corrigan, R. D.↗

Single Ion Conducting Hairy Nanoparticle Additive to Improve Cycling Stability of Solid Polymer Electrolytes

The development of a solid electrolyte that can impede dendrite growth while still maintaining an appropriate level of conductivity is essential for improving performance of solid-state Li-ion battery. In this paper, we report the synthesis of single Li-ion conducting hairy nanoparticle (NP) materials that improved the cycling stability of lithium bis(trifluoromethanesulfonyl)imide (LiTFSI)-doped poly(ethylene oxide) (PEO) solid electrolyte without significant reduction in conductivity. To unveil mechanisms leading to improved cycling stability, several characterization techniques including broadband dielectric spectroscopy, differential scanning calorimetry, small angle X-ray scattering, transmission electron microscopy, and shear rheology were used to study properties of polymer composites (PC) with added hairy NPs. It was found that hairy NPs influenced the Li/electrolyte interface and improved mechanical properties of bulk composites, all of which contributed to homogenous Li plating and stripping. The improved performance has been found in composites with concentrations of 4.8 and 9.1 weight % of added hairy NPs, which enabled Li cycling stability at 0.2 mA cm–2 critical current density (>300 h) that was otherwise not possible in either PEO-LiTFSI alone or PEO-LiTFSI composites containing a polymer identical to that attached to hairy NPs. Based on the discovered ability of hairy NP to influence bulk and interfacial properties of solid electrolyte, their use as additives is expected to be equally effective in reducing dendrite formation in other electrolytes relevant for the design of solid-state battery.

25 ENERGY STORAGE↗

Elucidating the Role of Hydroxide Electrolyte on Anion-Exchange-Membrane Water Electrolyzer Performance

Many solid-state devices, especially those requiring anion conduction, often add a supporting electrolyte to enable efficient operation. The prototypical case is that of anion-exchange-membrane water electrolyzers (AEMWEs), where addition of an alkali metal solution improves performance. However, the specific mechanism of this performance improvement is currently unknown. This work investigates the functionality of the alkali metal solution in AEMWEs using experiments and mathematical models. The results show that additional hydroxide plays a key role not only in ohmic resistance of the membrane and catalyst layer but also in the reaction kinetics. The modeling suggests that the added liquid electrolyte creates an additional electrochemical interface with the electrocatalyst that provides ion-transport pathways and distributes product gas bubbles; the total effective electrochemical active surface area in the cell with 1 M KOH is 5 times higher than that of the cell with DI water. In the cell with 1 M KOH, more than 80% of the reaction current is associate with the liquid electrolyte. These results indicate the importance of high pH of electrolyte and catalyst/electrolyte interface in AEMWEs. The understanding of the functionality of the alkali metal solution presented in this study should help guide the design and optimization of AEMWEs.

25 ENERGY STORAGE↗

Potential Weight Benefits of IM7/8552 Hybrid Thin-Ply Composites for Aircraft Structures

Composite materials have increasingly been used for aerospace applications due to improved performance and reduced weight compared to their metallic counterparts. Inclusion of thin-ply material, plies with cured thickness half or less than standard-ply composites, have potential to improve performance and reduce structural weight further. The effect of thin-ply material on the weight of aircraft structure was investigated by examining wing cover weight reduction. To minimize the effects on manufacturing due to using thin plies, hybrid laminates were examined that used thin ±45-degree plies to replace their standard-ply counterparts in laminates. Compression after impact (CAI) tests were conducted to examine the possible weight savings that could be gained by increasing the design allowables that were used to size the wing upper cover of a semi-span test article. A large increase in CAI strength was observed for quasi-isotropic hybrid laminates, whereas less improvement was seen for hard hybrid laminates such as found in the wing cover. For laminates design by CAI strength, weight savings of about 13% were found using the hybrid hard laminates compared to the standard-ply laminates. Whether similar weight savings could be expected for structure sized using tension after impact allowables will have to be investigated further. Notched specimens were tested to examine possible weight savings using hybrid laminates in regions that are sized using discrete source damage requirements. As expected, the hybrid laminate had marginal improvements over the standard-ply laminate for compression with a notch present. The hybrid laminate, however, exhibited about 20% lower strength than the standard-ply laminate counterpart for tension with a notch. The failure mode of the hybrid specimens was a brittle, self-similar crack, which differs from the standard-ply specimens that failed by significant amounts of delamination and fiber splitting. In light of the apparent reduction in notched tensile strength, additional investigation is required to assess the use of hybrid laminates for areas containing discrete source damage, and their effect on weight of such regions.

Lovejoy, Andrew E.↗