Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “measurment”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 847 records · Page 47

Intensity and Self-Broadening Measurements of the 01(exp 1)21-00(exp 0)01 CO2 Perpendicular Band at 5315/cm

The near-infrared thermal emission windows in the spectrum of the night-side of Venus have stimulated new determinations of the intensities of weak CO2 bands which are prominent absorption features in Venus spectra. Parameters for many unmeasured bands have been recomputed for the HITRAN compilation using direct numerical diagonalization (DND) [Wattson and Rothman, J.Q.S.R.T. 48, 763 (1992)]. To assess these HITRAN values, we have been measuring several of these bands on spectra which were obtained using the Kitt Peak McMath FTS and 6-meter White cell. Last year we presented preliminary intensity measurements of the 01(exp 1)21-00(exp 0)01 perpendicular band and 4 associated hot bands, Five additional McMath FTS spectra have now been obtained covering the region 3800 to 8400/cm. This permits us to finalize our intensity measurements, and to make an assessment of their uncertainties. We anticipate that these measured values will help improve further DND calculations of many weak unmeasureable bands. In addition, self-broadening parameters were determined for some lines of the 01(exp 1)21-00(exp 0)01 perpendicular band on spectra obtained with 65 and 80 torr of CO2. Because of the large spectral range, these measurements could be compared directly to self-broadening parameters of corresponding parallel. band lines measured on the same spectra. This procedure eliminates several possible sources of systematic errors that are important when attempting to determine whether or not corresponding rotational lines in different overtone-combination bands have significant differences. Our measurements thus far have found self-broadening parameters for the 01(exp 1)21-00(exp 0)01 perpendicular band to be slightly larger than similar measurements for the 30(exp 0)14-00(exp 0)01 parallel band at 6076/cm.

Giver, Lawrence P.↗

Correlation of the Coronal Mass Ejection Productivity of Solar Active Regions with Measures of their Global Nonpotentiality from Vector Magnetograms: Baseline Results

Conventional magnetograms and chromospheric and coronal images show qualitatively that the fastest coronal mass ejections (CMEs) are magnetic explosions from sunspot active regions where the magnetic field is globally strongly sheared and twisted from its minimum-energy potential configuration. We present measurements from active region vector magnetograms that start to quantify the dependence of an active region's CME productivity on the global nonpotentiality of its magnetic field. From each of 17 magnetograms of 12 bipolar active regions, we measured the size of the active region (the magnetic flux content, phi) and three separate measures of the global nonpotentiality (L(sub SS), the length of strong-shear, strong-field main neutral line: I(sub N), the net electric current connecting one polarity to the other; and alpha = (mu)I(sub N)/phi), a flux normalized measure of the field twist). From these measurements and the observed CME productivity of the active regions, we find that: (1) All three measures of global nonpotentiality are statistically correlated with the active region flux content and with each other; (2) All three measures of global nonpotentiality are significantly correlated with CME productivity. The flux content correlates with CME productivity, but at a lower statistically significant confidence level (less than 95%); (3) The net current is less closely correlated with CME productivity than alpha and the correlation of CME productivity with flux content is even weaker. If these differences in correlation strength, and a significant correlation of alpha with flux content, persist to larger active regions, this would imply that the size of active regions does not affect CME productivity except through global nonpotentiality; and (4) For each of the four global magnetic quantities, the correlation with CME productivity is stronger for a two-day time window for the CME production than for windows half as wide or twice as wide. This plausibly is a result of the most counterproductive active regions producing less than one CME per day, and from the active region's evolution often significantly changing the global nonpotentiality over the course of several days. These results establish that measures of active region global nonpotentiality from vector magnetograms (such as L(sub SS), I(sub N), and alpha) should be useful for prediction a active region CMEs.

Falconer, D. A.↗

NASA/GSFC Scanning Raman Lidar Measurements of Water Vapor and Cirrus Clouds during WVIOP2000 and AFWEX

The NASA/GSFC Scanning Raman Lidar (SRL) was deployed to the Southern Great Plains CART site from September - December, 2000 and participated in two field campaigns devoted to comparisons of various water vapor measurement technologies and calibrations. These campaigns were the Water Vapor Intensive Operations Period 2000 (WVIOP2000) and the ARM FIRE Water Vapor Experiment (AFWEX). WVIOP2000 was devoted to validating water vapor measurements in the lower atmosphere while AFWEX had similar goals but for measurements in the upper troposphere. The SRL was significantly upgraded both optically and electronically prior to these field campaigns. These upgrades enabled the SRL to demonstrate the highest resolution lidar measurements of water vapor ever acquired during the nighttime and the highest S/N Raman lidar measurements of water vapor in the daytime; more than a factor of 2 increase in S/N versus the DOE CARL Raman Lidar. Examples of these new measurement capabilities along with comparisons of SRL and CARL, LASE, MPI-DIAL, in-situ sensors, radiosonde, and others will be presented. The profile comparisons of the SRL and CARL have revealed what appears to be an overlap correction or countrate correction problem in CARL. This may be involved in an overall dry bias in the precipitable water calibration of CARL with respect to the MWR of approx. 4%. Preliminary analysis indicates that the application of a temperature dependent correction to the narrowband Raman lidar measurements of water vapor improves the lidar/Vaisala radiosonde comparisons of upper tropospheric water vapor. Other results including the comparison of the first-ever simultaneous measurements from four water vapor lidar systems, a bore-wave event captured at high resolution by the SRL and cirrus cloud optical depth studies using the SRL and CARL will be presented at the meeting.

Whiteman, D. N.↗

Characterization of Upper Troposphere Water Vapor Measurements during AFWEX using LASE

Water vapor profiles from NASA's Lidar Atmospheric Sensing Experiment (LASE) system acquired during the ARM/FIRE Water Vapor Experiment (AFWEX) are used to characterize upper troposphere water vapor (UTWV) measured by ground-based Raman lidars, radiosondes, and in situ aircraft sensors. Initial comparisons showed the average Vaisala radiosonde measurements to be 5-15% drier than the average LASE, Raman lidar, and DC-8 in situ diode laser hygrometer measurements. We show that corrections to the Raman lidar and Vaisala measurements significantly reduce these differences. Precipitable water vapor (PWV) derived from the LASE water vapor profiles agrees within 3% on average with PWV derived from the ARM ground-based microwave radiometer (MWR). The agreement among the LASE, Raman lidar, and MWR measurements demonstrates how the LASE measurements can be used to characterize both profile and column water vapor measurements and that ARM Raman lidar, when calibrated using the MWR PWV, can provide accurate UTWV measurements.

Ferrare, R. A.↗

Survey of Primary Flow Measurement Parameters at the NASA Langley Transonic Dynamics Tunnel

An assessment of the methods and locations used to measure the primary flow conditions in the NASA Langley Transonic Dynamics Tunnel was conducted during calibration activities following the facility conversion from a Freon-12 heavy-gas test medium to R-134a. A survey of stagnation pressure, plenum static pressure, and stagnation temperature was undertaken at many pertinent locations in the settling chamber, plenum, and contraction section of the wind tunnel and these measurements were compared to those of the existing primary flow measurement systems. Local flow velocities were measured in the settling chamber using a pitot probe. Results illustrate that small discrepancies exist between measured primary tunnel flow conditions and the survey measurements. These discrepancies in tunnel stagnation pressure, plenum pressure, and stagnation temperature were found to be approximately +/- 1-3 psf and 2-3 degrees Fahrenheit. The propagation of known instrument errors in measured primary flow conditions and its impact on tunnel Mach number, dynamic pressure, flow velocity, and Reynolds number have been investigated analytically and shown to require careful attention when considering the uncertainty in measured test section conditions.

Piatak, David J.↗

The Status of Cross Section Measurements for Neutron-induced Reactions Needed for Cosmic Ray Studies

Cosmic ray interactions with lunar rocks and meteorites produce small amounts of radionuclides and stable isotopes. Advances in Accelerator Mass Spectrometry (AMS) allow production rates to be measured routinely in well-documented lunar rocks and meteorites. These measurements are analyzed using theoretical models to learn about the object itself and the history of the cosmic rays that fell on it. Good cross section measurements are essential input to the theoretical calculations. Most primary cosmic ray particles are protons so reliable cross sections for proton-induced reactions are essential. A cross section is deemed accurate if measurements made by different experimenters using different techniques result in consistent values. Most cross sections for proton induced reactions are now well measured. However, good cross section measurements for neutron-induced reactions are still needed. These cross sections are required to fully account for all galactic cosmic ray interactions at depth in an extraterrestrial object. When primary galactic cosmic ray (GCR) particles interact with an object many secondary neutrons are produced, which also initiate spallation reactions. Thus, the total GCR contribution to the overall cosmogenic nuclide archive has to include the contribution from the secondary neutron interactions. Few relevant cross section measurements have been reported for neutron-induced reactions at neutron energies greater than approximately 20 MeV. The status of the cross section measurements using quasi-monoenergetic neutron energies at iThemba LABS, South Africa and white neutron beams at Los Alamos Neutron Science Center (LANSCE), Los Alamos are reported here.

Sisterson, J. M.↗

A Data System Architecture for Measurement Based Systems: Precipitation Processing System

NASA s Earth Science Enterprise (ESE) is changing focus from single satellite missions to measurement oriented programs. An example of this paradigm shift is the Global Precipitation Measurement (GPM) project. GPM is conceptualized as a rolling-wave of measurement possibilities all focused on the key precipitation parameter. In response to this shift to measurement programs and also integral to the ESE s new strategy for processing and management its data, a measurement based approach is also critical for data processing system that support measurement programs like GPM. This paper provides an overview of the paradigm shift from mission to measurement. It also presents a summary of the ESE s new strategy for its data systems. Building on this background the paper details the architectural, design and implementation aspects of the Precipitation Processing System (PPS). The PPS is an evolution of a single point system developed for the Tropical Rainfall Measurement Mission to a generic precipitation data system. The paper provides the context within which PPS will support the GPM program.

Stocker, Erich Franz↗

Measurement and Modeling of Vertically Resolved Aerosol Optical Properties and Radiative Fluxes Over the ARM SGP Site

In order to meet one of its goals - to relate observations of radiative fluxes and radiances to the atmospheric composition - the Department of Energy's Atmospheric Radiation Measurement (ARM) program has pursued measurements and modeling activities that attempt to determine how aerosols impact atmospheric radiative transfer, both directly and indirectly. However, significant discrepancies between aerosol properties measured in situ or remotely remain. One of the objectives of the Aerosol Intensive Operational Period (TOP) conducted by ARM in May 2003 at the ARM Southern Great Plains (SGP) site in north central Oklahoma was to examine and hopefully reduce these differences. The IOP involved airborne measurements from two airplanes over the heavily instrumented SGP site. We give an overview of airborne results obtained aboard the Center for Interdisciplinary Remotely-Piloted Aircraft Studies (CIRPAS) Twin Otter aircraft. The Twin Otter performed 16 research flights over the SGP site. The aircraft carried instrumentation to perform in-situ measurements of aerosol absorption, scattering, extinction and particle size. This included such novel techniques as the photoacoustic and cavity ring-down methods for in-situ absorption (675 nm) and extinction (675 and 1550 nm) and a new multiwavelength, filter-based absorption photometer (467, 530, 660 nm). A newly developed instrument measured cloud condensation nucleus concentration (CCN) concentrations at two supersaturation levels. Aerosol optical depth and extinction (354-2139 nm) were measured with the NASA Ames Airborne Tracking 14-channel sunphotometer. Furthermore, up-and downwelling solar (broadband and spectral) and infrared radiation were measured using seven individual radiometers. Three up-looking radiometers werer mounted on a newly developed stabilized platform, keeping the instruments level up to aircraft pitch and roll angles of approximately 10(exp 0). This resulted in unprecedented continuous vertical profiles of radiative fluxes, which we will compare to modeled fluxes using the aforementioned data as input.

Schmid, B.↗

Noninvasive, near infrared spectroscopic-measured muscle pH and PO2 indicate tissue perfusion for cardiac surgical patients undergoing cardiopulmonary bypass

OBJECTIVE: To determine whether near infrared spectroscopic measurement of tissue pH and Po2 has sufficient accuracy to assess variation in tissue perfusion resulting from changes in blood pressure and metabolic demand during cardiopulmonary bypass. DESIGN: Prospective clinical study. SETTING: Academic medical center. SUBJECTS: Eighteen elective cardiac surgical patients. INTERVENTION: Cardiac surgery under cardiopulmonary bypass. MEASUREMENTS AND MAIN RESULTS: A near infrared spectroscopic fiber optic probe was placed over the hypothenar eminence. Reference Po2 and pH sensors were inserted in the abductor digiti minimi (V). Data were collected every 30 secs during surgery and for 6 hrs following cardiopulmonary bypass. Calibration equations developed from one third of the data were used with the remaining data to investigate sensitivity of the near infrared spectroscopic measurement to physiologic changes resulting from cardiopulmonary bypass. Near infrared spectroscopic and reference pH and Po2 measurements were compared for each subject using standard error of prediction. Near infrared spectroscopic pH and Po2 at baseline were compared with values during cardiopulmonary bypass just before rewarming commenced (hypotensive, hypothermic), after rewarming (hypotensive, normothermic) just before discontinuation of cardiopulmonary bypass, and at 6 hrs following cardiopulmonary bypass (normotensive, normothermic) using mixed-model analysis of variance. Near infrared spectroscopic pH and Po2 were well correlated with the invasive measurement of pH (R2 =.84) and Po2 (R 2 =.66) with an average standard error of prediction of 0.022 +/- 0.008 pH units and 6 +/- 3 mm Hg, respectively. The average difference between the invasive and near infrared spectroscopic measurement was near zero for both the pH and Po2 measurements. Near infrared spectroscopic Po2 significantly decreased 50% on initiation of cardiopulmonary bypass and remained depressed throughout the bypass and monitored intensive care period. Near infrared spectroscopic pH decreased significantly during cardiopulmonary bypass, decreased significantly during rewarming, and remained depressed 6 hrs after cardiopulmonary bypass. Diabetic patients responded differently than nondiabetic subjects to cardiopulmonary bypass, with lower muscle pH values (p =.02). CONCLUSIONS: Near infrared spectroscopic-measured muscle pH and Po2 are sensitive to changes in tissue perfusion during cardiopulmonary bypass.

Non-NASA Center↗

Measuring sleep habits without using a diary: the sleep timing questionnaire

STUDY OBJECTIVES: To develop a single-administration instrument yielding equivalent measures of sleep to those obtained from a formal (2-week) sleep diary. DESIGN & SETTING: A single-administration Sleep riming Questionnaire (STQ) is described (and reproduced in the Appendix). Test-retest reliability was examined in 40 subjects who were given the STQ on two occasions separated by less than 1 year. Convergent validity was measured both by comparing STO-derived measures with objective measures derived from wrist actigraphy (n=23) and by comparing STQ-derived measures with other subjective measures derived from a detailed 2-week sleep diary in two nonoverlapping samples (n=101, 93). Correlations of STQ measures with age and momingness-eveningness (chronotype) were also examined. SUBJECTS: The analyses used sample sizes of 40, 23, 101, and 93 (both genders, overall age range 20y-89y). Most subjects were healthy volunteers; some Study 4 subjects were patients (enrolled in research protocols). RESULTS: Test-retest reliability for the STQ was demonstrated for estimates of bedtime (r = 0.705, p < 0.001) and waketime (r = 0.826, p < 0.001). Convergent validity using wrist actigraphy was demonstrated by correlations of 0.592 (p < 0.005) for bedtime, and of 0.769 (p < 0.001) for waketime. Diary studies indicated STQ bedtime and waketime data to be highly correlated (at about 0.8) with those obtained from a formal 2-week sleep diary. The STQ also provided data on estimated sleep latency and wake after sleep onset (WASO), which correlated reliably (at about 0.7) with average nightly ratings of these variables from a 2-week sleep diary. Mean estimated values of sleep latency and WASO from the two instruments were within 1 minute of each other. ST-derived bedtimes and waketimes correlated with both age and chronotype in the expected direction (older subjects earlier, morning types earlier). CONCLUSION: The STQ may be a reliable valid measure of sleep timing that could provide a time-efficient alternative to traditional sleep diaries.

Validation Studies↗

Forward and Backscattering Measurements of Rainfall using the NASA Microwave Link

This paper will present results from a study on the feasibility of making backscatter measurements from rainfall with the NASA/Microwave Link system at Wallops Island, VA. The study entails the implementation of an FMCW radar at the Link frequencies to enable simultaneous forward and backscatter measurements from rain. The Microwave Link system has been successfully employed in the development and testing of rainfall retrieval techniques. As presently configured, the Microwave Link measures attenuation and phase-shift due to rain over a 2.3 km path between the transmitting and receiving antennas. By their very nature, these measured quantities are averaged over the propagation path. As a result, the rainfall estimates obtained from the Link data are also averaged over the propagation path. However, rainfall is a highly variable process in space (as well as time). In order to gain a more detailed knowledge of its microphysics finer spatial resolutions are required. The backscatter measurements would enable range profiling over the Link path permitting a detailed study of the rainfall process. The backscatter measurements will be used in conjunction with the forward measurements and the measurements from a ground-based network of disdrometers and rain gauges located under the propagation path to develop new microwave retrieval techniques, and to test established single-frequency and dual-frequency radar retrieval algorithms relevant to the ongoing TRMM and up coming GPM missions.

Rincon, Rafael F.↗

Unified Model Deformation and Flow Transition Measurements

The number of optical techniques that may potentially be used during a given wind tunnel test is continually growing. These include parameter sensitive paints that are sensitive to temperature or pressure, several different types of off-body and on-body flow visualization techniques, optical angle-of-attack (AoA), optical measurement of model deformation, optical techniques for determining density or velocity, and spectroscopic techniques for determining various flow field parameters. Often in the past the various optical techniques were developed independently of each other, with little or no consideration for other techniques that might also be used during a given test. Recently two optical techniques have been increasingly requested for production measurements in NASA wind tunnels. These are the video photogrammetric (or videogrammetric) technique for measuring model deformation known as the video model deformation (VMD) technique, and the parameter sensitive paints for making global pressure and temperature measurements. Considerations for, and initial attempts at, simultaneous measurements with the pressure sensitive paint (PSP) and the videogrammetric techniques have been implemented. Temperature sensitive paint (TSP) has been found to be useful for boundary-layer transition detection since turbulent boundary layers convect heat at higher rates than laminar boundary layers of comparable thickness. Transition is marked by a characteristic surface temperature change wherever there is a difference between model and flow temperatures. Recently, additional capabilities have been implemented in the target-tracking videogrammetric measurement system. These capabilities have permitted practical simultaneous measurements using parameter sensitive paint and video model deformation measurements that led to the first successful unified test with TSP for transition detection in a large production wind tunnel.

Burner, Alpheus W.↗

In Situ Aerosol Profile Measurements and Comparisons with SAGE 3 Aerosol Extinction and Surface Area Profiles at 68 deg North

Under funding from this proposal three in situ profile measurements of stratospheric sulfate aerosol and ozone were completed from balloon-borne platforms. The measured quantities are aerosol size resolved number concentration and ozone. The one derived product is aerosol size distribution, from which aerosol moments, such as surface area, volume, and extinction can be calculated for comparison with SAGE III measurements and SAGE III derived products, such as surface area. The analysis of these profiles and comparison with SAGE III extinction measurements and SAGE III derived surface areas are provided in Yongxiao (2005), which comprised the research thesis component of Mr. Jian Yongxiao's M.S. degree in Atmospheric Science at the University of Wyoming. In addition analysis continues on using principal component analysis (PCA) to derive aerosol surface area from the 9 wavelength extinction measurements available from SAGE III. Ths paper will present PCA components to calculate surface area from SAGE III measurements and compare these derived surface areas with those available directly from in situ size distribution measurements, as well as surface areas which would be derived from PCA and Thomason's algorithm applied to the four wavelength SAGE II extinction measurements.

Source record↗

Optical Flow-Field Techniques Used for Measurements in High-Speed Centrifugal Compressors

The overall performance of a centrifugal compressor depends on the performance of the impeller and diffuser as well as on the interactions occurring between these components. Accurate measurements of the flow fields in each component are needed to develop computational models that can be used in compressor design codes. These measurements must be made simultaneously over an area that covers both components so that researchers can understand the interactions occurring between the two components. Optical measurement techniques are being used at the NASA Lewis Research Center to measure the velocity fields present in both the impeller and diffuser of a 4:1 pressure ratio centrifugal compressor operating at several conditions ranging from design flow to surge. Laser Doppler Velocimetry (LDV) was used to measure the intrablade flows present in the impeller, and the results were compared with analyses obtained from two three-dimensional viscous codes. The development of a region of low throughflow velocity fluid within this high-speed impeller was examined and compared with a similar region first observed in a large low-speed centrifugal impeller at Lewis. Particle Image Velocimetry (PIV) is a relatively new technique that has been applied to measuring the diffuser flow fields. PIV can collect data rapidly in the diffuser while avoiding the light-reflection problems that are often encountered when LDV is used. The Particle Image Velocimeter employs a sheet of pulsed laser light that is introduced into the diffuser in a quasi-radial direction through an optical probe inserted near the diffuser discharge. The light sheet is positioned such that its centerline is parallel to the hub and shroud surfaces and such that it is parallel to the diffuser vane, thereby avoiding reflections from the solid surfaces. Seed particles small enough to follow the diffuser flow are introduced into the compressor at an upstream location. A high-speed charge-coupled discharge (CCD) camera is synchronized to the laser pulse rate; this allows it to capture images of seed particle position that are separated by a small increment in time. A crosscorrelation of a particle's position in two consecutive images provides an estimate of flow velocity and direction. Multiple image pairs obtained in rapid succession at a particular flow condition provide enough measurements for statistical significance. PIV provides simultaneous velocity measurements over the entire plane that is illuminated by the light sheet instead of at a single point, as is the case when LDV is used. PIV has a further advantage in that the laser light pulse can be triggered by an external source such as a high-response pressure transducer. This feature will allow PIV to synchronize flow imaging to physical phenomena such as rotating stall or stall precursor waves. We hope that this technique can be used to obtain images of the flow field during and just prior to stall.

Skoch, Gary J.↗

A Wireless Fluid-Level Measurement Technique

This paper presents the application of a recently developed wireless measurement acquisition system to fluid-level measurement. This type of fluid-level measurement system alleviates many shortcomings of fluid-level measurement methods currently being used, including limited applicability of any one fluid-level sensor design. Measurement acquisition shortcomings include the necessity for power to be supplied to each sensor and for the measurement to be extracted from each sensor via a physical connection to the sensor. Another shortcoming is existing measurement systems require that a data channel and signal conditioning electronics be dedicated to each sensor. Use of wires results in other shortcomings such as logistics needed to add or replace sensors, weight, potential for electrical arcing and wire degradations. The fluid level sensor design is a simple passive inductor-capacitor circuit that is not subject to mechanical failure that is possible when float and lever-arm systems are used. Methods are presented for using the sensor in caustic, acidic or cryogenic fluids. Oscillating magnetic fields are used to power the sensor. Once electrically excited, the sensor produces a magnetic field response. The response frequency corresponds to the amount to fluid within the capacitor s electric field. The sensor design can be modified for measuring the level of any fluid or fluent substance that can be stored in a non-conductive reservoir. The interrogation method for discerning changes in the sensor response frequency is also presented.

Woodard, Stanley E.↗

Checking Contamination during Storage of Carbonaceous Chondrites for Micro FTIR Measurements

We examined organic contamination by Fourier transform infrared micro spectroscopic (micro FTIR) measurements of carbonaceous chondrite samples. Carbonaceous chondrites, Tagish Lake (C2), Murchison (CM2) and Moss (CO3), and some mineral powder samples pressed on aluminum plates were measured by micro FTIR before and after storage in several containers with silicone rubber mat. During storage, samples did not touch directly anything except the holding aluminum plates. The carbonaceous chondrites containing hydrous minerals (Tagish Lake and Murchison) pressed on aluminum plates and measured by transmission-reflection micro FTIR measurements were found to be contaminated during storage after only one day, as revealed by an increase of approximately 2965 /cm and approximately 1260 /cm peaks. The Moss meteorite which contains no hydrous minerals, did not show an increase of these peaks, indicating no organic contamination. This difference is probably related to the differing mineralogy and physical properties (including porosity and permeability) of these chondrites. Hydrous minerals such as antigorite, muscovite, montmorillonite and silica gel showed organic contamination by the same infrared measurements, while anhydrous materials such as SiO2 and KBr showed no contamination. These results indicate importance of surface OH groups for the organic contamination. Organic contamination was found on silica gel samples pressed on aluminum plates when they were stored within containers including silicone rubber, silicone grease or adhesive tape. Long path gas cell FTIR measurements for silicone rubber indicated methylsiloxane oligomers were released from the silicone rubber. In-situ heating infrared measurements on the contaminated antigorite and Tagish Lake showed decrease of the 1262 /cm (Si-CH3) and 2963 /cm (CH3) peaks from room temperature to 200-300 C indicating desorption of volatile contaminants. These results indicate that careful preparation and storage are essential for FTIR measurements on precious astromaterial samples such as meteorites, IDPs and samples returned from comets, asteroids and Mars. Every possible contamination source should be evaluated before anything is done to these samples.

Zolensky, Michael E.↗

Simultaneous Temperature and Velocity Measurements in a Large-Scale, Supersonic, Heated Jet

Two laser-based measurement techniques have been used to characterize an axisymmetric, combustion-heated supersonic jet issuing into static room air. The dual-pump coherent anti-Stokes Raman spectroscopy (CARS) measurement technique measured temperature and concentration while the interferometric Rayleigh scattering (IRS) method simultaneously measured two components of velocity. This paper reports a preliminary analysis of CARS-IRS temperature and velocity measurements from selected measurement locations. The temperature measurements show that the temperature along the jet axis remains constant while dropping off radially. The velocity measurements show that the nozzle exit velocity fluctuations are about 3% of the maximum velocity in the flow.

Danehy, P. M.↗

An Instrument to Enable Identification of Anthropogenic CO2 Emissions Using Concurrent CO Measurements

We have developed an instrument concept that will enable the measurement of CO from the top of the atmosphere to the Earth's surface with very high sensitivity and at the high spatial and temporal resolutions required by the NRC Decadal Survey mission Active Sensing of Carbon Dioxide (CO2) over Nights, Days and Seasons (ASCENDS). We are developing an innovative CO sensor that will enable the ASCENDS mission to differentiate between anthropogenic and natural sources and sinks of global carbon. The NRC Decadal Survey places particular emphasis on retrieving CO information for the planetary boundary layer. Measurement made using both the 2.3 micron and 4.7 micron channels are needed to achieve the sensitivity required in the lower atmosphere where the degree of CO - CO2 correlation is indicative of anthropogenic sources of CO2. Measurements made using only the 4.7 micron channel cannot provide sufficient sensitivity to CO in the very lowest layers of the atmosphere. The fundamental method we use is Gas Filter Correlation Radiometry (GFCR), a highly successful technique used in other airborne and space-based missions for detecting trace species in the Earth's atmosphere. Our version of GFCR overcomes many of the limitations encountered by prior and existing instruments, allowing us to measure weak signals from small targets very quickly and with extremely high specificity by employing a new dual beam radiometer concept using a focal plane array. Our design will provide a means to make the desired CO measurements for the ASCENDS mission. A simple change in gas filter cell contents would allow the same hardware to measure CH4 with high precision under the nominal ASCENDS mission spatial and temporal constraints. All critical components in the sensor design are mature, many subsystems tested, and the system has been extensively modeled, bringing it to a present Technology Readiness Level (TRL) of 3 (though some individual components are at TRLs 6-9). We are presently developing critical components for the new spectrometer and advancing our understanding of the measurement requirements for both CO and CH4. This new GFCR technique/sensor will enable measurements of trace gases with high sensitivity while maintaining the inherent robustness and simplicity of the more traditional radiometer hardware. Initial estimates of cost/risk of a spacebased 2-channel GFCR indicate that our design is extremely cost effective and will fit within existing ASCENDS mission budget constraints as determined by the NRC Decadal Survey and a NASA-sponsored mission study.

Cook, William B.↗