Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “mcnp”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 847 records · Page 47

Multigroup Neutron Cross Section Generation for the SCEPTRE Code

Multigroup neutron cross sections were generated for the deterministic radiation transport code SCEPTRE. ENDF/B-VII.1 nuclear data files were downloaded from Los Alamos National Laboratory (LANL), processed with the LANL cross-section preparation code NJOY-2012, and post-processed to produce a SCEPTRE-formatted cross section file. A simple radiation transport problem was used to compare results calculated with MCNP, a continuous-energy radiation transport code from LANL, to results calculated with SCEPTRE using the NJOY-2012-produced multigroup cross sections. This problem was used to debug the python scripts used to post-process the NJOY-2012 output and to assess the accuracy of the multigroup cross sections. These comparisons demonstrate that the multigroup cross sections generated in this work are accurate for most elements but yielded inaccurate results for several common transition metals. This discrepancy appears to result from poor treatment of the resolved resonance region of the continuous-energy cross sections. Further work is recommended to investigate alternative methods to treat these resonances with NJOY-2012.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Neutron Activation Self-Shielding Factors for Common Dosimetry Foils in an ACRR Equivalent Environment

The results of a computational analysis of self-shielding factors are presented. The analysis highlights the total self-shielding, which is a combination of energy and spatial self-shielding, associated with different neutron detection materials. The Monte Carlo N-Particle (MCNP) transport code was used in conjunction with the Evaluated Nuclear Data File (ENDF) and the International Reactor Dosimetry and Fusion Files (IRDFF). This analysis was done with neutron activation analysis in mind, and therefore is modeled and presented in a similar fashion.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Total Measurement Uncertainty in Neutron Coincidence Multiplicity Analysis

Neutron multiplicity counting is the most commonly used nondestructive assay technique for determining the plutonium mass within containers of scrap PuO 2 or mixed oxide (MOX). In multiplicity analysis, the 240 Pu eff mass, leakage multiplication, and alpha ratio (the ratio of [α, n]-to-spontaneous fission neutron production) are the three primary unknown sample properties. They must be determined simultaneously. To solve for these three unknowns in a multiplicity assay, three measured values are needed: the singles, doubles, and triples neutron count rates. While the analysis is limited to solving for three unknowns, there are many additional factors that impact the observed count rates and contribute to the measurement uncertainty. In this study we investigate the various uncertainty contributors for the multiplicity analysis through a combination of traditional uncertainty propagation techniques supplemented by Monte Carlo simulations to address the dependences not explicitly expressed by the point source model. Uncertainties arising from counting statistics, calibration parameters, calibration method, nuclear data, and various material characteristics (isotopic abundances, chemical form, density, and impurities) are considered. A Total Measurement Uncertainty (TMU) estimate is then developed from these uncertainty contributors. This study is confined to multiplicity analysis of items commonly encountered in international safeguards applications. That is, the study focused on Pu oxides and MOX materials for the masses ranging up to 4000 grams total Pu. Multiplicity measurements were simulated using MCNP V6 based on the Plutonium Scrap Multiplicity Counter (PSMC), Epithermal Multiplicity Counter (ENMC), Pyrochemical Multiplicity Counter, and Large Epithermal Multiplicity Counter (LEMC) for this study; however, this report focuses on the parameterization of the uncertainties for the PSMC. The performance differences between the PSMC and the other multiplicity counting systems are relatively small, primarily manifesting in the impact on measurement precision so that the evaluation developed for the PSMC can be applied to the other multiplicity counting systems. Finally an analysis tool, the Multiplicity TMU Estimator, was developed from this study to serve as an aid for evaluation of the total measurement uncertainty of multiplicity assay results obtained from the commonly used INCC acquisition and analysis software.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Calculated Gamma Output from a 6-kilogram Sphere of Neptunium

We previously modeled a 6 kg neptunium sphere with pyDMTK 2.0.0b, a python-based intrinsic radiation (INRAD) modeling tool, on the MOONLIGHT machine. Here we report results from version 2.0.1b on SNOW, another TriLab Linux Capacity Cluster (TLCC) resource on the Laboratory’s Turquoise network. We also present gamma output from MCNP 6.2.0 in terms of discrete line strengths, full gamma spectra, and dose rate maps for visualization. Results from both models agree with recent gamma measurements.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Performance Demonstration of Self-Powered Neutron Detectors for Steady-State Reactor Operations

The irradiation testing of sensors in reactors is a crucial step towards calibrating and qualifying sensors prior to their deployment in experiments. This report details the process toward qualifying and calibrating custom-designed rhodium-based self-power neutron detectors (Rh-SPNDs) for steady-state reactor irradiations. This process serves to both demonstrate the performance capabilities of Rh-SPNDs as well as to provide experimental data for development of a sensor sensitivity model. Two designs of Rh-SPNDs were tested in various reactors to demonstrate: detection resolution in a low neutron flux environment, a delayed-response compensation technique, output linearity in a large range of neutron flux, and measurement accuracy verified with dosimetry. The detection resolution and compensation technique was demonstrated in the AGN-201m reactor at Idaho State University. The irradiation confirmed the sensors’ capability to perform steady-state operations in a low neutron flux of ~2E8 n/cm 2 -sec. Sensor output linearity coupled with the delayed-response compensation was investigated at the neutron radiography reactor at Idaho National Laboratory. A Rh-SPND was irradiated to neutron fluxes ranging from 2E8 to 2E13 n/cm2-sec range. The measured data demonstrated a wide and linear range of operation with a measured linear sensitivity of 1.0129 ×10 -13 A/W with a correlation-squared value of r 2 =0.9927. The measurement accuracy was investigated at the Advanced Test Reactor Critical reactor. The SPNDs were inserted into a test vehicle with collocated flux wires. Two irradiations with different flux levels were performed, and the SPNDs relative measurement between the two irradiations was calculated to be 1.2613 ± 0.0153 for the small SPND design and 1.1809 ± 0.0108 for the large SPND design. Both SPND measurements fell between the co-axial dosimetry result, which reported 1.218 ± 0.047. Additionally, the preliminary MCNP model for calculating SPND sensitivity was developed in parallel to this work. Modeled neutron spectrum with measured magnitude was used for inputs to determine the simulated SPND output. The results showed an overestimation of signal strength by a factor of 5, which was expected because of model simplification. This leads to future modeling work to account for signal losses from additional physical properties, including high temperature environments for FY-21.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Radiation Transport Simulation of the Sulfur Counting System in the Radiation Metrology Laboratory (RML)

At the request of staff members from the Radiation Metrology Laboratory (RML), a series of Monte Carlo radiation transport calculations were performed using two different models of the detector geometry of the RMLs sulfur counting system. The fraction of electrons from each β-decay of 32 P in the sulfur pellet that enter the window of the sulfur counting system was calculated with both MCNP and ITS. In addition, the differential energy distributions of the electrons entering the counting system window were computed. There was significant agreement between the integral and differential quantities calculated by the two transport codes. Summary tables are for the integral efficiency values are found in the body of the report.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Proof that Combining the Forced-collision and DXTRAN Monte Carlo Variance-reduction Techniques is Fair

This report provides mathematical proof that the MCNP DXTRAN (also known in other codes as forced-flight) and forced-collision variance-reduction techniques do not bias the expected value of Monte Carlo simulation estimates when combined. Proof is also provided that the techniques are unbiased when used independently. To prove that the techniques are unbiased, this report derives the first History Score Moment Equation (HSME) for non-multiplying media employing only forced collisions, only DXTRAN, and then both the variance-reduction techniques combined, as defined next. The HSMEs are found by forming the History Score Probability Density Functions (HSPDFs) and then taking the first score moment. Following its derivation, each HSME with a variance-reduction technique employed is reduced to the HSME for an analog simulation. Because the HSME represents the expected contribution to estimators in the simulation, reducing the HSME with variance reduction to the analog HSME shows that the simulation is unbiased despite the variance-reduction technique considered in the HSME. Analysis regarding higher-score moments of each technique is the subject of prior work and is not addressed herein. Throughout this work, the phase space p is defined to be the particle position x, direction-of-flight unit vector $\hat{Ω}$, energy E, and statistical weight w, $$p ≡ (x; \hat{Ω}; E; w).$$ A reduced phase-space excluding the statistical weight of the particle, $$r ≡ (x; \hat{Ω}; E),$$ is also used.

97 MATHEMATICS AND COMPUTING↗

Verification of Combined VR Techniques, Derivation of Future Time Equation, and Integration of LLNL Pulsed Sphere V&V Suite [Slides]

To determine whether the combination of forced-collision and DXTRAN variance-reduction (VR) techniques is unbiased, and to gain insight into the operation of these techniques, proof that first-moment estimates from Monte Carlo simulations employing both techniques are unbiased is developed. A general background on the forced-collision and DXTRAN VR techniques and their combination is given. Proof of an unbiased simulation is outlined by showing the equivalence of the history score moment equations of simulations with these techniques in use. A report with detailed proof of this equivalence is available upon request. The derivation of the future time equation using a similar approach, as well as a summary of the addition of the LLNL Pulsed Sphere experiments to the MCNP verification and validation suite, is also briefly discussed.

97 MATHEMATICS AND COMPUTING↗

Neutron Transmission Imaging with a Portable D-T Neutron Generator

Fast-neutron transmission imaging provides complementary information to x-ray transmission imaging. While fast neutron imaging resolution is generally below x-ray imaging, 14-MeV neutrons have an advantage over portable x-ray systems. Neutrons have higher transmission through high-Z materials due to a more uniform attenuation as a function of material atomic number Z compared to X-rays, and can therefore image low-Z materials inside high-Z materials. As a result, portable neutron transmission imaging has many applications, including inspection of concrete and welds for corrosion in vehicles, bridges, and other infrastructure, measurement of material levels in containers, and inspection of suspicious packages. Fast-neutron imaging is also more practical for field use than thermal-neutron imaging due to the size and shielding requirements typical of thermal-imaging systems compared to the availability of small 14.1 MeV D-T neutron generators. However, there are limitations in portable fast-neutron imaging systems, including limited neutron output, limited light produced by neutron scintillators, and lower resolution due to neutron source spot size and 2-3 mm scintillator thickness. In addition, digital-panel dark-noise is roughly 100x higher than neutron scintillator light, and variations in noise across the panel and in time is comparable to the imaging signal. Here we discuss recent efforts in developing a portable fast-neutron radiography system, including an improved neutron scintillator, mitigation of panel noise, and new commercial portable D-T neutron generators. We also present MCNP efforts to model neutron imaging, including scintillator resolution and the effects of neutron scattering from the object and surrounding materials.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

ECAR 4951 BSU-8242 3 DPA As-Run Physics Analysis

The purpose of this report is to document the as-run physics analysis for the Boise State University (BSU-8242) experiment in the A6, A7 and A8 positions, correlating with the 3 DPA specimens irradiated in Cycles 164A, 164B, and 166A. In this paper the heat rate, flux, fluence, and DPA for all specimens are scaled to the appropriate as-run lobe powers for an accurate assessment and description of the irradiated materials. Source terms per capsule are provided, and a bounded source term per specimen type is given on a per gram basis. Verified and validated MCNP full-core models were used for the neutronics analysis.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

DRiFT - Release 1.0.0 Organic Scintillators

DRiFT (a Detector Response Function Toolkit) is LANL-developed software that postprocesses output from the extensively validated radiation transport code, MCNP [1], and generates realistic nuclear instrumentation response. DRiFT is designed to be flexible, enabling users to specify detector type and many experimental settings, as well as accommodating the addition of their own desired features. Although DRiFT development has included scintillator [2], gas [3], and semiconductor features [4], the focus of this release is on organic scintillator and associated capabilities. Organic scintillators are widely used in the areas of nuclear safeguards and nuclear non-proliferation efforts [5, 6]. DRiFT has several diagnostic and detector physics features relevant to detailed scintillator simulations including: tracking source particle information, scintillation light production, the effects of PMT quantum efficiency and gain, and digitizer settings. Users can select responses from many scintillator and PMT types supported natively by DRiFT, or add their own by following the instructions in this document. We acknowledge that DRiFT is under active development, bug reports and general questions and comments should be directed to Madison Andrews, madison@lanl.gov. This manual is divided into four parts: I) An overview of DRiFT, including how to obtain and install the executable, II) A description of the detector physics related to scintillators available, III) a description of more general DRiFT features the user may find useful, and IV) a description of the test suite and examples made available with the code release.

61 RADIATION PROTECTION AND DOSIMETRY↗

Mini minutes for a mini CSEWG Virtual mini-CSEWG Meeting 16-19 August, 2021

This meeting is a collaboration meeting of the Cross Section Evaluation Working Group (CSEWG), a collaboration including members from various DOE NNSA and non-NNSA laboratories as well as several university groups that support these laboratory missions. The focus of this meeting will be preparations for the next major release of the ENDF/B nuclear data library. The ENDF/B library is the main neutronics library used in various US neutronics codes such as MCNP and SCALE for advance reactor work, safeguards, stockpile stewardship, etc.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

External Release of Organic Scintillator DRiFT Software - Technology Evaluation and Demonstration Project Accomplishments [Slides]

Overview and Objectives: DRiFT post processes radiation transport output from MCNP, and generates realistic nuclear instrumentation response; Organic scintillator response has been developed, tested, and validated with measurements, these instruments are widely used in nuclear safeguards. At the beginning of this project, DRiFT was only available to LANL employees with access to yellow High Performance Computing clusters. Additionally, there are many complicated external software dependencies. Our TED project request proposed using funds to: Comment and clean up code, friendly testing, generating test suites and examples; Expansion of scintillator types natively supported by DRiFT; External release of DRiFT accompanied by documentation. We accomplished all objectives (and many others), they are highlighted in these slides.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Recent MCNP6 ® Code Developments and Improvements for Nuclear Engineering Applications [Slides]

The Los Alamos MCNP Monte Carlo radiation transport code has been the international gold standard for particle transport applications for over three decades. Many developments to the code have taken place with several significant new feature additions, major improvements, and enhancements to existing features. With significant institutional and programmatic investment in the code since the time of the last public release in 2018, important code development and infrastructure modernization has taken place and remains a high priority for all ongoing efforts across the code development team.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

TNSL Overview

Thermal neutron scattering law (TNSL) data describe low-energy neutrons scattering off of bound materials, and can have a significant impact on modeling any system with slow neutrons, including nuclear reactors. Previous work to introduce TNSL data to neutron transport codes at LLNL focused on COG and TART [1], with the limitation that these codes require highly specialized data processing and formatting. We have recently increased efforts to process TNSL data with the central LLNL nuclear data processing code FUDGE, to be stored in the generalized nuclear database structure (GNDS) for use in any general transport code with the ability to read GNDS data. The first step in this effort is to verify that the TNSL processing with FUDGE yields results comparable to results obtained using the LANL nuclear data processing code NJOY. The next step is to verify the transport of thermal neutrons in Mercury (a Monte Carlo code) and Ardra (a deterministic code) against one another, as well as against the LANL Monte Carlo neutron transport code MCNP. This verification step has not been completed, due to a number of discrepancies between results obtained using differently processed data. There is ongoing effort to understand differences between FUDGE and NJOY. Finally, we map out our current capability to validate TNSL data against benchmark systems.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

As-Run Physics Analysis for the EPRI Zirconium Growth C Capsule

This engineering calculation and analysis report documents the as-run nuclear-heating term, source-term, and radiation damage (measured in displacements per atom [dpa]) accumulation for the Electric Power Research Institute zirconium growth experiment's C capsule (EPRI-ZG-C). These data have been calculated using MCNP 6.1 and SCALE 6.2.3. These data can be used for: the shipping of the EPRI-ZG-C capsule, the acceptance of the capsule at the Materials and Fuels Complex, and programmatic scientific needs.

36 MATERIALS SCIENCE↗

Radiation Damage Calculation Methodology

This report outlines the consensus radiation damage calculation methodology used by the Neutronics Analysis Group at Idaho National Laboratory. This methodology includes calculation of radiation damage rates via the Monte Carlo N-Particle (MCNP) code, and calculation of radiation damage in mixed materials, such as alloys. A consistent method for calculating the average displacement threshold energy of a mixed material has been established by the Neutronics Analysis Group. No standard method currently exists to account for radiation damage caused by neutron-induced transmutations. Only one documented case addresses transmutation radiation damage in materials containing nickel, and that method was incorporated by the Neutronics Analysis Group into their radiation damage calculation methodology.

36 MATERIALS SCIENCE↗