A Review of TSUNAMI Applications

The TSUNAMI-1D and TSUNAMI-3D sequences for generating k eff sensitivity coefficients were first released in SCALE 5 in 2004. Several other tools were introduced in the same release, including primarily the TSUNAMI-IP code for uncertainty analysis and similarity assessments. The TSUNAMI sequences added capabilities for identifying important reactions and data for systems using sensitivity coefficients and also introduced new quantitative tools for rigorously assessing the similarity of systems. Over time, the capabilities of these tools have grown, and their use has expanded into other areas such as nuclear data assessment and nuclear covariance data testing. This paper discusses applications of the TSUNAMI tools for sensitivity calculations, sensitivity/uncertainty (S/U)-based validation, and nuclear data testing. This paper is one of a series of papers at this conference on the development and use of TSUNAMI tools. The other papers address the development of the TSUNAMI methods and the use of TSUNAMI for critical experiment design and optimization.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Bayesian Monte Carlo Evaluation Framework for Cross Sections Nuclear Data and Integral Benchmark Experiments

The new Bayesian Monte Carlo (MC) evaluation framework described in this abstract has been conceived as an attempt to improve nuclear data evaluations of differential crosssection data by removing the following two approximations conventionally employed for nuclear data evaluations: all probability density functions (PDFs) of all data and model parameters, both prior and posterior, are assumed to be normal (i.e., Gaussian) PDFs, and all uncertainties and covariances are propagated using a linear approximation. With these approximations removed, the Bayesian MC (BMC) framework could be used to account for nonlinear effects and would enable improved evaluations of differential cross sections and IBE data that are presently performed based on the assumptions itemized above. The BMC would also improve upon the uniform sampling of IBE parameters from within ranges defined by their evaluated uncertainties.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

S/U Comparison Study with a Focus on USLs

Under a DOE Nuclear Criticality Safety Program (NCSP) task involving Analytical Methods, three Laboratories collaborated in a comparison of results obtained from Sensitivity/Uncertainty (S/U) packages relevant to validation of transport codes. The task involves Institut de Radioprotection et de Sûreté Nucléaire (IRSN), Los Alamos National Laboratory (LANL), and Oak Ridge National Laboratory (ORNL) comparing results of MORET 5/MACSENS V3.0, MCNP6.2/Whisper-1.1, and SCALE 6.2.3/TSUNAMI/USLSTATS respectively. All Monte Carlo transport code results utilize ENDF/B-VII.1. Four cases from the International Handbook of Evaluated Criticality Safety Benchmark Experiments (ICSBEP Handbook) were selected as application models: HEU-MET-FAST-013-001, HEU-SOL-THERM 001-008, PU-MET-FAST-022-001, and PU-SOL-THERM 001-001. Ultimately, comparison is made between Upper Subcritical Limits (USLs) obtained using each code package for each application case. Since differences exist in whether packages take into account margin of subcriticality (MOS), the USL may be computed using bias and bias uncertainty, also known as the calculational margin (CM) in ANSI/ANS 8.24. Application of portions of MOS to the USL for nuclear data uncertainty of and potential code margin is referred to as USL herein. In either case, additional MOS is considered for actual application cases.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Subcritical Multiplication with a Fixed Source

In a subcritical, multiplying medium, the system multiplication describes the expected total number of neutrons created by a single source neutron. Subcriticality plays a large role in criticality safety and thus it is vital for the subcritical multiplication factor be accurate, especially as a system approaches criticality. This work examines the accuracy of calculating the system multiplication using the MCNP6.2 ® k-eigenvalue power iteration (KCODE) method when a fixed-point source is present in a multiplying medium, for near critical systems. This work compares the standard approach for calculating system multiplication, using the fixed-source calculational approach, to a new, single k-eigenvalue power iteration approach that incorporates a fixed-source component and a fission-source component into a single calculation. For the remainder of this paper, some theoretical background and numerical results for an approximate k eigenvalue approach, an accurate fixed-source approach and a new and more accurate k-eigenvalue approach to computing system multiplication are provided.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Validation of MCNP Critical Benchmark Models of PU-MET-FAST-016

A new centralized repository of high-quality MCNP models of critical benchmark experiments is currently under development at Los Alamos National Laboratory (LANL). The repository is the combined effort of the Nuclear Criticality Safety, Nuclear Data, and Monte Carlo code development/application organizations at LANL. The initial set of benchmark models in the repository are derived from the Whisper Suite provided with MCNP6.2 and are evaluated against the benchmark experiments described in the International Criticality Safety Benchmark Evaluation Project (ICSBEP) Handbook. The goal is to build a single LANL benchmark collection that is up to date with the latest ICSBEP revision, has a formal review and revision process, is contained in an open-source repository, and utilizes new Python tools for improved input and output file review. This paper describes the validation of the models associated with PU-MET-FAST-016, “Flooded 3X3X3 Arrays of 3-kg Plutonium (Pu) Metal Cylinders – Phase I”. In this critical experiment, twenty-seven 3-kg Pu metal cylinders with a height of 46.33 ± 0.15 mm and diameter of 65.25 ± 0.05 mm were arranged in a cubic array. The Pu cylinders were sealed in aluminum cans, and three cans were placed in each of nine perforated aluminum sleeves, as shown in Fig. 1. The nine sleeves were supported by an aluminum frame that allowed for control of the lateral spacing of the cylinders, both in the X and Y directions. The benchmark experiment measured thirteen configurations. Of these configurations, six were modeled using MCNP.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Sensitivity Calculations for Systems with Polyethylene Reflector Materials Using CLUTCH

The SCALE 6.2.4 code package contains four sequences for calculating $k_{eff}$ sensitivity coefficients. Two of these sequences use deterministic transport solvers: a one-dimensional (1D) capability based on XSDRN, and a two-dimensional (2D) capability based on NEWT. These sequences are restricted to the multigroup (MG) treatment of neutron energy. The three-dimensional (3D) sequences use the KENO V.a or KENO-VI Monte Carlo transport codes and can be used to calculate sensitivity coefficients with either MG or continuous-energy (CE) transport. The 3D sensitivities are ultimately reported in an MG structure, regardless of the method used in the transport calculations. If desired, the sensitivity coefficients can be reported with very fine energy resolution from a CE calculation, but they are calculated only in the MG library structure in the MG mode. CE TSUNAMI methods are available in SCALE starting in SCALE version 6.2. Sensitivity coefficients were generated using the 3D sequences as part of the generation of the SCALE 6.2.2 Validation Report; difficulties encountered when using the CLUTCH method for thick, fissionable-material reflectors were discussed and investigated as documented in a previous paper. This paper discusses the difficulties encountered in generating accurate sensitivity coefficients using the CLUTCH technique for polyethylene reflectors for two fast spectrum benchmarks. Direct perturbation (DP) calculations were performed to confirm the accuracy of the total sensitivity coefficient for important isotopes with large sensitivities in the system. Discrepancies were detected for CLUTCH-calculated sensitivity coefficients in the reflector of a critical experiment with a radial polyethylene reflector. A simple polyethylene-reflected plutonium sphere was then used to further investigate the discrepancy. Calculations performed using the iterated fission probability (IFP) method generated accurate sensitivity coefficients in both cases. The results of this study emphasize the need to confirm CLUTCH sensitivity results with DP calculations. IFP calculations are generally less efficient but more reliable than CLUTCH calculations. Improvements to the CLUTCH methodology that retain the greater efficiency but address identified difficulties are therefore potentially useful to analysts.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Discovery of AMPX Thermal Scattering Law Processing Issue for Solid Moderators

The 2020 edition of The International Criticality Safety Benchmark Evaluation Project (ICSBEP) Handbook includes a newly produced plastic-moderated evaluation, identified as PU-MET-MIXED-002 and referred to as PMM002. The 2021 edition should include another new plastic-moderated experiment, HEU-MET-THERM-004, referred to as HMT-004. These evaluations are of particular interest, as PMM-002 is moderated with polyethylene, and HMT-004 is moderated with polymethyl methacrylate (Lucite), allowing for investigation of the differences in the thermal scattering laws (TSLs) available for these materials. ENDF/B-VIII.0 includes newly produced data for 1 H-based scattering materials, including Lucite and yttrium hydride. Other available 1 H TSLs include polyethylene, light water, zirconium hydride. The unbound 1 H (free-gas) cross sections were also used. ENDF/B-VIII.0 also includes revisions made to the ENDF/B-VII.1 light water and polyethylene evaluations. Zirconium hydride was unchanged from ENDF/B-VII.1. As of this writing, there are no benchmarks included in the Verified, Archived Library of Inputs and Data (VALID) that are primarily moderated with any solid moderator, so validation that includes the PMM-002 and HMT-004 evaluations would expand the coverage to two new moderators. A study was undertaken at Oak Ridge National Laboratory with two purposes: to provide validation data based on systems that are primarily moderated with polyethylene and Lucite, and to demonstrate the reactivity changes that can result from use of different 1 H TSLs in these plastic-moderated systems. The first objective was mainly to test data and code for SCALE and AMPX, whereas the second objective was to provide useful data for practitioners on the potential variability of predicted $k_{eff}$ based on TSL changes. The use of an exactly correct TSL is often not possible given the materials involved (e.g., lubricants), but this study was intended to provide some indication of the magnitude of the changes among similar materials that can manifest through application of different TSLs in hydrogenous systems over a range of different neutron energy spectra. Unfortunately, the nominal $k_{eff}$ results exposed deviations between SCALE and Monte Carlo N-Particle (MCNP). Some of the results using different TSLs were also unexpected and difficult to explain. An investigation revealed a processing issue in AMPX that was caused by an ambiguous description of the data for incoherent elastic scattering in the ENDF manual. This issue is discussed in detail in a SCALE User Notification, and it affects some solid moderators, but it does not apply to 1 H bound in water. This issue highlights the importance of validating all TSLs used in safety analysis calculations. The remainder of this paper provides a more detailed examination of the results that triggered the investigation and a summary of the findings of that investigation.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Hierarchical Data Format for Nuclear Data Sensitivities

The SCALE code system includes capabilities for sensitivity and uncertainty (S/U) analysis as part of its TSUNAMI code suite. The sensitivity of a quantity of interest (for example, an application’s $k_{eff}$) to nuclear data is stored as a profile in a text-based file, which is known as a sensitivity data file (SDF). The sensitivity profile can be used to calculate uncertainties, correlation coefficients, and similarity indices. One of the goals of the present work was to seek general performance improvements in the TSUNAMI code suite, starting with the TSUNAMI-IP code for calculating similarity indices. Through profiling, it was found that reading the text-based sensitivity files was a performance bottleneck in the TSUNAMI-IP code. In a typical TSUNAMI-IP calculation, an application might be compared to thousands of benchmarks, thus requiring the reading of thousands of SDFs. Reading of binary-based data is generally faster than reading text-based data. Hierarchical Data Format 5 (HDF5) is a binary-based format that also benefits from being portable, and it can be inspected with nonproprietary tools. This paper describes an HDF5-based file format that has been introduced for SDFs.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Investigation of Delayed Neutron Sensitivities for Several ICSBEP Benchmarks using MCNP

The effective delayed neutron (β$_{eff}$) is a very important parameter for reactor and criticality applications. This parameter is equal to the difference in reactivity between delayed critical ($k_{eff}$ = 1, which requires both prompt and delayed neutrons to achieve criticality) and prompt critical ($k_p$ = 1, which requires only prompt neutrons to achieve criticality). This is often referred to as the delayed critical "window" (the region of criticality between delayed and prompt critical). β$_{eff}$ is a reactor kinetics parameters and depends on the nuclides in the system that undergo fission as well as the spectral characteristics of the system. Measurements of β$_{eff}$ have been performed for many criticality experiments. The EUCLID (Experiments Underpinned by Computational Learning for Improvements in nuclear Data) project at Los Alamos National Laboratory (LANL) aims to constrain nuclear data by using a suite of measurement types beyond $k_{eff}$. Our team has recently investigated the use of pulsed spheres for nuclear data validation. Several other measurement methods are also of interest, including β$_{eff}$ (investigated here) and reactivity coefficients (investigated in a separate work at this same meeting). One focus of our work is to determine if other methods are complimentary to the critical experiments already utilized for nuclear data validation. This is important because if a method has similar sensitivities then it will not be particularly useful for nuclear data validation as it will provide the same information as the critical experiments already being used. Here "similar" could refer to several characteristics, one being the shape of a sensitivity profile over energy. In the future, these methods will be utilized (with both existing and new experiments) in machine learning algorithms for nuclear validation, similar to what is currently done for criticality experiments. In order to use a measurement type for nuclear validation, it is necessary to obtain cross-section sensitivities for that parameter. This work looks at one approach to estimate β$_{eff}$ sensitivities by utilizing $k_{eff}$ sensitivities within Monte Carlo N-Particle ® Code Version 6.2. This is applied to several criticality benchmarks. Results are compared and the benefits and limitations of this approach are discussed.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Comparison of NMC estimates with trans-stilbene, EJ-309, and He-3 detection systems

Neutron multiplicity counting (NMC) is a technique for the assay of fissile material. In this work, three detection systems are utilized for active interrogation assay of shells of the Rocky Flats shells (highly enriched uranium, 93% 235U) stacked from 13.25-54.92 kg assemblies. The singles ($R_1$) and doubles ($R_2$) rates are calculated with each system to estimate two sample parameters: $M_L$- the leakage multiplication and F - the sample fission rate. The estimated mass, m, is found by dividing F by a constant activity per unit mass. Since we are interrogating HEU, the α ratio of (α; n) to fission neutrons is taken to be zero. The system of equations to calculate these quantities was originally derived. The Neutron Multiplicity 3 He Array Detector (NOMAD) consists of 15 3 He tubes inside polyethylene and is the traditional, capture-based detection system for NMC. The polyethylene moderates incoming neutrons for thermal capture in individual tubes. The low gamma background, discrete capture signals, and high efficiency of the NOMAD are beneficial for NMC. However, the time to slow down neutrons to thermal energies leads to a system die away time on the scale of microseconds. Comparatively, the Rossi-alpha Measurements – Rapid Organic (n, γ) Discrimination Detector (RAMRODD) and the Organic Scintillator Array (OSCAR) are scatter-based detection systems. RAMRODD consists of 8, 5.08 by 5.08 cm EJ-309 liquid scintillators in 4 pairs, evenly-spaced with 90 degrees separation about the center of each assembly. OSCAR consists of a single array of 12, 5.08 by 5.08 cm trans-stilbene crystals aligned with the center of the assembly. Scatter-based systems detect fast neutrons without any moderation, leading to system die away times on the scale of tens of nanoseconds. This allows much shorter timing gate widths compared to thermal systems, thus increasing counting statistics of true correlated fission events. However, scatter-based systems are susceptible to neutron cross-talk when an incident neutron scatters off one detector and interacts in an adjacent detector, causing two seemingly correlated detection signals. The equations developed adjust for cross-talk to conduct NMC with scatter-based systems.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Sensitivity-based Experiment Design Optimization for a Molybdenum Critical Experiment

A lack of intermediate molybdenum benchmarks in the ICSBEP has been identified by LANL, Y-12, and IRSN. This lacking adversely effects criticality safety operations and leaves new differential molybdenum data unvalidated. NCERC is proposing a series of intermediate integral experiments to better the understanding of molybdenum systems. Using MCNP6.2 with the ENDF/B-VIII.0 nuclear data library a single unmoderated and four moderated system designs were identified using a sensitivity optimization method. Each proposed system was found to be at least twice as sensitive to the 95 Mo capture cross section in the URR as the sole existing intermediate molybdenum benchmark in the ISCBEP handbook. The addition of a new molybdenum sensitive intermediate system would improve future nuclear data evaluations.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Validation of Jezebel Reactivity Coefficients and Sensitivity Analysis

Nuclear data validation is often performed today using criticality measurements. The gold standard for criticality measurements is the International Criticality Safety Benchmark Experiment Project (ICSBEP). The validation specifically focuses on the effective multiplication factor ($k_{eff}$). $K_{eff}$ is a relatively easy parameter to infer and has reduced uncertainty due to being at or above critical. However, while $k_{eff}$ is the most documented parameter and its uncertainties and sensitivities have been evaluated in great detail, it cannot be used as a standalone metric to determine inaccuracies in nuclear data (e.g., cross section data, PFNS, nu), which is based on theory, physics, and differential measurements. The Experiments Underpinned by Computational Learning for Improvements in nuclear Data (EUCLID) project aims to identify compensating errors in specific isotope nuclear data by optimally designing experiments that are, or are not sensitive to a suite of measurement parameters beyond $k_{eff}$. By identifying parameters that are sensitive to each other, oppositely sensitive, or have substantial magnitude differences in sensitivity, experiments can be designed to constrain questionable nuclear data. One sensitivity that is of particular interest to this project includes the sensitivity of reactivity coefficients. Reactivity coefficients compare reactivity, which is related to $k_{eff}$ at two different states therefore being sensitive to small changes in the system. The most common type of reactivity coefficient measurements is comparison to void for a small sample within the assembly. It is key that the sample sizes are small enough to not affect the flux of the full system. Reactivity coefficients were evaluated for many early experiments to better understand transport corrected cross sections. In fact, ICSBEP includes reactivity coefficient results as “Supplemental Measurements” in appendices for a handful of older benchmarks. One of those benchmarks is Jezebel, the bare Pu critical assembly. This paper compares new simulations of reactivity coefficients for Jezebel, and explores the sensitivity of reactivity coefficients to small changes in nuclear data.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

A Verification of Flux Sensitivity Estimates Using the MCNP Tally Perturbation Tool

Nuclear data is commonly used in applications such as nuclear nonproliferation, safeguards, and criticality safety. More specifically, nuclear data is used in predictive simulation codes like the Monte-Carlo N-Particle (MCNP ® ) transport code, Serpent, and similar radiation transport codes. The improvement of nuclear data enables more precise and accurate simulations, which result in higher fidelity designs and reduced operational/procedural costs. Therefore, the improvement of nuclear data is of paramount importance across the nuclear community. Nuclear data is improved and validated through integral benchmark experiments. The design of benchmark experiments is an extensive process; therefore, these experiments are often optimized on multiple characteristics, including sensitivity to the nuclear data, during the design process. Sensitivity is a measure of how much a quantity changes due to changes in independent variables such as experimental configuration. An experimental design that has a larger sensitivity to the nuclear data of interest will have a larger impact on the accuracy and precision of the validated data. Past integral benchmark experiments have primarily used the effective multiplication factor ($k_{eff}$) as the predominant measured quantity; however, experiments designed with other quantities in mind would be able to optimize on validating different areas of the nuclear data. A primary goal of the EUCLID project is to design, constrain, and reduce compensating errors in experiments focused on quantities other than $k_{eff}$ to better validate nuclear data across the board. Currently, there is a capability in MCNP to easily calculate the sensitivity of $k_{eff}$ to specific nuclear data of numerous reactions types and isotopes (KSEN card); however, the sensitivity of other quantities must be estimated in more strenuous manners. For example, the perturbation feature (PERT card) of MCNP can be used to estimate first-order sensitivities of some response in fixed source simulations. A recent announcement revealed that the first- and second-order perturbation features in previous releases of MCNP contained a bug. It was identified that particles were being scored into the wrong energy bin. The bug is in the most recent public release (MCNP6.2); however, a patch has been added to the most up to date version (MCNP6.2.2) that has not been released publicly. A direct comparison of the PERT card results for an F4 (neutron flux averaged over a cell) tally before and after the patch are shown in figure 1. All simulations used in the sensitivity estimates in this report were performed with MCNP6.2.2. This work verifies the patched MCNP perturbation tool by comparing first order sensitivities made using the PERT card to estimates made using manual perturbation of the compact ENDF (ACE) files.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Sensitivity-based Similarity Metrics for New Experiment Design Optimization

The nuclear data used in advanced reactor simulations requires validation. Data from nuclear criticality experiments can provide this validation. New nuclear criticality experiment design requires extensive knowledge and expert judgement such that the experimental design parameters are selected in such a way to keep the experiment subcritical. To aide in this experimental design process, professionals can utilize sensitivity and uncertainty analysis. Sensitivity and uncertainty analysis relies on matching new application experiments with currently existing benchmark experiments. Currently, there is functionality in the Whisper 1.1 software package to calculate a similarity metric based on neutron multiplication factor sensitivity coefficients between a new application designed by the user and existing International Criticality Safety Benchmark Experiment Project (ICSBEP) benchmarks. The Whisper 1.1 software package is included in Monte Carlo N-Particle ® Code Version 6.21 (MCNP ® 6.2). This work is geared toward expanding this capability to new similarity metrics based on beta-effective sensitivity coefficients and reactivity coefficient sensitivity coefficients. While the investigation of these sensitivity coefficients is presented in detail in separate works at this same conference, this work will be primarily focused on studying the similarity metrics in more detail. These similarity metrics will then be incorporated into the optimization algorithms used for experiment design in EUCLID (Experiments Underpinned by Computational Learning for Improvements in nuclear Data), which is a Los Alamos National Laboratory (LANL) project designed to constrain nuclear data of interest, such that adjustments can be made to possible inaccuracies. A more detailed optimization can be subsequently performed by breaking down these similarity metrics by isotope, reaction, and energy.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

FLASSH 1.0: Full Law Analysis Scattering System Hub

Nuclear technologies, such as thermal reactors and critical systems, are driven by reaction rates which are directly dependent on thermal neutrons. The ability to calculate reaction rates is directly linked to the capability to predict and understand the cross sections. For atoms bound within a material structure, the available modes of energy exchange are captured in the Thermal Scattering Law (TSL, i.e. S(α,β)). The TSL is fundamentally a material property and can be defined explicitly to account for the excitation and deexcitation of the lattice energy states. This work describes the development of the Full Law Analysis Scattering System Hub (FLASSH) which calculates the TSL and cross sections. FLASSH is a modern code which has been designed to produce accurate TSL evaluations, remove historical approximations, and improve formulations while making advance physics accessible and simple to use.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Validation of KENO Delayed Neutron Fraction Capabilities

The delayed neutron fraction, which is necessary for the safe operation of reactors, varies by fissionable material and neutron spectrum. A prompt fission neutron spectrum has been included in the SCALE 6.2 release to account for the removal of delayed neutrons from precursor materials from the neutron balance. This paper describes how experimental measurements from criticality safety benchmarks were used to validate the SCALE calculational procedure for the delayed neutron fraction. Additionally, the effect of nuclear data uncertainty on the KENO calculation of β eff was examined with the SAMPLER sequence.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Performance of the Initial Implementation of the Shift Monte Carlo Code in SCALE 6.3

The Shift Monte Carlo code will be introduced in SCALE 6.3 as an alternative to the KENO V.a, KENO-VI, and Monaco codes. Calculations were performed to establish the performance of Shift for criticality safety analyses within the criticality safety analyses sequence (CSAS) based on models in the Verified, Archived Library of Inputs and Data (VALID). This test suite contains over 600 critical experiment models covering a broad range of fissile materials and neutron energy spectra. The comparisons presented include calculated k eff values and runtime performance for serial calculations and a selection of parallel calculations. Comparisons are presented for multigroup (MG) and continuous-energy (CE) calculations for KENO V.a and KENO-VI models. Results generated with a beta version of SCALE 6.3 indicate excellent agreement in k eff values between KENO and Shift. The largest differences in the average k eff value calculated for the 15 categories of KENO V.a models are 0.00020 ± 0.00011 Δ k for MG calculations and 0.00011 ± 0.00005 Δ k for CE calculations. Similar comparisons in three categories using KENO-VI result in the largest differences for MG calculations: as 0.00004 ± 0.00003 Δ k , and -0.00002 ± 0.00003 Δ k for CE. The preliminary results also indicate that Shift is faster than KENO on a per particle basis, especially for fast spectrum systems. The uncertainty per history is also higher, however, so the Monte Carlo figure of merit is higher for KENO for thermal and intermediate spectrum systems. As expected, Shift generally has better speedup than KENO for parallel calculations, regardless of neutron energy spectrum.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Update of the Nuclear Criticality Slide Rule Calculations: Plutonium systems – Delayed Fission Gamma

IRSN (France), LLNL (USA) and ORNL (USA) began a long-term collaboration effort in 2015 to update the nuclear criticality Slide Rule for the emergency response to a nuclear criticality accident. The Slide Rule permits the estimation of neutron and gamma dose rates and integrated doses based upon estimated fission yields, as a function of distance from the fission source, and time after criticality accidents for different critical systems. This paper presents results from the fourth phase of the current update of the Slide Rule project, in which delayed fission-product gamma (DFG) dose rates of unreflected plutonium critical systems were compared by several modern 3D radiation transport codes (MCNP, COG, SCALE), using updated flux-to-dose conversion factors. Dose rates are calculated for fissile material at five moderation ratios (H/Pu), at 1 m above the ground as a function of distance (between 30 cm and 1,200 m) from the external surface of the source to the center of the detector, and for periods between 1 s and 1,000 min after the critical instantaneous event. Further efforts have been devoted to the determination of the delayed gamma source, by comparing the time-dependent energy spectra obtained from several methods. Overall, DFG dose rates calculated by each participant led to consistent results. Extra effort is under way to identify the cause of the remaining differences, by comparing precisely the gamma source, and particularly nuclides inventories.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗