Development of a Low Toxicity Urine Pretreatment for Water Recovery in Space

Wastewater stabilization was an essential component of the spacecraft water cycle. The purpose of stabilizing wastewater was two-fold. First, stabilization prevents the breakdown of urea into ammonia, a toxic gas at high concentrations. Second, it prevents the growth of microorganisms, thereby mitigating hardware and water quality issues due to due biofilm and planktonic growth. Current stabilization techniques involve oxidizers and strong acids (pH=2) such as chromic and sulfuric acid, which are highly toxic and pose a risk to crew health. The purpose of this effort was to explore less toxic stabilization techniques, such as food-grade and commercial care preservatives. Additionally, certain preservatives were tested in the presence of a low-toxicity organic acid. Triplicate 300-mL volumes of urine were dosed with a predetermined quantity of stabilizer and stored for two weeks. During that time, pH, total organic carbon (TOC), ammonia, and turbidity were monitored. Those preservatives that showed the lowest visible microbial growth and stable pH were further tested in a six-month stability study. The results of the six-month study are also included in this paper. Additionally, the pretreatment formulations were tested to determine if the pretreated urine could be distilled to remove 85% of the water, as would occur on the ISS. The goal of the pretreatment was to produce no solids in the resulting brine at 85% water recovery.

Adam, Niklas↗

Development of Low-Toxicity Wastewater Stabilization for Spacecraft Water Recovery Systems

Wastewater stabilization was an essential component of the spacecraft water cycle. The purpose of stabilizing wastewater was two-fold. First, stabilization prevents the breakdown of urea into ammonia, a toxic gas at high concentrations. Second, it prevents the growth of microorganisms, thereby mitigating hardware and water quality issues due to due biofilm and planktonic growth. Current stabilization techniques involve oxidizers and strong acids (pH=2) such as chromic and sulfuric acid, which are highly toxic and pose a risk to crew health. The purpose of this effort was to explore less toxic stabilization techniques, such as food-grade and commercial care preservatives. Additionally, certain preservatives were tested in the presence of a low-toxicity organic acid. Triplicate 300-milliliter volumes of urine were dosed with a predetermined quantity of stabilizer and stored for two weeks. During that time, pH, total organic carbon (TOC), ammonia, and turbidity were monitored. Those preservatives that showed the lowest visible microbial growth and stable pH were further tested in a six-month stability study. The results of the six-month study are also included in this paper.

Mitchell, Julie L.↗

Proton-Radiation Tolerant All-Perovskite Multijunction Solar Cells

Radiation-resistant but cost-efficient, flexible, and ultralight solar sheets with high specific power (W g -1 ) are the "holy grail" of the new space revolution, powering private space exploration, low-cost missions, and future habitats on Moon and Mars. Herein, this study investigates an all-perovskite tandem photovoltaic (PV) technology that uses an ultrathin active layer (1.56 micrometers) but offers high power conversion efficiency, and discusses its potential for high-specific-power applications. This study demonstrates that all-perovskite tandems possess a high tolerance to the harsh radiation environment in space. The tests under 68 MeV proton irradiation show negligible degradation (<6%) at a dose of 10 13 p + cm -2 where even commercially available radiation-hardened space PV degrade >22%. Using high spatial resolution photoluminescence (PL) microscopy, it is revealed that defect clusters in GaAs are responsible for the degradation of current space-PV. By contrast, negligible reduction in PL of the individual perovskite subcells even after the highest dose studied is observed. Studying the intensity-dependent PL of bare low-gap and high-gap perovskite absorbers, it is shown that the V OC , fill factor, and efficiency potentials remain identically high after irradiation. Radiation damage of all-perovskite tandems thus has a fundamentally different origin to traditional space PV.

14 SOLAR ENERGY↗

Depth distribution of absorbed dose on the external surface of Cosmos 1887 biosatellite

Significant absorbed dose levels exceeding 1.0 Gy day(exp -1) have been measured on the external surface of the Cosmos 1887 biosatellite as functions of depth in stacks of thin thermoluminescent detectors (TLD's) made in U.S.S.R. and U.S.A. The dose was found to decrease rapidly with increasing absorber thickness, thereby indicating the presence of intensive fluxes of low-energy particles. Comparison between the U.S.S.R. and U.S.A. results and calculations based on the Vette Model environment are in satisfactory agreement. The major contribution to the dose under thin shielding thickness is shown to be from electrons. The fraction of the dose due to protons and heavier charged particles increases with shielding thickness.

Watts, J. W., Jr.↗

Depth distribution of absorbed dose on the external surface of Cosmos 1887 biosatellite

Significant absorbed dose levels exceeding 1.0 Gy day-1 have been measured on the external surface of the Cosmos 1887 biosatellite as functions of depth in stacks of thin thermoluminescent detectors (TLDs) of U.S.S.R. and U.S.A. manufacture. The dose was found to decrease rapidly with increasing absorber thickness, thereby indicating the presence of intensive fluxes of low-energy particles. Comparison between the U.S.S.R. and U.S.A. results and calculations based on the Vette Model environment are in satisfactory agreement. The major contribution to the dose under thin shielding thickness is shown to be from electrons. The fraction of the dose due to protons and heavier charged particles increases with shielding thickness.

NASA Discipline Number 04-10↗

Estimating the Noise Floor of Sonic Boom Metrics Across the USA

NASA is building the X-59 Quiet Supersonic Technology aircraft to produce low noise sonic booms for a series of community noise surveys across the USA. Survey participants will rate their perception of the low booms from supersonic X-59 flyovers. Several noise metrics are proposed to quantify the noise dose: A-, B-, D-, E-weighted Sound Exposure Level, Stevens Perceived Level, and Indoor Sonic Boom Annoyance Predictor. Sparse measurements across the survey area will be used to estimate community noise exposure. The level of these low booms may be comparable to the ambient noise level in some locations, leading to uncertainty in noise exposure estimations. This uncertainty may necessitate increased reliance on sonic boom propagation predictions for exposure estimation. Low-boom signal to ambient noise ratio is one way to quantify uncertainty in measured sonic boom levels. An empirical relationship between A-weighted ambient level and sonic boom metric levels is used in conjunction with the National Park Service’s L50 SPL map to estimate sonic boom metric ambient levels across the USA. The estimate of ambient sonic boom metric levels will aid in X-59 test planning and execution.

sonic boom↗

Measured vs. Calculated Dose Rates During Ring Injection Dump Replacement

One of the most irradiated Spallation Neutron Source (SNS) accelerator components is the ring injection dump (RID), which is located downstream of the accumulator ring injection section. The unstripped and only partially stripped H - beam, about 5% of the full SNS beam current, is discarded in the injection into the accumulator ring and is redirected to the RID. According to the accelerator operation plan, the beam stop and the window assemblies of the existing RID are removed and replaced when they have reached their end-of-life owing to radiation exposure. This procedure, which includes multiple steps, took place during a facility maintenance period in March 2023. To support work planning and meet as low as reasonably achievable (ALARA) requirements during removal and exchange of the components, dose rates were calculated for each stage of the exchange operation. During each stage, dose rates were measured before and after work. This comparison shows that measured dose rates are within a factor of 2 of the predicted (calculated) dose rates.

43 PARTICLE ACCELERATORS↗

Estimated Ambient Sonic Boom Metric Levels and X-59 Signal-to-Noise Ratios across the USA

NASA is building the X-59 Quiet Supersonic Technology aircraft to produce low noise sonic booms for a series of community noise surveys across the USA. Survey participants will rate their perception of the low-booms from supersonic X-59 flyovers. Several noise metrics are proposed to quantify the noise dose: A-, B-, D-, and E-weighted Sound Exposure Level, Stevens Perceived Level, and Indoor Sonic Boom Annoyance Predictor. Sparse measurements across the survey area will be used to estimate community noise exposure. The level of these low-booms may be comparable to the ambient noise level in some locations, leading to uncertainty in noise exposure estimations. This uncertainty may necessitate increased reliance on sonic boom propagation predictions for exposure estimation. Low-boom signal to ambient noise ratio is one way to quantify uncertainty in measured sonic boom levels. An empirical relationship between A-weighted ambient level and sonic boom metric levels is used in conjunction with the National Park Service’s L50 SPL map to estimate ambient noise levels expressed in terms of sonic boom noise metrics across the USA. These estimates of ambient levels will aid in X-59 community test planning and execution. The signal-to-noise ratio for the undertrack X-59 sonic boom is also estimated, and an example application of these data is presented for comparing potential noise monitor sites prior to a community noise test.

X-59↗

System Model Calculations for the Active Trenches of the Low-Level Burial Grounds, Hanford Site, Washington

Two lined trenches (Trench 31 and 34) located within the 200 West Low-Level Burial Ground (LLBG) area of the U.S. Department of Energy’s (DOE) Hanford Site are designated for permanent disposal of low-level radioactive waste (LLW) and mixed low-level radioactive waste (MLLW). In accordance with DOE O 435.1, Radioactive Waste Management, radioactive waste shall be managed and disposed in a manner that is protective of worker, public health and safety, and the environment. DOE O 435.1 requires a site-specific radiological performance assessment (PA) that includes calculations of potential releases and subsequent doses to members of the public for a period of 1,000 years after closure of a low-level waste (LLW) disposal facility. The purpose of this environmental calculation file (ECF) is to document the various dose calculations performed to support DOE’s LLBG PA. The dose assessments are performed to evaluate the potential exposure of an all-pathway representative person to radionuclide contaminants of potential concern (COPCs) that may be released from the LLBG Trenches 31 and 34 to the point of calculation (POC) located at the outer edge of a 100 m buffer zone surrounding the trench boundary. This ECF uses inputs from other ECFs and their associated model package reports (MPRs) supporting the LLBG PA. The five major objectives of this ECF are to present the results of the following: (1) Deterministic dose assessments for both groundwater and atmospheric exposure scenarios; (2) Radon-222 (Rn-222) flux emanating at the surface from the disposed wastes; (3) Uncertainty analyses of the groundwater pathway annual dose due to uncertainty in input parameters; (4) Sensitivity analyses of the input parameters that could potentially impact the fate and transport of the contaminants and doses; (5) Doses arising from inadvertent intruder exposure scenarios.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Dose-Response Data Considerations for the NASA Quesst Community Test Campaign

Key outcomes for NASA's Quesst mission are noise dose and perceptual response data to inform regulators on their decisions regarding noise certification standards for the future of overland commercial supersonic flight. Dose-response curves are commonly utilized in community noise studies to describe the annoyance of a community to a particular noise source. The X-59 aircraft utilizes shaped-boom technology to demonstrate low noise supersonic flight. For X-59 community studies, the sound level from X-59 overflights constitutes the dose, while the response is an annoyance rating selected from a verbal scale, e.g., “slightly annoyed” and “very annoyed.” Dose-response data will be collected from individual flyovers (single event dose) and an overall response to the accumulation of single events at the end of the day (cumulative dose). There are quantifiable sources of error in the noise dose due to uncertainty in microphone measurements of the sonic thumps and uncertainty in predicted noise levels at survey participant locations. Assessing and accounting for error in the noise dose is essential to obtain an accurate dose-response model. There is also a potential for error in the perceptual response. This error is due to the ability of participants to provide their response in a timely manner and participant fatigue after responding to up to one hundred surveys over the course of a month. This talk outlines various challenges in estimating noise dose and perceptual response and the methods considered in preparation for X-59 community tests.

dose-response↗

Response of a tissue equivalent proportional counter to neutrons

The absorbed dose as a function of lineal energy was measured at the CERN-EC Reference-field Facility (CERF) using a 512-channel tissue equivalent proportional counter (TEPC), and neutron dose equivalent response evaluated. Although there are some differences, the measured dose equivalent is in agreement with that measured by the 16-channel HANDI tissue equivalent counter. Comparison of TEPC measurements with those made by a silicon solid-state detector for low linear energy transfer particles produced by the same beam, is presented. The measurements show that about 4% of dose equivalent is delivered by particles heavier than protons generated in the conducting tissue equivalent plastic. c2002 Elsevier Science Ltd. All rights reserved.

NASA Center JSC↗

The Steel Equivalency Workbook: An X-Ray Transmission Calculator

The Steel Equivalency Spreadsheet was created as a robust, user-friendly method for the following: 1. Determining if it is possible to image an object. 2. Reducing time needed when selecting equipment and preparing for field imaging activities. 3. Reducing the amount of equipment taken for field imaging activities. 4. Determining a starting point for exposure settings prior to imaging an object. 5. Reducing the amount of dose deposited to complete an imaging operation (in the spirit of As Low As Reasonably Achievable, ALARA). The spreadsheet was developed using various physical models to account for different phenomena. Future implementations aim to expand beyond the Digital Radiography and Computed Tomography Single Munition Scanner (DRCT SMS) in standard configuration to include high energy XRGs (Betatrons) and sub-MeV pulsed XRGs (XRS4). Alternative computational methods that compensate for incoherent scattering when calculating relative transmission are also being pursued. Ultimately the spreadsheet exceeded the developmental goal of having less than 10% average error when comparing calculations to real-world images.

36 MATERIALS SCIENCE↗

Evaluation of Minimum Detectable Activities for Stack Sample Analyses

The Rad-NESHAP program takes samples at major point sources to track how much of select nuclides are being emitted out of the stack. Samples are taken at the site where the radiological operations are being performed. The samples are then sent to analytical laboratories for analysis to determine what nuclides exist in the sample. However, due to the sensitivity of the instruments, false positives are often reported. To reduce the number of false positives, the results reported from the analytical labs are compared to set detection limits. Anything below the set detection limit is considered part of the background while anything above the limit is considered a positive hit. Therefore, the detection limit must be set low enough that any false negatives do not result in a significant dose missed at the end of the year but high enough that there are not enough false positives to skew the annual dose being reported. All detection limits listed in this section for the analyses below were designed to meet the stated equivalent emissions rate and subsequent off-site doses. These minimum detectable activities (MDAs) were developed in the 1990s and documented in the memo cited for each analysis below. These limits and memos are all currently referenced in the Quality Assurance Project Plan (QAPP) for the Rad-NESHAP Compliance Task, which is being updated to a Project Implementation Plan (PIP) concurrently with this document. As part of this update process, the original MDAs defined in this section needed to be verified that they were still conservative and meet the off-site dose levels stated.

2019 MDA↗

Prostacyclin-induced hyperthermia - Implication of a protein mediator

The mechanism of the prostacyclin-linked hyperthermia is studied in rabbits. Results show that intracerebroventricular administration of prostacyclin (PGI2) induces dose-related hyperthermia at room temperature (21 C), as well as at low (4 C) and high (30 C) ambient temperatures. It is found that this PGI2-induced hyperthermia is not mediated by its stable metabolite 6-keto prostaglandin F-1(alpha). Only one of the three anion transport systems, the liver transport system, appears to be important to the central inactivation of pyrogen, prostaglandin E2, and PGI2. Phenoxybenzamine and pimozide have no thermolytic effect on PGI2-induced hyperthermia, while PGI2 still induces hyperthermia after norepinephrine (NE) and dopamine levels are depleted by 6-hydroxydopamine. Indomethacin and SC-19220 (a PG antagonist) do not antagonize PGI2 induced hyperthermia, while theophylline does not accentuate the PGI2-induced hyperthermia. However, the hyperthermic response to PGI2 is attenuated by central administration of the protein synthesis inhibitor, anisomycin. It is concluded that PGI2-induced hyperthermia is not induced by NE, dopamine, or cyclic AMP, but rather that a protein mediator is implicated in the induction of fever by PG12.

Kandasamy, S. B.↗

Optical fibers and components experiment (A0138-7)

Fiber optics permanent damages induced by ionizing radiation after a long exposure in space and after laboratory tests were examined. Irradiation tests performed with radioactive sources (Sr90 - Y90) were validataed, computer coses used for the fluence and dose profile were verified. The performance of fiber optics waveguides in a low altitude orbit, and the origin of transmission losses in the material were dtermined. High sensitivity to ionizing radiations, however, may be a restriction for optic fiber use on satellites. Irradiation tests on these components using neutrons, gamma rays, and X-rays are carried out. Radiation damage on opticao materials, however, is strongly linked to the test conditions.

Bourrieau, J.↗

Xylazine emesis, yohimbine and motion sickness susceptibility in the cat

The possible role of the alpha-2 adrenoceptors in xylazine-induced vomiting and in motion sickness was investigated. Cats were divided into two groups according to motion sickness susceptibility and were observed after s.c. injections of xylazine. The incidence of vomiting increased with the dose, and at each dose the high susceptibility group had a greater emetic incidence than the low susceptibility group. In another experiment with cats divided into two groups according to motion sickness susceptibility, s.c. administration of yohimbine effectively antagonized the xylazine-induced emesis in both susceptibility groups. The cats in the latter experiment were then challenged with a motion sickness stimulus after s.c. pretreatment with yohimbine. Yohimbine failed to prevent motion sickness but did occasion an unexplained variability in the incidence of vomiting. These findings suggest that the emetic effect of xylazine results from stimulation of alpha-2 adrenoceptors but that these receptors are not fundamental to feline motion sickness. The fact that susceptibilities to xylazine-induced emesis and to motion sickness are correlated suggests a point of interaction other than the area postrema, which is known to be essential for xylazine-induced vomiting but not for motion sickness in the cat.

Lucot, James B.↗

Novel Material for Future Spacecrafts

Outside earth's protective magnetosphere crew members and sensitive equipment need to be protected against two primary radiation sources, namely Galactic Cosmic Rays (GCR) and Solar Energetic Particles (SEP). For planetary missions, this combination of radiation particles could result in doses that are higher than the allowable level currently permitted for low-earth orbit manned missions. This SBIR project aims to develop a multifunctional and lightweight composite material that not only provides sufficient radiation shielding but also provides sufficient structural integrity to be considered as a spacecraft material. This presentation will discuss the deep space radiation problem and the material based solutions being proposed by BAE SYS scientists to overcome this problem. The presentation will focus on the initiative taken by BAE SYS scientists to proactively engage and team with experts at NASA, small business, and other federal laboratories to develop and test a dual phase composite material. The presentation will also highlight the potential benefits to our customer, NASA and also to BAE SYS.

Sen, Subbayu↗