Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “local grid”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 847 records · Page 47

Exploring Hypersonic, Unstructured-Grid Issues through Structured Grids

Pure-tetrahedral unstructured grids have been shown to produce asymmetric heat transfer rates for symmetric problems. Meanwhile, two-dimensional structured grids produce symmetric solutions and as documented here, introducing a spanwise degree of freedom to these structured grids also yields symmetric solutions. The effects of grid skewness and other perturbations of structured-grids are investigated to uncover possible mechanisms behind the unstructured-grid solution asymmetries. By using controlled experiments around a known, good solution, the effects of particular grid pathologies are uncovered. These structured-grid experiments reveal that similar solution degradation occurs as for unstructured grids, especially for heat transfer rates. Non-smooth grids within the boundary layer is also shown to produce large local errors in heat flux but do not affect surface pressures.

Mazaheri, Ali R.↗

A Satellite-Derived Climate-Quality Data Record of the Clear-Sky Surface Temperature of the Greenland Ice Sheet

We have developed a climate-quality data record of the clear-sky surface temperature of the Greenland Ice Sheet using the Moderate-Resolution Imaging Spectroradiometer (MODIS) Terra ice-surface temperature (1ST) algorithm. A climate-data record (CDR) is a time series of measurements of sufficient length, consistency, and continuity to determine climate variability and change. We present daily and monthly Terra MODIS ISTs of the Greenland Ice Sheet beginning on 1 March 2000 and continuing through 31 December 2010 at 6.25-km spatial resolution on a polar stereographic grid within +/-3 hours of 17:00Z or 2:00 PM Local Solar Time. Preliminary validation of the ISTs at Summit Camp, Greenland, during the 2008-09 winter, shows that there is a cold bias using the MODIS IST which underestimates the measured surface temperature by approximately 3 C when temperatures range from approximately -50 C to approximately -35 C. The ultimate goal is to develop a CDR that starts in 1981 with the Advanced Very High Resolution (AVHRR) Polar Pathfinder (APP) dataset and continues with MODIS data from 2000 to the present. Differences in the APP and MODIS cloud masks have so far precluded the current IST records from spanning both the APP and MODIS IST time series in a seamless manner though this will be revisited when the APP dataset has been reprocessed. The Greenland IST climate-quality data record is suitable for continuation using future Visible Infrared Imager Radiometer Suite (VIIRS) data and will be elevated in status to a CDR when at least 9 more years of climate-quality data become available either from MODIS Terra or Aqua, or from the VIIRS. The complete MODIS IST data record will be available online in the summer of 2011.

Hall, Dorothy K.↗

Transaction-Based Controls for Building-Grid Integration: VOLTTRON™

The U.S. Department of Energy’s (DOE’s) Building Technologies Office (BTO) is supporting the development of a “transactional network” concept that supports energy, operational, and financial transactions between building systems (e.g., rooftop units -- RTUs), and the electric power grid using applications, or 'agents', that reside either on the equipment, on local building controllers, or in the Cloud. The transactional network vision is delivered using a real-time, scalable reference platform called VOLTTRON that supports the needs of the changing energy system. VOLTTRON is an agent execution and an innovative distributed control and sensing software platform that supports modern control strategies, including agent-based and transaction-based controls. It enables mobile and stationary software agents to perform information gathering, processing, and control actions.

DOE↗

Multigrid method for stability problems

The problem of calculating the stability of steady state solutions of differential equations is addressed. Leading eigenvalues of large matrices that arise from discretization are calculated, and an efficient multigrid method for solving these problems is presented. The resulting grid functions are used as initial approximations for appropriate eigenvalue problems. The method employs local relaxation on all levels together with a global change on the coarsest level only, which is designed to separate the different eigenfunctions as well as to update their corresponding eigenvalues. Coarsening is done using the FAS formulation in a nonstandard way in which the right-hand side of the coarse grid equations involves unknown parameters to be solved on the coarse grid. This leads to a new multigrid method for calculating the eigenvalues of symmetric problems. Numerical experiments with a model problem are presented which demonstrate the effectiveness of the method.

Ta'asan, Shlomo↗

An Adaptive Approach to Energy Security and Assurance

The North American power network has been called the world s largest, most complex machine. This network represents an enormous continent-wide investment, including over 15,000 generators in 10,000 power plants, and miles of transmission lines, distribution networks, and control systems. It has long been recognized that existing power-delivery systems are vulnerable to natural disasters and adversarial attack. The next generation of control systems must simultaneously protect against these disruptions while integrating new generation sources and maintaining active, automated control of the grid. The grid s interconnectedness needed to provide smart grid control also increases its vulnerability to interconnect-wide disruptions that are initiated locally. While strong centralized control is essential to reliable operations, this control requires multiple, high-data-rate, two-way communication links, a powerful central computing facility, and an elaborate operation-control center, all of which present vulnerabilities. It is clearly impossible to completely protect such a widespread and complex system. The key to maintaining the integrity of this network lies in the ability to identify its critical elements and to then effectively protect these elements. This identification and targeted protection will enable parts of the network to remain operational and even automatically reconfigure in the event of local failures or threats of failure, providing dependable continuity of service. The bold concept proposed here is the communication, predictive models and fast controls that eliminate the need to protect all components from emergent contingencies, but to reconfigure actively to maintain critical functions. The transformation from laboratory applications to larger than micro grid areas will require the next generation of energy technologies.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Sensitivity of passive microwave sea ice concentration algorithms to the selection of locally and seasonally adjusted tie points

The sensitivity of passive microwave sea-ice concentration (SIC) algorithms to the selection of tie points was analyzed. SICs were derived with the NASA Team ice algorithm for global tie points and for locally and seasonally adjusted tie points. The SSM/I SIC was then compared to Landsat-MSS-derived SICs. Preliminary results show a mean difference of SSM/I- and Landsat-derived SICs for 50 x 50 km grid cells of 2.7 percent along the ice edge of the Beaufort Sea during fall with local tie points. The accuracy decreased to 9.7 percent when global tie points were used. During freeze-up in the Beaufort Sea, with grey ice and nilas as dominant ice cover, the mean difference was 4.3 percent for local tie points and 13.9 percent for global tie points. For the spring ice cover in the Bering Sea a mean difference of 4.4 percent for local tie points and 15.7 percent for global tie points was found. This large difference reveals some limitations of the NASA-Team algorithm under freeze-up and spring conditions (thin ice areas).

Steffen, Konrad↗

An Extended Lagrangian Method

A unique formulation of describing fluid motion is presented. The method, referred to as 'extended Lagrangian method,' is interesting from both theoretical and numerical points of view. The formulation offers accuracy in numerical solution by avoiding numerical diffusion resulting from mixing of fluxes in the Eulerian description. The present method and the Arbitrary Lagrangian-Eulerian (ALE) method have a similarity in spirit-eliminating the cross-streamline numerical diffusion. For this purpose, we suggest a simple grid constraint condition and utilize an accurate discretization procedure. This grid constraint is only applied to the transverse cell face parallel to the local stream velocity, and hence our method for the steady state problems naturally reduces to the streamline-curvature method, without explicitly solving the steady stream-coordinate equations formulated a priori. Unlike the Lagrangian method proposed by Loh and Hui which is valid only for steady supersonic flows, the present method is general and capable of treating subsonic flows and supersonic flows as well as unsteady flows, simply by invoking in the same code an appropriate grid constraint suggested in this paper. The approach is found to be robust and stable. It automatically adapts to flow features without resorting to clustering, thereby maintaining rather uniform grid spacing throughout and large time step. Moreover, the method is shown to resolve multi-dimensional discontinuities with a high level of accuracy, similar to that found in one-dimensional problems.

Liou, Meng-Sing↗

CFD-Informed Spacer Grid Models in the Subchannel Code CTF

Data from computational fluid dynamics (CFD) simulations can be utilized to improve the predictive capabilities of the subchannel code CTF. Past work incorporating CFD results into CTF has included accounting for directed crossflow and turbulent mixing between adjacent subchannels. Spacer grids impact fluid flow in various ways, and this work focuses on four spacer grid effects, namely: 1. Directed crossflow; 2. Turbulent mixing; 3. Enhanced downstream heat transfer; 4. Pressure drop correlation. Heat transfer augmentation occurs partially due to the disturbances in the developed flow and from the additional turbulence generated by the presence of obstructions in the fluid flow's path. The boundary layer disruption is caused in part by the newly-directed flow just downstream of the spacer grid vanes. This effect lessens as the distance from the grid increases and the flow returns to its developed state, closer to what would be expected in a bare subchannel. Current plans of this work are to develop a method for incorporating the effects of spacer grids on the heat transfer calculation within CTF. Proposed techniques include the addition of an enhancement factor to the local heat transfer coefficient. The inclusion of CFD data from properly-designed simulations will allow CTF to better predict parameters such as fluid temperatures near spacer grids. Improved pressure loss coefficients for each grid can also be generated using CFD simulations. The heat transfer modification has been studied, with other authors noting correlations which are dependent on grid properties such as the blockage ratio. Parameters considered in this study are the turbulent kinetic energy (TKE) and vorticity. There are currently no models to calculate or store either of these parameters within CTF. When accounting for spacer grid effects in CTF, it is important to not double-count the effects towards two different CTF models. This requires carefully designing CFD simulations around capturing specific phenomena from the grids and being able to apply these CFD results to all appropriate flow conditions. (authors)

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Self-Protective Inverters Against Malicious Setpoints Using Analytical Reference Models

This paper presents the concept of self-protective inverters using reference models. In the proposed method, incoming setpoints from the utility operator or third-party aggregators are inspected using analytical reference models before engaging the setpoints to the inverter’s local controller. When a malicious setpoint passes the existing security layers, a smart inverter can examine the integrity of an incoming setpoint in real-time. The efficacy of the developed method has been tested using a laboratory setup, including a three-phase 3kVA SiC-MOSFET inverter and a 12kW NHR 9410 regenerative grid emulator. Furthermore, the results verify that the developed analytical models can provide device-level protection for grid-interactive inverters by inspecting and preventing harmful setpoints from getting engaged to the local controller.

42 ENGINEERING↗

Distributed Energy Communications & Controls, Lab Activities - Summary

The purpose is to develop controls for inverter-based renewable and non-renewable distributed energy systems to provide local voltage, power and power quality support for loads and the power grid. The objectives are to (1) develop adaptive controls for inverter-based distributed energy (DE) systems when there are multiple inverters on the same feeder and (2) determine the impact of high penetration high seasonal energy efficiency ratio (SEER) air conditioning (A/C) units on power systems during sub-transmission faults which can result in an A/C compressor motor stall and assess how inverter-based DE can help to mitigate the stall event. The Distributed Energy Communications & Controls Laboratory (DECC) is a unique facility for studying dynamic voltage, active power (P), non-active power (Q) and power factor control from inverter-based renewable distributed energy (DE) resources. Conventionally, inverter-based DE systems have been designed to provide constant, close to unity power factor and thus not provide any voltage support. The DECC Lab interfaces with the ORNL campus distribution system to provide actual power system testing of the controls approach. Using mathematical software tools and the DECC Lab environment, we are developing and testing local, autonomous and adaptive controls for local voltage control and P & Q control for inverter-based DE. We successfully tested our active and non-active power (P,Q) controls at the DECC laboratory along with voltage regulation controls. The new PQ control along with current limiter controls has been tested on our existing inverter test system. We have tested both non-adaptive and adaptive control modes for the PQ control. We have completed several technical papers on the approaches and results. Electric power distribution systems are experiencing outages due to a phenomenon known as fault induced delayed voltage recovery (FIDVR) due to air conditioning (A/C) compressor motor stall. Local voltage collapse from FIDVR is occurring in part because modern air-conditioner and heat pump compressor motors are much more susceptible to stalling during a voltage sag or dip than older motors. These motors can stall in less than three cycles (0.05 s) when a fault, for example, on the sub-transmission system, causes voltage on the distribution system to sag to 70% or less of nominal. We completed a new test system for A/C compressor motor stall testing at the DECC Lab. The A/C Stall test system is being used to characterize when and how compressor motors stall under low voltage and high compressor pressure conditions. However, instead of using air conditioners, we are using high efficiency heat pumps. We have gathered A/C stall characterization data for both sustained and momentary voltage sags of the test heat pump. At low enough voltage, the heat pump stalls (compressor motor stops and draws 5-6 times normal current in trying to restart) due to low inertia and low torque of the motor. For the momentary sag, we are using a fast acting contactor/switch to quickly switch from nominal to the sagged voltage in cycles.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Spectral scheme for atomic structure calculations in density functional theory

In this study, we present a spectral scheme for atomic structure calculations in pseudopotential Kohn-Sham density functional theory. In particular, after applying an exponential transformation of the radial coordinates, we employ global polynomial interpolation on a Chebyshev grid, with derivative operators approximated using the Chebyshev differentiation matrix, and integrations using Clenshaw-Curtis quadrature. We demonstrate the accuracy and efficiency of the scheme through spin-polarized and unpolarized calculations for representative atoms, while considering local, semilocal, and hybrid exchange-correlation functionals. In particular, we find that $\mathcal{O}$(200) grid points are sufficient to achieve an accuracy of 1 microhartree in the eigenvalues for optimized norm conserving Vanderbilt pseudopotentials spanning the periodic table from atomic number Ζ = 1 to 83.

74 ATOMIC AND MOLECULAR PHYSICS↗

A Short-Term and High-Resolution System Load Forecasting Approach Using Support Vector Regression with Hybrid Parameters Optimization

This work proposes an approach for distribution system load forecasting, which aims to provide highly accurate short-term load forecasting with high resolution utilizing a support vector regression (SVR) based forecaster and a two-step hybrid parameters optimization method. Specifically, because the load profiles in distribution systems contain abrupt deviations, a data normalization is designed as the pretreatment for the collected historical load data. Then an SVR model is trained by the load data to forecast the future load. For better performance of SVR, a two-step hybrid optimization algorithm is proposed to determine the best parameters. In the first step of the hybrid optimization algorithm, a designed grid traverse algorithm (GTA) is used to narrow the parameters searching area from a global to local space. In the second step, based on the result of the GTA, particle swarm optimization (PSO) is used to determine the best parameters in the local parameter space. After the best parameters are determined, the SVR model is used to forecast the short-term load deviation in the distribution system.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Adaptive Control for Residential HVAC Systems to Support Grid Services

In this paper, we propose an adaptive control strategy for residential buildings' heating ventilation and air conditioning (HVAC) systems to support grid services. The proposed control strategy captures the time-varying characteristics of the building and weather environments. It assigns to each building a local controller to maintain the indoor temperature within a desired comfort level, while the load aggregator allocates the assigned reference power provided by the distribution system operator to support a specific grid service, such as demand peak reduction, balancing supply and demand, and consuming the solar photovoltaic (PV) power locally. Simulation results are presented to verify the performance of the proposed control strategy in terms of maintaining the indoor temperatures of several buildings within the desired comfort bands while tracking the reference power profile. Also, a comparison with a recently developed model-free control strategy is presented.

Wu, Tumin↗

Tracking Debris Shed by a Space-Shuttle Launch Vehicle

The DEBRIS software predicts the trajectories of debris particles shed by a space-shuttle launch vehicle during ascent, to aid in assessing potential harm to the space-shuttle orbiter and crew. The user specifies the location of release and other initial conditions for a debris particle. DEBRIS tracks the particle within an overset grid system by means of a computational fluid dynamics (CFD) simulation of the local flow field and a ballistic simulation that takes account of the mass of the particle and its aerodynamic properties in the flow field. The computed particle trajectory is stored in a file to be post-processed by other software for viewing and analyzing the trajectory. DEBRIS supplants a prior debris tracking code that took .15 minutes to calculate a single particle trajectory: DEBRIS can calculate 1,000 trajectories in .20 seconds on a desktop computer. Other improvements over the prior code include adaptive time-stepping to ensure accuracy, forcing at least one step per grid cell to ensure resolution of all CFD-resolved flow features, ability to simulate rebound of debris from surfaces, extensive error checking, a builtin suite of test cases, and dynamic allocation of memory.

Stuart, Phillip C.↗

Balmer-α spectrum measurements of the LHD one-third ion source

Wavelength spectra of Balmer-α light from plasmas in the extraction region of the Large Helical Device-R&D negative ion source, or the LHD one-third ion source have exhibited a blue shift as a negative bias voltage was applied to the plasma grid. The blue shift increased as the negative bias voltage with respect to the local plasma potential was increased. The measured spectra were compared with the velocity distributions of surface reflected hydrogen atoms calculated by atomic collisions in amorphous target code. The arc power and the source H{sub 2} pressure also affected the shift and broadening in the observed Balmer-α spectra. The possibility of identifying the negative hydrogen ions produced at the low work function plasma grid surface by high resolution spectroscopy is discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A Strategy for Forced Oscillation Suppression

Wide-area time-synchronized measurements have recently revealed troublesome forced oscillations (FOs) within modern synchronized power grids. In some cases, these FOs represent a dangerous hazard to the system. Recent research has focused on locating the source of FOs to provide operators with knowledge for mitigating their impact locally. This paper presents a complementary mitigation strategy, which is to purposely induce a second oscillation into the grid which cancels the impact of the FO. Such a strategy is complementary in that it may provide valuable time to operators attempting to locate the FOs source and to determine how to rectify it. This paper presents a suppression control strategy which modulates controllable devices to automatically cancel the impact of the FO without the need for locating the source of the original FO. The strategy is based upon tuned feedback control. In this study, the approach is demonstrated on a simulation system via modulation of inverter-based generation.

42 ENGINEERING↗

An exploratory study of finite difference grids for transonic unsteady aerodynamics

Unsteady aerodynamic forces are calculated by the XTRAN2L finite difference program which solves the complete two dimensional unsteady transonic small perturbation equation. The unsteady forces are obtained using a pulse transfer function technique which assumes the flow field behaves in a locally linear fashion about a mean condition. Forces are calculated for a linear flat plate using the default grids from the LTRAN2-NLR, LTRAN2-HI, and XTRAN3S programs. The forces are compared to the exact theoretical values for flat plate, and grid generated boundary and internal numerical reflections are observed to cause significant errors in the unsteady airloads. Grids are presented that alleviate the reflections while reducing computational time up to fifty-three percent and program size up to twenty-eight percent. Forces are presented for a six percent thick parabolic arc airfoil which demonstrate that the transform technique may be successfully applied to nonlinear transonic flows.

Seidel, D. A.↗

A 2D finite element wave equation solver based on triangular base elements

A finite element method based on the subdivision of the physical domain in triangular sub-domains in which simple local 'areale' coordinates are adopted is explored. The advantage of the method is that it straightforwardly allows grid refinement in regions where higher precision is required. The plasma model was kept simple for this 'proof-of-principle' exercise. Rather than accounting for the actual differential or integro-differential dielectric tensor, its locally uniform plasma equivalent was adopted for 3 possible choices: the cold plasma response, the full hot Stix/Swanson plasma tensor retaining all orders in finite Larmor radius (FLR) and the more common hot tensor, truncated at terms of second order in the Larmor radius.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗