Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “light source”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 847 records · Page 47

SAMRAI: A novel variably polarized angle-resolved photoemission beamline in the VUV region at UVSOR-II

A novel variably polarized angle-resolved photoemission spectroscopy beamline in the vacuum-ultraviolet (VUV) region has been installed at the UVSOR-II 750 MeV synchrotron light source. The beamline is equipped with a 3 m long APPLE-II type undulator with horizontally/vertically linear and right/left circular polarizations, a 10 m Wadsworth type monochromator covering a photon energy range of 6-43 eV, and a 200 mm radius hemispherical photoelectron analyzer with an electron lens of a {+-}18 deg. acceptance angle. Due to the low emittance of the UVSOR-II storage ring, the light source is regarded as an entrance slit, and the undulator light is directly led to a grating by two plane mirrors in the monochromator while maintaining a balance between high-energy resolution and high photon flux. The energy resolving power (h{nu}/{Delta}h{nu}) and photon flux of the monochromator are typically 1x10{sup 4} and 10{sup 12} photons/s, respectively, with a 100 {mu}m exit slit. The beamline is used for angle-resolved photoemission spectroscopy with an energy resolution of a few meV covering the UV-to-VUV energy range.

43 PARTICLE ACCELERATORS↗

Short x-ray pulse generation using deflecting cavities at the Advanced Photon Source.

Storage-ring-based third-generation light sources can provide intense radiation pulses with durations as short as 100 ps. However, there is growing interest within the synchrotron radiation user community in performing experiments with much shorter X-ray pulses. Zholents et al. [Nucl. Instr. and Meth. A 425 (1999) 385] recently proposed using RF orbit deflection to generate sub-ps X-ray pulses. In this scheme, two deflecting cavities are used to deliver a longitudinally dependent vertical kick to the beam. An optical slit can then be used to slice out a short part of the radiation pulse. Implementation of this scheme is planned for one APS beamline in the near future. In this paper, we summarize our feasibility study of this method and the expected X-ray beam parameters. We find that a pulse length of less than two picoseconds can be achieved.

43 PARTICLE ACCELERATORS↗

Demonstration of Transverse-to-Longitudinal Emittance Exchange at the Fermilab Photoinjector

Phase space manipulation techniques with two degrees of freedom could be essential to the enhancement of the performance of next generation accelerators such as high energy colliders and accelerator-based light sources. At the Fermilab A0 Photoinjector, a proof-of-principle experiment to demonstrate the exchange of the transverse and longitudinal emittance is ongoing. The emittance exchange (EEX) beamline consists of a 3.9 GHz normal conducting deflecting mode cavity positioned between two doglegs as proposed by Kim and Sessler. The experiment is performed using electron bunches with charge of 250 pC and energy of 14.3 MeV. The incoming electron beam has transverse emittance of 2-4 mm mrad and longitudinal emittance of 10-14 mm mrad. After the EEX the measured horizonal emittance is blown up to 13-15 mm mrad while the measured vertical emittance (Non EEX plane) stays the same. At the same time the longitudinal emittance is reduced to 7-9 mm mrad as measued by the current longitudinal diagnostic tools. A linear optics model is established using the beam matrix calculated and measured. A first order simulation based on this model is performed to compare to our experiment results for both EEX measurement and the phase space manipulation experiment.

43 PARTICLE ACCELERATORS↗

Scannerless laser range imaging using loss modulation

A scannerless 3-D imaging apparatus is disclosed which utilizes an amplitude modulated cw light source to illuminate a field of view containing a target of interest. Backscattered light from the target is passed through one or more loss modulators which are modulated at the same frequency as the light source, but with a phase delay .delta. which can be fixed or variable. The backscattered light is demodulated by the loss modulator and detected with a CCD, CMOS or focal plane array (FPA) detector to construct a 3-D image of the target. The scannerless 3-D imaging apparatus, which can operate in the eye-safe wavelength region 1.4-1.7 .mu.m and which can be constructed as a flash LADAR, has applications for vehicle collision avoidance, autonomous rendezvous and docking, robotic vision, industrial inspection and measurement, 3-D cameras, and facial recognition.

47 OTHER INSTRUMENTATION↗

A new dump system design for stray light reduction of Thomson scattering diagnostic system on EAST

Thomson scattering (TS) diagnostic is an important diagnostic for measuring electron temperature and density during plasma discharge. However, the measurement of Thomson scattering signal is disturbed by the stray light easily. The stray light sources in the Experimental Advanced Superconducting Tokamak (EAST) TS diagnostic system were analyzed by a simulation model of the diagnostic system, and simulation results show that the dump system is the primary stray light source. Based on the optics theory and the simulation analysis, a novel dump system including an improved beam trap was proposed and installed. The measurement results indicate that the new dump system can reduce more than 60% of the stray light for the diagnostic system, and the influence of stray light on the error of measured density decreases.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Optical sensor for measuring American Lobster vitality

The vitality of the American Lobster (Homarus americanus) is correlated to the total hemolymph protein (THP) in lobster hemolymph (blood). The standard technique for determining lobster vitality is to draw blood from a lobster and measure THP with a refractometer. This technique is invasive and endangers the lobster's health since blood must be drawn from the lobster. In the present work an optical sensor is developed to measure a lobster's vitality in vivo. It is comprised of a broadband light source, a monochromator, a fiber optic reflection probe, a spectrometer and a computer. This sensor measures protein concentrations by exciting a lobster with 280 nm and 334 nm wavelength light sources and measuring the corresponding absorbance peaks for THP and the fluorescence peak for hemocyanin (Hc), the majority protein in hemolymph. In this work several lobsters are tested. For each lobster, absorbance and fluorescence peaks are measured using the sensor and compared to protein concentrations measured using a refractometer. It is found that the shell thickness and muscle density, which correspond directly to protein concentration and the molting stage of the lobster have a significant effect on the absorbance and fluorescence measurements. It is also found that within specific molting stages, such as pre-molt and post-molt, protein concentration measured with a refractometer correlates linearly to absorbance and fluorescence measurements with the optical sensor.

60 APPLIED LIFE SCIENCES↗

X-ray free electron laser linear accelerator without a laser heater

Linear accelerator based X-ray free electron laser (FEL) light sources provide an important tool for scientific discoveries. Most of these light source facilities employ a laser heater to increase the electron beam’s uncorrelated energy spread to suppress microbunching instability through the linear accelerators. In this paper, we first studied the microbunching instability in an X-ray FEL linear accelerator with lower initial peak current (~ 10 A) and moderate final peak currents (1-2 kA). In this regime, the microbunching instability can be substantially mitigated with modest initial uncorrelated energy spread. Here, we then suggested a less expensive method to mitigate the microbunching instability using a section of low beta FODO lattice instead of the laser heater. With the use of the high brightness electron beam from a photoinjector, the intrabeam scattering effect inside the beam through the FODO lattice can generate sufficient uncorrelated energy spread to mitigate the microbunching instability. At last, we demonstrated the feasibility of this method with self-consistent solution of the Fokker–Planck equation through the X-ray FEL linear accelerator.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Fast Dynamic Aperture Optimization with Reversal Integration

A fast method for dynamic aperture (DA) optimization of storage rings has been developed through the use of reversal integration. Even if dynamical systems have an exact reversal symme- try, a numerical forward integration di ers from its reversal. For chaotic trajectories, cumulative round-o errors are scaled, which results in an exponential growth in the di erence. The exponential e ect, intrinsically associated with the Lyapunov exponent, is a generic indicator of chaos because it represents the sensitivity of chaotic motion to an initial condition. A chaos indicator of the charged particle motion is then obtained by comparing the forward integrations of particle trajectories with corresponding reversals, a.k.a. \backward integrations." The indicator was con rmed to be ob- servable through short-term particle tracking simulations. Therefore, adopting it as an objective function could speed up optimization. The DA of the National Synchrotron Light Source II storage ring, and another test di raction-limited light source ring, were optimized using this method for the purpose of demonstration.

36 MATERIALS SCIENCE↗

LCLS-II: The Next Leap for X-Ray Science

This movie introduces LCLS-II, a future light source at SLAC. It will generate over 8,000 times more light pulses per second than today’s most powerful X-ray laser, LCLS, and produce an almost continuous X-ray beam that on average will be 10,000 times brighter. These unrivaled capabilities will help researchers address a number of grand challenges in science by capturing detailed snapshots of rapid processes that are beyond the reach of other light sources.

43 PARTICLE ACCELERATORS↗

Apparatus and method for OSL-based, remote radiation monitoring and spectrometry

Compact, OSL-based devices for long-term, unattended radiation detection and spectroscopy are provided. In addition, a method for extracting spectroscopic information from these devices is taught. The devices can comprise OSL pixels and at least one radiation filter surrounding at least a portion of the OSL pixels. The filter can modulate an incident radiation flux. The devices can further comprise a light source and a detector, both proximally located to the OSL pixels, as well as a power source and a wireless communication device, each operably connected to the light source and the detector. Power consumption of the device ranges from ultra-low to zero. The OSL pixels can retain data regarding incident radiation events as trapped charges. The data can be extracted wirelessly or manually. The method for extracting spectroscopic data comprises optically stimulating the exposed OSL pixels, detecting a readout luminescence, and reconstructing an incident-energy spectrum from the luminescence.

47 OTHER INSTRUMENTATION↗

Angle-resolved photon-coincidence measurements in a multiple-scattering medium

We present angle-resolved correlation measurements between photons after propagation through a three-dimensional disordered medium. The multiple-scattering process induces photon correlations that are directly measured for light sources with different photon statistics. We find that multiple-scattered photons between different angular directions with angles much larger than the average speckle width are strongly correlated. The time dependence of the angular photon correlation function is investigated, and the coherence time of the light source is determined. Our results are found to be in excellent agreement with the continuous mode quantum theory of multiple scattering of light. The presented experimental technique is essential in order to study quantum phenomena in multiple-scattering random media, such as quantum interference and quantum entanglement of photons.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SU-C-303-04: Evaluation of On- and Off-Line Bioluminescence Tomography System for Focal Irradiation Guidance

Purpose: We have developed offline and on-board bioluminescence tomography(BLT) systems for the small animal radiation research platform(SARRP) for radiation guidance of soft tissue targets. We investigated the effectiveness of offline BLT guidance. Methods: CBCT is equipped on both the offline BLT system and SARRP that are 10 ft. apart. To evaluate the setup error during animal transport between the two systems, we implanted a luminescence source in the abdomen of anesthetized mice. Five mice were studied. After CBCT was acquired on both systems, source centers and correlation coefficients were calculated. CBCT was also used to generate object mesh for BLT reconstruction. To assess target localization, we compared the localization of the luminescence source based on (1)on-board SARRP BLT and CBCT, (2)offline BLT and CBCT, and (3)offline BLT and SARRP CBCT. The 3rd comparison examines if an offline BLT system can be used to guide radiation when there is minimal target contrast in CBCT. Results: Our CBCT results show the offset of the light source center can be maintained within 0.2 mm during animal transport. The center of mass(CoM) of the light source reconstructed by the offline BLT has an offset of 1.0 ± 0.4 mm from the ‘true’ CoM as derived from the SARRP CBCT. The results compare well with the offset of 1.0 ± 0.2 mm using on-line BLT. Conclusion: With CBCT information provided by the SARRP and effective animal immobilization during transport, these findings support the use of offline BLT in close vicinity for accurate soft tissue target localization for irradiation. However, the disadvantage of the off-line system is reduced efficiency as care is required to maintain stable animal transport. We envisage a dual use system where the on-board arrangement allows convenient access to CBCT and avoids disturbance of animal setup. The off-line capability would support standalone longitudinal imaging studies. The work is supported by NIH R01CA158100 and Xstrahl Ltd. Drs. John Wong and Iulian Iordachita receive royalty payment from a licensing agreement between Xstrahl Ltd and Johns Hopkins University. John Wong also has a consultant agreement with Xstrahl Ltd.

60 APPLIED LIFE SCIENCES↗

Demonstration Assessment of Light Emitting Diode (LED) Commercial Garage Lights In the Providence Portland Medical Center, Portland, Oregon

This U.S. Department of Energy GATEWAY Demonstration project studied the applicability of light-emitting diode (LED) luminaires for commercial parking garage applications. High-pressure sodium (HPS) area luminaires were replaced with new LED area luminaires. The project was supported under the U.S. Department of Energy (DOE) Solid State Lighting Program. Other participants in the demonstration project included Providence Portland Medical Center in Portland, Oregon, the Energy Trust of Oregon, and Lighting Sciences Group (LSG) Inc. Pacific Northwest National Laboratory (PNNL) conducted the measurements and analysis of the results. PNNL manages GATEWAY demonstrations for DOE and represents their perspective in the conduct of the work. Quantitative and qualitative measurements of light and electrical power were taken at the site for both HPS and LED light sources. Economic costs were estimated and garage users’ responses to the new light sources were gauged with a survey. Six LED luminaires were installed in the below-ground parking level A, replacing six existing 150W HPS lamps spread out over two rows of parking spaces. Illuminance measurements were taken at floor level approximately every 4 ft on a 60-ft x 40-ft grid to measure light output of these LED luminaires which were termed the “Version 1” luminaires. PNNL conducted power measurements of the circuit in the garage to which the 6 luminaires were connected and determined that they drew an average of 82 W per lamp. An improved LED luminaire, Version 2, was installed in Level B of the parking garage. Illuminance measurements were not made of this second luminaire on site due to higher traffic conditions, but photometric measurements of this lamp and Version 1 were made in an independent testing laboratory and power usage for Version 2 was also measured. Version 1 was found to produce 3600 lumens and Version 2 was found to produce 4700 lumens of light and to consume 78 Watts. Maximum and minimum light levels were measured for the HPS and LED Version 1 luminaires and projected for the Version 2 luminaires. Maximum light levels were 23.51 foot candles, 20.54 fc, and 26.7 fc respectively and minimum light levels were 1.49 fc, 1.45 fc, and 1.88 fc. These results indicate very similar or even slightly higher light levels produced by the LED lamps, despite the higher lumen output of the HPS lamp. The LED lamps provide higher luminaire efficacy because all of the light is directed down and out. None of it is “lost” in the fixture. Also the HPS luminaire had poorly designed optics and a plastic covering that tended to get dirty and cracked, further decreasing the realized light output.[is this an accurate way to say this?] Consumer perceptions of the Version 2 LED were collected via a written survey form given to maintenance and security personnel. More than half felt the LED luminaires provided more light than the HPS lamps and a majority expressed a preference for the new lamps when viewing the relamped area through a security camera. Respondents commented that the LED luminaires were less glary, created less shadows, had a positive impact on visibility, and improved the overall appearance of the area. PNNL conducted an economic analysis and found that the Version 1 lamp produced annual energy savings of 955 kWh and energy cost savings of $76.39 per lamp at electricity rates of 6.5 cents per kWh and $105.03 at 11 cents per kWh. PNNL found that the Version 2 lamp produced annual energy savings of 991 kWh and energy cost savings of $79.26 per lamp at electricity rates of 6.5 cents per kWh and $108.98 at 11 cents per kWh. PNNL also calculated simple payback and found that Version 1 showed paybacks of 5.4 yrs at 6.5c/kWh and 4.1 yrs at 11c/kWh while Version 2 showed paybacks of 5.2 yrs at 6.5c/kWh and 3.9 yrs at 11c/kWh.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Intracluster light in clusters of galaxies at redshifts $0.4 < z < 0.8$

The study of intracluster light can help us to understand the mechanisms taking place in galaxy clusters, and to place constraints on the cluster formation history and physical properties. However, owing to the intrinsic faintness of ICL emission, most searches and detailed studies of ICL have been limited to redshifts z<0.4.We search for ICL in a subsample of ten clusters detected by the ESO Distant Cluster Survey (EDisCS), at redshifts 0.4<z<0.8, that are also part of our DAFT/FADA Survey. We analyze the ICL by applying the OV WAV package, a wavelet-based technique, to deep HST ACS images in the F814W filter and to V-band VLT/FORS2 images of three clusters. Detection levels are assessed as a function of the diffuse light source surface brightness using simulations. In the F814W filter images, we detect diffuse light sources in all the clusters, with typical sizes of a few tens of kpc (assuming that they are at the cluster redshifts). The ICL detected by stacking the ten F814W images shows an 8sigma detection in the source center extending over a ~50x50kpc2 area, with a total absolute magnitude of -21.6 in the F814W filter, equivalent to about two L* galaxies per cluster. We find a weak correlation between the total F814W absolute magnitude of the ICL and the cluster velocity dispersion and mass. There is no apparent correlation between the cluster mass-to-light ratio (M/L) and the amount of ICL, and no evidence for any preferential orientation in the ICL source distribution. We find no strong variation in the amount of ICL between z=0 and z=0.8. In addition, we find wavelet-detected compact objects (WDCOs) in the three clusters for which data in two bands are available; these objects are probably very faint compact galaxies that in some cases are members of the respective clusters. We have shown that ICL is important in clusters at least up to z=0.8.

79 ASTRONOMY AND ASTROPHYSICS↗

Optimization of Dynamic Aperture of PEP-X Baseline Design

SLAC is developing a long-range plan to transfer the evolving scientific programs at SSRL from the SPEAR3 light source to a much higher performing photon source. Storage ring design is one of the possibilities that would be housed in the 2.2-km PEP-II tunnel. The design goal of PEPX storage ring is to approach an optimal light source design with horizontal emittance less than 100 pm and vertical emittance of 8 pm to reach the diffraction limit of 1-{angstrom} x-ray. The low emittance design requires a lattice with strong focusing leading to high natural chromaticity and therefore to strong sextupoles. The latter caused reduction of dynamic aperture. The dynamic aperture requirement for horizontal injection at injection point is about 10 mm. In order to achieve the desired dynamic aperture the transverse non-linearity of PEP-X is studied. The program LEGO is used to simulate the particle motion. The technique of frequency map is used to analyze the nonlinear behavior. The effect of the non-linearity is tried to minimize at the given constrains of limited space. The details and results of dynamic aperture optimization are discussed in this paper.

43 PARTICLE ACCELERATORS↗

Use Patterns of LED Flashlights in Kenya and a One-Year Cost Analysis of Flashlight Ownership

Flashlight usage is widespread across much of sub-Saharan Africa.1 In Kenya in particular, over half of all households report owning a flashlight (Kamfor, 2002). Aside from household use, flashlights are also widely used to perform income-earning jobs in Kenya. Lumina Research Note No.4, the first report in this series documenting flashlight use in Kenya, highlights flashlight use patterns of night watchmen and bicycle taxi drivers. Both of these are occupations that rely on the use of flashlights on a nightly basis (Tracy et al., 2009). Also highlighted by Research Note No.4, flashlight users in Kenya have reported being highly dissatisfied with the quality of the low-cost LED flashlights that are available, and they identify several reoccurring problems they have faced as flashlight end-users (Tracy et al., 2009). The fact that there exists a substantial dependency upon flashlights in Kenya and that users are disgruntled with the available products suggests reasons for concern about flashlight quality. This concern is present despite two recent technological transitions in the flashlight market. First, LED technology has quickly emerged as the dominant source of portable lighting in Kenya, outpacing incandescent flashlights (Johnstone et al., 2009). LED technology has the potential to provide efficiency and performance benefits relative to incandescent bulbs, and low-cost LEDs have achieved price levels that make them cost competitive with conventional lighting sources for a number of applications (Mills, 2005). Second, rechargeable sealed-lead acid (SLA) batteries are also becoming more prevalent alternatives to disposable dry cell batteries. Flashlights using rechargeable SLA batteries tend to have a lower total cost of ownership over a two-year period than a flashlight using dry cell batteries (Radecsky, 2009); however, as this current report highlights, this may vary depending on the intensity of use patterns. To avoid a potential market spoiling effect for off-grid lighting products based on LED technology (Mills and Jacobson, 2008; Lighting Africa, 2007) a better understanding of flashlight use-patterns is crucial (Tracy et al., 2009). In addition, the economic implications faced by rural flashlight end-users provide further incentive for a move toward higher quality low-cost flashlights. In this report, our team uses interviews with 46 end users of flashlights to collect information about their use patterns and costs associated with owning and operating flashlight products. While flashlights used in their portable mode typically do not represent a substitute for kerosene or other forms of fuel-based lighting, at times they are used in stationary applications in place of a fuel-based lamp. In either case, these products often represent end users first exposure to LED technology and rechargeable dry cell batteries, and thus stand to either provide a positive or negative impression of these technologies for a diversity of lighting applications.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Compton Polarimetry at ELSA

Part of the future polarization program performed at the Bonn accelerator facility ELSA will rely on precision Compton polarimetry of the stored transversely polarized electron beam. Precise and fast polarimetry poses high demands on the light source and the detector which were studied in detail performing numerical simulations of the Compton scattering process. In order to experimentally verify these calculations, first measurements were carried out using an argon ion laser as light source and a prototype version of a counting silicon microstrip detector. Calculated and measured intensity profiles of backscattered photons are presented and compared, showing excellent agreement. Background originating from beam gas radiation turned out to be the major limitation of the polarimeter performance. In order to improve the situation, a new polarimeter was constructed and is currently being set up. Design and expected performance of this polarimeter upgrade are presented.

43 PARTICLE ACCELERATORS↗