Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “insertion”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 847 records · Page 47

Comparison of heat flux measurement techniques during the DIII-D metal ring campaign

The heat fluxes expected in the ITER divertor raise concerns about the damage tolerances of tungsten, especially due to thermal transients caused by edge localized modes (ELMs) as well as frequent temperature cycling from high to low extremes. Thus we are motivated to understand the heat flux conditions that can cause not only enhanced erosion but also bulk thermo-mechanical damage to a tungsten divertor. For the metal ring campaign in DIII-D, tungsten-coated TZM tile inserts were installed making two toroidal arrays of metal tile inserts in the lower divertor. This study examines the deposited heat flux on these rings with embedded thermocouples (TCs) sampling at 10 kHz and compares them to Langmuir probe (LP) and infrared thermography (IRTV) heat flux measurements. We see agreement of the TC, LP, and IRTV data within 20% of the heat flux averaged over the entire discharge, and that all three diagnostics suggest parallel heat flux at the OSP location increases linearly with input heating power. The TC and LP heat flux time traces during the discharge trend together during large changes to the average heat flux. By subtracting the LP measured inter-ELM heat flux from TC data, using a rectangular ELM energy pulse shape, and taking the relative size and duration of each ELM from ${{D}}_{\alpha }$ measurements, we extract the ELM heat fluxes from TC data. This over-estimates the IRTV measured ELM heat fluxes by a factor of 1.9, and could be due to the simplicity of the TC heat flux model and the assumed ELM energy pulse shape. ELM heat fluxes deposited on the inserts are used to model tungsten erosion in this campaign. These TC ELM heat flux estimates are used in addition to IRTV, especially in cases where the IRTV view to the metal ring is obstructed. We observe that some metal inserts were deformed due to exposed leading edges. The thermal conditions on these inserts are investigated with the thermal modeling code ABAQUS using our heat flux measurements when these edges were exposed. We report on how the thermal cycling on the ends of the inserts caused this deformation.

42 ENGINEERING↗

Studying of B{sub s{yields}}K{sup (* )-{pi}+}, K{sup (*)-{rho}+} decays within supersymmetry

Recent results from the CDF Collaboration favor a large CP asymmetry in B{sub s{yields}}K{sup -{pi}+} decay, while the standard model prediction is very small. Moreover, the measurement of its branching ratio is lower than the standard model prediction based on the QCD factorization. We compute the gluino-mediated supersymmetry contributions to B{sub s{yields}}K{sup (*)-{pi}+}, K{sup (*)-{rho}+} decays in the framework of the mass insertion method, and find that for (m{sub g}-tilde){sup 2}/m{sub q}-tilde{sup 2}){<=}2, the theoretical predictions including the LR and RL mass insertion contributions are compatible with the measurements of B{sub s{yields}}K{sup -{pi}+} decay and B{sup 0}-B{sup 0} mixing within 2{sigma} ranges. Using the constrained LR and RL mass insertion parameter spaces, we explore the supersymmetry mass insertion effects on the branching ratios, the direct CP asymmetries, and the polarization fractions in B{sub s{yields}}K*{sup -{pi}+}, K{sup -{rho}+}, K*{sup -{rho}+} decays. We find the constrained LR and RL insertions can provide sizable contributions to the branching ratios of B{sub s{yields}}K*{sup -{pi}+}, K{sup (*)-{rho}+} as well as the direct CP asymmetry and the longitudinal polarization of B{sub s{yields}}K*{sup -{rho}+} decay without conflict with all related data within 2{sigma} ranges. Near future experiments at Fermi Lab and CERN LHC-b can test our predictions and shrink/reveal the mass insertion parameter spaces.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Evaluation of normalized metal artifact reduction (NMAR) in kVCT using MVCT prior images for radiotherapy treatment planning

Purpose: To evaluate the metal artifacts in kilovoltage computed tomography (kVCT) images that are corrected using a normalized metal artifact reduction (NMAR) method with megavoltage CT (MVCT) prior images.Methods: Tissue characterization phantoms containing bilateral steel inserts are used in all experiments. Two MVCT images, one without any metal artifact corrections and the other corrected using a modified iterative maximum likelihood polychromatic algorithm for CT (IMPACT) are translated to pseudo-kVCT images. These are then used as prior images without tissue classification in an NMAR technique for correcting the experimental kVCT image. The IMPACT method in MVCT included an additional model for the pair/triplet production process and the energy dependent response of the MVCT detectors. An experimental kVCT image, without the metal inserts and reconstructed using the filtered back projection (FBP) method, is artificially patched with the known steel inserts to get a reference image. The regular NMAR image containing the steel inserts that uses tissue classified kVCT prior and the NMAR images reconstructed using MVCT priors are compared with the reference image for metal artifact reduction. The Eclipse treatment planning system is used to calculate radiotherapy dose distributions on the corrected images and on the reference image using the Anisotropic Analytical Algorithm with 6 MV parallel opposed 5 × 10 cm{sup 2} fields passing through the bilateral steel inserts, and the results are compared. Gafchromic film is used to measure the actual dose delivered in a plane perpendicular to the beams at the isocenter.Results: The streaking and shading in the NMAR image using tissue classifications are significantly reduced. However, the structures, including metal, are deformed. Some uniform regions appear to have eroded from one side. There is a large variation of attenuation values inside the metal inserts. Similar results are seen in commercially corrected image. Use of MVCT prior images without tissue classification in NMAR significantly reduces these problems. The radiation dose calculated on the reference image is close to the dose measured using the film. Compared to the reference image, the calculated dose difference in the conventional NMAR image, the corrected images using uncorrected MVCT image, and IMPACT corrected MVCT image as priors is ∼15.5%, ∼5%, and ∼2.7%, respectively, at the isocenter.Conclusions: The deformation and erosion of the structures present in regular NMAR corrected images can be largely reduced by using MVCT priors without tissue segmentation. The attenuation value of metal being incorrect, large dose differences relative to the true value can result when using the conventional NMAR image. This difference can be significantly reduced if MVCT images are used as priors. Reduced tissue deformation, better tissue visualization, and correct information about the electron density of the tissues and metals in the artifact corrected images could help delineate the structures better, as well as calculate radiation dose more correctly, thus enhancing the quality of the radiotherapy treatment planning.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Generation of virtual monochromatic CBCT from dual kV/MV beam projections

Purpose: To develop a novel on-board imaging technique which allows generation of virtual monochromatic (VM) cone-beam CT (CBCT) with a selected energy from combined kilovoltage (kV)/megavoltage (MV) beam projections. Methods: With the current orthogonal kV/MV imaging hardware equipped in modern linear accelerators, both MV projections (from gantry angle of 0°–100°) and kV projections (90°–200°) were acquired as gantry rotated a total of 110°. A selected range of overlap projections between 90° to 100° were then decomposed into two material projections using experimentally determined parameters from orthogonally stacked aluminum and acrylic step-wedges. Given attenuation coefficients of aluminum and acrylic at a predetermined energy, one set of VM projections could be synthesized from two corresponding sets of decomposed projections. Two linear functions were generated using projection information at overlap angles to convert kV and MV projections at nonoverlap angles to approximate VM projections for CBCT reconstruction. The contrast-to-noise ratios (CNRs) were calculated for different inserts in VM CBCTs of a CatPhan phantom with various selected energies and compared with those in kV and MV CBCTs. The effect of overlap projection number on CNR was evaluated. Additionally, the effect of beam orientation was studied by scanning the CatPhan sandwiched with two 5 cm solid-water phantoms on both lateral sides and an electronic density phantom with two metal bolt inserts. Results: Proper selection of VM energy [30 and 40 keV for low-density polyethylene (LDPE), polymethylpentene, 2 MeV for Delrin] provided comparable or even better CNR results as compared with kV or MV CBCT. An increased number of overlap kV and MV projection demonstrated only marginal improvements of CNR for different inserts (with the exception of LDPE) and therefore one projection overlap was found to be sufficient for the CatPhan study. It was also evident that the optimal CBCT image quality was achieved when MV beams penetrated through the heavy attenuation direction of the object. Conclusions: A novel technique was developed to generate VM CBCTs from kV/MV projections. This technique has the potential to improve CNR at selected VM energies and to suppress artifacts at appropriate beam orientations.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Investigating the accuracy of microstereotactic-body-radiotherapy utilizing anatomically accurate 3D printed rodent-morphic dosimeters

Purpose: Sophisticated small animal irradiators, incorporating cone-beam-CT image-guidance, have recently been developed which enable exploration of the efficacy of advanced radiation treatments in the preclinical setting. Microstereotactic-body-radiation-therapy (microSBRT) is one technique of interest, utilizing field sizes in the range of 1–15 mm. Verification of the accuracy of microSBRT treatment delivery is challenging due to the lack of available methods to comprehensively measure dose distributions in representative phantoms with sufficiently high spatial resolution and in 3 dimensions (3D). This work introduces a potential solution in the form of anatomically accurate rodent-morphic 3D dosimeters compatible with ultrahigh resolution (0.3 mm{sup 3}) optical computed tomography (optical-CT) dose read-out. Methods: Rodent-morphic dosimeters were produced by 3D-printing molds of rodent anatomy directly from contours defined on x-ray CT data sets of rats and mice, and using these molds to create tissue-equivalent radiochromic 3D dosimeters from Presage. Anatomically accurate spines were incorporated into some dosimeters, by first 3D printing the spine mold, then forming a high-Z bone equivalent spine insert. This spine insert was then set inside the tissue equivalent body mold. The high-Z spinal insert enabled representative cone-beam CT IGRT targeting. On irradiation, a linear radiochromic change in optical-density occurs in the dosimeter, which is proportional to absorbed dose, and was read out using optical-CT in high-resolution (0.5 mm isotropic voxels). Optical-CT data were converted to absolute dose in two ways: (i) using a calibration curve derived from other Presage dosimeters from the same batch, and (ii) by independent measurement of calibrated dose at a point using a novel detector comprised of a yttrium oxide based nanocrystalline scintillator, with a submillimeter active length. A microSBRT spinal treatment was delivered consisting of a 180° continuous arc at 225 kVp with a 20 × 10 mm field size. Dose response was evaluated using both the Presage/optical-CT 3D dosimetry system described above, and independent verification in select planes using EBT2 radiochromic film placed inside rodent-morphic dosimeters that had been sectioned in half. Results: Rodent-morphic 3D dosimeters were successfully produced from Presage radiochromic material by utilizing 3D printed molds of rat CT contours. The dosimeters were found to be compatible with optical-CT dose readout in high-resolution 3D (0.5 mm isotropic voxels) with minimal artifacts or noise. Cone-beam CT image guidance was possible with these dosimeters due to sufficient contrast between high-Z spinal inserts and tissue equivalent Presage material (CNR ∼10 on CBCT images). Dose at isocenter measured with optical-CT was found to agree with nanoscintillator measurement to within 2.8%. Maximum dose in line profiles taken through Presage and film dose slices agreed within 3%, with FWHM measurements through each profile found to agree within 2%. Conclusions: This work demonstrates the feasibility of using 3D printing technology to make anatomically accurate Presage rodent-morphic dosimeters incorporating spinal-mimicking inserts. High quality optical-CT 3D dosimetry is feasible on these dosimeters, despite the irregular surfaces and implanted inserts. The ability to measure dose distributions in anatomically accurate phantoms represents a powerful useful additional verification tool for preclinical microSBRT.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-E-J-226: Efficient Use of Computed Tomography (CT) and Magnetic Resonance Imaging (MRI) for Cervical-Cancer Brachytherapy

Purpose: To investigate image modality selection in an environment with limited access to interventional MRI for image-guided high-dose-rate cervical-cancer brachytherapy. Methods: Records of all cervical-cancer patients treated with brachytherapy between 1/2013 and 8/2014 were analyzed. Insertions were performed under CT guidance (CT group) or with >1 fraction under 3T MR guidance (MRI group; subMRI includes only patients who also had a CT-guided insertion). Differences between groups in clinical target volume (CTV), disease stage (I/II or III/IV), number of patients with or without interstitial needles, and CTV D90 were investigated. Statistical significance was evaluated with the Student T test and Fisher test (p <0.05). Results: 46 cervical-cancer patients were included (16 MRI [3 subMRI], 30 CT). CTV: overall, 55±53 cm3; MRI, 81±61 cm3; CT, 42±44 cm3 (p = 0.017). Stage: overall, 24 I/II and 22 III/IV; MRI, 3 I/II and 13 III/IV; CT, 21 I/II and 9 III/IV (p = 0.002). Use of needles: overall, 26 without and 20 with; MRI, 5 without and 11 with; CT, 21 without and 9 with (p = 0.015). CTV D90: overall, 82±5 Gy; MRI, 81±6 Gy; CT, 82±5 Gy (p = 0.78). SubMRI: CTV and D90 (as % of nominal fraction dose) were 23±6 cm3 and 124±3% for MRI-guided insertions and 21±5 cm3 (p = 0.83) and 106±12% (p = 0.15) for CT-guided insertions. Conclusion: Statistically significant differences in patient population indicate preferential use of MRI for patients with high-stage disease and large residual CTVs requiring the use of interstitial needles. CTV D90 was similar between groups, despite the difference in patient selection. For patients who underwent both CT and MRI insertions, a larger MR CTV D90 and similar CTVs between insertions were observed. While MRI is generally preferable to CT, MRI selection can be optimized in environments without a dedicated MRI brachytherapy suite. This work was partially funded by the NIH R21 CA167800 (PI: Viswanathan; aviswanathan@partners.org)

60 APPLIED LIFE SCIENCES↗

SU-F-BRA-04: Prostate HDR Brachytherapy with Multichannel Robotic System

Purpose: High-dose-rate (HDR) brachytherapy is gradually becoming popular in treating patients with prostate cancers. However, placement of the HDR needles at desired locations into the patient is challenging. Application of robotic system may improve the accuracy of the clinical procedure. This experimental study is to evaluate the feasibility of using a multichannel robotic system for prostate HDR brachytherapy. Methods: In this experimental study, the robotic system employed was a 6-DOF Multichannel Image-guided Robotic Assistant for Brachytherapy (MIRAB), which was designed and fabricated for prostate seed implantation. The MIRAB has the provision of rotating 16 needles while inserting them. Ten prostate HDR brachytherapy needles were simultaneously inserted using MIRAB into a commercially available prostate phantom. After inserting the needles into the prostate phantom at desired locations, 2mm thick CT slices were obtained for dosimetric planning. HDR plan was generated using Oncetra planning system with a total prescription dose of 34Gy in 4 fractions. Plan quality was evaluated considering dose coverage to prostate and planning target volume (PTV), with 3mm margin around prostate, as well as the dose limit to the organs at risk (OARs) following the American Brachytherapy Society (ABS) guidelines. Results: From the CT scan, it is observed that the needles were inserted straight into the desired locations and they were adequately spaced and distributed for a clinically acceptable HDR plan. Coverage to PTV and prostate were about 91% (V100= 91%) and 96% (V100=96%), respectively. Dose to 1cc of urethra, rectum, and bladder were within the ABS specified limits. Conclusion: The MIRAB was able to insert multiple needles simultaneously into the prostate precisely. By controlling the MIRAB to insert all the ten utilized needles into the prostate phantom, we could achieve the robotic HDR brachytherapy successfully. Further study for assessing the system’s performance and reliability is in progress.

60 APPLIED LIFE SCIENCES↗

Improving the sampling efficiency of the Grand Canonical Simulated Quenching approach

Most common atomistic simulation techniques, like molecular dynamics or Metropolis Monte Carlo, operate under a constant interatomic Hamiltonian with a fixed number of atoms. Internal (atom positions or velocities) or external (simulation cell size or geometry) variables are then evolved dynamically or stochastically to yield sampling in different ensembles, such as microcanonical (NVE), canonical (NVT), isothermal-isobaric (NPT), etc. Averages are then taken to compute relevant physical properties. At least two limitations of these standard approaches can seriously hamper their application to many important systems: (1) they do not allow for the exchange of particles with a reservoir, and (2) the sampling efficiency is insufficient to allow the obtention of converged results because of the very long intrinsic timescales associated with these quantities. To fix ideas, one might want to identify low (free) energy configurations of grain boundaries (GB). In reality, grain boundaries are in contact the grains which act as reservoirs of defects (e.g., vacancies and interstitials). Since the GB can exchange particles with its environment, the most stable configuration cannot provably be found by sampling from NVE or NVT ensembles alone: one needs to allow the number of atoms in the sample to fluctuate. The first limitation can be circumvented by working in the grand canonical ensemble (TV ) or its derivatives (such as the semi-grand-canonical ensemble useful for the study of substitutional alloys). Monte Carlo methods have been the first to adapt to this kind of system where the number of atoms is allowed to fluctuate. Many of these methods are based on the Widom insertion method [Widom63] where the chemical potential of a given chemical species can be inferred from the potential energy changes upon random insertion of a new particle within the simulation cell. Other techniques, such as the Gibbs ensemble Monte Carlo [Panagiotopoulos87] where exchanges of particles are attempted to equilibrate the chemical potential between two cells and hence allow for the calculation of coexistence curves, exploit the same idea: particle insertion (or exchange) is attempted and accepted with a Metropolis-like rule that depends exponentially on the energy change upon insertion. A well known limitation of this kind of approach is that the probability of accepting such a move decreases extremely rapidly with increasing density, due to the extremely large short-range repulsion between atoms. In response to these difficulties it became apparent that a solution to the problem might be to avoid abrupt insertions but instead to proceed gradually, so as to allow the system to react and make way for the incoming particle. In this view of things, the 'occupation' of a certain atomic site can be viewed as a continuous variable, ranging between 0 and 1, representing 'how much' of the particle is present at any given time. These ideas proved ideal in Molecular Dynamics (MD) settings because equations of motions for these occupation variables can sometimes be obtained. For example, in the case of Grand Canonical Molecular Dynamics [Cagin91], one special particle is allowed to have a fractional occupation. This can lead to either its destruction (occupation = 0) or its complex creation (occupation = 1) so as to enforce a given chemical potential. These approaches proved useful, but mostly in the liquid state where the probability of successfully inserting a new particle is sufficiently high. At higher densities, convergence proved to be hampered by very inefficient sampling. In this work, we explore the use of a related MD-based grand canonical technique, the Grand Canonical Simulated Quenching (GCSQ) of Phillpot and Rickman [Phillpot92,Phillpot94], and explore its application to the grand canonical sampling of solid state systems. We show that, in conjunction with advanced sampling techniques, GCSQ can be a useful tool to sample conformations of complex systems, such as GBs, and assist in the identification of their most stable states and/or most likely defective states.

36 MATERIALS SCIENCE↗

Two-Piece Compaction Die Design

ORNL/TM-2010/48 described some results from using the finite element program ANSYS to determine the design geometry for compaction dies used to create europium oxide and tantalum control plates. Because of some discrepancies between the final drawings of the parts and the TM analyses, the models were reworked and some design modifications were made. When the mesh density was increased, increasing the number of elements in the model, especially near the corners, the maximum stresses in the corners were found to be higher than in the previous study. The dies needed to be designed with inner corner radii and interference fits that would allow the necessary compression force to create the plates but not exceed the yield strength of the material. Also, modeling was done to determine the effects of loading the dies asymmetrically in the axial direction, as this would make the plate extraction process easier while increasing the stress in the corners. The results show that for the tantalum die, a diametrical interference fit of 0.0020 in. between the outer ring and the insert is acceptable, and the inner corner radius can be as small as 0.0035 in. The insert has an outer diameter of 6.150 in. The cavity in the insert is 3.4640 $\times$ 0.8086 ± 0.002 in. and the outer ring has an outer diameter of 8.150 in. The die is 2.960 in. deep. With these design parameters, the plate can be formed so that its edge is 0.500 in. from the top or the bottom of the die, and the maximum stress everywhere in the die will be less than the yield strength of the materials. For the europium oxide die, the diametrical interference fit between the outer ring and the insert must be between 0.0075 and 0.0080 in. The inner corner radius can be as small as 0.0055 in. The insert has an outer diameter of 5.960 in. The cavity in the insert is 3.4552 $\times$ 1.7246 ± 0.002 in. and the outer ring has an outer diameter of 8.150 in. The die is 3.020 in. deep. With these design parameters, the plate can be formed so that its edge is 1.225 in. from the top or the bottom of the die.

42 ENGINEERING↗

Flake Formation in Phase Layers of a Cutting Ceramic

Flake formation (cracking) is observed in inserts of untreated cutting ceramic and also during diffusional strengthening of the inserts’ surface layer by nitrogen on heating in a muffle furnace to 450–500°C, with the creation of γ-phase (a protective layer), the removal of carbon from the atomic cells, and the formation of titanium nitride. Heat-treatment conditions for inserts of cutting ceramic are established such that the flake content at their surface is reduced. Treatment to prevent flake formation is proposed: heating in a sealed muffle furnace with a nitrogen atmosphere to 250–280°C at a pressure of 0.25 MPa. In this process, the titanium carbide at the surface of the inserts is converted to titanium nitride as a result of carbon diffusion, with the formation of a protective γ-phase layer. By removing carbon from the surface layer of the inserts and ensuring the diffusion of nitrogen into the cutting ceramic, with the formation of titanium nitride in the γphase, the durability and performance of the inserts are improved, along with their mechanical properties.

36 MATERIALS SCIENCE↗

Combinatorial design of chemical-dependent protein switches for controlling intracellular electron transfer

One concern with controlling electron flow in cells is the lack of biomolecules that directly couple the sensing of environmental conditions to electron transfer efficiency. To overcome this protein component limitation, we randomly inserted the ligand binding domain (LBD) from the human estrogen receptor (ER) into a thermostable 2Fe-2S ferredoxin (Fd) from Mastigocladus laminosus and used a bacterial selection to identify Fd-LBD fusion proteins that support electron transfer from a Fd-NADP reductase (FNR) to a Fd-dependent sulfite reductase (SIR). Mapping LBD insertion sites onto structure revealed that Fd tolerates domain insertion adjacent to or within the tetracysteine motif that coordinates the 2Fe-2S metallocluster. With both classes of the fusion proteins, cellular ET was enhanced by the ER antagonist 4-hydroxytamoxifen, albeit to different extents. In addition, one of Fds arising from ER-LBD insertion within the tetracysteine motif was found to acquire an oxygen-tolerant 2Fe-2S cluster, suggesting that ET is regulated through post-translational ligand binding. Furthermore, these findings show that domain insertion can be used to create protein electron carriers whose ET is regulated by environmental conditions. These metalloprotein switches are expected to be useful for achieving fast regulation of ET in engineered metabolic pathways and between electroactive bacteria and conductive materials.

36 MATERIALS SCIENCE↗

Comparison of Subdivided Versus Full-Length Fuel Pin Burnup in the ATF-2 Safety Analysis

The Accident Tolerant Fuels (ATF) campaign, under the Fuel Cycle Research and Development (FCRD) Advanced Fuels program, was developed after the Fukushima Daiichi Nuclear Power Plant disaster in 2011. Under ATF, fuel and cladding concepts are to be developed and tested that may more readily withstand an accident similar to the one that occurred at Fukushima Daiichi. ATF is a combination of industry, universities, and national laboratories in an effort to develop advanced accident tolerant cladding and fuel concepts. The end goal of the ATF program is to insert a lead test rod (LTR) or lead test assembly (LTA) into an operating commercial power light water reactor by 2022. In order to meet this 2022 insertion goal, ATF is split into three separate phases: ATF-1, ATF-2, and ATF-3. The first phase of the ATF program, ATF-1, is the concept feasibility study and early irradiation testing. Feasibility, fabrication, and out-of-pile testing are happening at universities and laboratories all over the United States. Irradiation testing of these concepts is happening at the Advanced Test Reactor (ATR) at the Idaho National Laboratory (INL). Early irradiation testing involves testing clad and/or fuel in drop-in capsules in the ATR. Currently, these capsules are in the relatively low-flux positions in the ATR, but some newer concepts and concepts that require higher burnup will be moved to the higher-flux positions later on during irradiation. Currently, Oak Ridge National Laboratory (ORNL), Westinghouse Electric Company, Areva, and General Electric (GE) have inserted capsules for ATF-1, although more concepts are planned. The second phase of ATF, ATF-2, is the focus of this paper. ATF-2 is the loop testing of fuel pins with new cladding and fuel concepts to simulate pressurized water reactor (PWR) and boiling water reactor (BWR) environments. ATF-2 will concurrently be happening at the ATR and at the Halden Reactor in Norway. The ATF-2 irradiation at the ATR will only simulate a PWR environment. ATF-2 will be inserted into the ATR pressurized water loop, Loop 2A, in the Center Flux Trap (CFT), where chemistry, temperature, and pressure can all be controlled separately from the primary coolant system and other loops in ATR. Loop 2A will be borated, pressurized to 2200 psi nominal, and have an average water temperature of 300 deg. C. A borated loop with fueled rodlets is extremely rare for Nuclear Energy experiments in the ATR, so ATF-2 will demonstrate new and unique capabilities for INL. ATF-3 is the testing of fresh and irradiated ATF concepts at the Transient Reactor Test (TREAT) Facility. The TREAT Reactor is planned for restart, re-establishing U.S. transient testing capabilities after nearly 20 years of non-operations. TREAT will test ATF concepts under transient conditions, such as a reactivity insertion accident. In addition to fresh fuel pins, TREAT will use from ATF2 and do transient testing on those irradiated pins. The information TREAT will provide to the vendors to support fuel licensing will be valuable, showing that these concepts do enhance the accident tolerance of the fuel in commercial reactors. (author)

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

A cellular selection identifies elongated flavodoxins that support electron transfer to sulfite reductase

Flavodoxins (Flds) mediate the flux of electrons between oxidoreductases in diverse metabolic pathways. To investigate whether Flds can support electron transfer to a sulfite reductase (SIR) that evolved to couple with a ferredoxin, we evaluated the ability of Flds to transfer electrons from a ferredoxin-NADP reductase (FNR) to a ferredoxin-dependent SIR using growth complementation of an Escherichia coli strain with a sulfur metabolism defect. We show that Flds from cyanobacteria complement this growth defect when coexpressed with an FNR and an SIR that evolved to couple with a plant ferredoxin. When we evaluated the effect of peptide insertion on Fld-mediated electron transfer, we observed a sensitivity to insertions within regions predicted to be proximal to the cofactor and partner binding sites, while a high insertion tolerance was detected within loops distal from the cofactor and within regions of helices and sheets that are proximal to those loops. Bioinformatic analysis showed that natural Fld sequence variability predicts a large fraction of the motifs that tolerate insertion of the octapeptide SGRPGSLS. In conclusion, these results represent the first evidence that Flds can support electron transfer to assimilatory SIRs, and they suggest that the pattern of insertion tolerance is influenced by interactions with oxidoreductase partners.

59 BASIC BIOLOGICAL SCIENCES↗

Cone-Beam Computed Tomography-Guided Percutaneous Radiologic Gastrostomy

The purpose of this study was to investigate the feasibility of a flat-detector C-arm-guided radiographic technique (cone-beam computed tomography [CBCT]) for percutaneous radiologic gastrostomy (PRG) insertion. Eighteen patients (13 men and 5 women; mean age 62 years) in whom percutaneous endoscopic gastrostomy (PEG) had failed underwent CBCT-guided PRG insertion. PEG failure or unsuitability was caused by upper gastrointestinal tract obstruction in all cases. Indications for gastrostomy were esophageal and head and neck malignancies, respectively. Before the PRG procedure, initial C-arm CBCT scans were acquired. Three- and 2-dimensional soft-tissue reconstructions of the epigastrium region were generated on a dedicated workstation. Subsequently, gastropexy was performed with T-fasteners after CBCT-guided puncture of the stomach bubble, followed by insertion of an 14F balloon-retained catheter through a peel-away introducer. Puncture of the stomach bubble and PRG insertion was technically successful in all patients without alteration of the epigastric region. There was no malpositioning of the tube or other major periprocedural complications. In 2 patients, minor complications occurred during the first 30 days of follow-up (PRG malfunction: n = 1; slight infection: n = 1). Late complications, which were mainly tube disturbances, were observed in 2 patients. The mean follow-up time was 212 days. CBCT-guided PRG is a safe, well-tolerated, and successful method of gastrostomy insertion in patients in whom endoscopic gastrostomy is not feasible. CBCT provides detailed imaging of the soft tissue and surrounding structures of the epigastric region in one diagnostic tour and thus significantly improves the planning of PRG procedures.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

CIRSE Standards of Practice Guidelines on Gastrostomy

PurposeSurgical Gastrostomy has been around since the 19th century but in 1980 the first successful percutaneous endoscopic gastrostomy was reported. A year later the first successful percutaneous gastrostomy was performed using fluoroscopic guidance. The technique for percutaneous insertion and the equipment used has been refined since then and it is now considered the gold standard for gastrostomy insertion. Here we present guidelines for image-guided enteral feeding tubes in adults.Material and MethodWe performed a review and analysis of the scientific literature, other national and international guidelines and expert opinion.ResultsStudies have shown fluoroscopic techniques have consistently higher success rates with lower rates of major complications than endoscopic techniques. However, the Achilles' heel of many fluoroscopic techniques is the requirement for smaller gastrostomy tube sizes resulting in them being more prone to blockages and thus requiring further intervention.ConclusionRadiological feeding tube insertion is a safe and effective procedure. Success rates are higher, and complication rates lower than PEG or surgical gastrostomy tube placement and innovative techniques for gastric and jejunal access mean that there are very few cases in which RIG is not possible. The principal weakness of radiologically inserted gastrostomies is the limitiation on tube size which leads to a higher rate of tube blockage. Per-oral image-guided gastrostomies have to an extent addressed this but have not been popularised. Currently many centres still consider endoscopic gastrostomies as the first line unless patients are too unwell to undergo this procedure or previous attempts have failed, in which case radioloically inserted gastrostomies are the technique of choice.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

The importance of the membrane interface as the reference state for membrane protein stability

The insertion of nascent polypeptide chains into lipid bilayer membranes and the stability of membrane proteins crucially depend on the equilibrium partitioning of polypeptides. For this, the transfer of full sequences of amino-acid residues into the bilayer, rather than individual amino acids, must be understood. Earlier studies have revealed that the most likely reference state for partitioning very hydrophobic sequences is the membrane interface. We have used μs-scale simulations to calculate the interface-to-transmembrane partitioning free energies ΔG S→TM for two hydrophobic carrier sequences in order to estimate the insertion free energy for all 20 amino acid residues when bonded to the center of a partitioning hydrophobic peptide. Our findings reflect that prior single-residue scales likely overestimate the partitioning free energies of polypeptides. The correlation of ΔG S→TM with experimental full-peptide translocon insertion data is high, implying an important role for the membrane interface in translocon-based insertion. The choice of carrier sequence greatly modulates the contribution of each single-residue mutation to the overall partitioning free energy. Our results demonstrate the importance of quantifying the observed full-peptide partitioning equilibrium, which is between membrane interface and transmembrane inserted, rather than combining individual water-to-membrane amino acid transfer free energies.

59 BASIC BIOLOGICAL SCIENCES↗

Heat transfer and pressure drop studies in a circular tube fitted with straight full twist

Experimental investigation of heat transfer characteristics of circular tube fitted with straight full twist insert has been presented. The heat transfer coefficient increases with Reynolds number and decreasing spacer distance with maximum being 2 in. spacer distance for both the type of twist inserts. Also, there is no appreciable increase in heat transfer enhancement in straight full twist insert with 2 in. spacer distance. Experiments were carried out in turbulent flow using straight full twist insert with 4 in. spacer and similar trend of increasing Nusselt number with Reynolds number was observed. Performance evaluation analysis was made and the maximum performance ratio was obtained for each twist insert corresponding to the Reynolds number of 2550. (author)

42 ENGINEERING↗

Structural characterization of C-S-H and C-A-S-H samples-Part II: Local environment investigated by spectroscopic analyses

Spectroscopic studies ({sup 1}H, {sup 23}Na and {sup 27}Al MAS NMR and Raman spectroscopy) have been used to characterize three series of C-S-H samples (0.8<Ca/Si<1.7): one C-S-H series, one aluminum inserted C-S-H series (named C-A-S-H series), and one sodium and aluminum inserted C-S-H series (named C-N-A-S-H series). Previous Rietveld analyses have been performed on the two first series and have clearly shown that (1) a unique 'tobermorite M defect' structural model allows to describe the C-S-H structure whatever the Ca/Si ratio and (2) the insertion of aluminum into the C-S-H structure led to the degradation of the crystallinity and to a systematic increase of the basal spacing of about 2 A regardless the Ca/(Si+Al) ratio (at a constant Al/Si ratio of 0.1). Spectroscopic investigations indicate that the main part of the Al atoms is readily incorporated into the interlayer region of the C-S-H structure. Al atoms are mainly inserted as four-fold coordinated aluminates in the dreierketten silicate chain (either in bridging or paired tetrahedra) at low Ca/Si ratio. Four-fold aluminates are progressively replaced by six-fold coordinated aluminates located into the interlayer region of the C-S-H structure and bonded to silicate chains. Investigation of the hydrogen bonding in C-S-H indicates that the main part of the hydrogen bonds is intra-main layer, and thus explains the low stacking cohesion of the C-S-H structure leading to its nanometric crystal size and the OD character of the tobermorite like structures. - Graphical abstract: The insertion of aluminum atoms into the C-S-H structure has been investigated by spectroscopic analyses ({sup 27}Al and {sup 1}H MAS NMR and Raman). The previously determined structural continuity, when increasing the C/S ratio from the C-S-H(I) type to the C-S-H(II) type, has been confirmed even in the presence of aluminum.

77 NANOSCIENCE AND NANOTECHNOLOGY↗