Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “imaging systems”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 847 records · Page 47

Optical-mechanical line-scan imaging process - Its information capacity and efficiency

Optical-mechanical line-scan techniques have been applied to earth satellite multispectral imaging systems. The capability of the imaging system is generally assessed by its information capacity. An approach based on information theory is developed to formulate the capacity of the line-scan process. Included are the effects of blurring of spatial detail, photosensor noise, aliasing, and quantization. The information efficiency is shown to be dependent on sampling rate, system frequency response shape, SNR, and quantization interval.

Huck, F. O.↗

Image-plane processing of visual information

Shannon's theory of information is used to optimize the optical design of sensor-array imaging systems which use neighborhood image-plane signal processing for enhancing edges and compressing dynamic range during image formation. The resultant edge-enhancement, or band-pass-filter, response is found to be very similar to that of human vision. Comparisons of traits in human vision with results from information theory suggest that: (1) Image-plane processing, like preprocessing in human vision, can improve visual information acquisition for pattern recognition when resolving power, sensitivity, and dynamic range are constrained. Improvements include reduced sensitivity to changes in lighter levels, reduced signal dynamic range, reduced data transmission and processing, and reduced aliasing and photosensor noise degradation. (2) Information content can be an appropriate figure of merit for optimizing the optical design of imaging systems when visual information is acquired for pattern recognition. The design trade-offs involve spatial response, sensitivity, and sampling interval.

Huck, F. O.↗

An image-guidance system for dynamic dose calculation in prostate brachytherapy using ultrasound and fluoroscopy

Purpose: Brachytherapy is a standard option of care for prostate cancer patients but may be improved by dynamic dose calculation based on localized seed positions. The American Brachytherapy Society states that the major current limitation of intraoperative treatment planning is the inability to localize the seeds in relation to the prostate. An image-guidance system was therefore developed to localize seeds for dynamic dose calculation. Methods: The proposed system is based on transrectal ultrasound (TRUS) and mobile C-arm fluoroscopy, while using a simple fiducial with seed-like markers to compute pose from the nonencoded C-arm. Three or more fluoroscopic images and an ultrasound volume are acquired and processed by a pipeline of algorithms: (1) seed segmentation, (2) fiducial detection with pose estimation, (3) seed matching with reconstruction, and (4) fluoroscopy-to-TRUS registration. Results: The system was evaluated on ten phantom cases, resulting in an overall mean error of 1.3 mm. The system was also tested on 37 patients and each algorithm was evaluated. Seed segmentation resulted in a 1% false negative rate and 2% false positive rate. Fiducial detection with pose estimation resulted in a 98% detection rate. Seed matching with reconstruction had a mean error of 0.4 mm. Fluoroscopy-to-TRUS registration had a mean error of 1.3 mm. Moreover, a comparison of dose calculations between the authors’ intraoperative method and an independent postoperative method shows a small difference of 7% and 2% forD{sub 90} and V{sub 100}, respectively. Finally, the system demonstrated the ability to detect cold spots and required a total processing time of approximately 1 min. Conclusions: The proposed image-guidance system is the first practical approach to dynamic dose calculation, outperforming earlier solutions in terms of robustness, ease of use, and functional completeness.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Ultrasound guided fluorescence molecular tomography with improved quantification by an attenuation compensated born-normalization and in vivo preclinical study of cancer

Ultrasound imaging, having the advantages of low-cost and non-invasiveness over MRI and X-ray CT, was reported by several studies as an adequate complement to fluorescence molecular tomography with the perspective of improving localization and quantification of fluorescent molecular targets in vivo. Based on the previous work, an improved dual-modality Fluorescence-Ultrasound imaging system was developed and then validated in imaging study with preclinical tumor model. Ultrasound imaging and a profilometer were used to obtain the anatomical prior information and 3D surface, separately, to precisely extract the tissue boundary on both sides of sample in order to achieve improved fluorescence reconstruction. Furthermore, a pattern-based fluorescence reconstruction on the detection side was incorporated to enable dimensional reduction of the dataset while keeping the useful information for reconstruction. Due to its putative role in the current imaging geometry and the chosen reconstruction technique, we developed an attenuation compensated Born-normalization method to reduce the attenuation effects and cancel off experimental factors when collecting quantitative fluorescence datasets over large area. Results of both simulation and phantom study demonstrated that fluorescent targets could be recovered accurately and quantitatively using this reconstruction mechanism. Finally, in vivo experiment confirms that the imaging system associated with the proposed image reconstruction approach was able to extract both functional and anatomical information, thereby improving quantification and localization of molecular targets.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Combining visible shadowgraph imaging with x-ray imaging for dynamic shock experiments

Interrogating ejecta particles launched from target materials that are undergoing dynamic shock can be done with both x-ray imaging and visible shadowgraph imaging. Our dynamic testing must be done inside a containment vessel with limited access ports available. We designed an imaging system to relay both types of imaging systems through a single port using the same optical relay and then splitting the images onto three separate high-speed imaging cameras outside the containment vessel. X-ray imaging provides ejecta density measurements. Shadowgraph imaging that is done at two wavelengths (blue and red) constrains ejecta particle size distributions and provides areal density measurements of the ejecta cloud. The ejecta particles are positioned 225 mm before the x-ray scintillators; this arrangement permits a folded mirror system to allow the shadowgraph data to bypass the x-ray scintillators. This configuration results in spatial separations between the intermediate image planes of the x-ray and shadowgraph images along the optical axis. At the position of the x-ray intermediate image plane, mirrors are positioned such that the shadowgraph images are kicked out and their images are sent on to different cameras. Positioning of the large doublet relay lenses keeps shrapnel from impacting the vessel containment windows.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Integrated imaging assembly and method for using

Certain disclosed embodiments concern an integrated imaging system that combined light-sheet microscopy, which enables considerable speed and phototoxicity gains, with quantitative-phase imaging. A method for using such imaging systems also is disclosed. In an exemplary embodiment, an integrated imaging system was used for multivariate investigation of live-cells in microfluidics.

Vasdekis, Andreas E.↗

Sparse sampling and reconstruction for electron and scanning probe microscope imaging

Systems and methods for conducting electron or scanning probe microscopy are provided herein. In a general embodiment, the systems and methods for conducting electron or scanning probe microscopy with an undersampled data set include: driving an electron beam or probe to scan across a sample and visit a subset of pixel locations of the sample that are randomly or pseudo-randomly designated; determining actual pixel locations on the sample that are visited by the electron beam or probe; and processing data collected by detectors from the visits of the electron beam or probe at the actual pixel locations and recovering a reconstructed image of the sample.

74 ATOMIC AND MOLECULAR PHYSICS↗

Three-dimensional broadband nonlinear phased array imaging

System include an ultrasonic transducer configured to couple to a nondestructive testing (NDT) sample and configured to produce and direct an ultrasonic probe wave at a selected frequency into a subsurface region of the NDT sample, a 3D laser scanning vibrometer configured to direct a detection beam in a scan area on a surface of the NDT sample and to receive a return beam from the scan area, and to detect, based on the return beam, a 3D motion of the surface across a wideband frequency range, and a processor, and a memory configured with instructions that, when executed by the processor, cause the processor to produce sub-surface image data of the NDT sample at multiple harmonics of the selected frequency in the wideband frequency range based on the detected 3D surface motion, wherein the sub-surface image data describes a nonlinear defect response produced in the NDT sample by interaction of the ultrasonic probe wave with the subsurface region.

Remillieux, Marcel↗

Thematic Mapper Image Processing System - Geometric correction performance for Landsat-5

Geometric correction performance data are presented for the Landsat-5 Thematic Mapper and the Thematic Mapper Image Processing System. Temporal registration and geodetic rectification results are displayed in the form of 90 percent errors. Both error estimation and direct measurements demonstrate that the instrument and system meet performance requirements.

Brooks, J.↗

VICAR image processing system guide to system use

The functional characteristics and operating requirements of the VICAR (Video Image Communication and Retrieval) system are described. An introduction to the system describes the functional characteristics and the basic theory of operation. A brief description of the data flow as well as tape and disk formats is also presented. A formal presentation of the control statement formats is given along with a guide to usage of the system. The guide provides a step-by-step reference to the creation of a VICAR control card deck. Simple examples are employed to illustrate the various options and the system response thereto.

Seidman, J. B.↗

Feature-space assessment of electrical impedance tomography coregistered with computed tomography in detecting multiple contrast targets

Purpose: Fusion of electrical impedance tomography (EIT) with computed tomography (CT) can be useful as a clinical tool for providing additional physiological information about tissues, but requires suitable fusion algorithms and validation procedures. This work explores the feasibility of fusing EIT and CT images using an algorithm for coregistration. The imaging performance is validated through feature space assessment on phantom contrast targets. Methods: EIT data were acquired by scanning a phantom using a circuit, configured for injecting current through 16 electrodes, placed around the phantom. A conductivity image of the phantom was obtained from the data using electrical impedance and diffuse optical tomography reconstruction software (EIDORS). A CT image of the phantom was also acquired. The EIT and CT images were fused using a region of interest (ROI) coregistration fusion algorithm. Phantom imaging experiments were carried out on objects of different contrasts, sizes, and positions. The conductive medium of the phantoms was made of a tissue-mimicking bolus material that is routinely used in clinical radiation therapy settings. To validate the imaging performance in detecting different contrasts, the ROI of the phantom was filled with distilled water and normal saline. Spatially separated cylindrical objects of different sizes were used for validating the imaging performance in multiple target detection. Analyses of the CT, EIT and the EIT/CT phantom images were carried out based on the variations of contrast, correlation, energy, and homogeneity, using a gray level co-occurrence matrix (GLCM). A reference image of the phantom was simulated using EIDORS, and the performances of the CT and EIT imaging systems were evaluated and compared against the performance of the EIT/CT system using various feature metrics, detectability, and structural similarity index measures. Results: In detecting distilled and normal saline water in bolus medium, EIT as a stand-alone imaging system showed contrast discrimination of 47%, while the CT imaging system showed a discrimination of only 1.5%. The structural similarity index measure showed a drop of 24% with EIT imaging compared to CT imaging. The average detectability measure for CT imaging was found to be 2.375 ± 0.19 before fusion. After complementing with EIT information, the detectability measure increased to 11.06 ± 2.04. Based on the feature metrics, the functional imaging quality of CT and EIT were found to be 2.29% and 86%, respectively, before fusion. Structural imaging quality was found to be 66% for CT and 16% for EIT. After fusion, functional imaging quality improved in CT imaging from 2.29% to 42% and the structural imaging quality of EIT imaging changed from 16% to 66%. The improvement in image quality was also observed in detecting objects of different sizes. Conclusions: The authors found a significant improvement in the contrast detectability performance of CT imaging when complemented with functional imaging information from EIT. Along with the feature assessment metrics, the concept of complementing CT with EIT imaging can lead to an EIT/CT imaging modality which might fully utilize the functional imaging abilities of EIT imaging, thereby enhancing the quality of care in the areas of cancer diagnosis and radiotherapy treatment planning.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Quantitative metrics for assessment of chemical image quality and spatial resolution

Rationale: Currently objective/quantitative descriptions of the quality and spatial resolution of mass spectrometry derived chemical images are not standardized. Development of these standardized metrics is required to objectively describe chemical imaging capabilities of existing and/or new mass spectrometry imaging technologies. Such metrics would allow unbiased judgment of intra-laboratory advancement and/or inter-laboratory comparison for these technologies if used together with standardized surfaces. Methods: We developed two image metrics, viz., chemical image contrast (ChemIC) based on signal-to-noise related statistical measures on chemical image pixels and corrected resolving power factor (cRPF) constructed from statistical analysis of mass-to-charge chronograms across features of interest in an image. These metrics, quantifying chemical image quality and spatial resolution, respectively, were used to evaluate chemical images of a model photoresist patterned surface collected using a laser ablation/liquid vortex capture mass spectrometry imaging system under different instrument operational parameters. Results: The calculated ChemIC and cRPF metrics determined in an unbiased fashion the relative ranking of chemical image quality obtained with the laser ablation/liquid vortex capture mass spectrometry imaging system. These rankings were used to show that both chemical image contrast and spatial resolution deteriorated with increasing surface scan speed, increased lane spacing and decreasing size of surface features. Conclusions: ChemIC and cRPF, respectively, were developed and successfully applied for the objective description of chemical image quality and spatial resolution of chemical images collected from model surfaces using a laser ablation/liquid vortex capture mass spectrometry imaging system.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Sparsity-based acoustic inversion in cross-sectional multiscale optoacoustic imaging

Purpose: With recent advancement in hardware of optoacoustic imaging systems, highly detailed cross-sectional images may be acquired at a single laser shot, thus eliminating motion artifacts. Nonetheless, other sources of artifacts remain due to signal distortion or out-of-plane signals. The purpose of image reconstruction algorithms is to obtain the most accurate images from noisy, distorted projection data. Methods: In this paper, the authors use the model-based approach for acoustic inversion, combined with a sparsity-based inversion procedure. Specifically, a cost function is used that includes the L1 norm of the image in sparse representation and a total variation (TV) term. The optimization problem is solved by a numerically efficient implementation of a nonlinear gradient descent algorithm. TV–L1 model-based inversion is tested in the cross section geometry for numerically generated data as well as for in vivo experimental data from an adult mouse. Results: In all cases, model-based TV–L1 inversion showed a better performance over the conventional Tikhonov regularization, TV inversion, and L1 inversion. In the numerical examples, the images reconstructed with TV–L1 inversion were quantitatively more similar to the originating images. In the experimental examples, TV–L1 inversion yielded sharper images and weaker streak artifact. Conclusions: The results herein show that TV–L1 inversion is capable of improving the quality of highly detailed, multiscale optoacoustic images obtained in vivo using cross-sectional imaging systems. As a result of its high fidelity, model-based TV–L1 inversion may be considered as the new standard for image reconstruction in cross-sectional imaging.

60 APPLIED LIFE SCIENCES↗

System and method for testing true stress and true strain

A true stress testing system broadly comprising a force input machine, an imaging system, and a computer. The imaging system includes a light source for projecting a light beam at the specimen in a first direction and a camera positioned on an opposite side of the specimen for receiving portions of the light beam not blocked by the specimen such that a shadow image of the specimen is created via the camera. The computer may determine a minimum dimension of the specimen perpendicular to the first direction at a point in time over a plurality of points along the force axis via the shadow image of the specimen such that the processor accounts for changes in position of the minimum dimension along the specimen. A true stress of the specimen may then be determined according to the minimum dimension of the specimen perpendicular to the first direction at the point in time.

42 ENGINEERING↗

Evaluation of visual acuity with Gen 3 night vision goggles

Using laboratory simulations, visual performance was measured at luminance and night vision imaging system (NVIS) radiance levels typically encountered in the natural nocturnal environment. Comparisons were made between visual performance with unaided vision and that observed with subjects using image intensification. An Amplified Night Vision Imaging System (ANVIS6) binocular image intensifier was used. Light levels available in the experiments (using video display technology and filters) were matched to those of reflecting objects illuminated by representative night-sky conditions (e.g., full moon, starlight). Results show that as expected, the precipitous decline in foveal acuity experienced with decreasing mesopic luminance levels is effectively shifted to much lower light levels by use of an image intensification system. The benefits of intensification are most pronounced foveally, but still observable at 20 deg eccentricity. Binocularity provides a small improvement in visual acuity under both intensified and unintensified conditions.

Bradley, Arthur↗

Estimation of radiative properties and temperature distributions in coal-fired boiler furnaces by a portable image processing system

This paper presented an experimental investigation on the estimation of radiative properties and temperature distributions in a 670 t/h coal-fired boiler furnace by a portable imaging processing system. The portable system has been calibrated by a blackbody furnace. Flame temperatures and emissivities were measured by the portable system and equivalent blackbody temperatures were deduced. Comparing the equivalent blackbody temperatures measured by the portable system and the infrared pyrometer, the relative difference is less than 4%. The reconstructed pseudo-instantaneous 2-D temperature distributions in two cross-sections can disclose the combustion status inside the furnace. The measured radiative properties of particles in the furnace proved there is significant scattering in coal-fired boiler furnaces and it can provide useful information for the calculation of radiative heat transfer and numerical simulation of combustion in coal-fired boiler furnaces. The preliminary experimental results show this technology will be helpful for the combustion diagnosis in coal-fired boiler furnaces. (author)

01 COAL, LIGNITE, AND PEAT↗

Decommissioning Characterisation Through Compressive Gamma-Ray Imaging - 19308

We present the imaging results from two novel single pixel gamma-ray imaging systems, developed at ANSTO, in order to support the characterisation phase of decommissioning activities. The ability to remotely locate, identify, and quantify gamma emitting radionuclides can provide crucial information for the development of an efficient decommissioning plan. The imaging systems have been designed around the theory of compressed sensing and make use of a single spectroscopic detector and a set of dual, rotating, nested tungsten masks. The imaging system designs provide a large field of view and cover an energy range of 40 keV to 1.5 MeV. The first system has been specifically developed to image the High Flux Australian Reactor (HIFAR) reactor vessel with a hemispherical 2π field of view and provided quantitative information on the location of the gamma-ray emitting radionuclides present, whilst operating in a ∼10 Sv/h dose rate environment. The second system is a portable, high sensitivity imager with a cylindrical 360 deg. x 90 deg. field of view used for localising and identifying low to medium dose rate sources in the remaining facility infrastructure. Gamma-ray images were then accurately overlaid on optical images to allow for easy visualisation of the location of gamma emitting radionuclides. The spectroscopic gamma-ray imaging of point sources has been demonstrated with only 1/10. of the measurements normally required by traditional aperture based imaging techniques. The compressive gamma-ray imaging technique provides a novel and highly configurable spectroscopic imaging capability for applications in the nuclear industry. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗