Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “imaging instruments”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 847 records · Page 47

Achromatic Emission Velocity Measurements in Luminous Flows

A new velocity measurement instrument for luminous flows was developed by Science Research Laboratory for NASA. The SIEVE (Segmented Image Emission VElocimeter) instrument uses broadband light emitted by the flow for the velocity measurement. This differs from other velocimetry techniques in that it does not depend on laser illumination and/or light scattering from particles in the flow. The SIEVE is a passive, non-intrusive diagnostic. By moving and adjusting the imaging optics, the SIEVE can provide three-dimensional mapping of a flow field and determine turbulence scale size. A SIEVE instrument was demonstrated on an illuminated rotating disk to evaluate instrument response and noise and on an oxy-acetylene torch to measure flame velocities. The luminous flow in rocket combustors and plumes is an ideal subject for the SIEVE velocity measurement technique.

Schneider, S. J.↗

Wavelength tunable liquid crystal imaging filters for remote sensing from geosynchronous platforms

Recent advances in liquid crystal technology have enabled us to construct tunable birefringent filters with bandwidths between approximately 0.1 nm and 50 nm. The center wavelength of these filters can be selected electronically, in a few tens of milliseconds, with no moving parts. These liquid crystal tunable filters (LCTF's), together with existing CCD detectors, make possible a new generation of lightweight, rugged, high-resolution imaging spectrophotometers. Such instruments would be particularly interesting for remote sensing applications from geosynchronous platforms. Important advantages exist in the aperture, absence of image shift, power consumption, size, weight, and absence of high drive frequencies, compared to current instruments used or considered for multispectral scene analysis. In the present work, we have reviewed spectral requirements of planned NASA geosynchronous remote sensing missions and identified several applications of the liquid crystal tunable filter technology. We have modeled the LCTF performance in the visible and near-infrared, and carried out a literature study on space-hardening of the filter components, to evaluate the suitability of LCTF's for geosynchronous missions. We have also compared the power consumption, weight, size, reliability, and optical performance of an imaging spectrophotometer using a LCTF monochromator, to other instruments that have been put forward for remote sensing from geosynchronous platforms. We put forward some conceptual designs for LCTF's that seem to offer important reliability, over the mechanical filter wheels presently baselined for the HEPI and ALM experiments. The extremely wide acceptance angle achievable with LCTF's could also avoid the present need for large-aperture interference filters in the ALM (and LIS) experiments. Thermal vacuum testing and radiation damage analysis is required to investigate the space hardening of these new filters for geosynchronous flight.

Foukal, Peter↗

Medical Radiation Dosimetry: Concepts and Needs

Radiation is used widely used in medicine for diagnostic and therapeutic applications. Both the desired effects and the potential detrimental side effects depend on the radiation dose delivered. As such it is essential to determining the radiation dose received by patients as accurately as needed to optimise the radiation procedure. Solid state dosimeters are increasingly used in medicine because of their small physical size, high sensitivity and usually low cost. Combining multiple detectors allows the detection of radiation dose distributions, an application where the distinction between radiation dosimeter and image detector starts to blur. Given the rapid development of detector technology it can be expected that the utilisation of solid-state dosimeters in medicine will continue to increase.

61 RADIATION PROTECTION AND DOSIMETRY↗

DETECTABILITY OF EXOPLANETS IN THE {beta} PIC MOVING GROUP WITH THE GEMINI PLANET IMAGER

We model the detectability of exoplanets around stars in the {beta} Pic Moving Group (BPMG) using the Gemini Planet Imager (GPI), a coronagraphic instrument designed to detect companions by imaging. Members of the BPMG are considered promising targets for exoplanet searches because of their youth ({approx}12 Myr) and proximity (median distance {approx}35 pc). We wrote a modeling procedure to generate hypothetical companions of given mass, age, eccentricity, and semi-major axis, and place them around BPMG members that fall within the V-band range of the GPI. We count companions lying within the GPI's field of view and H-band fluxes that have a host-companion flux ratio placing them within its sensitivity as possible detections. The fraction of companions that could be detected depends on their brightness at 12 Myr, and hence formation mechanism, and on their distribution of semi-major axes. We used brightness models for formation by disk instability and core-accretion. We considered the two extreme cases of the semi-major axis distribution-the log-normal distribution of the nearby F- and G-type stars and a power-law distribution indicated by the exoplanets detected by the radial velocity technique. We find that the GPI could detect exoplanets of all the F and G spectral type stars in the BPMG sample with a probability that depends on the brightness model and semi-major axis distribution. At spectral type K-M1, exoplanet detectability depends on brightness and hence distance of the host star. GPI will be able to detect the companions of M stars later than M1 only if they are closer than 10 pc. Of the four A stars in the BPMG sample, only one has a V-band brightness in the range of GPI; the others are too bright.

79 ASTRONOMY AND ASTROPHYSICS↗

Multimodal differential emission measure in the solar corona

The Atmospheric Imaging Assembly (AIA) telescope on board the Solar Dynamics Observatory provides coronal extreme ultraviolet imaging over a broader temperature sensitivity range than the previous generations of instruments (Extreme Ultraviolet Imager; EUVI, EIT, and TRACE). Differential emission measure tomography (DEMT) of the solar corona based on AIA data is presented here for the first time. The main product of DEMT is the three-dimensional distribution of the local differential emission measure (LDEM). While in previous studies, based on EIT or EUVI data, there were three available EUV bands, the present study is based on the four cooler AIA bands (aimed at studying the quiet sun). The AIA filters allow exploration of new parametric LDEM models. Since DEMT is better suited for lower activity periods, we use data from Carrington Rotation 2099, when the Sun was in its most quiescent state during the AIA mission. Also, we validate the parametric LDEM models by using them to perform a bi-dimensional differential emission measure (DEM) analysis on sets of simultaneous AIA images, and comparing results with those obtained using other methods. Our study reveals a ubiquitous bimodal LDEM distribution in the quiet diffuse corona, characterized by two well-defined average centroid temperatures 〈T{sub 0,1}〉=(1.47±0.05) MK and 〈T{sub 0,2}〉=(2.57±0.05) MK. We argue that the nanoflare heating scenario is less likely to explain these results, and that alternative mechanisms, such as wave dissipation, appear better supported by our results.

79 ASTRONOMY AND ASTROPHYSICS↗

Removal of instrument signature from Mariner 9 television images of Mars

The Mariner 9 spacecraft was inserted into orbit around Mars in November 1971. The two vidicon camera systems returned over 7300 digital images during orbital operations. The high volume of returned data and the scientific objectives of the Television Experiment made development of automated digital techniques for the removal of camera system-induced distortions from each returned image necessary. This paper describes the algorithms used to remove geometric and photometric distortions from the returned imagery. Enhancement processing of the final photographic products is also described.

Green, W. B.↗

A laboratory demonstration of high-resolution hard X-ray and gamma-ray imaging using Fourier-transform techniques

A laboratory imaging system has been developed to study the use of Fourier-transform techniques in high-resolution hard X-ray and gamma-ray imaging, with particular emphasis on possible applications to high-energy astronomy. Considerations for the design of a Fourier-transform imager and the instrumentation used in the laboratory studies is described. Several analysis methods for image reconstruction are discussed including the CLEAN algorithm and maximum entropy methods. Images obtained using these methods are presented.

Palmer, David↗

Current instrument status of the Airborne Visible/Infrared Imaging Spectrometer (AVIRIS)

An upgraded version of AVIRIS, an airborne imaging spectrometer based on a whiskbroom-type scanner coupled via optical fibers to four dispersive spectrometers, that has been in operation since 1987 is described. Emphasis is placed on specific AVIRIS subsystems including foreoptics, fiber optics, and an in-flight reference source; spectrometers and detector dewars; a scan drive mechanism; a signal chain; digital electronics; a tape recorder; calibration systems; and ground support requirements.

Eastwood, Michael L.↗

Dayside Aurora Dynamics

Images from the FUV (Far UltraViolet) instrument on board the IMAGE spacecraft will be presented to demonstrate the auroral dynamics in the dayside auroral zone and the polar cap region. optical emissions detected by three different detectors of FUV come from precipitations of energetic protons, electrons, and both species, respectively. In general, auroral activities in these regions responded very well to variations in the boundary conditions either external or internal to the magnetosphere, i.e., in the solar wind or the magnetotail. As a result, auroral images from FUV provide an excellent tool to investigate particle acceleration and transport processes within the geospace, such as shock acceleration, substorm injections, etc. we will interpret the observed auroral images using various models, discuss difference and similarity in the auroral activity from several typical cases, and assess conditions optimal to each type of auroral activity.

Spann, James F.↗

Uncertainty of Passive Imager Cloud Optical Property Retrievals to Instrument Radiometry and Model Assumptions: Examples from MODIS

The optical and microphysical structure of clouds is of fundamental importance for understanding a variety of cloud radiation and precipitation processes. With the advent of MODIS on the NASA EOS Terra and Aqua platforms, simultaneous global-daily 1 km retrievals of cloud optical thickness (COT) and effective particle radius (CER) are provided, as well as the derived water path (WP). The cloud product (MOD06/MYD06 for MODIS Terra and Aqua, respectively) provides separate retrieval datasets for various two-channel retrievals, typically a VISNIR channel paired with a 1.6, 2.1, and 3.7 m spectral channel. The MOD06 forward model is derived from on a homogeneous plane-parallel cloud. In Collection 5 processing (completed in 2007 with a modified Collection 5.1 completed in 2010), pixel-level retrieval uncertainties were calculated for the following non-3-D error sources: radiometry, surface spectral albedo, and atmospheric corrections associated with model analysis uncertainties (water vapor only). The latter error source includes error correlation across the retrieval spectral channels. Estimates of uncertainty in 1 aggregated (Level-3) means were also provided assuming unity correlation between error sources for all pixels in a grid for a single day, and zero correlation of error sources from one day to the next. I n Collection 6 (expected to begin in late summer 2013) we expanded the uncertainty analysis to include: (a) scene-dependent calibration uncertainty that depends on new band and detector-specific Level 1B uncertainties, (b) new model error sources derived from the look-up tables which includes sensitivities associated with wind direction over the ocean and uncertainties in liquid water and ice effective variance, (c) thermal emission uncertainties in the 3.7 m band associated with cloud and surface temperatures that are needed to extract reflected solar radiation from the total radiance signal, (d) uncertainty in the solar spectral irradiance at 3.7 m, and (e) addition of stratospheric ozone uncertainty in visible atmospheric corrections. A summary of the approach and example Collection 6 results will be shown.

Cloud Properties Observations↗

Using DSCOVR EPIC as a Transfer Radiometer to Scale Multiple VIIRS Sensors Over Tropical Earth Views

The NASA CERES project provides Energy Balanced and Filled (EBAF) product climate-quality observed TOA and computed surface fluxes to the climate community. The CERES instruments are on board the Terra, Aqua, Suomi-NPP, and NOAA-20 satellites. The CERES project radiometrically scales the MODIS and VIIRS imager visible channel radiances to the Aqua- MODIS reference to retrieve consistent imager cloud properties between sensors, which are used to retrieve cloud properties required for converting CERES radiance observations into fluxes. The NPP, NOAA-20, and the future NOAA-21 VIIRS imagers will be in the same sun- synchronous orbit but spaced equally apart, which means that no simultaneous nadir overpasses (SNO) may be used to inter-calibrate the VIIRS imagers to each one another. Currently, the CERES project uses Aqua-MODIS to radiometrically scale between VIIRS imagers. Once the Terra and Aqua satellites start drifting toward the terminator, Aqua-MODIS can no longer be utilized as the transfer radiometer between VIIRS sensors and there will be no SNOs in common between either MODIS and or VIIRS imagers. The DSCOVR satellite orbits the Lagrange-1 (L1) point about 1.5 million kilometers from Earth. The Earth Polychromatic Imaging Camera (EPIC) instrument on the Earth-facing side of DSCOVR takes images ranging from the UV to the NIR of the sunlit side of the Earth. While the EPIC sensor has no onboard calibration systems, multiple inter-calibration studies have indicated that the EPIC instrument response is radiometrically stable. The stability of the EPIC instrument allows it to be used as a transfer radiometer between all MODIS and VIIRS imagers and is especially suited for drifting orbits because EPIC imager frequently samples the Earth diurnally. The study will demonstrate the use of EPIC as a transfer radiometer to radiometrically scale the NPP and NOAA-20 VIIRS imagers. The scaling factors will be compared with the scaling factors using Aqua-MODIS as the transfer radiometer.

Conor Haney↗