Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “image simulation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 847 records · Page 47

Imaging the kinetics of anisotropic dissolution of bimetallic core–shell nanocubes using graphene liquid cells

Chemical design of multicomponent nanocrystals requires atomic-level understanding of reaction kinetics. Here, we apply single-particle imaging coupled with atomistic simulation to study reaction pathways and rates of Pd@Au and Cu@Au core-shell nanocubes undergoing oxidative dissolution. Quantitative analysis of etching kinetics using in situ transmission electron microscopy (TEM) imaging reveals that the dissolution mechanism changes from predominantly edge-selective to layer-by-layer removal of Au atoms as the reaction progresses. Dissolution of the Au shell slows down when both metals are exposed, which we attribute to galvanic corrosion protection. Morphological transformations are determined by intrinsic anisotropy due to coordination-number-dependent atom removal rates and extrinsic anisotropy induced by the graphene window. Our work demonstrates that bimetallic coreshell nanocrystals are excellent probes for the local physicochemical conditions inside TEM liquid cells. Furthermore, single-particle TEM imaging and atomistic simulation of reaction trajectories can inform future design strategies for compositionally and architecturally sophisticated nanocrystals.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Combined speckle- and propagation-based single shot two-dimensional phase retrieval method

Single-shot two-dimensional (2D) phase retrieval (PR) can recover the phase shift distribution within an object from a single 2D x-ray phase contrast image (XPCI). Two competing XPCI imaging modalities often used for single-shot 2D PR to recover material properties critical for predictive performance capabilities are: speckle-based (SP-XPCI) and propagation-based (PB-XPCI) XPCI imaging. However, PR from SP-XPCI and PB-XPCI images are, respectively, limited to reconstructing accurately slowly and rapidly varying features due to noise and differences in their contrast mechanisms. Herein, we consider a combined speckle- and propagation-based XPCI (SPB-XPCI) image by introducing a mask to generate a reference pattern and imaging in the near-to-holographic regime to induce intensity modulations in the image. We develop a single-shot 2D PR method for SPB-XPCI images of pure phase objects without imposing restrictions such as object support constraints. It is compared against PR methods inspired by those developed for SP-XPCI and PB-XPCI on simulated and experimental images of a thin glass shell before and during shockwave compression. Reconstructed phase maps show improvements in quantitative scores of root-mean-square error and structural similarity index measure using our proposed method.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

SU-F-J-196: A Prototype System for Portal Imaging for Intensity Modulated Neutron Therapy

Purpose: Fast neutron therapy is offered at the University of Washington Medical Center for treatment of selected cancers. The hardware and control systems of the UW Clinical Neutron Therapy System are undergoing upgrades to enable delivery of IMNT. To clinically implement IMNT, dose verification tools need to be developed. We propose a portal imaging system that relies on the creation of positron emitting isotopes ({sup 11}C and {sup 15}O) through (n, 2n) reactions with a PMMA plate placed below the patient. After field delivery, the plate is retrieved from the vault and imaged using a reader that detects the annihilation photons. The pattern of activity produced in the plate provides information to reconstruct the neutron fluence map that can be compared to fluence maps from Monte Carlo (MCNP) simulations to verify treatment delivery. We have previously performed Monte Carlo simulations of the portal imaging system (GATE simulations) and the beam line (MCNP simulations). In this work, initial measurements using a prototype system are presented. Methods: Custom electronics were developed for BGO detectors read out with photomultiplier tubes (previous generation PET detectors from a CTI ECAT 953 scanner). Two detectors were placed in coincidence, with a detector separation of 2 cm. Custom software was developed to create the crystal look up tables and perform a limited angle planar reconstruction with a stochastic normalization. To test the initial capabilities of the system, PMMA squares were irradiated with neutrons at a depth of 1.5 cm and read out using the prototype system. Doses ranging from 10–200 cGy were delivered. Results: Using the prototype system, dose differences in the therapeutic range could be determined. Conclusion: The prototype portal imaging system is capable of detecting neutron doses as low as 10–50 cGy and shows great promise as a patient QA tool for IMNT.

60 APPLIED LIFE SCIENCES↗

Comprehensive study of the interactions between the critical dimensionless numbers associated with multiphase flow in 3D porous media

Multiphase flow in porous media is of signifcant interest in many engineering applications, such as geologic carbon sequestration, enhanced oil recovery, and groundwater contamination and remediation. In order to advance the fundamental understanding of multiphase flow in complex three-dimensional (3D) porous media, the interactions between the critical dimensionless numbers, including the contact angle, viscosity ratio, and capillary (Ca) number, were explored using X-ray micro-computed tomography (micro-CT) scanning and lattice Boltzmann (LB) modeling. In this study, the 3D pore structure information was extracted from micro-CT images and then used as interior boundary conditions of flow modeling in a pore-scale LB simulator to simulate multiphase flow within the pore space. A Berea sandstone sample was scanned and then two-phase flow LB simulations were performed based on the micro-CT images. The LB-simulated water/CO 2 distributions agreed well with the micro-CT scanned images. Simulation findings showed that a decreasing contact angle causes a decrease in wetting-fluid relative permeability and an increase in non-wetting fluid relative permeability. A rising Ca number increases both wetting and non-wetting fluid relative permeabilities. An increasing viscosity ratio (the ratio of non-wetting fluid viscosity to wetting fluid viscosity) facilitates the increase of non-wetting fluid relative permeability and mitigates the reduction of wetting fluid relative permeability, when the contact angle decreases continuously. The primary novel finding of this study is that the viscosity ratio affects the rate of change of the relative permeability curves for both phases when the contact angle changes continuously. To date, we believe it is the first time that comprehensive interactions between these dimensionless numbers are demonstrated in a sandstone sample based on real 3D structures. We also investigated the role of the changes of flow direction and sample location on relative permeability curves. Simulation results showed that the change in non-wetting fluid relative permeability was larger when the flow direction was switched from vertical to horizontal, which indicated that there was stronger anisotropy in larger pore networks that were primarily occupied by the non-wetting fluid.

42 ENGINEERING↗

Transcranial phase aberration correction using beam simulations and MR-ARFI

Purpose: Transcranial magnetic resonance-guided focused ultrasound surgery is a noninvasive technique for causing selective tissue necrosis. Variations in density, thickness, and shape of the skull cause aberrations in the location and shape of the focal zone. In this paper, the authors propose a hybrid simulation-MR-ARFI technique to achieve aberration correction for transcranial MR-guided focused ultrasound surgery. The technique uses ultrasound beam propagation simulations with MR Acoustic Radiation Force Imaging (MR-ARFI) to correct skull-caused phase aberrations. Methods: Skull-based numerical aberrations were obtained from a MR-guided focused ultrasound patient treatment and were added to all elements of the InSightec conformal bone focused ultrasound surgery transducer during transmission. In the first experiment, the 1024 aberrations derived from a human skull were condensed into 16 aberrations by averaging over the transducer area of 64 elements. In the second experiment, all 1024 aberrations were applied to the transducer. The aberrated MR-ARFI images were used in the hybrid simulation-MR-ARFI technique to find 16 estimated aberrations. These estimated aberrations were subtracted from the original aberrations to result in the corrected images. Each aberration experiment (16-aberration and 1024-aberration) was repeated three times. Results: The corrected MR-ARFI image was compared to the aberrated image and the ideal image (image with zero aberrations) for each experiment. The hybrid simulation-MR-ARFI technique resulted in an average increase in focal MR-ARFI phase of 44% for the 16-aberration case and 52% for the 1024-aberration case, and recovered 83% and 39% of the ideal MR-ARFI phase for the 16-aberrations and 1024-aberration case, respectively. Conclusions: Using one MR-ARFI image and noa priori information about the applied phase aberrations, the hybrid simulation-MR-ARFI technique improved the maximum MR-ARFI phase of the beam's focus.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-F-J-116: Clinical Experience-Based Verification and Improvement of a 4DCT Program

Purpose: To demonstrate the role of continuous improvement fulfilled by the Medical Physicist in clinical 4DCT and CBCT scanning. Methods: Lung (SABR and Standard) patients’ 4D respiratory motion and image data were reviewed over a 3, 6 and 12 month period following commissioning testing. By identifying trends of clinically relevant parameters and respiratory motions, variables were tested with a programmable motion phantom and assessed. Patient traces were imported to a motion phantom and 4DCT and CBCT imaging were performed. Cos6 surrogate and sup-inf motion was also programmed into the phantom to simulate the long exhale of patients for image contrast tests. Results: Patient surrogate motion amplitudes were 9.9+5.2mm (3–35) at 18+6bpm (6–30). Expiration/Inspiration time ratios of 1.4+0.5second (0.6–2.9) showed image contrast effects evident in the AveCT and 3DCBCT images. Small differences were found for patients with multiple 4DCT data sets. Patient motion assessments were simulated and verified with the phantom within 2mm. Initial image reviews to check for reconstructed artefacts and data loss identified a small number of patients with irregularities in the automatic placement of inspiration and expiration points. Conclusion: The Physicist’s involvement in the continuous improvements of a clinically commissioned technique, processes and workflows continues beyond the commissioning stage of a project. Our experience with our clinical 4DCT program shows that Physics presence is required at the clinical 4DCT scan to assist with technical aspects of the scan and also for clinical image quality assessment prior to voluming. The results of this work enabled the sharing of information from the Medical Physics group with the Radiation Oncologists and Radiation Therapists. This results in an improved awareness of clinical patient respiration variables and how they may affect 4D simulation images and also may also affect the treatment verification images.

60 APPLIED LIFE SCIENCES↗

SU-F-J-62: Assessment of Dose Changes Due to Anterior-Posterior Patient Separation During Daily MVCT Scans

Purpose: To determine the effects of patient separation on absolute dose and dose distribution in patients undergoing pelvic radiotherapy on TomoTherapy. Methods: An Alderson RANDO phantom with 4cm of bolus was imaged on a CT simulator and the resulting scans were contoured as a whole pelvic case. Using TomoTherapy Planning Station, the plan was designed to give 45 Gy to 95% of the treatment volume in 25 fractions. TomoTherapy MVCT scans were performed on the RANDO phantom with 2cm and 4cm of bolus removed to simulate visible changes in a patient’s anatomy. The MVCT images were rigidly registered with planning CT images on TomoTherapy Planned Adaptive. The original fluence was recalculated on the MVCT images and changes in dose distribution due to patient separation were quantified by the changes in DVHs for the target volume and the organs at risk. Results: Patient separation difference equivalent to 2cm and 4cm in anterior-posterior direction resulted in an increase of the PTV D50 and maximum PTV dose of 5.6%, 6.2% for 2cm and 7.7%, 10.4% for 4cm, respectively. For the 2cm change, D50 and maximum doses to organs at risk increased by 6.5%, 7.1% in the bladder, 4.9%, 4.8% in the rectum, and 5.3%, 6.6% in the bowel. For the 4cm change, D50 and maximum doses increased by 10.7%, 12.2% in the bladder, 5.9%, 6.1% in the rectum, and 7.7%, 10.1% in the bowel. Conclusion: This research indicates that, without any changes to the structures, patient separation in the anterior-posterior direction can affect the dose distribution for the PTV and organs at risk. These results can assist physicians in determining if obtaining a new CT simulation set and replanning is necessary for pelvic patients on TomoTherapy.

60 APPLIED LIFE SCIENCES↗

Application of the TITAN Hybrid Deterministic Transport Code to Medical Physics - Paper 118

The TITAN code is a 3-dimensional parallel deterministic transport code that solves the linear Boltzmann equation. The TITAN code has hybrid algorithms that are ideal for medical physics applications: i) SN and characteristics method and ii) SN with a fictitious quadrature set and ray-tracing. These hybrid algorithms have been used in the simulation of computed tomography (CT) and single photon emission computed tomography (SPECT) In this paper, the hybrid algorithms developed for medical physics applications in the TITAN code are discussed. First, the TITAN code's block-oriented approach for utilizing SN and characteristic solvers for CT is presented and results for a simple test case are given. Second, the paper describes a hybrid formulation for SPECT with an SN solver in the phantom, a fictitious quadrature set for directions from the phantom surface passing through the collimator, and a simplified ray-tracing algorithm for particle transport to the detector. Finally, ongoing work is described and concluding remarks are given. The TITAN code's hybrid algorithms allow it to efficiently solve problems with low-scatter regions, which are frequently found in medical physics applications. The TITAN code has been used to solve a simplified CT problem and generate projection images for SPECT simulations. The WCOS technique was developed to improve the TITAN code's collimator representation. For these applications, the TITAN code was shown to require significantly less computation time than MCNP5. Work is currently underway to implement an iterative image reconstruction algorithm in the TITAN code. A script that calls the TITAN code to complete the forward projection step in SPECT has already been used to reconstruction a 2-dimensional phantom. The ability of TITAN to fully model particle transport in the patient in short computation times is expected to be a great advantage to iterative reconstruction. (authors)

61 RADIATION PROTECTION AND DOSIMETRY↗

An online x-ray based position validation system for prostate hypofractionated radiotherapy

Purpose: Accurate positioning of the target volume during treatment is paramount for stereotactic body radiation therapy (SBRT). In this work, the authors present the development of an in-house software tool to verify target position with an Elekta-Synergy linear accelerator using kV planar images acquired during treatment delivery. Methods: In-house software, SeedTracker, was developed in MATLAB to perform the following three functions: 1. predict intended seed positions in a planar view perpendicular to any gantry angle, simulating a portal imaging device, from the 3D seed co-ordinates derived from the treatment planning system; 2. autosegment seed positions in kV planar images; and 3. report the position shift based on the seed positions in the projection images. The performance of SeedTracker was verified using a CIRS humanoid phantom (CIRS, VA, USA) implanted with three Civco gold seed markers (Civco, IA, USA) in the prostate. The true positive rate of autosegmentation (TPR{sub seg}) and the accuracy of the software in alerting the user when the isocenter position was outside the tolerance (TPR{sub trig}) were studied. Two-dimensional and 3D static position offsets introduced to the humanoid phantom and 3D dynamic offsets introduced to a gel phantom containing gold seeds were used for evaluation of the system. Results: SeedTracker showed a TPR{sub seg} of 100% in the humanoid phantom for projection images acquired at all angles except in the ranges of 80°–100° and 260°–280° where seeds are obscured by anatomy. This resulted in a TPR{sub trig} of 88% over the entire treatment range for considered 3D static offsets introduced to the phantom. For 2D static offsets where the position offsets were only introduced in the anterior–posterior and lateral directions, the TPR{sub trig} of SeedTracker was limited by both seed detectability and positional offset. SeedTracker showed a false positive trigger in the projection angle range between 130°–170° and 310°–350° (a maximum of 24% of treatment time) due to limited information that can be derived from monoscopic images. The system accurately determined the dynamic trajectory of the isocenter position in the superior and inferior direction for the studied dynamic offset scenarios based on the seed position in monoscopic images. Conclusions: The developed software has been shown to accurately autosegment the seed positions in kV planar images except for two 20° arcs where seeds are obscured by anatomical structures. The isocenter trajectories determined by the system, based on the monoscopic images, provide useful information for monitoring the prostate position. The developed system has potential application for monitoring prostate position during treatment delivery in linear accelerator based SBRT.

61 RADIATION PROTECTION AND DOSIMETRY↗

An improved phase shift reconstruction algorithm of fringe scanning technique for X-ray microscopy

The X-ray phase imaging method has been applied to observe soft biological tissues, and it is possible to image the soft tissues by using the benefit of the so-called “Talbot effect” by an X-ray grating. One type of the X-ray phase imaging method was reported by combining an X-ray imaging microscope equipped by a Fresnel zone plate with a phase grating. Using the fringe scanning technique, a high-precision phase shift image could be obtained by displacing the grating step by step and measuring dozens of sample images. The number of the images was selected to reduce the error caused by the non-sinusoidal component of the Talbot self-image at the imaging plane. A larger number suppressed the error more but increased radiation exposure and required higher mechanical stability of equipment. In this paper, we analyze the approximation error of fringe scanning technique for the X-ray microscopy which uses just one grating and proposes an improved algorithm. We compute the approximation error by iteration and substitute that into the process of reconstruction of phase shift. This procedure will suppress the error even with few sample images. The results of simulation experiments show that the precision of phase shift image reconstructed by the proposed algorithm with 4 sample images is almost the same as that reconstructed by the conventional algorithm with 40 sample images. We also have succeeded in the experiment with real data.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Quantifying biases in stellar masses of JWST high- z quasar host galaxies caused by quasar subtraction

The James Webb Space Telescope (JWST) has enabled dozens of high-z quasar host galaxy detections. Many of these observations imply galaxies with black holes that are overmassive compared to their low-z counterparts. However, the bright quasar point source removal can cause significant biases in recovered host magnitudes and stellar mass measurements due to the degeneracy in host galaxy and quasar light. We develop a statistical method to disentangle the quasar host galaxy stellar mass measurements from observational biases during the point source removal assuming the PSF is modelled perfectly. We use the BlueTides simulation to generate mock images and perform point source removal on thousands of simulated high-z quasar host galaxies, constructing corrected host magnitude posteriors. We find that removing a bright quasar in JWST photometry tends to either correctly recover or modestly misestimate host magnitudes, with a maximum magnitude underestimate of 0.2 mag. With our corrected magnitude posteriors, we perform SED fitting on each quasar host galaxy and compare the stellar mass measurement before and after the correction. We find that stellar mass estimates are generally robust, or misestimated by $<$ 0.3 dex. We also find that the stellar masses of a subset of hosts (J0844−0132, J0911+0152, and J1146−0005) remain unconstrained, as key photometric bands provide only flux upper limits. Accounting for observational biases does not resolve the apparent mismatch between black hole and host galaxy growth at high-z, where some quasars appear to host overmassive black holes while others reside in relatively massive galaxies.

79 ASTRONOMY AND ASTROPHYSICS↗

A Plug-and-Play Priors Approach for Solving Nonlinear Imaging Inverse Problems

In the past two decades, nonlinear image reconstruction methods have led to substantial improvements in the capabilities of numerous imaging systems. Such methods are traditionally formulated as optimization problems that are solved iteratively by simultaneously enforcing data consistency and incorporating prior models. Recently, the Plug-and-Play Priors (PPP) framework suggested that by using more sophisticated denoisers, not necessarily corresponding to an optimization objective, it is possible to improve the quality of reconstructed images. Here in this letter, we show that the PPP approach is applicable beyond linear inverse problems. In particular, we develop the fast iterative shrinkage/thresholding algorithm variant of PPP for model-based nonlinear inverse scattering. The key advantage of the proposed formulation over the original ADMM-based one is that it does not need to perform an inversion on the forward model. We show that the proposed method produces high quality images using both simulated and experimentally measured data.

97 MATHEMATICS AND COMPUTING↗

Effect of image quality on calcification detection in digital mammography

Purpose: This study aims to investigate if microcalcification detection varies significantly when mammographic images are acquired using different image qualities, including: different detectors, dose levels, and different image processing algorithms. An additional aim was to determine how the standard European method of measuring image quality using threshold gold thickness measured with a CDMAM phantom and the associated limits in current EU guidelines relate to calcification detection. Methods: One hundred and sixty two normal breast images were acquired on an amorphous selenium direct digital (DR) system. Microcalcification clusters extracted from magnified images of slices of mastectomies were electronically inserted into half of the images. The calcification clusters had a subtle appearance. All images were adjusted using a validated mathematical method to simulate the appearance of images from a computed radiography (CR) imaging system at the same dose, from both systems at half this dose, and from the DR system at quarter this dose. The original 162 images were processed with both Hologic and Agfa (Musica-2) image processing. All other image qualities were processed with Agfa (Musica-2) image processing only. Seven experienced observers marked and rated any identified suspicious regions. Free response operating characteristic (FROC) and ROC analyses were performed on the data. The lesion sensitivity at a nonlesion localization fraction (NLF) of 0.1 was also calculated. Images of the CDMAM mammographic test phantom were acquired using the automatic setting on the DR system. These images were modified to the additional image qualities used in the observer study. The images were analyzed using automated software. In order to assess the relationship between threshold gold thickness and calcification detection a power law was fitted to the data. Results: There was a significant reduction in calcification detection using CR compared with DR: the alternative FROC (AFROC) area decreased from 0.84 to 0.63 and the ROC area decreased from 0.91 to 0.79 (p < 0.0001). This corresponded to a 30% drop in lesion sensitivity at a NLF equal to 0.1. Detection was also sensitive to the dose used. There was no significant difference in detection between the two image processing algorithms used (p > 0.05). It was additionally found that lower threshold gold thickness from CDMAM analysis implied better cluster detection. The measured threshold gold thickness passed the acceptable limit set in the EU standards for all image qualities except half dose CR. However, calcification detection varied significantly between image qualities. This suggests that the current EU guidelines may need revising. Conclusions: Microcalcification detection was found to be sensitive to detector and dose used. Standard measurements of image quality were a good predictor of microcalcification cluster detection.

61 RADIATION PROTECTION AND DOSIMETRY↗

Method and system for administering internal radionuclide therapy (IRT) and external radiation therapy (XRT)

A computerized method and system for determining an optimum amount of Internal Radionuclide Therapy (IRT) and External Radiation Therapy (XRT) to administer, comprising: obtaining activity image information for an imaged object from a detector; running a Monte Carlo simulation for the activity image information to obtain absorbed dose-rate image information at multiple times; adding the absorbed dose-rate image information from each time to obtain IRT total absorbed dose image information; and utilizing the IRT total dose image information to obtain total dose image information that is equivalent to XRT dose image information in terms of dose-rate, wherein the IRT dose information is converted to equivalent XRT dose information without having to generate BED dose maps.

Sgouros, George↗

Blood flow imaging by optimal matching of computational fluid dynamics to 4D-flow data

Three-dimensional, time-resolved blood flow measurement (4D-flow) is a powerful research and clinical tool, but improved resolution and scan times are needed. Therefore, this study aims to (1) present a postprocessing framework for optimization-driven simulation-based flow imaging, called 4D-flow High-resolution Imaging with a priori Knowledge Incorporating the Navier-Stokes equations and the discontinuous Galerkin method (4D-flow HIKING), (2) investigate the framework in synthetic tests, (3) perform phantom validation using laser particle imaging velocimetry, and (4) demonstrate the use of the framework in vivo. An optimizing computational fluid dynamics solver including adjoint-based optimization was developed to fit computational fluid dynamics solutions to 4D-flow data. Synthetic tests were performed in 2D, and phantom validation was performed with pulsatile flow. Reference velocity data were acquired using particle imaging velocimetry, and 4D-flow data were acquired at 1.5 T. In vivo testing was performed on intracranial arteries in a healthy volunteer at 7 T, with 2D flow as the reference. Results Synthetic tests showed low error (0.4%-0.7%). Phantom validation showed improved agreement with laser particle imaging velocimetry compared with input 4D-flow in the horizontal (mean -0.05 vs -1.11 cm/s, P < .001; SD 1.86 vs 4.26 cm/s, P < .001) and vertical directions (mean 0.05 vs -0.04 cm/s, P = .29; SD 1.36 vs 3.95 cm/s, P < .001). In vivo data show a reduction in flow rate error from 14% to 3.5%. Phantom and in vivo results from 4D-flow HIKING show promise for future applications with higher resolution, shorter scan times, and accurate quantification of physiological parameters.

4D-flow MRI↗

SU-E-J-90: MRI-Based Treatment Simulation and Patient Setup for Radiation Therapy of Brain Cancer

Purpose: Traditional radiation therapy of cancer is heavily dependent on CT. CT provides excellent depiction of the bones but lacks good soft tissue contrast, which makes contouring difficult. Often, MRIs are fused with CT to take advantage of its superior soft tissue contrast. Such an approach has drawbacks. It is desirable to perform treatment simulation entirely based on MRI. To achieve MR-based simulation for radiation therapy, bone imaging is an important challenge because of the low MR signal intensity from bone due to its ultra-short T2 and T1, which presents difficulty for both dose calculation and patient setup in terms of digitally reconstructed radiograph (DRR) generation. Current solutions will either require manual bone contouring or multiple MR scans. We present a technique to generate DRR using MRI with an Ultra Short Echo Time (UTE) sequence which is applicable to both OBI and ExacTrac 2D patient setup. Methods: Seven brain cancer patients were scanned at 1.5 Tesla using a radial UTE sequence. The sequence acquires two images at two different echo times. The two images were processed using in-house software. The resultant bone images were subsequently loaded into commercial systems to generate DRRs. Simulation and patient clinical on-board images were used to evaluate 2D patient setup with MRI-DRRs. Results: The majority bones are well visualized in all patients. The fused image of patient CT with the MR bone image demonstrates the accuracy of automatic bone identification using our technique. The generated DRR is of good quality. Accuracy of 2D patient setup by using MRI-DRR is comparable to CT-based 2D patient setup. Conclusion: This study shows the potential of DRR generation with single MR sequence. Further work will be needed on MR sequence development and post-processing procedure to achieve robust MR bone imaging for other human sites in addition to brain.

60 APPLIED LIFE SCIENCES↗

Aggregation of Size-Selected Oxide Clusters Deposited onto Au(111)

Kinetic Monte Carlo (kMC) simulations along with density functional theory (DFT) calculations were used to investigate the aggregation of size-selected Nb 3 O y (y = 5, 6, 7) clusters deposited onto the Au(111) surface. Recent STM experiments showed that the cluster binding sites and sizes of the cluster assemblies on the Nb 3 O y /Au(111) surfaces strongly depend on the stoichiometry of the clusters, i.e., the oxygen-to-niobium ratio. To better understand the origins of these differences, kMC simulations of the nucleation and growth of cluster assemblies were performed using energy barriers for diffusion and intercluster interactions estimated from DFT calculations of cluster binding and dimerization energies, respectively. Comparisons of the kMC simulations with STM images of the as-deposited Nb 3 O y /Au(111) surfaces at RT and after high temperature annealing were used to further optimize the energetics and gauge the importance of nearest neighbor interactions. The kMC simulations demonstrate that the assembly of Nb 3 O y clusters on Au(111) are largely controlled by the magnitude of the barriers for diffusion and interparticle-bond formation, while changes at higher temperatures are sensitive to the binding energies between nearest neighbors. Simulations for the Nb 3 O 5 and Nb 3 O 6 clusters, which exhibit smaller cluster assembly sizes in STM, required larger diffusion barriers as well as different barriers for interparticle binding, which reflected differences in DFT calculated dimerization energies. Furthermore, the results demonstrate the effectiveness of combined DFT and kMC calculations for understanding how the stoichiometry affects the aggregation of small oxide clusters on a metal surface.

36 MATERIALS SCIENCE↗

Dose profile measurement using an imaging plate: Evaluation of filters using Monte Carlo simulation of 4 MV x-rays

Computed radiography (CR) is gradually replacing film. The application of CR for two-dimensional profiles and off-axis ratio (OAR) measurement using an imaging plate (IP) in a CR system is currently under discussion. However, a well known problem for IPs in dosimetry is that they use high atomic number (Z) materials, such as Ba, which have an energy dependency in a photon interaction. Although there are some reports that it is possible to compensate for the energy dependency with metal filters, the appropriate thicknesses of these filters and where they should be located have not been investigated. The purpose of this study is to find the most suitable filter for use with an IP as a dosimetric tool. Monte Carlo simulation (Geant4 8.1) was used to determine the filter to minimize the measurement error in OAR measurements of 4 MV x-rays. In this simulation, the material and thickness of the filter and distance between the IP and the filter were varied to determine most suitable filter conditions that gave the best fit to the MC calculated OAR in water. With regard to changing the filter material, we found that using higher Z and higher density material increased the effectiveness of the filter. Also, increasing the distance between the filter and the IP reduced the effectiveness, whereas increasing the thickness of the filter increased the effectiveness. The result of this study showed that the most appropriate filter conditions consistent with the calculated OAR in water were the ones with the IP sandwiched between two 2 mm thick lead filters at a distance of 5 mm from the IP or the IP sandwiched directly between two 1 mm lead filters. Using these filters, we measured the OAR at 10 cm depth with 100 cm source-to-surface distance and surface 10x10 cm{sup 2} field size. The results of this measurement represented that it is possible to achieve measurements with less than within 2.0% and 2.0% in the field and with less than 1.1% and 0.6% out of the field by using 2 and 1 mm lead filters, respectively.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗