Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “image charge”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 847 records · Page 47

Camera-on-a-Chip

Jet Propulsion Laboratory's research on a second generation, solid-state image sensor technology has resulted in the Complementary Metal- Oxide Semiconductor Active Pixel Sensor (CMOS), establishing an alternative to the Charged Coupled Device (CCD). Photobit Corporation, the leading supplier of CMOS image sensors, has commercialized two products of their own based on this technology: the PB-100 and PB-300. These devices are cameras on a chip, combining all camera functions. CMOS "active-pixel" digital image sensors offer several advantages over CCDs, a technology used in video and still-camera applications for 30 years. The CMOS sensors draw less energy, they use the same manufacturing platform as most microprocessors and memory chips, and they allow on-chip programming of frame size, exposure, and other parameters.

Source record↗

Diffraction imaging of crystals with focused x-ray beams

We describe an imaging technique based on diffraction of a focused x-ray beam in crystals. A focused beam is formed by a zone plate and Bragg diffracted from a crystalline sample positioned between the zone plate and the focus. The intensity pattern is recorded by a high-resolution charge-coupled-device detector placed in the focus. Diffraction images recorded from perfect Si and GaAs crystals for various reflections demonstrate the broadening of the focused beam due to a finite scattering length. The images from semiconductor epitaxial films and heterostructures show additional peaks originating from the interfaces with their spatial position corresponding to the depth from the surface. Diffraction images from isolated defects in Si crystal demonstrate capabilities to study bulk defects. Theoretical simulations for perfect crystals show excellent agreement with experiments. We demonstrate that the new imaging technique is depth sensitive and combines structural sensitivity of traditional x-ray topography methods with spatial in-plane resolution provided by focusing.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Suppression of the vacuum space-charge effect in fs-photoemission by a retarding electrostatic front lens

The performance of time-resolved photoemission experiments at fs-pulsed photon sources is ultimately limited by the e–e Coulomb interaction, downgrading energy and momentum resolution. Here, we present an approach to effectively suppress space-charge artifacts in momentum microscopes and photoemission microscopes. A retarding electrostatic field generated by a special objective lens repels slow electrons, retaining the k-image of the fast photoelectrons. The suppression of space-charge effects scales with the ratio of the photoelectron velocities of fast and slow electrons. Fields in the range from -20 to 01100 V/mm for E kin = 100 eV to 4 keV direct secondaries and pump-induced slow electrons back to the sample surface. Ray tracing simulations reveal that this happens within the first 40 to 3 μm above the sample surface for E kin = 100 eV to 4 keV. An optimized front-lens design allows switching between the conventional accelerating and the new retarding mode. Time-resolved experiments at E kin = 107 eV using fs extreme ultraviolet probe pulses from the free-electron laser FLASH reveal that the width of the Fermi edge increases by just 30 meV at an incident pump fluence of 22 mJ/cm2 (retarding field -21 V/mm). For an accelerating field of +2 kV/mm and a pump fluence of only 5 mJ/cm 2 , it increases by 0.5 eV (pump wavelength 1030 nm). At the given conditions, the suppression mode permits increasing the slow-electron yield by three to four orders of magnitude. The feasibility of the method at high energies is demonstrated without a pump beam at E kin = 3830 eV using hard x rays from the storage ring PETRA III. The approach opens up a previously inaccessible regime of pump fluences for photoemission experiments.

47 OTHER INSTRUMENTATION↗

Shaped Beams from Diamond Field-Emitter Array Cathodes

Diamond field-emitter arrays (DFEAs) are arrays of diamond pyramids with exquisitely sharp tips and micrometer-scale bases that produce high current densities. These arrays can be fabricated in arbitrary shapes, ranging from single tips to many millions of tips, so that they produce an inherently shaped electron beam. Each tip emits a modest current, but the large dense array can produce many Amps. We are investigating these cathodes for use in dielectric wakefield accelerators; however, they may also be applicable to vacuum microwave tubes. Recently, shaped beam production and transport have been demonstrated in the 1.3-GHz RF gun at the Argonne Cathode Test Stand at the Argonne National Laboratory. The charge was measured on a Faraday cup and the beam imaged on a YAG screen with peak electric field gradients on the cathode ranging from 12 to 35 MV/m. Three cathode geometries were tested: one 1-mm equilateral triangle with 7-mu m base pyramids and 10-mu m pitch, one 1-mm equilateral triangle with 10-mu m base and 25-mu m pitch, and one sparse 5 x 5 square array with 20-mu m base and 400-mu m pitch. The two triangular arrays emitted 35 nC in an RF macropulse at 35 MV/m and 13-nC charge at 27 MV/m, respectively, while the sparse array emitted 0.060-nC charge at 15 MV/m. This article presents the results of the triangular array experiments, including damage due to breakdown in the RF gun and initial models of tip-to-tip shielding.

Cathodes↗

Surface conversion techniques for low energy neutral atom imagers

This investigation has focused on development of key technology elements for low energy neutral atom imaging. More specifically, we have investigated the conversion of low energy neutral atoms to negatively charged ions upon reflection from specially prepared surfaces. This 'surface conversion' technique appears to offer a unique capability of detecting, and thus imaging, neutral atoms at energies of 0.01 - 1 keV with high enough efficiencies to make practical its application to low energy neutral atom imaging in space. Such imaging offers the opportunity to obtain the first instantaneous global maps of macroscopic plasma features and their temporal variation. Through previous in situ plasma measurements, we have a statistical picture of large scale morphology and local measurements of dynamic processes. However, with in situ techniques it is impossible to characterize or understand many of the global plasma transport and energization processes. A series of global plasma images would greatly advance our understanding of these processes and would provide the context for interpreting previous and future in situ measurements. Fast neutral atoms, created from ions that are neutralized in collisions with exospheric neutrals, offer the means for remotely imaging plasma populations. Energy and mass analysis of these neutrals provides critical information about the source plasma distribution. The flux of neutral atoms available for imaging depends upon a convolution of the ambient plasma distribution with the charge exchange cross section for the background neutral population. Some of the highest signals are at relatively low energies (well below 1 keV). This energy range also includes some of the most important plasma populations to be imaged, for example the base of the cleft ion fountain.

Quinn, J. M.↗

Fractal Scaling of Explosively Driven Product Gases

ABSTRACT Characterization of the interface between explosive product gases and ambient air in an explosion is a complicated task due to the turbulent mixing and inherently three‐dimensional expansion of the interface. This study aims to quantify the evolution of the interface as a temporally varying Hausdorff dimension. Two test series were conducted with Composition C‐4 charges with masses of 105 and 880 g. Imaging data were collected from the time of detonation until shock wave detachment using ultra‐high‐speed cameras. Gas cloud profiles were extracted using automated image processing algorithms, and the Hausdorff dimension of these two‐dimensional slices of the gas cloud was then estimated using boxcounting algorithms. When scaled with standard gas dynamic nondimensional scalings, the Hausdorff dimension of all explosive events appears to collapse towards a single curve. The fireball was initially nonfractal and began to develop fractal properties as the shock wave separated from the detonation products. Artificial perturbation of the charged surface had no detectable impact on the evolution of the Hausdorff dimension in the early development of the fireball outside of error, despite visible phenomenological differences in the early development of mixing on the fireball surface.

42 ENGINEERING↗

Cameras Would Withstand High Accelerations

Very rugged cameras with all-reflective optics proposed for use in presence of high accelerations. Optics consist of four coaxial focusing mirrors in Cassegrain configuration. Mirrors are conics or aspherics. Optics achromatic,and imaging system overall passes light from extreme ultraviolet to far infrared. Charge-coupled-device video camera, film camera, or array of photodetectors placed at focal plane. Useful as portable imagers subject to rough handling, or instrumentation cameras mounted on severely vibrating or accelerating vehicles.

Meinel, Aden B.↗

Dual-sided charge-coupled devices

Existing charge-coupled devices (CCDs) operate by detecting either the electrons or holes created in an ionization event. Here, we propose an imager, the dual-sided CCD, which collects and measures both charge carriers on opposite sides of the device via a dual-buried channel architecture. We show that this dual detection strategy provides exceptional dark-count rejection and enhanced timing capabilities. These advancements have wide-ranging implications for dark-matter searches, near-infrared/optical spectroscopy, and time-domain x-ray astrophysics.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A CONVENIENT SOLUTION TO GEOMETRIC DISTORTION AND ITS APPLICATION TO PHOEBE'S OBSERVATIONS

A simple but effective approach is proposed for measuring the geometric distortion of a CCD field of view of a ground-based telescope. For three open clusters (M35, M67, and NGC 2324), 425 CCD frames taken by a 1 m telescope at the Yunnan Observatory are used to test this approach. It is found that the geometric distortion pattern depends strongly on the corresponding filter used. The geometric distortion is then used to correct the pixel positions for Phoebe, the ninth satellite of Saturn, and its reference stars imaged in 220 CCD frames taken by the same telescope. The standard deviation of the (O - C; observed minus computed) residuals of Phoebe is significantly improved after correcting the geometric distortions.

79 ASTRONOMY AND ASTROPHYSICS↗

Calibration of X-ray imaging devices for accurate intensity measurement

National Security Technologies (NSTec) has developed calibration procedures for X-ray imaging systems using NIST traceable sources. The X-ray sources that are used for calibration are both diode type and diode/fluorescer combinations. Calibrating the X-ray detectors is the key to accurate calibration of the X-ray sources. Both energy dispersive detectors and photodiodes measuring total flux were used. We have developed calibration techniques for the detectors using radioactive sources that are traceable to the National Institute of Standards and Technology (NIST). The German synchrotron at Physikalische Technische Bundestalt (PTB) is used to calibrate silicon photodiodes over the energy range from 50 eV to 60 keV. The measurements on X-ray cameras made using the NSTec X-ray sources have included the quantum efficiency averaged over all pixels, the camera counts per photon per pixel, and response variation across the sensor. The instrumentation required to accomplish the calibrations is described. X-ray energies ranged from 720 eV to 22.7 keV. The X-ray sources produce narrow energy bands, allowing us to determine the properties as a function of X-ray energy. The calibrations were done for several types of imaging devices. There were back illuminated and front illuminated CCD (charge coupled device) sensors, and a CID (charge injection device) type camera. The CCD and CID camera types differ significantly in some of their properties that affect the accuracy of X-ray intensity measurements. All cameras discussed here are silicon based. The measurements of quantum efficiency variation with X-ray energy are compared to models for the sensor structure. Cameras that are not back-thinned are compared to those that are.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The AXAF CCD Imaging Spectrometer Experiment (ACIS)

The ACIS experiment consists of an array of charge coupled device (CCD) chips placed at the focus of the AXAF mirror assembly. The instrument offers a powerful combination of the best qualities of the entire generation of Einstein Observatory detectors. The pixel size is well matched to the resolution of the telescope, while the high quantum efficiency nondispersive spectroscopy capability means that every object imaged will produce a moderate resolution spectrum. In conjunction with the objective gratings the energy resolution increases to 1000 with a loss of efficiency of only 50 percent. While the great capability of ACIS will naturally make it attractive for a wide range of AXAF investigations, ACIS has a particular advantage in fields where it can simultaneously acquire imaged spectra of many objects. These include compact star clusters, star formation regions, the nuclear regions of nearby galaxies, entire galaxies in the Virgo Cluster and the entire Coma Cluster.

Nousek, J. A.↗

WE-H-207A-01: Computational Evaluation of High-Resolution 18F Positron Imaging Using Radioluminescence Microscopy with Lu2O3: Eu Thin-Film Scintillator

Purpose: Radioluminescence microscopy, an emerging and powerful tool for high resolution beta imaging, has been applied to molecular imaging of cellular metabolism to understand tumor biology. A novel thin-film (10 µm thickness) scintillator made of Lu{sub 2}O{sub 3}: Eu has been developed to enhance the system performance. However the advances of radioluminescence imaging with Lu{sub 2}O{sub 3}scintillator compared with that using conventional scintillator have not been explored theoretically to date. To validate the advantages of the thin-film scintillator, this study uses a novel computational simulation framework to evaluate the performance of radioluminescence microscopy using both conventional and thin-film scintillators. Methods: Numerical models for different stages of positron imaging are established. Positron from {sup 18}F passing through the scintillator and its neighbor structures are modeled by Monte-Carlo simulation using Geant4. The propagation and focus of photons by the microscope are modeled by convolution with a depth-varying point spread function generated by the Gibson-Lanni model. Photons focused on the detector plane are then captured and converted into electronic signals by an electron multiplication (EM) CCD camera, which is described by a photosensor model considering various noises and charge amplification. Results: The performance metrics of radioluminescence imaging with a thin-film Lu{sub 2}O{sub 3} and conventional CdWO{sub 4} scintillator are compared, including spatial resolution, sensitivity, positron track area and intensity. The spatial resolution of Lu{sub 2}O{sub 3} system can achieve 10 µm maximally, a 12 µm enhancement from that obtained from CdWO{sub 4} system. Meanwhile, the system with Lu{sub 2}O{sub 3} scintillator can provide a higher mean sensitivity: 40% compared with that (21.5%) obtained from CdWO{sub 4} system. Moreover, the simulation results are in good agreement with previous experimental measurements. Conclusion: This study provides a new theoretical understanding of our imaging system and has the potential to promote the development of radioluminescence microscopy for more reliable and robust application on the functional imaging of delicate biological structures. The authors acknowledge funding from NIH grant R01CA186275 and SBIR grant 1R43GM110888-01.

60 APPLIED LIFE SCIENCES↗

Charge density wave in a band insulator

Charge-density-wave implies a periodic modulation of the charge density. Typically observed in metallic systems, charge-density-wave arise from Fermi surface instabilities, resulting in the total or partial gapping of the Fermi surface. Here, we present experimental evidence for a charge-density wave state emerging in a band insulator which has no Fermi surface. The bulk and surface of our material platform, 𝛂-Bi 4 Br 4 , is gapped over the entire Brillouin zone. Through topographic and spectroscopic imaging at low temperatures, we unveil an unexpected unidirectional charge modulation in 𝛂-Bi 4 Br 4 , breaking the lattice translation symmetry. The charge-density-wave develops at temperatures below 40 K and adds an energy gap atop the existing insulating gap of 𝛂-Bi 4 Br 4 . Furthermore, our transport measurements reveal nonlinear electrical conduction, a phenomenon conventionally associated with the sliding or phason mode of incommensurate charge-density-waves. These unusual observations represent a different type of charge-density-wave

Phase transitions and critical phenomena↗

Modeling of Proton-Induced CCD Degradation in the Chandra X-Ray Observatory

Modeling results are presented for proton-induced degradation of charge-coupled devices (CCDs) used in the Advanced CCD Imaging Spectrometer instrument on the Chandra X-Ray Observatory. A methodology is described that provides insights regarding degradation mechanism and on-orbit performance for front-illuminated and back-illuminated CCDs Proton-induced changes in charge transfer inefficiency are modeled. The observed amount of on-orbit degradation can be accounted for using a proton spectrum at the CCD location that is reduced in magnitude by a factor of approx. 1E5 compared to the spectrum incident on the spacecraft.

Lo, D. H.↗

Electrostatic Asymmetry of Wurtzite Nanocrystals and Resulting Photocatalytic Properties

Efficient light absorption and high energy of charge carriers of zinc cadmium sulfide (ZCS) make this semiconductor attractive for many photocatalytic reactions. Despite marked successes in shape-controlled synthesis of ZCS central to their photocatalytic performance, recombination of charge carriers as they migrate through the nanoscale particles results in losses of excitation energy, markedly reducing the photocatalytic activity of ZCS and other heterogeneous photocatalysts. Here, in this study, we show that the electrostatic asymmetry of nanostructures, previously discovered for nearly spherical nanoparticles, also manifests in wurtzite ZCS with planar geometry. The electrostatic asymmetry assists charge separation and substantially increases the yield of photocatalytic reactions in monocrystalline ZCS. The synthesized ZCS nanorods and nanoplates with identical chemical composition were found to have markedly different photocatalytic activity for evolution of hydrogen in water. Despite much smaller specific surface areas, the ~500 nm wide nanoplates displayed a hydrogen evolution rate 12 times higher than the ~35 nm long nanorods, also outperforming other ZCS photocatalysts. Experimental and computational data indicate that the homo- and heterojunction-free ZCS nanoplates with continuous wurtzite lattice behave essentially as nanoscale dipoles with intrinsic dipole moment as high as 48.39 D per unit cell. Electric-field-directed migration of charge carriers stimulates their localization on opposite parts of the nanoplates. Direct imaging of the intraparticle electrical field using off-axis electron holography confirmed their electrostatic asymmetry. Polarization-enhanced charge separation provides a new pathway to efficient and stable photocatalysts for sustainable energy technologies.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Performance Analysis of Li-ion Battery Under Various Thermal and Load Conditions

In the recent years, with the rapid advancements made in the technologies of electric and hybrid electric vehicles, selecting suitable batteries has become a major factor. Among the batteries currently used for these types of vehicles, the lithium-ion battery leads the race. Apart from that, the energy gained from regenerative braking in locomotives and vehicles can be stored in batteries for later use for propulsion thus improving the fuel consumption and efficiency. But batteries can be subjected to a wide range of temperatures depending upon the operating conditions. Thus, a thorough knowledge of the battery performance over a wide range of temperatures and different load conditions is necessary for their successful employment in future technologies. In this context, this study aims to experimentally analyze the performance of Li-ion batteries by monitoring the charge–discharge rates, efficiencies, and energy storage capabilities under different environmental and load conditions. Sensors and thermal imaging camera were used to track the environment and battery temperatures, whereas the charge–discharge characteristics were analyzed using CADEX analyzer. The results show that the battery performance is inversely proportional to charge–discharge rates. This is because, at higher charge–discharge rates, the polarization losses increase thus increasing internal heat generation and battery temperature. Also, based on the efficiency and energy storage ability, the optimum performing conditions of the Li-ion battery are 30–40 °C (temperature) and 0.5 C (C-rate).

25 ENERGY STORAGE↗

Spontaneous pairing and cooperative movements of micro-particles in a two dimensional plasma crystal

In an argon plasma of 20 W rf discharge at a pressure of 1.38 Pa, a stable highly ordered monolayer of microparticles is suspended. We observe spontaneous particle pairing when suddenly reducing the gas pressure. Special types of dynamical activity, in particular, entanglement and cooperative movements of coupled particles have been registered. In the course of the experiment first appeared single vertical pairs of particles, in further they gradually accumulated causing melting of the entire crystal. To record pairing events, the particle suspension is side-view imaged using a vertically extended laser sheet. The long-lasting pre-melting phase assured the credible recording and identification of isolated particle pairs. The high monolayer charge density is crucial to explain the spontaneous pairing events observed in our experiments as the mutual repulsion between the particles comprising the monolayer make its vertical extend thicker.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗