Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “human performance measures”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 847 records · Page 47

Introducing Human Mandible Identification [(hu)MANid]: A Free, Web‐Based GUI to Classify Human Mandibles

Abstract Statistical programs have revolutionized the way in which forensic anthropologists conduct casework by allowing practitioners to use computationally complex analytics at the click of a button. Importantly, the products of these statistical programs are reproducible and contain measures of error or uncertainty, thereby strengthening conclusions. This paper is an introduction to (hu) MAN id, a free, web‐based application that uses linear and mixture discriminant function analyses to classify human mandibles into one of many worldwide and/or periodic reference groups. The mechanics, development, and use of the application will be discussed. Further, the program was tested against other software to compare model performances and classifications. Total correct classifications among the test cases and programs were identical. Ten mandibles were tested using both statistical procedures. Mixture discriminant analysis improved classification by an average of 9.3% and correctly identified three more mandibles than LDA . Therefore, we believe (hu) MAN id will be an asset to the anthropological community.

Berg, Gregory E.↗

Performance Visualization for TAU Instrumented Scientific Workflows

In exascale scientific computing, it is essential to efficiently monitor, evaluate and improve performance. Visualization and especially visual analytics are useful and inevitable techniques in the exascale computing era to enable such a human-centered experience. In this ongoing work, we present a visual analytics framework for performance evaluation of scientific workflows. Ultimately, we aim to solve two current challenges: the capability to deal with workflows, and the scalability toward exascale scenario. On the way to achieve these goals, in this work, we first incorporate TAU (Tuning and Analysis Utilities) instrumentation tool and improve it to accommodate workflow measurements. Then we establish a web-based visualization framework, whose back end handles data storage, query and aggregation, while front end presents the visualization and takes user interaction. In order to support the scalability, a few level-of-detail mechanisms are developed. Finally, a chemistry workflow use case is adopted to verify our methods

97 MATHEMATICS AND COMPUTING↗

Chemical research projects office functions accomplishments programs

Basic and applied research in the fields of polymer chemistry, polymeric composites, chemical engineering, and biophysical chemistry is summarized. Emphasis is placed on fire safety and human survivability as they relate to commercial and military aircraft, high-rise buildings, mines and rapid transit transportation. Materials systems and other fire control systems developed for aerospace applications and applied to national domestic needs are described along with bench-scale and full-scale tests conducted to demonstrate the improvements in performance obtained through the utilization of these materials and fire control measures.

Heimbuch, A. H.↗

Baseline experiments in teleoperator control

Studies have been conducted at the NASA Langley Research Center (LaRC) to establish baseline human teleoperator interface data and to assess the influence of some of the interface parameters on human performance in teleoperation. As baseline data, the results will be used to assess future interface improvements resulting from this research in basic teleoperator human factors. In addition, the data have been used to validate LaRC's basic teleoperator hardware setup and to compare initial teleoperator study results. Four subjects controlled a modified industrial manipulator to perform a simple task involving both high and low precision. Two different schemes for controlling the manipulator were studied along with both direct and indirect viewing of the task. Performance of the task was measured as the length of time required to complete the task along with the number of errors made in the process. Analyses of variance were computed to determine the significance of the influences of each of the independent variables. Comparisons were also made between the LaRC data and data taken earlier by Grumman Aerospace Corp. at their facilities.

Hankins, W. W., III↗

Alendronate as an Effective Countermeasure to Disuse Induced Bone loss

Microgravity, similar to diuse immobilization on earth, causes rapid bone loss. This loss is believed to be an adaptive response to the reduced musculoskelatal forces in space and occurs gradually enough that changes occurring during short duration space flight are not a concern. Bone loss, however, will be a major impediment for long duration missions if effective countermeasures are not developed and implemented. Bed rest is used to simulate the reduced mechanical forces in humans and was used to test the hypothesis that oral alendronate would reduce the effects of long duration (17 weeks) inactivity on bone. Eight male subjects were given daily oral doses of alendronate during 17 weeks of horizontal bed rest and compared with 13 male control subjects not given the drug. Efficacy was evaluated based on measurements of bone markers, calcium balance and bone density performed before, during and after the bed rest. The results show that oral alendronate attenuates most of the characteristic changes associated with long duration bed rest and presumably space flight.

LeBlanc, Adrian D.↗

UAS Integration into the NAS: Detect and Avoid Display Evaluations in Support of SC-228 MOPS Development

This presentation provides an overview of the work the Human Systems Integration (HSI) sub-project has done on detect and avoid (DAA) displays while working on the UAS Integration into the NAS project. Much of the work has been used to support the ongoing development of minimum operational performance standards (MOPS) for UAS by RTCA Special Committee 228. The design and results of three different human-in-the-loop simulations are discussed, with particular emphasis on the role of the UAS pilot in the Self Separation Timeline.

unmanned aircraft systems↗

Habitability Assessments And Lessons-learned From 3-day And 11-day Enriched Oxygen Hypobaric Chamber Tests At NASA Johnson Space Center

INTRODUCTION: Decompression sickness (DCS) is a risk to the health and performance of astronauts and high-altitude aircrew. Tolerance to flammability, hypoxia, prebreathe duration, and DCS risk varies across different organizations, vehicles, suits, and destinations, necessitating a variety of DCS risk mitigation approaches. Existing models of altitude DCS risk are often insufficient to enable accurate risk-informed decisions during hardware development, mission planning, and flight operations. METHODS: NASA completed outfitting of a dedicated facility at Johnson Space Center to support testing of up to eight human subjects for multiple days in hypobaric and enriched oxygen atmospheres. The primary purpose of the testing capability is validation of DCS risk mitigation protocols for Artemis missions to the Moon; however, it will also support development and validation of a generalizable altitude DCS risk estimation tool. A 3-day and an 11-day prebreathe validation test were completed in 2022, each with 8 human subjects living at 56.5 kPa (8.2 psia), 34% O2, 66% N2, with 5 simulated EVAs performed on masks at 29.6 kPa (4.3 psi), 85% O2, 15% N2. Facility and organizational lessons-learned and process improvements were recorded during and following the tests, and subjective habitability ratings were recorded daily during the 11-day test. Hypoxia and DCS-related physiological and cognitive outcome measures were recorded during both tests and are reported in companion presentations. RESULTS & DISCUSSION: All subjects completed each of the tests. Primary habitability issues related to mask discomfort during simulated EVAs and poor sleep quality due to thin mattresses. Polybenzimidazole (PBI) clothing was worn by all subjects due to the increased fire risk and may be required for Artemis missions; clothing was found to be acceptable overall with the worst ratings being due to poor fit and inelasticity. Chamber O2 and CO2 sensor inconsistency was observed that did not result in test termination but required post-test follow-up. Forward plans include additional hypobaric testing and integration of existing and future physiological outcome data into an open-source Aerospace Estimation Tool for Hypobaric Exposure Risk (AETHER). NASA is also working to make the testing capability available to commercial companies.

Andrew F J Abercromby↗

Habitability Assessments And Lessons-learned From 3-day And 11-day Enriched Oxygen Hypobaric Chamber Tests At NASA Johnson Space Center

INTRODUCTION: Decompression sickness (DCS) is a risk to the health and performance of astronauts and high-altitude aircrew. Tolerance to flammability, hypoxia, prebreathe duration, and DCS risk varies across different organizations, vehicles, suits, and destinations, necessitating a variety of DCS risk mitigation approaches. Existing models of altitude DCS risk are often insufficient to enable accurate risk-informed decisions during hardware development, mission planning, and flight operations. METHODS: NASA completed outfitting of a dedicated facility at Johnson Space Center to support testing of up to eight human subjects for multiple days in hypobaric and enriched oxygen atmospheres. The primary purpose of the testing capability is validation of DCS risk mitigation protocols for Artemis missions to the Moon; however, it will also support development and validation of a generalizable altitude DCS risk estimation tool. A 3-day and an 11-day prebreathe validation test were completed in 2022, each with 8 human subjects living at 56.5 kPa (8.2 psia), 34% O2, 66% N2, with 5 simulated EVAs performed on masks at 29.6 kPa (4.3 psi), 85% O2, 15% N2. Facility and organizational lessons-learned and process improvements were recorded during and following the tests, and subjective habitability ratings were recorded daily during the 11-day test. Hypoxia and DCS-related physiological and cognitive outcome measures were recorded during both tests and are reported in companion presentations. RESULTS & DISCUSSION: All subjects completed each of the tests. Primary habitability issues related to mask discomfort during simulated EVAs and poor sleep quality due to thin mattresses. Polybenzimidazole (PBI) clothing was worn by all subjects due to the increased fire risk and may be required for Artemis missions; clothing was found to be acceptable overall with the worst ratings being due to poor fit and inelasticity. Chamber O2 and CO2 sensor inconsistency was observed that did not result in test termination but required post-test follow-up. Forward plans include additional hypobaric testing and integration of existing and future physiological outcome data into an open-source Aerospace Estimation Tool for Hypobaric Exposure Risk (AETHER). NASA is also working to make the testing capability available to commercial companies.

Andrew Abercromby↗

Inferring ultraviolet anatomical exposure patterns while distinguishing the relative contribution of radiation components

Exposure to solar ultraviolet (UV) radiation is the main causative factor for skin cancer. UV exposure depends on environmental and individual factors, but individual exposure data remain scarce. While ground UV irradiance is monitored via different techniques, it is difficult to translate such observations into human UV exposure or dose because of confounding factors. A multi-disciplinary collaboration developed a model predicting the dose and distribution of UV exposure on the basis of ground irradiation and morphological data. Standard 3D computer graphics techniques were adapted to develop a simulation tool that estimates solar exposure of a virtual manikin depicted as a triangle mesh surface. The amount of solar energy received by various body locations is computed for direct, diffuse and reflected radiation separately. Dosimetric measurements obtained in field conditions were used to assess the model performance. The model predicted exposure to solar UV adequately with a symmetric mean absolute percentage error of 13% and half of the predictions within 17% range of the measurements. Using this tool, solar UV exposure patterns were investigated with respect to the relative contribution of the direct, diffuse and reflected radiation. Exposure doses for various body parts and exposure scenarios of a standing individual were assessed using erythemally-weighted UV ground irradiance data measured in 2009 at Payerne, Switzerland as input. For most anatomical sites, mean daily doses were high (typically 6.2-14.6 Standard Erythemal Dose, SED) and exceeded recommended exposure values. Direct exposure was important during specific periods (e.g. midday during summer), but contributed moderately to the annual dose, ranging from 15 to 24% for vertical and horizontal body parts, respectively. Diffuse irradiation explained about 80% of the cumulative annual exposure dose.

61 RADIATION PROTECTION AND DOSIMETRY↗

A New Black Carbon Sensor for Dense Air Quality Monitoring Networks

Low-cost air pollution sensors are emerging and increasingly being deployed in densely distributed wireless networks that provide more spatial resolution than is typical in traditional monitoring of ambient air quality. However, a low-cost option to measure black carbon (BC)—a major component of particulate matter pollution associated with adverse human health risks—is missing. This paper presents a new BC sensor designed to fill this gap, the Aerosol Black Carbon Detector (ABCD), which incorporates a compact weatherproof enclosure, solar-powered rechargeable battery, and cellular communication to enable long-term, remote operation. This paper also demonstrates a data processing methodology that reduces the ABCD’s sensitivity to ambient temperature fluctuations, and therefore improves measurement performance in unconditioned operating environments (e.g., outdoors). A fleet of over 100 ABCDs was operated outdoors in collocation with a commercial BC instrument (Magee Scientific, Model AE33) housed inside a regulatory air quality monitoring station. The measurement performance of the 105 ABCDs is comparable to the AE33. The fleet-average precision and accuracy, expressed in terms of mean absolute percentage error, are 9.2 ± 0.8% (relative to the fleet average data) and 24.6 ± 0.9% (relative to the AE33 data), respectively (fleet-average ± 90% confidence interval).

47 OTHER INSTRUMENTATION↗

Study of blood flow sensing with microwave radiometry

A study and experimental investigation has been performed to determine the feasibility of measuring regional blood flow and volume in man by means of microwave radiometry. An indication was expected of regional blood flow from measurement of surface and subsurface temperatures with a sensitive radiometer. Following theoretical modeling of biological tissue, to determine the optimum operating frequency for adequate sensing depth, a sensitive microwave radiometer was designed for operation at 793 MHz. A temperature sensitivity of of 0.06 K rms was realized in this equipment. Measurements performed on phantom tissue models, consisting of beef fat and lean beefsteak showed that the radiometer was capable of sensing temperatures from a depth between 3.8 and 5.1 cm. Radiometric and thermodynamic temperature measurements were also performed on the hind thighs of large dogs. These showed that the radiometer could sense subsurface temperatures from a depth of, at least, 1.3 cm. Delays caused by externally-generated RF interference, coupled with the lack of reliable blood flow measurement equipment, prevented correlation of radiometer readings with reginal blood flow. For the same reasons, it was not possible to extend the radiometric observations to human subjects.

Porter, R. A.↗

Detectability of auditory signals presented without defined observation intervals

Ability to detect tones in noise was measured without defined observation intervals. Latency density functions were estimated for the first response following a signal and, separately, for the first response following randomly distributed instances of background noise. Detection performance was measured by the maximum separation between the cumulative latency density functions for signal-plus-noise and for noise alone. Values of the index of detectability, estimated by this procedure, were approximately those obtained with a 2-dB weaker signal and defined observation intervals. Simulation of defined- and non-defined-interval tasks with an energy detector showed that this device performs very similarly to the human listener in both cases.

Watson, C. S.↗

Interaction between workload and training - Converging evidence from psychophysiology and performance measurement

Traditionally, the domains of mental workload and training have been studied in isolation even though they share many common characteristics. The present paper integrates findings from psychophysiological and performance-based studies which address both of these issues. By augmenting traditional indices of skill acquisition such as RMS error scores, reaction times, and accuracy measures with psychophysiological measures such as the event-related brain potential, it is shown that workload effects can be assessed throughout the training process. More specifically, it is argued that the development of skill and the effects of workload on the human operator can be modeled within the framework of resource theories of attentional allocation. Also described is how converging evidence from psychophysiological and behavioral studies can be used to examine subtle changes in operator strategies during training.

Kramer, Arthur F.↗

Psychological and Behavioral Health Issues of Long-Duration Space Missions

It will be the responsibility of the long-duration space flight crew to take the actions necessary to maintain their health and well-being and to cope with medical emergencies without direct assistance from support personnel, including maintaining mental health and managing physiological and psychological changes that may impair decision making and performance. The Behavior and Performance Integrated Product Team at Johnson Space Center, working, within the Space Medicine, Monitoring, and Countermeasures Program, has identified critical questions pertaining to long-duration space crew behavioral health, psychological adaptation, human factors and habitability, and sleep and circadian rhythms. Among the projects addressing these questions are: the development of tools to assess cognitive functions during space missions; the development of a model of psychological adaptation in isolated and confined environments; tools and methods for selecting individuals and teams well-suited for long-duration missions; identification of mission-critical tasks and performance evaluation; and measures of sleep quality and correlation to mission performance.

Eksuzian, Daniel J.↗

Lunar Flashlight: Illuminating the Lunar South Pole

Lunar Flashlight is an innovative, small NASA mission to be launched as a secondary payload on the Space Launch System Exploration Mission 1 (EM-1). This highly mass- and volume-constrained satellite will demonstrate several technologies for NASA, including the use of "green" propellant, the ability for a CubeSat-sized satellite to perform science measurements beyond low Earth orbit, and the first planetary mission to use multi-band active reflectometry from orbit. Lunar Flashlight will detect and map water ice in permanently shadowed regions of the lunar south pole by measuring surface reflectance at multiple wavelengths. Mapping and quantifying lunar water ice addresses one of NASA's Strategic Knowledge Gaps to understand the lunar resource potential for future human exploration of the Moon.

Barbara Cohen↗

RADIOISOTOPE IDENTIFICATION OF SHIELDED AND MASKED SNM RDD MATERIALS

Sonar and speech techniques have been investigated to improve functionality and enable handheld and other man-portable, mobile, and portal systems to positively detect and identify illicit nuclear materials, with minimal data and with minimal false positives and false negatives. RadSonar isotope detection and identification is an algorithm development project funded by NA-22 and employing the resources of Savannah River National Laboratory and three University Laboratories (JHU-APL, UT-ARL, and UW-APL). Algorithms have been developed that improve the probability of detection and decrease the number of false positives and negatives. Two algorithms have been developed and tested. The first algorithm uses support vector machine (SVM) classifiers to determine the most prevalent nuclide(s) in a spectrum. It then uses a constrained weighted least squares fit to estimate and remove the contribution of these nuclide(s) to the spectrum, iterating classification and fitting until there is nothing of significance left. If any Special Nuclear Materials (SNMs) were detected in this process, a second tier of more stringent classifiers are used to make the final SNM alert decision. The second algorithm is looking at identifying existing feature sets that would be relevant in the radioisotope identification context. The underlying philosophy here is to identify parallels between the physics and/or the structures present in the data for the two applications (speech analysis and gamma spectroscopy). The expectation is that similar approaches may work in both cases. The mel-frequency cepstral representation of spectra is widely used in speech, particularly for two reasons: approximation of the response of the human ear, and simplicity of channel effect separation (in this context, a 'channel' is a method of signal transport that affects the signal, examples being vocal tract shape, room echoes, and microphone response). Measured and simulated gamma-ray spectra from a hand-held Radioisotope Identification Device were used to evaluate the algorithms. This paper will present and discuss results of the Test and Evaluation performed on two algorithms produced from the project.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Insight into mechanisms of reduced orthostatic performance after exposure to microgravity: comparison of ground-based and space flight data

Since the beginning of human spaceflight, the value of understanding mechanisms of physiological adaptation to microgravity became apparent to life scientists who were interested in maintining crew health and developing countermeasures agains adverse effects of the mission. However, several characteristics associated the the logistics of spaceflight presented significant limitations to the scientific study of human adaptation to microgravity. Because space missions are so infrequent and involve minimal numbers of crewmembers, meaninful statistical analysis of data are limited. Reproducibility of results from spaceflight experiments is difficult to assess since there are few repeated space missions involving the same crewmembers. Since the emphasis of space missions is placed on operations, experiments are compromised without adequate control over various factors (e.g., time, diet, physical activities, etc.) that can impact measured responses. With the mimimal opportunity to collect spaceflight data, there is a high risk of experiments that simultaneously interfere with other experiments by the increasing demand on the crewmembers to participate in mumerous experiments proposed by multiple investigators. The technology and ability to measure physiological functions necessary to test specific hypotheses can be severely limited by physical space and power constraints of the space enviroment. Finally, technical and logistical aspects of space missions such as launch delays, extended missions, and inflight operational emergencies can significantly compromise the timing and control of experiments. These limitations have stimulated scientists to develop ground-based analogs of microgravity in an effort to investigate the effects of spaceflight on physiological function in a controlled experimental setting. The purpose of this paper is to provide a selected comparison of data collected from ground-based experiments with those obtained from spaceflight in an effort to assess the adequacy of ground analogs of actual flight for the study of human physiological adaptation to microgravity. Specifically, results from ground and spaceflight will be used to provide insight into mechanisms underlying adaptations of blood pressure regulation and reduced orthostatic performance to the microgravity environment.

Non-NASA Center↗

Rapidly Assessing the Quality of Targeted Proteomics Experiments through Monitoring Stable-Isotope Labeled Standards

Selected reaction monitoring (SRM), also known as multiple reaction monitoring (MRM), is a data acquisition technique used in targeted analysis of molecules, including targeted proteomic studies. It exploits the unique capability of triple-quadrupole (QQQ) mass spectrometers to monitor the predefined precursor and fragment ion pairs of specific molecules of interest throughout a liquid chromatography (LC) elution profile. Compared to shotgun proteomics, targeted proteomics using SRM has high selectivity, high sensitivity, and a wide linear dynamic range,(1-3) which makes it especially useful in the accurate and reproducible quantification of low-abundance proteins in highly complex biological samples. SRM has been widely used in the fields of biomarker discovery,(4-7) analysis of protein post-translational modifications(8) and characterization of biological protein networks.(4,9) In the recent years, multiple technical advances have greatly improved the throughput of SRM analyses, allowing for the quantification of hundreds of peptides in a single analysis.(6,7,10) For example, a single 800-plex SRM assay (e.g., 400 unlabeled and heavy-labeled peptide pairs and 2400 transitions with retention time scheduling) using ultrahigh-performance liquid chromatography (UHPLC) has been developed to quantify proteins in plasma.(11) Advanced labeling techniques utilizing in vitro proteome-assisted MRM for protein absolute quantification (iMPAQT) demonstrated the capability of SRM in genome-wide protein quantification of over 18?000 human proteins.(12) Moreover, the scan speed of QQQ instrumentation has been greatly improved in recent releases of commercial instrumentation. The newly developed TSQ Altis (released in 2017) can scan more than 600 transitions per second, which is 6 times more than a traditional QQQ scan speed of 100 transitions per second. The breadth of measurement enabled by these technological improvements to QQQ mass spectrometry has increased the feasibility and popularity of large scale targeted proteomics studies,(13) a major application of which will be in clinical studies in which up to hundreds of protein candidates need to be quantified in hundreds of clinical specimens.(14) Quantitative accuracy is a primary motivating factor for utilizing a targeted proteomics protocol. The precise and reproducible absolute quantification produced by SRM assays is essential to many clinical and laboratory experiments.(15,16) Because the abundance of an endogenous peptide is calculated from the measurement of the spiked-in reference standard, it is essential to assess the data quality of these references.(17) In early applications of targeted proteomics, when instrument speed greatly limited the number of transitions that could be monitored, much of this quality assessment was done manually. However, recent improvements in instrument performance and experimental design have enabled a dramatic increase in the number of target peptides and associated SRM transitions, which makes manual quality assessment an untenable and laborious task. A variety of computational tools assist in SRM experiment design and data analysis. The first task in creating an SRM experiment is the choice of proteins and representative peptides to monitor. Achieving a reliable protein abundance requires appropriately choosing peptides that have a strong signal and are free from interferences in the biological matrix. Numerous computational tools exist to facilitate assay design by identifying peptides and refining SRM transitions.(18-21) To help share these assays and eliminate time spent designing the same transitions at multiple institutions, community portals have begun to host well-designed and vetted assays.(22-24) Analyzing the experimental data requires significant computational effort to align files across replicates and experimental conditions, pick peaks and produce quantitative values, normalize data and perform statistical tests, etc.(25-27)

Gibbons, Bryson C.↗