Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “heating systems”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 847 records · Page 47

Low Carbon Technology Strategies: Secondary School

This document includes steps that building owners and operators can implement to achieve smart, healthy, and low-carbon secondary schools within their existing building portfolios. Secondary schools often include complex heating and cooling systems or packaged rooftop units and can include specialty equipment for gymnasiums, pools, and buses.

analytics↗

Energy efficient supercritical water desalination using a high-temperature heat pump: A zero liquid discharge desalination

Supercritical water desalination (SCWD) is zero liquid discharge technology that can potentially control the solubility of different electrolytes. However, SCWD is an energy-intensive process and requires high-quality thermal heat (> 450 °C). This study proposes the integration of a high-temperature heat pump to reduce the SCWD energy requirement. The integrated system energy consumption improves by 36% for 3.5% feed concentration and 14% for 20% feed, and the distillate cost reduces by 15% and 10%. Another benefit of the proposed integration is the system can be operated using only electricity as a heat source, as is the case with commonly used high-recovery thermal desalination technology. The integrated SCWD-heat pump system shows superior performance compared to the commercially used brine concentrator and crystallizer system. It is approximately 20% more energy-efficient for 25% feed concentration and 8% cheaper. Hence, the integrated SCWD-heat pump has the potential to outperform the pre-existing high-recovery desalination technology.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Peak Power Minimization for Commercial Thermostatically Controlled Loads in Multi-Unit Grid-Interactive Efficient Buildings

The load profiles of most commercial and industrial consumers are characterized by brief periods of very high power consumption followed by intervals of lower demand. To encourage such consumers to flatten their load profiles, power utilities in and around the world often levy a monthly demand charge (DC) on the peak demand measured over brief intervals. In this work, we consider the joint optimization of energy costs (EC) and the instantaneous peak power of a multi-unit building which uses a hydronic heating, ventilation and cooling (HVAC) system and responds to a demand response (DR) program. Despite the non-linear structure of the problem, we show how optimal solutions can be obtained efficiently using linear programming. Next, we study the power demand patterns resulting from our proposed strategy for thermostatically controlled loads (TCLs), and evaluate the strategy’s performance for various climate zones in the US, under both typical and atypical weather conditions. Finally, the results show that depending on the ambient conditions and the tariff structure, our strategy can result in utility bill savings of up to nearly 19% compared to the baseline. The results also indicate that our power control strategy can significantly reduce the instantaneous peak power consumption in commercial TCLs.

HVAC↗

The Cost of Comfort in Your Home: Peak-Time Energy and Cost Savings from Setpoint Adjustment of Space Heating and Cooling

This poster presents the tradeoff between energy costs and thermal comfort in homes. Residential heating and cooling systems use a thermostat control to maintain a comfortable temperature range, but tighter temperature control leads to higher annual energy costs. We estimate the impact of temperature setpoint adjustment on annual energy costs using a residential building model developed at NREL. We show that increasing the allowable temperature range reduces energy costs in all five of the climate zones in the U.S. Annual costs reduced by about $100, with larger savings in areas with more heating and/or cooling loads.

30 DIRECT ENERGY CONVERSION↗

Development and Standup Testing of a System to Observe Fission Gas Release During Transient Heating of Nuclear Fuel Element Segments

As part of an effort to increase the burnup of nuclear fuels used in Light Water Reactors, the mechanisms and timing of fission gas release during high temperature transients must be studied. In this work, a system was built to observe fission gas release of fuel element sections under evacuated conditions, at temperatures up to 800 °C. System capabilities and limitations are overviewed in this report. The system was further tested with a hydrogen-infused titanium foils and gas release was observed in agreement with literature observations. Pressure was monitored with two sensors, and temperature was monitored using a thermocouple and a pyrometer with continuous visual imaging.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Measurements of the thermal conductivity of reference liquids using a modified transient hot-wire needle probe

Many power generation processes feature some type of working fluid that plays a critical role in the transfer of heat throughout the system. To optimize thermal efficiencies, an accurate characterization of the temperature-dependent thermal conductivity of the fluid is needed. Herein, this study develops a time-domain Modified Transient Hot-wire Needle Probe to overcome phenomena that have impaired traditional measurement techniques when the fluid is both corrosive and at an elevated temperature. First, the physical design of the instrument is presented to demonstrate features that limit interference from corrosion, electrical conduction, and convective and radiative heat transfer. Next, a governing equation for 1D (radial) heat conduction is fully developed using the thermal quadrupoles technique. A finite-element study is performed for validation. A sensitivity analysis is done to assess the time-dependent influence of critical parameters in the governing equation for several samples. Finally, thermal conductivity measurements are presented for seven different liquid substances by fitting the thermal model to experimental data across a range of temperatures. Reference correlations are included for comparison. The sample thermal conductivity and ambient temperature of the experimental conditions range from 0.125–16.5$\frac{W}{m·K}$ and 10–400°C, respectively. The total uncertainty, comprised of both the experimental design and fitting process, of all measurements is quantified.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Air quality and comfort constrained energy efficient operation of multi-zone buildings

Maintaining indoor air quality (IAQ) through effective ventilation is essential for the well-being and productivity of building occupants. Control strategies aimed at improving the efficiency of heating, ventilation and air conditioning (HVAC) systems must jointly determine ventilation and heating and cooling processes. Here, in this paper, we study the problem of minimizing the energy consumption of the HVAC system in a multi-zone building, while meeting thermal comfort and IAQ requirements. We first perform a steady state analysis of the zonal carbon dioxide (CO 2 ) concentration and the temperature dynamics. The resulting expressions are convex in the zonal mass flow rates and zonal temperatures. Guided by the steady state solutions for meeting the thermal comfort constraints, we develop two control policies for improving the energy efficiency of building HVAC systems while jointly satisfying indoor temperature and IAQ constraints. We compare the performance of our proposed approaches with those of multiple baseline approaches which implement separate regimes for controlling zonal temperature and IAQ for a typical work-day in a multi-zone campus building. We have evaluated the performance of our proposed approaches under varying levels of flexibility in zonal temperatures. We have shown that zonal temperature flexibility can result in energy savings up to 32% (for the same control strategies) as compared to the case where no such flexibility is permitted. Our proposed approaches were seen to offer potential savings of nearly 29% compared to the baseline.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

CO2 Profiling System for CO2 Storage (a1-level)

The Southern Great Plains (SGP) carbon dioxide flux (CO2FLUX) measurement systems provide half-hour average fluxes of CO2, H2O (latent heat), sensible heat, and momentum. The systems use the eddy covariance technique, which computes the fluxes from the vertical wind speed in combination with the concentrations of CO2 and H2O, temperature, and horizontal wind speed, respectively. A 3D sonic anemometer obtains the wind components and the temperature, while an infrared gas analyzer measures CO2 and H2O. A sub-system also measures half-hour averages of radiation, meteorological, and soil measurements.

54 ENVIRONMENTAL SCIENCES↗

Numerical Modeling & Size Optimization of Thermal Energy Storage for Iron & Steel Production

Iron and steel production are responsible for 90 million MtCO2 per year in the United States. Hydrogen direct reduction of iron (H2DRI) is a promising pathway for a more sustainable iron production than commercially deployed technologies which rely on natural gas. The H2DRI process requires hydrogen at a temperature of up to 950 degrees C fed into a reduction furnace to produce pellets or briquettes that are used in the downstream iron and steelmaking process. In this work, we propose to use an electrical thermal energy storage (ETES) system, that can use renewable electricity to store high-temperature heat and dispatch it upon demand. Such a system can buffer the H2DRI plant from the variability of electricity prices by charging during curtailment and running the plant from storage during times of peak electricity price. We have developed heat transfer models for two different ETES systems that can be used to heat up hydrogen to the required temperatures: a particle-based ETES and a firebrick ETES. These models are used to evaluate the performance of such a system and support the sizing and preliminary cost estimation. The preliminary results using both models show that designing ETES systems for an industrial-scale H2DRI furnace is feasible. The firebrick ETES system has limited operational duration, which might limit the price buffering effect unless significantly oversized. The particle ETES system heat exchanger has industry-feasible dimensions, but its storage capacity would be decided upon the number of particle storage silos.

25 ENERGY STORAGE↗

Assessment of RELAP5-3D Code with Molten Salt Heat Transfer Experiments

The accurate thermal-hydraulic assessment of thermal storage systems is crucial for addressing the integrity and performance of the storage system design. This is particularly important for thermal storage systems using molten salts as a heat transport and storage medium, as the chemical corrosion and erosion by the high-temperature molten salts can cause serious damage to the structural components of the storage system. To understand these effects for TerraPower’s Natrium® Demonstration Reactor design, the system thermal-hydraulic analysis code, RELAP5-3D, is utilized to analyze the thermal storage system. This study evaluates two heat transfer correlations implemented in the RELAP5-3D code—the Dittus-Boelter and Gnielinski correlations—using selected benchmark cases from two molten salt heat transfer experiments conducted at Xi’an Jiao Tong University and the German Aerospace Center. The Nusselt numbers calculated using the Gnielinski correlation agree with the experimental data within ±5% of the relative deviations at 300°C and 400°C. With the increasing Reynolds numbers, the Dittus-Boelter correlation underestimates the Nusselt numbers by up to 22% compared to the Gnielinski correlation. Comparison of the RELAP5-3D calculation results with experimental data at a high temperature of 550°C revealed that the thermo-chemical characteristics of solar salt at high temperatures surpassing the decomposition temperatures of nitrate salts reduce the accuracy of heat transfer model of the RELAP5-3D code. Specifically, it has been observed that the temperatures of the wall surface and liquid near the wall can surpass the decomposition temperatures, even though the bulk temperature of molten salts remains significantly lower than these decomposition temperatures. In summary, this study recommends the use of the Gnielinski correlation for the heat transfer analysis of molten salt, rather than the Dittus-Boelter correlation.

21 - SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLAN↗

Accuracy of HVAC Load Predictions: Validation of EnergyPlus and DOE-2 using FLEXLAB Measurements

The aim of the project reported here was to better understand the level of accuracy of three building energy simulation (BES) engines (‘engines’) — EnergyPlus™, DOE-2.1e, and DOE-2.2 — by identifying and investigating significant deviations between the performance predicted by these engines and actual performance as measured in the FLEXLAB® test facility at Lawrence Berkeley National Laboratory (LBNL). The specific test conditions included some of those prescribed in ANSI/ASHRAE Standard 140 - Standard Method of Test for the Evaluation of Building Energy Analysis Computer Programs. Detailed measurements of FLEXLAB performance, including indoor temperatures and heat fluxes and air-flow and water flow rates and temperatures in the Heating, Ventilating and Air Conditioning (HVAC) system, together with hourly weather data, were recorded and used in analyzing the simulation results from EnergyPlus v8.8, DOE-2.2 v3.65 and DOE-2.1e v127. These engines are commonly used in the United States for building energy code compliance, federal, state, and utility incentives programs, as well as energy efficient design of new buildings and energy retrofit of existing buildings. Seven conventional overhead mixing ventilation scenarios were tested and each engine was found to have a similar level of agreement with the measurements of space-level heating and sensible cooling loads. These results provide useful information regarding the accuracy of these engines in predicting the cooling and heating load elements of whole building energy performance. This information is intended for practitioners who are concerned about transitioning between simulation tools with different engines and for managers of utility programs leveraging these tools for evaluating and/or projecting measure savings to be incentivized under their programs. The results of the comparisons of simulated and measured performance indicate that the predictions from all three engines are not significantly different. The 24-hour average value of the absolute mean bias indicates the likely magnitude of the error in any particular case. The average mean bias is reduced by cancelation of overprediction in one case by underprediction in another. The daytime absolute mean biases, which may be more important for both energy performance and occupant comfort, are ~6%, presumably because of the greater complexity involved in simulating in the presence of solar radiation. EnergyPlus typically overpredicts the cooling load and/or underpredicts the heating load by ~1.5% and the DOE-2 engines typically underpredict the cooling load by approximately the same amount. The Root Mean Square Error is relatively more sensitive to shorter term variations in the difference between predicted and measured loads; the three engines have similar values, ~10%, suggesting that the uncertainties in their predictions of peak loads may also be similar in magnitude. The implication of these results is that users, both designers and program analysts, can use EnergyPlus, DOE-2.1e, or DOE-2.2 to model conventional commercial buildings equipped with overhead mixing ventilation with a similar level of confidence. Further work is required to better understand the variability in the level of agreement between the engine predictions and FLEXLAB measurements, where a particular engine will agree well with FLEXLAB in some cases and not so well in others and another engine will agree or disagree in different cases. As the sources of this variability are identified and eliminated or reduced significantly, it is recommended that the experimental capabilities and methods developed in the study reported here should be applied to validating heating and cooling load calculations for spaces with different types of furniture and miscellaneous loads. These methods should then be applied to low energy space conditioning systems in EnergyPlus including, in particular, radiant slab and radiant ceiling panel cooling and heating systems and ‘mixed mode’ systems that combine mechanical cooling and natural ventilation systems, focusing on controls, including control of thermal mass. The work reported here addresses the conventional method of heating and cooling occupied spaces; other methods, such as the use of radiant heating and cooling systems have the potential to provide equivalent occupant comfort, or better, with lower energy consumption. These systems are addressed more explicitly in EnergyPlus but there is a need for empirical validation to give users the same level of confidence in modeling these systems that they have, or should have, in modeling conventional systems, based on the results presented here.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

PANDEMIC: Occupancy driven predictive ventilation control to minimize energy consumption and infection risk

During the SARS-CoV-2 (COVID-19) pandemic, governments around the world have formulated policies requiring ventilation systems to operate at a higher outdoor fresh air flow rate for a sufficient time, which has led to a sharp increase in building energy consumption. Therefore, it is necessary to identify an energy-efficient ventilation strategy to reduce the risk of infection. In this study, we developed an occupant-number-based model predictive control (OBMPC) algorithm for building ventilation systems. First, we collected the occupancy and Heating, ventilation, and air conditioning system (HVAC) data from March to July 2021. Then, four different models (Auto regression moving average-based multilayer perceptron (ARMA_MLP), Recurrent neural networks (RNN), Long short-term memory networks (LSTM), and Nonhomogeneous Markov with change points detection (NH_Markov)) were used to predict the number of room occupants from 15 min to 24 h ahead with an interval output. We found that each model could predict the number of occupants with 85% accuracy using a one-person offset. Furthermore, the accuracy of 15 min of the ahead prediction could reach 95% with a one-person offset, but none of them could track abrupt changes. The occupancy prediction results were used to calculate the ventilation demand using the Wells-Riley equation, and the upper bound can maintain an infection risk lower than 2% for 93% of the day. This OBMPC model could reduce the coil load by 52.44% and shift the peak load by 3 h up to 5 kW compared with 24 × 7 h full outdoor air (OA) system when people wear masks in the space. The occupancy prediction uncertainty could cause a 9% to 26% difference in demand ventilation, a 0.3°C to 2.4°C difference in zone temperature, a 28.5% to 44.5% difference in outdoor airflow rate, and a 10.7% to 28.2% difference in coil load.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Experimental Testing of Particle Erosion and Attrition in CSP Systems

In CSP systems using solid particles for heat transfer, erosion from the falling particles can damage the system components upon impact, and from sliding against the component walls. Furthermore, the resulting attrition of particles can change the thermal performance due to alterations in particle morphology. The research on these issues has been limited to industrial applications, and don’t necessarily coincide with the operating conditions in CSP systems. In this work, we investigated the durability of the particles selected as the heat transfer media, as well as special substrate materials that are of interest as lining materials to the particle storage tanks and hoppers. Three different erosion phenomena were studied: impact, abrasion, and attrition erosion. The low-temperature experiments revealed negligible losses from attrition and abrasion erosion. Although the substrates indicated visible surface damage from impact erosion, the actual material mass loss was small even after a throughput of 500kg of particles 63 days of 1MW CSP plant operation assuming 14 hours per day of operation. Erosion is typically classified as impact, abrasion, or attrition erosion. For example, the CSP systems utilizing solid particles as heat transfer media will likely experience impact erosion on the receiver hopper and heat exchanger walls as the solid particles fall from the reservoir. Additionally, there will be sliding erosion along the receiver walls as particles move through the hopper, and lastly, there will also be attrition erosion as the particles rub against each other. The extent of erosion depends on many factors including but not limited to particle shape and size, material hardness/brittleness and ductility, and particle impact speed and angle. Mechanistic erosion equations that are available in the literature are mostly derived from data pertaining to specific experiments and therefore can’t be applied to all applications without suitable adjustments. Survey of the literature relating to particle-based receivers revealed that the most prevalent approach has been to choose low velocities to limit erosion, but to our knowledge, little effort has been put in to fully characterize erosion at the expected operating conditions. A relatively recent work investigated the erosion of wire mesh proposed for use in a particle receiver, where the results actually showed an increase in mass as oxidation occurred on the mesh surface but the work did not investigate the particle attrition rate, and the erosion rate of a solid substrate. The end goal of this work is to develop a comprehensive particle and substrate durability model that will allow a comprehensive understanding of particle-based CSP operating conditions on component durability.

14 SOLAR ENERGY↗

Installation Quality Framework: Investment Return Approach for Energy Savings on Building Product Installation

A case study was conducted on 44 residential homes using both traditional house wrap and ZIP System systems to measure the overall airtightness and compare estimated energy usages. The labor, material, and overhead and profit (O&P) costs were analyzed and used to determine the optimal choice for long-term benefits in terms of cost and performance. The impact of insulation installation is considered a key factor in improving the strategy of reducing energy consumption. Improved installation practices can affect the airtightness of common wall assemblies to reduce the building energy performance gaps and provide insight on how to allocate resources better. A framework was developed to analyze operational costs and building energy performance to address how installation quality is a factor in the return of investment in building construction for heating and cooling systems within the thermal envelope. With this methodology, aggressive energy performance goals will be met while balancing the tradeoff between installation techniques and building systems efficiency based on the introduced probabilistic investment return (PIR) metric.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Unique safety features and licensing requirements of the NuScale small modular reactor

Small modular reactors (SMR) offer a novel approach to the construction and operation of nuclear power plants. The NuScale VOYGR™ plant uses a simplified SMR design that is based on proven light-water reactor technology with substantial improvements in nuclear safety. It consists of a 250 MWt reactor core housed with other primary system components in an integral reactor pressure vessel surrounded by a steel containment vessel, all of which is immersed in a large pool of water that also serves as the ultimate heat sink. At the core of the NuScale safety case are three primary safety systems: the decay heat removal system, the emergency core cooling system, and the containment. The ability of the NuScale Power Module (NPM) passive safety systems to remove core decay heat for an unlimited duration is demonstrated through analysis of a beyond-design-basis extended loss of AC power with no replenishment of water to the ultimate heat sink or operator actions. The NuScale methodology to evaluate an indefinite loss of AC power uses the proprietary NRELAP5 systems analysis computer code. Analysis results show that the reactor coolant system liquid level above the core is maintained and that containment pressure remains below the vessel design pressure. Once full passive air cooling is established, containment pressure and temperature will decrease over time with decreasing core decay heat. NuScale received standard design approval in September 2020 and design certification in January 2023 for its 50 MWe NPM configured as a 12 module plant. NuScale is currently seeking standard design approval to increase its core power to 250 MWt, nominally 77 MWe per module, in a 6-module plant (VOYGR™-6) configuration. The high-level safety of NuScale’s SMR technology is foundational to a new standard of nuclear power plant resilience.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Nuclear-Driven Integrated Energy Systems: A State-of-the-Art Review

Because of the growing concerns regarding climate change and energy sustainability, a transition toward a modern energy sector that reduces environmental effects while promoting social and economic growth has gained traction in recent years. Sustainable energy solutions, which include renewable and low-carbon sources such as nuclear energy and natural gas, could minimize emissions of greenhouse gases, enhance air and water quality, and encourage energy independence. Yet, the shift to a sustainable energy industry is fraught with difficulties, including governmental and regulatory obstacles, technological and economic limits, and societal acceptability hurdles. Addressing these issues would necessitate the development of long-term, durable, and cost-effective energy systems containing nuclear energy and associated with the generation of both electricity and other by-products required by industry. Integrated energy systems (IES) are a novel way to maximize the use of various energy resources and technologies in order to deliver dependable, efficient, and sustainable energy services. IES entail the integration of various energy systems, such as electricity, heating, cooling, and transportation, in respect to energy sustainability and a system’s resilience and flexibility. Their development and implementation require the cooperation of several parties, including energy providers and policymakers. This study provides a state-of-the-art literature review of the most creative nuclear-driven hybrid energy system applications and methodologies, from which the research challenges and prospects for effective IES implementation emerge.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗