Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “heating”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 847 records · Page 47

Distinctive Pattern of Global Warming in Ocean Heat Content

Abstract Huge heat anomalies in the atmosphere and ocean in recent years are not yet explained. Strong characteristic patterns in temperatures for upper layers of the ocean occurred from 2000 to 2023 in the presence of global warming from increasing atmospheric greenhouse gases. Here, we show that the deep tropics are warming, although sharply modulated by El Niño–Southern Oscillation events, with strong heating in the extratropics near 40°N and 40°–45°S but little heating near 20°N and 25°–30°S. The heating is most clearly manifested in zonal-mean ocean heat content and is evident in sea surface temperatures. The strongest heating is in the Southern Hemisphere, where aerosol effects are small. Estimates are made of the contributions to heating of top-of-atmosphere (TOA) radiation, atmospheric energy transports, surface fluxes of energy, and redistribution of energy by surface winds and ocean currents. The patterns of change are not directly related to TOA radiation but are evident in net surface energy fluxes and inferred ocean heat transports, underscoring their coupled origin. Changes in the atmospheric circulation through a poleward shift in ocean jet streams and storm tracks are reflected in surface wind-driven ocean Ekman transports. As well as human-induced climate change, internal natural variability is likely in play. Hence, the atmosphere and ocean currents are systematically redistributing heat from global warming, profoundly affecting local climates. Significance Statement As the climate changes, it has been difficult to discern meaningful patterns. Distinctive patterns of change have occurred in the ocean when examined as zonal averages around latitude bands. Most excess heat from global warming resides in the ocean and, since 2005, has become focused into bands near 40°N and 40°S, with little net warming in the subtropics. The strongest warming is in the Southern Hemisphere, although sea surface temperatures have increased more in the Northern Hemisphere. Changes in the atmospheric circulation through a poleward shift in the jet stream and storm tracks are primarily responsible along with corresponding changes in ocean currents. These changes are linked through surface exchanges of energy via heat, moisture, and wind stress.

Trenberth, Kevin E. [National Center for Atmospher↗

Developing affordable and efficient heating devices for enhanced live cell imaging in confocal microscopy

Temperature control is crucial for live cell imaging, particularly in studies involving plant responses to high ambient temperatures and thermal stress. This study presents the design, development, and testing of two cost-effective heating devices tailored for confocal microscopy applications: an aluminum heat plate and a wireless mini-heater. The aluminum heat plate, engineered to integrate seamlessly with the standard 160 mm × 110 mm microscope stage, supports temperatures up to 36°C, suitable for studies in the range of non-stressful warm temperatures (e.g., 25-27°C forArabidopsis thaliana) and moderate heat stress (e.g., 30-36°C forA. thaliana). We also developed a wireless mini-heater that offers rapid, precise heating directly at the sample slide, with a temperature increase rate over 30 times faster than the heat plate. The wireless heater effectively maintained target temperatures up to 50°C, ideal for investigating severe heat stress and heat shock responses in plants. Both devices performed well in controlled studies, including the real-time analysis of heat shock protein accumulation and stress granule formation inA. thaliana. Our designs are effective and affordable, with total construction costs lower than $300. This accessibility makes them particularly valuable for small laboratories with limited funding. Future improvements could include enhanced heat uniformity, humidity control to mitigate evaporation, and more robust thermal management to minimize focus drift during extended imaging sessions. These modifications would further solidify the utility of our heating devices in live cell imaging, offering researchers reliable, budget-friendly tools for exploring plant thermal biology.

Plant Sciences↗

DOE Cold Climate Heat Pump Challenge: Development, Metrics, and Early Field Observations

Space heating in residential buildings is a major contributor of Greenhouse Gas (GHG) emissions in the United States. New, advanced electric heat pumps are poised to provide a low carbon alternative to traditional fossil-based heating, especially in colder climates. Widespread deployment of cold climate heat pumps could help address the significant portion of building emissions and primary energy used in American households, but these gains will require broader acceptance from consumers and decision makers. As part of the “Energy, Emissions, and Equity” (E3) initiative, the U.S. Department of Energy launched the Cold Climate Heat Pump Challenge (CCHP) in 2021 to accelerate the deployment of the next generation of air source heat pumps. The Challenge is currently focused on residential, centrally ducted, electric heat pumps, with a nominal cooling capacity greater than or equal to 24,000 Btu/h (2 tons) and less than or equal to 65,000 Btu/h (5 tons). The Challenge specifications represent a best-in-class heat pump product that provides high-efficiency heating performance in cold climates, employs environmentally friendly low-Global Warming Potential (GWP) refrigerants, and is designed to be grid interactive. Spearheaded by DOE in partnership with the US Environmental Protection Agency (EPA) and Natural Resources Canada (NRCan), the CCHP Challenge brings together numerous major heat pump manufacturers and key stakeholders including utilities and state agencies across the country. In addition to performance testing in a laboratory environment, a key component of this research is evaluating the in-field performance of the prototype heat pumps developed as part of the Challenge. This paper will discuss the development of the CCHP Challenge, key performance specifications, and the energy and non-energy metrics that will be evaluated through the field study. The types of data that are being collected from the units installed in homes across North America as part of the field validation will be described, including details about the sensors and data acquisition system. Data cleaning and analysis methodologies will be discussed, along with early observations from the winter 2022-2023, spring and summer performance periods, and an assessment of non-energy metrics through pre- and post-installation homeowner surveys. Challenges uncovered and lessons learned throughout the process will also be discussed. Finally, the paper will discuss next steps for the second winter assessment period, areas needing additional research, and potential applications of the data collected and analyzed through this work.

Mendon, Vrushali V.↗

Study of fuel cell powerplant with heat recovery

It was shown that heat can be recovered from fuel cell power plants by replacing the air-cooled heat exchangers in present designs with units which transfer the heat to the integrated utility system. Energy availability for a 40-kW power plant was studied and showed that the total usable energy at rated power represents 84 percent of the fuel lower heating value. The effects of design variables on heat availability proved to be small. Design requirements were established for the heat recovery heat exchangers, including measurement of the characteristics of two candidate fuel cell coolants after exposure to fuel cell operating conditions. A heat exchanger test program was defined to assess fouling and other characteristics of fuel cell heat exchangers needed to confirm heat exchanger designs for heat recovery.

King, J. M.↗

Heat pipes in space and on earth

The heat pipe is a closed tube whose inner surfaces are lined with a porous capillary wick. The wick is saturated with the liquid phase of a working fluid. The heat supplied at one end of the tube, the evaporator, causes evaporation of the working fluid. The vapor will pass to the other end of the tube, the condenser, where it will condense and release the latent heat of vaporization to a heat sink in that section of the pipe. Problems concerning a design of heat pipes for space applications are related to certain difficulties regarding the prediction of device performance under zero-g conditions. Heat pipes are usually tested on the ground under the influence of gravity, and then their performance is extrapolated to space. A description is presented of the approaches used to insure good heat pipe performance in space. Attention is given to an international heat pipe experiment conducted to accumulate zero-g performance data for several new and unique heat pipe designs, heat pipes for ATS-6, cryogenic heat pipes, and future activities.

Ollendorf, S.↗

Investigation of Effectiveness of Air-Heating a Hollow Steel Propeller for Protection Against Icing. 3: 25% Partitioned Blades

The icing protection obtained from an internally air-heated propeller blade partitioned to confine the heated air forward of 25-percent chord was investigated in the NACA Cleveland icing research tunnel. A production-model hollow steel propeller was modified with an Internal radial partition at 25-percent chord and with shank and tip openings to admit and exhaust the heated air. Temperatures were measured on the blade surfaces and in the heated-air system during tunnel icing conditions. Heat-exchanger effectiveness and photographs of Ice formations on the blades were obtained. Surface temperature measurements indicated that confining the heated air forward of the 25-percent chord gave.a more economical distribution of the applied heat as compared with unpartitioned and 50-percent partitioned blades, by dissipating a greater percentage of the available heat at the leading edge. At a propeller speed of 850 rpm, a heating rate of 7000 Btu per hour per blade at a shank air temperature of 400 F provided adequate Icing protection at ambient-air temperatures of 23 F but not at temperatures as low as 15 F. With the heating rate used, a heat-exchanger effectiveness of 77 percent was obtained as compared to 56 percent for 50-percent partitioned and 47 percent for unpartitioned blades.

Mulholland, Donald R.↗

Experiments on fuel heating for commercial aircraft

An experimental jet fuel with a -33 C freezing point was chilled in a wing tank simulator with superimposed fuel heating to improve low temperature flowability. Heating consisted of circulating a portion of the fuel to an external heat exchanger and returning the heated fuel to the tank. Flowability was determined by the mass percent of unpumpable fuel (holdup) left in the simulator upon withdrawal of fuel at the conclusion of testing. The study demonstrated that fuel heating is feasible and improves flowability as compared to that of baseline, unheated tests. Delayed heating with initiation when the fuel reaches a prescribed low temperature limit, showed promise of being more efficient than continuous heating. Regardless of the mode or rate of heating, complete flowability (zero holdup) could not be restored by fuel heating. The severe, extreme-day environment imposed by the test caused a very small amount of subfreezing fuel to be retained near the tank surfaces even at high rates of heating. Correlations of flowability established for unheated fuel tests also could be applied to the heated test results if based on boundary-layer temperature or a solid index (subfreezing point) characteristic of the fuel.

Friedman, R.↗

Heating experiments for flowability improvement of near-freezing aviation fuel

An experimental jet fuel with a -33 C freezing point was chilled in a wing tank simulator with superimposed fuel heating to improve low temperature flowability. Heating consisted of circulating a portion of the fuel to an external heat exchanger and returning the heated fuel to the tank. Flowability was determined by the mass percent of unpumpable fuel (holdup) left in the simulator upon withdrawal of fuel at the conclusion of testing. The study demonstrated that fuel heating is feasible and improves flowability as compared to that of baseline, unheated tests. Delayed heating with initiation when the fuel reaches a prescribed low temperature limit, showed promise of being more efficient than continuous heating. Regardless of the mode or rate of heating, complete flowability (zero holdup) could not be restored by fuel heating. The severe, extreme-day environment imposed by the test caused a very small amount of subfreezing fuel to be retained near the tank surfaces even at high rates of heating. Correlations of flowability established for unheated fuel tests also could be applied to the heated test results if based on boundary-layer temperature or a solid index (subfreezing point) characteristic of the fuel. Previously announced in STAR as N82-26483

Friedman, R.↗

Development of an integrated heat pipe-thermal storage system for a solar receiver

An integrated heat pipe-thermal storage system was developed as part of the Organic Rankine Cycle Solar Dynamic Power System solar receiver for space station application. The solar receiver incorporates potassium heat pipe elements to absorb and transfer the solar energy within the receiver cavity. The heat pipes contain thermal energy storage (TES) canisters within the vapor space with a toluene heater tube used as the condenser region of the heat pipe. During the insolation period of the earth orbit, solar energy is delivered to the heat pipe. Part of this thermal energy is delivered to the heater tube and the balance is stored in the TES units. During the eclipse period of earth orbit, the stored energy in the TES units is transferred by the potassium vapor to the toluene heater tube. A developmental heat pipe element was constructed that contains axial arteries and a distribution wick connecting the toluene heater and the TES units to the solar insolation surface of the heat pipe. Tests were conducted to demonstrate the heat pipe, TES units, and the heater tube operation. The heat pipe element was operated at design input power of 4.8 kW. Thermal cycle tests were conducted to demonstrate the successful charge and discharge of the TES units. Axial power flux levels up to 15 watts/sq cm were demonstrated and transient tests were conducted on the heat pipe element. Details of the heat pipe development and test procedures are presented.

Keddy, E.↗

Capillary-Condenser-Pumped Heat-Transfer Loop

Heat being transferred supplies operating power. Capillary-condenser-pumped heat-transfer loop similar to heat pipe and to capillary-evaporator-pumped heat-transfer loop in that heat-transfer fluid pumped by evaporation and condensation of fluid at heat source and sink, respectively. Capillary condenser pump combined with capillary evaporator pump to form heat exchanger circulating heat-transfer fluids in both loops. Transport of heat more nearly isothermal. Thermal stress in loop reduced, and less external surface area needed in condenser section for rejection of heat to heat sink.

Silverstein, Calvin C.↗

Influence of heating mode on three-dimensional mantle convection

Numerical models of three-dimensional thermal convection in highly viscous spherical shells with different combinations of internal and basal heating consistently have upwelling concentrations in the form of cylindrical plumes and downwelling in planar sheets. As the proportion of internal heating increases, the number of upwelling plumes increases, and downwelling sheets become more vigorous and time-dependent. With any amount of basal heating, the entire convective pattern, during its evolution, is anchored to the upwelling plumes. As the proportion of internal heating increases, the heat flow carried by the upwelling plumes remains a large fraction of the basal heat flow. Downwelling sheets carry only a minor fraction (approximately 30 percent) of the basal heat flow (even when the shell is entirely heated from below), but they advect almost all of the internally generated heat. The relatively large number of plumes in the earth's mantle (inferred from hotspots), the possibility that downwelling slabs are vigorous enough to penetrate the lower mantle, and the small fraction of terrestrial surface heat flow carried by plumes all suggest that the mantle is predominantly heated from within.

Bercovici, D.↗

Aerodynamic pressure and heating-rate distributions in tile gaps around chine regions with pressure gradients at a Mach number of 6.6

Surface and gap pressures and heating-rate distributions were obtained for simulated Thermal Protection System (TPS) tile arrays on the curved surface test apparatus of the Langley 8-Foot High Temperature Tunnel at Mach 6.6. The results indicated that the chine gap pressures varied inversely with gap width because larger gap widths allowed greater venting from the gap to the lower model side pressures. Lower gap pressures caused greater flow ingress from the surface and increased gap heating. Generally, gap heating was greater in the longitudinal gaps than in the circumferential gaps. Gap heating decreased with increasing gap depth. Circumferential gap heating at the mid-depth was generally less than about 10 percent of the external surface value. Gap heating was most severe at local T-gap junctions and tile-to-tile forward-facing steps that caused the greatest heating from flow impingement. The use of flow stoppers at discrete locations reduced heating from flow impingement. The use of flow stoppers at discrete locations reduced heating in most gaps but increased heating in others. Limited use of flow stoppers or gap filler in longitudinal gaps could reduce gap heating in open circumferential gaps in regions of high surface pressure gradients.

Hunt, L. Roane↗

Heat pipe radiation cooling of advanced hypersonic propulsion system components

Heat transfer, heat pipe, and system studies were performed to assess the newly proposed heat pipe radiation cooling (HPRC) concept. With an HPRC system, heat is removed from the ramburner and nozzle of a hypersonic aircraft engine by a surrounding, high-temperature, heat pipe nacelle structure, transported to nearby external surfaces, and rejected to the environment by thermal radiation. With HPRC, the Mach number range available for using hydrocarbon fuels for aircraft operation extends into the Mach 4 to Mach 6 range, up from the current limit of about Mach 4. Heat transfer studies using a newly developed HPRC computer code determine cooling system and ramburner and nozzle temperatures, heat loads, and weights for a representative combined-cycle engine cruising at Mach 5 at 80,000 ft altitude. Heat pipe heat transport calculations, using the Los Alamos code HTPIPE, reveal that adequate heat trasport capability is available using molybdenum-lithium heat pipe technology. Results show that the HPRC system radiator area is limited in size to the ramburner-nozzle region of the engine nacelle; reasonable system weights are expected; hot section temperatures are consistent with advanced structural materials development goals; and system impact on engine performance is minimal.

Martin, R. A.↗

Transient response of a high-capacity heat pipe for Space Station Freedom

High-capacity heat pipe radiator panels have been proposed as the primary means of heat rejection for Space Station Freedom. In this system, the heat pipe would interface with the thermal bus condensers. Changes in system heat load can produce large temperature and heat load variations in individual heat pipes. Heat pipes could be required to start from an initially cold state, with heat loads temporarily exceeding their low-temperature transport capacity. The present research was motivated by the need for accurate prediction of such transient operating conditions. In this work, the cold startup of a 6.7-meter long high-capacity heat pipe is investigated experimentally and analytically. A transient thermohydraulic model of the heat pipe was developed which allows simulation of partially-primed operation. The results of cold startup tests using both constant temperature and constant heat flux evaporator boundary conditions are shown to be in good agreement with predicted transient response.

Ambrose, J. H.↗

Analytical and experimental studies of heat pipe radiation cooling of hypersonic propulsion systems

Analytical and experimental studies were completed to assess the feasibility of using high-temperature heat pipes to cool hypersonic engine components. This new approach involves using heat pipes to transport heat away from the combustor, nozzle, or inlet regions, and to reject it to the environment by thermal radiation from an external heat pipe nacelle. For propulsion systems using heat pipe radiation cooling (HPRC), it is possible to continue to use hydrocarbon fuels into the Mach 4 to Mach 6 speed range, thereby enhancing the economic attractiveness of commercial or military hypersonic flight. In the second-phase feasibility program recently completed, it is found that heat loads produced by considering both convection and radiation heat transfer from the combustion gas can be handled with HPRC design modifications. The application of thermal insulation to ramburner and nozzle walls was also found to reduce the heat load by about one-half and to reduce peak HPRC system temperatures to below 2700 F. In addition, the operation of HPRC at cruise conditions of around Mach 4.5 and at an altitude of 90,000 ft lowers the peak hot-section temperatures to around 2800 F. An HPRC heat pipe was successfully fabricated and tested at Mach 5 conditions of heat flux, heat load, and temperature.

Martin, R. A.↗

The vertical structure of diabatic heating associated with the Madden-Julian oscillation simulated by the Goddard Laboratory for Atmospheres climate model

The diabatic heating structure of the nine-layer Goddard Laboratory for Atmospheres model of the Madden-Julian oscillation (MJO) is illustrated with composite charts made for those times when this low-frequency mode reaches its maximum and minimum amplitudes. These composite charts compare the vertically integrated diabatic heating with potential functions, the vertical distribution of diabatic heating with the east-west mass flux function in the tropics, and the vertical profiles of diabatic heating at the centers of maximum and minimum MJO amplitude. Three interesting features of the model MJO's diabatic heating are revealed: (1) the maximum heating rate of this low-frequency mode is located over the Asian monsoon region and its amplitude is about a half of the maximum value of the seasonal mean heating rate in this region, (2) the vertical diabatic heating rate profile has a maximum at 500 mbar and resembles the seasonal mean total heating profile, and (3) the total diabatic heating is for the most part composed of the latent heat released by cumulus convection.

Chen, Tsing-Chang↗

Vaporization heat transfer of dielectric liquids on enhanced surfaces covered with screen wicks

Experiments were conducted to investigate the vaporization heat transfer characteristics for the dielectric liquid FC-72 on several wicking surfaces which may be used in flat-plate heat pipes. The wicking materials studied included microstructure enhanced surfaces and coarse surfaces covered with screen meshes. Experimental data for q versus deltaT curves and critical heat fluxes were obtained for the two different operating conditions of a heat pipe, evaporation, and shallow pool boiling. When the liquid level was above the heated surface, the height of the liquid level above the surface was varied from 0 to 10 mm. When the liquid level was below the heated surface, the distance from the liquid level to the edge of the surface was adjusted from 0 to 15 mm. Experimental results revealed that for shallow pool boiling when the heated surface was covered with a wire screen mesh, the heat transfer coefficient increased at lower heat fluxes but the critical heat flux (CHF) decreased for all the surfaces tested. In the case of evaporation, both CHF and the heat transfer coefficient increased as the microstructure surfaces were covered with screen meshes.

Gu, C. B.↗

Heat flux measurements on ceramics with thin film thermocouples

Two methods were devised to measure heat flux through a thick ceramic using thin film thermocouples. The thermocouples were deposited on the front and back face of a flat ceramic substrate. The heat flux was applied to the front surface of the ceramic using an arc lamp Heat Flux Calibration Facility. Silicon nitride and mullite ceramics were used; two thicknesses of each material was tested, with ceramic temperatures to 1500 C. Heat flux ranged from 0.05-2.5 MW/m2(sup 2). One method for heat flux determination used an approximation technique to calculate instantaneous values of heat flux vs time; the other method used an extrapolation technique to determine the steady state heat flux from a record of transient data. Neither method measures heat flux in real time but the techniques may easily be adapted for quasi-real time measurement. In cases where a significant portion of the transient heat flux data is available, the calculated transient heat flux is seen to approach the extrapolated steady state heat flux value as expected.

Holanda, Raymond↗