An Overview of Behind-the-Meter Solar-Plus-Storage Regulatory Design: Approaches and Case Studies to Inform International Applications

Behind-the-meter energy storage systems paired with distributed photovoltaic (DPV) - with the capability to act as both generation and load - represent a unique and disruptive power sector technology capable of providing a range of important services to customers, utilities, and the broader power system. How should regulators, utilities, and policymakers manage the range of challenges and opportunities that increased behind-the-meter energy storage deployment will bring to the power system, in particular when these systems are paired with DPV? This report is intended to offer key regulatory considerations for facilitating DPV-plus-storage programs for retail customers; relevant cases from U.S. states are provided as examples of how novel regulatory issues related to behind-the-meter energy storage systems paired with DPV are being addressed in practice. At a high level, designing a regulatory framework that aligns DPV-plus-storage deployment with larger policy objectives requires thoughtful deliberation across a range of technical and economic issues. While this report attempts to segment many of these issues into distinct topics to enhance reader understanding, in reality, DPV-plus-storage regulatory issues are all closely integrated, and design decisions on a single aspect often have broader implications. With that in mind, this report outlines a series of steps that can be employed by regulators to approach DPV-plus-storage regulatory design.

14 SOLAR ENERGY↗

Impacts of Renewable Energy and Green Hydrogen Policies on Uttar Pradesh's Power Sector Future: Additional Modeling Scenarios to Explore Hydrogen Flexibility [Slides]

This slide deck is part of a broader program focused on supporting Indian states with long-term power system planning. More information about this program can be found at the National Renewable Energy Laboratory's "Supporting India's States With Renewable Energy Integration" web page at https://www.nrel.gov/international/india-renewable-energy-integration.html. The power sector in Uttar Pradesh, India's most populous state, is poised to transform over the next few decades due to a combination of national and state-level policies impacting both the supply and demand of electricity. The Government of Uttar Pradesh has policies and plans to develop in-state solar PV, pumped storage hydropower, and green hydrogen. Power system policymakers and utilities in Uttar Pradesh are faced with the challenges of planning a system that incorporates increasing amounts of renewable energy and storage resources, meets rising electricity demand due to economic development and green hydrogen production, and satisfies operational and reliability requirements. To support these various objectives, the National Renewable Energy Laboratory (NREL), RMI, and the Uttar Pradesh New and Renewable Energy Development Agency (UPNEDA) evaluated the least-cost pathways for the state's power sector through 2050. NREL developed a capacity expansion model that identifies investment and operational decisions for every year (2024-2050) for all of India, with detailed representation for the state of Uttar Pradesh, which can provide a framework for recurring planning studies. The purpose of this slide deck is to supplement the main study (published in May 2024) with additional modeling scenarios to explore hydrogen flexibility.

08 HYDROGEN↗

Quantifying the effects of varietal types × management on the spatial variability of sorghum biomass across US environments

Abstract Regional‐scale estimations of sorghum biomass production allow identification of optimum genotype×environment×management (G×E×M) combinations for bioenergy generation. The objective of this study was to determine the degree of contributions of G, E, and M toward variability in sorghum biomass in the United States. Using the Agricultural Production Systems sIMulator in a grid computing platform, biomass was simulated for irrigated and rainfed conditions for 30 years across the United States for four sorghum varietal types (grain—GS, sudangrass—SS, photosensitive—PS, and photo‐insensitive—PI). Simulated biomass was assessed by environments clustered using the sum of intercepted solar radiation ( ir ), mean of temperature stress factor ( tp ) and water stress factor ( sw ). Simulated biomass ranged from 5.8 t ha −1 (GS‐rainfed) to 27.5 t ha −1 (PI‐irrigated). Under high‐temperature environments (mean annual temperature = 25°C), rainfed biomass between 40 and 80 days after planting (DAP) was strongly correlated with sw ( r = 0.64–0.86) and irrigated biomass with ir ( r = 0.68–0.81). Under low‐temperature environments (mean annual temperature = 18°C) after 40 DAP, tp and ir had greater effects than sw ( r = 0.55–0.82). Biomass variance was mainly explained by varietal type (50%–76%) in all environments×irrigation combinations, except in the high‐ and mid‐temperature environments under rainfed conditions where rainfall had the major effect (25%–45%). However, when mean temperature during the growing season decreased from 25°C (high environments) to 18°C (low environments), the contribution of mean temperature to biomass variance increased from 7% to 34% (rainfed) and from 4% to 36% (irrigated). Varietal type had the larger interactions with other factors independently of the environment and irrigation. We demonstrated a need to quantify (i) the main G×E×M drivers of biomass variability based on environmental stress factors and (ii) the variance contribution of these drivers on sorghum biomass. Our regional‐scale estimations are key inputs for future robust biomass projections of energy sorghum genotypes integrating G×E×M under climate change scenarios.

Ojeda, Jonathan J.↗

Balancing renewable energy and river resources by moving from individual assessments of hydropower projects to energy system planning

As governments and non-state actors strive to minimize global warming, a primary strategy is the decarbonization of power systems which will require a massive increase in renewable electricity generation. Leading energy agencies forecast a doubling of global hydropower capacity as part of that necessary expansion of renewables. While hydropower provides generally low-carbon generation and can integrate variable renewables, such as wind and solar, into electrical grids, hydropower dams are one of the primary reasons that only one-third of the world’s major rivers remain free-flowing. This loss of free-flowing rivers has contributed to dramatic declines of migratory fish and sediment delivery to agriculturally productive deltas. Further, the reservoirs behind dams have displaced tens of millions of people. Thus, hydropower challenges the world’s efforts to meet climate targets while simultaneously achieving other Sustainable Development Goals. In this paper, we explore strategies to achieve the needed renewable energy expansion while sustaining the diverse social and environmental benefits of rivers. These strategies can be implemented at scales ranging from the individual project (environmental flows, fish passage and other site-level mitigation) to hydropower cascades to river basins and regional electrical power systems. While we review evidence that project-level management and mitigation can reduce environmental and social costs, we posit that the most effective scale for finding balanced solutions occurs at the scale of power systems. We further hypothesize that the pursuit of solutions at the system scale can also provide benefits for investors, developers and governments; evidence of benefits to these actors will be necessary for achieving broad uptake of the approaches described in this paper. We test this hypothesis through cases from Chile and Uganda that demonstrate the potential for system-scale power planning to allow countries to meet low-carbon energy targets with power systems that avoid damming high priority rivers (e.g., those that would cause conflicts with other social and environmental benefits) for a similar system cost as status quo approaches. We also show that, through reduction of risk and potential conflict, strategic planning of hydropower site selection can improve financial performance for investors and developers, with a case study from Colombia.

Opperman, Jeffrey J.↗

A Generic and Multifunctional Electromagnetic Transient Model for Grid-Following Inverters

This paper presents a generic and multifunctional electromagnetic transient (EMT) dynamic model of grid-following (GFL) inverter-based resources (IBRs) using the PSCAD software platform. The features of the model include flexibility in selecting various types and combinations of DC sources covering photovoltaic modules, battery modules, and ideal DC-source modules as well as flexibility in selecting either switching or averaged models of the inverter. This model also covers exhaustive lists of controller algorithm, including open-loop/closed-loop PQ dispatch control, DC voltage and AC terminal voltage control, and conventional current control designed in the dq-domain, the ..alpha....beta.. -domain, and the positive-/negative-sequence domain. Moreover, this model is equipped with flexibility in selecting various types of current-limiting schemes, including saturation-based and latching-based current limiters, and anti-windup protection. Also, the EMT model is agnostic to the MVA rating and is suitable for interfacing transmission systems by complying with IEEE Std. 2800. The generality in the power circuits and the multifunctional options in the operation and control of the developed EMT model make it suitable for both academia and industry to study various power system aspects, including, but not limited to, the fault behavior of GFL IBRs, the impacts on the protection system, and the transient stability of a system interfaced with large numbers of GFL IBRs.

integrated circuit modeling↗

Thermo-Hydrological Modeling of Thermal Energy Storage in a Depleted Oil Reservoir

Thermal energy storage in oil and gas reservoirs leverages the existing surface and subsurface infrastructure, which can pave the way for economic production of geothermal energy. Existing studies on geothermal energy storage are focused mostly on the use of aquifers with more homogeneous rock and fluid properties. Coupling of heat and fluid flow in a multiphase-multicomponent system, such as an oil reservoir, is imperative especially if existing oil field assets need to be repurposed as required for a sustainable energy transition. The objective is to model the subsurface thermo-hydrological processes associated with reservoir performance and operational sustainability. The model evaluates formation pressure and temperature within the reservoir and at the injection/production wells during multiple charge and discharge cycles. Hot water (approximately 200 degrees C) heated by Concentrating Solar Power (CSP) at high pressure is injected into the existing oil reservoir for storage and produced as thermal energy for power generation, which will be accompanied by enhanced oil recovery. To demonstrate the coupled fluid and heat flow during the injection/production cycle in the subsurface reservoir, TOUGH3 (developed by Berkeley Lab) is used to simulate the thermo-hydrological (TH) processes in a multiphase, multicomponent system. Two well geometries are considered within the reservoir grid: 1) a single-well huff-n-puff system (same well is used for injection and production), and 2) an isolated injection-production well doublet. Seasonal charge and discharge cycling are implemented based on the scheduling specified in the model input file. The model reports pressure, temperature, enthalpy, liquid fluxes, heat fluxes, pore velocities, and changes in porosity & permeability due to temperature and pressure variations during the cyclic Reservoir Thermal Energy Storage (RTES) operations. The results from the simulations can be used to optimize the operational parameters (such as well spacing and injection/production rates) and round-trip efficiency for surface power-plants coupled with thermal energy storage over time. They can also serve as important inputs for levelized cost of storage estimations. The research will help to design and integrate surface renewable energy sources, such as concentrating solar power (CSP), with RTES to help balance out power supply and demand on the grid.

CSP↗

DSO+T: Valuation Methodology and Economic Metrics (DSO+T Study: Volume 4)

This report summarizes a rigorous valuation analysis methodology used by the Distribution System Operator with Transactive (DSO+T) study to estimate the financial benefits and costs of adopting Transactive Energy coordination of distributed energy resources for key stakeholders (for example distribution system operators and customers). This was achieved by modeling the value exchanges between stakeholders and determining the annualized costs and revenues experienced by stakeholders, enabling the evaluation of overall impact on stakeholder’s annualized cash flow. Extensive work was conducted developing methods to estimate the operating costs of distribution system operators at a level of granularity that would allow the financial impact of implementing a transactive energy approach to be estimated. This work included developing parametric models for labor and software costs, distribution system capital and maintenance costs, growth rates, and factors to determine annualized costs of capital investments. Simulation results were used to calculate wholesale energy costs and revenues from retail sales. Valuation analysis methods were also developed for other stakeholders including customers, the transmission system operator, independent system operator, and generators. The resulting capability allows a complete mapping of the flow of financial value between stakeholders that can be directly integrated with the results of demand flexibility simulations. Example results are provided for a business-as-usual case and compared to a transactive energy case as well as to actual cost data.

24 POWER TRANSMISSION AND DISTRIBUTION↗

PR100 Final Results

This presentation includes a summary of the final results from the Puerto Rico Grid Resilience and Transition to 100% Renewable Energy Study (PR100). Led by the U.S. Department of Energy's Grid Deployment Office and the National Renewable Energy Laboratory, and funded by the Federal Emergency Management Agency, the PR100 Study was a two-year effort resulting in stakeholder-driven pathways for Puerto Rico to meet its clean energy goals. For Spanish version see https://www.nrel.gov/docs/fy24osti/88975.pdf.

100% renewable energy target↗

Geothermal Deep Direct Use for Turbine Inlet Cooling in East Texas

The National Renewable Energy Laboratory (NREL), the Southern Methodist University Geothermal Laboratory (SMU), Eastman Chemical (Longview, TX), and TAS (Houston, TX) evaluated the feasibility of using geothermal heat to improve the performance of a natural-gas power plant in East Texas. The area of interest is the Eastman Chemical plant in Longview, Texas, which is on the northwestern margin of a geologic region known as the Sabine Uplift. The feasibility study focused on determining the potential for accessing a subsurface hot-water geothermal resource within a 10-km radius of the site to provide thermal energy for absorption chillers. Wells within a 20-km radius are included for broader geological comparison to determine the heat flow, temperature-at-depth, field porosity and permeability. The lithologies of most interest are the Lower Cretaceous Trinity Group and Upper Jurassic Cotton Valley Group. The deeper Cotton Valley formations are hotter (averaging 117 to 130°C), yet permeability and porosity are low. The shallower Trinity Group contains more variability in permeability and porosity and lower temperatures averaging about 98 to 117°C. The shallower formations are considered despite the lower temperature because of increased ability to produce larger volumes of water and extract enough heat before reinjection. The complete SMU analysis is available in the National Geothermal Data System (NGDS). Tapping such deep geothermal sources for direct heating (as opposed to power generation) is known as geothermal deep direct use (DDU). Geothermal DDU has potential across a wide swath of the United States but is underutilized due to challenging project economics associated with developing a deep geothermal resource for what are typically small-scale, variable-demand projects. This project examines the feasibility of geothermal energy integration in a natural-gas combined cycle power station in East Texas. The DDU resource is tapped to drive absorption chillers (24/7) for production of chilled water at 5-10°C (41-50°F). This chilled water is stored until needed, which allows for continuous operation with a relatively small-capacity geothermal/absorption chiller system. When conditions are favorable, the chilled water is dispatched to cool the air entering the compressor stage of a gas combustion turbine. This process, known as turbine inlet cooling (TIC), boosts power production during periods of high temperature and high-power demand. Such systems can enhance grid reliability and reduce the cost for peak-demand power. A simulation model of the power plant was developed in IPSEpro software and validated against operational data from the plant. This model allowed the team to estimate the additional power that could be produced by applying TIC under different operating and ambient conditions. Absorption chiller performance was estimated from vendor sources to determine the production rate of chilled water from the geothermal resource. Geothermal drilling and development costs were estimated using NREL's GEOPHIRES 2.0. The expected lower drilling costs in this region led to an estimated cost of geothermal heat of about $4/MMBtu (1.4 cents/kWh t ). The estimated cost for the absorption chillers and TIC hardware were obtained from literature sources and project partners. Hourly data were obtained for weather, natural gas and electricity prices, and plant operating state for 2017, which served as a representative year. NREL estimated the capital cost, operating cost, and additional electricity production and revenue for different combinations of geothermal capacity, chiller capacity, and water storage-tank size. The analysis drove toward smaller geothermal and chiller systems to reduce equipment cost. A relatively low-cost water storage tank accumulated the near-continuous chilled water output for later use when TIC was most valued.

15 GEOTHERMAL ENERGY↗

Derivation and assessment of regional electricity generation emission factors in the USA

Electricity production is one of the largest sources of environmental emissions - especially greenhouse gases (GHGs) - in the USA. Emission factors (EFs) vary from region to region, which requires the use of spatially relevant EF data for electricity production while performing life cycle assessments (LCAs). Uncertainty information, which is sought by LCA practitioners, is rarely supplied with available life cycle inventories (LCIs). To address these challenges, we present a method for collecting data from different sources for electricity generation and environmental emissions; discuss the challenges involved in agglomerating such data; provide relevant suggestions and solutions to merge the information; and calculate EFs for electricity generation processes from various fuel sources for different spatial regions and spatial resolutions. The EFs from the US 2016 Electricity Life Cycle Inventory (eLCI) are analyzed and explored in this study. We also explore the method of uncertainty information derivation for the EFs. We explore the EFs from different technologies across Emissions & Generation Resource Integrated Database (eGRID) regions in the USA. We find that for certain eGRID regions, the same electricity production technology may have worse emissions. This may be a result of the age of the plants in the region, the quality of fuel used, or other underlying factors. Region-wise life cycle impact assessment (LCIA) ISO 14040 impacts for total generation mix activities provide an overview of the total sustainability profile of electricity production in a particular region, rather than only global warming potential (GWP). We also find that, for different LCIA impacts, several eGRID regions are consistently worse than the US average LCIA impact for every unit of electricity generated. Here this work describes the development of an electricity production LCI at different spatial resolutions by combining and harmonizing information from several databases. The inventory consists of emissions, fuel inputs, and electricity and steam outputs from different electricity production technologies located across various regions of the USA. This LCI for electricity production in the USA will prove to be an enormous resource for all LCA researchers - considering the detailed sources of the information and the breadth of emissions covered by it.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Assessment of the polygeneration approach in wastewater treatment plants for enhanced energy efficiency and green hydrogen/ammonia production

Wastewater treatment plants (WWTPs) offer opportunities to optimize resource utilization and enhance energy efficiency. Here, this study provides a comprehensive analysis of using the polygeneration approach in WWTPs to reduce grid energy dependence, optimize energy distribution, and utilize surplus energy for hydrogen (H 2 ) and ammonia (NH 3 ) production. Several models were employed, including photovoltaic (PV) cells, parabolic trough collectors (PTCs), steam methane reforming, and polymer electrolyte membranes, to assess the feasibility of this approach. Three scenarios were evaluated and compared: Scenario 1 (Baseline) represents the current situation, Scenario 2 maximizes the Net Present Value (NPV), and Scenario 3 minimizes NH 3 production costs. Real data from As-Samra WWTP in Jordan was used to accurately assess the feasibility of each scenario. The results show that Scenario 2 offers the highest profitability and efficiency, with a NPV of 87.48 million USD and an annual NH 3 production of 15,417 tons, reducing both grid dependency and biogas fuel consumption. Both Scenarios 2 and 3 demonstrate the ability to meet thermal demands efficiently while generating significant revenue from NH 3 production. Scenario 3, in particular, achieves competitive H 2 and NH 3 production costs. Environmentally, Scenario 2 significantly reduces annual greenhouse gas emissions by 12.66 kilotons of CO 2eq , with near-zero carbon intensity for thermal energy due to solar reliance. In conclusion, the polygeneration approach offers a promising pathway for WWTPs to achieve greater sustainability, economic gains, and reduced environmental impact, providing valuable insights for decision-makers.

42 ENGINEERING↗

Power Sector Transformation Pathways: Exploring Objectives, Factors, and Technology Innovations to Inform Power Sector Pathway Decisions

The power and heating sectors are responsible for around 30% of global CO2 emissions and this share is likely to grow as countries move towards electrification of the transportation and building sectors. Therefore, enabling forward-thinking, long term strategies in the power sector is a crucial area for international collaboration and support. The rapid transition of power systems toward modern, low-carbon pathways and technologies will be necessary to meet key climate goals while also enabling other critical objectives such as economic development, energy access, and energy system resiliency, among others. Many developed and developing countries are well-poised to champion power sector transformation (PST), however, further support is needed to identify pathways and implement critical near and long-term actions. To address this need, the Low Emission Development Strategies Global Partnership (LEDS GP) together with an expert team including Agora Energiewende, Energy Innovation, European Climate Foundation, Fraunhofer Institute for Systems and Innovation Research , Prayas Energy Group and LEDS Latin America and Caribbean Platform, developed a framework identifying four key pathways that can be integrated and combined to support low-carbon PST. These four pathways are: (1) Distributed Energy Resource Revolution, (2) Bulk Power Transformation, (3) Transmission and Distribution Interactivity, and (4) Distributed Transactional Future. To support exploration of pathways, this study examines PST objectives and factors that may lead countries or jurisdictions to place a greater relative emphasis on certain pathways as well as a framework and complementary tool for considering the emphasis in a hands on manner. The report provides case studies on application of the approach to bring life to the topic. The case studies include Haiti, Kenya, Mexico, Southeast Asia, and the European Union, among others. The report also presents actions to-be-taken in the near-, medium- and long-term to support the realization of pathways and long-term transformation of the power sector. The report, together with a complementary spreadsheet tool developed under the effort, can be used to enable stakeholder engagement and visioning for the power sector over the long-term, taking into account key factors and potential innovations. It can also be used to understand and inform relevant analysis tools and models based on which pathways are emphasized, and to identify key actions in the near- and medium-term to avoid lock-in of carbon-intensive technologies.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Anomaly Detection and Mitigation for Wide-Area Damping Control using Machine Learning

In an interconnected multi-area power system, wide-area measurement based damping controllers are used to damp out inter-area oscillations, which jeopardize grid stability and constrain the power flows below to their transmission capacity. The effect of wide-area damping control (WADC) significantly depends on both power and cyber systems. At the cyber system layer, an adversary can inflict the WADC process by compromising either measurement signals, control signals or both. Stealthy and coordinated cyber-attacks may bypass the conventional cybersecurity measures to disrupt the seamless operation of WADC. This paper proposes an anomaly detection (AD) algorithm using supervised Machine Learning and a model-based logic for mitigation. The proposed AD algorithm considers measurement signals (input of WADC) and control signals (output of WADC) as input to evaluate the type of activity such as normal, perturbation (small or large signal faults), attack and perturbation-and-attack. Upon anomaly detection, the mitigation module tunes the WADC signal and sets the control status mode as either wide-area mode or local mode. The proposed anomaly detection and mitigation (ADM) module works inline with the WADC at the control center for attack detection on both measurement and control signals and eliminates the need for ADMs at the geographically distributed actuators. Here, we consider coordinated and primitive data-integrity attack vectors such as pulse, ramp, relay-trip and replay attacks. The performance of the proposed ADM algorithms was evaluated under these attack vector scenarios on a testbed environment for 2-area 4-machine power system. The ADM module shows effective performance with 96:5% accuracy to detect anomalies.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Puerto Rico Grid Resilience and Transitions to 100% Renewable Energy Study (PR100) (Summary Report)

The Puerto Rico Grid Resilience and Transitions to 100% Renewable Energy Study (PR100) is a comprehensive analysis based on extensive stakeholder input of possible pathways for Puerto Rico to achieve its goal of 100% renewable energy by 2050. In this summary report of the PR100 Final Report, we describe the background and motivation behind the study, provide an overview, summarize results, highlight key findings, and outline implementation actions for stakeholders to take in the immediate-, near-, mid-, and long-term to achieve Puerto Rico’s energy system goals.

100% renewable energy target↗

Microstructure-Sensitive Uncertainty Quantification for Crystal Plasticity Finite Element Constitutive Models Using Stochastic Collocation Methods

Uncertainty quantification (UQ) plays a major role in verification and validation for computational engineering models and simulations, and establishes trust in the predictive capability of computational models. In the materials science and engineering context, where the process-structure-property-performance linkage is well known to be the only road mapping from manufacturing to engineering performance, numerous integrated computational materials engineering (ICME) models have been developed across a wide spectrum of length-scales and time-scales to relieve the burden of resource-intensive experiments. Within the structure-property linkage, crystal plasticity finite element method (CPFEM) models have been widely used since they are one of a few ICME toolboxes that allows numerical predictions, providing the bridge from microstructure to materials properties and performances. Several constitutive models have been proposed in the last few decades to capture the mechanics and plasticity behavior of materials. While some UQ studies have been performed, the robustness and uncertainty of these constitutive models have not been rigorously established. In this work, we apply a stochastic collocation (SC) method, which is mathematically rigorous and has been widely used in the field of UQ, to quantify the uncertainty of three most commonly used constitutive models in CPFEM, namely phenomenological models (with and without twinning), and dislocation-density-based constitutive models, for three different types of crystal structures, namely face-centered cubic (fcc) copper (Cu), body-centered cubic (bcc) tungsten (W), and hexagonal close packing (hcp) magnesium (Mg). Our numerical results not only quantify the uncertainty of these constitutive models in stress-strain curve, but also analyze the global sensitivity of the underlying constitutive parameters with respect to the initial yield behavior, which may be helpful for robust constitutive model calibration works in the future.

36 MATERIALS SCIENCE↗

Upscaling Methane Flux From Plot Level to Eddy Covariance Tower Domains in Five Alaskan Tundra Ecosystems

Spatial heterogeneity in methane (CH 4 ) flux requires a reliable upscaling approach to reach accurate regional CH 4 budgets in the Arctic tundra. In this study, we combined the CLM-Microbe model with three footprint algorithms to scale up CH 4 flux from a plot level to eddy covariance (EC) tower domains (200 m × 200 m) in the Alaska North Slope, for three sites in Utqiaġvik (US-Beo, US-Bes, and US-Brw), one in Atqasuk (US-Atq) and one in Ivotuk (US-Ivo), for a period of 2013–2015. Three footprint algorithms were the homogenous footprint (HF) that assumes even contribution of all grid cells, the gradient footprint (GF) that assumes gradually declining contribution from center grid cells to edges, and the dynamic footprint (DF) that considers the impacts of wind and heterogeneity of land surface. Simulated annual CH 4 flux was highly consistent with the EC measurements at US-Beo and US-Bes. In contrast, flux was overestimated at US-Brw, US-Atq, and US-Ivo due to the higher simulated CH 4 flux in early growing seasons. The simulated monthly CH 4 flux was consistent with EC measurements but with different accuracies among footprint algorithms. At US-Bes in September 2013, RMSE and NNSE were 0.002 μmol m −2 s −1 and 0.782 using the DF algorithm, but 0.007 μmol m −2 s −1 and 0.758 using HF and 0.007 μmol m −2 s −1 and 0.765 using GF, respectively. DF algorithm performed better than the HF and GF algorithms in capturing the temporal variation in daily CH 4 flux each month, while the model accuracy was similar among the three algorithms due to flat landscapes. Temporal variations in CH 4 flux during 2013–2015 were predominately explained by air temperature (67–74%), followed by precipitation (22–36%). Spatial heterogeneities in vegetation fraction and elevation dominated the spatial variations in CH 4 flux for all five tower domains despite relatively weak differences in simulated CH 4 flux among three footprint algorithms. The CLM-Microbe model can simulate CH 4 flux at both plot and landscape scales at a high temporal resolution, which should be applied to other landscapes. Integrating land surface models with an appropriate algorithm provides a powerful tool for upscaling CH 4 flux in terrestrial ecosystems.

54 ENVIRONMENTAL SCIENCES↗

Estudio de Resiliencia de la Red Electrica de Puerto Rico y Transiciones a Energia 100% Renovable (PR100): Informe resumido [Spanish Translation of Puerto Rico Grid Resilience and Transitions to 100% Renewable Energy Study (PR100) (Summary Report)]

The Puerto Rico Grid Resilience and Transitions to 100% Renewable Energy Study (PR100) is a comprehensive analysis based on extensive stakeholder input of possible pathways for Puerto Rico to achieve its goal of 100% renewable energy by 2050. In this summary report of the PR100 Final Report, we describe the background and motivation behind the study, provide an overview, summarize results, highlight key findings, and outline implementation actions for stakeholders to take in the immediate-, near-, mid-, and long-term to achieve Puerto Rico’s energy system goals. For the English version of this report, see NREL/TP-6A20-88615 (https://www.nrel.gov/docs/fy24osti/88615.pdf).

100% renewable energy target↗

Simulation of 15% and 50% Thermal Power Dispatch to an Industrial Facility Using a Flexible Generic Full-Scope Pressurized Water Reactor Plant Simulator

Nuclear power plants in the United States are increasingly challenged to compete in wholesale electricity markets due to the low electricity costs and increasingly dynamic grid conditions from competing generation sources. An alternative market for nuclear power is industrial facilities that can use the thermal and/or electrical power generated by a nuclear power plant to offset the economic losses incurred by electricity market challenges. A generic pressurized water reactor (PWR) simulator was used to show the results of a basic design for a generic thermal power extraction system and tests were run using a set of procedures to show what happens when a nuclear power plant transitions from full electrical power dispatch to 15% and 50% thermal power dispatch. This type of operation leads to losses in turbine performance efficiency due to the deviation from the design operating point, but because the thermal power is also used by the industry load without conversion losses, the combined thermal efficiency of the PWR increases. For the 15% case, the thermal efficiency increased from 32% to 41.9%, while for the 50% case, the efficiency increased up to 60.1%. In addition, for 50% thermal power dispatch, the power dissipated by the condenser decreased from approximately 2000 to approximately 1300 MW (thermal), indicating a substantially diminished impact on the environment in terms of releasing heat into the cooling water reservoir.