At least 847 records · Page 47

Pre-conceptual Evaluation of DOD Pele Microreactor Sites at Idaho National Laboratory

Members of the INL Land Use Committee met to discuss potential options and make recommendations for siting the Pele microreactor demonstration and testing projects at INL. The Pele microreactor prototype will be a DOE authorized reactor. The evaluation team of subject matter experts (SME) was asked to consider both indoor sites and outdoor sites. A preliminary evaluation was performed by the SME team and based on those discussions the following recommendations were made: (1) Present EBR-II as the most suitable indoor site, and (2) Utilize CITRC Pads A-D as a system of outdoor demonstration and testing sites. Each pad has its own set of attributes that have been established to enable equipment testing and can provide options for various configurations when the group of pads are used as a system of testing sites. Utilizing CITRC Pads A-D as a system of sites offers flexibility in scheduling activities at CITRC to meet existing program schedules and future Pele program demonstration and testing needs with the least programmatic impact.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Evaluation report on the Thermo Scientific TruDose (neutron,gamma) EPD3

This report summarizes an evaluation study on the Thermo Scientific TruDose n/γ EPD3 by LANL’s RP-SVS group. Two EPD3s were received for assessment (SNs 7500100 and 7500108) along with an EPD3 desktop reader. The evaluation included intercomparisons with Thermo’s N2 EPD which is in wide circulation at LANL but is no longer commercially available. A favourable assessment of the TruDose EPD3 would help support it as a viable option to replace the N2 EPD. The data and observations included in this report could also serve as the basis of a Technical Basis Document for the use of the EPD3 at LANL.

61 RADIATION PROTECTION AND DOSIMETRY↗

Sludge Batch 10 (SB10) Acceptance Evaluation: Radionuclide Concentrations in Tank 51 Washed Qualification Sample

Savannah River National Laboratory (SRNL) has been tasked with the radionuclide characterization of the washed Sludge Batch 10 (SB10) qualification sample. The washed SB10 qualification sample is based on SRR Engineering guidance and the sample slurry is expected to be similar in composition to Tank 51 slurry after final preparations for transfer to Tank 40. Forty-four radionuclides along with total alpha and beta activity have been reported herein. These radionuclide measurements are required for the Defense Waste Processing Facility (DWPF) Radiological Evaluation Program, DWPF Technical Safety Requirements (TSR)/Waste Acceptance Criteria (WAC) Evaluation, and the DWPF Solid Waste Characterization Program.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Test Results for Checking Reliability of Selected ENDF/B-VIII.0 Evaluated Uncertainties

This report summarizes error messages obtained from counter-checking whether 1 H, 9 Be, 12 C, 27 Al, 235,238 U and 238–242 Pu relative uncertainties of ENDF/B-VIII.0 are realistic. Large parts of this report were generated automatically by the code CovVal. This code allows to test the reliability of relative uncertainties of any isotope. It gives generic error and warning messages if evaluated relative uncertainties of a particular reaction are likely under- or over-estimated. In addition to these error and warning messages, I added comments whether the flagged uncertainties are truly under- or overestimated. I call out these uncertainties that should be further investigated and corrected by an evaluator for an upcoming release of ENDF/B-VIII.1.

07 ISOTOPE AND RADIATION SOURCES↗

AI-Enabled Robots for Automated Nondestructive Evaluation and Repair of Power Plant Boilers. Final Report

Boiler failure could cause loss of life and safety issues, cost hundreds of thousands of dollars in equipment repairs, property damage and production losses, and drive up the cost of electric power. Boiler maintenance is challenging and risky for inspectors working on scaffolding in confined hazardous spaces inside of a boiler and sometimes the space is hard to access. The operation is also time-consuming due to the large area of vertical structures for inspection and the tremendous effort needed for scaffolding. Recently, the use of robotics (e.g., drones and crawlers) in power plants for maintenance is growing rapidly. However, the existing robotics solutions show two notable technological gaps: no live repair capability, and no Artificial Intelligence (AI) for smart autonomy. The objective of this project is to develop an integrated autonomous robotic platform that is equipped with compact non-destructive evaluation (NDE) sensors to perform live inspection, operates onboard repair devices to perform live repair, and uses AI for intelligent data fusion and predictive analysis for automated and smart spatiotemporal inspection, analysis and repair of the furnace walls in coal-fired boilers. The approach to achieve the objective includes developing NDE sensors with signal processing techniques, designing and evaluating repair devices for robots based on fusion and solid-state technologies, and an autonomous robotic platform that can attach to and navigate on boiler furnace walls using magnetic drive tracks. The robot is also powered by AI to automate data gathering (e.g., 3D mapping and damage localization) and predictive analysis. This project has advanced the state-of-the-art by providing technological breakthroughs including compact NDE and repair tools for robots, AI capabilities for smart autonomy, and a robotic platform for automated boiler maintenance. This project has great potential to result in significant benefits including limiting or eliminating the need to send operators to assess difficult-to-access or hazardous areas, enabling automated live inspection and repair, avoiding time consuming scaffolding (especially for partial maintenance during unplanned outage), collecting comprehensive and well-organized data smartly, and avoiding or limiting the need for onsite or remote piloting technicians. The impacts can be tremendous in terms of the time and cost savings, reducing the risk for human operators, and increasing boiler reliability, usability, and efficiency. In addition, by developing the new technologies on the autonomous inspection and repair robot, by involving multiple undergraduate and graduate students working together with the faculty members on this project, and by generating knowledge and building up collaborations with industrial partners, this effort will significantly update the education capabilities, support long-term fundamental research, and maintain the leadership of Colorado School of Mines and Michigan State University in energy fields.

20 FOSSIL-FUELED POWER PLANTS↗

Evaluation and Suitability of Using SERI QC Software for Estimating Measurement Uncertainty

SERI QC is a robust solar data quality assessment software tool that has been in continuous use for more than three decades. This report (the first of six in the Data Quality and Uncertainty Integration project) reviews and evaluates the software to determine its suitability for determining the estimated expanded measurement uncertainty of solar measurement data by including operational factors. Using redundancy incorporated in three-component (global, direct, diffuse) solar measurements, SERI QC can quantify the standard uncertainty estimates for estimating uncertainty. With minor modifications, SERI QC will provide an operational uncertainty to be used in conjunction with the National Renewable Energy Laboratory method for instrument uncertainty to provide an integrated estimate of solar measurement data sets. These modifications will capitalize on SERI QC's evaluation of data quality, including data input validation and a variety of built-in solar routines, and will further develop the utility of the software.

14 SOLAR ENERGY↗

Advances in Nuclear Data Evaluation Theory for NCSP [Slides]

The generalized form of the Bayes’ Theorem improves UQ for NCSP of differential and/or integral data evaluations and of applications. It is being implemented in an API for use by SCALE, SAMMY, etc. Extended R-matrix formalism improves evaluations of RRR including direct reactions, direct capture, and the Reich-Moore approx., doorway state reactions with applications to RPI data on lead isotopes. Extended R-Matrix formalism will be implemented into SAMMY post modernization.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Updates to the n+ 63,65 Cu Evaluations: RRR and Angular Distributions [Slides]

This work updates the evaluation of n+ 63,65 Cu for neutron energies in the resolved resonance region (RRR) and slightly higher energies. The updates strive to improve the statistical properties of the resonance parameters and the continuity of the evaluation between the RRR and the high-energy region while preserving or improving critical assembly benchmark performance. We will review our work on the resonance parameters and present the current status of our angular distribution analysis.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Status of the Optical Dilatometer Method of Evaluating the Peak Irradiation Temperatures of SiC Passive Monitors

The main objective of this project was to conduct a comparative assessment between the optical dilatometer method and resistivity method, using all 10 SiC temperature monitors provided by two Nuclear Science User Facility experiments: BSU-8242 and General Electric Hitachi. Unfortunately, due to multiple delays in acquiring, shipping, and cleaning the SiC temperature monitors, the project was only able to process one (1) SiC temperature monitor during this period. SiC temperature monitor KGT-3357 was evaluated via the optical dilatometer method to determine its peak irradiation temperature. The KGT-3357 sample was from the BSU-8242 experiment and designed for a temperature of 300°C and an exposure of 1 dpa. The optical dilatometer measurements indicated that the KGT-3357 SiC temperature monitor’s peak irradiation temperature range was 240–267°C, with sensitivity of approximately ±20°C. Additionally, this temperature range falls within the evaluated melt wire temperature range of 238.6–271.5 °C. The remaining six (6) SiC temperature monitors from the BSU-8242 experiment and three (3) from the General Electric Hitachi experiment will be used in the future work to further validate the optical dilatometer method for measuring SiC peak irradiation temperatures.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Synthetic Sling Failure: Evaluations and Recommendations

The information and evaluations provided in this report were compiled to address the recurring problem of synthetic sling failure. As safety is the number one priority in all work aspects, a solution must be devised to prevent accidents from occurring. In revision 0, a total of thirteen cases regarding synthetic sling failure were evaluated in order to determine their causes, effects, and preventative measures. From the collected data, it was found that all cases in which the synthetic sling contacted the edge of its load resulted in sling failure. Revision 1 provides updated synthetic fling failures between the years of 2009 revision 0 and 2021 revision 1.

42 ENGINEERING↗

Evaluating the Impacts of the Bipartisan Budget Act of 2018 45Q Tax Credit on CCS Network Costs

This study evaluates the impact of the Bipartisan Budget Act of 2018 (BBA)-amended 45Q tax credit on integrated carbon capture and storage (CCS) networks for source types and geologic storage reservoirs common to the north-central U.S. The integrated CCS networks evaluated were chosen to closely replicate those in the forthcoming National Energy Technology Laboratory (NETL) central U.S. CCS cost options study’s Northwest CCS Network Regional Impact Area (Northwest Impact Area).

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Evaluation Of Glass Density to Support the Estimation of Fissile Mass Loadings in Sludge Batch 10 Glasses

Per a directive from the Department of Energy Savannah River Operations Office (DOE-SR) in 2008, the fissile mass loading concentration must remain below 897 g/m 3 in each high-level waste (HLW) glass canister produced by the Defense Waste Processing Facility (DWPF). To support Sludge Batch 5 (SB5) processing, the Savannah River National Laboratory (SRNL) developed a technical basis that facilitates the evaluation of fissile mass loading of the glass product. The calculation is based on the iron (Fe) concentration in the glass as determined by measurements from the Slurry Mix Evaporator acceptability analysis as well as the glass density. In April 2022, a subsequent DOE-SR directive increased the fissile mass loading limit to 2500 g/m 3 beginning with Sludge Batch 11. Thus, the 897 g/m 3 limit still applies to Sludge Batch 10 (SB10) processing. For SB5 through initial Sludge Batch 9 (SB9) processing prior to coupled operation with the Salt Waste Processing Facility (SWPF), SRNL provided DWPF a bounding glass density value that was based on a statistical evaluation of density measurements. To eliminate the need for experimental work, a composition-based density model for HLW glasses was developed at SRNL in 2019. The objective of this report is to present the bounding glass density determined with the composition-based density model for SB10 sludge-only (SO) and coupled processing.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

239 Pu(n,f) Neutron Multiplicity Evaluation with CGMF-Very First Release Candidate. [Slides]

239 Pu(n,f) nu-bar evaluated with CGMF from E inc = 0.1-20 MeV. Changes compared to VIII.0: Prior: CGMF model included via Kalman and sensitivities of CGMF model parameters to nu-bar. Evaluation technique: Kalman including correction for PPP. Experimental data: Nearly all data that Phil took into account (I rejected: Huanqiao, Johnstone, Leroy, Nesterov, Smirenkin); New UQ for all experimental data; Marini; No correlations between unc. of different exp., except for Cf-252(sf) nu-bar uncertainty cross-correlating all uncertainties.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Evaluation of Oak Ridge National Laboratory Health Physics Research Reactor Operation Data for Critical Benchmark Creation [Slides]

During the evaluation of Oak Ridge National Laboratory Health Physics Research Reactor operation data for critical benchmark creation, a detailed, functional SCALE model was built, and experimental data was evaluated for the creation of a critical benchmark. The estimated experimental uncertainty is about 3800 pcm, which is considered very high. The relative difference between expected and calculated keff values is about 1.5 %, also considered very high. It was concluded that a good quality critical benchmark worthy of the ICSBEP standards cannot be created from HPRR data in the present conditions. Locating the HPRR fuel to obtain an uncertainty on the density would aid in solving this issue.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

E-Area Corrosion Coupon Recovery and Evaluation

The recovery and evaluation of selected E-Area corrosion coupons were completed in FY2022. This is the second time coupons have been recovered from the E-Area Corrosion Monitoring Test Site, with the first recovery effort occurring in FY2017. Coupons recovered during the FY2022 extraction have now been exposed to the subsurface for approximately 17 years. This effort is part of an ongoing study where a subset of coupons is recovered at each determined time interval over a 100-year period. Results from this effort, as well as updates to the schedule for future recovery and evaluation efforts, are included in this report revision. This report is issued as a revision to the 2018 report and maintains similar formatting.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Update on NNL TSL Evaluations and Validation [Slides]

12 new/revised TSL evaluations were contributed to ENDF/B-VIII.1. The thermal diffusion length $L$ is an integral property of a single material’s absorption and scattering cross sections (both differential and integral). No other neutron reactions or materials are involved. The MC21-calculated $L$ for water is consistent with the spread of experimental data and is sufficiently sensitive to different H-H 2 O TSL physics models to use the method as a TSL integral performance benchmark. Modern high-quality diffusion experiments at elevated $T$ would allow direct low-cost physics benchmarking of water TSLs when public elevated-$T$ critical benchmarks are limited. NNL is working with LLNL and RPI to develop experimental PNDA capability. An ICSBEP Fundamental Physics benchmark of the Nassar and Murphy PNDA experiment is being developed to provide an example of how to evaluate these type of benchmarks.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Experiments for validation of TSL evaluations [Slides]

There is a recent revival of thermal scattering evaluation capabilities and there are many new evaluations available in ENDF-8.0 and elsewhere. This creates a need for experimental validation other than criticality benchmarks. Thermal scattering libraries (TSL) provide information to describe the double differential thermal scattering at different moderator temperatures. For moderators, the biggest effect of TSL is the thermal scattering cross section.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

EDA R-Matrix Evaluations Report on n+ 9 Be, n+ 16 O [Slides]

This presentation discusses new developments in light-element R-matrix evaluation and recent light-element work. The presentation also reviewed R-matrix theory, EDAf90 code implementation, including interface EDAf90 with NJOY, ENDFtk, EXFOR/CSISRS, and a new evaluation for n+ 9 Be. The presentation concludes by stating that further development is needed.