Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “direct injection”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 847 records · Page 47

Spacecraft Fire Suppression: Testing and Evaluation

The objective of this project is the testing and evaluation of the effectiveness of a variety of fire suppressants and fire-response techniques that will be used in the next generation of spacecraft (Crew Exploration Vehicle, CEV) and planetary habitats. From the many lessons learned in the last 40 years of space travel, there is common agreement in the spacecraft fire safety community that a new fire suppression system will be needed for the various types of fire threats anticipated in new space vehicles and habitats. To date, there is no single fire extinguishing system that can address all possible fire situations in a spacecraft in an effective, reliable, clean, and safe way. The testing conducted under this investigation will not only validate the various numerical models that are currently being developed, but it will provide new design standards on fire suppression that can then be applied to the next generation of spacecraft extinguishment systems. The test program will provide validation of scaling methods by conducting small, medium, and large scale fires. A variety of suppression methods will be tested, such as water mist, carbon dioxide, and nitrogen with single and multiple injection points and direct or distributed agent deployment. These injection methods cover the current ISS fire suppression method of a portable hand-held fire extinguisher spraying through a port in a rack and also next generation spacecraft units that may have a multi-point suppression delivery system built into the design. Consideration will be given to the need of a crew to clean-up the agent and recharge the extinguishers in flight in a long-duration mission. The fire suppression methods mentioned above will be used to extinguish several fire scenarios that have been identified as the most relevant to spaceflight, such as overheated wires, cable bundles, and circuit boards, as well as burning cloth and paper. Further testing will be conducted in which obstructions and ventilation will be added to represent actual spacecraft conditions (e.g., a series of cards in a card rack).

Abbud-Madrid, Angel↗

Major Influence of Tropical Volcanic Eruptions on the Stratospheric Aerosol Layer During the Last Decade

The variability of stratospheric aerosol loading between 1985 and 2010 is explored with measurements from SAGE II, CALIPSO, GOMOS/ENVISAT, and OSIRIS/Odin space-based instruments. We find that, following the 1991 eruption of Mount Pinatubo, stratospheric aerosol levels increased by as much as two orders of magnitude and only reached background levels between 1998 and 2002. From 2002 onwards, a systematic increase has been reported by a number of investigators. Recently, the trend, based on ground-based lidar measurements, has been tentatively attributed to an increase of SO2 entering the stratosphere associated with coal burning in Southeast Asia. However, we demonstrate with these satellite measurements that the observed trend is mainly driven by a series of moderate but increasingly intense volcanic eruptions primarily at tropical latitudes. These events injected sulfur directly to altitudes between 18 and 20 km. The resulting aerosol particles are slowly lofted into the middle stratosphere by the Brewer-Dobson circulation and are eventually transported to higher latitudes.

Vernier, Jean-Paul↗

A Fast, Accurate and Sensitive GC-FID Method for the Analyses of Glycols in Water and Urine

Glycols, specifically ethylene glycol and 1,2-propanediol, are some of the major organic compounds found in the humidity condensate samples collected on the International Space Station. The current analytical method for glycols is a GC/MS method with direct sample injection. This method is simple and fast, but it is not very sensitive. Reporting limits for ethylene glycol and 1,2-propanediol are only 1 ppm. A much more sensitive GC/FID method was developed, in which glycols were derivatized with benzoyl chloride for 10 minutes before being extracted with hexane. Using 1,3-propanediol as an internal standard, the detection limits for the GC/FID method was determined to be 50 ppb and the analysis only takes 7 minutes. Data from the GC/MS and the new GC/FID methods shows excellent agreement with each other. Factors affecting the sensitivity, including sample volume, NaOH concentration and volume, volume of benzoyl chloride, reaction time and temperature, were investigated. Interferences during derivatization and possible method to reduce interferences were also investigated.

Kuo, C. Mike↗

Effect of Air Swirler Configuration on Lean Direct Injector Flow Structure and Combustion Performance with a 7-Point Lean Direct Injector Array

Studies of various injector configurations in a 7-point Lean Direct Injector (LDI) array are reported for both non-reacting (cold) flow and for Jet-A/air reacting flows. For cold flow, central recirculation zone (CRZ) formation is investigated and for reacting flows, combustor operability and dynamics are of interest. 2D Particle Image Velocimetry (PIV) measurements are described for the cold flow experiments and flame chemiluminescence imaging and dynamic pressure results are discussed for the reacting flow cases. PIV results indicate that for this configuration the close spacing between swirler elements leads to strong interaction that affects whether a CRZ forms, and pilot recess and counter-swirl helps to isolate swirlers from one another. Dynamics results focus on features identified near 500-Hz.

aircraft combustors↗

Chemiluminescence Measurements in a Combustor Using a 7-Point Lean Direct Injector Array Configuration for Gas Turbine Engine Applications

Two different configurations of a 7-point lean direct injector array were investigated. Chemiluminescence images of C2* or CH* were collected during combustion tests for insight on flame structure for the two configurations. Several inlet conditions were tested by varying the equivalence ratio or reference velocity. For the center right-hand 60 degree and outer right-hand 52 degree outers, the chemiluminescence emanating from the central pilot appeared well isolated from the outers. At the same time, a hollow region below the pilot showed little fluctuation of chemiluminescence where a central recirculation zone was present during the non-reacting tests. The central left-hand 60 degree and outer right-hand 52 degree configuration displayed a narrower structure from the pilot compared to the flatter pilot observed in the other configuration. Additionally, the right-handed outer swirlers may be responsible for the asymmetry observed with the chemiluminescence images. Both configurations showed less variation in chemiluminescence intensity as the reference velocity was increased. This was likely due to better atomization and vaporization associated with higher fuel and air flow rates.

lean direct injection↗

Fundamental Study of a 7-Element Fuel Injector Configuration for Gas Turbine Combustors, a Look at Cold Flow and Burning Measurements

As part of a parametric study in which we vary swirler angle and orientation and look at their effect on fluid mixing and combustion, we examine one configuration of a 7-point lean direct injector by looking at the non-combusting 2-D velocity field using PIV (Particle Image Velocimetry), and combusting system for chemical species using chemiluminescent imaging and flame spectroscopy. The circular 7-point array consists of axial swirlers, with the center 60 degree counterclockwise swirler surrounded by six 52 degree clockwise swirlers. The velocity results for this configuration show that the outer swirlers serve to isolate the center flow field near the injector exit. A recirculation zone forms downstream of the center swirler, but not behind the outer swirlers. The combusting results also show an isolated zone directly downstream of the center injector. The flame spectra show variation in speciation of combustion species such as OH* and CH*, and as a function of position within the combustor.

lean direct injection↗

Chemiluminescence Measurements in a Combustor Using a 7-Point Lean Direct Injector Array Configuration for Gas Turbine Engine Applications

This paper reports results for a 7-point lean direct injector (LDI) array for a particular configuration. The LDI configuration in this study used a 60 degrees center pilot swirler and 52.5 degrees on the six outer swirlers. Chemiluminescence images of C2 and CH were collected at a frame rate of 25 Hz using an intensified CCD camera. Narrow bandwidth filters were coupled with the CCD camera in order to spectrally isolate C2 and CH signals. C2 was captured at 515 nm, and the CH signal was acquired at 430 nm. Six inlet conditions were considered in this study, all with the same inlet pressure, 75 psia, and same inlet temperature, 800 degcrees Fahrenheit. These conditions aimed to observe the effect of equivalence ratio, fuel staging, and reference velocity on C2 and CH emissions. Based on the chemiluminescence images, the changes in the inlet conditions was evident in both the pilot and outers. Additionally, the pilot (center injector element) appeared well isolated from the six outer elements under all test conditions.

lean direct injection↗

Dual-mode Propulsion System Enabling Cubesat Exploration of the Solar System

It is apparent the cost of planetary exploration is rising as mission budgets are declining. Currently small scientific beds geared to performing limited tasks are being developed and launched into low earth orbit (LEO) in the form of small-scale satellite units, i.e., CubeSats. These micro- and nano-satellites are gaining popularity among the university and science communities due to their relatively low cost and design flexibility. To date these small units have been limited to performing tasks in LEO utilizing solar-based power. If a reasonable propulsion system could be developed, these CubeSat platforms could perform exploration of various extra-terrestrial bodies within the solar system engaging a broader range of researchers. Additionally, being mindful of mass, smaller cheaper launch vehicles (~1,000 kg to LEO) can be targeted. This, in effect, allows for beneficial exploration to be conducted within limited budgets.Researchers at the Center for Space Nuclear Research (CSNR) are proposing a low mass, radioisotope-based, dual-mode propulsion system capable of extending the exploration realm of these CubeSats out of LEO.The proposed radioisotope-based system would leverage the high specific energies [J/kg] associated with radioisotope materials and enhance their inherent low specific powers [W/g]. This is accomplished by accumulating thermal energy from nuclear decay within a central core over time. This allows for significant amounts of power to be transferred to a flowing gas over short periods of time. In the proposed configuration the stored energy can be utilized in two ways: (1) with direct propellant injection to the core, the energy can be converted into thrust through the use of a converging-diverging nozzle and (2) by flowing a working fluid through the core and subsequent Brayton engine, energy within the core can be converted to electrical energy. The first scenario achieves moderate ranges of thrust, but at a higher Isp than traditional chemical-based systems. The second scenario allows for the production of electrical power, which is then available for electric-based propulsion. Additionally, once at location the production of electrical power can be dedicated to the payload's communication system for data transfer. Ultimately, the proposed dual-mode propulsion platform capitalizes on the benefits of two types of propulsion methods the thrust of thermal propulsion ideal for quick orbital maneuvers and the specific impulse of electric propulsion ideal for efficient interplanetary travel. Overall, the system is functioning as a radioisotope thermal rocket (RTR).In this study the RTR concept is being developed as an in-space propulsion system to deliver a 6U CubeSat payload to the orbit of the Saturnian moon - Enceladus. Additionally, this study will develop an entire mission architecture for Enceladus targeting a total allowable launch mass of 1,000 kg.

Cubesats↗

Comparison of Non-Combusting Spray Fields in a Model Combustor using Shadowgraphy

Droplet sizes were measured using shadowgraphy in the spray issuing from the center element of the baseline configuration of the NASA 7-element lean direct injector (LDI) array. Each LDI element consisted of a 60 degree clockwise axial air swirler, converging-diverging venturi, and a pressure-swirl atomizer positioned with its tip at the venturi throat. The non-combusting measurements were conducted using water spray in a 3-inch diameter research combustor operating at pressure of 5 bar and air inlet temperature of 700 K. At these inlet conditions, three air flow rates were used, producing reference velocities of 7.6, 15.2, and 22.9 m/s. Only the center nozzle was used. At each reference velocity, water flow rates were adjusted to simulate a common equivalence. Data were collected at a frame rate of 15 Hz over a range of positions near the LDI dump plane, and downstream, along the combustor centerline. Velocity measurements were achieved by use of a dual head Nd:YAG laser and frame transfer PIV camera. Droplet size and velocity, mass and number density, and volume fraction are compared at these inlet conditions to determine the effect of nozzle pressure drop on the measured properties.

lean direct injection↗

Comparison of Non-Combusting Spray Fields in a Model Combustor using Shadowgraphy

Droplet sizes were measured using shadowgraphy in the spray issuing from the center element of the baseline configuration of the NASA 7-element lean direct injector (LDI) array. Each LDI element consisted of a 60 degree clockwise axial air swirler, converging-diverging venturi, and a pressure-swirl atomizer positioned with its tip at the venturi throat. The non-combusting measurements were conducted using water spray in a 3-inch diameter research combustor operating at pressure of 5 bar and air inlet temperature of 700 K. At these inlet conditions, three air flow rates were used, producing reference velocities of 7.6, 15.2, and 22.9 m/s. Only the center nozzle was used. At each reference velocity, water flow rates were adjusted to simulate a common equivalence. Data were collected at a frame rate of 15 Hz over a range of positions near the LDI dump plane, and downstream, along the combustor centerline. Velocity measurements were achieved by use of a dual head Nd:YAG laser and frame transfer PIV camera. Droplet size and velocity, mass and number density, and volume fraction are compared at these inlet conditions to determine the effect of nozzle pressure drop on the measured properties.

lean direct injection↗

School Districts Move to the Head of the Class with Propane

Propane has been a proven fuel for buses for decades. For the first time in 2007, Blue Bird rolled out a propane school bus using direct liquid injection, which was later followed by Thomas Built Buses and Navistar. Because this new technology is much more reliable than previous designs, it is essentially reintroducing propane buses to many school districts. During this same time period, vehicle emissions standards have tightened. To meet them, diesel engine manufacturers have added diesel particulate filters (DPF) and, more recently, selective catalytic reduction (SCR) systems. As an alternative to diesel buses with these systems, many school districts have looked to other affordable, clean alternatives, and they've found that propane fits the bill.

33 ADVANCED PROPULSION SYSTEMS↗

Preliminary LOCA analysis of the westinghouse small modular reactor using the WCOBRA/TRAC-TF2 thermal-hydraulics code

The Westinghouse Small Modular Reactor (SMR) is an 800 MWt (> 225 MWe) integral pressurized water reactor (iPWR) with all primary components, including the steam generator and the pressurizer located inside the reactor vessel. The reactor core is based on a partial-height 17x17 fuel assembly design used in the AP1000{sup R} reactor core. The Westinghouse SMR utilizes passive safety systems and proven components from the AP1000 plant design with a compact containment that houses the integral reactor vessel and the passive safety systems. A preliminary loss of coolant accident (LOCA) analysis of the Westinghouse SMR has been performed using the WCOBRA/TRAC-TF2 code, simulating a transient caused by a double ended guillotine (DEG) break in the direct vessel injection (DVI) line. WCOBRA/TRAC-TF2 is a new generation Westinghouse LOCA thermal-hydraulics code evolving from the US NRC licensed WCOBRA/TRAC code. It is designed to simulate PWR LOCA events from the smallest break size to the largest break size (DEG cold leg). A significant number of fluid dynamics models and heat transfer models were developed or improved in WCOBRA/TRAC-TF2. A large number of separate effects and integral effects tests were performed for a rigorous code assessment and validation. WCOBRA/TRAC-TF2 was introduced into the Westinghouse SMR design phase to assist a quick and robust passive cooling system design and to identify thermal-hydraulic phenomena for the development of the SMR Phenomena Identification Ranking Table (PIRT). The LOCA analysis of the Westinghouse SMR demonstrates that the DEG DVI break LOCA is mitigated by the injection and venting from the Westinghouse SMR passive safety systems without core heat up, achieving long term core cooling. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Scaling for Nuclear Reactor System: Overview

A scaling analysis is essential for predicting the behavior of a reactor system under various operating conditions, as well as for ensuring safe and reliable experimentation and adequate dataset generation for supporting the system code model development and assessment in accordance with USNRC guidelines 1.203. Testing and modeling can be carried out at various scales, from small test units to full-scale reactors, to validate the predictions produced by the analysis. However, due to the cost and challenges associated with full-scale testing, the nuclear industry uses scaled test facilities—integral effect test (IET) and separate effect test (SET)—to identify potential design issues and optimize the design to ensure regulatory compliance for safer operation and anticipated accident management. In general, IET facilities are non-nuclear thermal hydraulics test facilities. In contrast, SET facilities can be non-nuclear testing (e.g., steam generator, containment, pump system SETs) and nuclear testing (mostly fuel-material irradiation testing). IETs are used to study the system-level thermal-hydraulic behavior of the reactor coolant system (RCS) under different anticipated operational occurrences (AOOs) and design basis accidents (DBAs) such as loss-of-coolant-accident (LOCA) and loss-of-power (i.e., station blackout) and loss-of-flow (i.e., failure of RCS pump). Several LOCA scenarios could happen in reactor DBAs, such as main steam line break (MSLB), SG tube rapture (SGTR), break in direct vessel injection (DVI), and other small breaks LOCA. Scaling analysis determines the appropriate size and operating conditions for the test facility. This involves analyzing the system's thermal-hydraulic behavior at different scales and identifying the key parameters that affect the thermal-hydraulic behavior of the reactor. These key parameters can be identified so that the scaled facility can replicate the expected conditions in a prototypical setting. The scaled facility can simulate the same flow rates, pressure gradients, heat transfer coefficients, and fluid properties as the prototype. Scaling analysis is used to ensure that the results from these tests can be scaled up to predict the behavior of a full-scale prototype with an acceptable range of scaling distortions.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Hydrogen Internal Combustion Engine - Franco Ocampo

This intern poster is personal research on a Hydrogen Internal Combustion Engine. The poster oversees the core problems with the idea of a HICE. The main problem addressed is abnormal combustion which can be a safety hazard firstly, but also mitigate the performance of the engine severely. Solutions include direct fuel injection, alternative cooling systems, and closer attention to valve timing and calibration in relation to fuel delivery.

08 - HYDROGEN↗

Laser ion source for low charge heavy ion beams

For heavy ion inertial fusion application, a combination of a laser ion source and direct plasma injection scheme into an RFQ is proposed. The combination might provide more than 100 mA of singly charged heavy ion beam from a single laser shot. A planned feasibility test with moderate current is also discussed.

74 ATOMIC AND MOLECULAR PHYSICS↗

Drift distance survey in DPIS for high current beam production

In a laser ion source, plasma drift distance is one of the most important design parameters. Ion current density and beam pulse width are defined by plasma drift distance between laser target and beam extraction position. In direct plasma injection scheme (DPIS), which uses a laser ion source and Radio Frequency Quadrupole (RFQ) linac, we can apply relatively higher electric field at the beam extraction due to the unique shape of a positively biased electrode. However, when we aim at very high current acceleration like several tens of mA, we observed mismatched beam extraction conditions. We tested three different ion current at ion extraction region by changing plasma drift distance to study better extraction condition. In this experiment, C{sup 6+} beam was accelerated. We confirmed that the matching condition can be improved by controlling plasma drift distance.

43 PARTICLE ACCELERATORS↗