Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “detector development”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 847 records · Page 47

WE-AB-303-01: FEATURED PRESENTATION: A Dual-Detector Phase-Matched Digital Tomosynthesis (DTS) Imaging Scheme Using Aggregated KV and MV Projections for Intra-Treatment Lung Tumor Tracking

Purpose: To develop a dual-detector phase-matched DTS technique for continuous and fast intra-treatment lung tumor localization. Methods: Tumor localization accuracy of limited-angle DTS imaging is affected by low inter-slice resolution. The dual-detector DTS technique aims to overcome this limitation through combining orthogonally acquired beam’s eye view MV projections and kV projections for intra-treatment DTS reconstruction and localization. To aggregate the kV and MV projections for reconstruction, the MV projections were linearly converted to synthesize corresponding kV projections. To further address the lung motion induced localization errors, this technique uses respiratory phase-matching to match the motion information between on-board DTS and reference DTS to offset the adverse effects of motion blurriness in tumor localization.A study was performed using the CIRS008A lung phantom to simulate different on-board target variation scenarios for localization. The intra-treatment kV and MV acquisition was achieved through the Varian TrueBeam Developer Mode. Four methods were compared for their localization accuracy: 1. the proposed dual-detector phase-matched DTS technique; 2. the single-detector phase-matched DTS technique; 3. the dual-detector 3D-DTS technique without phase-matching; and 4. the single-detector 3D-DTS technique without phase-matching. Results: For scan angles of 2.5°, 5°, 10°, 20° and 30°, the dual-detector phase-matched DTS technique localized the tumor with average(±standard deviations) errors of 0.4±0.3 mm, 0.5±0.3 mm, 0.6±0.2 mm, 0.9±0.4 mm and 1.0±0.3 mm, respectively. The corresponding values of single-detector phase-matched DTS technique were 4.0±2.5 mm, 2.7±1.1 mm, 1.7±1.2 mm, 2.2±0.9 mm and 1.5±0.8 mm, respectively. The values of dual-detector 3D-DTS technique were 6.2±1.7 mm, 6.3±1.2 mm, 5.3±1.3 mm, 2.0±2.2 mm and 1.5±0.5 mm, respectively. And the values of single-detector 3D-DTS technique were 9.7±8.9 mm, 9.8±8.8 mm, 10.0±9.7 mm, 3.9±2.7 mm and 2.2±1.3 mm, respectively. Conclusion: The dual-detector phase-matched DTS technique substantially improves the tumor localization accuracy, which can be applied to real-time intra-treatment lung tumor localization. The research was funded by the National Institutes of Health Grant No. R01-CA184173 and a grant from Varian Medical Systems.

60 APPLIED LIFE SCIENCES↗

Development of a test system for data links of the ATLAS Inner Tracker (ITk) upgrade silicon pixel detector

This contribution introduces a novel test system developed to evaluate the signal transmission quality in high-speed data links for the 2026 Inner Tracker (ITk) upgrade of the ATLAS experiment. Using an FPGA-based data acquisition (DAQ) framework, the setup can run simultaneous Bit Error Rate (BER) tests for up to 64 channels and generate virtual eye diagrams, for qualifying the ∼26k electrical links at the ATLAS ITk data rate of 1.28 Gb/s. The paper includes results from system calibration, yielding its contribution to the measured losses, and preliminary results from tests of prototype and pre-production assemblies of on-detector links of the three ATLAS ITk Pixel subsystems.

47 OTHER INSTRUMENTATION↗

Magnetic Microcalorimeter (MMC) Gamma Detectors with Ultra-High Energy Resolution

The goal of this LCP is to develop ultra-high resolution gamma detectors based on magnetic microcalorimeters (MMCs) for accurate non-destructive analysis (NDA) of nuclear materials. For highest energy resolution, we will introduce erbium-doped silver (Ag:Er) as a novel sensor material, and implement several geometry and design changes to improve the signal-to-noise ratio. The detector sensitivity will be increased by developing arrays of 32 Ag:Er pixels read out by 16 SQUID preamplifiers, and by developing a cryogenic Compton veto to reduce the spectral background. Since best MMC performance requires detector operation at ~10 mK, we will purchase a dilution refrigerator with a base temperature <10 mK and adapt it for MMC operation. The detector performance will be tested with radioactive sources of interest to the safeguards community.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The neutrino mass hierarchy measurement with a neutrino telescope in the Mediterranean Sea: A feasibility study

With the measurement of a non zero value of the θ{sub 13} neutrino mixing parameter, interest in neutrinos as source of the baryon asymmetry of the universe has increased. Among the measurements of a rich and varied program in near future neutrino physics is the determination of the mass hierarchy. We present the status of a study of the feasibility of using a densely instrumented undersea neutrino detector to determine the mass hierarchy, utilizing the Mikheyev-Smirnov-Wolfenstein (MSW) effect on atmospheric neutrino oscillations. The detector will use technology developed for KM3NeT. We present the systematic studies of the optimization of a detector in the required 5–10 GeV energy regime. These studies include new tracking and interaction identification algorithms as well as geometrical optimizations of the detector.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The digital trigger system for the RED-100 detector

The system for forming a trigger for the liquid xenon detector RED-100 is developed. The trigger can be generated for all types of events that the detector needs for calibration and data acquisition, including the events with a single electron of ionization. In the system, a mechanism of event detection is implemented according to which the timestamp and event type are assigned to each event. The trigger system is required in the systems searching for rare events to select and keep only the necessary information from the ADC array. The specifications and implementation of the trigger unit which provides a high efficiency of response even to low-energy events are considered.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Modular Optical PDV System

A modular optical photon Doppler velocimetry (PDV) detector system has been developed by using readily available optical components with a 20-GHz Miteq optical detector into eight channels of single-wide modules integrated into a 3U rack unit (1U = 1.75 inches) with a common power supply. Optical fibers were precisely trimmed, welded, and timed within each unit. This system has been used to collect dynamic velocity data on various physics experiments. An optical power meter displays the laser input power to the module and optical power at the detector. An adjustable micro-electromechanical system (MEMS) optical attenuator is used to adjust the amount of unshifted light entering the detector. Front panel LEDs show the presence of power to the module. A fully loaded chassis with eight channels consumes 45 watts of power. Each chassis requires 1U spacing above and below for heat management. Modules can be easily replaced.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Development of HELIOS/BIPR/PARCS/MCNP6 Computation Route for WWER RPV Neutron Fluence Analysis and Validation Against Ex-Vessel Detector Measurement Data

Here, a computational route was developed for precise calculation of fast neutron fluence on a WWER-type reactor pressure vessel (RPV). The method is based on the transfer of neutronics data from HELIOS-2 lattice calculations and nodal diffusion neutronics data (power, density, and temperature) from BIPR7.1 and PARCS 3.36/PATHS core calculations into a three-dimensional (pinwise axially distributed) fixed neutron source for modeling of transport of fast neutrons from the reactor core to the outer surface of the RPV using MCNP6.2. Validation of the proposed computational method was carried out based on comparative analysis of MCNP6.2-predicted and neutron dosimetry–measured reaction rates [ 54 Fe(n,p) 54 Мn, 93 Nb(n,n') 93 mNb, and 58 Ni(n,р) 58 Со] on the outer surface of the Armenian Nuclear Power Plant (ANPP) Unit 2 RPV. Validation revealed that the MCNP6.2-predicted fast neutron fluence results are very sensitive to the ENDF-B neutron data. Particularly, MCNP6.2 with ENDF/B-VIII.0 significantly underpredicts (20% to 30%) fast neutron fluence while using ENDF/B-VII.1 data overpredicts it. Adding revised beta-released evaluations of 54 Fe, 56 Fe, 57 Fe, and 16 O from the International Nuclear Data Evaluation Network (INDEN) to ENDF/B-VIII.0 allows one to obtain reasonable agreement with measurement results for all types of measured reaction rates.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Observation of 67 keV x-rays with a scintillation detector using proportional-mode silicon avalanche photodiode

We developed a scintillation X-ray detector using a proportional-mode silicon avalanche photodiode (Si-APD). We report a prototype detector using a lead-loaded plastic scintillator mounted on a proportional-mode Si-APD (active area size: 3 mm in diameter), which is operated at a low temperature. Using 67.41 keV X-rays, we could measure pulse-height spectra of scintillation light with a charge-sensitive preamplifier at 20, 0, and −35°C. Time spectra of the X-ray bunch structure were successfully recorded using a wideband and 60-dB-gain amplifier in hybrid-mode operation of the Photon Factory ring. We obtained a better time resolution of 0.51 ns (full width at half-maximum) for the single-bunch X-ray peak at −35°C. We were also able to observe a linear response of the scintillation pulses up to 8 Mcps for input photon rates up to 1.4 × 10{sup 8} photons/s.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Wavelength-Shifting-Fiber Scintillation Detectors for Thermal Neutron Imaging at SNS

We have developed wavelength-Shifting-fiber Scintillator Detector (SSD) with 0.3 m2 area per module. Each module has 154 x 7 pixels and a 5 mm x 50 mm pixel size. Our goal is to design a large area neutron detector offering higher detection efficiency and higher count-rate capability for Time-Of-Flight (TOF) neutron diffraction in Spallation Neutron Source (SNS). A ZnS/6LiF scintillator combined with a novel fiber encoding scheme was used to record the neutron events. A channel read-out-card (CROC) based digital-signal processing electronics and position-determination algorithm was applied for neutron imaging. Neutron-gamma discrimination was carried out using pulse-shape discrimination (PSD). A sandwich flat-scintillator detector can have detection efficiency close to He-3 tubes (about 10 atm). A single layer flat-scintillator detector has count rate capability of 6,500 cps/cm2, which is acceptable for powder diffractometers at SNS.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Estimation of time resolution for DOI-PET detector using diameter 0.2 mm WLS fibers

We are developing the whole-body PET detector with high position resolution (1 mm) and low cost (1 M dollars). Scintillator plates, Wave Length Sifting Fibers and SiPMs are used. In this work, time resolution of our PET detector is estimated. Our detector may also have good time resolution such as a few ps. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Bubble chambers for experiments in nuclear astrophysics

A bubble chamber has been developed to be used as an active target system for low energy nuclear astrophysics experiments. Adopting ideas from dark matter detection with superheated liquids, a detector system compatible with gamma-ray beams has been developed. This detector alleviates some of the limitations encountered in standard measurements of the minute cross sections of interest to stellar environments. While the astrophysically relevant nuclear reaction processes at hydrostatic burning temperatures are dominated by radiative captures, in this experimental scheme we measure the time reversed processes. Such photodisintegrations allow us to compute the radiative capture cross sections when transitions to excited states of the reaction products are negligible. Due to the transformation of phase space, the photodisintegration cross-sections are up to two orders of magnitude higher. The main advantage of the new target-detector system is a density several orders of magnitude higher than conventional gas targets. Also, the detector is virtually insensitive to the gamma-ray beam itself, thus allowing us to detect only the products of the nuclear reaction of interest. The development and the operation as well as the advantages and disadvantages of the bubble chamber are discussed.

79 ASTRONOMY AND ASTROPHYSICS↗

Upgrading FLIR NanoRaider with the next Generation of CdZnTe Detectors. Goal - Integrate VFG detectors into FLIR R200. Advanced Virtual Grid ASIC (AVG-ASIC).

This document presents motivations, goals and the current status of this project; development (fabrication, performance) of position-sensitive virtual Frisch-grid detectors proposed for nanoRaider, an instrument commonly used by nuclear inspectors; ASIC developments for CZT detectors; and the electronics development for the detector prototype..

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Large-volume detector at the Baksan Neutrino Observatory for studies of natural neutrino fluxes for purposes of geo- and astrophysics

At the Baksan Neutrino Observatory (Institute for Nuclear Research, Russian Academy of Sciences, Moscow) deployed in the Caucasus mountains, it is proposed to create, at a depth corresponding to 4760 mwe, a large-volume neutrino detector on the basis of a liquid scintillator with a target mass of 10 kt. The detector in question is intended for recording natural fluxes of neutrinos whose energy may be as low as 100MeV. Neutrino fluxes from various sources are considered in the present study, and the expected effect in the proposed detector is estimated. The detector hat is being developed at the Baksan Neutrino Observatorywill become part of the world network of neutrino detectors for studying natural neutrino fluxes.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Nuclear Structure Studies with Radioactive Ion Beams in the Mass A = 80 Region

An experimental program to measure spectroscopic properties of neutron-rich nuclei in the A = 80 region is underway at the Holifield Radioactive Ion Beam Facility. Our approach has been to get a comprehensive picture of the shell structure in this region by studying a series of properties of low lying states (E(2{sup +}), B(E2), g-factors and quadrupole moments). The beams, instrumentation and techniques developed specifically for this purpose have allowed us to systematically study the behavior of these observables along isotopic and isotonic chains using both stable and radioactive nuclei under almost identical experimental conditions. We have developed many techniques and detectors for in-beam gamma spectroscopy with radioactive ion beams. Most of the detectors can be used individually or in combination. Generally these detector systems have very large efficiencies. We give examples of their use from three recent experiments; namely, Coulomb excitation of n-rich nuclei along the N = 50 shell closure, the static quadrupole moment of the first 2{sup +} in {sup 78}Ge and g-factor measurements of n-rich isotopes near N = 50.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Numerical Investigation of Fluid Flow and Space Charge in Liquid Argon Time Projection Chamber (LArTPC) Detectors

Overview This project focused on developing a high-fidelity numerical framework to simulate the multiphysics environment within Liquid Argon Time Projection Chamber (LArTPC) detectors. The primary objective was to characterize the complex interplay between ion transport, background fluid dynamics, and electric field distortions—a critical factor for the calibration and sensitivity of next-generation High Energy Physics experiments, such as DUNE. Technical Achievements The research successfully yielded a hybrid numerical space-charge solver utilizing a Cell-Centered Finite Volume Method (FVM) for ion transport coupled with a Finite Element Method (FEM) for electric potential. Key accomplishments include: • Verification & Validation: The 3-D solver was rigorously verified against 1-D analytical solutions, demonstrating high numerical accuracy in predicting space-charge-induced field deviations. • Field Distortion Analysis: 3D simulations revealed that space charge effects introduce significant non-uniformities in the electric field. Critically, the research identified that background LAr flow velocities, when comparable to ion drift velocities, markedly exacerbate these distortions. • Technology Transfer: The resulting source code and comprehensive user manuals were successfully transferred to collaborators at Fermilab, providing a portable computational tool for the broader scientific community. Challenges and Future Directions While the space-charge solver achieved all performance metrics, the integrated fluid dynamics modeling encountered convergence challenges stemming from the extreme 200-fold disparity in length scales between the detector's 37 mm inlet pipes and the 8-meter global domain. To address this, the project has identified a clear technical pivot toward Hierarchical Geometric Adaptive Mesh Refinement (HG-AMR). By implementing an h-type refinement strategy with hanging nodes, future iterations of this solver will be capable of resolving localized high-gradient inlet flows without the prohibitive computational costs of regular grids. This advancement, combined with data-driven uncertainty quantification based on MicroBooNE-style calibration, will enable the precise modeling of detector responses in large-scale cryogenic environments where direct measurement remains difficult. Impact The computational tools developed under this award provide a foundation for enhancing the energy resolution and spatial reconstruction of noble liquid detectors. By bridging the gap between theoretical fluid dynamics and experimental field calibration, this work supports the DOE’s mission to advance the frontiers of neutrino physics and dark matter detection.

42 ENGINEERING↗

Next Generation Semiconductor-Based Radiation Detectors Using Cadmium Magnesium Telluride

The primary objective of Phase I was to perform extensive studies on the purification, crystal growth and annealing procedures of CdMgTe to gain a clear understanding of the basic material properties to enable production of detector material with performance comparable to that of CdZnTe. Brimrose utilized prior experience in the growth and processing of II-VI crystals and produced high purity material and good quality single crystals of CdMgTe. Processing techniques for these crystals including annealing, mechanical and chemical polishing, surface passivation and electrode fabrication were developed. Techniques to characterize pertinent electronic characteristics were developed and gamma ray detectors were fabricated. Feasibility of the development of comprehensive defect modeling in this new class of material was demonstrated by our partner research institute SRI International, to compliment the experimental work. We successfully produced a CdMgTe detector that showed 662 keV gamma response with energy resolution of 3.4% (FWHM) at room temperature, without any additional signal correction. These results are comparable to existing CdZnTe (CZT) technology using the same detector size and testing conditions. We have successfully demonstrated detection of gamma-radiation from various isotopes/sources, using CdMgTe thus clearly proving the feasibility that CdMgTe is an excellent, low-cost alternative to CdZnTe.

, CdTe↗

Acoustic detector for fission neutrons

We report here on the progress towards the development of an acoustic neutron detector. The goal is to make a detector that is passive, low cost, and scalable to large areas. We will discuss the potential for this detector to be blind to gamma radiation and the potential for high-efficiency fast neutron imaging. The detector signals are based on the generation of ei ther bubbles or thermo-acoustic shock in a liquid due to energy deposition from a neutron. The interaction of a neutron with a hydrogen rich fluid will primarily be a neutron-hydrogen collision. As they are nearly identical in mass, the most probable scattering event is an elastic event, depositing approximately half of the collision energy into the hydrogen atom. For fission neutrons this energy is in the 1-15 MeV range. The excited hydrogen atom (proton) rapidly thermalizes with the fluid establishing a thermo-acoustic signature which we then monitor with a hydrophone submerged in the fluid. Further, if the fluid is near a phase transition, the de position on energy from the neutron can form a bubble. The formation and collapse of the bubble will create a shockwave which is then detected using a hydrophone submerged in the fluid. Here we will describe: the generation and propagation of acoustic-shock waves, the design and construction of an acoustic detection cell, and the callibration of the cell using photo-acoustic spectroscopy. We will discuss tests preformed using both cosmogenic neutrons and a Californium 252 source, and conclude with a discussion on future implementation of the acoustic neutron detector.

Chandler, David W.↗

Extreme Carrier Depletion and Superlinear Photoconductivity in Ultrathin Parallel-Aligned ZnO Nanowire Array Photodetectors Fabricated by Infiltration Synthesis

Ultrathin semiconductor nanowires enable high-performance chemical sensors and photodetectors, but their synthesis and device integration by standard complementary metal-oxide-semiconductor (CMOS)-compatible processes remain persistent challenges. This work demonstrates fully CMOS-compatible synthesis and integration of parallel-aligned polycrystalline ZnO nanowire arrays into ultraviolet photodetectors via infiltration synthesis, material hybridization technique derived from atomic layer deposition. The nanowire photodetector features unique, high device performances originating from extreme charge carrier depletion, achieving photoconductive on–off ratios of >6 decades, blindness to visible light, and ultralow dark currents as low as 1 fA, the lowest reported for nanostructure-based photoconductive photodetectors. Surprisingly, the low dark current is invariant with increasing number of nanowires and the photodetector shows unusual superlinear photoconductivity, observed for the first time in nanowires, leading to increasing detector responsivity and other parameters for higher incident light powers. Temperature-dependent carrier concentration and mobility reveal the photoelectrochemical-thermionic emission process at grain boundaries, responsible for the observed unique photodetector performances and superlinear photoconductivity. Here, the results elucidate fundamental processes responsible for photogain in polycrystalline nanostructures, providing useful guidelines for developing nanostructure-based detectors and sensors. Lastly, the developed fully CMOS-compatible nanowire synthesis and device fabrication methods also have potentials for scalable integration of nanowire sensor devices and circuitries.

36 MATERIALS SCIENCE↗