Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “decoupling”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 847 records · Page 47

Enhancing Cyber Resilience of Networked Microgrids using Vertical Federated Reinforcement Learning

This paper presents a novel federated reinforcement learning (Fed-RL) methodology to inject sufficient resiliency into the operations of the network of microgrids. We consider adversarial actions to the voltage and power control loop reference signals at the grid forming (GFM) inverters in the microgrids which are essential to integrate renewable resources. Therefore, we formulate a resilient reinforcement learning training setup that uses these adversarial injections to generate episodic trajectories and train the RL agents to alleviate their impact on performance. To circumvent the concerns about data-sharing and privacy for different owners of the microgrids in the networked setting, we bring in the aspects of the federated operation to propose novel Fed-RL algorithms. As the dynamics of each microgrid are coupled due to electrical interlinks, the conventional federated RL approaches using decoupled independent environments are not applicable, which leads us to propose a multi-agent vertically federated variation of actor-critic algorithms, namely federated soft actor-critic (FedSAC). We have performed numerical simulations on an IEEE 123-bus benchmark test feeder with three microgrids by creating a customized simulation setup by encapsulating the microgrid dynamic simulations in GridLAB-D/HELICS co-simulation platform with the OpenAI Gym environment and validated the proposed resilient and secured learning methodology.

Artificial Intelligence (AI), reinforcement learni↗

PV Degradation - Mounting & Temperature

Several studies have found indications that PV degradation may increase in hotter climates. We show in this paper that degradation does correlate to higher module temperatures, but that these temperatures are significantly affected by the module mounting and. The mechanisms of degradation vary with module technology and quality. Using data from different HIT module installations we were able to extract an activation energy that is consistent with hydrogen passivation layer degradation. In addition, we show that low degradation in hot climates can be achieved for Al-BSF technology if properly installed to reduce heat transfer in order to thermally decouple the modules from the roof. We also found that monofacial and bifacial PERC module degradation is in line with historical degradation rates of Al-BSF.

14 SOLAR ENERGY↗

Online Event Detection in Synchrophasor Data with Graph Signal Processing

Online detection of anomalies is crucial to enhancing the reliability and resiliency of power systems. We propose a novel data-driven online event detection algorithm with synchrophasor data using graph signal processing. In addition to being extremely scalable, our proposed algorithm can accurately capture and leverage the spatio-temporal correlations of the streaming PMU data. This paper also develops a general technique to decouple spatial and temporal correlations in multiple time series. Finally, we develop a unique framework to construct a weighted adjacency matrix and graph Laplacian for product graph. Case studies with real-world, large-scale synchrophasor data demonstrate the scalability and accuracy of our proposed event detection algorithm. Compared to the state-of-the-art benchmark, the proposed method not only achieves higher detection accuracy but also yields higher computational efficiency.

Event detection↗

Reverse and Forward Engineering of Local Voltage Control in Distribution Networks

The increasing penetration of renewable and distributed energy resources in distribution networks calls for real-time and distributed voltage control. As such, in this paper we investigate local Volt/VAR control with a general class of control functions, and show that the power system dynamics with non-incremental local voltage control can be seen as a distributed algorithm for solving a well-defined optimization problem (reverse engineering). The reverse engineering further reveals a fundamental limitation of the non-incremental voltage control: the convergence condition is restrictive and prevents better voltage regulation at equilibrium. This motivates us to design two incremental local voltage control schemes based on the subgradient and pseudo-gradient algorithms respectively for solving the same optimization problem (forward engineering). The new control schemes decouple the dynamical property from the equilibrium property, and have much less restrictive convergence conditions. This work presents another step towards developing a new foundation—network dynamics as optimization algorithms—for distributed real-time control and optimization of future power networks.

42 ENGINEERING↗

Fault isolation and fault-tolerant control for Takagi-Sugeno fuzzy time-varying delay stochastic distribution systems

A fault isolation, estimation, and fault-tolerant control (FTC) scheme for nonlinear time-varying delay stochastic distribution control systems was presented in this paper. The Takagi-Sugeno fuzzy model was adopted to approach the nonlinear dynamics of time-varying delay systems. According to the output equivalence principle and Laplace transformation, an augmented state vector was given to solve the time-varying delay problem. When multiple actuator faults and interference occur simultaneously, fault detection, isolation and fault estimation was designed to obtained the fault information. To decouple faults and obtain the value and location information of the fault, the system was separated into two parts through the designed multiple conversion matrices, in which one subsystem was only affected by one actuator fault. This has simplified the design of fault isolation and estimation. A adaptive observer for fault estimation was given. Then, fault information such as the time, location, and size was determined. The observer gain matrices were calculated using linear matrix inequality (LMI). When a fault was detected and diagnosed, a FTC algorithm was devised using the proportional-integral control scheme to compensate the fault as much as possible. It has been shown that even if multiple faults actuator occurred simultaneously, the FTC controller still ensured the output probability density function of the system traced the desired probability density function when a fault occurred. Finally, the expected results were obtained through the simulation example, which confirmed the effectiveness of the method.

42 ENGINEERING↗

Versatile High-Gain Low-Noise Readout ASIC for Silicon Microstrip Tracking Detectors

This work presents Turpial, a custom-designed low- power front-end readout ASIC for microstrip silicon sensors. Implemented in 130 nm CMOS technology, the chip integrates 64 identical readout channels, each including a configurable charge-sensitive amplifier, a bipolar pulse shaper, a 32-sample 50 Msps analog memory, and a 12-bit RC-hybrid SAR ADC operating at 1 Msps. To satisfy the target power budget of 5 mW per channel, the architecture employs a time-decoupled readout scheme in which fast transient signals are first captured in the analog memory and subsequently digitized at a lower rate. Turpial supports a wide dynamic range from 1 kℎ+ to 1 Mℎ+ while maintaining low noise performance, targeting an equivalent noise charge (ENC) below 200 𝑒−including the sensor, and providing a maximum gain of 1500 mV/fC. A digital block manages slow control, data acquisition, and data serialization through dual CML 300 Mb/s serializers. In addition, an on-chip reference circuit, based on a sub-1 V bandgap reference and an integrated LDO regulator, eliminates the need for external reference circuitry. Experimental results demonstrate that both the individual building blocks and the fully integrated ASIC meet the design specifications.

Hernandez, Hugo [Stanford University] (ORCID:00000↗

Enabling Scalable and Extensible Memory-mapped Datastores in Userspace

Exascale workloads are expected to incorporate data-intensive processing in close coordination with traditional physics simulations. These emerging scientific, data-analytics and machine learning applications need to access a wide variety of datastores in flat files and structured databases. Programmer productivity is greatly enhanced by mapping datastores into the application process's virtual memory space to provide a unified “in-memory” interface. Currently, memory mapping is provided by system software primarily designed for generality and reliability. However, scalability at high concurrency is a formidable challenge on exascale systems. Also, there is a need for extensibility to support new datastores potentially requiring HPC data transfer services. In this article, we present UMap , a scalable and extensible userspace service for memory-mapping datastores. Furthermore, through decoupled queue management, concurrency aware adaptation, and dynamic load balancing, UMap enables application performance to scale even at high concurrency. We evaluate UMap in data-intensive applications, including sorting, graph traversal, database operations, and metagenomic analytics. Our results show that UMap as a userspace service outperforms an optimized kernel-based service across a wide range of intra-node concurrency by 1.22-1.9 × . We performed two case studies to demonstrate UMap 's extensibility. First, a new datastore residing in remote memory is incorporated into UMap as an application-specific plugin. Second, we present a persistent memory allocator Metall built atop UMap for unified storage/memory.

97 MATHEMATICS AND COMPUTING↗

Design and Performance Characterization of RADICAL-Pilot on Leadership-Class Platforms

Many extreme scale scientific applications have workloads comprised of a large number of individual highperformance tasks. The Pilot abstraction decouples workload specification, resource management, and task execution via job placeholders and late-binding. As such, suitable implementations of the Pilot abstraction can support the collective execution of large number of tasks on supercomputers. We introduce RADICAL-Pilot (RP) as a portable, modular and extensible Pilot enabled runtime system. We describe RP's design, architecture and implementation. We characterize its performance and show its ability to scalably execute workloads comprised of tens of thousands heterogeneous tasks on DOE and NSF leadership-class HPC platforms. Specifically, we investigate RP's weak/strong scaling with CPU/GPU, single/multi core, (non)MPI tasks and python functions when using most of ORNL Summit and TACC Frontera. RADICAL-Pilot can be used stand-alone, as well as the runtime for third-party workflow systems.

97 MATHEMATICS AND COMPUTING↗

funcX: Federated Function as a Service for Science

Here, funcX is a distributed function as a service (FaaS) platform that enables flexible, scalable, and high performance remote function execution. Unlike centralized FaaS systems, funcX decouples the cloud-hosted management functionality from the edge-hosted execution functionality. funcX's endpoint software can be deployed, by users or administrators, on arbitrary laptops, clouds, clusters, and supercomputers, in effect turning them into function serving systems. funcX's cloud-hosted service provides a single location for registering, sharing, and managing both functions and endpoints. It allows for transparent, secure, and reliable function execution across the federated ecosystem of endpoints-enabling users to route functions to endpoints based on specific needs. funcX uses containers (e.g., Docker, Singularity, and Shifter) to provide common execution environments across endpoints. funcX implements various container management strategies to execute functions with high performance and efficiency on diverse funcX endpoints. funcX also integrates with an in-memory data store and Globus for managing data that may span endpoints. We motivate the need for funcX, present our prototype design and implementation, and demonstrate, via experiments on two supercomputers, that funcX can scale to more than 130000 concurrent workers. We show that funcX's container warming-aware routing algorithm can reduce the completion time for 3,000 functions by up to 61% compared to a randomized algorithm and the in-memory data store can speed up data transfers by up to 3x compared to a shared file system.

97 MATHEMATICS AND COMPUTING↗

Busbar Design and Optimization for Voltage Overshoot Mitigation of a Silicon Carbide High-Power Three-Phase T-Type Inverter

The silicon carbide (SiC) devices have faster switching speed than that of the conventional silicon (Si) devices, which however may cause excessive device voltage overshoot. Larger gate resistance can help to restrain the overshoot, it however slows down the switching speed and increases switching losses. There are other methods that can mitigate the voltage overshoot, e.g., using low-inductance busbars, adding snubber circuits, etc. In this article, the busbar design for a 250-kW SiC three-level T-type inverter is investigated. The current commutation loops (CCLs) are first analyzed using a single-phase equivalent circuit. Then the detailed busbar design methods, especially a 3-D busbar design concept, are proposed to select the optimal stacking order for the multilayer laminated busbar and to address constraints posed by the physical terminal arrangements of SiC modules and dc-link capacitors. The stray inductance in each CCL is extracted via a finite element analysis and validated on the actual inverter busbar prototypes using an impedance analyzer. To further minimize the busbar stray inductance, a hybrid busbar structure with printed circuit board based buffer circuit using high-frequency decoupling capacitors is designed and evaluated in this article. Lastly, the effectiveness of the designed busbars as well as the buffer circuit are validated using experimental studies.

42 ENGINEERING↗

A Field Enhancement Integration Design Featuring Misalignment Tolerance for Wireless EV Charging Using LCL Topology

This article proposes a magnetic integration design for EV wireless power transfer (WPT) systems, where the compensation and transmitting coils overlap one on top of the other to share the ferrite layer without any decoupling consideration. The magnetic field generated by both the compensation and transmitting coils are exploited to transfer power. To this end, a compensation method is proposed to enable magnetic field enhancement without any reactive power flow between the compensation and the transmitting coils, and to achieve input zero phase angle and constant current output. In addition, an efficient finite element analysis-based coil optimization algorithm is proposed to improve the coil misalignment tolerance on the horizontal plane, in which a reversely connected inner coil is used to stabilize the system output under misalignment conditions. Analytical and simulation results confirm transmission flux density enhancement and reduced leakage field characteristics of the proposed coil design. Finally, a scaled-down WPT prototype is built and tested to verify the performance and effectiveness of the design. The proposed design achieves 91.17% efficiency and misalignment tolerance up to 200 mm in any XY-direction while maintaining the power transfer and its efficiency. The results of this work provide insights into magnetic integration design of high-order compensation topologies featuring higher compactness, less ferrite usage, magnetic field enhancement, and misalignment tolerance for WPT systems.

42 ENGINEERING↗

7.2 kV Three-Port SiC Single-Stage Current-Source Solid-State Transformer With 90 kV Lightning Protection

This article proposes a multiport modular single-stage current-source solid-state transformer (SST) for applications like photovoltaic, energy storage integration, electric vehicle fast charging, data center, etc. The 7.2 kV 50 kVA current-source SST consists of five input-series output-parallel modules, each based on 3.3 kV SiC reverse-blocking MOSFET-plus-diode modules. The proposed SST has some unique features. First, compared to the voltage-source or matrix converter-based SSTs, the current-source SST has a unique advantage of single-stage isolated AC/DC or AC/AC conversion with an inductive DC link, but no medium-voltage (MV) AC experiments have been reported. This article for the first time demonstrates MV AC current-source SST up to 7.5 kV peak. Second, the multiport SST has a buffer port for active power decoupling (APD) or energy storage integration. The double-line-frequency power ripple from single-phase AC grid normally results in a large capacitor size in MV SSTs. The APD scheme is proposed in MV applications for the first time to enable a reduced DC link and the electrolytic capacitor-less SST with high reliability. Third, as a direct grid-connected converter without line-frequency transformer, insulation and protection are critical. A medium-frequency transformer design passes 55 kV basic-insulation level (BIL) and 60 kV high potential dielectrics withstand test with only 0.09% leakage inductance. Importantly, a lightning protection scheme is presented to protect the SST itself from 90 kV BIL impulse. Fourth, the proposed current-source SST topology is a modular soft-switching solid-state transformer (M-S4T) with full-range zero-voltage switching and controlled dv/dt for low electromagnetic interference. Furthermore, these concepts are verified in a three-port M-S4T prototype with forced oil cooling under single-module, stacked-module, steady-state, and dynamic operations.

14 SOLAR ENERGY↗

PCB-on-DBC GaN Power Module Design with High-Density Integration and Double-Sided Cooling

Lateral gallium nitride (GaN) high-electron-mobility transistors (HEMTs) present better electrical characteristics compared to silicon or silicon carbide devices such as high switching speed and low gate charge, but also present additional challenges on the module design. Here, this paper discusses a high-density GaN power module with double-sided cooling, low inductance, on-package decoupling capacitors, and integrated gate drivers. The GaN dies as well as the gate drive are sandwiched between the printed circuit board (PCB) and direct bonded copper (DBC) substrate to achieve compact loop and double-sided cooling effect. Design considerations and thermal performance are analyzed. A module assembly procedure is presented utilizing the layer-by-layer attachment process. Finally, a 2.7 cm x 1.8 cm half-bridge GaN power module is fabricated and tested, achieving a low power-loop inductance of 1.03 nH, and the overshoot voltage of the switching waveform is less than 5% under a 400-V/25-A double-pulse test. The thermal resistance is 0.32 K/W, verified by simulation and experimental results. The design and assembly process can be generalized and applied to high power applications to achieve high power density and high performance.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Implementation of a Doppler-Free Saturation Spectroscopy (DFSS) Diagnostic for Helicon Wave Electric Field Vector Measurement in Edge Plasma in DIII-D

A laser-based technique known as Doppler-free saturation spectroscopy (DFSS) has been designed, fabricated, and installed on the DIII-D National Fusion Facility to measure the helicon wave electric field vector in the edge plasma. These experimental measurements quantify phenomena resulting in decreased current drive efficiency due to wave/edge plasma interactions. This implementation of DFSS on DIII-D is the first of its kind on a tokamak and thus presents unique engineering challenges, including integration of the system onto an existing multidiagnostic port flange without impacts to system serviceability, as well as maintaining precise laser alignment over a 2-m distance during disruptions and thermal drift of the vessel. Further, these challenges were resolved using innovative design approaches such as a novel decoupled shutter system to facilitate serviceability of the in-vessel mirror assemblies without the need for personnel vessel entry, as well as an ex-vessel piezo-mirror-based optical system for laser beam shaping and real-time steering of the measurement location. The solutions to these engineering challenges were demonstrated during the successful installation and operation of these diagnostic components during the 2022 DIII-D vent and subsequent experimental campaign.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Energy-Storage Modeling: State-of-the-Art and Future Research Directions

Given its physical characteristics and the range of services that it can provide, energy storage raises unique modeling challenges. This paper summarizes capabilities that operational, planning, and resource-adequacy models that include energy storage should have and surveys gaps in extant models. Existing models that represent energy storage differ in fidelity of representing the balance of the power system and energy-storage applications. Modeling results are sensitive to these differences. The importance of capturing chronology can raise challenges in energy-storage modeling. Some models ‘decouple’ individual operating periods from one another, allowing for natural decomposition and rendering the models relatively computationally tractable. Energy storage complicates such a modeling approach. Improving the representation of the balance of the system can have major effects in capturing energy-storage costs and benefits.

25 ENERGY STORAGE↗

Limitations of Fault-Tolerant Quantum Linear System Solvers for Quantum Power Flow

Quantum computers hold promise for solving problems intractable for classical computers, especially those with high time or space complexity. Practical quantum advantage can be said to exist for such problems when the end-to-end time for solving such a problem using a classical algorithm exceeds that required by a quantum algorithm. Reducing the power flow (PF) problem into a linear system of equations allows for the formulation of quantum PF (QPF) algorithms, which are based on solving methods for quantum linear systems such as the Harrow-Hassidim-Lloyd (HHL) algorithm. Speedup from using QPF algorithms is often claimed to be exponential when compared to classical PF solved by state-of-the-art algorithms. Here, we investigate the potential for practical quantum advantage in solving QPF compared to classical methods on gate-based quantum computers. Notably, this paper does not present a new QPF solving algorithm but scrutinizes the end-to-end complexity of the QPF approach, providing a nuanced evaluation of the purported quantum speedup in this problem. Our analysis establishes a best-case bound for the HHL-based quantum power flow complexity, conclusively demonstrating that the HHL-based method has higher runtime complexity compared to the classical algorithm for solving the direct current power flow (DCPF) and fast decoupled load flow (FDLF) problem. Notably, our analysis and conclusions can be extended to any quantum linear system solver with rigorous performance guarantees, based on the known complexity lower bounds for this problem. Additionally, we establish that for potential practical quantum advantage (PQA) to exist it is necessary to consider DCPF-type problems with a very narrow range of condition number values and readout requirements.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Online Optimization for Networked Distributed Energy Resources With Time-Coupling Constraints

This paper proposes a Lyapunov optimization-based online distributed (LOOD) algorithmic framework for active distribution networks (ADNs) with numerous photovoltaic inverters and inverter air conditionings (IACs). In the proposed scheme, ADNs can track an active power setpoint reference at the substation in response to transmission-level requests while concurrently minimizing the social utility loss and ensuring the security of voltages. Conventional distributed optimization methods are rarely feasible to track the optimal solutions in fast variable environments using a fine-grained sampling interval where the underlying optimization problem evolves with the iterations of the algorithms. In contrast, based on the framework of online convex optimization (OCO), the developed approach uses a distributed algebraic update to compute the next round decisions relying on the current feedback of measurements. Notably, the time-coupling constraints of IACs are decoupled for online implementation with Lyapunov optimization technique. An incentive scheme is tailored to coordinate the customer-owned assets in lieu of the direct control from network operators. Optimality and convergency are characterized analytically. Finally, we corroborate the proposed method on a modified version of 33-node test feeder. Benchmark tests show that the proposed method is computationally and economically efficient, and outperforming existing algorithms.

active distribution networks↗

Deep Reinforcement Learning based Model-free On-line Dynamic Multi-Microgrid Formation to Enhance Resilience

Multi-microgrid formation (MMGF) is a promising solution for enhancing power system resilience. This paper proposes a new deep reinforcement learning (RL) based model-free on-line dynamic MMGF scheme. Additionally, the dynamic MMGF problem is formulated as a Markov decision process, and a complete deep RL framework is specially designed for the topologytransformable micro-grids. In order to reduce the large action space caused by flexible switch operations, a topology transformation method is proposed and an action-decoupling Q-value is applied. Then, a convolutional neural network (CNN) based multi-buffer double deep Q-network (CM-DDQN) is developed to further improve the learning ability of the original DQN method. The proposed deep RL method provides real-time computing to support the on-line dynamic MMGF scheme, and the scheme handles a long-term resilience enhancement problem using an adaptive on-line MMGF to defend changeable conditions. The effectiveness of the proposed method is validated using a 7-bus system and the IEEE 123-bus system. The results show strong learning ability, timely response for varying system conditions and convincing resilience enhancement.

24 POWER TRANSMISSION AND DISTRIBUTION↗