At least 847 records · Page 47

Anomalous magnetic properties of CaRuO3 probed by AC and DC magnetic measurements and by low Ti impurity doping

Calcium ruthenate (CaRuO3) is widely believed to be located close to a quantum critical point due to the strong non-Fermi-liquid behavior expressed in the temperature dependence of electronic transport, specific heat, optical conductivity, etc. However, the corresponding anomalous behavior, marking crossover temperature regimes in the magnetic response of CaRuO3, is still lacking. Here we report detailed AC and DC magnetic susceptibility measurements of CaRuO3 and CaR u0.97 Ti 0.03 O3. The AC magnetic susceptibility measurements of CaRuO3 show a slight dependence on the frequency of AC magnetic field below ∼40K, and an additional subtle change of curvature around 12 K. We interpret these results as a critical slowing down of spin fluctuations towards T = 0 K. We confirm these observations by magnetic measurements of CaRu0.97 Ti 0.03 O3, which show a pronounced magnetic response corresponding to the above temperatures.

60 APPLIED LIFE SCIENCES↗

dc conductivity of two-temperature warm dense gold

Using recently obtained ac conductivity data we have derived dc conductivity together with free electron density and electron momentum relaxation time in two-temperature warm dense gold with energy density up to 4.1 MJ/kg ( 0.8 × 10 11 J / m 3 ). The derivation is based on a Drude interpretation of the dielectric function that takes into account contributions of intraband and interband transitions as well as atomic polarizability. Overall, the results provide valuable benchmarks for assessing the extended Ziman formula for electrical resistivity and an accompanying average atom model.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Plasma Currents and Electron Distribution Functions under a dc Electric Field of Arbitrary Strength

The currents induced by arbitrarily strong dc electric fields in plasma and the evolution of electron distributions have been studied by Fokker-Planck simulations. We find that the electron distributions evolve distinctly under different fields; especially, the electron distribution is well represented by the sum of a stationary and drifting Maxwellian at the moderate field. A set of hydrodynamiclike equations, similar to Spitzer's but without the weak-field limit, is given for calculating the current. It is more suitable for application in hybrid particle-in-cell simulations and may extend plasma transport theory in models that do not employ a kinetic description of the electrons.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Structural Properties of Complex Plasmas in a Homogeneous dc Discharge

We report on the first three-dimensional (3D) complex plasma structure analysis for an experiment that was performed in an elongated discharge tube in the absence of striations. The low frequency discharge was established with 1 kHz alternating dc current through a cylindrical glass tube filled with neon at 30 Pa. The injected particle cloud consisted of monodisperse microparticles. A scanning laser sheet and a camera were used to determine the particle position in 3D. The observed cylindrical-shaped particle cloud showed an ordered structure with a distinct outer particle shell. The observations are in agreement with performed molecular dynamics simulations.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Design of the Low-energy DC Gun for Field-emission Cathode Investigation

A DC electron source test-stand to explore fieldemission from various cathodes has been designed. The design also includes a provision to allow for laser-triggered field emission using a femtosecond laser source. The gun is instrumented to measure the beam transverse distribution, the transverse emittance, and I

43 PARTICLE ACCELERATORS↗

A Novel Three-Phase Oak Ridge AC / DC Converter for Wireless EV Charger Applications

In this paper, a novel three-phase converter is proposed for ac to dc wireless power transfer (WPT) systems for electric vehicle (EV) charging applications. The proposed innovative solution, called as Oak Ridge Converter, reduces the design complexity and cost by eliminating the front-end converter stage compared to the conventional systems. Additionally, grid side requirements can be met with the proposed creative concept. In this concept, the three-phase single-stage Oak Ridge Converter directly converts the 60 Hz grid frequency into high-frequency voltage and utilizes hybrid grid-source and high-frequency to realize power transfer from AC source through resonant network and coupling coils to the battery load. Simulation validation of the proposed three-phase system is currently being carried on and the results will be will be provided to validate the theoretical studies with the input of 277 VAC,RMS and output of 675 VDC at 35 kW power. The system current total harmonic distortion (THD) is measured 5% with a power factor (PF) of 0.98 and overall hardware development of the system that will be used for experiments is presented.

Asa, Erdem↗

A 1MHz Oak Ridge AC / DC Converter for UAV Contactless Charger Implementation

In this paper, a 1 MHz single-phase Oak Ridge Converter (ORC) AC/DC wireless power transfer (WPT) system is introduced for unmanned air vehicle (UAV) charging applications. The proposed advanced solution eliminates the design, weight, volume, and the cost of the power factor correcting (PFC) front-end rectifier compared to the conventional practices. Additionally, grid power quality requirements can be achieved with the presented innovative idea. With this method, single stage WPT primary side uses the hybrid grid frequency and high frequency (60 Hz and 1 MHZ) from ac source through the coupler coils and to UAV battery with GaN FETs. Experimental results of the single-phase system is presented to confirm the mathematical analyses with the source voltage of 110 VAC, RMS and output voltage of 40 VDC at 1 kW power with 6 inches air gap between couplers. The primary coupler consists of a ferrite-backed single-turn coil with a radius of 1.5 ft, and the secondary coupler is made with an air-core single-turn coil with radius of 1.2 ft. The system overall ac to dc efficiency is measured 77 % acquiring 0.99 power factor (PF) and 3.3 % current total harmonic distortion (THD) at 1 kW power.

Asa, Erdem↗

Automated qualification and analysis of protective spark gaps for DC accelerators

Protective spark gaps are used in the high voltage multiplier column of a 3 MeV DC Accelerator to prevent excessive voltage build-ups. Precise gap of 5 mm is maintained between the electrodes in these spark gaps for obtaining 120 kV± 5 kV in 6 kg/cm{sup 2} SF{sub 6} environment which is the dielectric medium. There are 74 such spark gaps used in the multiplier. Each spark gap has to be qualified for electrical performance before fitting in the accelerator to ensure reliable operation. As the breakdown voltage stabilizes after a large number of sparks between the electrodes, the qualification process becomes time consuming and cumbersome. For qualifying large number of spark gaps an automatic breakdown analysis setup has been developed. This setup operates in air, a dielectric medium. The setup consists of a flyback topology based high voltage power supply with maximum rating of 25 kV. This setup works in conjunction with spark detection and automated shutdown circuit. The breakdown voltage is sensed using a peak detector circuit. The voltage breakdown data is recorded and statistical distribution of the breakdown voltage has been analyzed. This paper describes details of the diagnostics and the spark gap qualification process based on the experimental data. (author)

43 PARTICLE ACCELERATORS↗

Optical signatures of discharges in parallel coupled DC accelerator

Parallel coupled voltage multiplier based accelerator topologies offer advantages of better regulation and ripple compared to their series coupled counterparts for Industrial electron beam accelerators. During conditioning and operation these systems undergoes various types of electrical discharges. The discharge can be a direct spark over from the high voltage terminal to ground through SF{sub 6} insulation, vacuum breakdown in the accelerating tube maintained in the order of 10{sup -7} mbar pressure, or local discharge between corona guards which are used to couple RF power to the multiplier. There could be discharges in between dynodes of the accelerating tube. As the inter electrode discharges do not reflect in load current, detection of these conditions becomes very difficult. Optical discharge detection methods can be used effectively in this situation. Photo multiplier based optical discharge detection has been deployed in a 3 MeV DC accelerator. Characteristics of the optical signal received during conditioning phase have been presented in this paper. (author)

43 PARTICLE ACCELERATORS↗

Flexible Intelligent Real-time dc-ac grid Emulator (FIRE): Power Electronic Hardware-in-the-Loop (PE-HIL) Amplifier

Grid modernization efforts are leading to increased penetration of power electronics in the existing alternating current (ac) bulk power systems (BPS). Some examples of power electronics based applications that are being developed in BPS include high-voltage direct current (HVdc) systems, renewable generation systems, energy storage systems, and others. One of the requirements to succeed in the goals of grid modernization (like increased efficiency and reliability) is to setup a platform that can evaluate basic building blocks of such systems. For example, the basic building block of a modular multilevel converter (MMC)-based HVdc system is a submodule (SM). The evaluation platform will provide means to innovate new SM circuit architectures, new semiconductor devices in the SM, new gate-drivers, new controllers, and others. The flexible intelligent real-time dc-ac grid emulator (FIRE) platform incorporates the evaluation capability to evaluate the basic building blocks. The FIRE platform incorporates this evaluation capability through the power electronic hardware-in-the-loop (PE-HIL) concept. The PE-HIL for MMC-HVdc system can evaluate SMs in the MMC. In this paper, the design of amplifier required to perform PE-HIL simulation is presented. Experimental results of the amplifier and the simulation results of the PE-HIL concept utilizing the amplifier are presented.

Debnath, Suman↗

DC Microgrids Under Denial of Service Attacks: Feasibility and Stability Issues

Distributed control has been extensively studied for a DC microgrid to coordinate multiple grid assets where each asset can generate its own control decisions based on communications within its neighborhood. Nevertheless, such a control strategy usually has a strong dependence on active information exchange and needs to always maintain a pre-determined communication graph. This makes it vulnerable to cyber attacks, especially denial of service (DoS) attacks that block communication channels that effectively change the communication graph. In this paper, we study two potential impacts of DoS attacks: the inability to maintain steady-state and dynamical generation-demand balance, i.e. the feasibility and stability issues. We develop a mathematical model to describe the cyber-induced system steady-state and dynamical performance. The model reveals the impacts of DoS attacks and enables formal analysis. Case studies are shown to verify the proposed work.

41 EE - Solar Energy Technologies Office (EE-4S)↗

Controller Hardware-in-the-Loop Modeling and Operation of a High-Power DC Charging Hub

High-power charging (HPC) concept will be a critical enabler for the wide-scale adoption and integration of electric vehicles (EVs). HPC hubs will have a significant impact on achieving this goal, particularly when considering the charging requirements of next-generation medium and heavy-duty vehicles (MD/HD) used in various vocational scenarios. This emphasizes the significance of evaluating and confirming the technical planning and multi-level operation of HPC hubs through modeling, protocol implementation, and simulation before hardware demonstration. The focus of this study is to develop the architecture, modeling, communication, and real-time controller hardware-in-the-loop (C-HIL) simulation of HPC hubs using the DC distribution system approach. Specifically, this work demonstrates the practical implementation of a custom Smart Energy Management System (SEMS) for a real-time C-HIL HPC hub simulation using the Open Charge Point Protocol (OCPP) for communication. OCPP is implemented on the Node-Red framework and the custom controller is executed in Python. We developed a rule-based controller to demonstrate the proposed approach.

ADVANCED PROPULSION SYSTEMS↗

SCR-based Medium Voltage DC Solid-State Circuit Breaker

This paper describes a medium voltage solid-state circuit breaker (SSCB) based on SCR technology, featuring short fault-interruption time and a minimal turn-off auxiliary circuit. The SSCB design incorporates a specialized SCR and a commutation circuit designed with an objective to reduce the required SCR hold-off/turn-off time, tq, which primarily determines the fault interruption duration. To validate the design, simulation analysis is presented, and a 1.5 kV 300 A SSCB prototype has been built and tested. The results confirm the effectiveness of the proposed design philosophy demonstrating the SSCB's ability to interrupt a 200 A load current in less than 50 μs. The proposed SCR-based SSCB has been developed for DC applications but is equally applicable to AC applications.

Kandula, Prasad [ORNL] (ORCID:0000000174017284)↗

A Low Voltage DC Power Electronic Hub to Support Buildings

This paper presents the communication, control, and architecture, for a low voltage (nominal 480V) hybrid AC/DC microgrid for supporting small commercial buildings with critical data center loads. The proposed system is based on a dc-power electronic hub (PEH) that seamlessly integrates renewable energy resources, energy storage, and back-up generation to support commercial building economical energy management and reliability. This PEH concept provides a parallelization of critical power to the commercial and industrial buildings leading to increased efficiency and reliability compared to traditional uninterruptable power supplies. The demonstration of the proposed PEH architecture and controls is conducted through a controller hardware in the loop validation.

Starke, Michael↗

Development of a DC Fast Charging Station Model for Use with EV Infrastructure Projection Tool

The deployment of public charging infrastructure networks has been a major factor in enabling electric vehicle (EV) technology transition, and must continue to support the adoption of this technology. DC fast charging (DCFC) increases customer convenience by lowering charging time, enables long-distance EV travel, and could allow the electrification of high-mileage fleets. Yet, high capital costs and uneven power demand have been major challenges to the widespread deployment of DCFC stations. There is a need to better understand DCFC stations' loading, utilization, and customer service quality (i.e. queuing time, charging duration, and queue length). This study aims to analyze these aspects using one million vehicle-days of travel data within the Columbus, OH, region. Monte Carlo analysis is carried out in three types of areas - urban, suburban, and rural- to quantify the effect of uncertain parameters on DCFC station loading and service quality.

25 ENERGY STORAGE↗

A Control Strategy for Improving Resiliency of an DC Fast Charging EV System

As DC fast charging electric vehicle (EV) infrastructure continues to expand, potential challenges loom. One issue is the potential for EV charger outages due to electrical grid voltage transients. Today, EV chargers are expected to disconnect under a severe voltage sag (below 70%) which reduces electric vehicle charging infrastructure resilience. This work proposes a droop-control solution to ride-through voltage sags and maintain operation. The control solution is presented in a controller hardware in the loop platform.

Starke, Michael↗

Predictive Control to Further Reduce DC-Link Capacitor Current Stress for Segmented Inverter

Two three-phase interleaved inverters have been used in traction drive applications to reduce the current stress in a DC link capacitor bank. In such applications, either carrier-based or space vector modulation is used to select the optimum switching sequences, and the results show 50% less capacitor current than that of a single three-phase inverter. The switching state selection process for this inverter is tedious, and there has been no research to find the optimal switching state. To overcome this challenge, this research employed a simple finite set model predictive control to select the optimum switching sequence for a dual three-phase interleaved topology, called a segmented inverter. The results show that the predictive control algorithm can provide a simple solution and can reduce the current stress by 27% compared with traditional modulation techniques for the segmented inverters.

Ribeiro, Pedro↗