Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “count data”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 847 records · Page 47

Coupled Approximation of U.S. Driving Speed and Volume Statistics Using Spatial Conflation and Temporal Disaggregation

The advent of mobile devices with embedded global positioning systems has allowed commercial providers of real-time traffic data to develop highly accurate estimates of network-level vehicle speeds. Traffic speed data have far outpaced the availability and accuracy of real-time traffic volume information. Limited to a relatively small number of permanent and temporary traffic counters in any city, traffic volumes typically only cover a handful of roadways with inconsistent temporal resolution. This work addressed this data gap by coupling a commercial dataset of typical traffic speeds (by roadway and time of week) from TomTom to the U.S. FHWA's Highway Performance Monitoring System database of annual average daily traffic (AADT) counts by roadway. This work is technically novel in its solution for establishing a national crosswalk between independent network geometries using spatial conflation and big data techniques. The resulting product is a national dataset providing traffic speed and volume estimates under typical conditions for all U.S. roadways with AADT values.

30 DIRECT ENERGY CONVERSION↗

Development of a New Chelation Model: Bioassay Data Interpretation and Dose Assessment after Plutonium Intake via Wound and Treatment with DTPA

The administration of chelation therapy to treat significant intakes of actinides, such as plutonium, affects the actinide’s normal biokinetics. In particular, it enhances the actinide’s rate of excretion, such that the standard biokinetic models cannot be applied directly to the chelation-affected bioassay data in order to estimate the intake and assess the radiation dose. Here we propose a new chelation model that can be applied to the chelation-affected bioassay data after plutonium intake via wound and treatment with DTPA. In the proposed model, chelation is assumed to occur in the blood, liver, and parts of the skeleton. Ten datasets, consisting of measurements of 14 C-DTPA, 238 Pu, and 239 Pu involving humans given radiolabeled DTPA and humans occupationally exposed to plutonium via wound and treated with chelation therapy, were used for model development. The combined dataset consisted of daily and cumulative excretion (urine and feces), wound counts, measurements of excised tissue, blood, and post-mortem tissue analyses of liver and skeleton. The combined data were simultaneously fit using the chelation model linked with a plutonium systemic model, which was linked to an ad hoc wound model. The proposed chelation model was used for dose assessment of the wound cases used in this study.

60 APPLIED LIFE SCIENCES↗

Performance of the Moving Voxel Image Reconstruction (MVIR) Method in the Fixed Site Detection System (FSDS) Prototype

We have developed a dynamic image reconstruction method called MVIR (Moving Voxel Image Reconstruction) for lane detection in multilane portal monitor systems. MVIR was evaluated for use in the Fixed Site Detection System, a prototype three-lane portal monitor system for EZ-pass toll plazas. As a baseline, we compared MVIR with a static image reconstruction method in analyzing the same real and simulated data sets. Performance was judged by the distributions of image intensities for source and no-source vehicles over many trials as a function of source strength. We found that MVIR produced significantly better results in all cases. The performance difference was greatest at low count rates, where source/no-source distributions were well separated with the MVIR method, allowing reliable source vehicle identification with a low probability of false positive identifications. Static reconstruction of the same data produced overlapping distributions that made source vehicle identification unreliable. The performance of the static method was acceptable at high count rates. Both algorithms reliably identified two strong sources passing through at nearly the same time.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

High-count-rate effects in event processing for the XRISM/Resolve X-ray microcalorimeter. II. Energy scale and resolution in orbit

The Resolve instrument on the X-ray Imaging and Spectroscopy Mission (XRISM) uses a 36 pixel microcalorimeter designed to deliver high-resolution, non-dispersive X-ray spectroscopy. Although it is optimized for extended sources with low count rates, Resolve observations of bright point sources are still able to provide unique insights into the physics of these objects, as long as high-count-rate effects are addressed in the analysis. These effects include the loss of exposure time for each pixel, changes in the energy scale, and changes in the energy resolution. To investigate these effects under realistic observational conditions, we observed the bright X-ray source, the Crab Nebula, with XRISM at several offset positions with respect to the Resolve field of view and with continuous illumination from 55 Fe sources on the filter wheel. For the spectral analysis, we excluded data where exposure-time loss was too significant to ensure reliable spectral statistics. The energy scale at 6 keV shows a slight negative shift in the high-count-rate regime. The energy resolution at 6 keV worsens as the count rate in electrically neighboring pixels increases, but can be restored by applying a nearest-neighbor coincidence cut (“cross-talk cut”). We examined how these effects influence the observation of bright point sources, using GX 13+1 as a test case, and identified an eV-scale energy offset at 6 keV between the inner (brighter) and outer (fainter) pixels. Users who seek to analyze velocity structures on the order of tens of km s–1 should account for such high-count-rate effects. These findings will aid in the interpretation of Resolve data from bright sources and provide valuable considerations for designing and planning for future microcalorimeter missions.

X-rays: general↗

X-ray multi-probe data acquisition: A novel technique for laser pump x-ray transient absorption spectroscopy

We report the development and implementation of a novel data acquisition (DAQ) technique for synchrotron-based laser pump X-ray Transient Absorption (XTA) spectroscopy, called X-ray Multi-Probe DAQ (XMP DAQ). This technique utilizes high performance analog to digital converters and home-built software to efficiently measure and process the XTA signal from all x-ray pulses between laser excitations. XMP DAQ generates a set of time resolved x-ray absorption spectra at thousands of different pump–probe time delays simultaneously. Two distinct XMP DAQ schemes are deployed to accommodate different synchrotron storage ring filling patterns. Current Integration (CI) DAQ is a quasi-analog technique that implements a fitting procedure to extract the time resolved absorption intensity from the averaged fluorescence detector response. The fitting procedure eliminates issues associated with small drifts in the voltage baseline and greatly enhances the accuracy of the technique. Photon Counting (PC) DAQ is a binary technique that uses a time resolved histogram to calculate the XTA spectrum. While PC DAQ is suited to measure XTA data with closely spaced x-ray pulses (~10 ns) and a low count rate (<1 detected photon/pulse), CI DAQ works best for widely spaced pulses (tens of ns or greater) with a high count rate (>1 detected photon/pulse). XMP DAQ produces a two-dimensional XTA dataset, enabling efficient quantitative analysis of photophysical and photochemical processes from the sub-nanosecond timescale to 100 μs and longer.

47 OTHER INSTRUMENTATION↗

Nonperturbative NN scattering in {sup 3}S{sub 1}–{sup 3}D{sub 1} channels of EFT(⁄π)

The closed-form T matrices in the {sup 3}S{sub 1}–{sup 3}D{sub 1} channels of EFT(⁄π) for NN scattering with the potentials truncated at order O(Q{sup 4}) are presented with the nonperturbative divergences parametrized in a general manner. The stringent constraints imposed by the closed form of the T matrices are exploited in the underlying theory perspective and turned into virtues in the implementation of subtractions and the manifestation of power counting rules in nonperturbative regimes, leading us to the concept of EFT scenario. A number of scenarios of the EFT description of NN scattering are compared with PSA data in terms of effective range expansion and {sup 3}S{sub 1} phase shifts, showing that it is favorable to proceed in a scenario with conventional EFT couplings and sophisticated renormalization in order to have large NN scattering lengths. The informative utilities of fine tuning are demonstrated in several examples and naturally interpreted in the underlying theory perspective. In addition, some of the approaches adopted in the recent literature are also addressed in the light of EFT scenario. -- Highlights: •Closed-form unitary T matrices for NN scattering are obtained in EFT(⁄π). •Nonperturbative properties inherent in such closed-form T matrices are explored. •Nonperturbative renormalization is implemented through exploiting these properties. •Unconventional power counting of couplings is shown to be less favored by PSA data. •The ideas about nonperturbative renormalization here might have wider applications.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Solution of Heliospheric Propagation: Unveiling the Local Interstellar Spectra of Cosmic-ray Species

Local interstellar spectra (LIS) for protons, helium, and antiprotons are built using the most recent experimental results combined with state-of-the-art models for propagation in the Galaxy and heliosphere. Two propagation packages, GALPROP and HelMod, are combined to provide a single framework that is run to reproduce direct measurements of cosmic-ray (CR) species at different modulation levels and at both polarities of the solar magnetic field. To do so in a self-consistent way, an iterative procedure was developed, where the GALPROP LIS output is fed into HelMod, providing modulated spectra for specific time periods of selected experiments to compare with the data; the HelMod parameter optimization is performed at this stage and looped back to adjust the LIS using the new GALPROP run. The parameters were tuned with the maximum likelihood procedure using an extensive data set of proton spectra from 1997 to 2015. The proposed LIS accommodate both the low-energy interstellar CR spectra measured by Voyager 1 and the high-energy observations by BESS, Pamela, AMS-01, and AMS-02 made from the balloons and near-Earth payloads; it also accounts for Ulysses counting rate features measured out of the ecliptic plane. The found solution is in a good agreement with proton, helium, and antiproton data by AMS-02, BESS, and PAMELA in the whole energy range.

79 ASTRONOMY AND ASTROPHYSICS↗

Systematic Uncertainties in High-Rate Germanium Data

For many nuclear material safeguards inspections, spectroscopic gamma detectors are required which can achieve high event rates (in excess of 10^6 s^-1) while maintaining very good energy resolution for discrimination of neighboring gamma signatures in complex backgrounds. Such spectra can be useful for non-destructive assay (NDA) of spent nuclear fuel with long cooling times, which contains many potentially useful low-rate gamma lines, e.g., Cs-134, in the presence of a few dominating gamma lines, such as Cs-137. Detectors in use typically sacrifice energy resolution for count rate, e.g., LaBr3, or visa versa, e.g., CdZnTe. In contrast, we anticipate that beginning with a detector with high energy resolution, e.g., high-purity germanium (HPGe), and adapting the data acquisition for high throughput will be able to achieve the goals of the ideal detector. In this work, we present quantification of Cs-134 and Cs-137 activities, useful for fuel burn-up quantification, in fuel that has been cooling for 22.3 years. A segmented, planar HPGe detector is used for this inspection, which has been adapted for a high-rate throughput in excess of 500k counts/s. Using a very-high-statistic spectrum of 2.4*10^11 counts, isotope activities can be determined with very low statistical uncertainty. However, it is determined that systematic uncertainties dominate in such a data set, e.g., the uncertainty in the pulse line shape. This spectrum offers a unique opportunity to quantify this uncertainty and subsequently determine required counting times for given precision on values of interest.

burn-up↗

LC-MEMENTO: A Memory Model for Accelerated Architectures

With the advent of heterogeneous architectures, in particular, with the ubiquity of multi-GPU systems, it is becoming increasingly important to manage device memory efficiently in order to reap the benefits of the additional core count. To date, such responsibility mainly falls on the programmer where device-to-host data communication (and vice versa), if not done properly, may incur costly memory transfer operations and synchronization. The problem may be compounded by additional requirement to maintain system-wide memory consistency that may involve expensive synchronization overhead. In this paper, we present Location Consistency Memory Model for Enhanced Transfer Operations (LC-MEMENTO). This framework considers incorporating runtime techniques for multi-GPU memory management to support relaxed synchronization semantics and memory transfer operations automatically. Specifically, we implement a relaxed form of a memory consistency model based on the Location Consistency (LC) in an Asynchronous Many-Task Runtime (ARTS) and demonstrate that, this memory model enables additional optimization opportunities for the three representative applications encompassing different computational patterns (scientific computation, graphs, data streaming, etc.).

Memory Models, Accelerators, Adaptive Optimization↗

Testing Fluorescence Lifetime Standards using Two-Photon Excitation and Time-Domain Instrumentation: Fluorescein, Quinine Sulfate and Green Fluorescent Protein

It is essential for everyone working with experimental science to be certain that their instruments produce reliable results, and for fluorescence lifetime experiments, information about fluorescence lifetime standards is crucial. A large part of the literature on lifetime standards dates back to the 1970s and 1980s, and the use of newer and faster measuring devices may deem these results unreliable. We have tested the three commonly used fluorophores fluorescein, quinine sulfate and green fluorescent protein for their suitability to serve as lifetime standards, especially to be used with two-photon excitation measurements in the time-domain. We measured absorption and emission spectra for the fluorophores to determine optimal wavelengths to use for excitation and detector settings. Fluorescence lifetimes were measured for different concentrations, ranging from 10{sup − 3} − 10{sup − 5} M, as well as for various solvents. Fluorescein was soluble in both ethanol, methanol and sulfuric acid, while quinine sulfate was only soluble in sulfuric acid. Green fluorescent protein was prepared in a commercial Tris-HCl, EDTA solution, and all three fluorophores produced stable lifetime results with low uncertainties. No siginificant variation with concentration was measured for any of the fluorophores, and all showed single-exponential decays. All lifetime measurements were carried out using two-photon excitation and lifetime data was obtained in the time-domain using time-correlated single-photon counting.

74 ATOMIC AND MOLECULAR PHYSICS↗

Semiquantitative Analysis Using Thallium-201 SPECT for Differential Diagnosis Between Tumor Recurrence and Radiation Necrosis After Gamma Knife Surgery for Malignant Brain Tumors

Purpose: Semiquantitative analysis of thallium-201 chloride single photon emission computed tomography ({sup 201}Tl SPECT) was evaluated for the discrimination between recurrent brain tumor and delayed radiation necrosis after gamma knife surgery (GKS) for metastatic brain tumors and high-grade gliomas. Methods and Materials: The medical records were reviewed of 75 patients, including 48 patients with metastatic brain tumor and 27 patients with high-grade glioma who underwent GKS in our institution, and had suspected tumor recurrence or radiation necrosis on follow-up neuroimaging and deteriorating clinical status after GKS. Analysis of {sup 201}Tl SPECT data used the early ratio (ER) and the delayed ratio (DR) calculated as tumor/normal average counts on the early and delayed images, and the retention index (RI) as the ratio of DR to ER. Results: A total of 107 tumors were analyzed with {sup 201}Tl SPECT. Nineteen lesions were removed surgically and histological diagnoses established, and the other lesions were evaluated with follow-up clinical and neuroimaging examinations after GKS. The final diagnosis was considered to be recurrent tumor in 65 lesions and radiation necrosis in 42 lesions. Semiquantitative analysis demonstrated significant differences in DR (P=.002) and RI (P<.0001), but not in ER (P=.372), between the tumor recurrence and radiation necrosis groups, and no significant differences between metastatic brain tumors and high-grade gliomas in all indices (P=.926 for ER, P=.263 for DR, and P=.826 for RI). Receiver operating characteristics analysis indicated that RI was the most informative index with the optimum threshold of 0.775, which provided 82.8% sensitivity, 83.7% specificity, and 82.8% accuracy. Conclusions: Semiquantitative analysis of {sup 201}Tl SPECT provides useful information for the differentiation between tumor recurrence and radiation necrosis in metastatic brain tumors and high-grade gliomas after GKS, and the RI may be the most valuable index for this purpose.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

β-decay and β-delayed Neutron Emission Measurements at GSI-FRS Beyond N=126, for r-process Nucleosynthesis

New measurements of very exotic nuclei in the neutron-rich region beyond N=126 have been performed at the GSI facility with the fragment separator (FRS). The aim of the experiment is to determine half-lives and β-delayed neutron emission branching ratios of isotopes of Hg, Tl and Pb in this region. This contribution summarizes final counting statistics for identification and for implantation, as well as the present status of the data analysis of the half-lives. In summary, isotopes of Pt, Au, Hg, Tl, Pb, Bi, Po, At, Rn and Fr were clearly identified and several of them ({sup 208-211}Hg, {sup 211-215}Tl, {sup 214-218}Pb) were implanted with enough statistics to determine their half-lives. About half of them are expected to be neutron emitters, in such cases it will become possible to obtain the neutron emission probabilities, Pn.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Pro-angiogenic properties of orosomucoid (ORM)

The acute phase protein orosomucoid (ORM), also known as alpha1-acid glycoprotein (AGP), is found to be increased in infection, inflammation and cancer. Recently, we demonstrated that ORM is produced by endothelial cells and detectable in urine samples of patients with bladder cancer. However, it was not clarified yet whether ORM plays a role in new vessel formation. To this aim we performed overexpression and gene silencing for ORM in human microvascular endothelial cells (HDMECs). ORM purified from human plasma was used individually or in combination with VEGF-A in endothelial tube formation, migration and proliferation assay. The in vivo effect of ORM in angiogenesis was studied using the chicken chorionallantois membrane (CAM) with subsequent counting of blood vessels on histological sections from the stimulated areas of CAM tissue. Our data show that ORM alone enhances migration but not proliferation of HDMECs. ORM alone does not induce endothelial tubes in vitro but simultaneous application of ORM with VEGF-A increases the number and the network of VEGF-A-induced endothelial tubes. Remarkably, ORM alone induces new vessel formation in vivo using CAM assay and supports the VEGF-A-induced new vessel formation in this assay. Taken together, our results let assume that ORM has pro-angiogenic properties and supports the angiogenic effect of VEGF-A. Thus, ORM seems to be involved in the regulation of angiogenesis.

60 APPLIED LIFE SCIENCES↗

TGCat : THE CHANDRA TRANSMISSION GRATING DATA CATALOG AND ARCHIVE

The Chandra Transmission Grating Data Archive and Catalog (TGCat) provides easy access to analysis-ready products, specifically, high-resolution X-ray count spectra and their corresponding calibrations. The web interface makes it easy to find observations of a particular object, type of object, or type of observation; to quickly assess the quality and potential usefulness of the spectra from pre-computed summary plots; or to customize a view with an interactive plotter, optionally combining spectra over multiple orders or observations. Data and responses can be downloaded as a package or as individual files, and the query results themselves can be retrieved as ASCII or Virtual Observatory tables. Portable reprocessing scripts used to create the archive and which use the Chandra X-ray Center's (CXC's) software and other publicly available software are also available, facilitating standard or customized reprocessing from Level 1 CXC archival data to spectra and responses with minimal user interaction.

79 ASTRONOMY AND ASTROPHYSICS↗

1990 The Twin Cities Metropolitan Area Travel Behavior Inventory

The Twin Cities Metropolitan Area 1990 Travel Behavior Inventory, or home interview survey, was conducted by Twin Cities Metropolitan Council—Saint Paul to document how Twin Cities residents use the streets, highways, and transit services in the region. The survey collected demographic, socioeconomic, and travel data for 9,476 households. Respondents were asked to record their travel and activities for a 24-hour period, in which 98,535 trips were documented. In addition to the home interview survey, the study included an establishment survey, a transit survey, external station traffic counts, and an external station origin/destination survey.

1Hz data↗

A Mixture Evolution Scenario of the AGN Radio Luminosity Function. II. Do Low- and High-power Radio-loud AGNs Evolve Differently?

Following previous work, we further confirm that the cosmic evolution of steep-spectrum radio-loud AGNs (active galactic nuclei) can be reproduced by a simple combination of density evolution (DE) and luminosity evolution (LE). This mixture evolution scenario can naturally explain the luminosity-dependent evolution of radio-loud AGNs. Our models successfully fitted a large amount of data on radio luminosity functions of steep-spectrum sources and multi-frequency source counts. The modeling indicates that the DE slowly increases as (1+z){sup 0.3∼1.3} out to z∼0.8, and then rapidly decreases as (1+z){sup −6.8∼−5.7}, while the LE rapidly increases as (1+z){sup 4.8} out to a higher redshift (at least z>3.5). We find a high-redshift decline (i.e., redshift cutoff) in the number density of steep-spectrum radio sources, but we cannot conclude whether such a decline is sharp or shallow. We believe that whether a redshift cutoff occurs or not depends mainly on DE, while its steepness is decided by LE, which, however, cannot be well constrained due to the lack of high-redshift samples. Most intriguingly, according to our mixture evolution scenario, there appears to be no need for different evolution for the low- and high-power radio-loud AGNs. Both types of sources experience the same combined evolution of DE and LE.

79 ASTRONOMY AND ASTROPHYSICS↗

Multi-resonant switched capacitor power converter architecture

A switched-capacitor (SC) network in an SC converter is controlled to operate at varying resonant modes to achieve high conversion ratio efficiency, at a low circuit component count. These power converters are suited to numerous application areas including improving energy efficiency of data centers. A family of resonant switched capacitor (SC) converters with multiple operating phases are presented “Multi-Resonant SC Converters”. Described in detail are an 8-to-1 Multi-Resonant-Doubler (MRD) converter and a 6-to-1 Cascaded Series-Parallel (CaSP). The topology of these converters make them amenable to combining like units in parallel toward reaching higher power levels.

Ye, Zichao↗

Guide for SDEC Set up

The instrument has four collection vials that must be filled with ethylene glycol before operation. Each of the four vials should be labeled 1 through 4 and the empty weights recorded. Fill each vial with 80 mL of ethylene glycol and record the weight again. In order for the instrument to operate properly, the collection vials should always have less than 160 mL of total liquid in them. After completing a sample run, remove the collection vials, use a transfer pipette to remove any liquid that might still be on the air paddler, wipe off any condensation from the exterior of the collection vial and record weight. From the instrument, record the ending volume and the time of operation. The solution mixed in the scintillation vial will be 2 ml of a 95% to 50% ethylene glycol to water mixture. To determine the efficiency of counting at all of these concentrations, a series of vials should be set up that consist of 18 ml of Ultima Gold LLT cocktail mixed with standard, regular deionized water and ethylene glycol. The efficiency curve should be counted in the 'Low Level' count mode with the Luminescence Correction ON and the Color Quench Correction ON. Once the tSIE values are determined, chart the cpm against the tSIE numbers and find the best fit for the data. The resulting equation is to be used to converting tSIE values from the collection vials to efficiency. To determine the background cpm value of the ethylene glycol, count a 2 ml sample of ethylene glycol with 18 ml of Ultima Gold for 100 minutes. To determine the total activity of the sample, take two 2 ml aliquots of sample from the first vial and place in separate scintillation vials. Record the weight of each aliquot. Determine the percentage of total sample each aliquot represents by dividing the aliquot weight by the total solution weight from the vial. Also, determine the percentage of ethylene glycol in the sample by dividing the initial solution weight by the final solution weight and multiplying by 100. Add 18 ml of Ultima Gold to each vial and proceed to count for 100 minutes in a 'Low Level' count mode. Before performing a calculation on the dpm value of each aliquot, a subtraction should be made for the background count rate of the ethylene glycol. Based on the background cpm, multiply the background cpm value by the percentage of ethylene glycol in the collection vial. Once the background value is subtracted, calculate the dpm value of the sample based on the tSIE conversion to efficiency. This will produce a dpm value. To convert this to a total activity of the sample, divide the aliquot dpm value by the decimal percentage of total sample the aliquot represents. This gives the total activity of the sample solution. Take the average of both aliquots as a final result. To convert the total activity from the solution in vial one to activity in air, an empirical formula is used to convert activity/gram from vial one to total activity introduced into the system. After calculation the final result for the vial, divide the total by the mass of the sample in vial one. This gives dpm/g (labeled C{sub m}). To convert this to total dpm measured, C = (128.59 * Cm + 10.837)/V Where: C = Tritium concentration in air (dpm/m{sup 3}) C{sub m} = measured tritium concentration from vial 1 (dpm/g) V = Volume of air sampled through instrument (m{sup 3}). C is the final value of tritium concentration in air.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗