A remarkable CHF of 345W/cm 2 is achieved in a wicked-microchannel using HFE-7100

Boiling heat transfer of dielectric fluids is a promising cooling technique for thermal management of microelectronic systems. However, the critical heat flux achievable is generally low, because of the poor thermophysical properties of these fluids. Here, to address this dilemma, we propose a new cooling concept to substantially enhance global liquid supply during phase-change process using enhanced capillary-driven force. Additionally, dedicated vapor pathways are designed among a bank of micro-pillars to facilitate vapor removal. In this work, new wicks comprised of silicon micro-pinfin arrays are explored to significantly enhance the flow boiling heat transfer performance. To examine the functionalities of this wick, experiments on HFE-7100 were carried out with mass velocities varying from 247 to 3,465 kg/m 2 s. To explore the enhancement mechanisms and to analyze the capillary-assisted flow boiling process, visualization studies were conducted. The results indicate that sustainable evaporation induced by wick microstructures and efficient liquid supply are the enhancement mechanisms compared to parallel microchannels with solid walls. It is found that the overall heat transfer coefficient is substantially increased up to 75%. Remarkably, a high critical heat flux (CHF) of approximately 345 W/cm 2 is recorded at G = 3,465 kg/m 2 s at coolant inlet temperature of ~20 °C. Equally importantly, this noticeable enhancement of CHF value is associated with drastically decreased pressure drops compared to microchannels decorated with μ-pinfin fences.

36 MATERIALS SCIENCE↗

Tutorial - Electric Motor and Integrated Traction Drive Thermal Management

The share of vehicles with fully electric propulsion systems is constantly increasing, and so is their traction drive power. The continuous push to increase power of electric vehicle (EV) traction drives necessitates their efficient cooling to prevent damage to temperature sensitive components of the drive system and achieving higher power outputs in a smaller footprint. With increasing power and power density of electric traction drives, their thermal management is becoming increasingly challenging. This tutorial will provide an overview of thermal management approaches for electric motors and power electronics in EV applications. It will review examples of current industry solutions for power-dense electric motor cooling, power electronics (inverter) cooling, their integration concepts and thermal management system solutions. We'll look at the advantages and challenges of power electronics integration into a single traction drive unit and respective thermal management system concepts. We'll talk about barriers to implementation of a unified thermal management system. The tutorial will also review key aspects of thermal management system design: modeling and simulation using FEA and CFD tools, experimental characterization, and general workflow for thermal management system evaluation.

ADVANCED PROPULSION SYSTEMS,DIRECT ENERGY CONVERSI↗

Multi-Split Variable Refrigerant Flow (VRF) System Building Energy Simulations Using Performance Maps

Multi-split variable refrigerant flow (VRF) systems are highly energy-efficient HVAC (heating, ventilation and air conditioning) technologies that connect a single outdoor unit to multiple independent indoor terminal units using a common refrigerant circuit and a variable-speed compressor. Building energy simulations that incorporate VRF systems help model their unique operational characteristics and predict energy consumption in specific building designs. Traditionally, EnergyPlus models these systems by employing multiple sets of performance curves to characterize both individual terminal units and the outdoor unit. However, producing these curves is labor intensive and error prone, and they often do not capture all the key input and output variables. This paper introduces a novel approach that uses multi-dimensional performance maps to model VRF systems in building environments for space cooling. In this approach, performance maps are developed at the component level—separately for the outdoor unit and for each indoor terminal. The new modeling method is validated within EnergyPlus via a Python plug-in that contains a simple solver loop to coordinate the component-level, indoor, and outdoor unit maps. Furthermore, because performance maps can span more variables than traditional performance curves, they offer the opportunity to implement advanced controls, such as enhanced dehumidification and compressor modulation. A VRF air conditioner’s hardware system was modeled using the DOE/ORNL Heat Pump Design Model, which was automated to produce extensive performance maps for both the indoor and outdoor units.

Shen, Bo [ORNL] (ORCID:0000000336600393)↗

ITER ECH Transmission Line System Design and Status

The electron cyclotron (EC) heating & current drive (H&CD) system on ITER provides plasma heating by generating, transmitting, and launching high-intensity, high-frequency (170 GHz) electromagnetic wave energy steerable across the plasma cross-section. The transmission line (TL) subsystem connects the Matching Optics Unit (MOU) on each of the 24 gyrotrons to the 32 feed points in the four upper launchers and the 24 feed points in the equatorial launcher. Each TL must be able to operate at up to 1.2 MW of input power for up to 1 hour pulse lengths. The TL system contains 50 mm water-cooled corrugated waveguide, 90o miter bends, 140o miter bends, polarizer miter bend pairs, switches, expansion units, pumpouts, DC breaks, MOU-TL adapters, Radio Frequency (RF) loads, and isolation shutter valves. A detailed finite element analysis has been used to verify the thermo-mechanical performance of each component. The microwave performance has been analyzed using a 2-D electromagnetic code combined with a Monte Carlo code. This approach allows the impact of manufacturing and installation tolerances to be assessed and optimized to provide a high probability of achieving the system performance requirements. Prototypes of the waveguide and TL components have been fabricated and tested at high-power. Production contracts are now being issued for fabrication and delivery of the waveguide and components to ITER.

Hanson, Gregory↗

Design, modeling and simulation of nuclear-powered integrated energy systems with cascaded heating applications

Nuclear-renewable integrated energy systems (IES) consist of a variety of energy generation and conversion technologies and can be used to meet heterogeneous end uses (e.g., electricity, heat, and cooling demands). In addition to supply-demand balance, end-use heat demands usually require heat supply of certain temperature ranges. The effective and efficient utilization of heat produced within an IES is, therefore, a critical challenge. Here, this paper examines design options of an IES that includes heating processes of multiple temperature grades. We investigate a cascaded design configuration, where the remaining residual heat after high-grade heating processes [e.g., hydrogen production through high-temperature steam electrolysis (HTSE)] is recovered to meet the low-grade heating needs [e.g., district heating (DH)]. Additionally, a thermal energy storage system is integrated into the DH system to address the imbalance between heat supply and demand. This paper primarily focuses on the design and modeling of the proposed system and evaluates its operation with a 24-h transient process simulation using a DH demand profile with hourly resolution. The results indicate that the residual heat from the HTSE exhaust is insufficient for the DH demand, and additional topping heat directly from the reactor process steam is needed. Furthermore, the inclusion of thermal energy storage within the DH system provides the necessary balance between thermal generation and demand, thereby ensuring a consistent rated temperature of the DH supply water. This approach helps minimize the control actions needed on the reactor side.

08 HYDROGEN↗

Technoeconomic Analysis of Changing PV System Layout and Convection Heat Transfer

This work includes analysis of potential economic improvements for PV systems for changing system parameters such as ground coverage ratio that alter the convective cooling consideration on PV modules through a newly proposed convective curve fit. Accounting for the spatial layout of the system in the convection heat transfer calculations allows for more accuracy in convective cooling load and subsequent module temperature calculations. The changing heat transfer considerations can be shown to improve system LCOE along with improved incident irradiance from increased row spacing despite the additional system costs incurred with increased module spacing. State-level analyses show that the impact of decreasing system GCR is greatest for climates with cold average annual ambient temperatures and moderate to high average annual wind speeds. Further waterfall analysis of changing system parameters reveals that the changing heat transfer dynamics have a non-negligible impact on system LCOE when compared to the changes in incident irradiance that serve as the primary driver of annual energy performance changes.

ENERGY PLANNING, POLICY, AND ECONOMY,SOLAR ENERGY↗

Simulation of a PCM Integrated Heat Pump Using Time-of-Use Utility Structure based Control Strategy for Demand Response

To mitigate the variation in demand on the electric grid, thermal energy storage (TES) is an alternative to electric batteries and constructing new peaking power plants. The aggressive carbon reduction goals of the United States are accelerating the electrification of building equipment. If space heating and cooling in the US were electrified using conventional heat pump technologies, the winter electric grid peak would approximately double. Integrating TES with heat pump (HP) enables electrification of space cooling and heating devices without overtaxing the grid.This paper evaluates the benefits of a novel phase change material (PCM) integrated heat pump configuration via simulation. A one-dimensional PCM heat exchanger model which discretizes the PCM tank and refrigerant tubes into small control volumes is developed. Each control volume can have different PCM temperatures, PCM properties, and heat transfer coefficients. The PCM tank is charged by a wrapped tank condenser and discharged by an internal refrigerant coil. The PCM heat exchanger model is integrated into DOE/ORNL Heat Pump Design Model for heat pump system simulation.To demonstrate the performance of the PCM integrated heat pump, a case study in Chicago was performed. A Time-of-Use utility structure-based control strategy is implemented to schedule the PCM tank charging and discharging mode switching. Compared with a conventional electric heat pump, the PCM integrated heat pump shows superior performance on load shifting and utility cost reduction. As a result, the proposed system demonstrates 24.6% utility saving for cooling application and 25.8% utility saving for heating application.

Li, Zhenning↗

Advanced Airfoil Cooling Schemes to Increase Efficiency in Gas Turbines for Combined Heat and Power Applications

This report describes a three-year interdisciplinary effort funded by the U.S. Department of Energy’s (DOE) Energy Efficiency and Renewable Energy/Advanced Manufacturing Office (EERE/AMO) to promote market penetration of combined heat and power (CHP) technologies. Prior studies have shown the technical potential for CHP in the United States is much larger than the current deployment of CHP systems. A large portion of the technical potential CHP market aligns with small (<20 MWe) gas turbines. CHP systems are an attractive alternative to reduce greenhouse gas (GHG) emissions. For example, CHP systems can reduce GHG emissions by 30–40% relative to a conventional boiler and power configuration. These GHG emission reductions are “avoided emissions” which means no CO 2 separation or sequestration is required. This report describes an effort to use additive manufacturing (AM) technologies and advanced airfoil cooling designs to increase the turbine inlet temperature by 100 °C for small gas turbines typically used in CHP systems. At the beginning of this effort, baseline performance data for small gas turbines was not available, and the potential benefits of cooling system improvements were not quantified in the available literature.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

DEVELOPMENT OF A LUMPED-PARAMETER THERMAL MODEL FOR ELECTRO-HYDRAULIC ACTUATORS

This paper describes a thermal-hydraulic modeling method of a closed-circuit electro-hydraulic actuator (EHA). Despite the high energy efficiency of EHAs, it is always important to assess their cooling requirements, to guarantee that the operating temperature remains within an acceptable range. The method proposed in this paper is based on a lumped parameter approach and simplifies some of the complex heat transfer processes by introducing empirical correction factors. The model is validated by means of temperature measurements on an EHA architecture developed by the author. The good match between the simulation results and experiments confirms the capability of the proposed methodology to predict the temperature performance of the reference EHA under different drive cycles. The paper presents a detailed analysis of the power losses and passive heat dissipation for the reference system. Based on this analysis, the cooling requirements of the EHA are studied.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Development and Validation of a Probabilistic Risk Assessment Model for a Generic Modular High Temperature Gas-Cooled Reactor

This study looks to develop and validate a probabilistic risk assessment (PRA) model for the modular high temperature gas-cooled reactor (MHTGR) using INL’s Systems Analysis Programs for Hands-on Integrated Reliability Evaluations (SAPHIRE) software. Validation against a General Atomics design involves matching event and fault trees to historical frequencies, with a goal of under 15% difference. The research aims to deliver a reliable PRA model to assess the safety of MHTGRs for use within high-temperature industrial applications.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

National Park Service Bus Electrification Study: 2020 Report

This report summarizes important considerations for implementing BEBs in the three national park fleets, detailing information about current buses at each fleet, electric bus demonstration vehicles, as well as performance evaluations of BEBs in Zion, Bryce, and Yosemite. Results include in-use data collection results reporting metrics such as average bus speed, energy usage per trip, and daily distance traveled, as well as effects of high heating, ventilation, and air conditioning (HVAC) system use to both heat and cool the buses, emissions estimations before and after use of electric buses, operating costs, electric vehicle infrastructure, maintenance, and bus driver user experience survey information. Analysis results from this project will help the NPS understand how BEBs and future expansion of BEBs could assist in meeting their bottom line and operational goals and assist NPS in choosing appropriate locations for future BEB deployments.

33 ADVANCED PROPULSION SYSTEMS↗

A Life Cycle Analysis Framework for Point Source Capture Systems

NETL studies the costs and benefits of PSC for electricity, industry, and mobile applications. Mobile point source capture (MPSC) and storage applied to freight modes captures emissions directly from exhaust. This poster presents a framework for conducting LCA of PSC systems applied to heavy-duty trucks, freight trains, and marine vessels. The framework defines a wheels-to-storage (gate-to-grave) boundary, including energy demands (electricity, heat, and cooling requirements), solvent use and cycling, onboard system components, carbon storage in a saline aquifer, and upstream manufacturing impacts for equipment, with a suggested functional unit of 1 tonne-km. Potential data sources for analysis include material, energy, and operational data from Oak Ridge National Laboratory, GREET (Greenhouse gases, Regulated Emissions, and Energy use in Technologies) model, and scientific literature. The suggested analytical approach includes comparison to publicly available business-as-usual systems without capture across all modes of transportation, sensitivity to composition of the capture solvent, and sensitivity to capture rate variation, all of which would support a wholistic PSC business case analysis. For future consideration, analysis can be augmented with consideration of different sources of electricity (e.g., nuclear), fuel substitution, deploying supportive infrastructure such as pipeline offloading points, and downstream applications like enhanced oil recovery (EOR).

life cycle analysis (LCA)↗

Progress in ITER ECE diagnostic design and integration

The ITER electron cyclotron emission (ECE) diagnostic system has primary roles in providing measurements of the core electron temperature profile and the electron temperature fluctuation associated with the neoclassical tearing modes. The ITER ECE system includes a radial and oblique line-of-sight. Four 43-meter long low-loss transmission lines (TLs) are designed to transmit millimeter wave power in the frequency range of 70–1000 GHz in both X- and O-mode polarization from the port plug to the ECE instrumentation room in the diagnostic building. The measurement instrumentation includes two Fourier transform spectrometer (FTS) systems and two radiometer systems. The Indian Domestic Agency (IN-DA) and United States Domestic Agency share the responsibility. The IN-DA scope excluding instrumentation and control has passed its preliminary design review and is progressing towards the final design review (FDR). In parallel, the diagnostic integration in different areas is ongoing. Furthermore, several captive components for the TLs have passed FDR and will be manufactured for installation in the tokamak building soon. A peer review meeting has been held on the prototype hot calibration source, and its integration and new thermal analysis in the diagnostic shield module are continuing. A prototype TL is being tested. A prototype polarizing Martin-Puplett type FTS, operating in the frequency range 70–1000 GHz, features an in-vacuo fast scanning mechanism and a cryo-cooled dual-channel THz detector system. Its performance has been assessed in detail against ITER requirements.

47 OTHER INSTRUMENTATION↗

Experimental Validation of Thermal Hydraulic Behavior in Sodium Fast Reactors (SFR) with the Thermal Hydraulic Experimental Test Article (THETA)

Thermal stratification and transition to natural circulation pose two of the largest sources of uncertainty in systems-level modeling of liquid metal-cooled fast reactors. As these phenomena typically develop during transient event sequences, licensing-basis events analyzed using systemslevel models may have considerable uncertainties associated with thermal-hydraulic parameters of the system to account for these phenomena. As a result, the validation basis for these phenomena for systems-level codes is insufficient to fully support the wide range of liquid metal fast reactors being developed in the US. Currently, the most viable path for licensing a design is to take significant conservatisms and maintain sufficiently large safety margins to account for this uncertainty.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

A Hybrid Heavy Duty Diesel Power System for Off-Road Applications—Concept Validation

A multiyear power system R&D program was completed with the objective of developing an off-road hybrid heavy duty diesel engine with front end accessory drive-integrated energy storage. This system was validated to deliver 10.5–25.6% reduction in fuel consumption over current Tier 4 Final-based 18L diesel engines, over various off-road machine application cycles. The power system consisted of a downsized heavy-duty diesel 13L engine containing advanced combustion technologies, capable of elevated peak cylinder pressures and thermal efficiencies, thermal barrier coatings, exhaust waste heat recovery via SuperTurbo™ turbocompounding, and hybrid energy assisting and recovery through both mechanical and electrical systems. Following the concept definition, design, and analysis phases of the program, the final phase focused on building and validating the performance and efficiency in laboratory tests. While aspects of the system such as start/stop and reduced off-road cooling package energy losses were only analytically evaluated, the main 13L concept engine with full hybrid system was successfully built and tested in steady-state and in transient certification and real-world application cycles. Extensive simulations in Caterpillar's DYNASTY™ software environment utilized the validation test data to assess performance more fully and confidently over varied cycles and strategies. An average fuel consumption reduction of 17.9% was realized, and the majority (~13%) of the benefit stemmed from the core concept 13L engine. In conclusion, a total cost of ownership analysis provides context to commercial viability and where adoption focus should be placed.

33 ADVANCED PROPULSION SYSTEMS↗

Active and passive cooling approaches for a Southern California residential community

This study assesses cooling strategies in a low-income community in Southern California that lacks air conditioning and struggles with heat and air pollution. We used an urban building energy model and an electric distribution system model to evaluate active and passive cooling measures. The most effective space cooling measures were high-performance air-source heat pumps, cool coatings, window films, and harnessing the space cooling effect from heat pump water heaters. The results show that combining heat pump water heaters with window films and cool coatings reduces heat index hazard hours within buildings by 95 % to 99 % but increases total energy costs (equipment costs plus changes in utility bills) by 20 % to 60 % where the higher end includes building electrical upgrades. These measures also led to increased space heater use during colder months to avoid overcooling. Replacing conventional heaters with air source heat pumps eliminated unsafe indoor temperatures and reduced total energy use, but increased cost by 125 % to 150 %. In total, using heat pumps for space and water heating could reduce primary energy use by up to 57 %. The higher cost of active and passive cooling measures can be mitigated by existing and emerging incentive programs, especially those that support heat pumps. Electric distribution upgrades to support community electrification are estimated to increase utility costs by $\$$25 to $\$$40 per ratepayer per year. The results underscore the potential and challenges of adapting building infrastructure in communities at risk from climate and environmental stressors.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Review of liquid desiccant air dehumidification systems coupled with heat pump: System configurations, component design, and performance

Vapor Compression Systems (VCS) are the most common air conditioning technology. VCS cool the air to its dew point temperature (overcooling) to remove water vapor in the air through condensation and then reheats the air back to the comfort temperature for direct use. The VCS process is inefficient due to overcooling and reheating. Liquid Desiccant Dehumidification (LDD) is a potentially energy-efficient air conditioning. LDD removes water vapor in the process air using liquid desiccant’s high-water affinity. It hybrids with sensible cooling to control temperature and humidity separately. The LD in the LDD becomes weak after dehumidification. The LDD needs additional heating to regenerate the weak Liquid Desiccant (LD) to a high concentration for dehumidification. Earlier versions of the LDD systems use highly concentrated liquid desiccant (large water removal capability) to dehumidify the air by only dealing with latent load. It leads to highly elevated temperatures above 60 °C of heat sources (combustion or electric resistance-based heating) for regeneration. The energy needed for the elevated temperature heat resource significantly reduces or demolishes the benefit of LDD systems. In the recent two decades, researchers have investigated a new configured LDD system that couples an LDD with a heat pump at both dehumidification and regeneration sides for better efficiency. The heat pump provides cooling (from the evaporator) for both dehumidification and sensible cooling and simultaneous heating from the condenser for regeneration. The highly integrated system (HP-LDD) with improved efficiency enables the LDD to operate at lower concentrations and temperatures in dehumidification and regeneration. This paper depicts the working principle behind HP-LDD and its heating and cooling requirements. It reviews the comparison between the HP-LDD systems and the conventional LDD systems regarding system configurations, component design, energy efficiency, and dehumidification performance characteristics. The main findings from the review include the preferred use of packed bed over membrane-based dehumidifiers, the use of internally cooled dehumidifiers enabled by the HP cooling capacity, the high dispersion of HP operation conditions, and the dependence of dehumidification performance on various dehumidifiers. Finally, an outlook for future research on HP-LDD strategies is presented based on the reviewed works and their limitations.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

An HPC-Based Hydrothermal Finite Element Simulator for Modeling Underground Response to Community-Scale Geothermal Energy Production

Geothermal heat, as renewable energy, shows great advantage with respect to its environmental impact due to its significantly lower CO2 emissions than conventional fossil fuel. Open and closed-loop geothermal heat pumps, which utilize shallow geothermal systems, are an efficient technology for cooling and heating buildings, especially in urban areas. Integrated use of geothermal energy technologies for district heating, cooling, and thermal energy storage can be applied to optimize the subsurface for communities to provide them with multiple sustainable energy and community resilience benefits. The utilization of the subsurface resources may lead to a variation in the underground environment, which might further impact local environmental conditions. However, very few simulators can handle such a highly complex set of coupled computations on a regional or city scale. We have developed high-performance computing (HPC) based hydrothermal finite element (FE) simulator that can simulate the subsurface and its hydrothermal conditions at a scale of tens of km. The HPC simulator enables us to investigate the subsurface thermal and hydrologic response to the built underground environment (such as basements and subways) at the community scale. In this study, a coupled hydrothermal simulator is developed based on the open-source finite element library deal.II. The HPC simulator was validated by comparing the results of a benchmark case study against COMSOL Multiphysics, in which Aquifer Thermal Energy Storage (ATES) is modeled and a process of heat injection into ATES is simulated. The use of an energy pile system at the Treasure Island redevelopment site (San Francisco, CA, USA) was selected as a case study to demonstrate the HPC capability of the developed simulator. The simulator is capable of modeling multiple city-scale geothermal scenarios in a reasonable amount of time.

Sun, Xiang↗