Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “control volume methods”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 847 records · Page 47

Direct intratumoral infusion of liposome encapsulated rhenium radionuclides for cancer therapy: Effects of nonuniform intratumoral dose distribution

Purpose: Focused radiation therapy by direct intratumoral infusion of lipid nanoparticle (liposome)-carried beta-emitting radionuclides has shown promising results in animal model studies; however, little is known about the impact the intratumoral liposomal radionuclide distribution may have on tumor control. The primary objective of this work was to investigate the effects the intratumoral absorbed dose distributions from this cancer therapy modality have on tumor control and treatment planning by combining dosimetric and radiobiological modeling with in vivo imaging data. Methods: {sup 99m}Tc-encapsulated liposomes were intratumorally infused with a single injection location to human head and neck squamous cell carcinoma xenografts in nude rats. High resolution in vivo planar imaging was performed at various time points for quantifying intratumoral retention following infusion. The intratumoral liposomal radioactivity distribution was obtained from 1 mm resolution pinhole collimator SPECT imaging coregistered with CT imaging of excised tumors at 20 h postinfusion. Coregistered images were used for intratumoral dosimetric and radiobiological modeling at a voxel level following extrapolation to the therapeutic analogs, {sup 186}Re/{sup 188}Re liposomes. Effective uniform dose (EUD) and tumor control probability (TCP) were used to assess therapy effectiveness and possible methods of improving upon tumor control with this radiation therapy modality. Results: Dosimetric analysis showed that average tumor absorbed doses of 8.6 Gy/MBq (318.2 Gy/mCi) and 5.7 Gy/MBq (209.1 Gy/mCi) could be delivered with this protocol of radiation delivery for {sup 186}Re/{sup 188}Re liposomes, respectively, and 37-92 MBq (1-2.5 mCi)/g tumor administered activity; however, large intratumoral absorbed dose heterogeneity, as seen in dose-volume histograms, resulted in insignificant values of EUD and TCP for achieving tumor control. It is indicated that the use of liposomes encapsulating radionuclides with higher energy beta emissions, dose escalation through increased specific activity, and increasing the number of direct tumor infusion sites improve tumor control. For larger tumors, the use of multiple infusion locations was modeled to be much more efficient, in terms of activity usage, at improving EUD and TCP to achieve a tumoricidal effect. Conclusions: Direct intratumoral infusion of beta-emitting radionuclide encapsulated liposomes shows promise for cancer therapy by achieving large focally delivered tumor doses. However, the results of this work also indicate that average tumor dose may underestimate tumoricidal effect due to substantial heterogeneity in intratumoral liposomal radionuclide distributions. The resulting intratumoral distribution of liposomes following infusion should be taken into account in treatment planning and evaluation in a clinical setting for an optimal cancer therapy.

60 APPLIED LIFE SCIENCES↗

Dosimetric evaluation of new approaches in GRID therapy using nonconventional radiation sources

Purpose: Spatial fractionation of the dose has proven to be a promising approach to increase the tolerance of healthy tissue, which is the main limitation of radiotherapy. A good example of that is GRID therapy, which has been successfully used in the management of large tumors with low toxicity. The aim of this work is to explore new avenues using nonconventional sources: GRID therapy by using kilovoltage (synchrotron) x-rays, the use of very high-energy electrons, and proton GRID therapy. They share in common the use of the smallest possible grid sizes in order to exploit the dose–volume effects. Methods: Monte Carlo simulations (PENELOPE/PENEASY and GEANT4/GATE codes) were used as a method to study dose distributions resulting from irradiations in different configurations of the three proposed techniques. As figure of merit, percentage (peak and valley) depth dose curves, penumbras, and central peak-to-valley dose ratios (PVDR) were evaluated. As shown in previous biological experiments, high PVDR values are requested for healthy tissue sparing. A superior tumor control may benefit from a lower PVDR. Results: High PVDR values were obtained in the healthy tissue for the three cases studied. When low energy photons are used, the treatment of deep-seated tumors can still be performed with submillimetric grid sizes. Superior PVDR values were reached with the other two approaches in the first centimeters along the beam path. The use of protons has the advantage of delivering a uniform dose distribution in the tumor, while healthy tissue benefits from the spatial fractionation of the dose. In the three evaluated techniques, there is a net reduction in penumbra with respect to radiosurgery. Conclusions: The high PVDR values in the healthy tissue and the use of small grid sizes in the three presented approaches might constitute a promising alternative to treat tumors with such spatially fractionated radiotherapy techniques. The dosimetric results presented here support the interest of performing radiobiology experiments in order to evaluate these new avenues.

07 ISOTOPE AND RADIATION SOURCES↗

SU-E-T-620: Planning and Dosimetry for Pulsed Low Dose Rate RT for Recurrent Lung, Spine, GYN and Head and Neck Cancers

Purpose: Extensive in vitro and in vivo studies have shown that pulsed low dose rate (PLDR) radiotherapy has potential to provide significant local tumor control and to reduce normal tissue toxicities. This work investigated the planning and dosimetry of PLDR re-irradiation for recurrent cancers. Methods: We analyzed the treatment plans and dosimetry for 13 recurrent patients who were treated with the PLDR technique in this study. All cases were planned with the 3DCRT technique with optimal beam angle selection. The treatment was performed on a Siemens accelerator using 6MV beams. The target volume ranged between 161 and 703cc. The previous RT dose was 40–60Gy while the re-irradiation dose was 16–60Gy. The interval between previous RT and re-irradiation was 13–336 months, and the follow-up time was up to 27months. The total prescription dose was administered in 2Gy/day fractions with the daily dose delivered in 10 sub-fractions (pulses) of 20cGy with a 3min interval between the pulses to achieve an effective dose rate of 6.7cGy/min. Results: The clinical outcome was analyzed based on the treatment plans. All pulses were kept with Dmax<40cGy. The PLDR treatments were effective (CR: 3 patients, PR: 10 patients). The acute and late toxicities were all acceptable (generally grade II or under). Two patients died three months after the PLDR re-irradiation, one due to massive cerebral infarction and the other due to acute cardiac failure. All others survived more than 8 months. Five patients showed good conditions at the last follow-up. Among them two recurrent lung cancer patients had survived 23 months and one nasopharyngeal cancer patient had survived 27 months. Conclusion: The PLDR technique was effective for the palliative treatment of head and neck, lung, spine and GYN cancers. Further phase II and III studies are warranted to quantify the efficacy of PLDR for recurrent cancers.

61 RADIATION PROTECTION AND DOSIMETRY↗

SU-F-T-683: Cancer Stem Cell Hypothesis and Radiation Treatments

Purpose: The tumor control probability in radiation therapy allows comparing different radiation treatments to each other by means of calculating the probability that a prescribed dose of radiation eradicates or controls the tumor. In the conventional approach, all cancer cells can divide unlimited number of times and the tumor control often means eradicating every malignant cell by the radiation. In recent years however, there is a mounting consensus that in a given tumor volume there is a sub-population of cells, known as cancer stem cells (CSCs) that are responsible for tumor initiation and growth. Other or progenitor cancer cells can only divide limited number of times. This entails that only cancer stem cells may nned to be eliminated in order to control the tumor. Thus one may define TCP as the probability of eliminating CSCs for the given dose of radiation. Methods: Using stochastic methods, specifically the birth-and-death Markov processes, an infinite system of equations is set for probabilities of having m cancer stem cells at time t after the start of radiation. The TCP is calculated as the probability of no cancer stem cells surviving the radiation. Two scenarios are studied. In the first situation, the TCP is calculated for a unidirectional case when CSC gives birth to another CSC or a progenitor cell. In the second scenario, a bidirectional model is studied where the progenitor cell gives rise to CSC. Results: The proposed calculations show that the calculated TCP for CSC depends on whether one adopts unidirectional or bidirectional conversion models. The bidirectional model shows significantly lower TCP values for the given dose delivered to the tumor. Conclusion: Incorporating CSC hypothesis into the TCP modeling may notably influence the dose prescription as well as the concept of the expected TCP after the radiation treatments.

60 APPLIED LIFE SCIENCES↗

Optimization of Lithium Content and Sintering Additives in Tape Cast Lithium Garnet Electrolyte Sheets

The lithium garnet (LLZO) remains one of the most promising electrolyte materials for producing solid state batteries. Tape casting is one method for producing the thin ceramic electrolyte layer required for a high-performance solid state battery. Processing of LLZO is complicated by several factors including lithium volatilization, abnormal grain growth and phase instability. Many of these issues are exacerbated in tape cast sheets by the sheets' higher surface area to volume ratio, when compared to pellet processing methods. Here, we report on an environmentally friendly aqueous tape casting process for LLZO using methylcellulose as a binder and compare final sheet properties to other, solvent-based, options. Solids loading, binder content, dispersant composition, and wetting agent type are varied to improve ease of casting and enhance properties of the as-cast tape. Lithium content in sintered LLZO sheets is controlled by the inclusion of excess Li 2 CO 3 as lithium source in the ceramic tape itself and by a novel method of producing a lithium-saturated furnace atmosphere. Sintering time and temperature are optimized, and rapid thermal processing is investigated as a method of reducing lithium loss. Al 2 O 3 and MgO are examined for use as sintering additives. Characterization of LLZO sheets is performed with XRD, EIS and SEM. Li 2 CO 3 and sintering additive levels are optimized for ionic conductivity and density. The optimization effort improved the conductivity and density of 100µm thick sintered sheets to greater than 3x10 -4 S/cm conductivity and 90% density.

36 MATERIALS SCIENCE↗

Interpreting T-History Data on Supercooling and Phase Change Enthalpy of a Salt-Hydrogel Complex for Building Thermal Management

Phase change materials (PCMs) are promising materials for storing and discharging latent heat in buildings to regulate the thermal environment. Measurement of salt hydrate PCM thermal performance is often challenging because of supercooling and phase segregation. Though differential scanning calorimetry (DSC) has been widely used to measure thermal properties of various phase change materials, DSC uses milligrams of sample and is unrealistic for predicting large-scale materials performance. The T-history method [1], in contrast, handles higher volumes but the analysis typically requires a lumped capacitance assumption. Here, we report and analyze T-History data on a novel salt-hydrogel complex with high viscosity, that renders low Biot number sample preparation extremely challenging. We re-examine the standard T-history method and compared against DSC data in this complex material. We report details of an experimental setup, built with necessary additions to a controlled environmental chamber. We carefully examine the validity of the lumped capacitance assumption and suggest a modified analysis using a computational approach for reliable data. Experimental parameters such as ramp rate and temperature range of the environmental chamber are considered via computational modeling to understand the effect of ramp rate on supercooling [2]. Finally, we report thermal cycling experiments on the salt-hydrogel complex. Our modified approach to measuring supercooling and enthalpy of fusion at large scales is important in better understanding the performance of phase-change materials at scale for building thermal storage. References: [1] Marin, Jose M, Belen Zalba, Luisa F Cabeza, and Harald Mehling. “Determination of Enthalpy Temperature Curves of Phase Change Materials with the Temperature-History Method: Improvement to Temperature Dependent Properties.” Measurement Science and Technology 14, no. 2 (February 1, 2003): 184–89. https://doi.org/10.1088/0957-0233/14/2/305. [2] Safari, A., R. Saidur, F.A. Sulaiman, Yan Xu, and Joe Dong. “A Review on Supercooling of Phase Change Materials in Thermal Energy Storage Systems.” Renewable and Sustainable Energy Reviews 70 (April 2017): 905–19. https://doi.org/10.1016/j.rser.2016.11.272

thermodynamics↗

Analyses of requirements for computer control and data processing experiment subsystems: Image data processing system (IDAPS) software description (7094 version), volume 2

A description of each of the software modules of the Image Data Processing System (IDAPS) is presented. The changes in the software modules are the result of additions to the application software of the system and an upgrade of the IBM 7094 Mod(1) computer to a 1301 disk storage configuration. Necessary information about IDAPS sofware is supplied to the computer programmer who desires to make changes in the software system or who desires to use portions of the software outside of the IDAPS system. Each software module is documented with: module name, purpose, usage, common block(s) description, method (algorithm of subroutine) flow diagram (if needed), subroutines called, and storage requirements.

Source record↗

New features of different frequency generating systems due to the use of electrodeless rigidly mounted VBA quartz crystal resonator

The BVA 5 MHz crystal equipped frequency sources exhibit a new blend of performances such as 10 to 11 daily stability, 5x10-13 short term stability (1 to 30 s time intervals) and close to the carrier low phase noise (1 Hz : -120 dBc, 10 Hz : -140 dBc), whereby retaining the customary crystal oscillator benefits of small volume, high reliability and low price, as opposed to more sophisticated frequency generators which would be required to achieve comparable performances. Examples illustrating the impact of the Oscilloquartz BVA oven-controlled crystal oscillator in different frequency generating systems are presented: cesium frequency standards; hydrogen frequency standard; a precision distribution sub-system for satellite ground stations; and high hierarchy exchanges of digital networks, synchronized by the master-slave method are discussed.

Jendly, A.↗

The design of two sonic boom wind tunnel models from conceptual aircraft which cruise at Mach numbers of 2.0 and 3.0

A method for designing wind tunnel models of conceptual, low-boom, supersonic cruise aircraft is presented. Also included is a review of the procedures used to design the conceptual low-boom aircraft. In the discussion, problems unique to, and encountered during, the design of both the conceptual aircraft and the wind tunnel models are outlined. The sensitivity of low-boom characteristics in the aircraft design to control the volume and lift equivalent area distributions was emphasized. Solutions to these problems are reported; especially the two which led to the design of the wind tunnel model support stings.

Mack, Robert J.↗

Design of an essentially non-oscillatory reconstruction procedure on finite-element type meshes

An essentially non-oscillatory reconstruction for functions defined on finite-element type meshes was designed. Two related problems are studied: the interpolation of possibly unsmooth multivariate functions on arbitrary meshes and the reconstruction of a function from its average in the control volumes surrounding the nodes of the mesh. Concerning the first problem, we have studied the behavior of the highest coefficients of the Lagrange interpolation function which may admit discontinuities of locally regular curves. This enables us to choose the best stencil for the interpolation. The choice of the smallest possible number of stencils is addressed. Concerning the reconstruction problem, because of the very nature of the mesh, the only method that may work is the so called reconstruction via deconvolution method. Unfortunately, it is well suited only for regular meshes as we show, but we also show how to overcome this difficulty. The global method has the expected order of accuracy but is conservative up to a high order quadrature formula only. Some numerical examples are given which demonstrate the efficiency of the method.

Abgrall, R.↗

New Technique of High-Performance Torque Control Developed for Induction Machines

Two forms of high-performance torque control for motor drives have been described in the literature: field orientation control and direct torque control. Field orientation control has been the method of choice for previous NASA electromechanical actuator research efforts with induction motors. Direct torque control has the potential to offer some advantages over field orientation, including ease of implementation and faster response. However, the most common form of direct torque control is not suitable for the highspeed, low-stator-flux linkage induction machines designed for electromechanical actuators with the presently available sample rates of digital control systems (higher sample rates are required). In addition, this form of direct torque control is not suitable for the addition of a high-frequency carrier signal necessary for the "self-sensing" (sensorless) position estimation technique. This technique enables low- and zero-speed position sensorless operation of the machine. Sensorless operation is desirable to reduce the number of necessary feedback signals and transducers, thus improving the reliability and reducing the mass and volume of the system. This research was directed at developing an alternative form of direct torque control known as a "deadbeat," or inverse model, solution. This form uses pulse-width modulation of the voltage applied to the machine, thus reducing the necessary sample and switching frequency for the high-speed NASA motor. In addition, the structure of the deadbeat form allows the addition of the high-frequency carrier signal so that low- and zero-speed sensorless operation is possible. The new deadbeat solution is based on using the stator and rotor flux as state variables. This choice of state variables leads to a simple graphical representation of the solution as the intersection of a constant torque line with a constant stator flux circle. Previous solutions have been expressed only in complex mathematical terms without a method to clearly visualize the solution. The graphical technique allows a more insightful understanding of the operation of the machine under various conditions.

Kenny, Barbara H.↗

Vector-Ordering Filter Procedure for Data Reduction

The vector-ordering filter (VOF) technique involves a procedure for sampling a large population of data vectors to select a subset of data vectors that fully characterize the state space of the large population. The VOF technique enables a large reduction of the volume of data that must be handled in the automated monitoring system and method discussed in the two immediately preceding articles. In so doing, the VOF technique enables the development of data-driven mathematical models of a monitored asset from sets of data that would otherwise exceed the memory capacities of conventional engineering computers. Data-driven mathematical models have been shown to offer high fidelity for purposes of control and monitoring of assets. In practice, a collection of asset-operating observations is acquired with the intention that the collection contain observations characteristic of the full dynamic range of operation of the asset. Often, such a collection contains an extremely large number of observations, many of which are redundant. The VOF technique fills the need for a means to extract, from the original collection of observational data, a reduced data matrix that excludes redundant data while maintaining the full statistical character and dynamic range of the original data. The reduced data matrix can then be used as the input data for development of a mathematical model of the monitored asset, or as training data for a neural-network substitute for an explicit mathematical model of the asset. Alternatively, the reduced data matrix can, itself, be used directly as a mathematical model of the monitored asset, as is commonly done in multivariate state-estimation techniques. The original data are collected from the asset over a range of operating states and are put in matrix form. Each column vector in the original data matrix represents the signal values acquired at a particular operational state of the asset. Thus, the number of columns of the original data matrix equals the number of observed states and the number of rows in this matrix equals the number of signals acquired at each observation. In the VOF technique, one extracts the reduced data matrix from the original data matrix through the selection of a representative subset of the column (state) vectors.

Bickford, Randall L.↗

Synthesis and characterization of pharmaceutical surfactant templated mesoporous silica: Its application to controlled delivery of duloxetine

Graphical abstract: - Highlights: • Usefulness of dual pharmaceutical surfactants in silica synthesis was evaluated. • Effects of concentration of secondary template (Tween-40) were studied. • Effects of fixed solvothermal condition on mesostructure formation were studied. • Duloxetine drug loading capability was studied. • Sustained release of duloxetine was evaluated. - Abstract: A new group of mesoporous silica nanoparticles (MSNs) were synthesized using combination pharmaceutical surfactants, Triton X-100 and Tween-40 as template and loaded with duloxetine hydrochloride (DX), for improving the sustained release of DX and patterns with high drug loading. Agglomerated spherical silica MSNs were synthesized by sol–gel and solvothermal methods. The calcined and drug loaded MSNs were characterized using X-ray diffraction (XRD), Braunner–Emmett–Teller (BET), thermogravimetric analysis (TGA), Fourier-transform infrared (FT-IR) spectroscopy, scanning electron microscopy (SEM), differential scanning calorimetry (DSC), diffuse reflectance ultraviolet–visible (DRS-UV–vis) spectroscopy. MSNs with high surface area and pore volume were selected and studied for their DX loading and release. The selected MSNs can accommodate a maximum of 34% DX within it. About 90% was released at 200 h and hence, the synthesized MSNs were capable of engulfing DX and sustain its release. Further form the Ritger and Peppas, Higuchi model for mechanism drug release from all the MSN matrices follows anomalous transport or Non-Fickian diffusion with the ‘r’ and ‘n’ value 0.9 and 0.45 < n < 1, respectively. So, from this study it could be concluded that the MSNs synthesized using pharmaceutical templates were better choice of reservoir for the controlled delivery of drug which requires sustained release.

36 MATERIALS SCIENCE↗

A Lagrangian particle method with remeshing for tracer transport on the sphere

A Lagrangian particle method (called LPM) based on the flow map is presented for tracer transport on the sphere. The particles carry tracer values and are located at the centers and vertices of triangular Lagrangian panels. Remeshing is applied to control particle disorder and two schemes are compared, one using direct tracer interpolation and another using inverse flow map interpolation with sampling of the initial tracer density. Test cases include a moving-vortices flow and reversing-deformational flow with both zero and nonzero divergence, as well as smooth and discontinuous tracers. We examine the accuracy of the computed tracer density and tracer integral, and preservation of nonlinear correlation in a pair of tracers. Here, we compare results obtained using LPM and the Lin–Rood finite-volume scheme. An adaptive particle/panel refinement scheme is demonstrated.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Adaptable SEC‐SAXS data collection for higher quality structure analysis in solution

Abstract The two major challenges in synchrotron size‐exclusion chromatography coupled in‐line with small‐angle x‐ray scattering (SEC‐SAXS) experiments are the overlapping peaks in the elution profile and the fouling of radiation‐damaged materials on the walls of the sample cell. In recent years, many post‐experimental analyses techniques have been developed and applied to extract scattering profiles from these problematic SEC‐SAXS data. Here, we present three modes of data collection at the BioSAXS Beamline 4–2 of the Stanford Synchrotron Radiation Lightsource (SSRL BL4‐2). The first mode, the High‐Resolution mode, enables SEC‐SAXS data collection with excellent sample separation and virtually no additional peak broadening from the UHPLC UV detector to the x‐ray position by taking advantage of the low system dispersion of the UHPLC. The small bed volume of the analytical SEC column minimizes sample dilution in the column and facilitates data collection at higher sample concentrations with excellent sample economy equal to or even less than that of the conventional equilibrium SAXS method. Radiation damage problems during SEC‐SAXS data collection are evaded by additional cleaning of the sample cell after buffer data collection and avoidance of unnecessary exposures through the use of the x‐ray shutter control options, allowing sample data collection with a clean sample cell. Therefore, accurate background subtraction can be performed at a level equivalent to the conventional equilibrium SAXS method without requiring baseline correction, thereby leading to more reliable downstream structural analysis and quicker access to new science. The two other data collection modes, the High‐Throughput mode and the Co‐Flow mode, add agility to the planning and execution of experiments to efficiently achieve the user's scientific objectives at the SSRL BL4‐2.

Matsui, Tsutomu↗

Minimized Doses for Linear Accelerator Radiosurgery of Brainstem Metastasis

Purpose: Treatment of cerebral metastases located inside the brainstem remains a challenge, as the brainstem is considered to be a neurological organ at risk, whatever the treatment strategy. We report a retrospective study of 30 consecutive patients treated in our institution between 2005 and 2007 with micromultileaf linear accelerator (LINAC) -radiosurgery for brainstem metastases, with reduced doses compared to those usually reported in the literature. Methods and Materials: Mean follow-up was 311 days (range, 41-1351). Median age was 57 years (range, 37-82), Mean Karnofsky Index (KI) was 80. Primary tumor site was lung (n = 13), breast (n = 4), kidney (n = 4), skin (melanoma; n = 3), and others (n = 6). Primary tumor was controlled in 17 cases; extracranial metastases were controlled in 12 cases. Mean number of metastases was 1.46 (one to three); median volume was 2.82 cc (0.06-18). Dose was delivered by a micromultileaf collimator 6-MV LINAC . Results: Dose administered at the 70% isodose was 13.4 Gy (range, 8.2-15). Median survival was 10 months. Local control rates at 3, 6, and 12 months were 100%, 100%, and 79% respectively. Median neurological control duration was 5 months. Neurological control rates at 3, 6, and 12 months were 73%, 42%, and 25%, respectively. No parameter was found to significantly correlate with survival, local, or cerebral control. No patients had severe side effects (Grade III-IV), according to the Radiation Therapy Oncology Group (RTOG) scale. Conclusion: Lower doses than previously reported can achieve the same local control and survival rates in brain metastases, with minimal side effects.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Mapping the effects of physical and chemical reduction parameters on local atomic distributions within bimetallic nanoparticles

Bimetallic nanoparticles prove advantageous over their monometallic counterparts due to the tunable, hybrid properties that result from combining different atomic species in a controlled way. The favorable optical and catalytic properties resulting from AgAu nanoparticle formation have been widely attributed to the existence of Ag–Au bonds, the maximization of which assumes the formation of a homogeneous alloy. Despite the importance of atomic scale structure in these systems, synthetic studies are typically not paired with structural characterization at the atomic scale. Herein, a comprehensive synthetic exploration of physical and chemical reduction parameters of resulting nanoparticle products is complemented with thorough X-ray characterization to probe how these parameters affect atomic scale alloy distributions within AgAu nanoparticles. Presented evidence shows Ag is substantially underincorporated into nanoparticle constructs compared with solution Ag : Au ratios regardless of precursor :reductant ratio or volume of reductant added. Both Ag and Au exhibit significant local clustering, with Ag distributed preferentially towards the nanoparticle surface. Most significantly, the results of this investigation suggest that reduction parameters alone can affect the local alloy distributions and homogeneity within bimetallic nanoparticles, even when the ratio of metallic precursors remains constant. Overall, this investigation presents the ability to control alloy distributions using kinetics and provides new considerations for optimizing synthetic methods to produce functional bimetallic nanoparticles.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Demonstration of a Novel Phase-Space Painting Method in a Coupled Lattice to Mitigate Space Charge in High-Intensity Hadron Beams

Multiturn charge-exchange injection is the primary method of creating high-intensity hadron beams in circular accelerators, and phase space painting during injection enables tailoring of the accumulated phase space distribution. A technique we call eigenpainting allows injection of particles into a single mode of a coupled ring, providing full four-dimensional control of the phase space distribution. Under ideal conditions, uniform eigenpainting generates a linear-force equilibrium distribution in the transverse plane, with zero volume in four-dimensional transverse phase space, even including space charge. Here, we have implemented eigenpainting for the first time in the spallation neutron source accumulator ring. Injecting 8.8 μ⁢C of an 800 MeV beam, we obtain a final ratio of intrinsic transverse emittances of ≈2.4. We analyze the effect of space charge on the final distribution through comparison of the reconstructed phase space to particle-in-cell simulations.

Evans, Nicholas J. [Oak Ridge National Laboratory ↗