Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “condition monitoring”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 847 records · Page 47

On-Line Modal State Monitoring of Slowly Time-Varying Structures

Monitoring the dynamic response of structures is often performed for a variety of reasons. These reasons include condition-based maintenance, health monitoring, performance improvements, and control. In many cases the data analysis that is performed is part of a repetitive decision-making process, and in these cases the development of effective on-line monitoring schemes help to speed the decision-making process and reduce the risk of erroneous decisions. This report investigates the use of spatial modal filters for tracking the dynamics of slowly time-varying linear structures. The report includes an overview of modal filter theory followed by an overview of several structural system identification methods. Included in this discussion and comparison are H-infinity, eigensystem realization, and several time-domain least squares approaches. Finally, a two-stage adaptive on-line monitoring scheme is developed and evaluated.

Johnson, Erik A.↗

Quantifying Properties for a Mechanistic, Predictive Understanding of Aqueous Impact on Aging of Medium and Low Voltage AC and DC Cabling in Nuclear Power Plants

To address the gap in knowledge in understanding degradation in relevant service conditions, this project aimed to develop a mechanistic, predictive model of medium and low voltage cable failure based on the primary environmental degradation parameters of aqueous immersion time, temperature, and the oxidation extent. To do so, we took a two-fold approach toward evaluating degradation as related to the aqueous condition. First, we evaluated the chemical, mechanical, and electrical properties of polymers that comprise the cabling insulation under varied aqueous conditions at different temperatures. Secondly, we evaluated the performance of insulation materials under similar accelerated aging conditions in addition to the dielectric breakdown of the cabling under submersion conditions. Thermal oxidation and immersion of LDPE thin films were done using a Parr vessel and the extent of oxidation was monitored using the carbonyl index from ATR-FTIR spectrum, a ratio quantifying the carbonyl functionality produced on the LDPE film surface. Increasing the temperature, oxidation time, and oxygen pressure increased the water-vapor permeability and the carbonyl content. Thermogravimetric analysis of the films confirmed that there is indeed an initial weight loss of the smaller molecular weight molecules and volatiles. At higher temperatures, there is a secondary mass loss. Up to 70°C, the mass loss curves were similar until 80°C, when the aged films decreased at a much greater rate with respect to increasing temperature. This was seen in the 10, 50, 90% weight loss temperatures. The mechanical properties of sheet PP and HDPE as well as injection molded LDPE, HDPE, HDPP dog bones were plotted with respect to the time spent in the Parr vessel during thermal oxidation. For the sheet PP and HDPE, the UTS and the modulus of elasticity decreased while the elongation increased. The injection-molded LDPE, HDPE, and HDPP dog bones experienced a similar trend where the changes in the properties were within experimental uncertainty. This analysis of LDPE in dry and immersive oxygen-rich environments is an important baseline for future experiments looking at other degradation mechanisms. A predictive aging model for low-density polyethylene insulative cable housings was developed. This model revealed a combination of physical and chemical processes which lead to an increase in permeability and a decrease in strength of the insulator. In creating this predictive model, a gap of knowledge in the literature was revealed in two areas: understanding how the crystallinity of a polymer changes with time and visualizing the predicted pores formed through the insulator which leads to failure. Developing and using an adapted ATR-FTIR method, crystallinity was monitored and compared to bulk crystallinity found via DSC. Inhomogeneity in crystallinity changes were observed but the FTIR method but was found to be less reliable. Pore visualization was found utilizing electrical impedance spectroscopy saturated aged polyethylene films with synthesized citrate-capped gold nanoparticles, and chloroauric acid precursor. results indicate a decreasing impedance of the polyethylene films caused by the transport of ions through the film. SEM imaging was then performed for elemental analysis of the films and counter electrodes for the presence of ions. Chloride and gold ions were detected; however, no nanoparticles were found. This gives an estimated pore size of at least 0.3 nm through the aged film. Cyclic submergence of polyethylene and polypropylene in aqueous solutions of copper sulfate and Harrison’s solution were examined. It was discovered that aging in these mixed conditions and at 90°C did cause a small, yet significant increase to tensile strength for both unaged polyethylene and polypropylene. The PE and PP in cycled and submerged conditions did not have tensile strengths significantly different from dry-aged after 16 weeks. For both solutions, it was determined that capacitance increases with both water tree depth and cable temperature and is relatively independent of changing water tree AR. As for resistance, there is no apparent change between depth percentages of 10 and 80 for both solutions. This is because the water tree has not yet entered the conductor and thus there is no shorting current flowing through the tree yet. Between 80 and 100% water tree depth, it is observed that for both solutions there is a rapid decrease in resistance because the tree is now impacting the conductor shield and allowing shorting current to flow through it. The relationship between resistance and temperature was found to be inversed. As temperature increases, resistance decreases for both water tree solutions with distilled water having the most apparent difference across the range of temperatures simulated. With regards to water tree AR, resistance was found to be relatively independent at depth percentages of 10, 50, and 70, but there was some relationship at 100% depth for both solutions. At this depth, as water tree AR increased, resistance was found to also increase. Through the examination of voltage and electric field distribution plots, it was confirmed for EPR cables that increasing water tree depth leads to increasing distortion. The increase in shorting current at 100% depth for aqueous copper sulfate compared to distilled water was also visualized. Lastly, the relationship between shorting current and temperature for narrow water trees was visualized and validated using the distribution plots. This study has led to a better understanding of the effect of cable temperature, water tree solution, and geometry of the tree region on cable degradation. Furthermore, this study has documented simulation results of water tree degradation in EPR MV cables, which had been previously lacking in information. Future work in this area will add frequency into the mix and examine what effect it has on the rate of cable degradation as a result of water treeing. To compliment the work being carried by UMD on different polymer chemistries, harvested medium voltage (MV) cables were selected for accelerated aging study at ORNL. These medium voltage cables are representative of the vintages and materials that are currently in use at existing nuclear power plants (NPPs). These cables were immersed in water at 90°C and energized for a period of two years at elevated voltage. Partial discharge was measured during this period of time to track potential degradation. Unfortunately, due to the absence of failure, the extent of integration between the UMD techniques and the harvested MV insulation was limited. However, based on the findings and from the UMD research in the previous sections on polyethylene and polypropylene, follow-on characterization for harvested MV cable insulation should focus on sample preparation to take advantage of the UMD techniques to better understand mechanistic degradation in MV cable insulations. This would include: 1.) Utilization of solutions and impedance measurement insulation to track permeability in harvested and accelerated aging insulation samples, 2.) Adaptation of gold nanoparticle synthesis for electrical impedance spectroscopy with supporting SEM characterization to study pore formation in harvested and accelerated aged insulation samples, & 3.) ATR-FTIR crystallinity with multiple temperature dependent harvested MV cable insulation under different air and submerged accelerated aging. In addition, low voltage dielectric spectroscopy and high voltage dissipation factor, tan δ, could be implemented as a condition monitoring tool for harvested MV cable insulation in submerged environments.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Using LANDSAT digital data for estimating green biomass

The author has identified the following significant results. Relationships between the quantity of mixed prairie rangeland vegetation and LANDSAT MSS response were studied during four growing seasons at test sites throughout the United States Great Plans region. A LANDSAT derived parameter, the normalized difference was developed from theoretical considerations fro statistical estimation of the amount and seasonal condition of rangeland vegetation. This parameter was tested for application to local assessment of green forage biomass and regional monitoring of range feed conditions and drought. Results show that for grasslands in the Great Plains with near continuous vegetative cover and free of heavy brush and forbs, the LANDSAT digital data can provide a useful estimate of the quantity of green forage biomass (within 250 kg/ha), and at least five levels of pasture and range feed conditions can be adequately mapped for extended regions.

Deering, D. W.↗

Distributed Optical Fiber Sensor Systems: Application to Natural Gas Pipeline Monitoring

Distributed fiber optic sensing is a cutting-edge technology that has found extensive applications in the monitoring of pipelines. Considering the low backscattering level of standard single-mode fiber as fiber under test, a Rayleigh enhanced optical fiber embedded within the tight-buffered cable is demonstrated in field testing. We analyzed the increased backscattering fiber cable's vibration performance to the conventional single-mode telecom fiber using a custom-built Φ-OTDR interrogator system. Thereafter, using a 4-inch steel pipeline with a flow rate of 5, 10, 15, and 20 ft/s and a fixed pressure level of 1000 psi, we field-tested the sensor system for monitoring natural gas pipeline acoustic vibrations. We also field tested Brillouin optical time domain analysis (BOTDA) system for pipeline hoop strain monitoring under various pressure conditions. The pilot-scale testing results presented in this study suggested that pipeline operators can accurately perform flow monitoring, leak detection, and pressure monitoring for pipeline integrity monitoring.

Lalam, Nageswara↗

Chemical and Radiological Compatibility Testing of 3D Printed Materials

To dramatically increase the adaptability, performance, and safety of processes in support of the Defense Waste Processing Facility (DWPF), Savannah River National Lab (SRNL) plans to perform chemical and radiological compatibility testing on a wide variety of 3D printed materials of interest. The 3D printing process provides numerous strategic operational benefits such as rapid prototyping of complex designs and geometry specific to the needs of the nuclear waste disposition process, as well as on-demand rapid prototyping and iteration with materials that aren’t as accessible through traditional manufacturing methods. Reaction chemistry in simulated waste batches can be matched closely to its radioactive counterpart, but glass reactor vessels have limitations. Vessel geometry can play a big factor in mixing transport limitations, process chemistry, and degradation reaction kinetics. In addition, additive manufacturing allows for much more detailed vessel design than traditional alternatives. Waste processing techniques in DWPF also encounter extreme chemical environments including high pH, strong acids, abrasive slurries, and significant irradiation. To meet these challenges, a matrix of various polymer, ceramic, and metal additive manufacturing materials have been exposed to a suite of chemical environments of interest as well as radioactive dose (such as gamma radiation from 60 Co) to properly test their durability under these conditions. Mass change has been monitored over a period of up to a week in these conditions, as well as added characterization for surface modification through Scanning Electron Microscopy/Electron Dispersive X-ray analysis (SEM/EDX). Further chemical characterization has been monitored through Fourier-Transform InfraRed Spectroscopy (FTIR), with planned investigation via thermal and tensile strength degradation. While the direct product of this research is identification of material(s) that can withstand specific hazardous environments encountered by the mercury water wash tank in DWPF process simulation experiments, the reference base of materials will be used for many other nuclear processes in the pursuit of rapidly developed, cost-efficient, and highly specific devices for environmental remediation and much more.

Wilson, Nathan W. [Savannah River National Laborat↗

Technical Assessment of Off-Gas System Technologies for Potential Use in Molten Salt Reactors

Molten salt reactors (MSRs) are a class of Generation IV advanced reactor technologies aimed to enhance and improve the safety, fuel utilization and cost-effectiveness of nuclear power generation. MSR concepts are based on using a molten salt mixture as a primary nuclear reactor coolant, while the fuel can be either directly dissolved in the coolant (i.e., fluid-fueled) or can be in a separate solid form (i.e., salt-cooled solid-fueled). MSRs can be operated in either thermal or fast neutron spectra, as simple fissile convertors, or breeder reactors (e.g., utilizing both fissile and fertile fuels), as well as accelerator-driven sub-critical reactors or transuranic element burners. Operation of MSRs will necessitate management and treatment of the off-gas streams released to the headspace of the reactor where, in some designs, a cover gas can be circulated to remove certain fission products and maintain an inert atmosphere. An inert MSR cover gas swept over or sparged into the salt will confine radionuclides emerging from the free surface, including radioactive noble and non-noble gases, aerosols, and volatile species. The elements and compounds of these species will have a wide range of thermochemical and physical properties, some of which will decay to different products in the off-gas stream. Therefore, system components used to manage and treat MSR off-gas streams will need to be robust under dynamic reactor and chemistry conditions to support adequate reactor performance by managing the composition and species in the salt coolant and cover gas space. Off-gas system components would perform as a radionuclide boundary to the reactor vessel and a primary means for preventing radionuclide release; therefore, they are of high safety significance for MSR operations. This report reviews various technologies and materials for potential implementation in the design of an MSR off-gas system per a general conceptual framework. The reviewed technologies operate based on scrubbing, capture, delay, or separation of species in the off-gas stream. These include molten hydroxide scrubbers, solid sorbents, delay off-gas systems, particle traps, and cryogenic distillation. Since aspects of an off-gas system will be design-specific, the approach is to provide general discussions on attributes of these technologies and materials, including target off-gas stream species, operational parameters and conditions of importance to decontamination factors, implementation maturity, system component monitoring, potential off-normal conditions and considerations for waste products. The information aims to support the U.S. Nuclear Regulatory Commission in their safety evaluations for MSR designs.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Likelihood alarm displays

In a likelihood alarm display (LAD) information about event likelihood is computed by an automated monitoring system and encoded into an alerting signal for the human operator. Operator performance within a dual-task paradigm was evaluated with two LADs: a color-coded visual alarm and a linguistically coded synthetic speech alarm. The operator's primary task was one of tracking; the secondary task was to monitor a four-element numerical display and determine whether the data arose from a 'signal' or 'no-signal' condition. A simulated 'intelligent' monitoring system alerted the operator to the likelihood of a signal. The results indicated that (1) automated monitoring systems can improve performance on primary and secondary tasks; (2) LADs can improve the allocation of attention among tasks and provide information integrated into operator decisions; and (3) LADs do not necessarily add to the operator's attentional load.

Sorkin, Robert D.↗

Iron Behavior in Microcosms Simulating Bioreduction in Savannah River Site Sediments - 17389

An estimated 1.8 billion gallons of acidic low-activity waste solutions originating from the processing of uranium slugs and irradiated fuel at separation facilities at the Savannah River Site (SRS) were discharged to the unlined seepage basins located in the F/H-area. The acidic solutions of the basin influent (pH from 3.2 to 5.5) contaminated with a variety of radionuclides and dissolved metals caused groundwater contamination. In 2010, DOE funded a demonstration of the Enhanced Anaerobic Reductive Precipitation (EARP) process at the SRS F-Area that consisted of in-situ injections of a carbohydrate substrate to establish anaerobic reactive zones for metal and radionuclide remediation. The addition of the molasses substrate solution to groundwater was done to produce anaerobic conditions conducive to uranium reduction and then precipitation as uranium (IV). The SRS soil is highly weathered and features very low natural alkalinity. A microcosm study, prepared with sieved SRS sediments and augmented with a solution mixture containing molasses and sulfate, was designed to provide evidence of the capabilities of this remediation technology under SRS environmental conditions. The objective of these microcosm experiments was to replicate the anaerobic conditions created as a result of injections of molasses combined with sulfate ions, similar to the EARP process that was performed at SRS, and investigate if any mineralogical changes could occur in the soil due to the addition of molasses. Specifically, the study aimed to determine if solid phases of reduced iron such as siderite and pyrite would be formed, as this would indicate the potential to form a long-lasting bioreductive zone. An understanding of this technology will be useful in determining if it is a viable option for remediation. In the experiments, the media solution was amended with molasses and sulfate to stimulate sulfate-reducing bacteria. Sulfate reduction occurs extensively under the redox conditions occurring after iron reduction and before methanogenic conditions. These conditions are considered the second most reducing condition in natural groundwater systems. Microcosm tubes prepared in triplicate were kept inside an anaerobic glove box, which was continuously monitored to ensure that conditions remained anaerobic. The initial X-ray diffraction (XRD) analyses on the background sediment samples indicated the presence of quartz, kaolinite, montmorillonite, and goethite. In the molasses-treated samples there were no visible peaks for reduced forms of iron such as siderite and pyrite. The pH measurements suggest that all samples in either batch, including those that were brought to a neutral pH before the addition of the sediments, have followed a similar trend with a decline in the pH value to between 4 and 4.7. This can be attributed to the fermentation of molasses and the natural acidity of the SRS sediments used for the microcosm study. In the acidic iron-rich sediment, the microbial reduction of Fe (III) was the predominant electron-accepting process for oxidation of the organic substrate. The maximum iron concentration detected during the experiments was 13 mg/L. Analytical results showed that there was no sulfate reduction in any of the samples augmented with sulfate and the concentration remained level at 500 ppm as originally added to the initial solutions (518 - 542 mg/L). This is consistent with the absence of any indication of iron sulfide formation. Under the experimental conditions in these microcosms, the abundance of biologically available Fe (III) allows Fe (III)-reducers to out-compete sulfate-reducing bacteria using molasses as an electron donor. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Microbial Monitoring and the Risk of Infectious Disease Aboard the International Space Station

The International Space Station (ISS) is a semi-closed habitat in low Earth orbit with environmental conditions provided by an advanced life support system that controls temperature and recycles air and most of the potable water. The crew's activities, such as eating, sleeping, hygiene, and laboratory research, are performed in relatively close proximity. Research in the laboratory includes a myriad of experiments, including those with rodents, plants, and pathogenic microorganisms. Despite these conditions, in-flight monitoring of ISS indicates that the microbial diversity is similar to homes on earth. Accordingly, the crew is generally very healthy, however infectious disease does occur and potential routes of infection by obligate and opportunistic pathogens cannot be completely prevented. Determining the extent of this risk is further complicated, as microorganisms can alter their characteristics in response to spaceflight culture, as exemplified by the increase in virulence of the enteric pathogen Salmonella enterica Typhimurium during spaceflight compared to otherwise identical cultures grown on Earth. Taken together, these factors suggest a need for continued microbiological monitoring and research to understand and mitigate the risk of infectious disease during long duration missions.

Ott, C. Mark↗

Analysis of the Trip of a High-Power Turbine-Generator of a Nuclear Power Plant Upon Damage of the Stator Winding Insulation According to Data of Monitoring and Modeling

The operating conditions of a turbine-generator with the stator winding short-circuited to the frame are analyzed. The features of the shape of the zero-sequence voltage during arcing in the damaged gap are described. The operation of the relay protection in these conditions is analyzed. The real oscillograms of the subsequent suppression of the rotor field are theoretically justified. It is shown that improving the thyristor excitation system is necessary and possible.

42 ENGINEERING↗

Development of spiral-groove self-acting face seals

An experimental evaluation and a 100-hour endurance test were performed on a spiral groove geometry, self-acting face seal. The seal was tested and operated successfully at maximum conditions of 243.8 m/s surface speed, 199.9 N/sq cm air pressure, and 645.4K (702 F) air temperature. The maximum speed condition of 243.8 m/s was obtained at a shaft speed of 72,500 rpm. Seal wear, gas leakage, and sealing element temperature were monitored during the test. Condition of the seal at the completion of the test was documented and found acceptable for further use. The spiral groove wear rate measured during the endurance test indicates a minimum potential seal life of over 2700 hours. Seal air leakage measured during the test program is within the range considered acceptable for consideration for use in a small gas turbine engine.

Obrien, M.↗

Design of BLDC Motor Diagnostic Device Based on Surge Test for Phase to Ground Fault

BLDC motor is essential in the industrial world, especially it been used for an electric vehicle. The benefit of using BLDC motor is that it has high rate efficiency and low mechanical losses. However, to know the isolation condition of winding and increase reliability, it needs to be tested. With the implementation of surge test based fault detection device of BLDC motor, the condition of BLDC motor can be monitored and maintained according to analysis of its condition. The surge test method used because it is sensitive in detecting the initial damage in the isolation failure process on stator winding. A surge voltage is generated from the Cockroft-Walton and switching circuit with capacitors. The result is analyzed using Error Area Ratio (EAR). The test result shows that the higher the value of resistance and inductance, the smaller the frequency of the surge wave. When the BLDC motor in a parallel short circuit condition, the threshold value of the EAR test-reff has a minimum value of 5.28%, an average of 13.52%, and a maximum of 28.55%.

BLDC motor↗

Monitoring by Use of Clusters of Sensor-Data Vectors

The inductive monitoring system (IMS) is a system of computer hardware and software for automated monitoring of the performance, operational condition, physical integrity, and other aspects of the health of a complex engineering system (e.g., an industrial process line or a spacecraft). The input to the IMS consists of streams of digitized readings from sensors in the monitored system. The IMS determines the type and amount of any deviation of the monitored system from a nominal or normal ( healthy ) condition on the basis of a comparison between (1) vectors constructed from the incoming sensor data and (2) corresponding vectors in a database of nominal or normal behavior. The term inductive reflects the use of a process reminiscent of traditional mathematical induction to learn about normal operation and build the nominal-condition database. The IMS offers two major advantages over prior computational monitoring systems: The computational burden of the IMS is significantly smaller, and there is no need for abnormal-condition sensor data for training the IMS to recognize abnormal conditions. The figure schematically depicts the relationships among the computational processes effected by the IMS. Training sensor data are gathered during normal operation of the monitored system, detailed computational simulation of operation of the monitored system, or both. The training data are formed into vectors that are used to generate the database. The vectors in the database are clustered into regions that represent normal or nominal operation. Once the database has been generated, the IMS compares the vectors of incoming sensor data with vectors representative of the clusters. The monitored system is deemed to be operating normally or abnormally, depending on whether the vector of incoming sensor data is or is not, respectively, sufficiently close to one of the clusters. For this purpose, a distance between two vectors is calculated by a suitable metric (e.g., Euclidean distance) and "sufficiently close" signifies lying at a distance less than a specified threshold value. It must be emphasized that although the IMS is intended to detect off-nominal or abnormal performance or health, it is not necessarily capable of performing a thorough or detailed diagnosis. Limited diagnostic information may be available under some circumstances. For example, the distance of a vector of incoming sensor data from the nearest cluster could serve as an indication of the severity of a malfunction. The identity of the nearest cluster may be a clue as to the identity of the malfunctioning component or subsystem. It is possible to decrease the IMS computation time by use of a combination of cluster-indexing and -retrieval methods. For example, in one method, the distances between each cluster and two or more reference vectors can be used for the purpose of indexing and retrieval. The clusters are sorted into a list according to these distance values, typically in ascending order of distance. When a set of input data arrives and is to be tested, the data are first arranged as an ordered set (that is, a vector). The distances from the input vector to the reference points are computed. The search of clusters from the list can then be limited to those clusters lying within a certain distance range from the input vector; the computation time is reduced by not searching the clusters at a greater distance.

Iverson, David L.↗

An Advanced Extreme Environment Wireless Telemetry System for Turbine Blade Instrumentation

As advanced natural gas power generation systems evolve, the thrust for increased efficiencies and reduced emissions results in increasingly harsh conditions inside the turbine environment. These high temperatures, pressures, and corrosive atmospheres result in accelerated rates of degradation, leading to failure of turbine materials and components. The University of Arkansas (UA) and Siemens, in collaboration with the DoE's National Energy Technology Laboratory (NETL), are developing a reliable and long-term monitoring capability in the turbine hot gas path in the form of novel ceramic-based thermocouples and integrated wide band gap instrumentation electronics that will contribute to the overall reliability of gas turbines. When equipped with better monitoring and controls, power plants can operate with increased fuel-burning efficiency, improved process dynamics and gas concentrations, and increased overall longevity of the power plant components. This will result in increased turbine availability and a reduction in outages and maintenance costs. One of the key aspects to driving forward turbine monitoring capability is the development of high temperature capable integrated circuit (IC) electronics. Previous papers have described 500 °C + electronics that were developed primarily from a combination of discrete single transistors combined with supporting high temperature passive components. While these circuits have been tested successfully in high temperature spin test environments, the move to an IC approach will greatly increase the performance and reliability of turbine monitoring systems. This program is developing such capability through the implementation of silicon carbide (SiC) based ICs, and this paper details the initial approach and early testing of the developed devices. This research represents an important step towards the realization of a field deployable high reliability turbine condition monitoring system.

47 OTHER INSTRUMENTATION↗

Metrological analysis of a virtual flowmeter-based transducer for cryogenic helium

The metrological performance of a virtual flowmeter-based transducer for monitoring helium under cryogenic conditions is assessed. At this aim, an uncertainty model of the transducer, mainly based on a valve model, exploiting finite-element approach, and a virtual flowmeter model, based on the Sereg-Schlumberger method, are presented. The models are validated experimentally on a case study for helium monitoring in cryogenic systems at the European Organization for Nuclear Research (CERN). The impact of uncertainty sources on the transducer metrological performance is assessed by a sensitivity analysis, based on statistical experiment design and analysis of variance. In this way, the uncertainty sources most influencing metrological performance of the transducer are singled out over the input range as a whole, at varying operating and setting conditions. This analysis turns out to be important for CERN cryogenics operation because the metrological design of the transducer is validated, and its components and working conditions with critical specifications for future improvements are identified.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Microminiaturized, biopotential conditioning system (MBCS)

Multichannel, medical monitoring system allows almost complete freedom of movement for subject during monitoring periods. System comprises monitoring unit (biobelt), transmission line, and data acquisition unit. Belt, made of polybenzimidizole fabric, is wrapped around individual's waist and held in place by overlapping sections of Velcro closure material.

Belasco, N.↗

Innovative Strategy For Long Term Monitoring Of Metal And Radionuclide Plumes

Many government and private industry sites that were once contaminated with radioactive and chemical wastes cannot be cleaned up enough to permit unrestricted human access. The sites will require long term management, in some cases indefinitely, leaving site owners with the challenge of protecting human health and environmental quality at these "legacy" sites. Long-term monitoring of groundwater contamination is one of the largest projected costs in the life cycle of environmental management at the Savannah River Site, the larger DOE complex, and many large federal and private sites. There is a need to optimize the performance and manage the cost of long term surveillance and monitoring at their sites. Currently, SRNL is initiating a pilot field test using alternative protocols for long term monitoring of metals and radionuclides. A key component of the approach is that monitoring efforts are focused on measurement of low cost metrics related to hydrologic and chemical conditions that control contaminant migration. The strategy combines careful monitoring of hydrologic boundary conditions with measurement of master variables such as chemical surrogates along with a smaller number of standard well analyses. In plumes contaminated with metals, master variables control the chemistry of the groundwater system, and include redox variables (ORP, DO, chemicals), pH, specific conductivity, biological community (breakdown/decay products), and temperature. Significant changes in these variables will result in conditions whereby the plume may not be stable and therefore can be used to predict possible plume migration. Conversely, concentration measurements for all types of contaminants in groundwater are a lagging indicator plume movement - major changes contaminant concentrations indicate that contamination has migrated. An approach based on measurement of master variables and explicit monitoring of hydrologic boundary conditions combined with traditional metrics should lead to improved monitoring while simultaneously reducing costs. This paradigm is being tested at the SRS F-Area where an innovative passive remedial system is being monitored and evaluated over the long term prior to traditional regulatory closure. Contaminants being addressed at this site are uranium, strontium-90, iodine-129, and tritium. We believe that the proposed strategies will be more effective in early identification of potential risks; these strategies will also be cost effective because controlling variables are relatively simple to measure. These variables also directly reflect the evolution of the plume through time, so that the monitoring strategy can be modified as the plume 'ages'. This transformational long-term monitoring paradigm will generate large cost savings to DOE, other federal agencies and industry and will provide improved performance and leading indicators of environmental management performance.

54 ENVIRONMENTAL SCIENCES↗