Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “computer simulations”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 847 records · Page 47

Destructive Error Interference in Product-Formula Lattice Simulation

Quantum computers can efficiently simulate the dynamics of quantum systems. Here, we study the cost of digitally simulating the dynamics of several physically relevant systems using the first-order product-formula algorithm. We show that the errors from different Trotterization steps in the algorithm can interfere destructively, yielding a much smaller error than previously estimated. In particular, we prove that the total error in simulating a nearest-neighbor interacting system of n sites for time t using the first-order product formula with r time slices is O ( n t / r + n t 3 / r 2 ) when n t 2 / r is less than a small constant. Given an error tolerance ϵ , the error bound yields an estimate of max { O ( n 2 t / ϵ ) , O ( n 2 t 3 / 2 / ϵ 1 / 2 ) } for the total gate count of the simulation. The estimate is tighter than previous bounds and matches the empirical performance observed in Childs et al. [ Proc. Natl. Acad. Sci. U.S.A. 115 , 9456 (2018) ]. We also provide numerical evidence for potential improvements and conjecture an even tighter estimate for the gate count.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Software-controlled, highly automated intrafraction prostate motion correction with intrafraction stereographic targeting: System description and clinical results

Purpose: A new system for software-controlled, highly automated correction of intrafraction prostate motion,'' intrafraction stereographic targeting'' (iSGT), is described and evaluated. Methods: At our institute, daily prostate positioning is routinely performed at the start of treatment beam using stereographic targeting (SGT). iSGT was implemented by extension of the SGT software to facilitate fast and accurate intrafraction motion corrections with minimal user interaction. iSGT entails megavoltage (MV) image acquisitions with the first segment of selected IMRT beams, automatic registration of implanted markers, followed by remote couch repositioning to correct for intrafraction motion above a predefined threshold, prior to delivery of the remaining segments. For a group of 120 patients, iSGT with corrections for two nearly lateral beams was evaluated in terms of workload and impact on effective intrafraction displacements in the sagittal plane. Results: SDs of systematic ({Sigma}) and random ({sigma}) displacements relative to the planning CT measured directly after initial SGT setup correction were <0.5 and <0.8 mm, respectively. Without iSGT corrections, effective {Sigma} and {sigma} for the 11-min treatments would increase to {Sigma}{sub eff} < 1.1 mm and {sigma}{sub eff} < 1.2 mm. With the iSGT procedure with an action level of 4 mm, effective positioning errors were reduced to {Sigma}{sub eff} < 0.8 mm and {sigma}{sub eff} < 1.0 mm, with 23.1% of all fractions requiring a correction. Computer simulations demonstrated that with an action level of 2 mm, the errors would have been reduced to {Sigma}{sub eff} < 0.6 mm and {sigma}{sub eff} < 0.7 mm, requiring corrections in 82.4% of the fractions. Because iSGT is highly automated, the extra time added by iSGT is <30 s if a correction is required. Conclusions: Without increasing imaging dose, iSGT successfully reduces intrafraction prostate motion with minimal workload and increase in fraction time. An action level of 2 mm is recommended.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

IMPACT SIMULATION AND THE SNS LINAC BEAM

Multi-particle tracking simulations for the SNS linac beam dynamics studies are performed with the IMPACT code. Beam measurement results are compared with the computer simulations, including beam longitudinal halo and beam losses in the superconducting linac, transverse beam Courant-Snyder parameters and the longitudinal beam emittance in the linac. In most cases, the simulations show good agreement with the measured results.

43 PARTICLE ACCELERATORS↗

IMPACT simulation and the SNS linac beam

Multi-particle tracking simulations for the SNS linac beam dynamics studies are performed with the IMPACT code. Beam measurement results are compared with the computer simulations, including beam longitudinal halo and beam losses in the superconducting linac, transverse beam Courant-Snyder parameters and the longitudinal beam emittance in the linac. In most cases, the simulations show good agreement with the measured results.

43 PARTICLE ACCELERATORS↗

Additive Technology in Optimal Synthesis of Individual Vehicle Components and Mechanisms

Experience in optimal synthesis of individual vehicle components and mechanisms on the basis of additive technology is analyzed. A list of basic additive technologies is presented. The benefits of additive technology in combination with three-dimensional computer simulation are noted. The possibility of visualizing CAE calculations by means of additive technology is considered. In addition, the role of additive technology in the manufacture of individual vehicle components and mechanisms is discussed.

42 ENGINEERING↗

Coordinating Garbage Collectionfor Arrays of Solid-State Drives

The primary goal of the extreme-scale plasma turbulence studies described in this article is to gain new insights on confinement scaling in magnetic fusion systems by using powerful, world-class supercomputers to carry out simulations with unprecedented resolution and temporal duration. New insights have been gained on the key question of how the turbulent transport of thermal energy and particles in the plasma and the associated confinement scale from present-generation devices to much larger ITER-size plasmas. In particular, new results from large-scale simulation studies have demonstrated that improvement in confinement as devices grow larger is far more gradual, with significantly lower loss rates than less-powerful computer simulations have indicated in research carried out over the past decade.

Computer Science↗

Segmented slant hole collimator for stationary cardiac SPECT: Monte Carlo simulations

Purpose: This work is a preliminary study of a stationary cardiac SPECT system. The goal of this research is to propose a stationary cardiac SPECT system using segmented slant-hole collimators and to perform computer simulations to test the feasibility. Compared to the rotational SPECT, a stationary system has a benefit of acquiring temporally consistent projections. The most challenging issue in building a stationary system is to provide sufficient projection view-angles. Methods: A GATE (GEANT4 application for tomographic emission) Monte Carlo model was developed to simulate a two-detector stationary cardiac SPECT that uses segmented slant-hole collimators. Each detector contains seven segmented slant-hole sections that slant to a common volume at the rotation center. Consequently, 14 view-angles over 180° were acquired without any gantry rotation. The NCAT phantom was used for data generation and a tailored maximum-likelihood expectation-maximization algorithm was used for image reconstruction. Effects of limited number of view-angles and data truncation were carefully evaluated in the paper. Results: Simulation results indicated that the proposed segmented slant-hole stationary cardiac SPECT system is able to acquire sufficient data for cardiac imaging without a loss of image quality, even when the uptakes in the liver and kidneys are high. Seven views are acquired simultaneously at each detector, leading to 5-fold sensitivity gain over the conventional dual-head system at the same total acquisition time, which in turn increases the signal-to-noise ratio by 19%. The segmented slant-hole SPECT system also showed a good performance in lesion detection. In our prototype system, a short hole-length was used to reduce the dead zone between neighboring collimator segments. The measured sensitivity gain is about 17-fold over the conventional dual-head system. Conclusions: The GATE Monte Carlo simulations confirm the feasibility of the proposed stationary cardiac SPECT system with segmented slant-hole collimators. The proposed collimator consists of combined parallel and slant holes, and the image on the detector is not reduced in size.

60 APPLIED LIFE SCIENCES↗

What Composition of High-Energy Physics Collaborations is Epistemically Optimal?

Computer simulations have recently come to the fore as a crucial tool for studying epistemic dynamics of scientific collectives. One pressing issue in big-ticket, long-term, and crowded particle physics research is the optimal organization of collaborations. This research developed a computation model of collaborations in high-energy physics and performed simulations to investigate the epistemic efficiency of groups and its dependence on the size of such groups and their composition: namely, percentages of pure, partially theoretically competent, and fully theoretically competent experimentalists. The present study reveals that in both small (100-member) and large (3000-member) groups, epistemic payoff as the measure of epistemic efficiency of collaborations is, generally, positively correlated with an increase in both the number of theoretically fully competent and pure (incompetent) experimentalists. Here, we are less certain of such conclusion in the case of the small collaborations. Although the subcommunity of experimentalists who are partially expert is not found to be immediately epistemically beneficial for collaborations, nevertheless they also crucially serve as a transitional community between the theorists and the experimentalists. Predicated on the toy model simulations, I suggest that institutions should provide measures to assist members of the latter subgroup in progressing toward developing a full theoretical expertise.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Computational Investigation of the Role of Active Site Heterogeneity for aSupported Organovanadium(III) Hydrogenation Catalyst

A crucial consideration for supported heterogeneous catalysts is the nonuniformity of the active sites, particularly for supported organometallic catalysts. Standard spectroscopic techniques, such as X-ray absorption spectroscopy, reflect the nature of the most populated sites, which are often intrinsically structurally distinct from the most active catalytic sites. Additionally, with computational models, often, only a few representative structures are used to depict catalytic active sites on a surface, even though there are numerous observable factors of surface heterogeneity that contribute to the kinetically favorable active species. A previously reported study on the mechanism of a surface organovanadium-(III) catalyst [(SiO 2 )V III (Mes)(THF)] for styrene hydrogenation yielded two possible mechanisms: heterolytic cleavage and redox cycling. These two mechanistic scenarios are challenging to differentiate experimentally since the kinetic readouts of the catalyst are identical. To showcase the importance of modeling surface heterogeneity and its effect on catalytic activity, density functional theory (DFT) computational models of a series of potential active sites of [(SiO 2 )V III (Mes)(THF)] for the reaction pathways are applied in combination with kinetic Monte Carlo (kMC) simulations. Computed results were then compared to the previously reported experimental kinetic study: (1) DFT free-energy reaction pathways indicated the likely active site and pathway for styrene hydrogenation, a heterolytic cleavage pathway requiring a bare tripodal vanadium site. (2) From the kMC simulations, a mixture of different bond lengths from the support oxygen to the metal center was required to qualitatively describe the experimentally observed kinetic aspects of a supported organovanadium(III) catalyst for olefin hydrogenation. This work underscores the importance of modeling surface heterogeneity in computational catalysis.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Tomographic Reconstruction of the Neutron Time-Energy Spectrum from a Dense Plasma Focus

A dense plasma focus (DPF) nuclear fusion device is an attractive pulsed neutron source in many applications, due to its relatively large neutron yield, produced in a short time duration. In order to design a DPF that generates neutrons within a specified time profile, or generates a neutron energy spectrum with specific properties, it is necessary to be able to characterize and model the results of the fusion process releasing the neutrons. The time-energy spectrum of fusion neutrons is an ideal quantity to use to validate multiphysics codes that simulate the pinch and fusion processes, because it is a quantity that requires the physics of each of the stages leading up to and ending in the fusion reaction to be simulated correctly. In particular, since DPF fusion neutrons are not monoenergetic -- and there can often be several fusion pinches creating neutrons -- a computer simulation matching high quality neutron spectrum measurements provides great confidence in the fidelity of the simulation. In order to make such a comparison, it is first necessary to have quality measurements from which to infer the spectrum. In this work we pose neutron spectroscopy as the classical tomographic inverse problem from neutron time of flight data at multiple distances, but enhanced by using an additional measurement of the time profile of the fusion pinch near its source and by using detector pairs set up in a geometry that allows for scatter background subtraction. The detector pairs enhance the quality of the time of flight measurements, and the additional constraint posed by the measured time profile allows for reconstructions discretized as finely as the time measurements and in energy as finely as 100 keV, without the problem being underdetermined. We present results from a Deuterium-fueled DPF at the U.S. Department of Energy's Nevada National Security Site and show that we can infer the time-energy spectrum from our measurements for both single and multi-pinch fusion reactions with equal fidelity.

Catenacci, Jared↗

Uniform attenuation correction using the frequency-distance principle

The frequency-distance principle (FDP) is a well-known relationship that relates the distance between the object and the detector to the slope in the two-dimensional Fourier transform of the projection sinogram. This relationship has been previously applied to compensation of the distance dependent collimator blurring in SPECT (single photon emission computed tomography) in the literature. This paper makes an attempt to use the FDP to correct for uniform attenuation in SPECT. Computer simulations reveal that this technique works well for objects consisting of point sources but does not work well for distributed objects.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Thermodynamics of grain-boundary phases

The past decade has seen a significant increase in research efforts aimed at understanding the thermodynamics of low-dimensional phases existing in many materials systems, ranging from two-dimensional materials to core regions of extended defects in crystalline solids. We review the current status of theoretical, computational, and experimental research on the “defect phases,” focusing on grain boundaries (GBs) in elemental and multicomponent polycrystalline materials. After reviewing the generalized concept of a phase of any dimensionality, we discuss recent progress in atomistic computer simulations of GB phase transformations and phase coexistences, including the observation of one-dimensional defects separating GB phases (defects in defects). Computational predictions compare well with experimental observations of multiple GB phases and segregation-induced phase transformations. An intriguing open question of GB thermodynamics is whether the GB free energy can be driven to a zero value by increasing solute segregation. We review recent efforts to understand this ultimate thermodynamic stabilization of GB phases and the possible polycrystalline microstructures that may arise. An outlook for future research in the field is discussed.

Materials science↗

Tomographic Reconstruction of the Neutron Time-Energy Spectrum from a Dense Plasma Focus

A dense plasma focus (DPF) nuclear fusion generator is an attractive pulsed neutron source in many applications, due to its relatively large neutron yield, produced in a short time duration. In order to design a DPF that generates neutrons within a specified time profile, or generates a neutron energy spectrum with specific properties, it is necessary to understand and be able to fully characterize the results of the fusion process releasing the neutrons. The time-energy spectrum of fusion neutrons is an ideal quantity to use to validate multiphysics codes that simulate the pinch and fusion processes, because it is a quantity that requires the physics of each of the stages leading up to and ending in the fusion reaction to be simulated correctly. In particular, since DPF fusion neutrons are not monoenergetic – and there can often be several fusion pinches creating neutrons – a computer simulation matching high quality neutron spectrum measurements provides great confidence in the fidelity of the simulation. In order to make such a comparison, it is first necessary to have quality measurements from which to infer the spectrum. In this work we pose neutron spectroscopy as the classical tomographic inverse problem from neutron time of flight data at multiple distances, but enhanced by using detector pairs designed to reduce the scatter background and with an additional measurement of the time profile of the fusion pinch near its source. The detector pairs enhance the quality of the time of flight measurements and the additional constraint posed by the measured time profile allows for temporal resolution in the spectrum reconstruction that is equal to the measurement resolution, which can be subnanosecond, and energy resolution in the 10’s of keV, without the problem being underconstrained. We present results from a Deuterium-fueled DPF at the U.S. Department of Energy’s Nevada National Security Site and show that we can infer the time-energy spectrum from our measurements for both single and multi-pinch fusion reactions with equal fidelity.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Velo: Riding the Knowledge Management Wave for Simulation and Modeling

Modern scientific enterprises are inherently knowledge-intensive. In general, scientific studies in domains such as geosciences, climate, and biology require the acquisition and manipulation of large amounts of experimental and field data in order to create inputs for large-scale computational simulations. The results of these simulations must then be analyzed, leading to refinements of inputs and models and further simulations. Further, these results must be managed and archived to provide justifications for publications and regulatory decisions that are based on these models. In this paper we describe our Velo framework that is designed as a reusable, domain independent knowledge management infrastructure for modeling and simulation. Velo leverages, integrates, and extends open source collaborative and content management technologies to create a scalable and flexible core platform that can be tailored to specific scientific domains. In this paper we describe the architecture of Velo for managing and associating the various types of data that are used and created in modeling and simulation projects, as well as the framework for integrating domain-specific tools. To demonstrate a realization of Velo, we describe the Geologic Sequestration Software Suite (GS3) that has been developed to support geologic sequestration modeling. This provides a concrete example of the inherent extensibility and utility of our approach.

99 GENERAL AND MISCELLANEOUS↗

Improving best-phase image quality in cardiac CT by motion correction with MAM optimization

Purpose: Research in image reconstruction for cardiac CT aims at using motion correction algorithms to improve the image quality of the coronary arteries. The key to those algorithms is motion estimation, which is currently based on 3-D/3-D registration to align the structures of interest in images acquired in multiple heart phases. The need for an extended scan data range covering several heart phases is critical in terms of radiation dose to the patient and limits the clinical potential of the method. Furthermore, literature reports only slight quality improvements of the motion corrected images when compared to the most quiet phase (best-phase) that was actually used for motion estimation. In this paper a motion estimation algorithm is proposed which does not require an extended scan range but works with a short scan data interval, and which markedly improves the best-phase image quality. Methods: Motion estimation is based on the definition of motion artifact metrics (MAM) to quantify motion artifacts in a 3-D reconstructed image volume. The authors use two different MAMs, entropy, and positivity. By adjusting the motion field parameters, the MAM of the resulting motion-compensated reconstruction is optimized using a gradient descent procedure. In this way motion artifacts are minimized. For a fast and practical implementation, only analytical methods are used for motion estimation and compensation. Both the MAM-optimization and a 3-D/3-D registration-based motion estimation algorithm were investigated by means of a computer-simulated vessel with a cardiac motion profile. Image quality was evaluated using normalized cross-correlation (NCC) with the ground truth template and root-mean-square deviation (RMSD). Four coronary CT angiography patient cases were reconstructed to evaluate the clinical performance of the proposed method. Results: For the MAM-approach, the best-phase image quality could be improved for all investigated heart phases, with a maximum improvement of the NCC value by 100% and of the RMSD value by 81%. The corresponding maximum improvements for the registration-based approach were 20% and 40%. In phases with very rapid motion the registration-based algorithm obtained better image quality, while the image quality of the MAM algorithm was superior in phases with less motion. The image quality improvement of the MAM optimization was visually confirmed for the different clinical cases. Conclusions: The proposed method allows a software-based best-phase image quality improvement in coronary CT angiography. A short scan data interval at the target heart phase is sufficient, no additional scan data in other cardiac phases are required. The algorithm is therefore directly applicable to any standard cardiac CT acquisition protocol.

60 APPLIED LIFE SCIENCES↗

RADIOGRAPHIC BENCHMARK PROBLEM 2009 - SCATTER CALCULATIONS IN MODELLING

Code Validation is a permanent concern in computer simulation, and has been addressed repeatedly in eddy current and ultrasonic modelling. A good benchmark problem is sufficiently simple to be taken into account by various codes without strong requirements on geometry representation capabilities, focuses on few or even a single aspect of the problem at hand to facilitate interpretation and to avoid that compound errors compensate themselves, yields a quantitative result and is experimentally accessible. In this paper we attempt to address code validation for one aspect of radio-graphic modelling, the scattered radiation prediction. An update of the results of the 2008 benchmark is presented. Additionally we discuss the extension of this benchmark on the lower energy part for 60 and 80 keV as well as for higher energies up to 10 MeV to study the contribution of pair production. Of special interest will be the primary radiation (attenuation law as reference), the total scattered radiation, the relative contribution of scattered radiation separated by order of scatter events (1st, 2nd, ..., 20th), and the spectrum of scattered radiation. We present the results of three Monte Carlo codes (MC-Ray, Sindbad and Moderato) as well as an analytical first order scattering code (VXI) and compare to MCNP as reference.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Plastic crystal phases of simple water models

We report the appearance of two plastic crystal phases of water at high pressure and temperature using computer simulations. In one of them the oxygen atoms form a body centered cubic structure (bcc) and in the other they form a face centered cubic structure (fcc). In both cases the water molecules were able to rotate almost freely. We have found that the bcc plastic crystal transformed into a fcc plastic crystal via a Martensitic phase transition when heated at constant pressure. We have performed the characterization and localization in the phase diagram of these plastic crystal phases for the SPC/E, TIP4P, and TIP4P/2005 water potential models. For TIP4P/2005 model free energy calculations were carried out for the bcc plastic crystal and fcc plastic crystal using a new method (which is a slight variation of the Einstein crystal method) proposed for these types of solid. The initial coexistence points for the SPC/E and TIP4P models were obtained using Hamiltonian Gibbs–Duhem integration. For all of these models these two plastic crystal phases appear in the high pressure and temperature region of the phase diagram. It would be of interest to study if such plastic crystal phases do indeed exist for real water. This would shed some light on the question of whether these models can describe satisfactorily the high pressure part of the phase diagram of water, and if not, where and why they fail.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗