Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “compositional noise”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 847 records · Page 47

Detectability of QCD phase transitions in binary neutron star mergers: Bayesian inference with the next generation gravitational wave detectors

We study the detectability of postmerger QCD phase transitions in neutron star binaries with next-generation gravitational-wave detectors Cosmic Explorer and Einstein Telescope. We perform numerical relativity simulations of neutron star mergers with equations of state that include a quark deconfinement phase transition through either a Gibbs or Maxwell construction. These are followed by Bayesian parameter estimation of the associated gravitational-wave signals using the nrpmw waveform model, with priors inferred from the analysis of the inspiral signal. We assess the ability of the model to measure the postmerger peak frequency $f$$^{peak}_{2}$ and identify aspects that should be improved in the model. We show that, even at postmerger signal to noise ratios as low as 10, the model can distinguish (at the 90% level) $f$$^{peak}_{2}$ between binaries with and without a phase transition in most cases. Phase-transition induced deviations in the $f$$^{peak}_{2}$ from the predictions of equation-of-state insensitive relations can also be detected if they exceed 1.6⁢σ. Our results suggest that next-generation gravitational wave detectors can measure phase transition effects in binary neutron star mergers. Furthermore, unless the phase transition is “strong,” disentangling it from other hadronic physics uncertainties will require significant theory improvements.

79 ASTRONOMY AND ASTROPHYSICS↗

Overcoming Variability: A Reproducible Approach to SERS Detection of Nanodiamonds

Detonation nanodiamonds (DNDs) are formed at specific pressures and temperatures during explosions. Different explosives produce varied yields of DNDs within their detonation soot, with Composition B producing the highest yield. Raman spectroscopy (RS) is often used for the characterization of sp 2 - and sp 3 -hybridized carbon allotropes in carbonaceous materials because of distinct disorder and graphitic bands. Bulk diamond also gives a distinct Raman peak at 1332 cm –1 . Furthermore, as bulk diamond decreases in size to nanometer-sized species, the peak red-shifts and broadens, becoming increasingly difficult to detect with RS using visible excitations. Therefore, surface-enhanced Raman spectroscopy (SERS) was used to enhance the diamond peak of DNDs, enabling better detection and faster examination of DNDs within detonation soot. Previous literature of the SERS of DNDs delivered inconsistent results in spectral signatures and SERS substrates. Herein, refining of the methodology for the acquisition of SERS spectra of DNDs was achieved. Before any SERS experiments, the DNDs were first characterized with normal Raman (NR) and scanning electron microscopy. Two routes for SERS enhancement were evaluated: colloidal noble metal nanoparticles and evaporated silver films. Silver films produced the best signal enhancement of DNDs with the best signal-to-noise and peak enhancements observed at 20–30 nm thick silver films at 5% (∼300 μW) laser power. Consistent, reproducible SERS spectra were acquired of small aggregates of DNDs down to ∼500 nm. NR and SERS mapping analysis of DNDs before and after evaporation of silver films revealed the improvements in the detection capabilities of SERS compared with NR.

Carbon↗

ASGRAD FY07 Annual Report

This is the annual project report for the ASGRAD project - Amorphous Semiconductors for Gamma Radiation Detection. We describe progress in the development of new materials for portable, room temperature, gammaradiation detection at Pacific Northwest National Laboratory. High Z, high resistivity, amorphous semiconductors are being designed for use as solid-state detectors at near ambient temperatures; their principles of operation are analogous to single-crystal semiconducting detectors. Compared to single crystals, amorphous semiconductors have the advantages of rapid, cost-effective, bulk-fabrication; nearnet-shape fabrication of complicated geometries; compositional flexibility; and greater electronic property control. The main disadvantage is reduced-charge carrier mobility. The focus of this project is to develop optimized amorphous semiconductor materials for gamma detection applications that leverage their material advantages while mitigating their limitations. During the second year of this project, several important milestones were accomplished. Major accomplishments were: (1) Significant processing - property and composition - property correlations were determined for Cd-Ge-As glasses; (2) Radiation response testing was successfully demonstrated on three different amorphous semiconductor materials (Cd-Ge-As, As-Se, and As-Se-Te systems) at ambient and near ambient temperatures; (3) Advanced, enabling Schottky contacts were developed for Cd-Ge-As compounds, this will allow these materials to perform at ambient temperatures; and (4) The collaborative working relationship developed with Prof. Angus Rockett at the University of Illinois at Urbana-Champaign (UIUC) has continued to grow, and they are credited with several of the materials characterization and contact development successes achieved this year. The development of Schottky barrier contacts in amorphous semiconductors by simply using different types of metal contacts is very significant. This is because these structures allow us to fabricate functional diodes using the Schottky barrier as the 'blocking' contact, similar to the familiar silicon surface barrier detector. In device terms, lower resistivity materials with better charge carrier mobility properties can be used and operated under reverse bias to create a low-noise, high-resistivity condition that can be switched to a low-resistivity, high conductivity condition under exposure to radiation events, and then off again. In the future, lithographic techniques could be used to create an array of FET's, and thereby build pixilated detectors that would have 2D position-sensitive radiation detection capability. Thus, the third year of the project will be dedicated to building diode-based devices from these amorphous semiconductors. The major challenges to date with the Schottky contacts have been a large variation in device behavior from contact to contact, and the relative fragility of the contacts. We are developing strategies to solve these issues. Additionally, particular emphasis will be directed towards characterizing device performance in response to ionizing radiation, which is key to demonstrating the viability of amorphous semiconductor-based detectors.

36 MATERIALS SCIENCE↗

Physical and Structural Studies on the Cryo-cooling of Insulin Crystals

Reflection profiles were analyzed from microgravity-(mg) and earth-grown insulin crystals to measure mosaicity (h) and to reveal mosaic domain structure and composition. The effects of cryocooling on single and multi-domain crystals were compared. The effects of cryocooling on insulin structure were also re-examined. Microgravity crystals were larger, more homogeneous, and more perfect than earth crystals. Several mg crystals contained primarily a single mosaic domain with havg of 0.005deg. The earth crystals varied in quality and all contained multiple domains with havg of 0.031deg. Cryocooling caused a 43-fold increase in h for mg crystals (havg=0.217deg) and an %fold increase for earth crystals (havg=0.246deg). These results indicate that very well-ordered crystals are not completely protected from the stresses associated with cryocooling, especially when structural perturbations occur. However, there were differences in the reflection profiles. For multi-mosaic domain crystals, each domain individually broadened and separated from the other domains upon cryo-cooling. Cryo-cooling did not cause an increase in the number of domains. A crystal composed of a single domain retained this domain structure and the reflection profiles simply broadened. Therefore, an improved signal-to-noise ratio for each reflection was measured from cryo-cooled single domain crystals relative to cryo-cooled multi-domain crystals. This improved signal, along with the increase in crystal size, facilitated the measurement of the weaker high- resolution reflections. The observed broadening of reflection profiles indicates increased variation in unit cell dimensions which may be linked to cryo-cooling-associated structural changes and disorder.

Lovelace, J.↗

Strain-Gauge Measurement of Weight of Fluid in a Tank

A method of determining the amount of fluid in a tank is based on measurement of strains induced in tank supports by the weight of the fluid. Unlike most prior methods, this method is nonintrusive: there is no need to insert instrumentation in the tank and, hence, no need to run wires, cables, or tubes through the tank wall. Also unlike most prior methods, this method is applicable even if the fluid in the tank is at supercritical pressure and temperature, because it does not depend on the presence of a liquid/gas interface (as in liquid-level-measuring methods). The strain gauges used in this method are of two types: foil and fiber-optic. Four foil gauges and one or more fiber-optic gauges are mounted on each of the tank-supporting legs. An additional fiber-optic gauge is mounted on an object, made of the same material as that of the tank-supporting legs, that is not subjected to any mechanical load. The reading obtained by the additional fiber-optic gauge is used to compensate for apparent strains caused by changes in temperature. The signals from the foil and fiber-optic gauges are conditioned, then digitized for input to a computer. As the tank is filled or emptied, the deformation in each leg increases or decreases, respectively. Measured deformations of all legs are added to obtain a composite deformation indicative of the change in weight of the tank plus fluid. An initial calibration is performed by recording data at two points (usually, empty and full) for which the mass or weight of fluid is known. It is assumed that the deformations are elastic, so that the line passing through the two points can be used as a calibration curve of mass (or weight) of fluid versus deformation. At the time of reporting the information for this article, a set of foil gauges had been tested on the supports of a 500-gallon (1,900-liter) tank. The gauges were found to be capable of measuring the deformations (up to 22 microstrain) that occurred during filling and emptying the tank. The fluid masses calculated from the gauge readings were found to be accurate within 4.5 percent. It has been estimated that once the fiber-optic gauges are put into operation, it should be possible to determine fluid masses with 3 percent or less. It may be possible to increase accuracy further by increasing the signal-to-noise ratio through the use of more deformable tank supporting legs.

Figueroa, Jorge↗

Plastic neutron detectors.

This work demonstrated the feasibility and limitations of semiconducting {pi}-conjugated organic polymers for fast neutron detection via n-p elastic scattering. Charge collection in conjugated polymers in the family of substituted poly(p-phenylene vinylene)s (PPV) was evaluated using band-edge laser and proton beam ionization. These semiconducting materials can have high H/C ratio, wide bandgap, high resistivity and high dielectric strength, allowing high field operation with low leakage current and capacitance noise. The materials can also be solution cast, allowing possible low-cost radiation detector fabrication and scale-up. However, improvements in charge collection efficiency are necessary in order to achieve single particle detection with a reasonable sensitivity. The work examined processing variables, additives and environmental effects. Proton beam exposure was used to verify particle sensitivity and radiation hardness to a total exposure of approximately 1 MRAD. Conductivity exhibited sensitivity to temperature and humidity. The effects of molecular ordering were investigated in stretched films, and FTIR was used to quantify the order in films using the Hermans orientation function. The photoconductive response approximately doubled for stretch-aligned films with the stretch direction parallel to the electric field direction, when compared to as-cast films. The response was decreased when the stretch direction was orthogonal to the electric field. Stretch-aligned films also exhibited a significant sensitivity to the polarization of the laser excitation, whereas drop-cast films showed none, indicating improved mobility along the backbone, but poor {pi}-overlap in the orthogonal direction. Drop-cast composites of PPV with substituted fullerenes showed approximately a two order of magnitude increase in photoresponse, nearly independent of nanoparticle concentration. Interestingly, stretch-aligned composite films showed a substantial decrease in photoresponse with increasing stretch ratio. Other additives examined, including small molecules and cosolvents, did not cause any significant increase in photoresponse. Finally, we discovered an inverse-geometric particle track effect wherein increased track lengths created by tilting the detector off normal incidence resulted in decreased signal collection. This is interpreted as a trap-filling effect, leading to increased carrier mobility along the particle track direction. Estimated collection efficiency along the track direction was near 20 electrons/micron of track length, sufficient for particle counting in 50 micron thick films.

36 MATERIALS SCIENCE↗

Effect of Resonator Axis Skew on Normal Incidence Impedance

High by-pass turbofan engines have fewer fan blades and lower rotation speeds than their predecessors. Consequently, the noise suppression at the low frequency end of the noise spectra has become an increasing concern. This has led to a renewed emphasis on improving noise suppression efficiency of passive, duct liner treatments at the lower frequencies. For a variety of reasons, passive liners are comprised of locally-reacting, resonant absorbers. One reason for this design choice is to satisfy operational and economic requirements. The simplest liner design consists of a single layer of honeycomb core sandwiched between a porous facesheet and an impervious backing plate. These resonant absorbing structures are integrated into the nacelle wall and are very ef- ficient over a limited bandwidth centered on their resonance frequency. Increased noise suppression bandwidth and greater suppression at lower frequencies is typically achieved for conventional liners by increasing the liner depth and incorporating thin porous septa into the honeycomb core. However, constraints on liner depth in modern high by-pass engine nacelles severely limit the suppression bandwidth extension to lower frequencies. Also, current honeycomb core liners may not be suitable for irregular geometric volumes heretofore not considered. It is of interest, therefore, to find ways to circumvent liner depth restrictions and resonator cavity shape constraints. One way to increase effective liner depth is to skew the honeycomb core axis relative to the porous facesheet surface. Other possibilities are to alter resonator cavity shape, e.g. high aspect ratio, narrow channels that possibly include right angle bends, 180. channel fold-backs, and splayed channel walls to conform to irregular geometric constraints. These possibilities constitute the practical motivation for expanding impedance modeling capability to include unconventional resonator orientations and shapes. The work reported in this paper is in the nature of a progress report and is limited to examining the implications of resonator axis skew on the composite normal incidence impedance of an array of resonator channels. Specifically, experimental results are compared with a modified impedance prediction model for highaspect- ratio, rectangular, resonator channels with varying amounts of skew relative to the incident particle velocity. It is shown that for resonator channel widths of 1 to 2 mm, aspect ratios of 25 to 50, and skew angles of zero to sixty degrees, the surface impedance of test models can be predicted with good accuracy. Predicted resistances and reactances are particularly well correlated through the first resonance and first anti-resonance for all six test models investigated. Beyond the first anti-resonance, the impedance prediction model loses the ability to predict details of resistance and reactance but still predicts the mean trends very well.

Parrott, Tony L.↗

Solid state NMR method development and studies of biological and biomimetic nanocomposites

This thesis describes application and development of advanced solid-state nuclear magnetic resonance techniques for complex materials, in particular organic-inorganic nanocomposites and thermoelectric tellurides. The apatite-collagen interface, essential for understanding the biomineralization process in bone and engineering the interface for controlled bio-mimetic synthesis and optimized mechanical properties, is buried within the nanocomposite of bone. We used multinuclear solid-state NMR to study the composition and structure of the interface. Citrate has been identified as the main organic molecule strongly bound to the apatite surface with a density of 1/(2 nm) 2 , covering 1/6 of the total surface area in bovine bone. Citrate provides more carboxylate groups, one of the key functional groups found to affect apatite nucleation and growth, than all the non-collagenous proteins all together in bone; thus we propose that citrate stabilizes apatite crystals at a very small thickness of ~3 nm (4 unit cells) to increase bone fracture tolerance. The hypothesis has been confirmed in vitro by adding citrate in the bio-mimetic synthesis of polymerhydroxyapatite nanocomposites. The results have shown that the size of hydroxyapatite nanocrystals decreases as increasing citrate concentration. With citrate concentrations comparable to that in body fluids, similar-sized nanocrystals as in bone have been produced. Besides the dimensions of the apatite crystals, the composition of bone also affects its biofunctional and macroscopic mechanical properties; therefore, our team also extended its effort to enhance the inorganic portion in our bio-mimetic synthesis from originally 15 wt% to current 50 wt% compared to 65 wt% in bovine bone, by using Lysine-Leucine hydroxyapatite nucleating diblock co-polypeptide, which forms a gel at very low concentration. In this thesis, various advanced solid state NMR techniques have been employed to characterize nanocomposites. Meanwhile, we have developed new methods to achieve broadband high resolution NMR and improve the accuracy of inter-nuclear distance measurements involving quadrupolar spins. Broadband high resolution NMR of spin-1/2 nuclei has been accomplished by the adaptation of the magic angle turning (MAT) method to fast magic angle spinning, termed fast MAT, by solving technical problems such as off resonance effects. Fast MAT separates chemical shift anisotropy and isotropic chemical shifts over a spectral range of ~1.8 γB 1 without significant distortions. Fast MAT 125 Te NMR has been applied to study technologically important telluride materials with spectra spreading up to 190 kHz. The signal-to-noise ratio of the spectra is significantly improved by using echo-matched Gaussian filtering in offline data processing. The accuracy of the measured distances between spin-1/2 and quadrupolar nuclei with methods such as SPIDER and REAPDOR has been improved by compensating for the fast longitudinal quadrupolar relaxation on the sub-millisecond with a modified S 0 pulse sequence. Also, the T1Q effect on the spin coherence and its spinning speed dependency has been explored and documented with analytical and numerical simulations as well as experimental measurements.

36 MATERIALS SCIENCE↗

Exploring the Potential of Residual Impurities in Germanium Detectors for MeV-Scale Dark Matter Detection

Abstract The direct detection of MeV-scale dark matter (DM) particles hinges on achieving an exceptionally low-energy detection threshold. Germanium (Ge) detectors, meticulously tailored with precise impurity compositions, hold the potential to enhance sensitivity to energy levels below the sub-electronvolt (sub-eV) range. This study explores the behavior of residual impurities inherent to Ge detectors at helium temperatures, unveiling a captivating freeze-out phenomenon leading to the formation of excited localized states known as dipole states. Using compelling evidence from relative capacitance measurements obtained from two detectors, we elucidate the transition of impurity atoms from free charge states to these dipole states as the temperature drops from 11 to 6.5 K. Our investigation comprehensively covers the intricate formation of these dipole states in bothn-type andp-type impurities. Furthermore, we shed light on the electric field generated by these dipole states, revealing their ability to trap charges and facilitate the creation of cluster dipole states. Confirming findings from previous measurements, we establish that these excited dipole states exhibit a binding energy of less than 10 meV, offering an exceptionally low detection threshold for MeV-scale DM. Building upon this concept, we propose the development of a 1-kg Ge detector with internal charge amplification—an innovative approach poised to surpass electrical noise and enable the detection of MeV-scale DM with unprecedented sensitivity.

Physics↗

Development and validation of a supervised machine learning radar Doppler spectra peak-finding algorithm

In many types of clouds, multiple hydrometeor populations can be present at the same time and height. Studying the evolution of these different hydrometeors in a time–height perspective can give valuable information on cloud particle composition and microphysical growth processes. However, as a prerequisite, the number of different hydrometeor types in a certain cloud volume needs to be quantified. This can be accomplished using cloud radar Doppler velocity spectra from profiling cloud radars if the different hydrometeor types have sufficiently different terminal fall velocities to produce individual Doppler spectrum peaks. Here we present a newly developed supervised machine learning radar Doppler spectra peak-finding algorithm (named PEAKO). In this approach, three adjustable parameters (spectrum smoothing span, prominence threshold, and minimum peak width at half-height) are varied to obtain the set of parameters which yields the best agreement of user-classified and machine-marked peaks. The algorithm was developed for Ka-band ARM zenith-pointing radar (KAZR) observations obtained in thick snowfall systems during the Atmospheric Radiation Measurement Program (ARM) mobile facility AMF2 deployment at Hyytiälä, Finland, during the Biogenic Aerosols – Effects on Clouds and Climate (BAECC) field campaign. The performance of PEAKO is evaluated by comparing its results to existing Doppler peak-finding algorithms. The new algorithm consistently identifies Doppler spectra peaks and outperforms other algorithms by reducing noise and increasing temporal and height consistency in detected features. In the future, the PEAKO algorithm will be adapted to other cloud radars and other types of clouds consisting of multiple hydrometeors in the same cloud volume.

54 ENVIRONMENTAL SCIENCES↗

Alumina+Silica+/-Germanium Alteration in Smectite-Bearing Marathon Valley, Endeavour Crater Rim, Mars

Mars Exploration Rover Opportunity has been exploring Mars for 12+ years, and is presently investigating the geology of a western rim segment of 22 kilometers diameter, Noachian- aged Endeavour crater. The Alpha Particle X-ray Spectrometer has determined the compositions of a pre-impact lithology, the Matijevic fm., and polymict impact breccias ejected from the crater, the Shoemaker fm. Opportunity is now investigating a region named Marathon Valley that cuts southwest-northeast through the central portion of the rim segment and provides a window into the lower stratigraphic record. (Geographic names used here are informal.) At the head of Marathon Valley, referred to here as Upper Marathon Valley, is a shallow, ovoid depression approximately 25×35 millimeters in size, named Spirit of Saint Louis. Layering inside Spirit of Saint Louis appears continuous with the Upper Marathon Valley rocks outside, indicating they are coeval. Spirit of Saint Louis is partly bounded by approximately 10-20 centimeters wide zone containing reddish altered rocks (red zone). Red zones also form prominent curvilinear features in Marathon Valley. Compact Reconnaissance Imaging Spectrometer for Mars (CRISM) spectra provide evidence for a really extensive Fe-Mg smectite in the Marathon Valley region, indicating distinct styles of aqueous alteration. The CRISM detections of smectites are based on metal-OH absorptions at approximately 2.3 and 2.4 micron that are at least two times the background noise level.

Mittlefehldt, D. W.↗

A Hyperspectral Inversion Framework for Estimating Absorbing Inherent Optical Properties and Biogeochemical Parameters in Inland and Coastal Waters

The simultaneous remote estimation of biogeochemical parameters (BPs) and inherent optical properties (IOPs) from hyperspectral satellite imagery of globally distributed optically distinct inland and coastal waters is a complex, unsolved, non-unique inverse problem. To tackle this problem, we leverage a machine-learning model termed Mixture Density Networks (MDNs). MDNs outperform operational algorithms by calculating the covariance between the simultaneously estimated products. We train the MDNs on a large ( N = 8237) dataset of co-aligned, in situ measured, hyperspectral remote sensing reflectance (R rs ), BPs, and absorbing IOPs from globally representative optically distinct inland and coastal waters. The estimated IOPs include absorption due to phytoplankton (a ph ), chromophoric dissolved organic matter (a cdom ), and non-algal particles (a nap ). The estimated BPs include chlorophyll-a, total suspended solids, and phycocyanin (PC). MDNs dramatically reduce uncertainty in the retrievals, relative to operational algorithms, when using a 50/50 dataset split, where the MDNs are trained on a randomly selected half of the in situ dataset and validated on the other half. Our model is shown to have higher, or equivalent, generalization performance than the calculated operational algorithms available for all BPs and IOPs (except PC) via a leave-one-out cross-validation assessment. The MDNs are sensitive to uncertainties in the hyperspectral satellite R rs , resulting from instrument noise and atmospheric correction; there is a difference of ~37.4–62.8% (using median symmetric accuracy) between the MDNs’ estimates derived from co-located satellite-derived R rs and in situ R rs . Of the IOPs, a cdom and a nap are less sensitive to uncertainties in hyperspectral satellite imagery relative to a ph , with remote estimates of a ph exhibiting incorrect spectral shape and magnitude relative to in situ measured IOPs. Despite the uncertainties in satellite derived R rs , the spatial distributions of BPs and IOPs in MDN-derived product maps of Lake Erie and the Curonian Lagoon, based on imagery taken with the Hyperspectral Imager for the Coastal Ocean (HICO) and PRecursore Iper-Spettrale della Missione Applicativa (PRISMA), are confirmed via co-aligned in situ measurements and agree with the literature’s understanding of these well-studied regions. The consistency and accuracy of the model on HICO and PRISMA imagery, despite radiometric uncertainties, demonstrate its applicability to future hyperspectral missions, such as the Plankton, Aerosol, Cloud, ocean Ecosystem (PACE) mission, where the simultaneous estimation model will serve as a key part of phytoplankton community composition analysis.

Ryan E. O'Shea↗

Elevated Temperature Alpha Spectroscopy with Nickel-Platinum {sup 4}H-SiC Schottky Diodes

In order to protect against the diversion of special nuclear material during pyro-processing of spent nuclear fuel, an online monitoring of the actinide concentrations must be developed. In order to do so, alpha spectroscopy can be employed in order to determine the relative concentrations of various isotopes based on the characteristic alpha spectrum of each isotope of interest. The operating temperatures in the pyro-processing environment are such that high temperature operability of alpha detectors is required. The Idaho National Laboratory (INL) electro-refiner operates at a molten salt temperature of approximately 500 deg. C. The vapor temperature above the molten salt is approximately 100 deg. C. In order to provide reasonably compact online monitoring of the actinide concentrations within the molten salt the detector would be located in this vapor region. The temperature in this location is too high for a commercial silicon detector to operate without serious signal degradation due to thermal noise. As the operating temperature increases, the thermal energy available to the charge carriers within the semiconductor increases. For narrow band-gap semiconductors like silicon, this increase in free charge carriers with increasing temperature leads to unacceptable leakage current at relatively low temperatures when compared with wide band-gap materials. In order to overcome this, a wide band-gap material is employed. An alpha particle sensor utilizing a nickel Schottky barrier {sup 4}HSiC wafer was heated to a temperature of 100 deg. C and an alpha spectrum collected. The performance of the sensor at 100 deg. C was compared to the room temperature performance. Molten salts such as those used in the INL electro-refiner exhibit strong corrosive properties. Any sensor which will be exposed to or submerged in the molten salt must have a ruggedized sensor face capable to withstand the corrosive environment. In the contact design utilized in this paper the Schottky barrier forming metal, nickel, is coated with a thin layer of platinum to serve as a corrosion resistant layer. An additional modification to previous designs was the simplification of the Schottky barrier composition. A Schottky barrier is created when a metal is brought into close physical contact with a semiconductor. To first order, the barrier height of the Schottky barrier is a result of the mismatch between the electron affinity of the semiconductor and the metal work function of the metal. In previous iterations, the high temperature performance of the detectors had been limited by diffusion processes between the various metal layers. In order to reduce the likelihood of such a degradation, the Schottky contact structure was simplified without loss of functionality. By replacing the multiple metal layers with a nickel Schottky forming layer capped with a thin platinum layer, the potential degradation of the Schottky barrier height could be reduced, primarily through the similar Schottky barrier height to nickel formed by platinum with SiC.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Chemical Sensor Development and Antibacterial Activities Based on Polyaniline/Gemini Surfactants for Environmental Safety

The polyaniline doped novel anionic gemini surfactant (PANI/GS) was chemically synthesized by a micellar polymerization process and then characterized in details by X-ray powder diffractometry, scanning electron microscopy, and FTIR spectroscopy. The results show the presence of polyaniline in the emeraldine base was formed by doping with gemini surfactant. The thermal properties of the composites were studied by carrying out thermal gravimetric analysis. The PANI/GS were found to be soluble in common organic solvents such as chloroform as well as DMSO. The antibacterial activity of the obtained PANI/GS was also evaluated against Gram positive bacteria Bacillus subtilis, Gram negative bacteria Escherichia coli and antibiotics (Amoxicillin) using the agar plate. The antibacterial study showed that the PANI/GS was found to be most effective against both B. subtilis and E. coli respectively which was significant compared to the amoxicillin. Beside that thin-layer of PANI/GS onto glassy carbon electrode (GCE) was fabricated with conducting 5% nafion coating agents to fabricate a sensitive and selective Cd{sup 2+} ionsic sensor in short response time into the phosphate buffer phase. The fabricated cationic-sensor was exhibited higher sensitivity, large-dynamic concentration ranges, long-term stability, and improved electrochemical performances towards Cd{sup 2+} ions. The calibration plot is linear (r{sup 2}, 0.9799) over the large Cd{sup 2+} concentration ranges (10.0 nM–1.0 mM). The sensitivity and detection limit is calculated as 2.324 µA µM{sup −1}cm{sup −2} and 6.85 nM (signal-to-noise ratio, at a SNR of 3) respectively. These novel efforts are intiated a well-known method for significant cationic sensor development with directly fabricated nanocomposite onto GCE for the detection of hazardous toxins in ecological and environmental fields in huge scales. Graphical Abstract: .

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Diffusion-assisted selective dynamical recoupling: A new approach to measure background gradients in magnetic resonance

Dynamical decoupling, a generalization of the original NMR spin-echo sequence, is becoming increasingly relevant as a tool for reducing decoherence in quantum systems. Such sequences apply non-equidistant refocusing pulses for optimizing the coupling between systems, and environmental fluctuations characterized by a given noise spectrum. One such sequence, dubbed Selective Dynamical Recoupling (SDR) [P. E. S. Smith, G. Bensky, G. A. Álvarez, G. Kurizki, and L. Frydman, Proc. Natl. Acad. Sci. 109, 5958 (2012)], allows one to coherently reintroduce diffusion decoherence effects driven by fluctuations arising from restricted molecular diffusion [G. A. Álvarez, N. Shemesh, and L. Frydman, Phys. Rev. Lett. 111, 080404 (2013)]. The fully-refocused, constant-time, and constant-number-of-pulses nature of SDR also allows one to filter out “intrinsic” T{sub 1} and T{sub 2} weightings, as well as pulse errors acting as additional sources of decoherence. This article explores such features when the fluctuations are now driven by unrestricted molecular diffusion. In particular, we show that diffusion-driven SDR can be exploited to investigate the decoherence arising from the frequency fluctuations imposed by internal gradients. As a result, SDR presents a unique way of probing and characterizing these internal magnetic fields, given an a priori known free diffusion coefficient. This has important implications in studies of structured systems, including porous media and live tissues, where the internal gradients may serve as fingerprints for the system's composition or structure. The principles of this method, along with full analytical solutions for the unrestricted diffusion-driven modulation of the SDR signal, are presented. The potential of this approach is demonstrated with the generation of a novel source of MRI contrast, based on the background gradients active in an ex vivo mouse brain. Additional features and limitations of this new method are discussed.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Experimental investigation of cathode spots and plasma jets behavior subjected to two kinds of axial magnetic field electrodes

In this paper, cathode spot plasma jet (CSPJ) rotation and cathode spots behavior subjected to two kinds of large diameter axial magnetic field (AMF) electrode (cup-shaped and coil-shaped) are studied and analyzed based on experiments. The influence of gap distances on the CSPJ rotational behavior is analyzed. Experimental results show that CSPJ rotational phenomena extensively exist in the vacuum interrupters, and CSPJ rotational direction is along the direction of composite magnetic field (mainly the combination of the axial and azimuthal components). For coil-shaped and cup-shaped AMF electrodes, the rotational or inclination phenomena before the current peak value are much more significant than that after current peak value (for the same arc current), which is related to the larger ratio of azimuthal magnetic field B{sub t} and AMF B{sub z} (B{sub t}/B{sub z}). With the increase of the gap distance, the AMF strength decreases, when the arc current is kept as constant, the azimuthal magnetic field is kept invariable, the ratio between azimuthal magnetic field and AMF is increased, which results in the increase of rotational effect. For cathode spots motion, compared with cup-shaped electrode, coil-shaped electrode has the inverse AMF direction. The Robson drift direction of cathode spots of coil-shaped electrode is opposite to that of cup-shaped electrode. With the increase of gap distance, the Robson angle is decreased, which is associated with the reduced AMF strength. Erosion imprints of anode and cathode are also related to the CSPJ rotational phenomena and cathode spots behavior. The noise of arc voltage in the initial arcing stage is related to the weaker AMF.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

CONSTRAINTS ON THE FORMATION OF THE GALACTIC BULGE FROM Na, Al, AND HEAVY-ELEMENT ABUNDANCES IN PLAUT's FIELD

We report chemical abundances of Na, Al, Zr, La, Nd, and Eu for 39 red giant branch (RGB) stars and 23 potential inner disk red clump stars located in Plaut's low-extinction window. We also measure lithium for a super Li-rich RGB star. The abundances were determined by spectrum synthesis of high-resolution (R Almost-Equal-To 25,000), high signal-to-noise (S/N {approx} 50-100 pixel{sup -1}) spectra obtained with the Blanco 4 m telescope and Hydra multifiber spectrograph. For the bulge RGB stars, we find a general increase in the [Na/Fe] and [Na/Al] ratios with increasing metallicity, and a similar decrease in [La/Fe] and [Nd/Fe]. Additionally, the [Al/Fe] and [Eu/Fe] abundance trends almost identically follow those of the {alpha}-elements, and the [Zr/Fe] ratios exhibit relatively little change with [Fe/H]. The consistently low [La/Eu] ratios of the RGB stars indicate that at least a majority of bulge stars formed rapidly ({approx}<1 Gyr) and before the main s-process could become a significant pollution source. In contrast, we find that the potential inner disk clump stars exhibit abundance patterns more similar to those of the thin and thick disks. Comparisons between the abundance trends at different bulge locations suggest that the inner and outer bulges formed on similar timescales. However, we find evidence of some abundance differences between the most metal-poor and metal-rich stars in various bulge fields. The data also indicate that the halo may have had a more significant impact on the outer bulge initial composition than the inner bulge composition. The [Na/Fe], and to a lesser extent [La/Fe], abundances further indicate that the metal-poor bulge, at least at {approx}1 kpc from the Galactic center, and thick disk may not share an identical chemistry.

79 ASTRONOMY AND ASTROPHYSICS↗

NOx Sensor Development

NO{sub x} compounds, specifically NO and NO{sub 2}, are pollutants and potent greenhouse gases. Compact and inexpensive NO{sub x} sensors are necessary in the next generation of diesel (CIDI) automobiles to meet government emission requirements and enable the more rapid introduction of more efficient, higher fuel economy CIDI vehicles. Because the need for a NO{sub x} sensor is recent and the performance requirements are extremely challenging, most are still in the development phase. Currently, there is only one type of NO{sub x} sensor that is sold commercially, and it seems unlikely to meet more stringent future emission requirements. Automotive exhaust sensor development has focused on solid-state electrochemical technology, which has proven to be robust for in-situ operation in harsh, high-temperature environments (e.g., the oxygen stoichiometric sensor). Solid-state sensors typically rely on yttria-stabilized zirconia (YSZ) as the oxygen-ion conducting electrolyte and then target different types of metal or metal-oxide electrodes to optimize the response. Electrochemical sensors can be operated in different modes, including amperometric (a current is measured) and potentiometric (a voltage is measured), both of which employ direct current (dc) measurements. Amperometric operation is costly due to the electronics necessary to measure the small sensor signal (nanoampere current at ppm NO{sub x} levels), and cannot be easily improved to meet the future technical performance requirements. Potentiometric operation has not demonstrated enough promise in meeting long-term stability requirements, where the voltage signal drift is thought to be due to aging effects associated with electrically driven changes, both morphological and compositional, in the sensor. Our approach involves impedancemetric operation, which uses alternating current (ac) measurements at a specified frequency. The approach is described in detail in previous reports and several publications. Briefly, impedancemetric operation has shown the potential to overcome the drawbacks of other approaches, including higher sensitivity towards NO{sub x}, better long-term stability, potential for subtracting out background interferences, total NO{sub x} measurement, and lower cost materials and operation. Past LLNL research and development efforts have focused on characterizing different sensor materials and understanding complex sensing mechanisms. Continued effort has led to improved prototypes with better performance, including increased sensitivity (to less than 5 ppm) and long-term stability, with more appropriate designs for mass fabrication, including incorporation of an alumina substrate with an imbedded heater. Efforts in the last year to further improve sensor robustness have led to successful engine dynamometer testing with prototypes mounted directly in the engine manifold. Previous attempts had required exhaust gases to be routed into a separate furnace for testing due to mechanical failure of the sensor from engine vibrations. A more extensive cross-sensitivity study was also undertaken this last year to examine major noise factors including fluctuations in water, oxygen, and temperature. The quantitative data were then used to develop a strategy using numerical algorithms to improve sensor accuracy. The ultimate goal is the transfer of this technology to a supplier for commercialization. Due to the recent economic downturn, suppliers are demanding more comprehensive data and increased performance analysis before committing their resources to take the technology to market. Therefore, our NO{sub x} sensor work requires a level of technology development more thorough and extensive than ever before. The objectives are: (1) Develop an inexpensive, rapid-response, high-sensitivity and selective electrochemical sensor for oxides of nitrogen (NO{sub x}) for compression-ignition, direct-injection (CIDI) exhaust gas monitoring; (2) Explore and characterize novel, effective sensing methodologies based on impedance measurements and designs and manufacturing methods that could be compatible with mass fabrication; and (3) Collaborate with industry in order to (ultimately) transfer the technology to a supplier for commercialization.

36 MATERIALS SCIENCE↗