Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “circuitry”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 847 records · Page 47

Electrochemical studies in aluminum chloride melts

A melt purification system was developed which produces a final melt far superior electrochemically than those previously reported. A residual current of less than 2 microamps/sq mn at a sweep rate of 0.5 V/sec was used as the criteria for a pure melt. The use of a second purified bulk melt and a heated pipette permitted the rapid exchange of working electrode compartments while retaining the same reference electrode system. The major portion of the work was carried out in the 1:1 AlCl3:NaCl melt at 175 and 200 C. Several measurements were made in the 2:1 melt and a few on the silver systems in intermediate compositions. Programs for PDP-8I and PDP-12 digital computers and the required electronic circuitry systems were developed to carry out various electrochemical measurements in the melt. A pair of 50 yard transmission lines were used to connect the computer to the experiment. Ensemble averaging and digital, least squares smoothing are used within the programs to improve the signal-to-noise ratio by at least an order of magnitude. Some of the computerized electrochemcial techniques used to examine the different systems were pulse polarography, double pulse polarography, staircase voltammetry, kinetic double potential step chronoamperometry and double potential step chronocoulometry.

Osteryoung, R. A.↗

Uses of ceramics in microelectronics: A survey

The properties and behavior of ceramic materials used in components for electronic circuitry are examined to appraise the present and future directions for microelectronics, and to suggest further product development, and how innovations may be useful in other technologies. Ceramic and glass insulators, resistors, capacitors, and the use of ceramics and glasses in microcircuitry are discussed along with technology transfer to nonaerospace uses.

Bratschun, W. R.↗

Development of a wideband wattmeter as a laboratory instrument

A portable, solid state, wideband wattmeter has been developed as a general purpose type of laboratory instrument. Its circuit and component investigations and evaluation data are presented. A prototype unit was used extensively, and served as the basis for a second instrument incorporating refined circuitry and improved packaging. The wattmeter provides true four quadrant operation which permits instantaneous indication of real power as an oscilloscope display. Major performance factors are: frequency bandwidth DC to 1 MHz plus or minus 1 db; current range 10 mA to 100 amperes peak; voltage range 1 volt to 1000 volts peak; accuracy plus or minus 2% of full scale reading. Oscilloscope data for typical switching transients in a transistor inverter circuit are included.

Landes, L. G.↗

Design of a three-phase, 15-kilovolt-ampere static inverter for motor-starting a Brayton space power system

The design of a three-phase, 400-Hz, 15-kVA static inverter for motor-starting the 2- to 15-kWe Brayton electrical space power system is described. The inverter operates from a nominal 56-V dc source to provide a 28-V, rms, quasi-square-wave output. The inverter is capable of supplying a 200-A peak current. Integrated circuitry is used to generate the three-phase, 400-Hz reference signals. Performance data for a drive stage that improves switching speed and provides efficient operation over a range of output current and drive supply voltage are presented. A transformerless, transistor output stage is used.

Frye, R. J.↗

A 100,000 pulse height analyzer for use in High Energy Cosmic Ray Experiments (HECRE) on high altitude balloon flights

A description is given of a wide dynamic range pulse height analyzer system developed for use on High Energy Cosmic Ray Experiment (HECRE) Balloon Flights. A wide dynamic range of 100,000 is obtained by extending the range of a basic 1024 channel analyzer through the use of multiple ranges and range selection. The system described here contains four 100,000 pulse height analyzers. Each 100,000 pulse height analyzer consists of a group of cordwood welded modules mounted and interconnected on a printed circuit card. Four of these card assemblies, the required clock drive circuitry (discrete components mounted and interconnected on a separate card) and three input-output connectors are interconnected and mounted on the system board.

Cancro, C. A.↗

Design, development, fabrication and delivery of register and multiplexer units

Two complementary MOS monolithic chip types were developed, which contain a register and multiplexer unit to be used in the central processing unit of a digital computer. The partition of the logic into a chip size consistent with the characteristics of the packages is discussed. The logic was implemented by specially configured circuitry designed to layout, as well as to optimize, performance by taking advantage of the properties of CMOS logic. Of several approaches considered for generating LSI CMOS arrays, the CMOS standard cell array design technique was selected. These design automation techniques were used to generate the chip layout, art work and working master plates, followed by the fabrication and testing of the two chip types. Sixty functional LSI arrays were delivered.

Feller, A.↗

Design, fabrication and testing of two electrohydraulic vibration isolation systems for helicopter environments

Two electrohydraulic vibration isolation systems were designed and fabricated to reduce the vertical vibrations transmitted to the XH-51N research helicopter cabin at the blade passage frequency (18 Hz) and its first harmonic (36 Hz). Hydraulic power and electrical control are provided to two separate servoactuators from a common power supply and control electronics package located behind the pilot's seat. One servoactuator is installed between the cabin and fuselage and replaces an existing passive spring. A second servoactuator is mounted between the existing seat and cabin floor. Both servoactuators incorporate a mechanical failsafe design. The control electronics circuitry provides automatic tracking of the blade passage frequency. Results of laboratory, environmental and ground vibration tests employing an XH-51A stripped down helicopter fuselage show that the active cabin isolator reduces the vertical vibrations transmitted from the fuselage attachment point to the cabin attachment point at 18 and 36 Hz (or as an alternative, 6 Hz) by better than 90 percent.

Allen, R. E.↗

Development of nondestructive testing techniques for plated-through holes in multilayer printed circuit boards

The development of a nondestructive test with the capability to interrogate plated-through holes as small as 0.51 millimeters inside diameter is discussed. The system can detect defects such as holes, voids, cracks, and thin spots that reduce the current carrying capability of plates-through interconnects by 20 percent or more. Efforts were directed toward the design and fabrication of magnetic circuitry mutual coupling probes and to evaluate the effectiveness of these devices for detecting in multilayer board plated-through holes.

Anthony, P. L.↗

Cold cathode gage experiment (lunar-atmosphere detector)

A preliminary evaluation of the cold cathode gage experiment which was included in the ALSEP to determine the amount of gas present on the lunar surface is reported. The instrument, electronic circuitry, and deployment are described. The preliminary results are summarized and include temperature history, and variations in gas concentration detected after deployment.

Johnson, F. S.↗

Operational testing of system for automatic sleep analysis

Tables on the performance, under operational conditions, of an automatic sleep monitoring system are presented. Data are recorded from patients who were undergoing heart and great vessel surgery. This study resulted in cap, electrode, and preamplifier improvements. Children were used to test the sleep analyzer and medical console write out units. From these data, an automatic voltage control circuit for the analyzer was developed. A special circuitry for obviating the possibility of incorrect sleep staging due to the presence of a movement artifact was also developed as a result of the study.

Kellaway, P.↗

Long-life, space-maintainable nuclear stage regulators and shutoff valves

The six most promising valve, regulator, and remote coupling concepts, representing the more radical designs from twenty concepts generated, were investigated. Of the three valves, one has no moving parts because shutoff sealing is accomplished by an electromagnetic field which ionized the flowing fluid. Another valve uses liquid metal to obtain sealing. In the third valve, high sealing forces are generated by heating and expanding trapped hydrogen. The pressure regulator is an electronically controlled, electromechanically operated, single state valve. Its complexity is in electronic circuitry, and the design results in less weight, increased reliability and performance flexibility, and multipurpose application. The two remote couplings feature the minimization of weight and mechanical complexity. One concept uses a low melting temperature metal alloy which is injected into the joint cavity; upon solidification, the alloy provides a seal and a structural joint. The second concept is based on the differential thermal expansion of the coupling mating parts. At thermal equilibrium there is a predetermined interference between the parts, and sealing is achieved by interference loading.

Source record↗

Modification of a fuel-cell engine for control by a digital computer

A manually operated fuel-cell system was modified to be monitored and controlled by a digital computer. The purpose was to have a test item with which to study possible system-computer interface problems. The modification consisted of installing solenoid valves, circuitry, transducers, and limit switches on the system. These modifications permit computer control of load current, reactant purge, water removal, and electrolyte concentration and computer initiation of system shutdown.

Hagedorn, N. H.↗

Solid state ku-band power amplifier

The design, fabrication, and testing of two types of IMPATT diode reflection amplifiers and a transmission amplifier are given. The Ku-band IMPATT diode development is discussed. Circuitry and electrical performance of the final version of the Ku-band amplifier is described. Construction details and an outline and mounting drawing are presented.

Bowers, H. C.↗

Hybrid circuit modules for motor commutation and control

Thick film hybrid techniques are used to develop circuitry for a brushless dc motor commutator. The power commutator contains the driving circuit and an amplifier that controls the armature current. A position decoder contains digital integrated circuits which receive the signals from the armature position sensors and generate the driving signals for the power commutator in the proper sequence. These units drive motors with stall currents up to about 400 mA.

Dekramer, C.↗

The NAS-PAK Logic System

The design and fabrication of telemetry ground data processing equipment using commercial logic cards or modules are discussed. A microelectronics program was initiated to evaluate circuitry, packaging methods, and fabrication approaches necessary to produce a competitively procured logic system. The NAS-PAK logic system covering all phases of implementation is considered.

Billingsley, J.↗

Digital canopus tracker digital electronics

Circuitry has been developed for digital control of the Canopus tracker. A feasibility and demonstration breadboard has been constructed using microelectronic integrated circuits. The breadboard contains the digital circuits necessary for closed-digital logic necessary for star acquisition, particle rejection, programmable gate selection, cone angle selection, and routing of the digital roll error signal.

Crawford, W. E.↗

Research program for experiment M133

The development of the automatic data-acquisition and sleep-analysis system is reported. The purpose was consultation and evaluation in the transition of the Skylab M133 Sleep-Monitoring Experiment equipment from prototype of flight status; review of problems associated with acquisition and on-line display of data in near-real time via spacecraft telemetry; and development of laboratory facilities and design of equipment to assure reliable playback and analysis of analog data. The existing prototype system modified, and the changes improve the performance of the analysis circuitry and increase its reliability. These modifications are useful for pre- and postflight analysis, but are not now proposed for the inflight system. There were improvements in the EEG recording cap, some of which will be incorporated into the flight hardware.

Frost, J. D., Jr.↗

Magnetic field effects on superconductivity in alkali metal intercalates of MoS2

The effects of a magnetic field on the superconducting transition in MoS2 intercalated with potassium and sodium were studied. It was found that the potassium intercalated MoS2 has better properties in a magnetic field. In zero magnetic field the transition to superconductivity begins near 6.4 K. Diagrams of the basic circuitry for superconducting transition studies, and charts showing critical magnetic field versus critical temperature for the intercalated MoS2 are included.

Woollam, J. A.↗