Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “capacity test”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 847 records · Page 47

Experimental Evaluation of Thermal Storage Performance of a Dual-Purpose Underground Thermal Battery

A geothermal heat pump (GHP) system is an energy-efficient building heating and cooling technology with great potential for reducing energy consumption and decarbonization. However, applications of GHP are still limited due to the high cost, of which 30% is related to the cost of installing the conventional vertical bore ground heat exchangers, which are usually installed in boreholes 60 meters deep. A dual-purpose underground thermal battery (DPUTB) has been developed to offer a low-cost ground heat exchanger with a built-in thermal storage capacity. The DPUTB innovatively integrates a shallow-bore ground heat exchanger (the outer tank), which can be installed in a borehole less than 6 m deep, with thermal energy storage (TES) (the inner tank). DPUTB has the potential to reduce the cost of a ground source heat pump system while allowing shifting the electric demand of the building served by the GHP system from peak to off-peak hours of the electric grid by charging and discharging the thermal storage. A lab-scale (1:125 in volume) DPUTB prototype was built. Phase change material (PCM) was added to increase the thermal storage capacity and maintain the supply water temperature from the TES within the desired range for direct cooling operation during the discharge period. As PCMs are critical to the TES performance of the DPUTB, this study compared the influence of different PCMs (including salt hydrate and organic PCMs) on the discharge performance of the DPUTB. The thermal State of Charge (SoC) of the DPUTB was used to compare the performance resulting from using different PCMs. Test results indicate that the organic PCM (Methyl Laurate) outperforms salt-hydrate PCMs due to a lower melting temperature and a narrower melting temperature range during the phase change process. The results of this study provide a guide for PCM selection and the optimal design of DPUTB.

Wang, Lingshi↗

Optimizing Heat Recovery with Storage: Control Validation and Sensitivity Analysis of the Time-Independent Energy Recovery Plant Using Modelica

Heat recovery in large building central plants saves energy but traditionally requires simultaneous heating and cooling. The Time-Independent Energy Recovery (TIER) plant shifts this paradigm by integrating thermal energy storage (TES) to enable heat recovery regardless of concurrent demand, offering a highly efficient, space-saving solution to achieve California’s energy goals. However, its integration of heat recovery chillers, cooling-only chillers, cooling towers, and trim air-source heat pumps (ASHPs) creates growing control and sizing complexity. To overcome this, this study employs high-fidelity Modelica dynamic simulation to validate TIER control sequences and optimize equipment sizing. We translated the written Sequences of Operation into executable Control Description Language (CDL) to test logic against sub-hourly loads. This verification workflow successfully identified and resolved critical vulnerabilities, such as thermal storage freezing and equipment short-cycling, in a virtual environment prior to physical deployment. Then, the study analyzes TIER plant performance across three simulated building types in three locations, and a real building load profile, ensuring variety in heating and cooling loads, and simultaneity factors and explores sizing rules for the TES and ASHP capacity. The analysis shows that the TIER plant operates equipment efficiently leading to a plant SCOP of around 7.5 across all scenarios, higher than a traditional ASHP plant, and a viable pathway to de-risk complex system design and control through simulation to identify optimal designs that maximize energy efficiency, minimize operational costs, and ensure robust operation in varied environmental conditions, thereby facilitating the broader adoption of such a solution for large buildings.

Zanetti, Ettore↗

A Study of Model-Based Protective Fast-Charging and Associated Degradation in Commercial Smartphone Cells: Insights on Cathode Degradation as a Result of Lithium Depositions on the Anode

The ever expanding mobile consumer electronic market has accelerated the need for safe and efficient fast-charging approaches that improve the overall speed of battery charging without hastened deterioration of the battery performance. Herein, the impact of a resource inexpensive, physics-based, electrochemically optimized fast-charging algorithm (charging time < 2 h) for mobile devices is investigated. A critical difference in the amount and morphology of lithium deposits on the anode for cells fast-charged without an optimized algorithm is observed and found to be the main cause of capacity decay. Furthermore, an in-depth study of the LiCoO 2 cathode regions opposite to pronounced lithium deposits on the anode reveals a “mirroring” phenomenon, i.e., a frozen monoclinic phase, and inactivity to relithiation. In operando hard X-ray absorption spectroscopy reveals that degraded spots on harvested cathodes seem to be activated again and participate in the intercalation process when lithiated at low rates from lithium foil counter electrodes. On the other hand, tests at higher C-rates, closer to the actual fast-charging rate, reveal only negligible oxidation state changes and therefore poor performance.

25 ENERGY STORAGE↗

Sustainable recovery of critical metals from spent lithium-ion batteries through gluconic acid-based bioleaching: Techno-economic analysis, life cycle assessment and process optimization

Recycling spent lithium-ion batteries (LIB) could potentially bridge the ever increasing supply and demand gap for critical metals and simultaneously facilitate the management of hazardous battery waste. This study investigated the optimization of gluconic acid-based bioleaching technology through design of experiments (DOE), combined with techno-economic analysis (TEA), and life cycle assessment (LCA) with the aim of maximizing the net present value (NPV) and minimizing global warming impacts of the process. Biolixiviant containing predominantly gluconic acid produced by the genetically engineered (ΔpstS, P 112 :mgdh) Gluconobacter oxydans B58 through fermentation using non-recyclable paper as a growth substrate was used for the LIB leaching. At optimal bioleaching conditions of gluconic acid (160 mM), leaching time (2.5 h), reducing agent FeSO 4 to metal, i.e., cobalt (Co), nickel (Ni) and manganese (Mn), mole ratio (0.88), temperature (55 °C) and pulp density (2.5 %), the leaching efficiency was 87 % 72 %, 94 %, and 88 % for Co, Ni, Mn and lithium (Li), respectively. TEA analysis confirmed that bioleaching plant with an annual black mass processing capacity of 10,000 metric tons and plant life of 30 years would be economically viable with an NPV and profit margin of $136 million and 11 %, respectively. The predicted carbon footprint of gluconic acid-based bioleaching for recovering 1 kg of Co (13.2 kg of CO 2 eq.) is lower compared to that of most state-of-the-art leaching technologies. Moreover, gluconic acid-based bioleaching effectively recovered target metals when tested for different black mass chemistries.

Bioleaching↗

Oxygen-deficient ammonium vanadate for flexible aqueous zinc batteries with high energy density and rate capability at -30 °C

Aqueous zinc batteries (AZBs) have received significant attention owing to environmental friendliness, high energy density and inherent safety. However, lack of high-performance cathodes has become the main bottleneck of AZBs development. Here, oxygen-deficient NH 4 V 4 O 10–x ·nH 2 O (NVOH) microspheres are synthesized and used as cathodes for AZBs. The experimental test and theoretical calculations demonstrate that the oxygen vacancies in the lattice lower the Zn 2+ diffusion energy barrier, which enables fast Zn 2+ diffusion and good electrochemical performance in a wide temperature range. The suppressed side reactions also can help to improve the low temperature performance. NVOH shows a high energy density of 372.4 Wh kg –1 and 296 Wh kg –1 at room temperature and –30 °C, respectively. Moreover, NVOH maintains a 100% capacity retention after 100 cycles at 0.1 A g –1 and ~94% capacity retention after 2600 cycles at 2 A g –1 and –30 °C. Investigation into the mechanism of the process reveals that the capacity contribution of surface capacitive behaviors is dominant and capacity attenuation is mainly caused by the decay of diffusion-controlled capacity. As a result, flexible AZBs can steadily power portable electronics under different bending states, demonstrating its great potential in wide-temperature wearable device.

25 ENERGY STORAGE↗

Late day measurement of excised branches results in uncertainty in the estimation of two stomatal parameters derived from response curves in Populus deltoides Bartr. x Populus nigra L.

Many terrestrial biosphere models depend on an understanding of the relationship between stomatal conductance and photosynthesis. However, unlike the measurement of photosynthetic parameters, such as the maximum carboxylation capacity, where standard methods (e.g., CO 2 response or ACi curves) are widely accepted, a consensus method for empirically measuring parameters representing stomatal response has not yet emerged. Most models of stomatal response to environment represent stomatal conductance as being bounded by a lower intercept parameter (g 0 ), and linearly scaled based on a multivariate term described by the stomatal slope parameter (g 1 ). Here we employ the widely used Unified Stomatal Optimization model, to test whether g 1 and g 0 parameters are impacted by the choice of measurement method, either on an intact branch, or a cut branch segment stored in water. We measured paired stomatal response curves on intact and excised branches of a hybrid poplar clone (Populus deltoides Bartr. x Populus nigra L. OP367), measured twice over a diurnal period. We found that predawn branch excision did not significantly affect measured g 0 and g 1 when measured within 4 h of excision. Measurement in the afternoon resulted in significantly higher values of g 1 and lower values of g0, with values changing by 55% and 56% respectively. Excision combined with afternoon measurement resulted in a marked effect on parameter estimates, with g1 increasing 89% from morning to afternoon and a 25% lower g 1 for cut branches than those measured in situ. We also show that in hybrid poplar the differences in parameter estimates obtained from plants measured under different conditions can directly impact models of canopy function, reducing modeled transpiration by 18% over a simulated 12.5-hour period. While these findings are only for a single isohydric woody species, our findings suggest that stomatal optimality parameters may not remain constant throughout the day.

54 ENVIRONMENTAL SCIENCES↗

High Performance Solvent for NGCC Flue Gas CO 2 Capture (Final Technical Report)

Amine-based solvent absorption is the most mature and reliable technology for large scale CO 2 capture, dating back to the 1930s when monoethanolamine (MEA) was used to treat acid gases from oil refineries. However, while strategic advancements have optimized the CO2 capture process, the cost of capture remains high, where current estimates suggest that CO 2 capture costs are around $\$$72/tonne of CO 2 . To address this, solvent development and optimization have become a focus of current research. This project sought to develop a high-performance solvent to reduce the overall cost of CO 2 capture from NGCC flue gas. Here, solvent optimization focused on: (1) reducing the energy required for CO 2 desorption in a reboiler, (2) improving CO 2 absorption and desorption reaction kinetics, (3) improving solvent stability, and (4) reducing environmental impacts. Susteon has developed and evaluated a promoted solvent, Sustenol™, for NGCC flue gas CO 2 capture. The optimized Sustenol™ also shows a higher dynamic CO 2 absorption capacity of ~0.5 mol CO2 /mol amine compared to 0.25 mol CO2 /mol amine for 30 wt% MEA. Additionally, the solvent is oxidatively, thermally and hydrothermally stable, which leads to lower solvent loss and emissions. These advancements have resulted in a solvent regeneration energy of 2.16 GJ/tonne of CO 2 which is >30% lower than current state-of-the-art commercial and emerging solvents. Combined with empirical data from the bench and pilot scale testing, this preliminary TEA study indicated the cost of CO 2 capture by Sustenol™ for 97% CO 2 removal at $\$$54/tonne and for 90% removal at $\$$49/tonne, with a pathway to achieve $\$$45/tonne of CO 2 with continued process and solvent advancements. Susteon has developed a technology roadmap to reduce the cost of CO 2 capture to <$\$$45/tonne for NGCC flue gas. Susteon plans to derisk this technology for commercial deployment through comprehensive solvent degradation testing, long-term testing in a pilot plant at 5 tonne CO2 /day and demonstration scale testing at 100 tonne CO2 /day with NGCC flue gas and engineering design studies to qualify Sustenol™ as a drop-in replacement solvent.

03 NATURAL GAS↗

An experimental study on gas-liquid phase fluid migration in hydrate-bearing sediments during hydrate dissociation

Natural gas hydrate production tests face problems such as severe sand blockage, poor gas-liquid phase separation, and significant land subsidence. This is because of the insufficient understanding of the complex phase transition and gas-liquid multi-phase fluid migration during hydrate dissociation. In hydrate-bearing sediment systems, hydrate phase transition couples with gas-liquid fluid migration. The phase transition causes changes in pore structure, which in turn modifies porous infiltration parameters and fluid flow capacity. Meanwhile, alterations in phase interfaces affect key parameters like surface tension and wettability. Gas-liquid fluid migration influences heat and mass transfer, thus affecting phase equilibrium and dissociation rates. To bridge the gap in describing gas-liquid fluid migration during hydrate dissociation in experiments, this research innovatively integrated an unsteady-state gas displacement by water and a quantitative hydrate dissociation process, independently developed a multi-phase seepage experimental system suitable for hydrate dissociation and determined the relationship between seepage parameters and hydrate saturation under different porosity. The results are as follows: a) Core samples with higher initial porosity show a greater recovery rate of fluid flow capacity. b) The retarding effect of multi-phase fluid has a more significant impact on the migration of the wetting phase fluid (water) than that of the non-wetting phase fluid (methane). c) During hydrate dissociation, the evolution of absolute permeability shows an “S-shaped” pattern, and the evolution of relative permeability shows a “wiring-harness” pattern. In conclusion, the findings can provide a theoretical basis for preventing geological disasters and for geotechnical engineering design during hydrate production.

58 GEOSCIENCES↗

A Novel Zwitterionic Chromatography Approach to Separate Lithium from Unconventional Resources

Lithium (Li) is a key element for clean energy technologies, and, accordingly, the global lithium demand has been increasing rapidly. Therefore, to meet the Li demand and maintain supply chain stability, it is critical to develop efficient lithium extraction technologies that allow exploitation of unconventional lithium resources, such as geothermal brines and inland brine streams. However, the recovery of Li from these resources is challenging due to low Li concentration, low ratios of Li/Na, Li/Mg, or Li/Ca, and complex feed compositions. To address this, we introduced a new Direct Lithium Extraction (DLE) process using Zwitterionic Chromatography (ZIC) to separate Li from other salts. Since salts are partitioned on ZIC under water elution, no reagent chemicals are needed, and the Li separation is not limited by the adsorption capacity. We prepared 13 different zwitterionic (ZI) resins to investigate the salt retention on various ZI groups and then screened out promising sorbents for efficient Li separation. It was found that salt retention was synergistically affected by the pore size and ZI configurations. Using carboxybetaine (QAC3CA) sorbents, multicomponent separations showed that Li can be partitioned from divalent salts or Na with selectivities of 1.8 or 1.9, respectively. Although the selectivity is relatively low, in real brine tests, Li was separated from Ca and Mg with 79.2 % yield, showing the potential for a continuous process to achieve high productivity and high yield. Simulation studies suggest the salt elution mechanism is related to the hydration reaction energy and the effective hydrated radius of cations.

critical minerals↗

Coupled machine learning–ecosystem ensemble models substantially improve predictions of nitrous oxide (N 2 O) fluxes from US croplands

Nitrous oxide (N 2 O) is a potent and persistent greenhouse gas, with rising atmospheric concentrations driven in part by inefficient use of synthetic nitrogen (N) fertilizers in agriculture. Predicting soil N 2 O emissions is challenging due to high spatial and temporal variability arising from complex soil biogeochemical processes. Process-based ecosystem models and standalone machine learning (ML) approaches without extensive site-specific calibration often miss high-emission episodes. Here, we show how an Ensemble Modeling System (EMS) based on outputs from an ensemble of ecosystem models coupled to an ensemble of ML models can improve predictions and understanding of N 2 O fluxes from US cropland. Trained and validated on ~12,000 N 2 O chamber measurements at 17 US Midwest sites (six crops, 35 management practices), the EMS accurately predicted daily fluxes of N 2 O at both training (R 2 = 0.84, RMSE = 16.4 g N ha −1 d −1 ) and held-out testing sites (R 2 = 0.84, RMSE = 6.2 g N ha −1 d −1 ). Analyses identified six dominant N 2 O drivers: soil organic carbon (SOC), NH 4 + , NO 3 - , water-filled pore space, temperature, and aboveground biomass production. Wet, warm soils produced large N 2 O peaks only with sufficient SOC and mineral N; in low-SOC soils, fluxes remained low. Incorporating these drivers into process-based models might significantly improve their predictive capacity. The EMS demonstrates a strong potential to predict N 2 O fluxes at unseen sites, enabling more reliable regional inventories, improved gap-filling where measurements are sparse, and enhanced understanding of mechanisms to advance targeted mitigation strategies in food, feed, and bioenergy crops.

AI↗

Design of a Single-Ion Conducting Polymer Electrolyte for Sodium-Ion Batteries

Here, a sodium bis(fluoroallyl)malonato borate salt (NaBFMB) is synthesized. Using a Click thiol-ene reaction, NaBFMB can be photo-crosslinked with a tri-thiol (trimethylolpropane tris(3-mercapto propionate), TMPT) to create a single-ion conducting electrolyte (NaSIE), with all negative charges residing on the borate moieties and anions immobilized through the 3-D crosslinked network. The NaSIE can be prepared either as a free-standing film or through a drop-cast method followed by a photo crosslinking method for an in-situ formation on top of the electrodes. The free-standing film of NaSIE has a high ionic conductivity of 2 × 10 –3 S cm –1 at 30 °C, and a high transference number (t Na + ) of 0.91 as measured through the Bruce-Vincent method. The electrochemical stability of NaSIE polymer electrolyte is demonstrated via cyclic voltammetry (CV) to be stable up to 5 V vs Na/Na + . When tested inside a symmetrical Na//Na cell, the NaSIE shows a critical current density (CCD) of 0.4 mA cm –2 . The stability of NaSIE is further demonstrated via a long cycling of the stripping/plating test with a current density of 0.1 mA cm –2 at five-minute intervals for over 10,000 min. Using the in-situ method, NaSIE is used as the electrolyte for a sodium metal battery using P2 (Na resides at prismatic sites with with ABBAAB stacking)-cathode of Na 0.67 Ni 0.33 Mn 0.67 O 2 (NNMO) and is cycled between the cut-off voltages of 2.0–4.0 V. A high initial specific capacity (85.7 mAh g –1 ) with a capacity retention of 86.79% after 150 cycles is obtained.

25 ENERGY STORAGE↗

Performance Assessment of a Dual-purpose HP-TES for a Typical Year Comparing Different Climate Zones

Complete electrification of heating and cooling systems in the United States would overload the existing electrical grid. To this end, recent research efforts have focused on energy storage as one way to reduce ever-increasing peak electricity demands. One such technology is heat pump integrated thermal-energy storage (HP-TES) systems, which can enable load-shifting and reduce demand during peak hours. In this work, a Modelica model of a 4-Ton, dual-mode (heating and cooling) HP-TES system using a room-temperature phase-change material (PCM) integrated through a secondary hydronic loop was developed and simulated for a typical meteorological year in Riverside, CA (ASHRAE Climate Zone 2B), and Chicago, IL (ASHRAE Climate Zone 5A), for a DOE small office prototype building. The COP improvement and demand reduction were analyzed during the time-of-use peak hours along with the required recharge cycle energy demand. A typical summer in Riverside, CA resulted in model-predicted peak COP increases of 50 – 100% compared to the baseline heat pump, especially at higher outdoor temperatures, coupled with maximum peak energy reductions of 22%. During shoulder and winter season simulations, heating energy savings were higher as outdoor temperatures dropped below the PCM phase change temperature. For Chicago, IL, backup heating was necessary to meet the required system capacity for very cold ambient conditions, resulting in winter peak energy savings between 16 – 60% when accounting for backup heating requirements. The recharge energy was found to be mostly below the baseline HP energy during the peak. With improved component selections and controls, the recharge energy may be reduced. The outcomes from the simulations can provide first-order estimates for potential peak energy savings, challenges, and required controls in any location before conducting any field testing.

25 ENERGY STORAGE↗

In Situ Synthesis of Phosphate-Based CelloMOF as a Promising Separator for Li–Ion Batteries

Nowadays, battery separators play a critical role in determining the sustainability, electrochemical efficiency, and safety of lithium-ion batteries (LIBs). In this contribution, we developed fire-resistant composite membranes called CelloMOF by in situ grafting of metal-organic framework, ZIF-67, onto phosphorylated cellulose nanofibers (P-CNFs) followed by a vacuum filtration process akin to papermaking. The hybrid ZIF-67@P-CNF membrane exhibits superior properties than a polyolefin-based commercial separator (CS) in terms of enhanced thermal and dimensional stability, flame-retardant properties, better surface wettability, and improved electrolyte uptake. Thermal dimensional stability tests revealed that the ZIF-67@P-CNF separator maintained its structure even at 200 °C, whereas CS suffered severe shrinkage, potentially leading to internal short circuits. Combustion tests showed a peak heat release rate (PHRR) of 34.5 W/g and a total heat release (THR) of 1.61 kJ/g for ZIF-67@P-CNF, significantly lower than the PHRR (1111.82 W/g) and THR (40.89 kJ/g) of CS. The composite separator also demonstrated significantly improved wettability, with a contact angle of 32 ± 1.04°, compared to 92 ± 1.07° for CS, highlighting its hydrophilic nature. Electrochemical evaluations in LiFePO 4 /Li half-cells indicated a higher discharge capacity of 149 mA h g -1 at 0.2 C and superior capacity retention of 86% after 50 cycles, outperforming CS (145 mA h g -1 and 84%, respectively). In conclusion, these results underscore the potential of the ZIF-67@P-CNF membrane to advance safe, high-performance LIBs by addressing critical challenges in thermal stability, flame retardancy, and electrolyte compatibility.

ZIF-67↗

Impact of Hydrogen on Methane and Pollutant Emissions over Three-Way Catalysts with Natural Gas–Hydrogen Blends

Blending natural gas (NG) with hydrogen (H₂) can improve combustion and engine performance while potentially facilitating the catalytic conversion of methane and other pollutants, resulting in cleaner tailpipe emissions. This study evaluates the impact of H2 on the conversion of methane, CO, and NOx emissions on a commercial three-way catalyst (TWC) in a flow reactor using synthetic gas mixtures that simulate stoichiometric engine exhausts with NG or NG+H₂ combustion. The work examines whether, and how, the additional amount of H₂ in the exhaust stream affects the conversion efficiency of methane and other pollutants. Experiments were conducted with both degreened and aged catalysts under controlled conditions, systematically varying temperature, the air-to-fuel equivalence ratio (λ), and λ modulation. Test conditions covered λ values from 0.996 to 1.000 to represent nominally stoichiometric engine operation with different λ modulation amplitudes, as well as a range of temperatures to inform control strategies for effective CH₄, CO, and NOₓ reduction. Overall, the results show that hydrogen addition significantly improves the conversion efficiency of CH₄ and NOₓ, particularly at temperatures below 500 °C. More significantly, this study highlights that exhaust gas composition, operating temperature, λ management, and the oxygen storage capacity of the TWC all play major roles in affecting the tailpipe emissions from NG and NG+H₂ combustion.

Prikhodko, Vitaly [ORNL] (ORCID:0000000244685836)↗

Mechanical response and microstructure evolution from multiaxial stress relaxation in textured zircaloy nuclear cladding

Modern energy markets provide motivation for nuclear reactors to increase operational flexibility and load following capacity of existing reactor designs. The operational power changes result in fuel pellet expansion and contraction resulting in pellet-cladding mechanical interaction (PCMI) and high cladding stresses that are strongly related to stressed corrosion cracking (SCC) which can lead to fuel rod failure. This work aims to quantify the stress fields in cladding with a focus on multiaxial stress relaxation response from an imposed strain and the resulting microstructure changes in textured zircaloy claddings. Stress relaxation tests resulting in multiaxial stress fields are performed to measure the material response of Zircaloy-4 nuclear cladding. Multiple experiments using samples from the same piece of cladding are performed so samples with the same processing history may be removed at strategic points throughout mechanical testing for microstructure characterization. The microstructure evolution is analyzed with mechanical response to evaluate the static recovery impact on crystallographic texture and grain morphology. Experiments are performed at Idaho National Laboratory using an experimental device capable of applying internal pressure and independent axial load to commercial nuclear cladding at elevated temperatures with stress- or strain-controlled experimental capability. X-ray diffraction and electron backscatter diffraction are used for microstructure analysis. Rheological models are used to visualize the multiaxial stress-strain relationships and isolate elastic, plastic, and viscoplastic material properties for analysis.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Probabilistic Sizing of Energy Storage Systems for Reliability and Frequency Security in Wind-Rich Power Grids

The penetration of wind energy has increased significantly in the power grid in recent times. Although wind is abundant, environment-friendly, and cheap, it is variable in nature and does not contribute to system inertia as much as conventional synchronous generators. Coupled with the low inertia contribution, the generation intermittency of wind power leads to reliability and stability issues in the power system. Energy storage systems (ESSs) are among the most prominent alternatives to alleviate these concerns associated with high wind penetration. This paper proposes a planning strategy to size ESS for the reliability and frequency security of wind-rich power grids. A probabilistic methodology for ESS sizing is developed utilizing a composite reliability-based framework with sequential Monte Carlo simulation (MCS). The MCS generates composite reliability indices for the power system, which are employed to obtain the capacity for a reliability energy storage system (RESS). Simultaneously, the MCS-derived probability of synchronization of conventional generators is integrated into an analytical approach for sizing a frequency support energy storage system (FESS). The effect of wind farm dispersion across geographical regions is incorporated in the framework to study possible reductions in the ESS size while maintaining the system reliability and frequency security. Furthermore, the efficacy of the proposed strategy is demonstrated on the RTS-GMLC test system.

25 ENERGY STORAGE↗

Chapter 2: Evaluating a Concentrating Solar Power Plantas an Extended-Duration Peaking Resource

We explore the ability of a concentrating solar power (CSP) plant with thermal energy storage (TES) to provide peaking capacity. We focus on future power systems, wherein net load patterns may be significantly different than they are today (e.g., due to higher renewable-energy penetrations). We examine 28 locations in the southwestern United States over an 18-year period. The hourly operation of the CSP plants are simulated to determine their potential to provide energy during an eight-hour peak-load window for each day up to 365 days per year. Our result shows that for the large majority of locations and years, CSP plants with certain configurations (i.e., in terms of solar field and TES sizes) can provide nearly 100% peak-load capacity. We examine also the amount of supplemental energy (e.g.,by using natural gas as a supplemental thermal-energy source) that would be required to ensure that a CSP plant could serve the eight highest-load hours of every day of the year. We find that in most cases, a CSP plant supplemented with natural gas would require less than 5% of the fuel that is used by a natural-gas fired power plant providing the same level of reliable capacity. A series of sensitivity analyses show that these results are robust to the number of peak-load hours and days that are considered and the configuration of the CSP plant.

capacity value↗

Heavy and wet: The consequences of violating assumptions of measuring soil microbial growth efficiency using the 18O water method

Soils store more carbon than the biosphere and atmosphere combined, and the efficiency to which soil microorganisms allocate carbon to growth rather than respiration is increasingly considered a proxy for the soil capacity to store carbon. This carbon use efficiency (CUE) is measured via different methods, and more recently, the 18O-H2O method has been embraced as a significant improvement for measuring CUE of soil microbial communities. Based on extrapolating 18O incorporation into DNA to new biomass, this measurement makes various implicit assumptions about the microbial community at hand. Here we conducted a literature review to evaluate how viable these assumptions are and then developed a mathematical model to test how violating them affects estimates of the growth component of CUE in soil. We applied this model to previously collected data from two kinds of soil microbial communities. By changing one parameter at a time, we confirmed our previous observation that CUE was reduced by fungal removal. Our results also show that depending on the microbial community composition, there can be substantial discrepancies between estimated and true microbial growth. Of the numerous implicit assumptions that might be violated, not accounting for the contribution of sources of oxygen other than extracellular water to DNA leads to a consistent underestimation of CUE. We present a framework that allows researchers to evaluate how their experimental conditions may influence their 18O-H2O-based CUE measurements and suggest the parameters that need further constraining to more accurately quantify growth and CUE.

Environmental Sciences & Ecology↗