Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “below- threshold ionization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 847 records · Page 47

Muon Muon Collider: Feasibility Study

A feasibility study is presented of a 2 + 2 TeV muon collider with a luminosity of L = 10{sup 35} cm{sup -2}s{sup -1}. The resulting design is not optimized for performance, and certainly not for cost; however, it does suffice - we believe - to allow us to make a credible case, that a muon collider is a serious possibility for particle physics and, therefore, worthy of R and D support so that the reality of, and interest in, a muon collider can be better assayed. The goal of this support would be to completely assess the physics potential and to evaluate the cost and development of the necessary technology. The muon collider complex consists of components which first produce copious pions, then capture the pions and the resulting muons from their decay; this is followed by an ionization cooling channel to reduce the longitudinal and transverse emittance of the muon beam. The next stage is to accelerate the muons and, finally, inject them into a collider ring wich has a small beta function at the colliding point. This is the first attempt at a point design and it will require further study and optimization. Experimental work will be needed to verify the validity of diverse crucial elements in the design. Muons because of their large mass compared to an electron, do not produce significant synchrotron radiation. As a result there is negligible beamstrahlung and high energy collisions are not limited by this phenomena. In addition, muons can be accelerated in circular devices which will be considerably smaller than two full-energy linacs as required in an e{sup +} - e{sup -} collider. A hadron collider would require a CM energy 5 to 10 times higher than 4 TeV to have an equivalent energy reach. Since the accelerator size is limited by the strength of bending magnets, the hadron collider for the same physics reach would have to be much larger than the muon collider. In addition, muon collisions should be cleaner than hadron collisions. There are many detailed particle reactions which are open to a muon collider and the physics of such reactions - what one learns and the necessary luminosity to see interesting events - are described in detail. Most of the physics accesible to an e{sup +} - e{sup -} collider could be studied in a muon collider. In addition the production of Higgs bosons in the s-channel will allow the measurement of Higgs masses and total widths to high precision; likewise, t{bar t} and W{sup +}W{sup -} threshold studies would yield m{sub t} and m{sub w} to great accuracy. These reactions are at low center of mass energy (if the MSSM is correct) and the luminosity and {Delta}p/p of the beams required for these measurements is detailed in the Physics Chapter. On the other hand, at 2 + 2 TeV, a luminosity of L {approx} 10{sup 35} cm{sup -2}s{sup -1} is desirable for studies such as, the scattering of longitudinal W bosons or the production of heavy scalar particles. Not explored in this work, but worth noting, are the opportunities for muon-proton and muon-heavy ion collisions as well as the enormous richness of such a facility for fixed target physics provided by the intense beams of neutrinos, muons, pions, kaons, antiprotons and spallation neutrons. To see all the interesting physics described herein requires a careful study of the operation of a detector in the very large background. Three sources of background have been identified. The first is from any halo accompanying the muon beams in the collider ring. Very carefully prepared beams will have to be injected and maintained. The second is due to the fact that on average 35% of the muon energy appears in its decay electron. The energy of the electron subsequently is converted into EM showers either from the synchrotron radiation they emit in the collider magnetic field or from direct collision with the surrounding material. The decays that occur as the beams traverse the low beta insert are of particular concern for detector backgrounds. A third source of background is e{sup +} - e{sup -} pair creation from {mu}{sup +} - {mu}{sup -} interaction. Studies of how to shield the detector and reduce the background are addressed in the Detector Chapter. Polarization of the muons allows many very interesting measurements which are discussed in the Physics Chapter. Unlike the electron collider in which the electron beam is highly polarized and the positron beam unpolarized, both muon beams may be partially polarized. It is necessary to select forward moving muons from the pion's decay and thus reduce the available number of muons and hence the luminosity. The necessary machine technology needed to achieve such a collider is discussed in the Option Chapter; at the moment it is not part of our point design, although such capability would almost certainly be incorporated into an actual device.

43 PARTICLE ACCELERATORS↗

Present status of alpha-particle condensed states in 4n self-conjugate nuclei

Low density states near the 3alpha and 4alpha breakup threshold in {sup 12}C and {sup 16}O, respectively, are discussed in terms of the alpha-particle condensation. Calculations are performed in OCM (Orthogonality Condition Model) and THSR (Tohsaki-Horiuchi-Schuck-Roepke) approaches. The 0{sub 2}{sup +} state in {sup 12}C and the 0{sub 6}{sup +} state in {sup 16}O are shown to have dilute density structures and give strong enhancement of the occupation of the S-state c.o.m. orbital of the alpha-particles. The possibility of the existence of alpha-particle condensed states in heavier nalpha nuclei is also discussed.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Gamma-ray strength functions and their relation to astrophysics

The nuclear {gamma}-ray strength function is one of the indispensable inputs needed for reaction-rate calculations, and is particularly important for the neutron-capture cross section. The nuclear physics group at the Oslo Cyclotron Laboratory has developed a method to extract simultaneously nuclear level density and {gamma}-ray strength function from particle-{gamma} coincidence measurements. Data on the strength functions of Sn nuclei as well as for lighter elements are presented. The Sn isotopes all display a resonance-like structure close to the neutron threshold, that could possibly be due to the neutron-skin oscillation mode. This so-called pygmy dipole resonance greatly influences the neutron-capture rates. In the lighter nuclei, an enhancement of the strength function at low {gamma} energies is observed. The possible impact of this increase on Maxwellian-averaged reaction rates has been investigated.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Resonance scattering and alpha-transfer reactions for nuclear astrophysics

Resonances in atomic nuclei play a vital role in determining rates of astrophysically important nuclear reactions. Efficient experimental technique, Thick Target Inverse Kinematics method, which allows to study properties of resonances in exotic nuclei with radioactive beams using resonance elastic scattering is discussed. Various extensions of this technique for measurements of inelastic excitation functions and application of one of these methods for {sup 7}Be(p,p'){sup 7}Be*(0.43 MeV) reaction is considered.The astrophysical rates of some (alpha, gamma), (alpha, n), (alpha, p) reactions are often determined by the near alpha-threshold resonances. Application of sub-Coulomb alpha-transfer reactions ({sup 7}Li,t) and ({sup 6}Li,d) allow to determine alpha-particle Asymptotic Normalization Coefficients of these resonances with minimal dependance on model parameters. The {sup 14}C(alpha,gamma) reaction is considered as an example for application of this approach.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

SU-E-T-798: Verification of 3DVH Dose Distribution Before Clinical Implementation for Patient-Specific IMRT QA

Purpose: In recent years patient-specific IMRT QA has transitioned from film and chamber measurements to beam-by-beam 2D array measurements. 3DVH takes this transition a step further by estimating the 3D dose distribution delivered using 2D per beam diode array measurements. In this study, the 3D dose distribution generated by 3DVH is compared to film and chamber measurements. In addition, the accuracy ROI volume and error detection is investigated. Methods: Composite film and ion chamber measurements in a solid water phantom were performed for 9 IMRT PINNACLE patient plans for 4 treatment sites. The film and chamber measurements were compared to the dose distribution predicted by 3DVH using MAPCHECK2 per beam measurements. The absolute point dose measurement (CAX) was extracted from the predicted 3DVH and PINNACLE dose distribution and was compared by taking the ratio of measured to predicted doses. The dose distribution measured with film was compared to the distribution in the corresponding plane (AX, SAG, COR) extracted from predicted dose distribution by 3DVH and PINNACLE using a 2D gamma analysis. Gamma analysis was performed with 2% dose, 2 mm DTA, 20% threshold, and global normalization. In addition, the percent difference between 3DVH and PINNACLE ROI volumes was calculated. Results: The average ratio of the measured point dose vs the 3DVH predicted dose was 1.017 (σ=0.011). The average gamma passing rate for measured vs 3DVH dose distributions was 95.1% (σ=2.53%). The average percent difference of 3DVH vs PINNACLE ROI volume was 2.29% (σ=2.5%). Conclusion: The dose distributions predicted by 3DVH using MAPCHECK2 measurements are the same as the distributions that would have been obtained using film and chamber. The ROI volumes used in 3DVH are not an exact match to those in PINNACLE; the effect requires more investigation. The accuracy of error detection by 3DVH is currently being investigated.

60 APPLIED LIFE SCIENCES↗

Quantifying the strength and asymmetry of giant resonances in the photorecombination of Sc{sup 3+} and the photoionization of Sc{sup 2+}

We report on strong interference effects for the dominant, highly correlated, broad, and asymmetric 3p{sup 5}3d{sup 2}({sup 2}F{sub 5/2,7/2}{sup o}) giant resonances in the photorecombination of Sc{sup 3+}. Using a nonorthogonal perturbative multiconfiguration Breit-Pauli approach, we present theoretical photorecombination cross sections that are in line with the Test Storage Ring measurements of Schippers et al. In order to reproduce the observed asymmetric resonance profiles near threshold, it was necessary to include resonance-continuum interference. Also, we present Sc{sup 2+} photoionization cross sections that agree with the Advance Light Source measurements of Schippers et al. This perturbative method is based on analytical expressions for the cross sections in terms of computed energies and transition rates, thereby directly determining resonance strengths and Fano asymmetry parameters. Of particular note, our reported absolute cross sections are in excellent agreement with experimental results, in contrast to all previous theoretical calculations. Furthermore, the apparent violation of the sum rule prediction, determined both from our integrated photoionization cross sections and from experimental results, is found to be due to radiative damping of narrow resonances.

74 ATOMIC AND MOLECULAR PHYSICS↗

{gamma}-ray strength function method and its application to {sup 107}Pd

The {gamma}-ray strength function method is devised to indirectly determine radiative neutron capture cross sections for radioactive nuclei. This method is applied here to the {sup 107}Pd (T{sub 1/2}=6.5x10{sup 6} yr) case. Photoneutron cross sections were measured for {sup 105,106,108}Pd near neutron threshold with quasimonochromatic laser-Compton-scattering {gamma}-ray beams. These photoneutron cross sections as well as the reverse radiative neutron capture cross sections for {sup 104,105}Pd are used to provide constraints on the {sup 107}Pd(n,{gamma}){sup 108}Pd cross section.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Conditions for reliable time-resolved dosimetry of electronic portal imaging devices for fixed-gantry IMRT and VMAT

Purpose: The continuous scanning mode of electronic portal imaging devices (EPID) that offers time-resolved information has been newly explored for verifying dynamic radiation deliveries. This study seeks to determine operating conditions (dose rate stability and time resolution) under which that mode can be used accurately for the time-resolved dosimetry of intensity-modulated radiation therapy (IMRT) beams.Methods: The authors have designed the following test beams with variable beam holdoffs and dose rate regulations: a 10 Multiplication-Sign 10 cm open beam to serve as a reference beam; a sliding window (SW) beam utilizing the motion of a pair of multileaf collimator (MLC) leaves outside the 10 Multiplication-Sign 10 cm jaw; a step and shoot (SS) beam to move the pair in step; a volumetric modulated arc therapy (VMAT) beam. The beams were designed in such a way that they all produce the same open beam output of 10 Multiplication-Sign 10 cm. Time-resolved ion chamber measurements at isocenter and time-resolved and integrating EPID measurements were performed for all beams. The time-resolved EPID measurements were evaluated through comparison with the ion chamber and integrating EPID measurements, as the latter are accepted procedures. For two-dimensional, time-resolved evaluation, a VMAT beam with an infield MLC travel was designed. Time-resolved EPID measurements and Monte Carlo calculations of such EPID dose images for this beam were performed and intercompared.Results: For IMRT beams (SW and SS), the authors found disagreement greater than 2%, caused by frame missing of the time-resolved mode. However, frame missing disappeared, yielding agreement better than 2%, when the dose rate of irradiation (and thus the frame acquisition rates) reached a stable and planned rate as the dose of irradiation was raised past certain thresholds (a minimum 12 s of irradiation per shoot used for SS IMRT). For VMAT, the authors found that dose rate does not affect the frame acquisition rate, thereby causing no frame missing. However, serious inplanar nonuniformities were found. This could be overcome by sacrificing temporal resolution (10 frames or 0.95 s/image): the continuous images agreed with ion chamber responses at the center of EPID and the calculation two-dimensionally in a time-resolved manner.Conclusions: The authors have determined conditions under which the continuous mode can be used for time-resolved dosimetry of fixed-gantry IMRT and VMAT and demonstrated it for VMAT.

61 RADIATION PROTECTION AND DOSIMETRY↗

Recent Results on Light Hadron Spectroscopy at BESIII

Using about 226x10{sup 6} J/{psi} events and 106x10{sup 6} {psi}{sup '} events accumulated with BESIII detector operating at BEPCII e{sup +}e{sup -} collider, the existence of pp-bar mass threshold enhancement and X(1835) is confirmed. Two new resonances, X(2120) and X(2370) are also observed in J/{psi}{yields}{gamma}{eta}{sup '}{pi}{sup +}{pi}{sup -}. In the analysis of J/{psi}{yields}{omega}{eta}{pi}{sup +}{pi}{sup -}, a new process J/{psi}{yields}{omega}X(1870){yields}{omega}a{sub 0}(980){pi} is seen with a significance of 7.7{sigma}. In addition, a direct measurement of f{sub 0}(980){yields}a{sub 0}{sup 0}(980) and a{sub 0}{sup 0}(980){yields}f{sub 0}(980) mixing transitions is presented to probe the properties of these two scalar states.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Large-angle {alpha}-particle scattering on {sup 12}C and search for signatures of {alpha}-particle Bose condensation

Evidence of the 3{alpha}-particle condensate character of the Hoyle state (the 0{sub 2}{sup +} state at 7.65 MeV in {sup 12}C) implies not only an enhanced radius of {sup 12}C in this state, which was established by many theoretical calculations and confirmed by the recent diffraction model analysis, but also zero relative angular momenta between clusters. We performed coupled-channels model calculations of the angular distributions of {alpha}+{sup 12}C elastic and inelastic (to the 4.44-MeV 2{sup +}, 7.65-MeV 0{sub 2}{sup +}, and 9.65-MeV 3{sub 1}{sup -} states) scattering at 110 MeV and found the ratio of the empirical spectroscopic factors S(L). As the differential cross sections of these reactions are characterized by pronounced enhancement and strong oscillations at large angles, we assumed a potential scattering in the forward hemisphere and the direct transfer of a {sup 8}Be cluster at {theta}{sub c.m.}>90 deg. and took into account the direct transfer of {sup 8}Be in the ground state and in the first excited 2{sup +} and 4{sup +} states. We found that the cluster configuration with L=0 dominates in the 0{sub 2}{sup +} state, being more than three times larger than that in the ground state. This result provides additional evidence of the condensed structure of the Hoyle state in {sup 12}C with a dominance of zero relative angular momentum. The negative-parity 3{sub 1}{sup -} excited state in {sup 12}C observed above the 3{alpha} threshold is also considered to have the 3{alpha}-cluster structure. The present calculations described well the structure of the large-angle cross section on this state. We found a positive interference for all allowed {alpha}+{sup 8}Be configurations with a dominance of the p-orbital (69%){alpha}+{sup 8}Be motion and confirmed the exotic, but hardly a condensed, structure of this state.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

High-precision {sup 28}Si(p,t){sup 26}Si reaction to determine {sup 22}Mg({alpha},p){sup 25}Al reaction rates

The rise time of stellar x-ray bursts is a signature of thermonuclear runaway processes in the atmosphere of neutron stars and is highly sensitive to a series of ({alpha},p) reactions via high-lying resonances in sd-shell nuclei. Lacking data for the relevant resonance levels, the stellar reaction rates have been calculated using statistical, Hauser-Feshbach models, assuming a high-level density. This assumption may not be correct in view of the selectivity of the ({alpha},p) reaction to natural parity states. We measured the {sup 28}Si(p,t){sup 26}Si reaction with a high-resolution spectrometer to identify resonance levels in {sup 26}Si above the {alpha}-emission threshold at 9.164 MeV excitation energy. These resonance levels are used to calculate the stellar reaction rate of the {sup 22}Mg({alpha},p){sup 25}Al reaction and to test the validity of the statistical assumption.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Photoionization of iodine atoms: Rydberg series which converge to the I{sup +}({sup 1}S{sub 0})<-I({sup 2}P{sub 3/2}) threshold

Relative partial photoionization cross sections and angular distribution parameters {beta} have been measured for the first and fourth (5p){sup -1} photoelectron (PE) bands of atomic iodine by performing angle-resolved constant-ionic-state (CIS) measurements on these PE bands between the {sup 1}D{sub 2} and {sup 1}S{sub 0} (5p){sup -1} ionic thresholds in the photon energy region of 12.9-14.1 eV. Rydberg series arising from the 5p{yields}ns and 5p{yields}nd excitations are observed in both the first PE band, I{sup +}({sup 3}P{sub 2})<-I({sup 2}P{sub 3/2}), and the fourth PE band, I{sup +}({sup 1}D{sub 2})<-I({sup 2}P{sub 3/2}), CIS spectra. For each Rydberg state, the resonance energy, quantum defect, linewidth, line shape, and photoelectron angular distribution parameter {beta} have been determined. For the {beta}-plots for each PE band, only resonances corresponding to 5p{yields}nd excitations are observed; no resonances were seen at photon energies corresponding to the 5p{yields}ns resonances in the CIS spectra. The {beta}-plots are interpreted in terms of the parity unfavored channel with j{sub t}=4 being the major contributor at the 5p{yields}nd resonance positions, where j{sub t} is the quantum number for angular momentum transferred between the molecule, and the ion and photoelectron. Comparison of the results obtained with those published for bromine shows reasonably good agreement for the CIS spectra but poor agreement for the {beta}-plots. It appears that parity unfavored channels are playing a greater role in the valence (np){sup -1} ionization of atomic iodine than in the corresponding ionization of atomic bromine.

74 ATOMIC AND MOLECULAR PHYSICS↗

Energy variation of double K -shell photoionization of Ne

Herein we report on an experimental and theoretical study of double K-shell photoionization of Ne over the 2.3–8.5 keV x-ray energy range. The ratio of double-to-single K-shell photoionization cross sections was determined experimentally by measuring the relative rates of the KK–KL 2,3 L 2,3 ( 2 D) Auger hypersatellite and the K–L 2,3 L 2,3 ( 1 D) diagram Auger transitions. By scaling the hypersatellite-diagram Auger-electron ratios to KK/K cross-section ratios, comparison was made with theoretical cross-section ratios of He-like Ne 8+ determined by the R matrix with pseudostates method. The experimental Ne and theoretical Ne 8+ cross-section ratios show similar variations with energy, but the experimental ratios systematically exceed the calculated ratios and also show a lower threshold energy for double K-shell photoionization onset compared to the computed Ne 8+ threshold. The discrepancy is attributed to effects of L-shell electrons not included in the He-like Ne 8+ calculations. Quantified scaling with nuclear charge Z along the He-like isoelectronic sequence indicates that the measured 10-electron Z = 10 double K-shell photoionization cross section behaves like the computed He-like Z = 8.9 cross section, suggesting an effective nuclear screening parameter of s L =1.1 by the additional eight outer L-shell electrons. Experimental results for the energy variations of Auger electron transitions from other multielectron hole states are also discussed.

74 ATOMIC AND MOLECULAR PHYSICS↗

Sympathetic Cooling of Molecular Ions in Selected Rotational and Vibrational States Produced by Threshold Photoionization

We present a new method for the generation of rotationally and vibrationally state-selected, translationally cold molecular ions in ion traps. Our technique is based on the state-selective threshold photoionization of neutral molecules followed by sympathetic cooling of the resulting ions with laser-cooled calcium ions. Using N{sub 2}{sup +} ions as a test system, we achieve >90% selectivity in the preparation of the ground rovibrational level and state lifetimes on the order of 15 minutes limited by collisions with background-gas molecules. The technique can be employed to produce a wide range of apolar and polar molecular ions in the ground and excited rovibrational states. Our approach opens up new perspectives for cold quantum-controlled ion-molecule-collision studies, frequency-metrology experiments with state-selected molecular ions and molecular-ion qubits.

74 ATOMIC AND MOLECULAR PHYSICS↗

SEARCH FOR VERY HIGH ENERGY GAMMA-RAY EMISSION FROM PULSAR-PULSAR WIND NEBULA SYSTEMS WITH THE MAGIC TELESCOPE

The MAGIC collaboration has searched for high-energy gamma-ray emission of some of the most promising pulsar candidates above an energy threshold of 50 GeV, an energy not reachable up to now by other ground-based instruments. Neither pulsed nor steady gamma-ray emission has been observed at energies of 100 GeV from the classical radio pulsars PSR J0205+6449 and PSR J2229+6114 (and their nebulae 3C58 and Boomerang, respectively) and the millisecond pulsar PSR J0218+4232. Here, we present the flux upper limits for these sources and discuss their implications in the context of current model predictions.

79 ASTRONOMY AND ASTROPHYSICS↗

Resonant and Near-Threshold Photoionization Cross Sections of Fe{sup 14+}

Photoionization (PI) of Fe{sup 14+} in the range from 450 to 1100 eV was measured at the BESSY II storage ring using an electron beam ion trap achieving high target-ion area densities of 10{sup 10} cm{sup -2}. Photoabsorption by this ion is observed in astrophysical spectra and plasmas, but until now cross sections and resonance energies could only be provided by calculations. We reach a resolving power E/{Delta}E of at least 6500, outstanding in the present energy range, which enables benchmarking and improving the most advanced theories for PI of ions in high charge states.

74 ATOMIC AND MOLECULAR PHYSICS↗

Parton fragment yields derived from minimum-bias jet angular correlations

The unbiased spectra of fragments from large-angle-scattered partons (midrapidity parton fragment distributions) in 200 GeV Au-Au collisions can be accurately described by perturbative QCD (pQCD) methods, revealing that a substantial population of parton fragments is present in hadron spectra at low transverse momentum (p{sub t}). Angular correlations including all accepted hadron pairs above some low threshold p{sub t} (minimum-bias correlations) contain jetlike structures with most-probable hadron momentum {approx}1 GeV/c. In this study, we convert minimum-bias jetlike angular correlations to single-particle hadron yields and compare them with parton fragment yields inferred from differential spectrum analysis (spectrum hard components). We find that jetlike correlations in central 200 GeV Au-Au collisions correspond quantitatively to pQCD predictions, and the jet-correlated hadron yield comprises one third of the Au-Au final state in central collisions.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

VERY HIGH ENERGY OBSERVATIONS OF GAMMA-RAY BURSTS WITH STACEE

Gamma-ray bursts (GRBs) are the most powerful explosions known in the universe. Sensitive measurements of the high-energy spectra of GRBs can place important constraints on the burst environments and radiation processes. Until recently, there were no observations during the first few minutes of GRB afterglows in the energy range between 30 GeV and {approx}1 TeV. With the launch of the Swift GRB Explorer in late 2004, GRB alerts and localizations within seconds of the bursts became available. The Solar Tower Atmospheric Cherenkov Effect Experiment (STACEE) was a ground-based, gamma-ray telescope with an energy threshold of {approx}150 GeV for sources at zenith. At the time of Swift's launch, STACEE was in a rare position to provide >150 GeV follow-up observations of GRBs as fast as three minutes after the burst alert. In addition, STACEE performed follow-up observations of several GRBs that were localized by the HETE-2 and INTEGRAL satellites. Between 2002 June and 2007 July, STACEE made follow-up observations of 23 GRBs. Upper limits are placed on the high-energy gamma-ray fluxes from 21 of these bursts.

79 ASTRONOMY AND ASTROPHYSICS↗