Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “beams”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 847 records · Page 47

Filament-induced breakdown spectroscopy with structured beams

Filament-induced ablation represents an attractive scheme for long-range material identification via optical spectroscopy. However, the delivery of laser energy to the target can be severely hindered by the stochastic nature of multiple-filamentation, ionization of ambient gas, and atmospheric turbulence. In order to mitigate some of these adverse effects, we examine the utility of beam shaping for femtosecond filament-induced breakdown spectroscopy with Gaussian and structured (Laguerre-Gaussian, Airy, and Bessel-Gaussian) beams in the nonlinear regime. Interaction of filaments with copper, zinc, and brass targets was studied by recording axially-resolved broadband emission from the filament-induced plasma. The laser-solid coupling efficacy was assessed by inferring thermodynamic parameters such as excitation temperature and electron density. While under our experimental conditions the ablation rate with Gaussian- and Laguerre-Gaussian beams is found to be similar, the Airy and Bessel-Gaussian beams offer the advantage of longitudinally extended working zones. These results provide insights into potential benefits of structuring ultrafast laser beams for standoff sensing applications.

47 OTHER INSTRUMENTATION↗

High-energy X-ray radiography with apodized petawatt laser beams

We have produced laser wakefield-accelerated electron beams with energies of 2 GeV in Target Area 1 of the ZEUS facility. These electron beams oscillate in the accelerating structure that is produced in the wake of an ultrashort laser pulse (25 fs). These ’betatron’ oscillations result in the emission of a collimated (4 mrad divergence) beam of high-energy X-ray/gamma photons (on the order of several hundred keV). In this work, we demonstrate the capabilities of the ZEUS laser system by showing that apodizing the laser beam in the near field allows for the production of high-quality betatron X-rays for radiography purposes. This demonstrates that a high-power, large-aperture laser beam could be split into multiple parts to drive betatron X-ray sources from multiple angles or temporal delays into a High Energy Density (HED) target to be probed, enabling pump-probe measurements at multiple temporal delays or tomography on a single shot.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Manipulation of the orbital angular momentum of soft X-ray beams by consecutive diffractive optics

Production and manipulation of orbital angular momentum (OAM) of coherent soft X-ray beams is demonstrated utilizing consecutive diffractive optics. OAM addition is observed upon passing the beam through consecutive fork gratings. Here, the OAM of the beam was found to be decoupled from its spin angular momentum (SAM). Practical implementation of angular momentum control by consecutive devices in the X-ray regime opens new experimental opportunities, such as direct measurement of the beam’s OAM without resorting to phase-sensitive techniques, including holography. OAM analyzers utilizing fork gratings can be used to characterize the beams produced by synchrotron and free electron lasers sources; they can also be used in scattering experiments.

36 MATERIALS SCIENCE↗

Electron-beam-driven chemical processes during liquid phase transmission electron microscopy

Liquid phase (or liquid cell) transmission electron microscopy (LP-TEM) has been established as a powerful tool for observing dynamic processes in liquids at nanometer to atomic length scales. However, the simple act of observation using electrons irreversibly alters the nature of the sample. A clear understanding of electron beam-driven processes during LP-TEM is required to interpret in situ observations and utilize the electron beam as a stimulus to drive nanoscale dynamic processes. In this review, we discuss recent advances toward understanding, quantifying, mitigating, and harnessing electron beam-driven chemical processes occurring during LP-TEM. We will highlight progress in several research areas, including modeling electron beam-induced radiolysis near interfaces, electron beam-induced nanocrystal formation, and radiation damage of soft materials and biomolecules.

Woehl, Taylor J.↗

Strategies to overcome electron-beam issues in liquid phase TEM: Study of chemical processes

Abstract Liquid phase (or liquid cell) transmission electron microscopy (TEM) has become a powerful platform for in situ investigation of various chemical processes at the nanometer or atomic level. The electron beam for imaging can also induce perturbation to the chemical processes. Thus, it has been a concern that the observed phenomena in a liquid cell could deviate from the real-world processes. Strategies have been developed to overcome the electron-beam-induced issues. This article provides an overview of the electron-beam effects, and discusses various strategies in liquid cell TEM study of nucleation, growth, and self-assembly of nanoscale materials, where an electron beam is often used to initiate the reactions, and highly electron-beam-sensitive electrochemical reactions. Graphical abstract

Zheng, Wenjing↗

FRIB Beam Power Ramp-up: Status and Plans

After project completion on scope, on cost, and ahead of schedule, the Facility for Rare Isotope Beams began operations for scientific users in May of 2022. The ramp-up to a beam power of 400 kW is planned over a six-year period; 1 kW was delivered for initial user runs from in 2022, and 5 kW was delivered as of February 2023. Test runs with 10 kW 36Ar and 48Ca beams were conducted in July 2023. Upgrade plans include doubling the primary-beam energy to 400 MeV/nucleon for enhanced discovery potential (¿FRIB 400¿). This talk reports on the strategic plans towards high power operations emphasizing challenges and resolutions in beam-interception devices and targetry systems, radiation protection and controls, and legacy system renovation and integration.

43 PARTICLE ACCELERATORS↗

Electron bunch position determination using a high frequency button beam position monitor in the AWAKE facility

The AWAKE facility uses novel proton beam-driven plasma wakefields to accelerate electron bunches over 10m of Rubidium plasma. Precise monitoring of 2 diverse beam types necessitates an electron beam position monitor (BPM) working in a frequency regime of tens of GHz. A high frequency conical button-style BPM with a working regime of up to 40 GHz has been investigated as a way to discriminate the electromagnetic fields of 19 MeV, 4 ps electron bunches propagating spatially and temporally together with a 400 GeV, 170 ps proton bunch in the AWAKE common beamline. The sensitivity of the HF BPM to the electron beam position is determined under various beam conditions, with both electrons and protons, and integration with a TRIUMF front-end is discussed.

43 PARTICLE ACCELERATORS↗

Three Approaches for Complete Measurement of the Transverse Beam Optics Along the Fermilab Muon Campus Extraction Line

Traditionally, the process of measuring the optical parameters of a beamline has employed the use of one of two standard methods, namely the three-screen method or a quadrupole magnet scan. Both require either an area of zero dispersion to perform the measurements or knowledge of the dispersion function and momentum spread beforehand in order to provide accurate results. There is however a third method that can be used to measure the standard optical parameters, the beam parameters, the dispersion function, and the momentum spread simultaneously. This method, aptly named the six-screen method, is an extension of the more standard three-screen method. Utilizing the simulation environment of G4beamline, we simulated the 8 GeV proton beam in the M4 beamline and measured the optical and beam parameters using the two standard approaches. Those results were then used as a reference to check the viability of employing the less standard six-screen method in the M4 line. If shown to be a viable option, the six-screen method could be used to retrieve the dispersion function and momentum spread of the beam without needing to change the energy of the beam.

43 PARTICLE ACCELERATORS↗

Real-Time Edge AI for Distributed Systems (READS): Progress on Beam Loss De-Blending for the Fermilab Main Injector and Recycler

The Fermilab Main Injector enclosure houses two accelerators, the Main Injector and Recycler. During normal operation, high intensity proton beams exist simultaneously in both. The two accelerators share the same beam loss monitors (BLM) and monitoring system. Beam losses in the Main Injector enclosure are monitored for tuning the accelerators and machine protection. Losses are currently attributed to a specific machine based on timing. However, this method alone is insufficient and often inaccurate, resulting in more difficult machine tuning and unnecessary machine downtime. Machine experts can often distinguish the correct source of beam loss. This suggests a machine learning (ML) model may be producible to help de-blend losses between machines. Work is underway as part of the Fermilab Real-time Edge AI for Distributed Systems Project (READS) to develop a ML empowered system that collects streamed BLM data and additional machine readings to infer in real-time, which machine generated beam loss.

43 PARTICLE ACCELERATORS↗

Design of a 10 MeV beamline at the Upgraded Injector Test Facility for e-beam irradiation

Electron beam irradiation near 10 MeV is suitable for wastewater treatment. The Upgraded Injector Test Facility (UITF) at Jefferson Lab is a CW superconducting linear accelerator capable of providing an electron beam of energy up to 10 MeV and up to 100 µA current. This contribution presents the beam transport simulations for a beamline to be used for the irradiation of wastewater samples at the UITF. The simulations were done using the code General Particle Tracer with the goal of obtaining an 8 MeV electron beam of radius (3-σ) of ~2.4 cm. The achieved energy spread is ~74.5 keV. The space charge effects were investigated when the bunch charge is varied to be up to 1000 times and the results showed that they do not affect the beam quality significantly.

Li, X.↗

Simulation Studies on the Interactions of Electron Beam with Wastewater

The manufactured chemical pollutants, like 1,4 dioxane and PFAS (per- and polyfluroralkyl substances), found in the underground water and/or drinking water are challenging to be removed or biodegraded. Energetic electrons are capable of mediating and removing them. This paper utilizes FLUKA code to evaluate the beam-wastewater interaction effects with different energy, space and divergence distributions of the electron beam. With 8 MeV average energy, the electron beam exits from a 0.0127 cm thick titanium window, travels through a 4.3 cm distance air and a second 0.0127 cm thick stainless water container window with 2.43 cm radius, and finally is injected into the water area, where the volume of water is around 75 cubic cm. The distribution parameters of the electron beam are from the GPT (General Particle Tracer) simulations for UITF (Upgraded Injector Test Facility) in Jefferson lab. By varying the distributions, several measurements including the dose (or energy deposition) distribution, electron fluence, photon fluence are scored and compared. Taking the comparisons into consideration, this paper is aiming to find better electron beams for the wastewater irradiation.

Li, X.↗

Measurement of Beam Energy in the Fermilab's Linac taken at the Transfer Line

Linac is the first machine in the accelerator chain at Fermilab where H$^{-}$ ions are accelerated from 35 keV to 401.5\,MeV and then injected into a synchronton known as Booster where they are stripped of their electrons to become protons. One of the tools used during tuning of the Linac extraction energy is two beam pickups known as Griffin Detectors. Our goal is to control the output energy using machine learning techniques to increase the reliability and quality of the beam delivered from Linac. The first step is to understand the data from the diagnostics to develop reliable and accurate energy measurement, and control methods before implementing machine learning techniques. Two methods of energy measurement were studied, and their results are compared. The first method was the time of flight measurement using Beam Position Monitors that provide beam phase measurement. The second method used the relation between beam transverse positions and dispersion values to calculate momentum variation. The results of these two measurement methods are found to be consistent.

43 PARTICLE ACCELERATORS↗

Status of the laser manipulations of H- beam at J-PARC

The laser manipulations of H- ion beam by single or double neutralization is a very promising technique and highly essential to utilized in accelerator processes such as stripping, pulse chopping, collimation, extraction, and beam diagnostics for the present and future high-intensity proton accelerators. At J-PARC, we are preparing for a POP (Proof-of-Principle) demonstration 400 MeV H- stripping by using only lasers. A prototype YAG laser system and a laser cavity system to reduce the laser power are being developed through 3 MeV H- neutralization studies. Fermilab utilizes H- neutralization at 0.75 MeV by establishing a laser Notcher system for a gap in the H- pulse needed for a clean beam extraction from the ring. To minimize the laser power and maximize the interaction efficiency are common issue at both laboratories. Under the US-Japan collaboration for high-intensity neutrino beam, we are closely working to establish recycling/reusing of seed laser pulses to reduce a size of the laser system. In parallel, we have also developed non-destructive beam diagnostic systems at lower H- energy of 3 MeV, which will be implemented to the 400 MeV as well as easily applicable to the Fermilab linac including PIP-II linac. Installation of the laser system at J-PARC linac for 400 MeV H- stripping is ongoing to start the POP experimental study in 2023.

43 PARTICLE ACCELERATORS↗

Near-infrared noise in intense electron beams

Requirements for the noise in electron beams (NEB) have recently approached the Shot-noise level in some new applications. The density fluctuations of intense beams in the near-infrared (NIR) region are being measured at the Fermilab Accelerator Science and Technology (FAST) facility. The main goal of the experiment is to accurately compare the Shot-noise model with the observations of optical transition radiation (OTR) generated by the gamma=63 electron beam transiting an Al metal surface. In addition, evidence for longitudinal-space-charge-induced microbunching for the chicane-compressed beam was obtained with coherent enhancements up to 100 in the various bandwidth-filtered NIR OTR photodiode signals. With micropulse charges up to 1 nC, the beam parameters are close to those proposed for a stage in an Electron-Ion Collider (EIC) with coherent electron cooling (CEC). In this paper we present the current progress of the NEB project and compare the low electron energy measurements with ImpactX simulations.

43 PARTICLE ACCELERATORS↗

Measurements of the beam longitudinal properties in the Fermilab Linac

The Fermilab Linac delivers 400$\,$MeV, 25$\,$mA H$^-$ beam to a rapid cycling synchrotron called the Booster. Parameters of the Linac beam affect Booster performance and therefore quantifying them is important. The longitudinal bunch parameters are reconstructed using a Bunch Shape Monitor (BSM) installed in the middle of the Linac. For that, the bunch length is measured as a function of the phase of an upstream cavity and fitted to simulations. The cavity gradient and its phase with respect to the beam are recovered from readings of Beam Position Monitors. Since the cavity provides a significant transverse defocusing, the BSM measurements are correlated with transverse beam size measurements by a wire scanner. Simulations connect these three types of measurements, allowing to deduce the longitudinal emittance and Courant-Snyder parameters.

Sharankova, Ralitsa [Fermilab] (ORCID:000000027014↗

Beam-ion Studies in NSTX and NSTX-U (Final Technical Report)

The confinement of high energy "fast ions" is crucial for the success of magnetic fusion as a practical energy source. The research performed by UC Irvine on NSTX and NSTX-U provided new information about this important topic in the configuration known as a "spherical tokamak." Injected neutral beams provided the fast ions (also known as "beam ions"). There were five overarching goals of the research. One objective was to measure the confinement of beam ions in order to ascertain if they were accomplishing their desired purpose of transferring their energy to the bulk plasma. A second goal was to better understand instabilities that are driven unstable by the fast ions. A related goal was to use the similarities and differences between NSTX and the DIII-D conventional tokamak to better understand the fast-ion driven instabilities. A fourth goal was to develop new instruments to measure fast ions and techniques that facilitate analysis of the data. The fifth objective was to measure and understand acceleration of beam ions by RF waves. Much was accomplished in all of these five areas. In the first, it was shown that the large magnetic moment of the beam ions did not harm confinement but instabilities known as the "sawtooth" and "long-lived mode" do. In the second area, much attention was devoted to the fast-ion instabilities known as "Alfvén eigenmodes." In particular, Alfvén eigenmode "avalanches" can cause ~ 30% of the fast ions to be lost in a single explosive burst. The comparative studies with DIII-D showed that an instability discovered on NSTX is also important in conventional tokamaks. In the fourth category, several instruments were developed, a number of effects that complicate interpretation of the data were understood, and progress toward a new method to infer the fast-ion distribution function from the data was made. In the fifth category, the measured profile of accelerated fast ions was initially much broader than theoretical predictions but subsequent improvements in the theoretical modeling achieved good agreement with the data.

43 PARTICLE ACCELERATORS↗

Time-resolved measurement of electron beam neutralization

An intense relativistic electron beam (IREB) incident on a target generates positive ions by stimulated and thermal desorption of adsorbed gas, and subsequent electron impact ionization. These ions are accelerated upstream by the beam space-charge potential, thereby partially neutralizing the beam. If there is enough neutralization, the repulsive space-charge force can be overcome by the magnetic-pinch force due to the beam current. This so-called ion focusing is responsible for time dependent defocusing of the radiographic source spot. Since a single monolayer of adsorbed gas has a surface density of about 10 15 /cm 2 and is formed in about one second in a one micro-Torr vacuum, there is always enough adsorbed gas to make this a concern in our accelerators. Therefore, time-resolved measurements of the degree of neutralization are valuable for better understanding of this process with an eye to mitigation for improvement of our radiography. Moreover, these measurements would aid quantification of uncertainties due to these effects when using invasive beam diagnostics, such as OTR imaging targets.

43 PARTICLE ACCELERATORS↗

Enhanced Beam Diagnostics with Existing BPPMs via GPU-powered Multi-Particle Simulation

This research aims to utilize the multi-particle code, High-Performance Simulator (HPSim), to realistically model the Side-Coupled-Cavity Linac (CCL) lattice of the LANSCE accelerator. This new model would allow us to predict the beam’s bunch length (the longitudinal spread), which is unavailable for individual accelerating modules or only accessible at the end of the linac. However, a correct bunch length is critical for the high-energy beam transport after the CCL. Its impact would be most significant in the Proton Storage Ring (PSR), where we should be able to reduce losses for the circulating beam. The PSR is scheduled to have a 25% current increase for the neutron spallation target upgrade at the Lujan Center. A highly bunched beam would be necessary to reduce the particle losses and lower the radiation levels produced from the ring. A realistic HPSim model with >1M macro-particles can help tackle the beam losses at the sub-percent level. This new work would also create a realistic surrogate model for future machine learning projects.

43 PARTICLE ACCELERATORS↗