Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “beam techniques”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 847 records · Page 47

Development of the Electron Drift Instrument (EDI) for Cluster

The Electron Drift Instrument (EDI) is a new technique for measuring electric fields in space by detecting the effect on weak beams of test electrons. This U.S. portions of the technique, flight hardware, and flight software were developed for the Cluster mission under this contract. Dr. Goetz Paschmann of the Max Planck Institute in Garching, Germany, was the Principle Investigator for Cluster EDI. Hardware for Cluster was developed in the U.S. at the University of New Hampshire, Lockheed Palo Alto Research Laboratory, and University of California, San Diego. The Cluster satellites carrying the original EDI instruments were lost in the catastrophic launch failure of first flight of the Arianne-V rocket in 1996. Following that loss, NASA and ESA approved a rebuild of the Cluster mission, for which all four satellites were successfully launched in the Summer of 2000. Limited operations of EDI were also obtained on the Equator-S satellite, which was launched in December, 1997. A satellite failure caused a loss of the Equator-S mission after only 5 months, but these operations were extremely valuable in learning about the characteristics and operations of the complex EDI instrument. The Cluster mission, satellites, and instruments underwent an extensive on-orbit commissioning phase in the Fall of 2000, carrying over through January 2001. During this period all elements of the instruments were checked and careful measurements of inter-experiments interferences were made. EDI is currently working exceptionally well in orbit. Initial results verify that all aspects of the instrument are working as planned, and returning highly valuable scientific information. The first two papers describing EDI on-orbit results have been submitted for publication in April, 2001. The principles of the EDI technique, and its implementation on Cluster are described in two papers by Paschmann et al., attached as Appendices A and B. The EDI presentation at the formal Cluster Commissioning Review, held at ESA Headquarters in Paris, is attached as Appendix C.

Quinn, Jack↗

Grazing incidence neutron optics

Neutron optics based on the two-reflection geometries are capable of controlling beams of long wavelength neutrons with low angular divergence. The preferred mirror fabrication technique is a replication process with electroform nickel replication process being preferable. In the preliminary demonstration test an electroform nickel optics gave the neutron current density gain at the focal spot of the mirror at least 8 for neutron wavelengths in the range from 6 to 20 .ANG.. The replication techniques can be also be used to fabricate neutron beam controlling guides.

Gubarev, Mikhail V.↗

Grazing Incidence Neutron Optics

Neutron optics based on the two-reflection geometries are capable of controlling beams of long wavelength neutrons with low angular divergence. The preferred mirror fabrication technique is a replication process with electroform nickel replication process being preferable. In the preliminary demonstration test an electroform nickel optics gave the neutron current density gain at the focal spot of the mirror at least 8 for neutron wavelengths in the range from 6 to 20.ANG.. The replication techniques can be also be used to fabricate neutron beam controlling guides.

Gubarev, Mikhail V.↗

New Trends in Coatings Developments for Turbine Blades: Materials Processing and Repair

Turbine engines for aeronautic applications now have to face strenuous requirements concerning not only operating performances but also reliability and repairability. This evolution of the specifications induces important consequences regarding the choice and the design of turbine blade protective coatings. This paper presents several key features concerning the deposition techniques and the real-life behavior of such coatings: (1) complex aluminides well suited to the protection against high temperature oxidation and hot corrosion of directionally solidified nickel-base superalloy turbine blades; (2) ceramic coatings used as thermal barriers - they have to exhibit both high resistance to thermomechanical fatigue and adequate smoothness; (3) processing techniques for thermal barriers, including plasma spraying, electron beam physical vapor deposition and plasma enhanced chemical vapor deposition; and (4) blades and coatings repair techniques.

S Alpérine↗

Mid-IR interferometric nulling for TPF

By the middle of 2006, the Interferometry Technology development program for NASA’s Terrestrial Planet Finder (TPF) Mission has the goal of demonstrating deep and stable interferometric nulling of broadband Mid-IR thermal radiation under conditions that are traceable to the expected on-orbit conditions. Specifically, the task is to demonstrate null levels of 10 to the negative 6 power, with a 50% BW centered at 10 um, with null stabilities of 10 to the negative 7 power all at cryogenic temperatures for observational periods of a couple of hours. The Achromatic Nulling activity at JPL addresses this concern in two testbeds: the warm nulling testbed and the cryonulling testbed. The warm nulling testbed will demonstrate the physics of nulling broadband thermal sources in an environment that is conducive to efficient research. We’ll explore nulling techniques, optical-mechanical alignment methods, motion control, and path-length metrology for a single beam interferometer, as well as preliminary planet detection techniques. Ultimate nulling capabilities under conditions that are more flight-like will be demonstrated in cryogenic nulling testbed. Knowledge gained from operation at room temperature will be applied to the cryongenic experiment where we face the additional challenges of extreme temperatures, cryongenic actuators, component survivability and fluxes that are within an order of magnitude of expected flux levels on orbit. Concurrently, we will develop a low flux mid-IR camera that will allow us to measure the nulls at these faint photon fluxes. This talk will review this development activity and will include recent nulling experimental results and plans for future work.

Vasisht, Gautam↗

Direct reactions for astrophysical p-capture rates with ORRUBA and GODDESS

Understanding the nucleosynthesis and energy generation in quiescent and explosive stellar burning requires a detailed understanding of reaction rates on many unstable nuclides. Such reaction rates are often governed by the properties of low-lying, isolated proton resonances. Though direct measurements of resonance strengths are ultimately desired, and are a focus of rare isotope beam facilities worldwide, such tour-de-force experiments must be guided by indirect techniques, in order to know resonance energies, J π assignments, and estimated widths, to inform targeted measurements. Furthermore, some important low-lying resonances may be too weak for direct measurements with radioactive beams, and indirect techniques provide the only practical constraints. Additionally, there has been growing interest in the astrophysical role of isomeric states, which can influence the reaction flow in nucleosynthetic reaction networks, and hence impact the quantitative interpretation of astronomical observables, such as γ-ray signatures, and elemental and isotopic ratios. Properties of single-proton resonances can be obtained by exploiting the selectivity of direct reactions, such as single-nucleon transfer and charge-exchange reactions. Constraining proton-capture rates via direct reactions has been a focus of the astrophysics program at ORNL for over two decades, spurring the development of the ORRUBA and GODDESS detector systems. Herein, a review of recent developments in instrumentation and radioactive beam delivery (including isomeric beam experiments) is presented, along with some specific examples of astrophysically interesting sd-shell nuclides, which have been a target of recent ORRUBA and GODDESS experiments.

79 ASTRONOMY AND ASTROPHYSICS↗

Proof-of-concept studies of novel protocols for producing highly pure 48 V from a 48 Cr/ 48 V generator

Here, the quest to improve the quality of nuclear data, such as half-lives, transition yields, and reaction cross-sections, is a shared endeavor among various areas of nuclear science. 48 V is a vanadium isotope for which experimental data on neutron reaction cross-sections is needed. However, traditional isotope production techniques cannot produce 48 V with high enough isotopic purity for some of these measurements. “Isotope harvesting” at the Facility for Rare Isotope Beams (FRIB) is a new isotope production technique that could potentially yield 48 V with the necessary purity for such studies. In this case, 48Cr would be collected and allowed to generate 48 V that can be separated from undecayed 48 Cr to yield highly pure 48 V. Thus, any protocol for producing pure 48 V via isotope harvesting would involve utilizing a separation technique that can effectively separate 48 Cr and 48 V. In this study, the radiotracers 51 Cr and 48 V were used to develop possible radiochemical separation methodologies, which can be translated to obtain high purity 48 V via this novel isotope production method. The developed protocols utilize either ion exchange or extraction chromatographic resins. Separations of 51 Cr and 48 V with AG 1-X8 anion exchange resin respectively resulted in recoveries of 95.6(26)% and 96.2(12)% with radionuclidic purities of 92(2)% and 99(1)%. An even more effective Cr and V separation was obtained with an extraction chromatographic resin (TRU resin) and 10 M HNO 3 loading solution. Here, 51 Cr and 48 V respectively had recoveries of 94.1(28)% and 96.2(13)% with high radionuclidic purities (100(2)% and 100(1)%) in small volumes (8.81(8) mL and 5.39(16) mL). This study suggests that, to maximize the yield and isotopic purity of 48 V, the best production protocol would involve utilizing two separations with TRU resin and 10 M HNO 3 to isolate 48 Cr and purify the generated 48 V.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Atomically Precise Surface Engineering for Producing Imagers

High-quality surface coatings, and techniques combining the atomic precision of molecular beam epitaxy and atomic layer deposition, to fabricate such high-quality surface coatings are provided. The coatings made in accordance with the techniques set forth by the invention are shown to be capable of forming silicon CCD detectors that demonstrate world record detector quantum efficiency (>50%) in the near and far ultraviolet (155 nm-300 nm). The surface engineering approaches used demonstrate the robustness of detector performance that is obtained by achieving atomic level precision at all steps in the coating fabrication process. As proof of concept, the characterization, materials, and exemplary devices produced are presented along with a comparison to other approaches.

Greer, Frank↗

Neutral beam dose and sputtering characteristics in an ion implantation system

A technique and instrument design for calorimetric detection of the neutral atom content of a 60 keV argon ion beam. A beam sampling method is used to measure local heat flux to a small platinum wire at steady state; integration of power density profiles leads to a determination of equivalent neutral beam current. The fast neutral production occurs as a result of charge transfer processes in the region of the beam system between analyzing magnet and beam stop where the pressure remains less than .00001 torr. A description of the neutral beam detector is given in section along with a presentation of results. An elementary analysis of sputter material transport from target to substrate was performed; the analysis relates to semiconductor sputtering.

Roberts, A. S., Jr.↗

A development of wide dynamic-range halo monitor for 8 GeV proton beams at FNAL

The FNAL accelerator complex has been upgrading in increasing beam intensity and beam quality. A new beam halo diagnostic device is required in the beam transport line between booster and Recycler. For this purpose, it was decided to introduce the wide dynamic range monitor technique that was developed in 2012 and has been in operation at the J-PARC beam transport line. The device is a two-dimensional beam profile monitor, and it has a dynamic range of approximately six digits of magnitude by using of Optical Transition Radiation and fluorescence screens. Eliminating harmful beam halos is the most important technique for high-intensity proton accelerators. Therefore, beam halo diagnosis is indispensable and becomes more and more important. New FNAL device has been manufactured in a collaboration between J-PARC and FNAL as a part of U.S.-Japan Science and Technology Cooperation Program in High Energy Physics. The equipment will be manufactured at J-PARC and will be shipped to FNAL in 2025.We designed the device to satisfy FNAL specifications: the beam energy, intensity, and size. Currently, most of the equipments are under construction. The large-aperture optical system has been completed and its optical characteristics are being evaluated at J-PARC. We have been also investigating measurement methods corresponding to FNAL bunch trains. This paper reports on the current status of these developments.

43 PARTICLE ACCELERATORS↗

X-ray and Optical Circular Dichroism as Local and Global Ultrafast Chiral Probes of [12]Helicene Racemization

Optical circular dichroism (OCD) is a well-established technique for probing molecular chirality typically in the UV-visible window. Although molecular chirality is usually related to a chiral center, it can alternatively describe a global structure. The electronic transitions are then delocalized and OCD is said to probe the global chirality. Recent advances controlling the polarization and spatial structure of X-ray beams have led to novel spectroscopic techniques such as X-ray circular dichroism (XCD), which can exploit the localized nature of the X-ray electronic transitions. XCD is thus sensitive to local structures and the relevant chirality probed with it can be referred as local. Here, we use the racemization mechanism of the [12]Helicene as a model to assess the capabilities of OCD and XCD as probes of global and local chiralities. In conclusion, our simulations suggest that XCD is a reliable spectroscopic technique for probing the local chirality of molecules, suggesting the further development of this experimental technique.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Analysis of leading edge and trailing edge cover glass samples before and after treatment with advanced satellite contamination removal techniques

Two samples from Long Duration Exposure Facility (LDEF) experiment M0003-4 were analyzed for molecular and particulate contamination prior to and following treatment with advanced satellite contamination removal techniques (CO2 gas/solid jet spray and oxygen ion beam). The pre- and post-cleaning measurements and analyses are presented. The jet spray removed particulates in seconds. The low energy reactive oxygen ion beam removed 5,000 A of photo polymerized organic hydrocarbon contamination in less than 1 hour. Spectroscopic analytical techniques were applied to the analysis of cleaning efficiency including: Fourier transform infrared, Auger, x ray photoemissions, energy dispersive x ray, and ultraviolet/visible. The results of this work suggest that the contamination studied here was due to spacecraft self-contamination enhanced by atomic oxygen plasma dynamics and solar UV radiation. These results also suggest the efficacy for the jet spray and ion beam contamination control technologies for spacecraft optical surfaces.

Hotaling, S. P.↗

Interferometric spectropolarimetry - Alternate experimental methods.

Three alternate methods of obtaining spectra of the intensity and state of polarization of light are proposed. The methods make use of a two-beam amplitude division interferometer using the technique of Fourier spectroscopy. They do not require the presence of polarizers in the arms of the instrument. In one method a single analyzer is used in front of the detector with three successive orientations of its transmission axis azimuth. In another method, a (linear) polarizer assuming the same set of orientations is placed in the incident beam. A third method, a hybrid of the former two methods, makes use of both a polarizer and analyzer in the locations indicated. The first method permits the determination of all four Stokes parameters of polarization, whereas the other two methods cannot yield the ellipticity parameter. All methods require the recording of three interferograms. However, two interferograms can provide the intensity and degree of polarization in any of the methods described.

Fymat, A. L.↗

Improved quantitation of SIMS depth profile measurements of niobium via sample holder design improvements and characterization of grain orientation effects

The importance of SIMS analyses for “N-doped” impurity alloyed niobium and other surface-alloyed materials continues to increase. A major hurdle is the uncertainty of instrument calibration due to changes in sample height either from sample surface topography or from the sample holder itself. The CAMECA sample holder design allows for many types of samples to be analyzed. However, a drawback is that the holder faceplate can bend, contributing an uncertainty in the relative sensitivity factor (RSF) used to quantify the SIMS results. Here, we describe an improved sample holder having a reinforced faceplate, which prevents deflection and reduces uncertainty. Simulations show that the new design significantly reduces deflection from 10 μm to 5 nm. Sample measurements show a reduction of RSF uncertainty from this source from 4.1% to 0.95%. Grain orientation has long been suspected to affect RSF measurement as well. A bicrystal implant standard, consisting of randomly oriented and [001] grains, was successively rotated 15° between analyses. It was observed that 20% of the analyses performed on the randomly oriented grain exhibited anomalously high RSF values as well as slow sputter rates. These features were associated with the changing grain normal orientation with respect to the primary Cs + beam. The grain orientation associated with the rise in RSF was simulated and determined to be the [101] crystallographic plane, thus indicating that ion channeling was responsible for the significantly increased RSF. Focused ion beam analysis confirmed slower sputter rates for the cardinal crystallographic orientations, indicating that ion channeling occurred for each.

43 PARTICLE ACCELERATORS↗

Correlative electron and ion beam analysis of the electrochemical performances of LiV 3 O 8 cathode films as a function of microstructures

Degradation mechanisms in LiV 3 O 8 cathode films (~500 nm) with different initial microstructures i.e., globular nanocrystals in amorphous matrix and needle-like nanocrystals, synthesized by annealing the cathodes at 150 °C and 300 °C for 6 h are studied by Transmission Electron Microscopy (TEM) and Auger Electron Spectroscopy (AES). In addition, a unique in-situ combination of TEM and Secondary Ion Mass Spectrometry (SIMS) imaging techniques, namely Parallel Ion and Electron beam Spectrometry (PIES) is carried out to measure the 3D distribution of V and Li with nanoscale resolution. These characterization studies focus on correlating the pre- and post-cycling microstructure to observed electrochemical performance. The LiV 3 O 8 cathode film with needle-like nanocrystals (300 °C) shows a higher initial capacity but it degrades rapidly compared to the film with globular nanocrystals embedded in amorphous matrix (150 °C). We observed that LiV 3 O 8 films with needle-like nanocrystals are more susceptible to cathode decohesion and vanadium dissolution than the films with globular nanocrystals embedded in amorphous matrix, explaining the differences in their electrochemical performance. The findings from this study have relevance to the development of thin film electrode microstructures for high capacity and cyclic stability.

25 ENERGY STORAGE↗

Megahertz-rate shock-wave distortion cancellation via phase conjugate digital in-line holography

Abstract Holography is a powerful tool for three-dimensional imaging. However, in explosive, supersonic, hypersonic, cavitating, or ionizing environments, shock-waves and density gradients impart phase distortions that obscure objects in the field-of-view. Capturing time-resolved information in these environments also requires ultra-high-speed acquisition. To reduce phase distortions and increase imaging rates, we introduce an ultra-high-speed phase conjugate digital in-line holography (PCDIH) technique. In this concept, a coherent beam passes through the shock-wave distortion, reflects off a phase conjugate mirror, and propagates back through the shock-wave, thereby minimizing imaging distortions from phase delays. By implementing the method using a pulse-burst laser setup at up to 5 million-frames-per-second, time-resolved holograms of ultra-fast events are now possible. This technique is applied for holographic imaging through laser-spark plasma-generated shock-waves and to enable three-dimensional tracking of explosively generated hypersonic fragments. Simulations further advance our understanding of physical processes and experiments demonstrate ultra-high-speed PCDIH techniques for capturing dynamics.

Science & Technology - Other Topics↗

Manipulation of the orbital angular momentum of soft X-ray beams by consecutive diffractive optics

Production and manipulation of orbital angular momentum (OAM) of coherent soft X-ray beams is demonstrated utilizing consecutive diffractive optics. OAM addition is observed upon passing the beam through consecutive fork gratings. Here, the OAM of the beam was found to be decoupled from its spin angular momentum (SAM). Practical implementation of angular momentum control by consecutive devices in the X-ray regime opens new experimental opportunities, such as direct measurement of the beam’s OAM without resorting to phase-sensitive techniques, including holography. OAM analyzers utilizing fork gratings can be used to characterize the beams produced by synchrotron and free electron lasers sources; they can also be used in scattering experiments.

36 MATERIALS SCIENCE↗

Study of SEM induced current and voltage contrast modes to assess semiconductor reliability

The purpose of the scanning electron microscopy study was to review the failure history of existing integrated circuit technologies to identify predominant failure mechanisms, and to evaluate the feasibility of their detection using SEM application techniques. The study investigated the effects of E-beam irradiation damage and contamination deposition rates; developed the necessary methods for applying the techniques to the detection of latent defects and weaknesses in integrated circuits; and made recommendations for applying the techniques.

Beall, J. R.↗