Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “balance”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 847 records · Page 47

Evaluating Methods for Measuring Grid Frequency in Low-Inertia Power Systems: Preprint

Accurate measurement of grid frequency is a critical component of reliable grid control. Traditionally, methods such as phase locked loops (PLLs) and discrete Fourier transforms (DFTs) have been used in inverters and phasor measurement units (PMUs) to measure frequency. However, as the percentage of inverter-based resources (IBRs) such as solar and wind has increased, these conventional frequency measurement methods are proving unable to guarantee reliable control in some cases. One challenge is measuring frequency during transient events, where there is a disruption in the steady state sinusoidal voltage. During these events, the underlying frequency of the grid may barely change, but measurement methods report a large spike in frequency due to the disrupted waveform. New methods must balance between suppressing spikes in frequency during faults, and providing fast, accurate, measurements in all other grid operation conditions, especially during events with high rate-of-change-of frequency (ROCOF), which are more prevalent in high-IBR power systems. This paper first surveys frequency measurement methods that have been proposed to reduce measurement errors during transient events. Then, both conventional and more novel frequency measurement methods are tested against an IEEE standard and industry recommendations, and their performance is evaluated for events simulated in PSCAD. Results quantify the trade-offs in performance during different grid conditions and lead to suggestions for the most appropriate frequency and ROCOF measurement methods for low inertia grids.

frequency↗

Battery Degradation Modeling in Hybrid Power Plants: An Island System Unit Commitment Study: Preprint

As hybrid power plants (HPPs), such as photovoltaic (PV) and battery combinations, become increasingly important in power systems with high renewable energy penetration to address PV variability and ensure grid stability. This paper focuses on the urgent need to model the coordination between PV and battery systems in HPPs while accounting for battery degradation. We present a generation scheduling model that explicitly incorporates PV-battery hybridization in the unit commitment problem. Moreover, the cost function of the HPP scheduling problem endogenously considers battery degradation with adjustable weights to strike a balance between minimizing production costs and prolonging battery life, particularly when providing energy arbitrage and ancillary services. Using a realistic island system simulation, we demonstrate that accounting for battery degradation in the scheduling problem can significantly extend battery life with only minor additional production costs.

battery degradation↗

Impact of Detailed Parameter Modeling of Open-Cycle Gas Turbines on Production Cost Simulation: Preprint

Flexible resources are increasingly important as variable renewable energy deployment in the power system increases. Although many systems are transitioning away from fossil fuels, open-cycle gas turbines are likely to play an important balancing role for some time, thus requiring accurate modeling of their operational parameters. This paper explores the impact of detailed representation of three operational parameters - start- up costs, run-up rates, and forced outage rates - in the production cost model of a system as it adopts higher levels of wind and solar. Using PLEXOS simulations of the NREL-118 bus test system, the study examines how more detailed parameter modeling affects outcomes such as the number of start-ups and shutdowns, ramping and total generation costs for open-cycle gas turbines, as renewable energy levels increase. The results suggest the value of detailed parameter modeling and continued research on combustion turbines' ability to provide flexibility.

economic dispatch↗

Oscillatory Power Control and Consensus in Unbalanced Networks Using Grid Forming Inverters

In this paper, a state-space nonlinear control previously designed for balanced operation of grid-forming (GFM) inverters is extended to unbalanced operations. Unbalanced voltages and currents are analyzed, and their time-varying direct, quadrature, and zero components are parameterized in terms of six constant parameters. These parameters provide primary control design choices for not only an inverter’s terminal voltage but also its injections of both real and oscillatory power. It is shown that the proposed GFM control can precisely achieve a desired balanced terminal voltage under unbalanced loads. It is also shown that, by allowing the terminal voltage to be slightly unbalanced, oscillatory power can be adaptively minimized. Lastly, it is illustrated that oscillatory power can also be shared among multiple GFM inverters. Case studies and their simulations demonstrate that the proposed GFM control is effective in meeting the aforementioned objectives.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Secondary Frequency Control for Reconfigurable Interconnecting Microgrids

Microgrids and microgrid technologies offer an operations and control framework for realizing the needed aggregation of a growing share of distributed energy resources. As the number of microgrids increases, so will the incentive to interconnect them, leading to a combinatorial growth of potential operating states. At the same time, their growing complexity nudges interconnected microgrids conceptually closer to balancing authorities in the bulk power system. This paper focuses on secondary frequency control and leverages the conceptual similarity between balancing authorities and interconnected microgrids to adopt an automatic generation control design with some adaptations. Frequency control and restoration is demonstrated via several use-cases with switching and reconfiguration events.

Schweitzer, Eran↗

Highly Reliable Multi-Port Smart Inverter Modules for PV-Based Energy Systems

Generally, large electrolytic capacitors (E-caps) are required to decouple the double-line frequency power fluctuation inherent in all single-phase dc-ac or ac-dc converters. These E-caps pose the weak link in the photovoltaic (PV) inverter because they have poor reliability as a result of short life expectancy and higher equivalent series resistance (ESR) which leads to lower system efficiency. In this paper, multiport smart dual-inverter modules are proposed for residential PV inverter systems with balanced outputs to eliminate the requirement of large decoupling capacitors, thus leading to more reliable and highly efficient inverter modules. The balanced dual outputs are controlled in phase quadrature such that the double frequency current is completely eliminated. One phase supports the standalone residential loads, and the other phase interfaces with the grid, which is synchronized to the utility grid. Also, the proposed modular configuration is scalable to accommodate higher power rating by stacking and paralleling multiple modules. Simulation results for the dual-inverter modules rated for 1 kW each are presented to validate the proposed concept. Experimental results from a controller hardware-in-the-loop (CHIL) platform also verify its feasibility.

14 SOLAR ENERGY↗

Heuristic Dispatch Based on Price Signals for Behind-the-Meter PV-Battery Systems in the System Advisor Model

The economic potential of a behind-the-meter (BTM) PV-battery system depends greatly on how the battery is dispatched. Different utility rates, system sizes, generation and load profiles can all require different dispatch strategies. This paper presents price signals dispatch, a new algorithm for automated economic dispatch of BTM PV-battery systems, which utilizes 24-hour PV and load forecasts, degradation data, and utility rates. The algorithm is integrated with the System Advisor Model (SAM) tool and is tested with a nonlinear generic electrochemical battery model. Price signals dispatch outperforms SAM's existing algorithms in cases requiring a balance between demand charge management and energy arbitrage, and in cases where battery degradation imposes a significant cost.

batteries↗

Performance Evaluation of an Advanced Distributed Energy Resource Management Algorithm

This paper presents performance evaluation of a new distributed energy resource management system (DERMS) algorithm via an advanced hardware-in-the-loop (HIL) platform. The HIL platform provides realistic testing in a laboratory environment, including the accurate modeling of sub-transmission and distribution networks, the DERMS software controller, and 84 power hardware solar photovoltaic (PV) inverters, standard communication protocols, and a capacitor bank controller. The DERMS algorithm is also called, Grid-Optimization of Solar (GO-Solar) platform which includes predictive state estimation (PSE) and online multiple objective optimization (OMOO) to dispatch the legacy devices and distributed energy resources (e.g., PV). The voltage regulation performance is evaluated under three scenarios, volt-var smart inverter (baseline), and DERMS control for 100% and 30% of PV. The results show that controlling 30% of PV systems with the GO-Solar platform may provide the best balance of control performance and implementation cost.

distributed energy resource management system (DER↗

Heat Treatment Studies of Nb3Sn Wires for Superconducting Planar Undulators

A project aiming to fabricate a full-length 2.8-m long Nb 3Sn superconducting undulator for the storage ring was started last year at the ANL APS. These Nb 3 Sn undulators operate at a maximum magnetic field on the conductor of about 5 T. To address instabilities at this field, two Nb 3 Sn wires with small subelement size were used. Specifically, Restacked Rod Processed wires of 0.6mmin diameter and with 144 and 150 superconducting subelements respectively, over 169 total. The equivalent subelement diameter, DS, of thesewires is35 mu m. At these smallDS values, the critical current density is known to deteriorate, and the Residual Resistivity Ratio is very sensitive to heat treatment. A delicate balance has therefore to be found to obtain parameters within operation specifications. In this paper we showperformance results from different heat treatments.

critical current density↗

FPDeep: Scalable Acceleration of CNN Training on Deeply-Pipelined FPGA Clusters

In this paper, we propose a framework called FPDeep, which uses a hybrid of model and layer paral- lelism to configure distributed reconfigurable clusters to train DNNs. This approach has numerous benefits. First, the design does not suffer from batch size growth. Second, novel workload and weight partitioning leads to balanced loads of both among nodes. And third, the entire system is fine-grained pipeline. This leads to high parallelism and utilization and also minimizes the time features need to be cached while waiting for back-propagation.

Wang, Tianqi↗

Optimal Power Management for Large-Scale Battery Energy Storage Systems via Bayesian Inference

Large-scale battery energy storage systems (BESS) have found ever-increasing use across industry and society to accelerate clean energy transition and improve energy supply reliability and resilience. However, their optimal power management poses significant challenges: the underlying high-dimensional nonlinear nonconvex optimization lacks computational tractability in real-world implementation, and the uncertainty of the exogenous power demand makes exact optimization difficult. This paper presents a new solution framework to address these bottlenecks. The solution pivots on introducing power-sharing ratios to specify each cell’s power quota from the output power demand. To find the optimal power-sharing ratios, we formulate a nonlinear model predictive control (NMPC) problem to achieve power-loss-minimizing BESS operation while complying with safety, cell balancing, and power supply-demand constraints. We then propose a parameterized control policy for the power-sharing ratios, which utilizes only three parameters, to reduce the computational demand in solving the NMPC problem. This policy parameterization allows us to translate the NMPC problem into a Bayesian inference problem for the sake of 1) computational tractability, and 2) overcoming the nonconvexity of the optimization problem. We leverage the ensemble Kalman inversion technique to solve the parameter estimation problem. Concurrently, a low-level control loop is developed to seamlessly integrate our proposed approach with the BESS to ensure practical implementation. This low-level controller receives the optimal power-sharing ratios, generates output power references for the cells, and maintains a balance between power supply and demand despite uncertainty in output power. We conduct extensive simulations and experiments on a 20-cell prototype to validate the proposed approach.

Battery energy storage systems (BESSs)↗

TPCPF: Three-Phase Continuation Power Flow Tool for Voltage Stability Assessment of Distribution Networks With Distributed Energy Resources

This article presents a three-phase unbalanced continuation power flow algorithm for voltage stability assessment of distribution systems with high penetration of distributed energy resources (DERs). Analyzing distribution system voltage stability with DER will allow high penetration of renewable energy necessary for the sustainability goals. The developed algorithm can analyze voltage stability for both the meshed and radial systems and the balanced and unbalanced three-phase distribution systems. The developed tool allows the voltage stability analysis to facilitate the planning, operation, control, and distribution system management. The impact of DER on the voltage stability of several test cases has been analyzed considering constant power (P Q) and regulated-voltage (P V ) modes of operation for DER units. Moreover, different voltage stability case studies are presented to demonstrate the impact of unbalance, load increment, and network topology on the maximum loading capacity. Finally, results using the IEEE 13-node feeder, the 18-bus balanced shipboard system, the 13-node CIGRE benchmark system, and the 136-bus redial distribution feeder demonstrate that the developed continuation power flow tool can efficiently perform voltage stability analysis for active distribution systems.

42 ENGINEERING↗

Virtual Self-Excited Induction Generator-Based Grid-Forming Inverter Control for Robust Voltage Regulation Under Nonideal Loading

This paper presents a generator-inspired control methodology for grid-forming (GFM) inverters that deliberately emulates a self-excited induction generator so that the inverter can hold its voltage and frequency under difficult loading and severe terminal disturbances across wide voltage and frequency ranges. The design integrates a Lyapunov energy function-based inner loop to provide high bandwidth and strong disturbance rejection, and it complements this with a passivity-based argument that furnishes a coherent large-signal stability guarantee beyond small-signal limits. Analytical insights are developed via the Krylov-Bogoliubov-Mitropolsky averaging method, which reveals an intrinsic resistive droop characteristic; these closed-form relations both explain the observed dynamics and yield simple, decentralized tuning rules. The methodology is validated on a controller-hardware-in-the-loop platform and exercised in real time across balanced, unbalanced, and nonlinear loads, as well as during parallel operation. Across these scenarios, the inverter maintains balanced three-phase voltages, limits harmonic content, settles quickly with well-damped transients, and remains resilient when multiple units operate in parallel. The contributions are a self-excited-machine-inspired GFM controller with enhanced dynamic performance and robustness, a single stability rationale grounded in passivity, closed-form expressions that guide tuning, and comprehensive hardware-in-the-loop validations demonstrating effectiveness and superiority under challenging operating conditions.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Machine Learning-Assisted Stability Boundary Determination of Multiport Autonomous Reconfigurable Solar Power Plants

The multiport autonomous reconfigurable solar (MARS) power plant is a promising solution to integrate renewable resources and energy storage systems into the alternating current (ac) power grid and an high-voltage direct current (HVdc) link. In the MARS system, various input power sources are connected to the individual submodules (SMs) through direct current (dc)–dc converters. However, the presence of external power sources can result in unbalanced capacitor voltages of SMs, thereby violating stability constraints under multiple/diverse operating conditions. This article aims to address the gap by accurately determining the stability boundary of the MARS system. As such, a novel machine learning (ML)-assisted energy balancing control (EBC) criterion is proposed. Further, in conjunction with a refined EBC, this approach ensures balanced capacitor voltages across various types of SMs, significantly enhancing the overall system efficiency. The proposed EBC criterion effectively controls EBC activation and deactivation, achieving remarkable accuracy. Both power systems computer aided design (PSCAD)/electromagnetic transients including direct current (EMTDC) simulations and control hardware-in-the-loop (cHIL) tests are conducted to validate the feasibility and efficiency of the proposed method. By combining the EBC and ML-assisted EBC criterion, efficient energy management is achieved for systems featuring multiple input power sources, such as MARS. This approach enables the system to fully exploit its potential across an expanded operational range while upholding high-efficiency standards.

14 SOLAR ENERGY↗

A Single Passive Gate-Driver for Series Connected Power Devices in DC Circuit Breaker Applications

This letter proposes a novel single passive gate driver solution based on passive devices to control series-connected power semiconductor devices for dc circuit breaker (DCCB) applications. The transient suppression devices (e.g., metal oxide varistors) are utilized to achieve natural voltage balancing among the series devices, while providing the discharge path of the gate capacitor of the upper devices. Here, the proposed method is very simple, cost effective and more compact compared with conventional voltage balancing method-based DCCBs. Besides, gate voltage oscillation during the voltage recovery process is mitigated by the addition of an extra gate capacitor. Simulation and experimental results are provided to verify the effectiveness of proposed method.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Formulation of Three-Phase State Estimation Problem Using a Virtual Reference

State Estimation (SE) is the backbone of modern Energy Management System (EMS) due its capability of processing real time measurements and provide reliable information to system operators. Since its introduction to power systems in the 70’s, SE has been widely used in transmission networks. Distribution grids on the other hand lack sufficient number of real time measurements, and for that reason SE has not been widely implemented on these systems. The recent increase in the number of renewable energy sources connected to the grid at lower voltage levels, the advent of Distribution Automation (DA) and Smart Grids necessitate closer monitoring of distribution networks and thus forcing utilities to upgrade their operations and deploy Advanced Distribution Management Sytems (ADMS). Therefore, Distribution System State Estimation (DSE) is paramount to provide real time monitoring of active distribution grids. This papers investigates the formulation of the three-phase distribution state estimation where in the most general case, none of the system buses may have balanced three phase voltages. In such a case, the choice and definition of the slack bus need to be revisited. Most of the existing work arbitrarily assign the root bus of the distribution feeder as the balanced three-phase reference which may not be realistic for today’s active distribution systems. This paper addresses this shortcoming of the existing SE formulations by introducing a virtual reference bus. Here, the proposed approach is effectively validated by simulations carried out on distribution test systems.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Energy-Storage Modeling: State-of-the-Art and Future Research Directions

Given its physical characteristics and the range of services that it can provide, energy storage raises unique modeling challenges. This paper summarizes capabilities that operational, planning, and resource-adequacy models that include energy storage should have and surveys gaps in extant models. Existing models that represent energy storage differ in fidelity of representing the balance of the power system and energy-storage applications. Modeling results are sensitive to these differences. The importance of capturing chronology can raise challenges in energy-storage modeling. Some models ‘decouple’ individual operating periods from one another, allowing for natural decomposition and rendering the models relatively computationally tractable. Energy storage complicates such a modeling approach. Improving the representation of the balance of the system can have major effects in capturing energy-storage costs and benefits.

25 ENERGY STORAGE↗

Automated Control of Transactive HVACs in Energy Distribution Systems

Heating, Ventilation, and Air Conditioning (HVAC) systems contribute significantly to a building’s energy consumption. In the recent years, there is an increased interest in developing transactive approaches which could enable automated and flexible scheduling of HVAC systems based on the customer demand and the electricity prices decided by the suppliers. Flexible and automated scheduling of the HVAC systems make it a prime source for participation in residential demand response or transactive energy systems. Therefore, it is of significant interest to identify an optimal strategy to control the HVAC systems. Here, reducing the energy cost while keeping the comfort level acceptable to the users, we argue that such a control strategy should consider both the energy cost and user comfort simultaneously. Accordingly, we develop the control strategy through the solution of an optimization problem that balances between the energy cost and consumer’s dissatisfaction. This optimization enables us to solve a decision-making problem through first price prediction and then choosing HVAC temperature settings throughout the day based on the predicted price, history of the price and HVAC settings, and outside temperature. More specifically, we formulate the control design as a Markov decision process (MDP) using deep neural networks and use Deep Deterministic Policy Gradients (DDPG)-based deep reinforcement learning algorithm to find the optimal control strategy for HVAC systems that balances between electricity cost and user comfort.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗