Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “acceptance sampling”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 847 records · Page 47

Some physiochemical and heavy metal concentration in surface water streams of Tutuka in the Kenyasi mining catchment area

This research was conducted in the Akantansu stream of Tutuka in Kenyasi in the Brong Ahafo Region of Ghana in the months of October and November 2010 and January 2011. The major objectives of the study were to measure levels of pH, BOD (biochemical oxygen demand), lead, chromium, and arsenic in the Akantansu stream of Tutuka and to find ways that the community could ensure safe water use. To achieve the objectives of the study, sampling was done over a period of three months and data was collected and analyzed into graphs and ANOVA tables. The research revealed that the levels of arsenic and BOD were high as compared to the standards of WHO and EPA. If the people of Tutuka continue to use the stream, they may experience negative health effects (e.g., nausea, vomiting, diarrhea, etc.). The level of pH, chromium and lead was acceptable as compared to the standard of WHO and EPA. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Extraction, Scrub, and Strip Test Results for the Second Solvent Lot Qualification Sample for the Salt Waste Processing Facility

An Extraction, Scrub, and Strip (ESS) test was performed on the qualification sample from the second lot of Caustic-Side Solvent Extraction (CSSX) solvent for the Salt Waste Processing Facility (SWPF). Testing used simulated salt solution to determine cesium distribution ratios (D( Cs )), and cesium concentration in the strip effluent (SE) and decontaminated salt solution (DSS) streams. This data will be used by Parsons to help determine if the solvent is qualified for use at the SWPF. The ESS test showed acceptable performance of the solvent for extraction, scrub, and strip operations. The extraction D( Cs ) measured 14.4, exceeding the required value of 8. This value is consistent with results from previous ESS tests using similar solvent formulations. Similarly, scrub and strip cesium distribution ratios fell within acceptable ranges.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Sampling for Confidence: Guidance for Evaluating the Quality of Canister Sampling Plans

There is a need for an inspection frequency that demonstrates reasonable assurance that the confinement function of dual-purpose-canisters (DPCs) is maintained as these DPCs are returned to storage service following transportation. The DPCs contain spent fuel from shutdown reactor sites. The currently-proposed 100% DPC inspection frequency is overly conservative and unnecessary to demonstrate reasonable assurance that the confinement function of all DPCs is maintained for return to storage service. Testing all DPCs does not appropriately reflect the very low risk of leakage (i.e., low probability based on design and low consequences based on analysis). Currently, there are 1066 DPCs forecast to be loaded at reactor sites which either are shutdown or plan to cease operations by 2025. These DPCs may be transported by rail in sets of 3 to 5 DPCs per shipment. Assuming each rail consist originates at a single reactor site, an alternative proposal to test one canister/consist/site would result in 356 to 214 canisters, respectively, being tested given the population of 1,066 canisters This Savannah River National Laboratory (SRNL) report outlines statistically-based, random sampling plans that provide guidance on the number of samples of these canisters that are needed to establish bounds on the quality of the outcome of such sampling. The quality of each proposed sampling plan is expressed in the form of a statement that the number of undetected, unacceptable canisters in the population is less than some number, call it D, at a high level of confidence. In addition, evaluations using a similar approach for random sampling at the proposed levels of 214 and 356 canisters are provided. This is a technical report that does not take into account the contractual limitations under the Standard Contract for Disposal of Spent Nuclear Fuel and/or High-Level Radioactive Waste (Standard Contract) (10 CFR Part 961). Under the provisions of the Standard Contract, DOE does not consider spent nuclear fuel in multi-assembly canisters to be an acceptable waste form, absent a mutually agreed upon contract amendment. To the extent discussions or recommendations in this report conflict with the provisions of the Standard Contract, the Standard Contract provisions prevail.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Cesium Removal from 5.5 and 7.0 M Na AP-105 Using Crystalline Silicotitanate

The Tank Side Cesium Removal (TSCR) system, currently operational by Washington River Protection Solutions LLC (WRPS), prepares initial low-activity Hanford waste tank supernate feeds for the Hanford Waste Treatment and Immobilization Plant (WTP) Low-Activity Waste (LAW) Facility. In addition to entrained solids removal from the supernate, the primary goal of TSCR is to remove cesium-137 ( 137 Cs) by ion exchange, allowing contact handling of the liquid effluent product at the WTP as governed by a waste acceptance criterion (WAC). Specific to 137 Cs, this requirement is < 3.18E-5 Ci 137 Cs/mole of Na. Crystalline silicotitanate (CST) ion exchange media, manufactured by Honeywell UOP, LLC (product IONSIVTM R9140-B), has been selected as the ion exchange media for TSCR. CST is a non-elutable inorganic material that has demonstrated robust chemical, physical, and radiation tolerance while maintaining functionality. However, testing to date on actual tank waste samples has been limited to Na concentrations between 5 and 6 M Na (Fiskum et al. 2019a, 2021b and Westesen et al. 2021a, 2021b, 2022) while actual tank conditions can reach upwards of 9 M Na. Testing with feed from Hanford tank AP-105 incorporated testing at both 5.5 and 7 M Na in order to evaluate the impact of Na concentration on volume of waste processed before reaching the WAC. A 6-L volume of 5.5 M Na AP-105 and an 8-volume of 7 M Na AP-105 was processed through the Radioactive Waste Test Platform system, established at Pacific Northwest National Laboratory to support small-scale waste qualification efforts. The columns consisted of 6- to 9-mL CST beds (CST Lot 2002009604, sieved to screen out >30-mesh particles) placed in 1.5-cm-inner-diameter columns. Feed was processed at 1.9 bed volumes (BV) per hour; the flowrate, in terms of contact time with the CST bed, matched the expected flowrate at TSCR. Table S.1 and Figure S.1 summarize the measured AP-105 Cs load performance for each feed condition.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Remediation Residential Properties Contaminated with LLRW as Part of the Port Hope Area Initiative - The Importance of Effective Community Consultation - 18591

The Port Hope Area Initiative (PHAI) is a community-based solution for the long-term management of historic low level radioactive waste (LLRW) resulting from 60 years of uranium and radium processing operations in the urban setting of Port Hope, Ontario. The Eldorado refinery, on the shores of Lake Ontario, began refining radium-226 from pitchblende ore, later transitioning to the refining of uranium ore. Process residues were deposited at the Welcome Waste Management Facility in the Municipality of Port Hope until the mid-1950's switching to the Port Granby Waste Management Facility (PGWMF), which continued to accept waste until the late 1980's. Within the community of Port Hope, surveys are being conducted at approximately 4800 individual properties to identify the presence of LLRW resulting from fugitive emissions from the refinery and/or the use of refinery residue as construction backfill within the community. Identification of the presence of LLRW is based on multiple lines of evidence including reviews of historical information, gamma radiation surveys and physical sampling of soil for the presence of four signature contaminants. Of the 4800 properties being surveyed, it is expected that approximately 10% will contain some degree of LLRW requiring physical remediation. Many of the residences requiring remediation will require extensive soil removal, removal and restoration of outbuildings, fences and other structures, and the removal of mature trees, hedges and decorative gardens. For the property owners involved this phase represents the final and most intrusive aspect of the program. As such, the remedial designs must be sensitive to the needs of the community and individual property owners taking into consideration factors such as the need to minimize the disturbance to the neighborhood; maintaining geotechnical and structural stability of homes during excavations; removal and restoration of outbuildings affected by LLRW; removal and replacement of landscaping features (decks, fences, pools etc) and mature trees; radiation protection during earthworks; control of dust and noise; and maintaining safe access by residents. As Community satisfaction is a key metric for the success of the project, constant and effective communication at all stages of the project is necessary to ensure the residents understand the nature and extent of work to be undertaken; any and all inconveniences they can expect during the work; contingencies to deal with those inconveniences (e.g. parking, garbage collection etc); measures to protect their health and safety; scheduling; and what their property will look like at the completion of works. This paper provides an overview of the residential remediation program in Port Hope and describes the consultation efforts with property owners that are integral to the development of final designs. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Establishment of time‐resolved fluoroimmunoassay of IgG4 based on magnetic microspheres

Abstract Background The abnormal increase in serum IgG4 level is an important clinical symptom of IgG4‐related disease (IgG4‐RD), and the detection of serum IgG4 level is a powerful tool for the diagnosis of IgG4‐RD. This study was conducted to establish a simple and rapid immunoassay for the determination of human serum IgG4 levels. Methods Based on the competition method, a novel immunoassay was established for the determination of human serum IgG4 using a combination of time‐resolved fluoroimmunoassay (TRFIA) and magnetic microspheres. IgG4 was coupled with magnetic microspheres and competed with IgG4 in the samples to bind the Eu 3+ ‐labeled anti‐IgG4 antibody. The immunocomplex was separated and washed in a magnetic field, and the fluorescence counts were measured according to the number of dissociated europium ions. Results The analytical sensitivity of IgG4‐TRFIA based on magnetic microspheres was 0.006 g/L, and the detection range was 0.006–20 g/L under optimal conditions. The precision, recovery, and specificity of this immunoassay were demonstrated to be acceptable. The clinical application of IgG4‐TRFIA based on magnetic microspheres was evaluated and compared with that of immunonephelometry. The results showed that the two detection methods had a good correlation, with a correlation coefficient of .9871. Conclusion IgG4‐TRFIA based on magnetic microspheres has the advantages of high sensitivity, wide detection range, and short analysis time and has the potential to become a useful tool for the diagnosis of IgG4‐RD.

Wu, Qingqing↗

Role of Peroxiredoxin I in Rectal Cancer and Related to p53 Status

Background: Neoadjuvant chemoradiotherapy is widely accepted for the treatment of localized rectal cancer. Although peroxiredoxin I (PrxI) and p53 have been implicated in carcinogenesis and cancer treatment, the role of PrxI and its interaction with p53 in the prognosis and treatment response of rectal cancer remain relatively unstudied. Methods and Materials: In the present study, we examined the levels of PrxI and p53 in rectal cancer patients using membrane arrays and compared them with normal population samples. To demonstrate the biologic changes after manipulation of PrxI expression, we established stable transfectants of HCT-116 (wild-type p53) and HT-29 (mutant p53) cells with a PrxI silencing vector. The predictive capacities of PrxI and p53 were also assessed by relating the immunohistochemical staining of a retrospective series of rectal cancer cases to the clinical outcome. Results: The membrane array and immunochemical staining data showed that PrxI, but not p53, was significantly associated with the tumor burden. Our immunochemistry findings further indicated that PrxI positivity was linked to a poor response to neoadjuvant therapy and worse survival. In cellular and animal experiments, the inhibition of PrxI significantly decreased tumor growth and sensitized the tumor to irradiation, as indicated by a lower capacity to scavenge reactive oxygen species and more extensive DNA damage. The p53 status might have contributed to the difference between HCT-116 and HT-29 after knockdown of PrxI. Conclusion: According to our data, the level of PrxI combined with the p53 status is relevant to the prognosis and the treatment response. We suggested that PrxI might be a new biomarker for rectal cancer.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

VALIDATION OF ANALYTICAL METHODS AND INSTRUMENTATION FOR BERYLLIUM MEASUREMENT: REVIEW AND SUMMARY OF AVAILABLE GUIDES, PROCEDURES, AND PROTOCOLS

Method validation is the process of evaluating whether an analytical method is acceptable for its intended purpose. For pharmaceutical methods, guidelines from the United States Pharmacopeia (USP), International Conference on Harmonisation (ICH), and the United States Food and Drug Administration (USFDA) provide a framework for performing such valications. In general, methods for regulatory compliance must include studies on specificity, linearity, accuracy, precision, range, detection limit, quantitation limit, and robustness. Elements of these guidelines are readily adapted to the issue of validation for beryllium sampling and analysis. This document provides a listing of available sources which can be used to validate analytical methods and/or instrumentation for beryllium determination. A literature review was conducted of available standard methods and publications used for method validation and/or quality control. A comprehensive listing of the articles, papers and books reviewed is given in the Appendix. Available validation documents and guides are listed therein; each has a brief description of application and use. In the referenced sources, there are varying approches to validation and varying descriptions of the valication process at different stages in method development. This discussion focuses on valication and verification of fully developed methods and instrumentation that have been offered up for use or approval by other laboratories or official consensus bodies such as ASTM International, the International Standards Organization (ISO) and the Association of Official Analytical Chemists (AOAC). This review was conducted as part of a collaborative effort to investigate and improve the state of validation for measuring beryllium in the workplace and the environment. Documents and publications from the United States and Europe are included. Unless otherwise specified, all referenced documents were published in English.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Hadron spectroscopy of pseudoscalar and vector meson photoproduction using linearly polarised photons at CLAS

The field of hadron spectroscopy is informed by experiments which study excited states of the nucleon by detecting the decay products following excitation with a hadronic, leptonic or electromagnetic probe. Experiments using a polarised beam of photons provide an important contribution to the world data. This thesis describes the analysis of data from one such experiment, the CEBAF Large Acceptance Spectrometer at Jefferson Laboratory, Virginia, USA. In the experiment, an incident beam of electrons passes through a diamond radiator producing a linearly polarised photon beam of energy from 1.1 to 2.1 GeV on a liquid hydrogen target. The analysis method and results for two reaction channels are presented. In the first analysis, the polarisation observables {?, P, T, Ox, Oz} for the reaction ??? p ? K0 S ?+ are extracted simultaneously using likelihood sampling with Markov-Chain Monte-Carlo. The results are presented as angular distributions (cos ?K0S) for bins in photon energy E? for a total of 21 bins. The values extracted for T , Ox and Oz are a first measurement of these quantities for this reaction and the beam asymmetry (?) measurement supplements the one previous measurement for this quantity and extends the energy range over which it has been extracted. The measurement of the recoil polarisation, P, is consistent with previous measurements. In a second analysis, the spin density matrix elements (SDMEs) for ? p ? p ? are extracted using similar analysis techniques. The results are presented as angular distributions (cos ?? ) for bins in photon energy E? for a total of 24 bins. This work is the first to extract all nine SDMEs for the full angular range of the ? meson production. A comparison is made to the predictions of the Vector Meson Dominance (VMD) model and the results provide evidence for contributing processes other than VMD, particularly at more backward angles of the ? meson production. The data also indicate non-helicity conserving process in both the s-channel and the t-channel. The results from the first analysis have been passed to the Juelich-Bonn theory group and the effect of including the new data within their dynamical coupled channel model is described. Several nucleon resonances are affected and the impact on the pole positions, widths and photon decay amplitudes of the affected resonances is described.

Clark, Louise↗

Hanford Waste Treatment Plant Effluent Management Facility Stack Effluent Monitoring: Sampling Probe Location Qualification Evaluation

The Hanford Tank Waste Treatment and Immobilization Plant Effluent Management Facility (EMF) stack monitor location was qualified using a combination of scale model stacks to mitigate the risk of identifying that the sampling location does not meet the qualification criteria on the full-scale stack. The LV-S1 scale model stack was used as a baseline, augmented by the LB-S1 and LV-S2 scale model stacks to address the Direct Feed Low Activity Waste Effluent Management Facility Vessel Vent Process (DVP) injection into the main Active Confinement Ventilation (ACV) system duct. As required by the American National Standards Institute/Health Physics Society (ANSI/HPS) N13.1-1999 standard, the scale model and its sampling locations were geometrically similar to the actual stack, and the Reynolds numbers for both the actual and model stacks were >10,000. An additional criterion is that the product of the hydraulic diameter and mean velocity (DV) of the full-scale stack must be between 1/6 DV and 6 DV of the scale model stack tests. The LV-S1, LB-S1, and LV-S2 scale model stack tests have met the criteria of the ANSI/HPS N13.1-1999 standard to demonstrate the stack sampling locations are well mixed. Verification tests of the EMF stack were performed at normal operating conditions. The minimum 1/6 DV value and the maximum 6 DV value from the scale model testing determine the range of stack flow rates for which the full-scale stack may be operated while remaining in compliance with the stack verification criterion. A practical range for the full-scale stack qualification uses the average DV through 6 DV from the scale model tests to compute the corresponding flow rates. Table S1 lists the operating flow rate along with the average and maximum qualified stack flow rate based on the LV-S1 scale model DV values. The operating flow is below the maximum qualified stack flow, which means that the scale model test results are acceptable for stack qualification. The remaining criteria for the stack verification to be considered valid involve the flow angle and velocity uniformity results. First, the flow angle at the full-scale stack must be ≤20°. Second, the velocity uniformity at the full-scale stack must be ≤20% coefficient of variance (COV). Finally, the velocity uniformity results for the actual and scale model stack tests must agree within 5% COV. These criteria were met through the full-scale stack test at the EMF. Flow angle results were <5°; all flow angle results were within the ≤20° criterion. The velocity uniformity results for each test condition ranged between 2.2% COV and 4.3% COV, all of which were within the range of the target % COV values from the scale model tests on the LV-S1, LB-S1, and LV S2 scale models. Based on these stack verification test results, the EMF filtered exhaust stack sampling location meets the qualification criteria provided in the ANSI/HPS N13.1-1999 standard for all planned fan operating configurations. This includes each combination of ACV fans with DVP exhausters. Further changes to the system configuration or operating conditions that are outside the qualified flow rates described in this report may require additional tests or analyses to determine compliance with the standard.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

A Decision-Relevant Factor-Fixing Framework: Application to Uncertainty Analysis of a High-Dimensional Water Quality Model

Factor Fixing (FF) is a common method for reducing the number of model parameters to lower computational cost. FF typically starts with distinguishing the insensitive parameters from the sensitive and pursues uncertainty quantification (UQ) on the resulting reduced-order model, fixing each insensitive parameter at a fixed value. There is a need, however, to expand such a common approach to consider the effects of decision choices in the FF-UQ procedure on metrics of interest. Therefore, to guide the use of FF and increase confidence in the resulting dimension-reduced model, we propose a new adaptive framework consisting of four principles: (a) re-parameterize the model first to reduce obvious non-identifiable parameter combinations, (b) focus on decision relevance especially with respect to errors in quantities of interest (QoI), (c) conduct adaptive evaluation and robustness assessment of errors in the QoI across FF choices as sample size increases, and (d) reconsider whether fixing is warranted. The framework is demonstrated on a spatially-distributed water quality model. The error in estimates of QoI caused by FF can be estimated using a Polynomial Chaos Expansion (PCE) surrogate model. Built with 70 model runs, the surrogate is computationally inexpensive to evaluate and can provide global sensitivity indices for free. For the selected catchment, just two factors may provide an acceptably accurate estimate of model uncertainty in the average annual load of Total Suspended Solids (TSS), suggesting that reducing the uncertainty in these two parameters is a priority for future work before undertaking further formal uncertainty quantification.

54 ENVIRONMENTAL SCIENCES↗

Urban mining by flash Joule heating

Abstract Precious metal recovery from electronic waste, termed urban mining, is important for a circular economy. Present methods for urban mining, mainly smelting and leaching, suffer from lengthy purification processes and negative environmental impacts. Here, a solvent-free and sustainable process by flash Joule heating is disclosed to recover precious metals and remove hazardous heavy metals in electronic waste within one second. The sample temperature ramps to ~3400 K in milliseconds by the ultrafast electrical thermal process. Such a high temperature enables the evaporative separation of precious metals from the supporting matrices, with the recovery yields >80% for Rh, Pd, Ag, and >60% for Au. The heavy metals in electronic waste, some of which are highly toxic including Cr, As, Cd, Hg, and Pb, are also removed, leaving a final waste with minimal metal content, acceptable even for agriculture soil levels. Urban mining by flash Joule heating would be 80× to 500× less energy consumptive than using traditional smelting furnaces for metal-component recovery and more environmentally friendly.

01 COAL, LIGNITE, AND PEAT↗

Characterization of the scintillation response of water-based liquid scintillator to alpha particles, and implications for particle identification

Next-generation large-scale neutrino detectors, from EOS, at the 1 t scale, to THEIA, at the 10 s-of-kt scale, will utilize differences in both the scintillation and Cherenkov light emission for different particle species to perform background rejection. This manuscript presents measurements of the scintillation light yield and emission time profile of water-based liquid scintillator samples in response to α radiation. These measurements are used as input to simulation models used to make predictions for future detectors. In particular, we present the timing-based particle identification achievable in generic water-based scintillator detectors at the 4 t, 1 kt, and 100 kt scales. We find that α/β discrimination improves with increasing scintillation concentration and we identify better than 80% α rejection for 90% β acceptance in 10% water-based liquid scintillator, at the 4 t scale.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Testing the Large-scale Environments of Cool-core and Non-cool-core Clusters with Clustering Bias

There are well-observed differences between cool-core (CC) and non-cool-core (NCC) clusters, but the origin of this distinction is still largely unknown. Competing theories can be divided into internal (inside-out), in which internal physical processes transform or maintain the NCC phase, and external (outside-in), in which the cluster type is determined by its initial conditions, which in turn leads to different formation histories (i.e., assembly bias). We propose a new method that uses the relative assembly bias of CC to NCC clusters, as determined via the two-point cluster-galaxy cross-correlation function (CCF), to test whether formation history plays a role in determining their nature. We apply our method to 48 ACCEPT clusters, which have well resolved central entropies, and cross-correlate with the SDSS-III/BOSS LOWZ galaxy catalog. We find that the relative bias of NCC over CC clusters is b = 1.42 ± 0.35 (1.6 σ different from unity). Our measurement is limited by the small number of clusters with core entropy information within the BOSS footprint, 14 CC and 34 NCC clusters. Future compilations of X-ray cluster samples, combined with deep all-sky redshift surveys, will be able to better constrain the relative assembly bias of CC and NCC clusters and determine the origin of the bimodality.

79 ASTRONOMY AND ASTROPHYSICS↗

Accurate determination of Curium and Californium isotopic ratios by inductively coupled plasma quadrupole mass spectrometry (ICP-QMS) in 248Cm samples for transmutation studies

The French Atomic Energy Commission has carried out several experiments including the mini-INCA (INcineration of Actinides) project for the study of minor-actinide transmutation processes in high intensity thermal neutron fluxes, in view of proposing solutions to reduce the radiotoxicity of long-lived nuclear wastes. In this context, a Cm sample enriched in {sup 248}Cm ({approx}97 %) was irradiated in thermal neutron flux at the High Flux Reactor (HFR) of the Laue-Langevin Institute (ILL). This work describes a quadrupole ICP-MS (ICP-QMS) analytical procedure for precise and accurate isotopic composition determination of Cm before sample irradiation and of Cm and Cf after sample irradiation. The factors that affect the accuracy and reproducibility of isotopic ratio measurements by ICP-QMS, such as peak centre correction, detector dead time, mass bias, abundance sensitivity and hydrides formation, instrumental background, and memory blank were carefully evaluated and corrected. Uncertainties of the isotopic ratios, taking into account internal precision of isotope ratio measurements, peak tailing, and hydrides formations ranged from 0.3% to 1.3%. This uncertainties range is quite acceptable for the nuclear data to be used in transmutation studies.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Data and scripts associated with “Non-random processes impacting organic matter chemistry are maximized in mid-order streams”

NOTE: The manuscript associated with this data package is currently in review. The data may be revised based on reviewer feedback. Upon manuscript acceptance, this data package will be updated with the final dataset and additional metadata. This data package is associated with the publication “Non-random processes impacting organic matter chemistry are maximized in mid-order streams” submitted to Limnology and Oceanography (L&O) by Danczak et al. (in review). This package contains data and scripts used to investigate dissolved organic matter (DOM) molecular chemistry and diversification processes across 47 surface-water sampling sites in the Yakima River Basin, Washington, USA, during an August 2021 sampling campaign. The package contains analyses of ultrahigh-resolution Fourier transform ion cyclotron resonance mass spectrometry (FTICR-MS), geochemical measurements, geospatial attributes, molecular diversity, and meta-metabolome ecological null models needed to reproduce the main manuscript results. The underlying field data were pulled from exising data packages at https://doi.org/10.15485/1892052 (Fulton et al., 2022) and https://doi.org/10.15485/1898914 (Grieger et al., 2022). For details on how to navigate data packages generated by this project, see https://data.ess-dive.lbl.gov/portals/PNNLRiverCorridorSFA/About. We thank the following organizations for providing access to field locations for sample collection: the United States Forest Service, Washington Department of Fish and Wildlife, Washington Department of Natural Resources, the Confederated Tribes and Bands of the Yakama Nation, and the Cowiche Canyon Conservatory. Research was conducted under Washington State Parks and Recreation Commission Scientific Research Permit #210901. We are grateful to the Yakama Nation Tribal Council and Yakama Nation Fisheries for their collaboration in facilitating sample collection and ensuring data usage aligns with their values and worldview. This data package contains an R-Markdown file for analyses and five folders: (1) Data, (2) Geospatial Data, (3) Supplemental_Files, (5) Figures_pdf, (4) and src. The Data folder contains tabular inputs and derived files used in the manuscript analysis. The Geospatial Data folder contains climate and water-balance, hydrologic, land-cover, population/regional water-use, stream, topographic, and stream-order attribute CSV files. The src folder contains scripts used to process data, run analyses, and generate figures. The Figures_pdf folder contains manuscript figure outputs. The Supplemental_Files folder contains supplemental analysis products. All files are .csv, .pdf, .html, .png, .R, .Rmd, .svg, or .tre. This data package is associated with the rcfsa-RC2-SPS_Null_Modeling repository found at https://github.com/river-corridors-sfa/rcfsa-RC2-SPS_Null_Modeling.

54 ENVIRONMENTAL SCIENCES↗

Dissolution of Plutonium Metal in 8-10 M Nitric Acid

The H-Canyon facility will be used to dissolve Pu metal for subsequent purification and conversion to plutonium dioxide (PuO 2 ) using Phase II of HB-Line. To support the new mission, the development of a Pu metal dissolution flowsheet which utilizes concentrated (8-10 M) nitric acid (HNO 3 ) solutions containing potassium fluoride (KF) is required. Dissolution of Pu metal in concentrated HNO 3 is desired to eliminate the need to adjust the solution acidity prior to purification by anion exchange. The preferred flowsheet would use 8-10 M HNO 3 , 0.015-0.07 M KF, and 0.5-1.0 g/L Gd to dissolve the Pu up to 6.75 g/L. An alternate flowsheet would use 8-10 M HNO 3 , 0.1-0.2 M KF, and 1-2 g/L B to dissolve the Pu. The targeted average Pu metal dissolution rate is 20 mg/min-cm 2 , which is sufficient to dissolve a 'standard' 2250-g Pu metal button in 24 h. Plutonium metal dissolution rate measurements showed that if Gd is used as the nuclear poison, the optimum dissolution conditions occur in 10 M HNO 3 , 0.04-0.05 M KF, and 0.5-1.0 g/L Gd at 112 to 116°C (boiling). These conditions will result in an estimated Pu metal dissolution rate of ~11-15 mg/min-cm 2 and will result in dissolution times of 36-48 h for standard buttons. The recommended minimum and maximum KF concentrations are 0.03 M and 0.07 M, respectively. The maximum KF concentration is dictated by a potential room-temperature Pu-Gd-F precipitation issue at low Pu concentrations. The purpose of the experimental work described in this report was two-fold. Initially a series of screening experiments was performed to measure the dissolution rate of Pu metal as functions of the HNO 3 , KF, and Gd or B concentrations. The objective of the screening tests was to propose optimized conditions for subsequent flowsheet demonstration tests. Based on the rate measurements, this study found that optimal dissolution conditions in solutions containing 0.5-1.0 g/L Gd occurred in 8-10 M HNO 3 with 0.04-0.05 M KF at 112 to 116°C (boiling). The testing also showed that solutions containing 8-10 M HNO 3 , 0.1-0.2 M KF, and 1-2 g/L B achieved acceptable dissolution rates in the same temperature range. To confirm that conditions identified by the dissolution rate measurements for solutions containing Gd or B can be used to dissolve Pu metal up to 6.75 g/L in the presence of Fe, demonstration experiments were performed using concentrations in the optimal ranges. In two of the demonstration experiments using Gd and in one experiment using B, the offgas generation during the dissolution was measured and samples were analyzed for H 2 . The experimental methods used to perform the dissolution rate measurements and flowsheet demonstrations and a discussion of the results are presented.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Oxidation of porous stainless steel supports for metal-supported solid oxide electrolysis cells

Oxidation behavior of porous P434L ferritic stainless steel, used for the fabrication of metal-supported solid oxide electrolysis cells (MS-SOEC), is studied under oxygen-side and steam-side conditions. The impact of oxygen content on the oxygen side and steam:hydrogen ratio on the steam side is determined at 700°C for bare, as-sintered samples. For these conditions, oxidation is more aggressive in the steam-side atmosphere. Oxygen with 3% humidification and steam:hydrogen ratio of 90:10 are selected for further assessment with pre-oxidized, catalyst-coated, and CuMn1·8O4-coated samples. The rapid oxidation at 700°C and breakaway oxidation at 600 °C observed for bare stainless steel in 90:10 steam:hydrogen is mitigated by pre-oxidizing the sample in air before exposure. In oxygen, addition of the catalyst or CuMn 1·8 O 4 coatings moderately increases the oxidation rate, due to consumption of Cr via reaction between the coatings and Cr-oxide scale. In conclusion, the results for ex-situ controlled oxidation are similar to oxidation observed after 1000h operation of a full MS-SOEC. In general, the oxidation behavior at 700°C is found to be acceptable.

08 HYDROGEN↗