Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Water System”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 847 records · Page 47

Multiple biomarkers highlight the importance of water column processes in treatment wetland organic matter cycling

A suite of biomarkers, including amino acids, pigments, and lignin phenols coupled with high resolution mass spectrometry were used to evaluate differences in the sources and fate of organic matter (OM) in Everglades treatment wetlands as a model for OM cycling in shallow water wetlands. Five components of the system (water column particulate organic matter, vertical traps, flocculent material, periphyton, and surface soil) were assessed for OM transformations down-profile (i.e. water column to soil) and between treatment cells dominated by emergent aquatic vegetation (EAV) and submerged aquatic vegetation (SAV), with comparisons to reference sites that resemble historic Everglades conditions. We found that OM cycling is fundamentally different between EAV and SAV wetlands, and that SAV wetlands have some shared characteristics with similar habitats in the Everglades. Other than locations densely populated by Typha spp., water column particulate organic C was derived from microbial/cryptomonad sources, rather than macroscopic sources (vascular plants and algal mats). Bacterial amino acid biomarkers were positively correlated with amino acid degradation indices and organic P (Po), respectively suggesting that microbial abundance is associated with "fresher" OM, and that further investigation into relationships between microbial biomass and Po is warranted. Overall, this multi-biomarker approach can evaluate the relative "freshness" of OM pools, identify sources of OM, and highlight the importance of water column processes in shallow water wetlands.

treatment wetlands, organic matter, Everglades, am↗

Emerging Technologies Review: Water Microgrid

Project 69643 Task 10 - The Air Force Civil Engineer Center has tasked Pacific Northwest National Laboratory with investigating emerging technologies to inform the Air Force’s understanding of the technology and to guide key considerations for implementing technologies that are resilient and alternative sources to the traditional methods used in the Air Force today. This report explores the concept of a water microgrid for deployment at Air Force installations. A water microgrid is a local water system that supplies, treats, and distributes water, with the primary objective to meet mission critical water demand during a disruption of the primary supply. A water microgrid can advance an Air Force installation’s water infrastructure and water resilience by being at the ready for meeting critical missions during a utility outage.

42 ENGINEERING↗

Power Grid Simulation Testbed for Transactive Energy Management Systems

To effectively engage demand-side and distributed energy resources (DERs) for dynamically maintaining the electric power balance, the challenges of controlling and coordinating building equipment and DERs on a large scale must be overcome. Although several control techniques have been proposed in the literature, a significant obstacle to applying these techniques in practice is having access to an effective testing platform. Performing tests at scale using real equipment is impractical, so simulation offers the only viable route to developmental testing at scales of practical interest. Existing power-grid testbeds are unable to model individual residential end-use devices for developing detailed control formulations for responsive loads and DERs. Furthermore, they cannot simulate the control and communications at subminute timescales. To address these issues, this paper presents a novel power-grid simulation testbed for transactive energy management systems. Detailed models of primary home appliances (e.g., heating and cooling systems, water heaters, photovoltaic panels, energy storage systems) are provided to simulate realistic load behaviors in response to environmental parameters and control commands. The proposed testbed incorporates software as it will be deployed, and enables deployable software to interact with various building equipment models for end-to-end performance evaluation at scale.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Modeling Green Roof Potential to Mitigate Urban Flooding in a Chinese City

The Middle and Lower Reaches of the Yangtze River (MLRYR) region, which has humid subtropical climate conditions and unique plum rain season, is characterized by a simultaneous high-frequency urban flooding and reduction in groundwater levels. Retrofitting the existing buildings into green roofs is a promising approach to combat urban flooding, especially for a densely developed city. Here, the application potential of the Green Roof System (GRS) and the Improved Green Roof System (IGRS) designed to divert overflowing water from green roofs to recharge groundwater were analyzed in a densely developed city, Nanchang, China. For the first time, the influence of GRS on the hydraulic condition of Combined Sewage System/Storm Water System (CSS/SWS) is analyzed, which is a direct reflection of the effect of GRS on alleviating urban flooding. The simulation results show that GRS can retain about 41–75% of precipitation in a 2-hour timescale and the flooding volumes in the GRS/IGRS region are 82% and 28% less than those of the Traditional Roof System (TRS) in 10- and 100-yr precipitation events, respectively. In the continuous simulations, GRS also enhances Evapotranspiration (ET), which accounts for 39% of annual precipitation, so that reduces the cumulative surface runoff. Considering the IGRS can provide more hydrological benefits than the GRS under the same climate conditions, we may conclude that the widespread implementation of both the GRS and the IGRS in Nanchang and other densely developed cities in the MLRYR region could significantly reduce surface and peak runoff rates.

54 ENVIRONMENTAL SCIENCES↗

Regenerating Water-Sterilizing Resins

Iodine-dispensing resin can be regenerated after iodine content has been depleted, without being removed from water system. Resin is used to make water potable by killing bacteria, fungi, and viruses. Regeneration technique may be come basis of water purifier for very long space missions. Enough crystalline iodine for multiple regenerations during mission can be stored in one small cartridge. Cartridge could be inserted in waterline as necessary on signal from iodine monitor or timer.

Colombo, G. V.↗

Mitigation of Damage to the International Space Station (ISS) from Water Dumps

The International Space Station (ISS) and Orbiter dump water overboard. This water is from the ISS condensate system, and from the Orbiter s fuel cell (supply side) and wastewater (urine and condensate) systems. Water dumped from either the ISS or Orbiter is a possible source of damage. When water is dumped into a vacuum, some of it flashes into a vapor. The expanding vapor bursts the liquid stream into vapor, and small and large liquid/ice particles. The large liquid/ice particles are approximately 2 mm in diameter and have nominal velocities of approximately 31 Wsec (U.S. Lab) and 50 Wsec (Orbiter). As these liquid/ice particles impact, they can cause mechanical damage due to erosion/pitting of sensitive surfaces, including solar array or radiator surfaces. Solar arrays are of particular concern because of the thin optical coatings on the surface of the cells. The thickness of these coatings is in the range of 1300 to 44000 angstroms. Damage to these coatings can cause degradation of the cells optical characteristics. To mitigate damage from water dumps, the characteristics of the water dumps were studied and an impact code was used to study damage to sensitive surfaces. The results were used to develop the constraints needed to mitigate damage to ISS hardware from Orbiter and U.S. Lab dumps.

Schmidl, William↗

Microbial Challenge Testing of Single Liquid Cathode Feed Water Electrolysis Cells for the International Space Station (ISS) Oxygen Generator Assembly (OGA)

The International Space Station (ISS) Oxygen Generator Assembly (OGA) operational performance may be adversely impacted by microbiological growth and biofilm formation over the electrolysis cell membranes. Biofilms could hinder the transport of water from the bulk fluid stream to the membranes and increase the cell resistance resulting in higher cell voltages and a shorter cell life. A microbial challenge test was performed on duplicate single liquid cathode feed electrolyzer cells to evaluate operational performance with increasing levels of a mixture of five bacteria isolated from ISS and Space Shuttle potable water systems. Baseline performance of the single water electrolysis cells was determined for approximately one month with deionized water. Monthly performance was also determined following each inoculation of the feed tank with 100, 1000, 10,000 and 100,000 cells/ml of the mixed suspension of test bacteria. Water samples from the feed tank and recirculating water loops for each cell were periodically analyzed for enumeration and speciation of bacteria and total organic carbon. While initially a concern, this test program has demonstrated that the performance of the electrolysis cell is not adversely impacted by feed water containing the five species of bacteria tested at a concentration measured as high as 1,000,000 colony forming units (CFU)/ml. This paper presents the methodologies used in the conduct of this test program along with the performance test results at each level of bacteria concentration.

Diderich, Greg S.↗

Microbial Challenge Testing of Single Liquid Cathode Feed Water Electrolysis Cells for the International Space Station (ISS) Oxygen Generator Assembly (OGA)

The International Space Station (ISS) Oxygen Generator Assembly (OGA) operational performance may be adversely impacted by microbiological growth and biofilm formation over the electrolysis cell membranes. Biofilms could hinder the transport of water from the bulk fluid stream to the membranes and increase the cell concentration overpotential resulting in higher cell voltages and a shorter cell life. A microbial challenge test was performed on duplicate single liquid-cathode feed water electrolysis cells to evaluate operational performance with increasing levels of a mixture of five bacteria isolated from ISS and Space Shuttle potable water systems. Baseline performance of the single water electrolysis cells was determined for approximately one month with deionized water. Monthly performance was also determined following each inoculation of the feed tank with 100, 1000, 10,000 and 100,000 cells/ml of the mixed suspension of test bacteria. Water samples from the feed tank and recirculating water loops for each cell were periodically analyzed for enumeration and speciation of bacteria and total organic carbon. While initially a concern, this test program has demonstrated that the performance of the electrolysis cell is not adversely impacted by feed water containing the five species of bacteria tested at a concentration measured as high as 1,000,000 colony forming units (CFU)/ml. This paper presents the methodologies used in the conduct of this test program along with the performance test results at each level of bacteria concentration.

Roy, Robert J.↗

SINGLE PHASE ANALYTICAL MODELS FOR TERRY TURBINE NOZZLE

All BWR RCIC (Reactor Core Isolation Cooling) systems and PWR AFW (Auxiliary Feed Water) systems use Terry turbine, which is composed of the wheel with turbine buckets and several groups of fixed nozzles and reversing chambers inside the turbine casing. The inlet steam is accelerated through the turbine nozzle and impacts on the wheel buckets, generating work to drive the RCIC pump. As part of the efforts to understand the unexpected “self-regulating” mode of the RCIC systems in Fukushima accidents and extend BWR RCIC and PWR AFW operational range and flexibility, mechanistic models for the Terry turbine, based on Sandia National Laboratories’ original work, has been developed and implemented in the RELAP-7 code to simulate the RCIC system. RELAP-7 is a new reactor system code currently under development with the funding support from U.S. Department of Energy. The RELAP-7 code is a fully implicit code and the preconditioned Jacobian-free Newton-Krylov (JFNK) method is used to solve the discretized nonlinear system. This paper presents a set of analytical models for simulating the flow through the Terry turbine nozzles when inlet fluid is pure steam. The implementation of the models into RELAP-7 will be briefly discussed. In the Sandia model, the turbine bucket inlet velocity is provided according to a reduced-order model, which was obtained from a large number of CFD simulations. In this work, we propose an alternative method, using an under-expanded jet model to obtain the velocity and thermodynamic conditions for the turbine bucket inlet. The models include both adiabatic expansion process inside the nozzle and free expansion process out of the nozzle to reach the ambient pressure. The combined models are able to predict the steam mass flow rate and supersonic velocity to the Terry turbine bucket entrance, which are the necessary input conditions for the Terry Turbine rotor model. The nozzle analytical models were validated with experimental data and benchmarked with CFD simulations. The analytical models generally agree well with the experimental data and CFD simulations. The analytical models are suitable for implementation into a reactor system analysis code or severe accident code as part of mechanistic and dynamical models to understand the RCIC behaviors. The cases with two-phase flow at the turbine inlet will be pursued in future work.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Effect of Evaporation on Vapor Space Flammability in DWPF Process Vessels - 20278

The Savannah River Site (SRS) Defense Waste Processing Facility (DWPF) processes liquid high-level waste (HLW) and encapsulates it in glass within stainless-steel containers suitable for safe, long-term storage and disposal. Radiolytic and chemical decomposition of the liquid waste generates hydrogen and other flammable gases creating a hazard. The rate of flammable gas generation increases by an order of magnitude as temperature increases from sub-boiling to boiling. DWPF controls this hazard in process tanks by ensuring a minimum purge flow through each tank's head space. The minimum purge flow rate is established assuming dry air and neglecting evaporation. However, this study determined that steam from boiling in a representative process tank is sufficient to dilute flammable gases and, thereby, preclude flammability. For sub-boiling, water vapor is an insufficient diluent considering hydrogen's lower flammable limit (LFL) in air. However, the upper and lower flammable limits approach each other in a hydrogen-air-water-vapor environment as the water vapor concentration increases. This effect may preclude flammable conditions if water vapor concentration is about 60 volume percent or higher. A saturated, constant-pressure air-water system would achieve 60 volume percent water vapor at 86 deg. C. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Building an Economical and Sustainable Lunar Infrastructure to Enable Human Missions

To enable return of human missions to the surface of the Moon sustainably, a new study was initiated to assess the feasibility of developing an evolvable, economical and sustainable lunar surface infrastructure using a public-private partnerships approach. This approach would establish partnerships between NASA and private industry to mutually develop lunar surface infrastructure capabilities to support robotic missions initially and later evolve to full-scale commercial infrastructure services in support of human missions. These infrastructure services may range from power systems, communication and navigation systems, thermal management systems, mobility systems, water and propellant production to life support systems for human habitats. The public-private partnerships approach for this study leverages best practices from NASA’s Commercial Orbital Transportation Services (COTS) program which introduced an innovative and economical approach for partnering with industry to develop commercial cargo transportation services to the International Space Station (ISS). In this approach, NASA and industry partners shared cost and risk throughout the development phase which led to dramatic reduction in development and operations costs of these transportation services. Following this approach, a Lunar COTS concept was conceived to develop cost-effective surface infrastructure capabilities in partnership with industry to provide economical, operational services for small-scale robotic missions. As a result, a self-contained lunar infrastructure system with power, thermal, communication and navigation elements was conceptually designed to increase capability, extend mission duration and reduce cost of small-scale robotic missions. To support human missions, this work has now been extended to analyze full-scale lunar infrastructure systems. This infrastructure system should have capabilities to support human missions from a few days to several months with minimal maintenance and replacement of parts. This infrastructure system should also maximize the use of existing lunar resources, such as, oxygen from regolith, water from ice deposits at the poles, and use of metals, such as iron and aluminum, from lunar regolith. The plan includes a buildup of these capabilities using a phased-development approach that will eventually lead to operational infrastructure services. By partnering with industry to develop and operate the infrastructure services using the COTS model, this plan should also result in significant cost savings and increased reliability. This paper will describe the Lunar COTS concept goals, objectives and approach for developing an evolvable, economical and sustainable human lunar infrastructure as well as the challenges and opportunities for development.

Zuniga, Allison↗

Effective Thermal Conductivity of an Aluminum Foam + Water Two Phase System

This study examined the effect of volume fraction and pore size on the effective thermal conductivity of an aluminum foam and water system. Nine specimens of aluminum foam representing a matrix of three volume fractions (4-8% by vol.) and three pore sizes (2-4 mm) were tested with water to determine relationships to the effective thermal conductivity. It was determined that increases in volume fraction of the aluminum phase were correlated to increases in the effective thermal conductivity. It was not statistically possible to prove that changes in pore size of the aluminum foam correlated to changes in the effective thermal conductivity. However, interaction effects between the volume fraction and pore size of the foam were statistically significant. Ten theoretical models were selected from the published literature to compare against the experimental data. Models by Asaad, Hadley, and de Vries provided effective thermal conductivity predictions within a 95% confidence interval.

Moskito, John↗

Substrate Matters: Ionic Silver Alters Lettuce Growth, Nutrient Uptake, and Root Microbiome in a Hydroponics System

Ionic silver (Ag+) is being investigated as a residual biocide for use in NASA spacecraft potable water systems on future crewed missions. This water will be used to irrigate future spaceflight crop production systems. We have evaluated the impact of three concentrations (31 ppb, 125 ppb, and 500 ppb) of ionic silver biocide solutions on lettuce in an arcillite (calcinated clay particle substrate) and hydroponic (substrate-less) growth setup after 28 days. Lettuce plant growth was reduced in the hydroponic samples treated with 31 ppb silver and severely stunted for samples treated at 125 ppb and 500 ppb silver. No growth defects were observed in arcillite-grown lettuce. Silver was detectable in the hydroponic-grown lettuce leaves at each concentration but was not detected in the arcillite-grown lettuce leaves. Specifically, when 125 ppb silver water was applied to a hydroponics tray, Ag+ was detected at an average amount of 7 μg/g (dry weight) in lettuce leaves. The increase in Ag+ corresponded with a decrease in several essential elements in the lettuce tissue (Ca, K, P, S). In the arcillite growth setup, silver did not impact the plant root zone microbiome in terms of alpha diversity and relative abundance between treatments and control. However, with increasing silver concentration, the alpha diversity increased in lettuce root samples and in the water from the hydroponics tray samples. The genera in the hydroponic root and water samples were similar across the silver concentrations but displayed different relative abundances. This suggests that ionic silver was acting as a selective pressure for the microbes that colonize the hydroponic water. The surviving microbes likely utilized exudates from the stunted plant roots as a carbon source. Analysis of the root-associated microbiomes in response to silver showed enrichment of metagenomic pathways associated with alternate carbon source utilization, fatty-acid synthesis, and the ppGpp (guanosine 3′-diphosphate 5′-diphosphate) stringent response global regulatory system that operates under conditions of environmental stress. Nutrient solutions containing Ag+ in concentrations greater than 31 ppb in hydroponic systems lacking cation-exchange capacity can severely impact crop production due to stunting of plant growth.

lettuce↗

Building an Economical and Sustainable Lunar Infrastructure to Enable Human Lunar Missions

To enable return of human missions to the surface of the Moon sustainably, a new study was initiated to assess the feasibility of developing an evolvable, economical and sustainable lunar surface infrastructure using a public-private partnerships approach. This approach would establish partnerships between NASA and private industry to mutually develop lunar surface infrastructure capabilities to support robotic missions initially and later evolve to full-scale commercial infrastructure services in support of human missions. These infrastructure services may range from power systems, communication and navigation systems, thermal management systems, mobility systems, water and propellant production to life support systems for human habitats. The public-private partnerships approach for this study leverages best practices from NASA's Commercial Orbital Transportation Services (COTS) program which introduced a new innovative and economical approach for partnering with industry to develop commercial cargo transportation services to the International Space Station (ISS). In this approach, NASA and industry partners shared cost and risk throughout the development phase which led to dramatically reducing development and operations costs of these transportation services. Following this approach, a Lunar COTS concept was conceived to follow this model and gradually develop cost-effective surface infrastructure capabilities in partnership with industry to provide economical, operational services for small-scale robotic missions. To support human missions, this work has now been extended to analyze full-scale lunar infrastructure systems. This infrastructure system will have capabilities to support human missions from a few days to several months and will also maximize the use of existing lunar resources, such as, water from ice deposits at the lunar poles. The plan includes a gradual buildup of these capabilities using a phased-development approach that will eventually lead to operational infrastructure services. By partnering with industry to develop and operate the infrastructure services using the COTS model, this plan will also result in significant cost savings, reduced risk and increased reliability. This paper will describe the Lunar COTS concept goals, objectives and approach for developing an evolvable, economical and sustainable human lunar infrastructure as well as the challenges and opportunities for development.

Lunar Surface Systems↗

Hydrogen isotope fractionation in the system brucite-water ± NaCl to elevated temperatures and pressures: Implications for the isotopic property of NaCl fluids under geologic conditions

According to the article, a series of hydrothermal experiments have been conducted to determine equilibrium D/H fractionations between brucite and water as a function of temperature (200-600 °C), pressure (2.1-800 MPa), and dissolved NaCl (0-5 molal or 0-22.6 wt%). Along with our previous study, a total of 39 data points show that pressure and dissolved NaCl both increase the D/H fractionation factor at a given temperature. Theoretical treatment allowed a first direct comparison of experimental and theoretical results of brucite-water D/H fractionation at a zero pressure limit. After correcting the pressure effects on brucite D/H partition function ratios (β-factor), the isotope effects of pressure and dissolved NaCl on the D/H β-factor of water were for the first time rigorously evaluated. There is a good linear relationship between the D/H β-factor of the aqueous NaCl solutions and their densities of at a given temperature. A good, pseudo-linear relationship observed between the density of aqueous NaCl solutions and the maximum intensity of the asymmetric OH vibrational frequency of water in turn suggests that this frequency is a fundamental property that determines the β-factor of water at elevated temperatures and pressures. Our study suggests that the density of aqueous solutions (ρ aq-soln ) could be used as a primary parameter to predict the effects of pressure and NaCl compositions on the β-factor of water under geologic conditions encountered in the crust and upper mantle:Δ10 3 1n β wat /Δρ aq-soln = -0.0111 (±0.0012), where Δ is a difference in the value of 10 3 In β wat or ρ aq-soln , and ρ aq-soln in kg m -3 .

bio-inspired, mechanical behavior, carbon sequestr↗

System and method of water purification utilizing an ionomer membrane

A water purification system utilizes an ionomer membrane and mild vacuum to draw water from source water through the membrane. A water source may be salt water or a contaminated water source. The water drawn through the membrane passes across the condenser chamber to a condenser surface where it is condensed into purified water. The condenser surface may be metal or any other suitable surface and may be flat or pleated. In addition, the condenser surface may be maintained at a lower temperature than the water on the water source side of the membrane. The ionomer membrane may be configured in a cartridge, a pleated or flat plate configuration. A latent heat loop may be configured to carry the latent heat of vaporization from the condenser back to the water source side of the ionomer membrane. The source water may be heated by a solar water heater.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

System and method of water purification utilizing an ionomer membrane

A water purification system utilizes an ionomer membrane and mild vacuum to draw water from source water through the membrane. A water source may be salt water or a contaminated water source. The water drawn through the membrane passes across the condenser chamber to a condenser surface where it is condensed into purified water. The condenser surface may be metal or any other suitable surface and may be flat or pleated. In addition, the condenser surface may be maintained at a lower temperature than the water on the water source side of the membrane. The ionomer membrane may be configured in a cartridge, a pleated or flat plate configuration. A latent heat loop may be configured to carry the latent heat of vaporization from the condenser back to the water source side of the ionomer membrane. The source water may be heated by a solar water heater.

Bahar, Bamdad↗