Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “VOLT”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 847 records · Page 47

Exploring the cell: Sodium (beta-alumina) cupric chloride - Aluminum chloride - Sodium chloride between 136 and 200 C

Experiments were done with a molten-salt catholyte (initially CuCl2 in AlCl3-NaCl) separated from molten Na by beta alumina. The open-circuit reduction potentials were 4.3 and 3 volts for Cu++ and Cu+, respectively. High polarization and nonrechargeability characterized the cell's operation. The cell's ohmic resistance during discharge was higher than what would be expected from only the ionic resistance of the beta-alumina.

Miller, R. O.↗

The 7.5 kW solar array simulator

A high power solar array simulator capable of providing the input power to simultaneously operate two 30 cm diameter ion thruster power processors was designed, fabricated, and tested. The maximum power point is set to between 150 and 7500 watts representing an open circuit voltage from 50 to 300 volts and a short circuit current from 4 to 36 amps. Illuminated solar cells are used as the control element to provide a true solar cell characteristic and permit the option of simulating changes in this characteristic due to variations in solar intensity and/or temperature of the solar array. This is accomplished by changing the illumination and/or temperature of the control cells. The response of the output to a step change in load closely approximates that of an actual solar array.

Robson, R. R.↗

Space Tug Avionics Definition Study. Volume 5: Cost and Programmatics

The baseline avionics system features a central digital computer that integrates the functions of all the space tug subsystems by means of a redundant digital data bus. The central computer consists of dual central processor units, dual input/output processors, and a fault tolerant memory, utilizing internal redundancy and error checking. Three electronically steerable phased arrays provide downlink transmission from any tug attitude directly to ground or via TDRS. Six laser gyros and six accelerometers in a dodecahedron configuration make up the inertial measurement unit. Both a scanning laser radar and a TV system, employing strobe lamps, are required as acquisition and docking sensors. Primary dc power at a nominal 28 volts is supplied from dual lightweight, thermally integrated fuel cells which operate from propellant grade reactants out of the main tanks.

Source record↗

Ionizing mechanisms in a cesium plasma irradiated with a ruby laser

A cesium filled diode--laser plasmadynamic converter was built to investigate the feasibility of converting laser energy to electrical energy at large power levels. Experiments were performed with a pulsed ruby laser to determine the quantity of electrons and cesium ions generated per pulse of laser beam and to determine the output voltage. A current density as high as 200 amp/sq cm from a spot of approximately 1 sq mm area and an open circuit voltage as high as 1.5 volts were recorded. A qualitative theory was developed to explain these results. In the operation of the device, the laser beam evaporates some of the cesium and ionizes the cesium gas. A dense cesium plasma is formed to absorb further the laser energy. Results suggest that the simultaneous absorption of two ruby laser photons by the cesium atoms plays an important role in the initial ionization of cesium. Inverse bremsstrahlung absorption appears to be the dominant mechanism in subsequent processes. Recombinations of electrons and cesium ions appear to compete favorably with the simultaneous absorption of two photons.

Shimada, K.↗

Evaluation program for secondary spacecraft cells: Initial evaluation tests of Gulton Industries, Incorporated, 9.0 ampere-hour nickel-cadmium spacecraft cells with auxiliary electrodes for the small astronomy Satellite (SAS-C)

An evaluation test program was conducted to insure that all cells put into the life cycle program are of high quality by the screening of cells found to have electrolyte leakage, internal shorts, low capacity, or inability of any cell to recover its open-circuit voltage above 1.150 volts during the internal short test. Tests and results are described.

Harkness, J. D.↗

Evaluation program for secondary spacecraft cells: Initial evaluation tests of General Electric Company 6.0 ampere-hour nickel-cadmium spacecraft cells for the Improved Tiros Operational Satellite (ITOS)

Quality control measures for Ni-Cd spacecraft cells were analyzed. Cells were examined for electrolyte leakage, internal shorts, low capacity, or inability of any cell to recover its open circuit voltage above 1.50 volts during the internal short test. Test results are given in tabular form.

Harkness, J. D.↗

Accelerated life test of sputtering and anode deposit spalling in a small mercury ion thruster

Tantalum and molybdenum sputtered from discharge chamber components during operation of a 5 centimeter diameter mercury ion thruster adhered much more strongly to coarsely grit blasted anode surfaces than to standard surfaces. Spalling of the sputtered coating did occur from a coarse screen anode surface but only in flakes less than a mesh unit long. The results were obtained in a 200 hour accelerated life test conducted at an elevated discharge potential of 64.6 volts. The test approximately reproduced the major sputter erosion and deposition effects that occur under normal operation but at approximately 75 times the normal rate. No discharge chamber component suffered sufficient erosion in the test to threaten its structural integrity or further serviceability. The test indicated that the use of tantalum-surfaced discharge chamber components in conjunction with a fine wire screen anode surface should cure the problems of sputter erosion and sputtered deposits spalling in long term operation of small mercury ion thrusters.

Power, J. L.↗

Special report: Occlusive cuff controller

A mechanical occlusive cuff controller suitable for blood flow experiments in space shuttle flights is described. The device requires 115 volt ac power and a pressurized gas source. Two occluding cuff pressures (30 and 50 mmHg) are selectable by a switch on the front panel. A screw driver adjustment allows accurate cuff pressurization levels for under or oversized limbs. Two pressurization cycles (20 second and 2 minutes) can be selected by a front panel switch. Adjustment of the timing cycles is also available through the front panel. A pushbutton hand switch allows remote start of the cuff inflation cycle. A stop/reset switch permits early termination of the cycle and disabling of the controller to prevent inadvertent reactivation. Pressure in the cuff is monitored by a differential aneroid barometer. In addition, an electrocardiogram trigger circuit permits the initiation of the pressurization cycle by an externally supplied ECG cycle.

Baker, J. T.↗

Two-watt radioisotope power generators for underwater applications

Materials and design considerations are discussed for a low-cost, reliable radio-isotope-fueled thermoelectric generator for use in an undersea application. Plutonium has been selected as fuel, and the generator has to meet design goals of 2 watts after 20 years with a direct output voltage of 6-8 volts. The pressed and sintered form of Bi2Te3 appears to be the most appropriate thermoelectric material. Both fibrous and multilayer foil insulation could be used with proper processing and quality control, but there is less risk with fibrous type insulation. Min-K 1400 is recommended with a nitrogen cover gas. The heat source recommended is a three-layer capsule using T-111 for both the liner and strength member with an outer liner of Hastelloy-C.

Caputo, R. S.↗

Field-aligned auroral electron fluxes

Out of a series of five auroral sounding rocket flights, electron fluxes in three of the flights were observed to be sharply field-aligned. The electrons were detected with an array of electrostatic analyzers making 50-point spectral samples from 0 to 15 keV. The field-aligned fluxes resulted in a peak in the spectrum at a lower energy than that of another monoenergetic peak in the spectrum seen consistently when it was conjugate to bright auroral forms giving multiply peaked spectra. The field-aligned peak in the spectrum is apparently a phenomenon distinct from the isotropic peak and was observed to occur at various times in the energy range from a few hundred electron volts to 5 keV. The field-aligned electrons were highly collimated, having pitch angles less than 20 deg and at times less than 10 deg. The high degree of field alignment and the monoenergetic character support the model that these events can be attributed to relatively cool plasma falling through an electric potential at altitudes not too far removed from the rocket.

Arnoldy, R. L.↗

Properties of the wake of small Langmuir probes on sounding rockets

Split Langmuir probes have been used to study the near wake of small Langmuir probes on sounding rockets. Experiments have been performed on two rocket flights using planar disk and cylindrical geometries, and the results are presented. Significant wake perturbations in plasma density and temperature were found due to the probe body itself, even though the probes were of the order of or smaller than the Debye length. The largest effects of the wake are seen in the electron collection characteristics of the probe. The wake of small probes show apparent magnetic field aligned structure, even though the probes were much smaller than the ion gyroradius. On one flight, a space charge potential large enough to substantially alter photoemission, -3.5 volts, was observed.

Bering, E. A.↗

A multichannel biotelemetry transmitter utilizing a PCM subcarrier

Making use of the currently available integrated circuits, a miniature PCM telemetry system operating from one miniature 9-volt battery and drawing less than 5 milliamps has been constructed. The use of this PCM telemetry signal not only provides accurate data transmission, but requires a minimum of RF bandwidth. The serial format that results from multiplexing the input data allows the use of a single channel recorder with its cost savings over a multichannel tape recorder. An additional benefit of the PCM encoding is that the data is in digital format and is directly suitable for computer use.

Fryer, T. B.↗

Spacecraft charging control demonstration at geosynchronous altitude

ATS-6, which was launched on May 30, 1974, has now completed its first eclipse season. Potentials as great as 11,000 volts were observed between the spacecraft and ambient plasma. Both ATS-5 and 6 have ion engine experiments onboard. These experiments have been used to clamp the spacecraft potential slightly negative when emitting an ion beam and momentarily discharge the spacecraft when only operating the ion engine's neutralizing electron source. Descriptions of the neutralizer's operation and their effect on potential are presented. In addition, spacecraft charging data for ATS-5 and 6 are presented and correlated over the same eclipse season.

Bartlett, R. O.↗

Design considerations in the creation and maintenance of electrostatic cleanliness for solar electrically propelled spacecraft

Charge build-up on spacecraft surfaces and resulting zones of electrostatic contamination have been examined for electrically active and electrically passive spacecraft with both conducting and dielectric surface materials, illuminated and nonilluminated surface conditions, and for both inclusion and neglect of free charge effects from photocurrents and ambient space plasma particles. Techniques for measurement and reduction of electrostatic contamination zone extent have been developed for spacecraft with charge release capability. Indicated limitations for contamination cleanup are about 1 volt potential variation from spacecraft to ambient plasma. Bandwidths of electrostatic monitoring and clamping devices extend to several hundred kilohertz for both DC and 'broadband' AC electrostatic cleanliness.

Sellen, J. M., Jr.↗

Cosmic ray particle dosimetry and trajectory tracing

Five pocket mice (Perognathus longimembris) were flown on Apollo XVII, each with a solid-state (plastic) nuclear track detector implanted beneath its scalp. The subscalp detectors were sensitive to HZE cosmic ray particles with a LET greater than or approximately equal to 0.15 million electron volts per micrometer (MeV/micron). A critical aspect of the dosimetry of the experiment involved tracing individual particle trajectories through each mouse head from particle tracks registered in the individual subscalp detectors, thereby establishing a one-to-one correspondence between a trajectory location in the tissue and the presence or absence of a lesion. The other major aspect was the identification of each registered particle. An average of 16 particles with Z greater than or equal to 6 and 2.2 particles with Z greater than or equal to 20 were found per detector. The track density, 29 tracks/sq cm, when adjusted for detection volume, was in agreement with the photographic emulsion data from an area dosimeter located next to the flight package.

Cruty, M. R.↗

The cesium bombardment engine north-south stationkeeping experiment on ATS-6

Two one-millipound-thrust cesium-bombardment ion thrusters have been developed and integrated on the ATS-F spacecraft for the purpose of demonstrating compatible north-south stationkeeping of a synchronous communication satellite. In addition to the two flight units, an identical system is undergoing extended testing on the ground to demonstrate operating lifetime. On July 17, 1974, approximately 50 days after launch, preliminary operation of one of the thrusters was begun. Completely successful operation was achieved on the first run. In addition to verifying operation, the principal accomplishments were the demonstration of a total absence of interference with the complete array of spacecraft-to-ground communication links and the verification of the predicted spacecraft operating potential of approximately -10 volts. Subsequent attempts to operate the same thruster have not been successful and an investigation of possible explanations is underway.

Hunter, R. E.↗

Efficiency and weight of voltage multiplier type ultra lightweight d.c.-d.c. converters

This paper presents an analytical and experimental study of a capacitor-diode voltage multiplier without a transformer which offers the possibility of high efficiency with light weight. Dc-dc conversion efficiencies of about 94% were achieved at output powers of 150 watts at 1000 volts using 8x multiplication. A detailed identification of losses was made, including forward drop losses in component, switching losses, reverse junction capacitance charging losses, and charging losses in the main ladder capacitors.

Harrigill, W. T., Jr.↗

Effects of high doping levels on silicon solar cell performance

Open-circuit voltages measured in silicon solar cells made from 0.01 ohm-cm material are 150 mV lower than voltages calculated from simple diffusion theory and cannot be explained by poor diffusion lengths or surface leakage currents. An analytical study was made to determine whether high doping effects, which increase the intrinsic carrier concentration, could account for the low observed voltages and to determine the limits on voltage and efficiency imposed by high doping effects. The results indicate that the observed variation of voltage with base resistivity is predicted by these effects. A maximum efficiency of 19% (AMO) and a voltage of 0.7 volts were calculated for 0.1 ohm-cm cells assuming an optimum diffused layer impurity profile.

Godlewski, M. P.↗